www.cadfamily.com The document is forAspen HYSYS Operations Guide EMail:cadserv21@hotmail.com study only,if tort to your rights,please inform us,we will delete www.c The doVersion Number: 7.0 Copyright (c) 1981-2008 by Aspen Technology, Inc. All rights reserved. Aspen HYSYS, Aspen HYSYS Petroleum Refining, Aspen Flare System Analyzer, and Aspen HYSYS Pipeline Hydraulics, are trademarks or registered trademarks of Aspen Technology, Inc., Burlington, MA. All other brand and product names are trademarks or registered trademarks of their respective companies. This manual is intended as a guide to using AspenTech’s software. This documentation contains AspenTech proprietary and confidential information and may not be disclosed, used, or copied without the prior consent of AspenTech or as set forth in the applicable license agreement. Users are solely responsible for the proper use of the software and the application of the results obtained. Although AspenTech has tested the software and reviewed the documentation, the sole warranty for the software may be found in the applicable license agreement between AspenTech and the user. ASPENTECH MAKES NO WARRANTY OR REPRESENTATION, EITHER EXPRESSED OR IMPLIED, WITH RESPECT TO THIS DOCUMENTATION, ITS QUALITY, PERFORMANCE, MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE. Aspen Technology, Inc. 200 Wheeler Road Burlington, MA 01803-5501 USA Phone: (781) 221-6400 Website http://www.aspentech.comadfamily.com EMail:cadserv21@hotmail.com cument is for study only,if tort to your rights,please inform us,we will delete www.c The doadfamily.com EMail:cadserv21@hotmail.com cument is for study only,if tort to your rights,please inform us,we will delete v ww ThTechnical Supportv Online Technical Support Center ........................................................ vi Phone and E-mail .............................................................................. vii w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete vi ww ThOnline Technical Support Center AspenTech customers with a valid license and software maintenance agreement can register to access the Online Technical Support Center at: http://support.aspentech.com You use the Online Technical Support Center to: • Access current product documentation • Search for technical tips, solutions, and frequently asked questions (FAQs) • Search for and download application examples • Search for and download service packs and product updates • Submit and track technical issues • Send suggestions • Report product defects • Review known deficiencies and defects Registered users can also subscribe to our Technical Support e- Bulletins. These e-Bulletins proactively alert you to important technical support information such as: • Technical advisories • Product updates and releasesvi w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete vii ww ThPhone and E-mail Customer support is also available by phone, fax, and e-mail for customers who have a current support contract for their product(s). Toll-free charges are listed where available; otherwise local and international rates apply. For the most up-to-date phone listings, please see the Online Technical Support Center at: http://support.aspentech.comvii w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete viii ww Thviii w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete www The 1 Table of Contents Technical Support..................................................... v Online Technical Support Center ............................vi Phone and E-mail................................................ vii 1 Operations Overview ............................................1-1 1.1 Engineering..................................................... 1-2 1.2 Operations ...................................................... 1-6 1.3 Common Property Views ..................................1-14 2 Column Operations ...............................................2-1 2.1 Column Subflowsheet ....................................... 2-4 2.2 Column Theory ...............................................2-11 2.3 Column Installation .........................................2-25 2.4 Column Property View......................................2-37 2.5 Column Specification Types ............................2-121 2.6 Column Stream Specifications.........................2-135 2.7 Column-Specific Operations ............................2-136 2.8 Running the Column ......................................2-193 2.9 Column Troubleshooting.................................2-196 2.10 References ...................................................2-201 3 Electrolyte Operations ..........................................3-1 3.1 Introduction .................................................... 3-2 3.2 Crystallizer Operation ....................................... 3-4 3.3 Neutralizer Operation.......................................3-10 3.4 Precipitator Operation......................................3-18 4 Heat Transfer Operations .....................................4-1 4.1 Air Cooler........................................................ 4-3 4.2 Cooler/Heater .................................................4-45 4.3 Fired Heater (Furnace).....................................4-62.cadfamily.com EMail:cadserv21@hotmail.com document is for study only,if tort to your rights,please inform us,we will delete www The 2 4.4 Heat Exchanger4-89 4.5 LNG4-163 4.6 References4-216 5 Logical Operations5-1 5.1 Adjust5-4 5.2 Balance5-20 5.3 Boolean Operations5-29 5.4 Control Ops5-57 5.5 Digital Point5-180 5.6 Parametric Unit Operation5-190 5.7 Recycle5-199 5.8 Selector Block5-219 5.9 Set5-226 5.10 Spreadsheet5-229 5.11 Stream Cutter5-248 5.12 Transfer Function5-265 5.13 Common Options5-282 6 Piping Operations6-1 6.1 Compressible Gas Pipe6-3 6.2 Liquid-liquid Hydrocyclone6-16 6.3 Mixer6-35 6.4 Pipe Segment6-43 6.5 Relief Valve6-111 6.6 Tee6-124 6.7 Valve6-133 6.8 References6-178 7 Optimizer Operation7-1 7.1 Optimizer7-2 7.2 Original Optimizer7-5 7.3 Hyprotech SQP Optimizer7-18 7.4 MDC Optim7-23 7.5 DataRecon7-24 7.6 Selection Optimization7-24 7.7 Example: Original Optimizer7-35 7.8 Example: MNLP Optimization7-44 7.9 References7-59 8 Reactor Operations8-1 8.1 CSTR/General Reactors8-3.cadfamily.com EMail:cadserv21@hotmail.com document is for study only,if tort to your rights,please inform us,we will delete www The 3 8.2 CSTR/General Reactors Property View8-5 8.3 Yield Shift Reactor8-42 8.4 Plug Flow Reactor8-74 8.5 Plug Flow Reactor (PFR) Property View8-78 9 Rotating Operations9-1 9.1 Centrifugal Compressor or Expander9-2 9.2 Reciprocating Compressor9-48 9.3 Pump9-63 9.4 References9-95 10 Separation Operations10-1 10.1 Component Splitter10-2 10.2 Separator, 3-Phase Separator, & Tank10-12 10.3 Shortcut Column10-51 10.4 References10-56 11 Solid Separation Operations11-1 11.1 Baghouse Filter11-3 11.2 Cyclone11-8 11.3 Hydrocyclone11-16 11.4 Rotary Vacuum Filter11-22 11.5 Simple Solid Separator11-29 12 Streams12-1 12.1 Energy Stream Property View12-2 12.2 Material Stream Property View12-5 13 Subflowsheet Operations13-1 13.1 Introduction13-2 13.2 Subflowsheet Property View13-3 14 Utilities14-1 14.1 Introduction14-4 14.2 Boiling Point Curves14-7 14.3 CO2 Solids14-14 14.4 Cold Properties14-17 14.5 Composite Curves Utility14-23 14.6 Critical Properties14-29 14.7 Data Reconciliation Utility14-33 14.8 Derivative Utility14-59 14.9 Dynamic Depressuring14-60 14.10Envelope Utility14-87.cadfamily.com EMail:cadserv21@hotmail.com document is for study only,if tort to your rights,please inform us,we will delete www The 4 14.11FRI Tray Rating Utility14-110 14.12Hydrate Formation Utility14-126 14.13Master Phase Envelope Utility14-142 14.14Parametric Utility14-145 14.15Pipe Sizing14-172 14.16Property Balance Utility14-176 14.17Property Table14-187 14.18Tray Sizing14-196 14.19User Properties14-231 14.20Vessel Sizing14-235 14.21References14-241 Index1-1.cadfamily.com EMail:cadserv21@hotmail.com document is for study only,if tort to your rights,please inform us,we will delete Operations Overview 1-1 ww Th1 Operations Overview1-1 1.1 Engineering.................................................................................... 2 1.2 Operations ..................................................................................... 6 1.2.1 Installing Operations................................................................. 6 1.2.2 Unit Operation Property View ..................................................... 9 1.3 Common Property Views.............................................................. 14 1.3.1 Graph Control Property View.................................................... 14 1.3.2 Heat Exchanger Page.............................................................. 15 1.3.3 Holdup Page .......................................................................... 23 1.3.4 HoldUp Property View ............................................................. 24 1.3.5 Notes Page/Tab...................................................................... 27 1.3.6 Nozzles Page ......................................................................... 29 1.3.7 Stripchart Page/Tab ................................................................ 30 1.3.8 User Variables Page/Tab .......................................................... 32 1.3.10 Worksheet Tab ..................................................................... 36 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 1-2 Engineering ww Th1.1 Engineering As explained in the HYSYS User Guide and HYSYS Simulation Basis guide, HYSYS has been uniquely created with respect to the program architecture, interface design, engineering capabilities, and interactive operation. The integrated steady state and dynamic modeling capabilities, where the same model can be evaluated from either perspective with full sharing of process information, represent a significant advancement in the engineering software industry. The various components that comprise HYSYS provide an extremely powerful approach to steady state process modeling. At a fundamental level, the comprehensive selection of operations and property methods allows you to model a wide range of processes with confidence. Perhaps even more important is how the HYSYS approach to modeling maximizes your return on simulation time through increased process understanding. The key to this is the Event Driven operation. By using a ‘degrees of freedom’ approach, calculations in HYSYS are performed automatically. HYSYS performs calculations as soon as unit operations and property packages have enough required information. Any results, including passing partial information when a complete calculation cannot be performed, is propagated bi- directionally throughout the flowsheet. What this means is that you can start your simulation in any location using the available information to its greatest advantage. Since results are available immediately - as calculations are performed - you gain the greatest understanding of each individual aspect of your process.1-2 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Operations Overview 1-3 ww ThThe multi-flowsheet architecture of HYSYS is vital to this overall modeling approach. Although HYSYS has been designed to allow the use of multiple property packages and the creation of pre- built templates, the greatest advantage of using multiple flowsheets is that they provide an extremely effective way to organize large processes. By breaking flowsheets into smaller components, you can easily isolate any aspect for detailed analysis. Each of these sub-processes is part of the overall simulation, automatically calculating like any other operation. The design of the HYSYS interface is consistent, if not integral, with this approach to modeling. Access to information is the most important aspect of successful modeling, with accuracy and capabilities accepted as fundamental requirements. Not only can you access whatever information you need when you need it, but the same information can be displayed simultaneously in a variety of locations. Just as there is no standardized way to build a model, there is no unique way to look at results. HYSYS uses a variety of methods to display process information - individual property views, the PFD, Workbook, Databook, graphical Performance Profiles, and Tabular Summaries. Not only are all of these display types simultaneously available, but through the object-oriented design, every piece of displayed information is automatically updated whenever conditions change. The inherent flexibility of HYSYS allows for the use of third party design options and custom-built unit operations. These can be linked to HYSYS through OLE Extensibility. This Engineering section covers the various unit operations, template and column subflowsheet models, optimization, utilities, and dynamics. Since HYSYS is an integrated steady state and dynamic modeling package, the steady state and dynamic modeling capabilities of each unit operation are described successively, thus illustrating how the information is shared between the two approaches. In addition to the Physical operations, there is a chapter for Logical operations, which are the operations that do not physically perform heat and material balance calculations, but rather, impart logical relationships between the elements that make up your process.1-3 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 1-4 Engineering ww ThThe following is a brief definition of categories used in this volume: Integrated into the steady state modeling is multi-variable optimization. Once you have reached a converged solution, you can construct virtually any objective function with the Optimizer. There are five available solution algorithms for both unconstrained and constrained optimization problems, with an automatic backup mechanism when the flowsheet moves into a region of non-convergence. HYSYS offers an assortment of utilities which can be attached to process streams and unit operations. These tools interact with the process model and provide additional information. In this guide, each operation is explained in its respective chapters for steady state and dynamic modeling. A separate guide has been devoted to the principles behind dynamic modeling. HYSYS is the first simulation package to offer dynamic flowsheet modeling backed up by rigorous property package calculations. HYSYS has a number of unit operations, which can be used to assemble flowsheets. By connecting the proper unit operations Term Definition Physical Operations Governed by thermodynamics and mass/energy balances, as well as operation-specific relations. Logical Operations The Logical Operations presented in this volume are primarily used in Steady State mode to establish numerical relationships between variables. Examples include the Adjust and Recycle. There are, however, several operations such as the Spreadsheet and Set operation which can be used in Steady State and Dynamic mode. Subflowsheets You can define processes in a subflowsheet, which can then be inserted as a “unit operation” into any other flowsheet. You have full access to the operations normally available in the main flowsheet. Columns Unlike the other unit operations, the HYSYS Column is contained within a separate subflowsheet, which appears as a single operation in the main flowsheet. The HYSYS Dynamics license is required to use the features in the HYSYS dynamics mode. Refer to Section 1.6 - HYSYS Dynamics in the HYSYS Dynamic Modeling guide for more information.1-4 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Operations Overview 1-5 ww Thand streams, you can model a wide variety of oil, gas, petrochemical, and chemical processes. Included in the available operations are those which are governed by thermodynamics and mass/energy balances, such as Heat Exchangers, Separators, and Compressors, and the logical operations like the Adjust, Set, and Recycle. A number of operations are also included specifically for dynamic modeling, such as the Controller, Transfer Function Block, and Selector. The Spreadsheet is a powerful tool, which provides a link to nearly any flowsheet variable, allowing you to model “special” effects not otherwise available in HYSYS. In modeling operations, HYSYS uses a Degrees of Freedom approach, which increases the flexibility with which solutions are obtained. For most operations, you are not constrained to provide information in a specific order, or even to provide a specific set of information. As you provide information to the operation, HYSYS calculates any unknowns that can be determined based on what you have entered. For instance, consider the Pump operation. If you provide a fully-defined inlet stream to the pump, HYSYS immediately passes the composition and flow to the outlet. If you then provide a percent efficiency and pressure rise, the outlet and energy streams is fully defined. If, on the other hand, the flowrate of the inlet stream is undefined, HYSYS cannot calculate any outlet conditions until you provide three parameters, such as the efficiency, pressure rise, and work. In the case of the Pump operation, there are three degrees of freedom, thus, three parameters are required to fully define the outlet stream. All information concerning a unit operation can be found on the tabs and pages of its property view. Each tab in the property view contains pages which pertain to the unit operation, such as its stream connections, physical parameters (for example, pressure drop and energy input), or dynamic parameters such as vessel rating and valve information.1-5 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 1-6 Operations ww Th1.2 Operations 1.2.1 Installing Operations There are a number of ways to install unit operations into your flowsheet. The operations which are available depends on where you are currently working (main flowsheet, template subflowsheet or column subflowsheet). If you are in the main flowsheet or template environments, all operations are available, except those associated specifically with the column, such as reboilers and condensers. A smaller set of operations is available within the column subflowsheet. The two primary areas from which you can install operations are the UnitOps property view and the Object Palette. The operations are divided into categories with each category containing a number of individual operations. For the main flowsheet, the available operations are categorized in the following table. Operation Category Types All • All Unit Operations Vessels • 3-Phase Separator • Continuous Stirred Tank Reactor • Conversion Reactor • Equilibrium Reactor • Gibbs Reactor • Reboiler • Separator • Tank Heat Transfer Equipment • Air Cooler • Cooler • Fired Heater • Heat Exchanger • Heater • LNG Rotating Equipment • Compressor • Expander • Pump For detailed information on installing unit operations, refer to: • Section 8.1 - Installing Objects • Section 7.23.2 - Installing Streams or Operations in the HYSYS User Guide.1-6 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Operations Overview 1-7 ww ThPiping Equipment • Aspen Hydraulics Sub-Flowsheet • Compressible Gas Pipe • Liquid-liquid Hydrocyclone • Mixer • Pipe Segment • PIPESIM • PIPESIM Enhanced Link • Aspen HYSYS Pipeline Hydraulics Extension • Relief Valve • Tee • Valve Solids Handling • Baghouse Filter • Cyclone • Hydrocyclone • Rotary Vacuum Filter • Simple Solid Separator Reactors • Continuous-Stirred Tank Reactor (CSTR) • Conversion Reactor • Equilibrium Reactor • Gibbs Reactor • Plug Flow Reactor (PFR) • SULSIM Extension Prebuilt Columns • 3 Stripper Crude • 4 Stripper Crude • Absorber • Distillation • FCCU Main Fractionator • Liquid-Liquid Extractor • Reboiled Absorber • Refluxed Absorber • Three Phase Distillation • Vacuum Resid Tower Short Cut Columns • Component Splitter • Shortcut Column Sub-Flowsheets • 3 Stripper Crude • 4 Stripper Crude • Absorber • Aspen Hydraulics Sub-Flowsheet • Column Sub-Flowsheet • Distillation • FCCU Main Fractionator • Liquid-Liquid Extractor • Reboiled Absorber • Refluxed Absorber • Standard Sub-Flowsheet • Three Phase Distillation • Vacuum Resid Tower Operation Category Types1-7 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 1-8 Operations ww ThLogicals • Adjust • Balance • Black Oil Translator • Boolean And • Boolean CountDown • Boolean CountUp • Boolean Latch • Boolean Not • Boolean OffDly • Boolean OnDly • Boolean Or • Boolean XOr • Cause And Effect Matrix • Digital Control Point • DMCplus Controller • External Data Linker • MPC Controller • Parametric Unit Operation • PID Controller • Ratio Controller • Recycle • Selector Block • Set • Split Range Controller • Spreadsheet • Stream Cutter • Surge Controller • Transfer Function Block Extensions • User Defined User Ops • User Defined Electrolyte Equipment • Neutralizer • Precipitation • Crystalizer RefSYS Ops • Fluidized Catalytic Cracking • Manipulator • Petroleum Distillation • Petroleum Feeder • Petroleum Yield Shift Reactor • Product Blender Upstream Ops • Delumper • Lumper • PIPESIM The electrolyte operations are only available if your case is an electrolyte system (the selected fluid package must support electrolyte). Operation Category Types For information on the RefSYS operations refer to the RefSYS Option Guide. For information on the Upstream operations refer to the Upstream Option Guide.1-8 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Operations Overview 1-9 ww ThPrior to describing each of the unit operations, a quick overview of the material and energy streams is provided, as they are the means of transferring process information between operations. 1.2.2 Unit Operation Property View Although each unit operation differs in functionality and operation, in general, the unit operation property view remains fairly consistent in its overall appearance. The figure below shows a generic property view for a unit operation. Most operation property view contains the following three common objects: • Delete button. This button enables you to delete the unit operation from the current simulation case. Only the unit operation is deleted, any streams attached to the unit operation is left in the simulation case. • Status bar. This bar displays messages associated to the calculation status of the unit operation. The messages also indicate the missing or incorrect data in the operation. • Ignore checkbox. This checkbox enables you to toggle between including or excluding the unit operation in the simulation process calculation. Figure 1.1 The Name of the unit operation.The various pages of the active tab. The active tab of the property view.1-9 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 1-10 Operations ww ThTo ignore the operation during calculations, select the checkbox. HYSYS completely disregards the operation until you restore the operation to an active state by clearing the checkbox. The Operation property view also contain several different tabs which are operation specific, however the Design, Ratings, Worksheet, and Dynamics tabs can usually be found in each unit operation property view and have similar functionality. Tab Description Design Connects the feed and outlet streams to the unit operation. Other parameters such as pressure drop, heat flow, and solving method are also specified on the various pages of this tab. Ratings Rates and Sizes the unit operation vessel. Specification of the tab is not always necessary in Steady State mode, however it can be used to calculate vessel hold up. Worksheet Displays the Conditions, Properties, Composition, and Pressure Flow values of the streams entering and exiting the unit operation. Dynamics Sets the dynamic parameters associated with the unit operation such as valve sizing and pressure flow relations. Not relevant to steady state modelling. For information on dynamic modelling implications of this tab, refer to the HYSYS Dynamic Modeling guide. If negative pressure drop occurs in a vessel, the operation will not solve and a warning message appears in the status bar. Refer to Section 1.3.10 - Worksheet Tab for more information.1-10 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Operations Overview 1-11 ww ThObject Inspect Menu To access the Object Inspect menu of a unit operation property view, right-click on any empty area of the property view. The unit operation property view all have the following common commands in the Object Inspect menu: Figure 1.2 Command Description Print Datasheet Enables you to access the Select DataBlocks to Print property view. Open Page Enables you to open the active page into a new property view. Find in PFD Enables you to locate and display the object icon in the PFD property view. This command is useful if you already have access to an object's property view and want to see where the object is located in the PFD. This command is only available in the Object Inspect menu of the HYSYS stream & operation property views. Connections Enables you to access the Logical Connections For... Property View. Refer to Section 9.2.2 - Printing Datasheets from the HYSYS User Guide for more information.1-11 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 1-12 Operations ww ThLogical Connections For... Property View The Logical Connections for... property view enables you to determine simulation dependencies between objects which are not otherwise shown via connecting lines on the PFD. Certain HYSYS operations can write to any other object and if the user is looking at the object being written to, they have no way of telling this, other than that the value might be changing. For example, one can determine if one spreadsheet is writing to another. The table in the Logical Connections for... property view contains the following columns: • Remote Name column displays the name of the operation or stream being written to or read from the active object. Double-click on a particular entry of the Remote Name column to open the property view of the operation or stream. • Remote Type column displays the operation type (pump, valve, stream, and so forth) of the remote object from the current/active property view. The Logical Connections for... property view is different if accessed from a Spreadsheet property view since there is an additional column (This Name) in the table. The This Name column displays the spreadsheet cell that contains the information/variable connected to the spreadsheet. Figure 1.31-12 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Operations Overview 1-13 ww ThThe Show All checkbox enables you toggle between displaying or hiding all the other operations and streams that the selected object knows about. Duplicate connectivity information may be shown otherwise (either via a line on the PFD or some place else in a Logical operations property view, for example). Usually, you do not need to select this checkbox. To access the Logical Connections for… view of a HYSYS PFD object: 1. Open the object's property view. 2. Right-click in an empty area of the object's property view. The Object Inspect menu associated to the object appears. 3. Select Connections command from the Object Inspect menu. There is only one Show All checkbox for your HYSYS session. When the checkbox is changed, the current setting is effective for all Logical Connections For... property view. The information displayed in the Logical Connections for... property view is primarily use for the Spreadsheet, Cause and Effect Matrix operation, Event Scheduler operation, and any other operations that read/write from/to these property views. 1-13 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 1-14 Common Property Views ww Th1.3 Common Property Views Each operation in HYSYS contains some common information and options. These information and options are grouped into common property views, tabs, and pages. The following sections describe the common objects in HYSYS operation property view. 1.3.1 Graph Control Property View The Graph Control property view and its options are available for all plots in HYSYS. The options are grouped into five tabs: • Data. Contains options that enable you to modify the variable characteristics (type, name, colour, symbol, line style, and line thickness) of the plot. • Axes. Contains options that enable you to modify the axes characteristics (label name, display format, and axes value range) of the plot. • Title. Contains options that enable you to modify the title characteristics (label, font style, font colour, borders, and background colour) of the plot. Figure 1.4 Refer to Section 10.4 - Graph Control in the HYSYS User Guide for more information.1-14 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Operations Overview 1-15 ww Th• Legend. Contains options that enable you to modify the legend characteristics (border, background colour, font style, font colour, and alignment) of the plot. • Plot Area. Contains options that enable you to modify the plot characteristics (background colour, grid colour, frame colour, and cross hair colour) of the plot. To access the Graph Control property view, do one of the following: • Right-click any spot on an active plot and select the Graph Control command from the Object Inspect menu. • Click in the plot area to make the plot the active object. Then, either double-click on the plot Title or Legend to access the respective tab of the Graph Control property view. 1.3.2 Heat Exchanger Page The Heat Exchanger page in the Dynamics tab for most vessel unit operations in HYSYS contains the options use to configure heat transfer method within the unit operation. There are three options to choose from: • None radio button option indicates that there is no energy stream or heat exchanger in the vessel. The Heat Exchanger page is blank and you do not have to specify an energy stream for the unit operation to solve. Figure 1.51-15 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 1-16 Common Property Views ww Th• Duty radio button option indicates that there is an energy stream in the vessel. The Heat Exchanger page contains the HYSYS standard heater or cooler parameters and you have to specify an energy stream for the unit operation to solve. • Tube Bundle radio button option indicates that there is heat exchanger in the vessel and enables you to simulate a kettle reboiler or chiller. The Heat Exchanger page contains the parameters used to configure a heat exchanger and you have to specify material streams of the heat exchanger for the unit operation to solve. Duty Radio Button When you select the Duty radio button the following options are available. Heater Type Group In the Heater Type group, there are two heating methods available to the general vessel operation: • Vessel Heater • Liquid Heater The Tube Bundle option is only available in Dynamics mode. The Tube Bundle option is only available for the following unit operations: Separator, Three Phase Separator, Condenser, and Reboiler. Figure 1.61-16 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Operations Overview 1-17 ww ThIf you select the Vessel Heater radio button, 100% of the duty specified or calculated in the SP field is applied to the vessel’s holdup. where: Q = total heat applied to the holdup QTotal = duty calculated from the duty source If you select the Liquid Heater radio button, the duty applied to the vessel depends on the liquid level in the tank. You must specify the heater height in the Top of Heater and Bottom of Heater cells that appear with Heater Height as % Vessel Volume group. The heater height is expressed as a percentage of the liquid level in the vessel operation. The default values are 5% for the Top of the Heater and 0% for the Bottom of the Heater. These values are used to scale the amount of duty that is applied to the vessel contents. where: L = liquid percent level (%) T = top of heater (%) B = bottom of heater (%) The Percent Heat Applied can be calculated as follows: Q = QTotal (1.1) (1.2) (1.3) Q 0 L B<( ) Q L B– T B– ------------QTotal B L T≤ ≤( ) Q QTotal L T>( ) = = = Percent Heat Applied Q QTotal --------------- 100%×=1-17 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 1-18 Common Property Views ww ThIt is shown that the percent of heat applied to the vessel’s holdup directly varies with the surface area of liquid contacting the heater. Duty Source/Source Group In the Duty Source/Source group, you can choose whether HYSYS calculates the duty applied to the vessel from a direct energy source or from a utility source. • If you select the Direct Q radio button, the Direct Q group appears, and you can directly specify the duty applied to the holdup in the SP field. Figure 1.7 Figure 1.8 0 20 40 60 80 100 0 20 40 60 80 100 Liquid Percent Level, L Pe rc en t o f H ea t A p p lie d Percent Heat Applied for a Liquid Heater B T1-18 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Operations Overview 1-19 ww ThThe following table describes the purpose of each object in the Direct Q group. • If you select the Utility radio button, the Utility Properties group appears, and you can specify the flow of the utility fluid. The duty is then calculated using the local overall heat transfer coefficient, the inlet fluid conditions, and the process conditions. The calculated duty is then displayed in the SP field or the Heat Flow field. If you select the Heating radio button, the duty shown in the SP field or Heat Flow field is added to the holdup. If you select the Cooling radio button, the duty shown in the SP field or Heat Flow field is subtracted from the holdup. Object Description SP The heat flow value in this cell is the same value specified in the Duty field of the Parameters page on the Design tab. Any changes made in this cell is reflected on the Duty field of the Parameters page on the Design tab. Min. Available Allows you to specify the minimum amount of heat flow. Max. Available Allows you to specify the maximum amount of heat flow. Figure 1.9 For more information regarding how the utility option calculates duty, refer to Chapter 5 - Logical Operations.1-19 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 1-20 Common Property Views ww ThTube Bundle Radio Button When you select the Tube Bundle radio button, the following options are available. The Tube Bundle option allows you to configure a shell tube heat exchanger (for example, kettle reboiler or kettle chiller). • In the kettle reboiler, the process fluid is typically on the shell side and the process fluid is fed into a liquid "pool" which is heated by a number of tubes. A weir limits the amount of liquid in the pool. The liquid overflow is placed under level control and provides the main liquid product. The vapor is circulated back to the vessel. • In the kettle chiller, the process fluid is typically on the tube side with a refrigerant on the shell side. The refrigerant if typically pure and cools by evaporation. The setup is similar to the reboiler except that there is no weir or level control. Figure 1.10 The Tube Bundle option is only available in Dynamics mode. If you had an energy stream attached to the unit operation, HYSYS automatically disconnects the energy stream when you switch to the Tube Bundle option.1-20 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Operations Overview 1-21 ww ThThe unit operation icon in the PFD also changes to indicate that a heat exchanger has been attached to the unit operation. The following table lists and describes the options available to configure the heat exchanger: Figure 1.11 Object Description Parameters group Tube Volume cell Allows you to specify the volume of the tubes in the heat exchanger. Vessel Liquid U cell Allows you to specify the heat transfer rate of the liquid in the shell. Vessel Vapor U cell Allows you to specify the heat transfer rate of the vapour in the shell. Tube Liquid U cell Allows you to specify the heat transfer rate of the liquid in the tube. Tube Vapor U cell Allows you to specify the heat transfer rate of the vapour in the tube. Heat Transfer Area cell Allows you to specify the total heat transfer area between the fluid in the shell and the fluid in the tube. Bundle Top Height cell Allows you to specify the location of the top tube/ bundle based on the height from the bottom of the shell. Bundle Bottom Height cell Allows you to specify the location of the bottom tube/ bundle based on the height from the bottom of the shell. Specs group Tube Dp cell Allows you to specify the pressure drop within the tubes. You have to select the associate checkbox in order to specify the pressure drop. Tube K cell Allows you to specify the pressure flow relationship value within the tubes. You have to select the associate checkbox in order to specify the pressure flow relationship value.1-21 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 1-22 Common Property Views ww ThTube UA Reference Flow cell Allows you to set a reference point that uses HYSYS to calculate a more realistic UA value. If no reference point is set then UA is fixed. UA is the product of overall heat transfer multiply with overall heat transfer area, and depends on the flow rate. If a value is specified for the Reference Flow, the heat transfer coefficient is proportional to the . The equation below is used to determine the actual UA: Reference flows generally help to stabilize the system when you do shut downs and startups as well. Minimum Flow Scale Factor cell The ratio of mass flow at time t to reference mass flow is also known as flow scaled factor. The minimum flow scaled factor is the lowest value which the ratio is anticipated at low flow regions. This value can be expressed in a positive value or negative value. • A positive value ensures that some heat transfer still takes place at very low flows. • A negative value ignores heat transfer at very low flows. A negative minimum flow scale factor is often used in shut downs if you are not interested in the results or run into problems shutting down the heat exchanger. If the Minimum Flow Scale Factor is specified, the actual UA is calculated using the ratio if the ratio is greater than the Min Flow Scale Factor. Otherwise the Min Flow Scale Factor is used. Calculate K button Allows you to calculate the K value based on the heat exchanger specifications. Shell Dp cell Allows you to specify the pressure drop within the shell. Summary group Actual UA cell Displays the calculated UA in Dynamics mode. Shell Liq. Percent Level cell Displays the calculated liquid level in the shell at percentage value. Tube Liq. Volume Percent cell Allows you to specify in percentage value the volume of liquid in the tube. Shell Duty cell Displays the calculated duty value in the shell. Use Tube Trivial Level and Fraction Calc. radio button Allows you to select the volume percent level variable for the vessel fraction calculation. This option uses a variable that is independent of the vessel shape or orientation. Object Description mass flow ratio( )0.8 UAactual UAspecified mass flowcurrent mass flowreference -----------------------------------------⎝ ⎠ ⎛ ⎞ 0.8 ×= mass flowcurrent mass flowreference -----------------------------------------⎝ ⎠ ⎛ ⎞ 0.81-22 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Operations Overview 1-23 ww Th1.3.3 Holdup Page Each unit operation in HYSYS has the capacity to store material and energy. The Holdup page contains information regarding the properties, composition, and amount of the holdup. Most Holdup page contains the following common objects/ options: Use Tube Normal Level and Fraction Calc. radio button Allows you to select the liquid percent level variable for the vessel fraction calculation. This option uses a variable that is dependant of the vessel shape and orientation. ViewTubeHoldUp button Allows you to access the tube HoldUp Property View. Figure 1.12 Objects Description Phase column Displays the phase of the fluid available in the unit operation’s holdup volume. Each available phase occupies a volume space within the unit operation. Accumulation column Displays the rate of change of material in the holdup for each phase. Moles column Displays the amount of material in the holdup for each phase. Volume column Displays the holdup volume of each phase. Object Description1-23 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 1-24 Common Property Views ww Th1.3.4 HoldUp Property View The HoldUp property view displays the detailed calculated results of the holdup data in the following tabs: • General. Displays the phase, accumulation, moles, volume, duty and holdup pressure of the heat exchanger. Select the Active Phase Flip Check checkbox to enable HYSYS to check if there is a phase flip between Liquid 1 (light liquid) and Liquid 2 (heavy liquid) during simulation and generate a warning message whenever the phase flip occur. If the checkbox is clear, HYSYS generates a warning only on the first time the phase flip occur. Total row Displays the sum of the holdup accumulation rate, mole value, and volume value. Advanced button Enables you to access the unit operation’s HoldUp Property View that provides more detailed information about the holdup of that unit operation. Figure 1.13 Objects Description Refer to Section 1.3.7 - Advanced Holdup Properties in the HYSYS Dynamic Modeling guide for more information.1-24 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Operations Overview 1-25 ww Th• Nozzles. Allows you to modify nozzle configuration attached to the heat exchanger. • Efficiencies. Allows you to modify the efficiency of the recycle, feed nozzle, and product nozzle of the heat exchanger. Figure 1.14 Figure 1.151-25 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 1-26 Common Property Views ww Th• Properties. Displays the temperature, pressure, enthalpy, density, and molecular weight of the holdup in the heat exchanger. • Compositions. Displays the composition of the holdup in the heat exchanger. Figure 1.16 Figure 1.171-26 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Operations Overview 1-27 ww Th1.3.5 Notes Page/Tab The Notes page/tab provides a text editor where you can record any comments or information regarding the specific unit operation or the simulation case in general. To add a comment or information in the Notes page/tab: 1. Go to the Notes page/tab. 2. Use the options in the text editor toolbar to manipulate the appearance of the notes. The following table lists and describes the options available in the text editor toolbar. Figure 1.18 Object Icon Description Font Type Use the drop-down list to select the text type for the note. Font Size Use the drop-down list to select the text size for the note. Font Colour Click this icon to select the text colour for the note. Bold Click this icon to bold the text for the note. Italics Click this icon to italize the text for the note. Underline Click this icon to underline the text for the note. Align Left Click this icon to left justify the text for the note. Centre Click this icon to center justify the text for the note. Align Right Click this icon to right justify the text for the note.1-27 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 1-28 Common Property Views ww Th3. Click in the large text field and type your comments. The date and time when you last modified the information in the text field will appear below your comments. Notes Manager The Notes Manager lets you search for and manage notes for a case. To access the Notes Manager, select Notes Manager command from the Flowsheet menu, or press the CTRL G hot key. Bullets Click this icon to apply bullets to the text for the note. Insert Object Click this icon to insert an object (for example an image) in the note. The information you enter in the Notes tab or page of any operations can also be viewed from the Notes Manager property view. Figure 1.19 Object Icon Description Click the Plus icon to expand the tree browser.1-28 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Operations Overview 1-29 ww ThView/Add/Edit Notes To view, add, or edit notes for an object, select the object in the List of Objects group. Existing object notes appear in the Note group. • To add a note, type the text in the Note group. A time and date stamp appears automatically. • To format note text, use the text tools in the Note group toolbar. You can also insert graphics and other objects. • Click the Clear button to delete the entire note for the selected object. • Click the View button to open the property view for the selected object. Search Notes The Notes Manager allows you to search notes in three ways: • Select the View Objects with Notes Only checkbox (in the List of Objects group) to filter the list to show only objects that have notes. • Select the Search notes containing the string checkbox, then type a search string. Only objects with notes containing that string appear in the object list. You can change the search option to be case sensitive by selecting the Search is Case Sensitive checkbox. The case sensitive search option is only available if you are searching by string. • Select the Search notes modified since checkbox, then type a date. Only objects with notes modified after this date will appear in the object list. 1.3.6 Nozzles Page The Nozzles page (from the Rating Tab) in most of the operations property view enables you to specify the elevation and diameter of the nozzles connected to the operation. The Nozzles page is only available if the HYSYS Dynamics license is activated.1-29 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 1-30 Common Property Views ww ThDepending on the type of operation, the options in the Nozzles page varies. The following table lists and describes the common options available in the page: 1.3.7 Stripchart Page/Tab The Stripchart page or tab allows you to select and create a strip chart based on a default set of variable. Figure 1.20 Object Description Base Elevation Relative to Ground Level field Enables you to specify the height/elevation between the bottom of the operation and the ground. Diameter row Enables you to specify the diameter of the nozzle for each material stream flowing into and out of the operation. Elevation (Base) row Enables you to specify the height/elevation between the nozzle and the base of the operation. Elevation (Ground) row Enables you to specify the height/elevation between the nozzle and the ground. Figure 1.21 Refer to Section 1.6.2 - Nozzles in the HYSYS Dynamic Modeling guide for more information. Refer to Section 11.7.3 - Strip Charts in the HYSYS User Guide for more information about strip charts.1-30 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Operations Overview 1-31 ww ThDepending on the object property view, the strip chart sets will contain variables appropriate for the object. For example, the strip chart set ToolTip Properties for a mixer will contain the following variables: Product Temperature, Product Pressure, and Product Molar Flow. The strip chart set ToolTip Properties for a separator will contain the following variables: Vessel Temperature, Vessel Pressure, and Liquid Volume Percent. To select the strip chart set: 1. Open the object’s property view, and access the Stripchart page or tab. 2. Select the strip chart set you want using the Variable Set drop-down list. 3. Clicking the Create Stripchart button. The new strip chart property view appears. If you closed the strip chart property view, you can open the strip chart property view again using the options in the Databook property view. Figure 1.22 Figure 1.23 The new strip chart is automatically named: objectname-DLn where: objectname = name of the object n = an integer number that increases each time a new strip chart with the same objectname is created Refer to Section 11.7 - Databook in the HYSYS User Guide for more information.1-31 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 1-32 Common Property Views ww Th1.3.8 User Variables Page/Tab The User Variables page or tab enables you to create and implement variables in the HYSYS simulation case. The following table outlines options in the user variables toolbar: Figure 1.24 Object Icon Function Current Variable Filter drop-down list Enables you to filter the list of variables in the table based on the following types: • All • Real • Enumeration • Text • Code Only • Message Create a New User Variable icon Enables you to create a new user variable and access the Create a New User Variable property view. Edit the Selected User Variable icon Enables you to edit the configuration of an existing user variable in the table. You can also open the edit property view of a user variable by double-clicking on its name in the table. Delete the Selected User Variable icon Enables you to delete the select user variable in the table. HYSYS requires confirmation before proceeding with the deletion. If a password has been assigned to the User Variable, the password is requested before proceeding with the deletion. Sort Alphabetically icon Enables you to sort the user variable list in ascending alphabetical order. For more information on the user variables, refer to Chapter 5 - User Variables in the HYSYS Customization Guide.1-32 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Operations Overview 1-33 ww ThTo add a user variable: 1. Access the User Variables page or tab in the object property view. 2. Click the Create a New User Variable icon. The Create New User Variable property view appears. 3. In the Name field, type in the user variable name. Sort by Execution Order icon Enables you to sort the user variable list according to the order by which they are executed by HYSYS. Sorting by execution order is important if your user variables have order dependencies in their macro code. Normally, you should try and avoid these types of dependencies. Move Selected Variable Up In Execution Order icon Enables you to move the selected user variable up in execution order. Move Selected Variable Down In Execution Order icon Enables you to move the selected user variable down in the execution order. Show/Hide Variable Enabling Checkbox icon Enables you to toggle between displaying or hiding the Variable Enabling checkboxes associated with each user variable. By default, the checkboxes are not displayed. Object Icon Function Create a New User Variable icon1-33 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 1-34 Common Property Views ww Th4. Fill in the rest of the user variable parameters as indicated by the figure below. You can define your own filters on the Filters tab of the User Variable property view. Figure 1.25 Code field Allows you to add password security to the user variable. Select the data type, dimension, and unit type using these drop- down list. These tabs contain more options for configuring the user variable. 1-34 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Operations Overview 1-35 ww Th1.3.9 Variable Navigator Property View The Variable Navigator property view enables you to browse for and select variable, such as selecting a process variable for a controller or a strip chart. Figure 1.26 Object Description Flowsheet/ Case/Basis Object/Utility group Enables you to select the flowsheet/case/basis object/ utility containing the variable you want. This type of objects available in this group depends on the selection in the Navigator Scope group. Object group Enables you to select the object containing the variable you want. The list of available objects depend on the flowsheet you selected in the Flowsheet group. Variable group Enables you to select the variable you want. The list of available variables depend on the object you selected in the Object group. Variable Specifics group Enables you to select a specific item of the variable. The list of available items depend on the variable you selected in the Variable group. More Specific group Enables you to select in detail the item of the variable you want. The list of available sub-items depend on the item you selected in the Variable Specifics group. Navigator Scope group Enables you to select the area/location containing the variable you want. Refer to Section 11.21 - Variable Navigator in the HYSYS User Guide for more information.1-35 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 1-36 Common Property Views ww Th1.3.10 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the unit operation. • The Conditions and Composition pages contain selected information from the corresponding pages of the Worksheet tab for the stream property view. • The Properties page displays the property correlations of the inlet and outlet streams of the unit operations. The following is a list of the property correlations: Variable Description field Enables you to provide a name for the selected variable. OK button Enables you to confirm the selection of the variable and close the navigator property view. This button is only available when you have selected the variable in the groups. Add button Enables you to confirm the selection of the variable and keep the navigator property view open to select more variable. This button is only available when the operation allows multiple variable selection. Object Filter group Enables you to filter the types of objects displayed in the Object group. Disconnect button Enables you to remove/disconnect the selected variable and close the property view. This button is only available when a variable is selected in the navigator property view. Close button Enables you to close the navigator property view. This button is only available if you have selected multiple variable in the same navigator property view. Cancel button Enables you to close the navigator property view without making any changes or variable selection. • Vapour / Phase Fraction • Vap. Frac. (molar basis) • Temperature • Vap. Frac. (mass basis) • Pressure • Vap. Frac. (volume basis) • Actual Vol. Flow • Molar Volume • Mass Enthalpy • Act. Gas Flow • Mass Entropy • Act. Liq. Flow • Molecular Weight • Std. Liq. Flow • Molar Density • Std. Gas Flow Object Description1-36 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Operations Overview 1-37 ww Th• The PF Specs page contains a summary of the stream property view Dynamics tab. • Mass Density • Watson K • Std. Ideal Liquid Mass Density • Kinematic Viscosity • Liquid Mass Density • Cp/Cv • Molar Heat Capacity • Lower Heating Value • Mass Heat Capacity • Mass Lower Heating Value • Thermal Conductivity • Liquid Fraction • Viscosity • Partial Pressure of CO2 • Surface Tension • Avg. Liq. Density • Specific Heat • Heat of Vap. • Z Factor • Mass Heat of Vap. The Heat of Vapourisation for a stream in HYSYS is defined as the heat required to go from saturated liquid to saturated vapour. The PF Specs page is relevant to dynamics cases only.1-37 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 1-38 Common Property Views ww Th1-38 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -1 ww ThColumn Operationsw.cadfamily.com EMa e document is for study -1 il:cadserv21@hotmail.com only,if tort to your rights,please inform us,we will delete -2 Column Operations www.cadfamily.com EMa The document is for study -2 il:cadserv21@hotmail.com only,if tort to your rights,please inform us,we will delete -3 Column Operations www.cadfamily.com EMa The document is for study -3 il:cadserv21@hotmail.com only,if tort to your rights,please inform us,we will delete -4 Column Subflowsheet ww ThColumn Subflowsheet The Column is a special type of subflowsheet in HYSYS. A subflowsheet contains equipment and streams, and exchanges information with the parent flowsheet through the connected internal and external streams. From the main simulation environment, the Column appears as a single, multi-feed multi- product operation. In many cases, you can treat the column in exactly that manner. You can also work inside the Column subflowsheet. You can do this to “focus” your attention on the Column. When you move into the Column build environment, the main simulation is “cached.” All aspects of the main environment are paused until you exit the Column build environment. When you return to the Main Environment, the Desktop re-appears as it was when you left it. You can also enter the Column build environment when you want to create a custom column configuration. Side equipment such as pump arounds, side strippers, and side rectifiers can be added from the Column property view in the main simulation. However, if you want to install multiple tray sections or multiple columns, you need to enter the Column build environment. Once inside, you can access the Column-specific operations (Tray Sections, Heaters/Coolers, Condensers, Reboilers, and sof forth) and build the column as you would any other flowsheet. If you want to create a custom column template for use in other simulations, on the File menu select the New command, and then select the Column sub-command. Since this is a column template, you can access the Column build environment directly from the Basis environment. Once you have created the template, you can store it on disk. Before you install the template in another simulation, ensure that the Use Input Experts checkbox in the Session Preferences property view is cleared. For detailed information about subflowsheet manipulation, refer to Chapter 3 - Flowsheet in the HYSYS User Guide.-4 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -5 ww ThHaving a Column subflowsheet provides a number of advantages: • isolation of the Column Solver. • optional use of different Property Packages. • construction of custom templates. • ability to solve multiple towers simultaneously. Isolation of the Column Solver One advantage of the Column build environment is that it allows you to make changes, and focus on the Column without requiring a recalculation of the entire flowsheet. When you enter the Column build environment, HYSYS clears the Desktop by caching all property views that were open in the parent flowsheet. Then the property views that were open when you were last in the Column build environment are re-opened. Once inside the Column build environment, you can access profiles, stage summaries, and other data, as well as make changes to Column specifications, parameters, equipment, efficiencies, or reactions. When you have made the necessary changes, simply run the Column to produce a new converged solution. The parent flowsheet cannot recalculate until you return to the parent build environment. The subflowsheet environment permits easy access to all streams and operations associated with your column. • Click the PFD icon to view the column subflowsheet. • If you want to access information regarding column product streams, click the Workbook icon to view the Column workbook, which displays the Column information exclusively. While in the Column subflowsheet, you can view the Workbook or PFD for both the Parent flowsheet or subflowsheet by using the Workbooks option or PFDs option in the Tools menu. In this chapter, the use of the Column property view and Column Templates are explained. Section - Column-Specific Operations, describes the unit operations available in the Column build environment. PFD icon Workbook icon-5 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -6 Column Subflowsheet ww ThIndependent Fluid Package HYSYS allows you to specify a unique fluid package for the Column subflowsheet. Here are some instances where a separate fluid package is useful: • If a column does not use all of the components used in the main flowsheet, it is often advantageous to define a new fluid package with only the components that are necessary. This speeds up the column solution. • In some cases, a different fluid package can be better suited to the column conditions. For example, if you want to redefine Interaction Parameters such that they are applicable for the operating range of the column. • In Dynamic mode, different columns can operate at very different temperatures and pressures. With each fluid package, you can define a different dynamic model whose parameters can be regressed in the appropriate temperature and pressure range, thus, improving the accuracy and stability of the dynamic simulation. Ability to construct Custom Column Configurations Custom column configurations can be stored as templates, and recalled into another simulation. To create a custom template, on the File menu select the New command, and then select the Column sub-command. When you store the template, it has a *.col extension. There exists a great deal of freedom when defining column configurations, and you can define column setups with varying degrees of complexity. You can use a wide array of column operations in a manner which is straightforward and flexible. Complex custom columns and multiple columns can be simulated within a single subflowsheet using various combinations of subflowsheet equipment.-6 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -7 ww ThColumn arrangements are created in the same way that you build the main flowsheet: • accessing various operations. • making the appropriate connections. • defining the parameters. Use of Simultaneous Solution Algorithm The Column subflowsheet uses a simultaneous solver whereby all operations within the subflowsheet are solved simultaneously. The simultaneous solver permits you to install multiple unit operations within the subflowsheet (interconnected columns, for example) without the need for Recycle blocks. Dynamic Mode There are several major differences between the dynamic column operation and the steady state column operation. One of the main differences is the way in which the Column subflowsheet solves. In steady state if you are in the Column subflowsheet, calculations in the main flowsheet are put on Hold until the focus is returned to the main flowsheet. When running in dynamics, calculations in the main flowsheet proceed at the same time as those in the Column subflowsheet. Another difference between the steady state column and the dynamic column is with the column specifications. Steady state column specifications are ignored in dynamics. To achieve the column specifications when using dynamics, control schemes must be added to the column. Finally, although it is possible to turn off static head contributions for the rest of the simulation, this option does not apply to the column. When running a column in Dynamic mode, the static head contributions are always used in the column calculations.-7 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -8 Column Subflowsheet ww ThColumn Property View The Column property view (the representation of the Column within the main or parent flowsheet) essentially provides you with complete access to the Column. From the Column property view, you can change feed and product connections, specifications, parameters, pressures, estimates, efficiencies, reactions, side operations, and view the Profiles, Work Sheet, and Summary. You can also run the column from the main flowsheet just as you would from the Column subflowsheet. If you want to make a minor change to a column operation (for instance, resize a condenser) you can call up that operation using the Object Navigator without entering the Column subflowsheet. Major changes, such as adding a second tray section, require you to enter the Column subflowsheet. Figure 2.1 Side equipment (for example, pump arounds and side strippers) is added from the Column property view. For more information, refer to Section - Column Property View.-8 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -9 ww ThTo access to the Column build environment, click the Column Environment button at the bottom of the Column property view. Main Flowsheet and Column Subflowsheet Relationship Unlike other unit operations, the Column contains its own subflowsheet, which in turn, is contained in the Parent (usually the main) flowsheet. When you are working in the parent flowsheet, the Column appears just as any other unit operation, with multiple input and output streams, and various adjustable parameters. When you install a Column, HYSYS creates a subflowsheet containing all operations and streams associated with the template you have chosen. This subflowsheet operates as a unit operation in the main flowsheet. Figure 2.2 shows this concept of a Column subflowsheet within a main flowsheet. Main Flowsheet / Subflowsheet Concept Consider a simple absorber in which you want to remove CO2 from a gas stream using H2O as the solvent. A typical approach to setting up the problem would be as follows: 1. Create the gas feed stream, FeedGas, and the water solvent stream, WaterIn, in the main flowsheet. 2. Click the Absorber icon from the Object Palette. Enter the Column subflowsheet to add new pieces of equipment, such as additional Tray Sections or Reboilers. If you make a change to the Column while you are working in the parent, or main build environment, both the Column and the parent flowsheets are automatically recalculated. Absorber icon-9 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -10 Column Subflowsheet ww Th3. Specify the stream names, number of trays, pressures, estimates, and specifications. You must also specify the names of the outlet streams, CleanGas and WaterOut. 4. Run the Column from the main flowsheet Column property view. When you connected the streams to the tower, HYSYS created internal streams with the same names. The Connection Points or “Labels” serve to connect the main flowsheet streams to the subflowsheet streams and facilitate the information transfer between the two flowsheets. For instance, the main flowsheet stream WaterIn is connected to the subflowsheet stream WaterIn. A subflowsheet stream that is connected to a stream in the main flowsheet is automatically given the same name with “@subflowsheet tag” attached at the end of the name. An example is the stream named “WaterIn” has the subflowsheet stream named “WaterIn@Col1”. Figure 2.2-10 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -11 ww ThWhen working in the main build environment, you “see” the Column just as any other unit operation, with a property view containing parameters such as the number of stages, and top and bottom pressures. If you change one of these parameters, the subflowsheet recalculates (just as if you had clicked the Run button); the main flowsheet also recalculates once a new column solution is reached. However, if you are inside the Column subflowsheet build environment, you are working in an entirely different flowsheet. To make a major change to the Column such as adding a reboiler, you must enter the Column subflowsheet build environment. When you enter this environment, the main flowsheet is put on “hold” until you return. Column Theory Multi-stage fractionation towers, such as crude and vacuum distillation units, reboiled demethanizers, and extractive distillation columns, are the most complex unit operations that HYSYS simulates. Depending on the system being simulated, each of these towers consists of a series of equilibrium or non- equilibrium flash stages. The vapour leaving each stage flows to the stage above and the liquid from the stage flows to the stage below. A stage can have one or more feed streams flowing onto it, liquid or vapour products withdrawn from it, and can be heated or cooled with a side exchanger. The connected streams do not necessarily have the same values. All specified values are identical, but calculated stream variables can be different depending on the fluid packages and transfer basis (defined on the Flowsheet tab). If you delete any streams connected to the column in the main flowsheet, these streams are also deleted in the Column subflowsheet. For information regarding the electrolyte column theory, refer to Section 1.6.8 - Aspen HYSYS Column Operation in the HYSYS OLI Interface Reference Guide.-11 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -12 Column Theory ww ThThe following figure shows a typical stage j in a Column using the top-down stage numbering scheme. The stage above is j-1, while the stage below is j+1. The stream nomenclature is shown in the figure below. More complex towers can have pump arounds, which withdraw liquid from one stage of the tower and typically return it to a stage farther up the column. Small auxiliary towers, called sidestrippers, can be used on some towers to help purify side liquid products. With the exception of Crude distillation towers, very few columns have all of these items, but virtually any type of column can be simulated with the appropriate combination of features. It is important to note that the Column operation by itself is capable of handling all the different fractionation applications. HYSYS has the capability to run cryogenic towers, high pressure TEG absorption systems, sour water strippers, lean oil absorbers, complex crude towers, highly non-ideal azeotropic distillation columns, and so forth. There are no programmed limits for the number of components and stages. The size of the column which you can solve depends on your hardware configuration and the amount of computer memory you have available. The column is unique among the unit operations in the methods used for calculations. There are several additional underlying equations which are used in the column. Figure 2.3 Fj Lj-1 Vj VSDj Qj Vj+1 Lj LSDj Stage j Rj F = Stage feed stream L = Liquid stream travelling to stage below V = Vapor stream travelling to stage above LSD = Liquid side draw from stage VSD = Vapor side draw from stage Q = Energy stream entering stage-12 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -13 ww ThThe Francis Weir equation is the starting point for calculating the liquid flowrate leaving a tray: where: LN = liquid flowrate leaving tray N C = units conversion constant = density of liquid on tray lw = weir length h = height of liquid above weir The vapour flowrate leaving a tray is determined by the resistance equation: where: Fvap = vapour flowrate leaving tray N k = conductance, which is a constant representing the reciprocal of resistance to flow = dry hole pressure drop (2.1) (2.2) For columns the conductance, k, is proportional to the square of the column diameter. The pressure drop across a stage is determined by summing the static head and the frictional losses. LN Cρlwh1.5= ρ Fvap k PfrictionΔ= PfrictionΔ-13 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -14 Column Theory ww ThIt is possible to use column stage efficiencies when running a column in dynamics. The efficiency is equivalent to bypassing a portion of the vapour around the liquid phase, as shown in the figure below, where n is the specified efficiency. HYSYS has the ability to model both weeping and flooding inside the column. If is very small, the stage exhibits weeping. Therefore it is possible to have a liquid flow to the stage below even if the liquid height over the weir is zero. For the flooding condition, the bulk liquid volume approaches the tray volume. This can be observed on the Holdup page in the Dynamics tab, of either the Column Runner or the Tray Section property view. Three Phase Theory For non-ideal systems with more than two components, boundaries can exist in the form of azeotropes, which a simple distillation system cannot cross. The formation of azeotropes in Figure 2.4 PfrictionΔ-14 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -15 ww Tha three phase system provides a thermodynamic barrier to separating chemical mixtures. Distillation schemes for non-ideal systems are often difficult to converge without very accurate initial guesses. To aid in the initialization of towers, a Three Phase Input Expert is available to initialize temperatures, flows, and compositions. Detection of Three Phases Whenever your Column converges, HYSYS automatically performs a Three Phase Flash on the top stage. If a second liquid phase is detected, and no associated water draw is found, a warning message appears. If there is a water draw, HYSYS checks the next stage for a second liquid phase, with the same results as above. This continues down the Tower until a stage is found that is two phase only. HYSYS always indicates the existence of the second liquid phase. This continues until the Column reverts to VLE operation, or all applicable stages have water draws placed on them. For non-ideal multicomponent systems, DISTIL is an excellent tool for determining process viability. This conceptual design software application also determines the optimal feed tray location and allows direct export of column specifications to HYSYS for use as an initial estimate. Contact your local AspenTech representative for details. Look at the Trace Window for column convergence messages. If there is a three phase stage below a stage that was found to be two phase, the three phase stage is not detected because the checking would have ended in the previous two phase stage. Refer to Section - Templates for further details on the three phase capabilities in HYSYS.-15 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -16 Column Theory ww ThInitial Estimates Initial estimates are optional values that you provide to help the HYSYS algorithm converge to a solution. The better your estimates, the quicker HYSYS converges. There are three ways for you to provide the column with initial estimates: • Provide the estimate values when you first build the column. • Go to the Profiles or Estimates page on the Parameters tab to provide the estimate values. • Go to the Monitor or Specs page on the Design tab to provide values for the default specifications or add your own specifications. It is important to remember, when the column starts to solve for the first time or after the column has been reset, the specification values are also initial estimates. So if you replaced one of the original default specifications (overhead vapour flow, side liquid draw or reflux ratio) with a new active specification, the new specification value is used as initial estimates. For this reason it is recommended you provide reasonable specification values initially even if you can replace them while the column is solving or after the column has solved. Temperatures Temperature estimates can be given for any stage in the column, including the condenser and reboiler, using the Profiles page in the Parameters tab of the Column property view. Intermediate temperatures are estimated by linear interpolation. When large temperature changes occur across the condenser or bottom reboiler, it would be helpful to provide an Although HYSYS does not require any estimates to converge to a solution, reasonable estimates help in the convergence process. Refer to Section - Templates for more information regarding default specifications.-16 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -17 ww Thestimate for the top and bottom trays in the tray section. Mixing Rules at Feed Stages When a feed stream is introduced onto a stage of the column, the following sequence is employed to establish the resulting internal product streams: 1. The entire component flow (liquid and vapour phase) of the feed stream is added to the component flows of the internal vapour and liquid phases entering the stage. 2. The total enthalpy (vapour and liquid phases) of the feed stream is added to the enthalpies of the internal vapour and liquid streams entering the stage. 3. HYSYS flashes the combined mixture based on the total enthalpy at the stage Pressure. The results of this process produce the conditions and composition of the vapour and liquid phases leaving the stage. In most physical situations, the vapour phase of a feed stream does not come in close contact with the liquid on its feed stage. However if this is the case, the column allows you to split all material inlet streams into their phase components before being fed to the column. The Split Inlets checkbox can be selected in the Setup page of the Flowsheet tab. You can also set all the feed streams to a column to always split, by selecting the appropriate checkbox in the Options page from the Simulation tab of the Session Preferences property view. Basic Column Parameters Regardless of the type of column, the Basic Column Parameters remain at their input values during convergence. If the overhead product is a subcooled liquid, it is best to specify an estimated bubble-point temperature for the condenser rather than the subcooled temperature.-17 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -18 Column Theory ww ThPressure The pressure profile in a Column Tray Section is calculated using your specifications. You can either explicitly enter all stage pressures or enter the top and bottom tray pressures (and any intermediate pressures) such that HYSYS can interpolate between the specified values to determine the pressure profile. Simple linear interpolation is used to calculate the pressures on stages which are not explicitly specified. You can enter the condenser and reboiler pressure drops explicitly within the appropriate operation property view. Default pressure drops for the condenser and reboiler are zero, and a non-zero value is not necessary to produce a converged solution. If the pressure of a Column product stream (including side vapour or liquid draws, side stripper bottom streams, or internal stream assignments) is set (either by specification or calculation) prior to running the Column, HYSYS “backs” this value into the column and uses this value for the convergence process. If you do specify a stream pressure that allows HYSYS to calculate the column pressure profile, it is not necessary to specify another value within the column property view. If you later change the pressure of an attached stream, the Column is rerun. Number of Stages The number of stages that you specify for the tray section does not include the condenser and bottom reboiler, if present. If sidestrippers are to be added to the column, their stages are not included in this number. By default, HYSYS numbers stages from the top down. If you want, you can change the numbering Recall that whenever a change is made in a stream, HYSYS checks all operations attached to that stream and recalculates as required.-18 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -19 ww Thscheme to bottom-up by selecting this scheme on the Connections page of the Design tab. HYSYS initially treats the stages as being ideal. If you want your stages to be treated as real stages, you must specify efficiencies on the Efficiencies page of the Parameters tab. Once you provide efficiencies for the stages, even if the value you specify is 1, HYSYS treats the stages as being real. Stream The feed stream and product stream location, conditions, and composition are treated as Basic Column Parameters during convergence. Pressure Flow In the following sections, the pressure flow specifications presented are the recommended configurations if no other equipment, such as side strippers, side draws, heat exchanger, and so forth, are connected. Other combinations of pressure flow specifications are possible, however they can lead to less stable configurations. Regardless of the pressure flow specification configuration, when performing detailed dynamic modeling it is recommended that at least valves be added to all boundary streams. Once valves have been added, the resulting boundary streams can all be specified with pressure specifications, and, where necessary, flow controlled with flow controllers. Absorber The basic Absorber column has two inlet and two exit streams. When used alone, the Absorber has four boundary streams and so requires four Pressure Flow specifications. A pressure specification is always required for the liquid product stream leaving the bottom of the column. A second pressure specification should be added to the vapour product of the -19 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -20 Column Theory ww Thcolumn, with the two feed streams having flow specifications. If there are down stream unit operations attached to the liquid product stream, then a column sump needs to be simulated. There are several methods for simulating the column sump. A simple solution is to use a reboiled absorber, with the reboiler duty stream specified as zero in place of the absorber. Another option is to feed the liquid product stream directly into a separator, and return the separator vapour product to the bottom stage of the column. Figure 2.5 The column shows the recommended pressure flow specifications for a stand alone absorber column.-20 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -21 ww ThRefluxed Absorber The basic Refluxed Absorber column has a single inlet and two or three exit streams, depending on the condenser configuration. When used alone, the Refluxed Absorber has three or four boundary streams (depending on the condenser) and requires four or five pressure-flow specifications; generally two pressure and three flow specifications. A pressure specification is always required for the liquid product stream leaving the bottom of the column. The extra specification is required due to the reflux stream and is discussed in Section - Column-Specific Operations. If there are down stream unit operations attached to the liquid product stream, then a column sump needs to be simulated. There are several methods for simulating the column sump. A simple solution is to use a distillation column, with the reboiler duty stream specified as zero in place of the refluxed absorber. Another option is to feed the liquid product stream directly into a separator, and return the separator vapour product to the bottom stage of the column. Figure 2.6 The column shows the recommended pressure flow specifications for a stand alone refluxed absorber with a partial condenser.-21 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -22 Column Theory ww ThReboiled Absorber A Reboiled Absorber column has a single inlet and two exit streams. When used alone, the Reboiled Absorber has three boundary streams and so requires three Pressure Flow specifications; one pressure and two flow specifications. A pressure specification is always required for the vapour product leaving the column. Distillation Column The basic Distillation column has one inlet and two or three exit streams, depending on the condenser configuration.When used alone, the Distillation column has three or four boundary streams but requires four or five pressure-flow specifications; generally one pressure and three or four flow specifications. The extra pressure-flow specification is required due to the reflux stream, and is discussed in Section - Column-Specific Operations. Figure 2.7 The column shows the recommended pressure flow specifications for a stand alone reboiled absorber.-22 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -23 ww ThThe Three Phase Distillation column is similar to the basic Distillation column except it has three or four exit streams. So when used alone, the Three Phase Distillation column has four to five boundary streams, but requires five or six pressure-flow specifications; generally one pressure and four to five flow specifications. Condenser and Reboiler The following sections provide some recommended pressure- flow specifications for simple dynamic modeling only. The use of flow specifications on reflux streams is not recommended for detailed modeling. If the condenser liquid level goes to zero, a mass flow specification results in a large volumetric flow because the stream is a vapour. It is highly recommended that the proper equipment be added to the reflux stream (for example pumps, valves, and so forth). In all cases, level control for the condenser should be used to ensure a proper liquid level. Figure 2.8 The column shows the recommended pressure-flow specifications for a stand alone three phase distillation column with a partial condenser. The column shows the recommended pressure-flow specifications for a stand alone distillation column with a partial condenser.-23 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -24 Column Theory ww ThPartial Condenser The partial condenser has three exit streams: • overhead vapour • reflux • distillate All three exit streams must be specified when attached to the main tray section. One pressure specification is recommended for the vapour stream, and one flow specification for either of the liquid product streams. The final pressure flow specification can be a second flow specification on the remaining liquid product stream, or the Reflux Flow/Total Liquid Flow value on the Specs page of the Dynamics tab of the condenser can be specified. Fully-Refluxed Condenser The Fully-Refluxed condenser has two exit streams: • overhead vapour • reflux A pressure specification is required for the overhead vapour stream, and a flow specification is required for the reflux stream. Total Condenser A Total condenser has two exit streams: • reflux • distillate There are several possible configurations of pressure flow specifications for this type of condenser. A flow specification can be used for the reflux stream and a pressure flow spec can be used for the distillate stream. Two flow specifications can be used, however, it is suggested that a vessel pressure controller be setup with the condenser duty as the operating variable.-24 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -25 ww ThReboiler The Reboiler has two exit streams: • boilup vapour • bottoms liquid Only one exit stream can be specified. If a pressure constraint is specified elsewhere in the column, this exit stream must be specified with a flow rate. Column Installation The first step in installing a Column is deciding which type you want to install. Your choice depends on the type of equipment (for example, reboilers and condensers) your Column requires. HYSYS has several basic Column templates (pre-constructed column configurations) which can be used for installing a new Column. The most basic Column types are described in the table below. Basic Column Types Icon Description Absorber Tray section only. Liquid-Liquid Extractor Tray section only. Reboiled Absorber Tray section and a bottom stage reboiler. Refluxed Absorber Tray section and an overhead condenser. Distillation Tray section with both a reboiler and condenser. Three Phase Distillation Tray section, three-phase condenser, reboiler. Condenser can be either chemical or hydrocarbon specific.-25 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -26 Column Installation ww ThThere are two ways that you can add a basic Column type to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access UnitOps property view by pressing F12. 2. Click the Prebuilt Columns radio button. 3. From the list of available unit operations, select the column type. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the column type icon you want to install. The Input Expert property view appears. There are also more complex Column types, which are described in the table below. To add a complex column type to your simulation: 1. In the Flowsheet menu, click the Add Operation command. The UnitOps property view appears. You can also access UnitOps property view by pressing F12. Complex Column Types Description 3 Sidestripper Crude Column Tray section, reboiler, condenser, 3 sidestrippers, and 3 corresponding pump around circuits. 4 Sidestripper Crude Column Tray section, reboiler, condenser, an uppermost reboiled sidestripper, 3 steam- stripped lower sidestrippers, and 3 corresponding pump around circuits. FCCU Main Fractionator Tray section, condenser, an upper pump around reflux circuit and product draw, a mid- column two-product-stream sidestripper, a lower pump around reflux circuit and product draw, and a quench pump around circuit at the bottom of the column. Vacuum Reside Tower Tray section, 2 side product draws with pump around reflux circuits and a wash oil-cooled steam stripping section below the flash zone. Refer to Section - Input Experts for more information.-26 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -27 ww Th2. Click the Prebuilt Columns radio button. 3. From the list of available unit operations, select the column type. 4. Click the Add button. The column property view appears. Input Experts Input Experts guide you through the installation of a Column. The Input Experts are available for the following six standard column templates: • Absorber • Liquid-Liquid Extractor • Reboiled Absorber • Refluxed Absorber • Distillation • Three Phase Distillation Details related to each column template are outlined in Section - Templates. Each Input Expert contains a series of input pages whereby you must specify the required information for the page before advancing to the next one. When you have worked through all the pages, you have specified the basic information required to build your column. You are then placed in the Column property view which gives comprehensive access to most of the column features. It is not necessary to use the Input Experts to install a column. You can disable and enable the Input Experts option on the Options page in the Simulation tab of the Session Preferences property view. If you do not use the Input Experts, you move directly to the Column property view when you install a new column. Refer to Chapter 12 - Session Preferences in the HYSYS User Guide for details on how to access the Session Preferences property view.-27 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -28 Column Installation ww ThTemplates HYSYS contains a number of column templates which have been designed to simplify the installation of columns. A Column Template is a pre-constructed configuration or “blueprint” of a common type of Column, including Absorbers, Reboiled and Refluxed Absorbers, Distillation Towers, and Crude Columns. A Column Template contains the unit operations and streams that are necessary for defining the particular column type, as well as a default set of specifications. All Column templates can be viewed by opening the UnitOps property view and selecting the Prebuilt Columns radio button. When you add a new Column, HYSYS gives you a choice of the available templates. Simply select the template that most closely matches your column configuration, provide the necessary input in the Input Expert property view (if applicable), and HYSYS installs the equipment and streams for you in a new Column subflowsheet. Stream connections are already in place, and HYSYS provides default names for all internal streams and equipment. You can then make modifications by adding, removing or changing the names of any streams or operations to suit your specific requirements. Figure 2.9-28 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -29 ww ThClicking the Side Ops button on the final page of the Column Input Expert opens the Side Operations Input Expert wizard, which guides you through the process of adding a side operation to your column. In addition to the basic Column Templates which are included with HYSYS, you can create custom Templates containing Column configurations that you commonly use. HYSYS Column Conventions Column Tray Sections, Overhead Condensers, and Bottom Reboilers are each defined as individual unit operations. Condensers and Reboilers are not numbered stages, as they are considered to be separate from the Tray Section. The following are some of the conventions, definitions, and descriptions of the basic columns: By making the individual components of the column separate pieces of equipment, there is easier access to equipment information, as well as the streams connecting them. Column Component Description Tray Section A HYSYS unit operation that represents the series of equilibrium trays in a Column. Stages Stages are numbered from the top down or from the bottom up, depending on your preference. The top tray is 1, and the bottom tray is N for the top-down numbering scheme. The stage numbering preference can be selected on the Connections page of the Design tab on the Column property view. Overhead Vapor Product The overhead vapour product is the vapour leaving the top tray of the Tray Section in simple Absorbers and Reboiled Absorbers. In Refluxed Absorbers and Distillation Towers, the overhead vapour product is the vapour leaving the Condenser. Overhead Liquid Product The overhead liquid product is the Distillate leaving the Condenser in Refluxed Absorbers and Distillation Towers. There is no top liquid product in simple Absorbers and Reboiled Absorbers.-29 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -30 Column Installation ww ThDefault Replaceable Specifications Replaceable specifications are the values, which the Column convergence algorithm is trying to meet. When you select a particular Column template, or as you add side equipment, HYSYS creates default specifications. You can use the specifications that HYSYS provides, or replace these specifications with others more suited to your requirements. The available default replaceable specifications are dependent on the Basic Column type (template) that you have chosen. The default specifications for the four basic column templates are combinations of the following: • Overhead vapour flowrate • Distillate flowrate • Bottoms flowrate • Reflux ratio • Reflux rate The provided templates contain only pre-named internal streams (streams which are both a feed and product). For instance, the Reflux stream, which is named by HYSYS, is a product from the Condenser and a feed to the top tray of the Bottom Liquid Product The bottom liquid product is the liquid leaving the bottom tray of the Tray Section in simple Absorbers and Refluxed Absorbers. In Reboiled Absorbers and Distillation Columns, the bottom liquid product is the liquid leaving the Reboiler. Overhead Condenser An Overhead Condenser represents a combined Cooler and separation stage, and is not given a stage number. Bottom Reboiler A Bottom Reboiler represents a combined heater and separation stage, and is not given a stage number. The specifications in HYSYS can be set as specifications or changed to estimates. Column Component Description Refer to the Monitor Page and Specs Page in Section - Design Tab for more information.-30 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -31 ww ThTray Section. In the following schematics, you specify the feed and product streams, including duty streams. Absorber Template The only unit operation contained in the Absorber is the Tray Section, and the only streams are the overhead vapour and bottom liquid products. There are no available specifications for the Absorber, which is the base case for all tower configurations. The conditions and composition of the column feed stream, as well as the operating pressure, define the resulting converged solution. The converged solution includes the conditions and composition of the vapour and liquid product streams. The pressure for a tray section stage, condenser or reboiler can be specified at any time on the Pressures page of the Column property view. Figure 2.10 The Liquid-Liquid Extraction Template is identical to the Absorber Template. The remaining Column templates have additional equipment, thus increasing the number of required specifications. A schematic representation of the Absorber.-31 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -32 Column Installation ww ThReboiled Absorber Template The Reboiled Absorber template consists of a tray section and a bottom reboiler. Two additional streams connecting the Reboiler to the Tray Section are also included in the template. When you install a Reboiled Absorber (in other words, add only a Reboiler to the Tray Section), you increase the number of required specifications by one over the Base Case. As there is no overhead liquid, the default specification in this case is the overhead vapour flow rate. Refluxed Absorber Template The Refluxed Absorber template contains a Tray Section and an overhead Condenser (partial or total). Additional material streams associated with the Condenser are also included in the template. For example, the vapour entering the Condenser from the top tray is named to Condenser by default, and the liquid returning to the Tray Section is the Reflux. Figure 2.11 Figure 2.12-32 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -33 ww ThWhen you install a Refluxed Absorber, you are adding only a Condenser to the base case. Specifying a partial condenser increases the number of required specifications by two over the Base Case. The default specifications are the overhead vapour flow rate, and the side liquid (Distillate) draw. Specifying a total condenser results in only one available specification, since there is no overhead vapour product. Either of the overhead vapour or distillate flow rates can be specified as zero, which creates three possible combinations for these two specifications. Each combination defines a different set of operating conditions. The three possible Refluxed Absorber configurations are listed below: • Partial condenser with vapour overhead but no side liquid (distillate) draw. • Partial condenser with both vapour overhead and distillate draws. • Total condenser with distillate but no vapour overhead draw. Distillation Template If you select the Distillation template, HYSYS creates a Column with both a Reboiler and Condenser. The equipment and streams in the Distillation template are therefore a combination of the Reboiled Absorber and Refluxed Absorber Templates Figure 2.13-33 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -34 Column Installation ww ThReflux Ratio The number of specifications for a column with both a Reboiler and Condenser depends on the condenser type. For a partial condenser, you must specify three specifications. For a total condenser, you must specify two specifications. The third default specification (in addition to Overhead Vapor Flow Rate and Side Liquid Draw) is the Reflux Ratio. The Reflux Ratio is defined as the ratio of the liquid returning to the tray section divided by the total flow of the products (see the figure above). If a water draw is present, its flow is not included in the ratio. As with the Refluxed Absorber, the Distillation template can have either a Partial or Total Condenser. Choosing a Partial Condenser results in three replaceable specifications, while a Total Condenser results in two replaceable specifications. The pressure in the tower is, in essence, a replaceable specification, in that you can change the pressure for any stage from the Column property view. Figure 2.14 The pressure remains fixed during the Column calculations.-34 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -35 ww ThThe following table gives a summary of replaceable column (default) specifications for the basic column templates. Three Phase Distillation Template If you select the Three Phase Distillation template, HYSYS creates a Column based on a three phase column model. Templates Vapour Draw Distillate Draw Reflux Ratio Reboiled Absorber X Refluxed Absorber Total Condenser X Partial Condenser X X Distillation Total Condenser X X Partial Condenser X X X Figure 2.15 The same standard column types exist for a three phase system that are available for the “normal” two phase (binary) systems.-35 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -36 Column Installation ww ThUsing the Three Phase Column Input Expert, the initial property view allows you to select from the following options: • Distillation • Refluxed Absorber • Reboiled Absorber • Absorber Each choice builds the appropriate column based on their respective standard (two phase) system templates. If the Input Expert is turned off, installing a Three Phase column template opens a default Column property view for a Distillation type column equipped with a Reboiler and Condenser. The key difference between using the standard column templates and their three phase counterparts lies in the solver that is used. The default solver for three phase columns is the “Sparse Continuation” solver which is an advanced solver designed to handle three phase, non ideal chemical systems, that other solvers cannot. When using the Three Phase Column Input Expert some additional specifications can be required when compared with the standard (binary system) column setups. Clicking the Side Ops button on the final page of the Three Phase Column Input Expert opens the Side Operations Input Expert wizard, which guides you through the process of adding a side operation to your column. Figure 2.16 It requires some expertise to set up, initialize, and solve three phase distillation problems. Additional modeling software applications such as DISTIL, use residue curve maps and distillation region diagrams to determine feasible designs, and can greatly assist in the initial design work. Contact your local AspenTech representative for details. -36 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -37 ww ThColumn Property View The column property view is sectioned into tabs containing pages with information pertaining to the column. The column property view is accessible from the main flowsheet or Column subflowsheet. The column property view is used to define specifications, provide estimates, monitor convergence, view stage-by-stage and product stream summaries, add pump-arounds and side- strippers, specify dynamic parameters and define other Column parameters such as convergence tolerances, and attach reactions to column stages. The column property view is essentially the same when accessed from the main flowsheet or Column subflowsheet. However, there are some differences: • The Connections page in the main flowsheet column property view displays and allows you to change all product and feed stream connections. In addition, you can specify the number of stages and condenser type. • The Connections page in the subflowsheet Column property view (Column Runner) allows you to change the product and feed stream connections, and gives more flexibility in defining new streams. • In the main flowsheet Column property view, the Flowsheet Variables and Flowsheet Setup pages allow you to specify the transfer basis for stream connections, and permit you to view selected column variables. In the Column subflowsheet, the column property view is also known as the Column Runner, and can be accessed by clicking the Column Runner icon. In order to make changes or additions to the Column in the main simulation environment, the Solver should be active. Otherwise HYSYS cannot register your changes. Column Runner icon-37 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -38 Column Property View ww ThColumn Convergence The Run and Reset buttons are used to start the convergence algorithm and reset the Column, respectively. HYSYS first performs iterations toward convergence of the inner and outer loops (Equilibrium and Heat/Spec Errors), and then checks the individual specification tolerances. The Monitor page displays a summary of the convergence procedure for the Equilibrium and Heat/Spec Errors. An example of a converged solution is shown in the following figure: A summary of each of the tabs in the Column property view are in the following sections. Design Tab The following sections detail information regarding the Column property view pages. All pages are common to both the Main Column property view and the Column Runner, unless stated otherwise. Figure 2.17 Column Runner is another name for the subflowsheet Column property view. Refer to the section on the Specification Tolerances for Solver for more information.-38 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -39 ww ThConnections page (Main Flowsheet) The main flowsheet Connections page allows you to specify the name and location of feed streams, the number of stages in the tray section, the stage numbering scheme, condenser type, names of the Column product streams, and Condenser/Reboiler energy streams. The streams shown in this property view reside in the parent or main flowsheet; they do not include Column subflowsheet streams, such as the Reflux or Boilup. In other words, only feed and product streams (material and energy) appear on this page. Figure 2.18 If you have modified the Column Template (for example if you added an additional Tray Section), the Connections page appears differently than what is shown in Figure 2.18.-39 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -40 Column Property View ww ThWhen the column has complex connections, the Connections page changes to the property view shown in the figure below. You can also split the feed streams by selecting the Split checkbox associated to the stream. Click the Edit Trays button to open the Tray Section Details property view. You can edit the number of trays in the column, and add or delete trays after or before the tray number of your choice in this property view. Figure 2.19 Figure 2.19 is an example of the Connections page for a Stripper Crude. Figure 2.20-40 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -41 ww ThConnections page (Column Runner) The Connections page displayed in the Column Runner (inside the Column subflowsheet) appears as shown in the following figure. All feed and energy streams, as well as the associated stage, appear in the left portion of the Connections page. Liquid, vapour, and water product streams and locations appear on the right side of the page. Figure 2.21 If you specify a new stream name in any of the cells, this creates the stream inside the Column. This new stream is not automatically transferred into the main flowsheet. You can connect or disconnect streams from the Connections page, as well as change the stream location.-41 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -42 Column Property View ww ThMonitor Page The Monitor page is primarily used for editing specifications, monitoring Column convergence, and viewing Column profile plots. An input summary, and a property view of the initial estimates can also be accessed from this page. Figure 2.22 HYSYS displays the iteration number, step size, and Equilibrium and Heat/Spec errors in this area during the iteration process. Profiles are where plots of column temperatures, flows, and pressures appear during convergence. The Current checkbox shows the current specs that are being used in the column solution. You cannot select or clear this checkbox. Specification types, the value of each specification, the current calculated value and the weighted error appear here.-42 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -43 ww ThOptional Checks Group In the Optional Checks group, you find the following two buttons: Profile Group During the column calculations, a profile of temperature, pressure or flow appears, and is updated as the solution progresses. Select the appropriate radio button to display the desired variable versus tray number profile. Specifications Group Each specification, along with its specified value, current value, weighted error, and status is shown in the Specifications group. You can change a specified value by typing directly in the associated Specified Value cell. Specified values can also be viewed and changed on the Specs and Specs Summary pages. Any changes made in one location are reflected across all locations. Button Function Input Summary Provides a column input summary in the Trace Window. The summary lists vital tower information including the number of trays, the attached fluid package, attached streams, and specifications. You can click the Input Summary button after you make a change to any of the column parameters to view an updated input summary. The newly defined column configuration appears. View Initial Estimates Opens the Summary page of the Column property view, and displays the initial temperature and flow estimates for the column. You can then use the values generated by HYSYS to enter estimates on the Estimates page. These estimates are generated by performing one iteration using the current column configuration. If a specification for flow or temperature has been provided, it is honoured in the displayed estimates. Refer to Section 1.3 - Object Status & Trace Windows in the HYSYS User Guide for details concerning the Trace Window. Refer to Section - Column Specification Types for a description of the available specification types.-43 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -44 Column Property View ww ThDouble-clicking on a cell within the row for any listed specification opens its property view. In this property view, you can define all the information associated with a particular specification. Each specification property view has three tabs: • Parameters • Summary • Spec Type This property view can also be accessed from both the Specs and Specs Summary pages. Spec Status Checkboxes The status of listed specifications are one of the following types: New specifications can also be added via the Specs page. Figure 2.23 Status Description Active The active specification is one that the convergence algorithm is trying to meet. An active specification always serves as an initial estimate (when the Active checkbox is selected, HYSYS automatically selects the Estimate and Current checkboxes). An active specification always exhausts one degree of freedom. An Active specification is one which the convergence algorithm is trying to meet initially. An Active specification has the Estimate checkbox selected also. Estimate An Estimate is considered an Inactive specification because the convergence algorithm is not trying to satisfy it. To use a specification as an estimate only, clear the Active checkbox. The value then serves only as an initial estimate for the convergence algorithm. An estimate does not exhaust an available degree of freedom. An Estimate is used as an initial “guess” for the convergence algorithm, and is considered to be an Inactive specification. Further details are outlined in the section on the Specification Property View.-44 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -45 ww ThThe degrees of freedom value appears in the Degrees of Freedom field on the Monitor page. When you make a specification active, the degrees of freedom is decreased by one. Conversely, when you deactivate a specification, the degrees of freedom is increased by one. You can start column calculations when there are zero degrees of freedom. Variables such as the duty of the reboiler stream, which is specified in the Workbook, or feed streams that are not completely known can offset the current degrees of freedom. If you feel that the number of active specifications is appropriate for the current configuration, yet the degrees of freedom is not zero, check the conditions of the attached streams (material and energy).You must provide as many specifications as there are available degrees of freedom. For a simple Absorber there are no available degrees of freedom, therefore no specifications are required. Distillation columns with a partial condenser have three available degrees of freedom. Current This checkbox shows the current specs being used by the column solution. When the Active checkbox is selected, the Current checkbox is automatically selected. You cannot alter this checkbox. When Alternate specs are used and an existing hard to solve spec has been replaced with an Alternate spec, this checkbox shows you the current specs used to solve the column. A Current specification is one which is currently being used in the column solution. Completely Inactive To disregard the value of a specification entirely during convergence, clear both the Active and Estimate checkboxes. By ignoring a specification rather than deleting it, you are always able to use it later if required. The current value appears for each specification, regardless of its status. An Inactive specification is therefore ideal when you want to monitor a key variable without including it as an estimate or specification. A Completely Inactive specification is ignored completely by the convergence algorithm, but can be made Active or an Estimate at a later time. Status Description-45 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -46 Column Property View ww ThSpecification Group Buttons The four buttons which align the bottom of the Specifications group allow you to manipulate the list of specs. The table below describes the four buttons. Specs Page Adding and changing Column specifications is straightforward. If you have created a Column based on one of the templates, HYSYS already has default specifications in place. The type of default specification depends on which of the templates you have chosen. Button Action View Move to one of the specification cells and click the View button to display its property view. You can then make any necessary changes to the specification. To change the value of a specification only, move to the Specified Value cell for the specification you want to change, and type in the new value. You can also double-click in a specification cell to open its property view. Add Spec Opens the Column Specifications menu list, from which you can select one or multiple (by holding the CTRL key while selecting) specifications, and then click the Add Spec(s) button. The property view for each new spec is shown and its name is added to the list of existing specifications. Update Inactive Updates the specified value of each inactive specification with its current value. Group Active Arranges all active specifications together at the top of the specifications list. The active specification values are used as initial estimates when the column initially starts to solve. Refer to the section on the Specification Property View for more details. Refer to Section - Column Specification Types for a description of the available specification types. Refer to the Default Replaceable Specifications in Section - Templates for more information.-46 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -47 ww ThColumn Specifications Group The following buttons are available: From the Default Basis drop-down list, you can choose the basis for the new specifications to be Molar, Mass or Volume. Figure 2.24 Button Action View Opens the property view for the highlighted specification. Alternatively, you can object inspect a spec name and select View from the menu. Refer to the section on the Specification Property View for more details. Add Opens the Add Specs property view, from which you can select one or multiple (by holding the CTRL key while selecting) specifications, and then click the Add Spec(s) button. The property view for each new spec is shown, and its name is added to the list of existing specifications. Refer to Section - Column Specification Types for a description of the available specification types. Delete Removes the highlighted specification from the list. Add Specs property view-47 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -48 Column Property View ww ThThe Update Specs from Dynamics button replaces the specified value of each specification with the current value (lined out value) obtained from Dynamic mode. Specification Property View Figure 2.25 is a typical property view of a specification. In this property view, you can define all the information associated with a particular specification. Each specification property view has three tabs: • Parameters • Summary • Spec Type This example shows a component recovery specification which requires the stage number, spec value, and phase type when a Target Type of Stage is chosen. Specification information is shared between this property view, and the specification list on both the Monitor and Specs Summary pages. Altering information in one location automatically updates across all other locations. For example, you can enter the spec value in one location, and the change is reflected across all other locations. Figure 2.25 Specify the stage to which the specification applies. Specify Liquid or Vapor phase for the specification. Provide the name of the component(s) to which the specification applies. Provide basic spec information on the Parameters tab.-48 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -49 ww ThThe Summary tab is used to specify tolerances, and define whether the specification is Active or simply an Estimate. The Spec Type tab (as shown in Figure 2.26) can be used to define specifications as either Fixed/Ranged and Primary/ Alternate. By default, all specifications are initially defined as Fixed and Primary. Advanced solving options available in HYSYS allow the use of both Alternate and Ranged Spec types. The following section further details the advanced solving options available in HYSYS. Ranged and Alternate Specs The reliability of any solution method depends on its ability to solve a wide group of problems. Some specs like purity, recovery, and cut point are hard to solve compared to a flow or reflux ratio spec. The use of Alternate and/or Ranged Specs can help to solve columns that fail due to difficult specifications. Figure 2.26 Specify the interval for use with a Ranged Spec Value. Define as either a Fixed or Ranged Spec. A Ranged Spec allows the solver to meet a Spec over an interval (defined according to the Upper and Lower spec values). Define as either a Primary or Alternate Spec. An Alternate Spec can replace another hard to solve spec in situations where the column is not converging. If the Column solves on an Alternate or Ranged Spec, the status bar reads “Converged - Alternate Specs” highlighted in purple.-49 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -50 Column Property View ww ThConfiguration of these advanced solving options are made by selecting the Advanced Solving Options button located on the Solver page. The advanced solving options are only available for use with either the Hysim I/O or Modified I/O solving methods. Fixed/Ranged Specs For a Fixed Spec, HYSYS attempts to solve for a specific value. For a Ranged Spec, the solver attempts to meet the specified value, but if the rest of the specifications are not solved after a set number of iterations, the spec is perturbed within the interval range provided for the spec until the column converges. Any column specification can be specified over an interval. A Ranged Spec requires both lower and upper specification values to be entered. This option (when enabled), can help solve columns where some specifications can be varied over an interval to meet the rest of the specifications. Primary/Alternate Specs A Primary Spec must be met for the column solution to converge. An Alternate Spec can be used to replace an existing hard to solve specification during a column solution. The solver first attempts to meet an active Alternate spec value, but if the rest of the specifications are not solved after a minimum number of iterations, the active Alternate spec is replaced by an inactive Alternate spec. When the solver attempts to meet a Ranged spec, the Wt. Error becomes zero when the Current Value is within the Ranged interval (as shown on the Monitor page). When an existing spec is replaced by an alternate spec during a column solution, the Current checkbox is cleared for the original (not met) spec and is selected for the alternate spec. The number of active Alternate specs must always equal the number of inactive Alternate specs. Refer to Advanced Solving Options Button in Section - Parameters Tab for further details.-50 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -51 ww ThThis option (when enabled), can help solve columns where some specifications can be ignored (enabling another) to meet the rest of the specifications and converge the column. Specification Tolerances for Solver The Solver Tolerances feature allows you to specify individual tolerances for your Column specifications. In addition to HYSYS converging to a solution for the Heat/Spec and Equilibrium Errors, the individual specification tolerances must also be satisfied. HYSYS first performs iterations until the Heat/Spec (inner loop), and Equilibrium (outer loop) errors are within specified tolerances. The Column specifications do not have individual tolerances during this initial iteration process; the specification errors are “lumped” into the Heat/Spec Error. Once the Heat/Spec and Equilibrium conditions are met, HYSYS proceeds to compare the error with the tolerance for each individual specification. If any of these tolerances are not met, HYSYS iterates through the Heat/Spec, and Equilibrium loops again to produce another converged solution. The specification errors and tolerances are again compared, and the process continues until both the inner/ outer loops and the specification criteria are met. Specific Solver Tolerances can be provided for each individual specification. HYSYS calculates two kinds of errors for each specification: • an absolute error • a weighted error Both Ranged or Alternate Specs must be enabled and configured using the Advanced Solving Options Button located on the Solver page of the Parameters tab before they can be applied during a column solution. When the Weighted and Absolute Errors are less than their respective tolerances, an Active specification has converged. For more information, refer to Section - Parameters Tab.-51 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -52 Column Property View ww ThThe absolute error is simply the absolute value of the difference between the calculated and specified values: The Weighted Error is a function of a particular specification type. When a specification is active, the convergence algorithm is trying to meet the Weighted Tolerances (Absolute Tolerances are only used if no Weighted Tolerances are specified, or the weighted tolerances are not met). Therefore, both the weighted and absolute errors must be less than their respective tolerances for an active specification to converge. HYSYS provides default values for all specification tolerances, but any tolerance can be changed. For example, if you are dealing with ppm levels of crucial components, composition tolerances can be set tighter (smaller) than the other specification tolerances. If you delete any tolerances, HYSYS cannot apply the individual specification criteria to that specification, and Ignore appears in the tolerance input field. The specification tolerance feature is simply an “extra” to permit you to work with individual specifications and change their tolerances if desired. Specification Details Group For a highlighted specification in the Column Specifications group, the following information appears: • Spec Name • Convergence Condition. If the weighted and absolute errors are within their tolerances, the specification has converged and Yes appears. • Status. You can manipulate the Active and Use As Estimate checkboxes. • Dry Flow Basis. Draw specifications are calculated on a dry flow basis by selecting the Dry Flow Basis checkbox. This option is only available for draw specifications. The checkbox is greyed out if it does not apply to the specification chosen. Errorabsolute = |Calculated Value - Specified Value| (2.3) Refer to the Spec Status Checkboxes for further details concerning the use of these checkboxes.-52 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -53 ww Th• Spec Type. You can select between Fixed/Ranged and Primary/Alternate specs. • Specified and Current Calculated Values. • Weighted/Absolute Tolerance and Calculated Error. Specs Summary Page The Specs Summary page lists all Column specifications available along with relevant information. This specification information is shared with the Monitor page and Specs page. Altering information in one location automatically updates across all other locations. Subcooling Page The Subcooling page allows you to specify subcooling for products coming off the condenser of your column. You can specify the condenser product temperature or the degrees to subcool. For columns without condensers, such as absorbers, You can edit any specification values (in the Column property view) shown in blue. Figure 2.27 You can edit any specification details shown in blue. You can double-click in a specification cell to open its property view. Refer to the section on the Ranged and Alternate Specs for more details. Refer to the section on the Specification Property View for more details.-53 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -54 Column Property View ww Ththis page requires no additional information. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. Parameters Tab The Parameters tab shows the column calculation results, and is used to define some basic parameters for the Column solution. The Parameters tab consists of six pages: • Profiles • Estimates • Efficiencies • Solver • 2/3 Phase • Amines Profiles Page The Profiles page shows the column pressure profile, and provides estimates for the temperature, net liquid and net vapour flow for each stage of the column. You can specify tray estimates in the Temperature column, Net Liquid column and Net Vapour column, or view the values calculated by HYSYS. The Subcooling page is not available for Liquid-Liquid Extractor. For more information, refer to Section 1.3.5 - Notes Page/Tab.-54 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -55 ww ThThe graph in Figure 2.28 depicts the pressure profile across the column. Use the radio buttons in the Flow Basis group to select the flow type you want displayed in the Net Liquid and Net Vapour columns. The Flow Basis group contains three radio buttons: • Molar • Mass • Volume The buttons in the Steady State Profiles group are defined as follows: Figure 2.28 At least one iteration must have occurred for HYSYS to convert between bases. In this way, values for the compositions on each tray are available. Button Function Update from Solution Transfers the current values that HYSYS has calculated for the trays into the appropriate cells. Estimates that have been Locked (displayed in blue) are not updated. The Column Profiles page on the Performance tab allows you to view all the current values. Clear Deletes values for the selected tray.-55 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -56 Column Property View ww ThAlthough the Profiles page is mainly used for steady state simulation, it does contain vital information for running a column in dynamics. One of the most important aspects of running a column in dynamics is the pressure profile. While a steady state column can run with zero pressure drop across a tray section, the dynamic column requires a pressure drop. In dynamics, an initial pressure profile is required before the column can run. This profile can be from the steady state model or can be added in dynamics. If a new tray section is created in Dynamic mode, the pressure profile can be obtained from the streams if not directly specified. In either case, the closer the initial pressure profile is to the one calculated while running in dynamics, the fewer problems you encounter. Estimates Page The Estimates page allows you to view and specify composition estimates. When you specify estimates on stages that are not adjacent to each other, HYSYS cannot interpolate values for intermediate stages until the solution algorithm begins. Clear All Trays Deletes values for all trays. Lock Changes all red values (unlocked estimates, current values, interpolated values) to blue (locked), which means that they cannot be overwritten by current values when the Update from Solution button is clicked. Unlock Changes all blue values (locked) to red (unlocked). Unlocked values are overwritten by current values when the Update from Solution button is clicked. Stream Estimates Displays the temperature, molar flow, and enthalpy of all streams attached to the column operation. To see the initial estimates generated by HYSYS, click the View Initial Estimates button on the Monitor page. Estimates are NOT required for column convergence. Button Function-56 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -57 ww ThYou can specify tray by tray component composition estimates for the vapour phase or liquid phase. Each composition estimate is on a mole fraction basis, so values must be between 0 and 1. HYSYS interpolates intermediate tray component values when you specify compositions for non-adjacent trays. The interpolation is on a log basis. Unlike the temperature estimates, the interpolation for the compositions does not wait for the algorithm to begin. Select either the Vap or Liq radio button in the Phase group to display the table for the vapour or liquid phase, respectively. The Composition Estimates group has the following buttons: Figure 2.29 Button Action Clear Tray Deletes all values, including user specified (blue) and HYSYS generated (red), for the selected tray. HYSYS does not ask for confirmation before deleting estimates. Clear All Trays Deletes all values for all trays. HYSYS does not ask for confirmation before deleting estimates. Update Transfers the current values which HYSYS has calculated for tray compositions into the appropriate cells. Estimates that have been locked (shown in blue) cannot be updated.-57 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -58 Column Property View ww ThEfficiencies Page The Efficiencies page allows you to specify Column stage efficiencies on an overall or component-specific basis. Efficiencies for a single stage or a section of stages can easily be specified. HYSYS uses a modified Murphree stage efficiency. All values are initially set to 1.0, which is consistent with the assumption of ideal equilibrium or theoretical stages. If this assumption is not valid for your column, you have the option of specifying the number of actual stages, and changing the efficiencies for one or more stages. Restore Removes all HYSYS updated values from the table, and replaces them with your estimates and their corresponding interpolated values. Any cells that did not contain estimates or interpolated values are shown as. This button essentially reverses the effect of the Update button. If you had entered some estimate values, click the Unlock Estimates button, and click the Update button. All the values in the table appear in red. You can restore your estimated values by clicking the Restore button. Normalize Trays Normalizes the values on a tray so that the total of the composition fractions equals 1. HYSYS ignores cells, and normalizes the compositions on a tray provided that there is at least one cell containing a value. Lock Estimates Changes all red values (unlocked estimates, current values, interpolated values) to blue (locked), which means that they cannot be overwritten by current values when the Update button is clicked. Unlock Estimates Changes all blue values (locked) to red (unlocked). Unlocked values are overwritten by current values when the Update button is clicked. Fractional efficiencies cannot be given for the condenser or reboiler stages, nor should they be set for feed or draw stages. The functionality of this page is slightly different when working with the Amines Property Package. Button Action Refer to the section on Special Case - Amines Property Package for more information. -58 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -59 ww ThTo specify an efficiency to multiple cells, highlight the desired cells, enter a value in the Eff. Multi-Spec field, and click the Specify button. The data table on the Efficiency page gives a stage-by-stage efficiency summary. Overall stage efficiencies can be specified by selecting the Overall radio button in the Efficiency Type group, and entering values in the appropriate cells. Component-specific efficiencies can be specified by selecting the Component radio button, and entering values in the appropriate cells. Figure 2.30 The efficiencies are fractional. In other words, an efficiency of 1.0 corresponds to 100% efficiency.-59 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -60 Column Property View ww ThSpecial Case - Amines Property Package When solving a column for a case using the Amines Property Package, HYSYS always uses stage efficiencies for H2S and CO2 component calculations. If these are not specified on the Efficiencies page of the Column property view, HYSYS calculates values based on the tray dimensions. Tray dimensions can be specified on the Amines page of the Parameters tab. If column dimensions are not specified, HYSYS uses its default tray values to determine the efficiency values. If you specify values for the CO2 and H2S efficiencies, these are the values that HYSYS uses to solve the column. If you want to solve the column again using efficiencies generated by HYSYS, click the Reset H2S, CO2 button, which is available on the Efficiencies page. Run the column again, and HYSYS calculates and displays the new values for the efficiencies. Select the Transpose checkbox to change the component efficiency matrix so that the rows list components and the columns list the stages. The Reset H2S, CO2 button, and the Transpose checkbox are available only if the Efficiency Type is set to Component. For more information on the Amines Property Packages, refer to Appendix C - Amines Property Package of the HYSYS Simulation Basis guide.-60 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -61 ww ThSolver Page You can manipulate how the column solves the column variables on the Solver page. Solving Options Group Specify your preferences for the column solving behaviour in the Solving Options group. Figure 2.31 The Solving Method Group, Acceleration Group, and Damping Group will have different information displayed according to the options selected within the group. Figure 2.32-61 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -62 Column Property View ww ThMaximum Number of Iterations The Column convergence process terminates if the maximum number of iterations is reached. The default value is 10000, and applies to the outer iterations. If you are using Newton's method, and the inner loop does not converge within 50 iterations, the convergence process terminates. Equilibrium and Heat/Spec Tolerances Convergence tolerances are pre-set to very tight values, thus ensuring that regardless of the starting estimates (if provided) for column temperatures, flow rates, and compositions, HYSYS always converges to the same solution. However, you have the option of changing these two values if you want. Default values are: • Inner Loop. Heat and Spec Error: 5.000e-04 • Outer Loop. Equilibrium Error: 1.000e-05 Because the default values are already very small, you should use caution in making them any smaller. You should not make these tolerances looser (larger) for preliminary work to reduce computer time. The time savings are usually minor, if any. Also, if the column is in a recycle or adjust loop, this could cause difficulty for the loop convergence. Equilibrium Error The value of the equilibrium error printed during the column iterations represents the error in the calculated vapour phase mole fractions. The error over each stage is calculated as one minus the sum of the component vapour phase mole fractions. This value is then squared; the total equilibrium error is the sum of the squared values. The total equilibrium error must be less than 0.00001 to be considered a converged column.-62 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -63 ww ThHeat and Spec Error The heat and specification error is the sum of the absolute values of the heat error and the specification error, summed over each stage in the tower. This total value is divided by the number of inner loop equations. The heat error contribution is the heat flow imbalance on each tray divided by the total average heat flow through the stage. The specification error contribution is the sum of each individual specification error divided by an appropriate normalization factor. • For component(s) flow, the normalization factor is the actual component(s) flow. • For composition, it is the actual mole fraction. • For vapour pressure and temperature, it is a value of 5000. • And so forth. The total sum of heat and spec errors must be less than 0.0005 to be considered a converged column. The allowed equilibrium error and heat and spec error are tighter than in most programs, but this is necessary to avoid meta-stable solutions, and to ensure satisfactory column heat and material balances. Save Solution as Initial Estimate This option is on by default, and it saves converged solutions as estimates for the next solution.-63 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -64 Column Property View ww ThSuper Critical Handling Model Supercritical phase behaviour occurs when one or more Column stages are operating above the critical point of one or more components. During the convergence process, supercritical behaviour can be encountered on one or more stages in the Column. If HYSYS encounters supercritical phase behaviour, appropriate messages appear in the Trace Window. HYSYS cannot use the equation of state or activity model in the supercritical range, so an alternate method must be used. You can specify which method you want HYSYS to use to model the phase behaviour. There are three choices for supercritical calculations: Trace Level The Trace Level defines the level of detail for messages displayed in the Trace Window, and can be set to Low, Medium, or High. The default is Low. Model Description Simple K The default method. HYSYS calculates K-values for the components based on the vapour pressure model being used. Using this method, the K-values which are calculated are ideal K-values. Decrease Pressure When supercritical conditions are encountered, HYSYS reduces the pressure on all trays by an internally determined factor, which can be seen in the Trace Window when the Verbose option is used. This factor is gradually decreased until supercritical conditions no longer exist on any tray, at which point, the pressure in the column is gradually increased to your specified pressure. If supercritical conditions are encountered during the pressure increase, the pressure is once again reduced and the process is repeated. Adjacent Tray When supercritical conditions are encountered on a tray, HYSYS searches for the closest tray above which does not have supercritical behaviour. The non- supercritical conditions are substituted in the phase calculations for the tray with supercritical conditions. Refer to Section 1.3 - Object Status & Trace Windows in the HYSYS User Guide for details on the Trace Window.-64 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -65 ww ThInitialize from Ideal K’s When this checkbox is selected, HYSYS initializes its column solution using ideal K values which are calculated from vapour pressure correlations. The ideal K-value option, which is also used by HYSIM, increases the compatibility between HYSIM and HYSYS. By default, the Initialize from Ideal K's checkbox is cleared. HYSYS uses specified composition estimates or generates estimates to rigorously calculate K-values. Two Liquids Check Based on This option allows you to specify a check for two liquid phases in the column. The check is based on one of the following criteria: • No 2 Liq Check. Disables the two liquid check. • Tray Liquid Fluid. The calculation is based on the composition of the liquid in the column. • Tray Total Fluid. The calculation is based on the overall composition of the fluid in the column. Tighten Water Tolerance When this checkbox is selected, HYSYS increases the contribution of the water balance error to the overall balance error in order to solve columns with water more accurately. The default setting for this checkbox is cleared.-65 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -66 Column Property View ww ThSolving Method Group The Solving Method drop-down list allows you to select the column solution method. The display field, which appears below the drop-down list, provides explanations for each method, and is restated here: Inside-Out With the “inside-out” based algorithms, simple equilibrium and enthalpy models are used in the inner loop to solve the overall component and heat balances as well as any specifications. The outer loop updates the simple thermodynamic models with rigorous model calculations. Figure 2.33 Method Explanation HYSIM Inside- Out General purpose method, which is good for most problems. Modified HYSIM Inside-Out General purpose method, which allows mixer, tee, and heat exchangers inside the column subflowsheet. Only a simple Heat Exchanger Model (Calculated from Column) is available in the Column subflowsheet. The Simple Rating, End-Point, and Weighted models are not available. Newton Raphson Inside-Out General purpose method, which allows liquid-phase kinetic reactions inside the Column subflowsheet. Sparse Continuation Solver An equation based solver. It supports two liquid phases on the trays, and its main use is for solving highly non- ideal chemical systems and reactive distillation. Simultaneous Correction Simultaneous method using dogleg methods. Good for chemical systems. This method also supports reactive distillation. OLI Solver Only used to calculate the column unit operation in an electrolyte system.-66 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -67 ww ThSparse Continuation Solver Control Panel When the Sparse Continuation Solver is selected, the Control button becomes available. This button brings up the Sparse Continuation Solver Control Panel. This panel gives you the following options: • Liquid Fugacity Model - Temp Only - Temp and Composition - Property Package • Vapour Fugacity Model - Temp Only - Temp and Composition - Property Package • Liquid Enthalpy Model - Simple Liquid Model - Property Package • Vapour Enthalpy Model - Simple Liquid Model - Property Package Select the Chemical Defaults radio button in the Phase Fugacity Models group to use the following default settings: • Liquid Fugacity Model - Property Package • Vapour Fugacity Model - Temp and Composition • Liquid Enthalpy Model - Simple Liquid Model • Vapour Enthalpy Model - Simple Vapour Model Select the Hydrocarbon Defaults radio button in the Phase Fugacity Models group to use the following default settings: • Liquid Fugacity Model - Temp and Composition • Vapour Fugacity Model - Temp Only • Liquid Enthalpy Model - Simple Liquid Model • Vapour Enthalpy Model - Simple Vapour Model Note: Whenever you modify any of the default settings the User Specified radio button becomes active. General Features of the Solving Methods The following table displays the general features of all the -67 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -68 Column Property View ww ThHYSYS column solving methods. HYSIM I/O Modified HYSIM I/O Newton Raphson I/O Sparse Continuation Simultaneous Correction OLI Component Efficiency Handling Yes Yes No Yes No Yes Total Efficiency Handling Yes Yes No Yes No Yes Additional Side Draw Yes Yes Yes Yes Yes Yes Vapour Bypass Yes Yes No Yes No No Pump Arounds Yes Yes No Yes No Yes Side Stripper Yes Yes No Yes No No Side Rectifier Yes Yes No Yes No No Mixer & Tee in Sub- flowsheet No Yes No No No No Three Phase Yes (water draw) Yes (water draw) No Yes No Yes Chemical (reactive) No No Yes Yes Yes Inter nal reacti ons-68 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -69 ww ThAcceleration Group When selected, the Accelerate K value & H Model Parameters checkbox displays two fields, which relate to an acceleration program called the Dominant Eigenvalue Method (DEM). The DEM is a numerical solution program, which accelerates convergence of the simple model K values and enthalpy parameters. It is similar to the Wegstein accelerator, with the main difference being that the DEM considers all interactions between the variables being accelerated. The DEM is applied independently to each stage of the column. The listed DEM parameters include: Figure 2.34 By default, the Accelerate K value & H Model Parameters checkbox is cleared. Use the acceleration option if you find that the equilibrium error is decreasing slowly during convergence. This should help to speed up convergence. Notice that the Accelerate K value & H Model Parameters checkbox should NOT be selected for AZEOTROPIC columns, as convergence tends to be impeded. Parameter Description Acceleration Mode Select either Conservative or Aggressive. With the Conservative approach, smaller steps are taken in the iterative procedure, thus decreasing the chance of a bad step. Maximum Iterations Queued Allows you to choose the number of data points from previous iterations that the accelerator program uses to obtain a solution.-69 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -70 Column Property View ww ThDamping Group Choose the Damping method by selecting either the Fixed or Adaptive radio button. Fixed Damping If you select the Fixed radio button, you can specify the damping factor. The damping factor controls the step size used in the outer loop when updating the simple thermodynamic models used in the inner loop. For the vast majority of hydrocarbon-oriented towers, the default value of 1.0 is appropriate, which permits a full adjustment step. However, should you encounter a tower where the heat and specification errors become quite small, but the equilibrium errors diverge or oscillate and converge very slowly, try reducing the damping factor to a value between 0.3 and 0.9. Alternatively, you could enable Adaptive Damping, allowing HYSYS to automatically adjust this factor. There are certain types of columns, which definitely require a special damping factor. Use the following table as a guideline in setting up the initial value. Figure 2.35 Changing the damping factor has an effect on problems where the heat and spec error does not converge. Type of Column Damping Factor All hydrocarbon columns from demethanizers to debutanizers to crude distillation units 1.0 Non-hydrocarbon columns including air separation, nitrogen rejection 1.0-70 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -71 ww ThAs shown in the table above, an azeotropic column requires the azeotrope checkbox to be enabled. There are two ways to indicate to HYSYS that you are simulating an azeotropic column: • Enter a negative damping factor, and HYSYS automatically selects the Azeotropic checkbox. • Enter a positive value for the damping factor, and select the Azeotropic checkbox. Most petrochemical columns including C2= and C3= splitters, BTX columns 1.0 Amines absorber 1.0 Amines regenerator, TEG strippers, sour water strippers 0.25 to 0.50 Highly non-ideal chemical columns without azeotropes 0.25 to 0.50 Highly non-ideal chemical columns with azeotropes 0.50 to -1.0* The Azeotropic checkbox on the Solver page of the Parameters tab must be selected for an azeotropic column to converge. The absolute value of the damping factor is always displayed. Type of Column Damping Factor-71 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -72 Column Property View ww ThAdaptive Damping If you select the Adaptive radio button, the Damping matrix displays three fields. HYSYS updates the damping factor as the column solution is calculated, depending on the Damping Period and convergence behaviour. Initialization Algorithm Radio Buttons There are two types of method for the initialization algorithm calculation: • Standard Initialization radio button uses the tradition initialization algorithm in Hysys. • Program Generates Estimations radio button uses a new functionality that handles the cases where the traditional initialization does not. Damping Period Description Initial Damping Factor Specifies the starting point for adaptive damping. Adaptive Damping Period The default Adaptive Damping Period is ten. In this case, after the tenth iteration, HYSYS looks at the last ten errors to see how many times the error increased rather than decreased. If the error increased more than the acceptable tolerance, this is an indication that the convergence is likely cycling, and the current damping factor is then multiplied by 0.7. Every ten iterations, the same analysis is done to see if the damping factor should be further decreased. Alternatively, if the error increased only once in the last period, the damping factor is increased to allow for quicker convergence. Reset Initial Damping Factor If this checkbox is selected, the current damping factor is used the next time the column is solved. If this checkbox is cleared, the damping factor before adaptive damping was applied is used. Figure 2.36-72 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -73 ww ThThe following list situations when the Program Generates Estimations (PGE) initialization method is used: • The PGE initialization handles systems with more than 25 components while the standard initialization does not handle systems with more than 25 components without the user’s initial estimation. • When column does not converge with the standard initialization method (default), switching to PEG may converge the column. The new algorithm eliminates the discrepancy in the temperature and component estimates, which may exist in standard initialization. Initial Estimate Generator Parameters You can enable the initial estimate generator (IEG) by selecting the Dynamic Integration for IEG checkbox. The IEG then performs iterative flash calculations (NRSolver, PV, and PH) to provide initial estimates for the temperature and composition profiles. No user estimates are required when the Dynamic Integration for IEG checkbox is selected. Click the Dynamic Estimates Integrator button, and the Col Dynamic Estimates property view appears as shown in the figure below. Figure 2.37-73 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -74 Column Property View ww ThCol Dynamic Estimates Property View The Col Dynamic Estimates property view allows you to further define the dynamic estimates parameters. You can set parameters for the time period over which the dynamic estimates are calculated, as well as set the calculation tolerance. A selected Active checkbox indicates that the Dynamic Integration for IEG is on. Select either the Adiabatic or Isothermal radio button to set the dynamic initialization flash type. If you want to generate the dynamic estimates without running the column, you can do so from this property view by clicking the Start button. If you want to stop calculations before the specified time has elapsed, click the Stop button. You do not have to manually click the Start button to generate the estimates; if the Dynamic Integration for IEG option is active, HYSYS generates them automatically whenever the column is running. The Shortcut Mode checkbox allows you to bypass this step once a set of estimates is generated, that is, once the column has converged. Figure 2.38 If you are running simulation with an iterative solving procedure where the column has to be calculated several times, it is a good idea to select this option to save on calculation time.-74 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -75 ww ThAdvanced Solving Options Button When you click the Advanced Solving Options button, the Advanced Solving Options property view appears. On the Advanced Solving Options property view, each solving option (for exmple, Alternate, Ranged, and Autoreset) has a solving priority and also a checkbox option. To use a particular solving option, you have to select the corresponding checkbox. You must also specify the priority of the solving method. This is the order in which the solving options are executed (either first, second or third). Advanced solving options cannot be used until the minimum number of iterations are met. If the column is not solved after the minimum number of iterations, the solver switches to an advanced solving option according to the solving priority. This process is repeated until all the solving options have been attempted or the column converges. Figure 2.39 All the Alternate active specs can be replaced on an individual spec basis or all specs simultaneously. The alternative (active) spec with the larger error is replaced with an alternative inactive spec with minimum error. The “use” checkboxes must be selected in order to enable a particular option. These checkboxes are only enabled if the corresponding spec type exists. The order in which the solving options are executed is based on the priority. If the Column converges on an Alternate or Ranged Spec, the status bar reads “Converged - Alternate Specs” highlighted in purple.-75 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -76 Column Property View ww Th2/3 Phase Page The 2/3 Phase page is relevant only when you are working with three-phase distillation. On this page, you can check for the presence of two liquid phases on each stage of your column. The Liquid Phase Detection table lists the liquid molar flow rates on each tray of the tray section, including the reboiler and the condenser. In order for HYSYS to check for two liquid phases on any given stage, select the checkbox in the Check column. If a second liquid phase is calculated, this is indicated in the Detected column, and by a calculated flowrate value in the L2Rate When a column is in recycle, by default, the solver switches to the original set of specs after each recycle iteration or the next time the column solves. Figure 2.40 This page is not available for Liquid-Liquid Extractor.-76 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -77 ww Thcolumn. The buttons in the Liquid Phase Detection group serve as aids in selecting and de-selecting the trays you want to check. The 2nd Liquid Type group allows you to specify the type of calculation HYSYS performs when checking for a second liquid phase. When the Pure radio button is selected, HYSYS checks only for pure water as the second phase. This helps save calculation time when working with complex hydrocarbon systems. When you want a more rigorous calculation, select the Rigorous radio button. Auto Water Draws Button The Auto Water Draws (AWD) option allows for the automatic adding and removing of total aqueous phase draws depending on the conditions in the converged column. AWD updating process is based on direct check of stage fluid phases. The direct check follows the Two Liquids Check Based on control criteria for detecting the aqueous phase. AWD mode is not available if No 2 Liq Check option is selected. Checking for liquid phases in a three phase distillation tower greatly increases the solution time. Typically, checking the top few stages only, provides reasonable results. By default, HYSYS selects Pure for all hydrocarbon, and Rigorous for all chemical based distillations. This default selection criteria is based on the type of fluid package used but you can always change it. The Auto Water Draws facility is available for IO and MIO solvers. The Two Liquids Check Based on drop-down list is located in the Parameters tab of the Solver page in the Solving Options group.-77 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -78 Column Property View ww ThTo manipulate the AWD option, click the Auto Water Draws button to open the Auto Water Draws property view. The Auto Water Draws property view contains the following objects: The Auto Water Draws button is available in both column subflowsheet and main flowsheet. Figure 2.41 Object Description On Select this checkbox to activate the Auto Water Draws mode. Threshold The threshold value allows variation of the condition for 2nd liquid phase. The default value in this cell is 0.001 (same as for Two Liquids Check based on control). If you delete the value in this cell, the threshold is set to minimum possible value. Keep draws If this checkbox is selected, the added draws are not removed. Preserve estimates If this checkbox is selected, the converged values are preserved as estimates for the next column run. Reset If this checkbox is selected, the column Reset option is performed before each column run. Strategy There are three options of strategy to select from in the Strategy group: • All. All required changes in water draw configuration are done simultaneously. • From Top.Updates on the topmost stage from required is performed. • From Bottom. Updates on the bottommost stage from required is performed. The All option results typically in multiple water draws with small flows, and the From Top or From Bottom option results typically in fewer water draws. To AWD All existing water draws are converted to AWDs. -78 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -79 ww ThTwo more columns are added in the table on the 2/3 Phase page when in Auto Water Draws mode. These two columns are called AWD and No AWD • Set AWD mode for attached water draw by selecting the checkboxes under the AWD column. • If the checkbox in the No AWD column is selected, no AWD will be attached to corresponding stage. Amines Page The Amines page appears on the Parameters tab only when working with the Amines Property Package. There are two groups on the Amine page: • Tray Section Dimensions for Amine Package • Approach to Equilibrium Results Tray Section Dimensions for Amine Package When solving the column using the Amines package, HYSYS always takes into account the tray efficiencies, which can either be user-specified, on the Efficiencies page, or calculated by HYSYS. Calculated efficiency values are based on the tray dimensions specified. The Amines page lists the tray section dimensions of your column, where you can specify these values that are used to determine the tray efficiencies in the Tray Section Dimensions for Amine Package group. From AWD Converts all AWDs to regular draws. Restore Restores the last successful (in other words, column equation were solved) AWD configuration. Delete Deletes all AWDs. The Amines Property Package is an optional property package that must be purchased in addition to the base version of HYSYS. Object Description For more information on the Amines Property Package, refer to the Appendix C - Amines Property Package in the HYSYS Simulation Basis guide.-79 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -80 Column Property View ww ThThe list includes: • Tray Section • Weir Height • Weir Length • Tray Volume • Tray Diameter If tray dimensions are not specified, HYSYS uses the default tray dimensions to determine the efficiency values. Approach to Equilibrium Results Approach to Equilibrium values are used for the design, operation, troubleshooting, and de-bottlenecking for the absorption and regeneration columns in an amine plant. When you are modeling an amine column in HYSYS, you can calculate the Approach to Equilibrium values after the column converges. With this capability, you can adjust the flowrate of amine to achieve a certain Approach to Equilibrium value recommended by literature or in-house experts for the amine column. The extension is compatible with all of the major amine and mixtures of amines (in other words, MEA, DEA, TEA, DGA, DIPA, MDEA, and any mixtures of these amines). The Approach to Equilibrium extension calculates the Approach to Equilibrium value of rich amine from the bottom of the absorber column in two methods: • Partial Pressure • Amine Molar Loading Method 1 Partial Pressure In this method, the Approach to Equilibrium is defined as the partial pressure of the acid gas in the rich amine stream exiting the absorber relative to the partial pressure of the acid gas in the main feed gas stream entering the absorber. The extension can only be used on a pre-converged amine treating unit simulation with the Amine Property Package.-80 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -81 ww ThThe Approach to Equilibrium calculation are as follows: The Approach to Equilibrium results based on H2S and CO2 are expressed in percentages. When both H2S and CO2 are present, the highest Approach to Equilibrium percentage is usually reported, although both values should be reported. Amine Molar Loading Amine Molar Loading is defined as the loading of the rich amine solution leaving the absorber divided by the equilibrium amine loading, assuming that the amine is at equilibrium with the feed gas and is at the same temperature as the rich amine leaving the absorber. The temperature of the rich amine and the amine in equilibrium with the feed gas are the same. The result is expressed as a percentage as follows: In general, the Approach to Equilibrium value calculated by the Partial Pressure method is greater than the one calculated by the Amine Molar Loading method. (2.4) (2.5) (2.6) H2S 100% ppH2Srich amine exiting the absorber ppH2Sfeed gas entering the absorber ----------------------------------------------------------------------------------- ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ ⋅= CO2 100% ppCO2rich amine exiting the absorber ppCO2feed gas entering the absorber ------------------------------------------------------------------------------------ ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ ⋅= Approach to Equilibrium 100% Rich amine loading in mole AG mole of amine⁄ Equilibrium loading in mole AG mole of amine⁄ -------------------------------------------------------------------------------- ⎝ ⎠ ⎜ ⎟ ⎜ ⎟ ⎜ ⎟ ⎛ ⎞ ⋅=-81 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -82 Column Property View ww ThSide Ops Tab Side strippers, side rectifiers, pump arounds, and vapour bypasses can be added to the Column from this tab. To install any of these Side Operations, click the Side Ops Input Expert button or on the appropriate Side Ops page, click the Add button. • If you are using the Side Ops Input Expert, a wizard guides you through the entire procedure of adding a side operation to your column. • If you are using the Add button, complete the form which appears, and then click the Install button. Specifications that are created when you add a side operation are automatically added to the Monitor page and Specs page. For instance, when you add a side stripper, product draw and boilup ratio specs are added. As well, all appropriate operations are added; for example, with the side stripper (reboiled configuration), a side stripper tray section and reboiler are installed in the Column subflowsheet. You can view or delete any Side Operation simply by positioning the cursor in the same line as the Operation, and clicking the View or Delete button. Side Strippers Page You can install a reboiled or steam-stripped side stripper on this page. You must specify the number of stages, the liquid draw stage (from the Main Column), the vapour return stage (to the Main Column), and the product stream and flow rate (on a molar, mass or volume basis). For the reboiled configuration, you must specify the boilup ratio, which is the ratio of the vapour to the liquid leaving the reboiler. If you are specifying Side Operations while in the Main simulation environment, make sure that the Solver is Active. Otherwise, HYSYS cannot register your changes. The Side Ops tab is not available in the Liquid-Liquid Extractor. Some solver methods do not allow side ops.Refer to the table in the section on the General Features of the Solving Methods for more information.-82 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -83 ww ThFor the steam-stripped configuration it is necessary to specify the steam feed. The property view of the side stripper is shown in the figure below. When you click the Install button, a side stripper tray section is installed, as well as a reboiler if you selected the Reboiled configuration. By default, the tray section is named SS1, the reboiler is named SS1_Reb, and the reboiler duty stream is named SS1_Energy. As you add additional Side strippers, the index increases (for example SS2, SS3, and so forth). Figure 2.42 To change the side stripper draw and return stages from the Column property view, the Solver must be Active in the Main simulation environment.-83 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -84 Column Property View ww ThSide Rectifiers Page As with the side stripper, you must specify the number of stages, the liquid draw stage, and the vapour return stage. The vapour and liquid product rates, as well as the reflux ratio are also required. These specifications are added to the Monitor page and Specs page of the Column property view. When you install the side rectifier, a side rectifier tray section and partial condenser are added. By default, the tray section is named SR_1, the condenser is named SR_1_Cond, and the condenser duty stream is named SR_1_Energy. Figure 2.43-84 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -85 ww ThPump Arounds Page When you install the pump around, a Cooler is also installed. The default pump around specifications are the pump around rate and temperature drop. These are added on the Monitor page and Specs page of the Column property view. After you click the Install button, the Pump Around property view changes significantly, as shown in the figure below, allowing you to change pump around specifications, and view pump around calculated information. Vap Bypasses Page As with the Pump Around, it is necessary to specify the draw and return stage, as well as the molar flow and duty for the vapour bypass. When you install the vapour bypass, the draw temperature and flowrate appear on the vapour bypass property view. Figure 2.44 When installing a Pump Around, it is necessary to specify the draw stage, return stage, molar flow, and duty.-85 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -86 Column Property View ww ThThe vapour bypass flowrate is automatically added as a specification. The figure below shows the vapour bypass property view once the side operation has been installed. Side Draws Page The Side Draws page allows you to view, and edit information regarding the side draw streams in the column. The following is the information included on this page: • Draw Stream • Draw Stage • Type (Vapour, Liquid or Water) • Mole Flow • Mass Flow • Volume Flow Rating Tab The Rating tab has several pages, which are described in the Figure 2.45-86 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -87 ww Thtable below. Page Description Tray Sections Provides information regarding tray sizing. On this page, you can specify the following: • Tray Section (Name) • Uniform Section. When this option is selected all tray stages have the same physical setup (diameter, tray type, and so forth). • Internal Type (tray type) • Tray Diameter • Tray Space • Tray Volume • Disable Heat Loss Calcs • Heat Model • Rating Calculations • Hold Up (ft3). If you delete the weir height, you can then enter the hold up value, and the weir height is back-calculated. • Weeping Factor. The value is used to adjust the weeping in dynamic mode for low pressure drops. Vessels Provides information regarding vessel sizing. On this page, you can specify the following: • Vessel (Name) • Diameter • Length • Volume • Orientation • Vessel has a Boot • Boot Diameter • Boot Length • Hold Up (ft3) Equipment Contains a list of Other Equipment in the Column flowsheet. Pressure Drop Contains information regarding pressure drop across the column. On this page you can specify the following information: • Pressure Tolerance • Pressure Drop Tolerance • Damping Factor • Maximum Pressure Iterations • Top and Bottom column pressures-87 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -88 Column Property View ww ThTray Sections Page The Tray Sections page contains all the required information for correctly sizing the column tray sections. The tray section diameter, weir length, weir height, and the tray spacing are required for an accurate and stable dynamic simulation. You must specify all the information on this page. With the exception of the tray volume, no other calculations are performed on this page. For multipass trays, simply enter the column diameter and the appropriate total weir length. The required size information for the tray section can be calculated using the Tray Sizing utility. Figure 2.46-88 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -89 ww ThVessels Page The Vessels page contains the necessary sizing information for the different vessels in the column subflowsheet. Equipment Page The Equipment page contains a list of all the additional equipment, which is part of the column subflowsheet. The list does not contain equipment, which is part of the original template. Any extra equipment, which is added to the subflowsheet (pump arounds, side strippers, and so forth) is listed here. Double-clicking on the equipment name opens its property view on the Rating tab. Figure 2.47 This page is not available in the Liquid-Liquid Extractor.-89 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -90 Column Property View ww ThPressure Drop Page The Pressure Drop page allows you to specify the pressure drop across individual trays in the tray section. The pressure at each individual stage can also be specified. The Pressure Solving Options group allows you to adjust the following parameters: • Pressure Tolerance • Pressure Drop Tolerance • Damping Factor • Maximum Pressure Iterations Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the unit operation. The PF Specs page contains a summary of the stream property view’s Dynamics tab. Figure 2.48 This page is not available in the Liquid-Liquid Extractor. Refer to Section 1.3.10 - Worksheet Tab for more information.-90 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -91 ww Th Performance Tab On the Performance tab, you can view the results of a converged column on the Summary page, Column Profiles page, and Feeds/Products page. You can also view the graphical and tabular presentation of the column profile on the Plots page. Summary Page The Summary page gives a tabular summary of the feed and product stream compositions, flows or the % recovery of the components in the product streams. When you select the Recovery radio button, the feed table displays the feed stream flowrate. The Column Environment also has its own Workbook. You can view the results in molar, mass or liquid volume, by selecting the appropriate basis radio button. Figure 2.49-91 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -92 Column Property View ww ThColumn Profiles Page The Column Profiles page gives a tabular summary of Column stage temperatures, pressures, flows, and duties. You can change the basis for which the data appears by selecting the appropriate radio button from the Basis group. Figure 2.50 The liquid and vapour flows are net flows for each stage. The Heat Loss column is empty unless you select a heat flow model in the column subflowsheet of Main TS property view on the Rating tab.-92 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -93 ww ThFeeds/Products Page The Feeds/Products page gives a tabular summary of feed and product streams tray entry/exit, temperatures, pressures, flows, and duties. You can change the basis of the data by selecting the appropriate radio button from the Basis group. For the feeds and draw Streams, the VF column to the right of each flow value indicates whether the flow is vapour (V) or liquid (L). If the feed has been split, a star (*) follows the phase designation. If there is a duty stream on a stage, “Energy” appears in the Type column. The direction of the energy stream is indicated by the sign of the duty. Figure 2.51 You can split a feed stream into its phase components either on the Setup page of the Flowsheet tab in the column property view or on the Options page of the Simulation tab in the Session Preferences property view.-93 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -94 Column Property View ww ThPlots Page On the Plots page, you can view various column profiles or assay curves in a graphical or tabular format. Select the Live Updates checkbox to update the profiles with every pass of the solver (in other words, a dynamic update). This checkbox is cleared by default, because the performance of the column can be a bit slower if the checkbox is selected and a profile is open. Tray by Tray Properties Group To view a column profile, follow this generalized procedure: 1. Select a profile from the list in the Tray by Tray Properties group. The choices include: Temperature, Pressure, Flow, Transport Properties, Composition, K Value, Light/Heavy Key, and Electrolyte Properties. Figure 2.52 Electrolyte Properties are only available for cases with an electrolyte system.-94 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -95 ww Th2. In the Column Tray Ranges group, select the appropriate radio button: 3. After selecting a tray range, click either the View Graph button or the View Table button to display a plot or table respectively. To make changes to the plot, right-click in the plot area, and select Graph Control from the object inspect menu. Radio Button Action All Displays the selected profile for all trays connected to the column (for example, main tray section, side strippers, condenser, reboiler, and so forth). Single Tower From the drop-down list, select a tray section. The main tray section along with the condenser and reboiler are considered one section, as is each side stripper. From/To Use the drop-down lists to specify a specific range of the column. The first field contains the tray that is located at a higher spot in the tower (for example, for top to bottom tray numbering, the first field could be tray 3 and the second tray 6). Figure 2.53 Plots and tables are expandible property views that can remain open without the column property view. Refer to Section 1.3.1 - Graph Control Property View for more information.-95 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -96 Column Property View ww ThDepending on the profile selected, you have to make further specifications. For certain profiles, there is a Properties button on both the profile plot and table. By clicking this button, the Properties property view appears, where you can customize the display of your profile. Changes made on the Properties property view affect both the table and plot. A description of the specifications available for each profile type are outlined in the following table. Profile Type Description Temperature Profile Displays the temperature for the tray range selected. No further specification is needed. Pressure Profile Displays the pressure of each tray in the selected range. No further specification is needed. Flow Profile Displays the flow rate of each tray in the selected range. You can customise the data displayed using the Properties property view. In the Basis group, select molar, mass or liquid volume for your flow profile basis. In the Phase group, select the checkbox for the flow of each phase that you want to display. Multiple flows can be shown. If three phases are not present in the column, the Heavy Liquid checkbox is not available, and thus, the Light Liquid checkbox represents the liquid phase. In the Tray Flow Basis group, you can specify the stage tray flow basis by selecting the appropriate radio button: • Net. The net basis option only includes interstage flow. • Total. The total basis option includes draw and pump around flow.-96 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -97 ww ThTransport Properties Profile Displays the selected properties from each tray in the selected range. You can customise the data displayed using the Properties property view: In the Basis group, select molar or mass for the properties profile basis. In the Phase group, select the checkbox for the flow of each phase that you want to display on the graph. Multiple flows can be shown. If three phases are not present in the column, the Heavy Liquid checkbox is not available. The Properties Profile table displays all of the properties for the phase(s) selected. In the Axis Assignment group, by selecting a radio button under Left, you assign the values of the appropriate property to the left y-axis. To display a second property, choose the radio button under Right. The right y-axis then shows the range of the second property. If you want to display only one property on the plot, select the None radio button under Right. Profile Type Description-97 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -98 Column Property View ww ThComposition Displays the selected component’s mole fraction of each tray in the selected range. You can customise the data displayed using the Properties property view. In the Basis group, select molar, mass or liquid volume for the composition profile basis. In the Phase group, select the checkbox for the flow of each phase that you want to display. Multiple flows can be shown. If the three phases are not present in the column, the Heavy Liquid checkbox is not available, and thus, the Light Liquid checkbox represents the liquid phase. Choose either Fractions or Flows in the Comp Basis group by selecting the appropriate radio button. The Components group displays a list of all the components that enter the tower. You can display the composition profile of any component by selecting the appropriate checkbox. The plot displays any combination of component profiles. K Values Profile Displays the K Values of each tray in the selected range. You can select which components you want included in the profile using the Properties property view. Profile Type Description-98 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -99 ww ThLight/Heavy Key Profile Displays the fraction ratio for each stage. You can customise the data displayed using the Properties property view. In the Basis group, select molar, mass or liquid volume for the profile basis. In the Phase group, select Vapour, Light Liquid or Heavy Liquid for the profile phase. In the Light Key(s) and Heavy Key(s) groups, you can select the key component(s) to include in your profile. Electrolyte Properties Profile Displays the pH and ionic strength or the scale index depending on which radio button you select in the Graph Type group. When you select the pH, Ionic Strength radio button, you can see how the pH value and ionic strength decrease or increase from tray to tray. The Solid Components group displays a list of the solids that could form in the distillation column. You can select or clear the checkboxes to display or hide the scale tendency index value for the solid components in the table or graph. The scale tendency index value refers to its tendency to form at the given tray conditions. Solids with a scale tendency index greater than 1 form, if the solid formation is governed by equilibrium (as oppose to kinetics), and if there are no other solids with a common cation or anion portion which also has scale tendency greater than 1. Profile Type Description-99 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -100 Column Property View ww ThAssay Curves Group From the Assay Curves group, you can create plots and tables for the following properties: • Boiling Point Assay • Molecular Weight Assay • Density Assay • User Properties For each of the options, you can display curves for a single tray or multiple trays. To display a plot or table, make a selection from the list, and click either the View Graph button or the View Table button. The figure below is an example of how a Boiling Point Properties plot appears. Figure 2.54 Figure 2.55-100 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -101 ww ThData Control Property View Click the Profile Data Control button, which is located on bottom left corner of every plot and table, to open the Data Control property view. This property view is common to all plots and tables on the Curves page. For a selected curve, all changes made on the Data Control property view affect the data of both the plot and table. The Data Control property view consists of five groups as shown in the figure below. Figure 2.56-101 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -102 Column Property View ww ThThe following table describes each data control option available according to group name. Group Description Style Select either the Multi Tray or Single Tray radio button. The layout of the Data Control property view differs slightly for each selection. For the Single Tray selection, you must open the drop- down list and select one tray. If you select Multi Tray, the drop-down list is replaced by a list of all the trays in the column. Each tray has a corresponding checkbox, which you can select to display the tray property on the plot or table. Properties Displays the properties available for the plot or table. Each Curve option has its own distinct Properties group. For a single tray selection, you can choose as many of the boiling point curves as required. Select the checkbox for any of the following options: TBP, ASTM D86, D86 Crack Reduced, D1160 Vac, D1160 ATM, and D2887. When multiple trays have been chosen in the Style group, the checkbox list is replaced by a drop-down list. You can only choose one boiling point curve when displaying multiple trays. Basis Select molar, mass or liquid volume for the composition basis. Phase Select the checkbox for the flow of each phase that you want displayed. Multiple flows can be shown. If there are not three phases present in the column, the Heavy Liquid checkbox is not available, and thus, the Light Liquid checkbox represents the liquid phase. Visible Points The radio buttons in the Visible Points group apply to the plots only. Select either the 15 Points or 31 Points option to represent the number of data points which appear for each curve. Refer to Chapter 4 - Aspen HYSYS Oil Manager in the HYSYS Simulation Basis guide for details on boiling point curves.-102 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -103 ww ThTBP Envelope Group The TBP Envelope group contains only the View Graph button. You can click the View Graph button to display a TBP Envelope curve as shown in the figure below. Click the Profile Data Control button located on the property view above to open a property view for customizing your TBP Envelope curve. Figure 2.57 The curve allows you to view product stream distillation overlaid on the column feed distillation. This gives a visual representation of how sharp the separations are for each product. The sharpness of separation is adjusted using section and stripper efficiencies and front and back end shape factors. Figure 2.58 Select a basis to define your TBP profile here. Select from either 100 or 200 data points for your TBP plot. Select either a wet or dry basis. Dry basis is the default selection.-103 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -104 Column Property View ww ThFlowsheet Tab The Flowsheet tab contains the following pages: • Setup • Variables • Internal Streams • Mapping Setup Page The Setup page defines the connections between the internal (subflowsheet) and external (Parent) flowsheets. To split all material inlet streams into their phase components before being fed to the column, select the Split All Inlets checkbox. • If one of the material feed stream Split checkbox is clear, the Split All Inlets checkbox is cleared too. • If you clear the Split All Inlets checkbox, none of the material inlet stream Split checkboxes are affected. The Labels, as noted previously, attach the external flowsheet streams to the internal subflowsheet streams. They also perform the transfer (or translation) of stream information from the property package used in the parent flowsheet into the property package used in the Column subflowsheet (if the two Figure 2.59-104 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -105 ww Thproperty packages are different). The default transfer basis used for material streams is a P-H Flash. The Transfer Basis is significant only when the subflowsheet and parent flowsheet Property Packages are different. When the Split checkbox for any of the inlet material streams is selected, the stream is split into its vapour and liquid phase components. The liquid stream is then fed to the specified tray, and the vapour phase to the tray immediately above the specified feed tray. Energy streams and material streams connected to the top tray (condenser) cannot be split. The checkboxes for there variables appear greyed out. The Flowsheet Topology group provides stage information for each element in the flow sheet. Flash Type Action T-P Flash The pressure and temperature of the material stream are passed between flowsheets. A new vapour fraction is calculated. VF-T Flash The vapor fraction and temperature of the material stream are passed between flowsheets. A new Pressure is calculated. VF-P Flash The vapor fraction and pressure of the material stream are passed between flowsheets. A new temperature is calculated. P-H Flash The pressure and enthalpy of the material stream is passed between flowsheets. This is the default transfer basis. User Specs You can specify the transfer basis for a material Stream. None Required No calculation is required for an energy stream. The heat flow is simply passed between flowsheets. See the Summary page of the Performance tab to verify the split feed streams. An asterisk (*) following the phase indicator in the VF column indicates a split stream. Figure 2.60-105 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -106 Column Property View ww ThFlowsheet Variables Page (Main) The Variables page allows you to select and monitor any flowsheet variables from one location. You can examine subflowsheet variables from the outside Column property view, without actually having to enter the Column subflowsheet environment. You can add, edit or delete variables in the Selected Column flowsheet Variables group. Adding a Variable To add a variable in the Selected Column Flowsheet Variables group: 1. Click the Add button. 2. From the Variable Navigator, select each of the parameters for the variable. 3. Click the OK button. 4. The variable is added to the Selected Column Flowsheet Variables group. Figure 2.61 You can also use the Specifications page to view certain variables. Select the variable by adding a specification, and ensure that the Active and Estimate checkboxes are clear. The value of this variable appears in the Current value column, and this “pseudo-specification” do not affect the solution. Refer to Section 1.3.9 - Variable Navigator Property View for information on the Variable Navigator.-106 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -107 ww ThEditing a Variable You can edit a variable in the Selected Column Flowsheet Variables group as follows: 1. Highlight a variable. 2. Click the Edit button. 3. Make changes to the selections in the Variable Navigator. 4. Click the OK button. If you decide that you do not want to keep the changes made in the variable navigator, click the Cancel button. Deleting a Variable You can remove a variable in any of the following ways: • Select a variable, and click the Delete button. OR • Select a variable, click the Edit button, and then click the Disconnect button on the Variable Navigator. Internal Streams Page On the Internal Streams page, you can create a flowsheet stream that represents any phase leaving any tray within the Column. Streams within operations attached to the main tray section (for example, side strippers, condenser, reboiler, and so forth) can also be targeted. Each time changes occur to the column, new information is automatically transferred to the stream which you have created. Figure 2.62-107 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -108 Column Property View ww ThTo demonstrate the addition of an internal stream, a stream representing the liquid phase flowing from tray 7 to tray 8 in the main tray section of a column is added: 1. Click the Add button. 2. In the Stream drop-down list, type the name of the stream named Liquid. 3. In the Stage drop-down list, select tray 6 or simply type 6, which locates the selection in the list. 4. In the Type drop-down list, select the phase that you want to represent. The options include Vapor, Liquid or Aqueous. Select Liquid in this case. 5. From the Net/Total drop-down list, select either Net or Total. For the stage 6 liquid, select Net. • Net represents the material flowing from the Stage you have selected to the next stage (above for vapour, below for liquid or aqueous) in the column. • Total represents all the material leaving the stage (for example, draws, pump around streams, and so forth). -108 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -109 ww ThMapping Page The Mapping page contains a table that displays the inlet and outlet streams from the column subflowsheet, and component maps for each boundary stream. If the fluid package of the column is the same as the main flowsheet, component maps are not needed (because components are the same on each side of the column boundary). None Req'd is the only option in the drop-down list of the Into Sub-Flowsheet and Out of Sub-Flowsheet columns. If the fluid packages are different, you can choose a map for each boundary stream. HYSYS lists appropriate maps based on the fluid package of each stream across the boundary. Click the Overall Imbalance Into Sub-Flowsheet button or Overall Imbalance Out of Sub-Flowsheet button to view any mole, mass of liquid volume imbalance due to changes in fluid package. If there are no fluid package changes, then there are no imbalances. Figure 2.63 For more detail on the actual map collections and component maps themselves, refer to Chapter 6 - Component Maps in the HYSYS Simulation Basis guide.-109 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -110 Column Property View ww ThReactions Tab Reactive distillation has been used for many years to carry out chemical reactions, in particular esterification reactions. The advantages of using distillation columns for carrying out chemical reactions include: • the possibility of driving the reaction to completion (break down of thermodynamic limitations for a reversible reaction), and separating the products of reactions in only one unit, thus eliminating recycle and reactor costs. • the elimination of possible side reactions by continuous withdrawal of one of the products from the liquid phase. • the operation at higher temperatures (boiling liquid), thus increasing the rate of reaction of endothermic reactions. • the internal recovery of the heat of reaction for exothermic reactions, thereby replacing an equivalent amount of external heat input required for boil-up. The Reactions tab allows you to attach multiple reactions to the column. The tab consists of two pages: • Stages. Allows you select the reaction set, and its scope across the column. • Results. Displays the reaction results stage by stage. This tab is not available for the Liquid-Liquid Extractor. For any column in an electrolyte flowsheet, there is no option to add any reaction (reaction set) to the column. Conceptually, electrolyte thermo conducts a reactive and phase flash all together. HYSYS does not provide options to allow you to add external reactions to the unit operation.-110 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -111 ww ThBefore adding a reaction to a column, you must first ensure that you are using the correct column Solving Method. HYSYS provides three solving methods which allow for reactive distillation. Solving Method Reaction Type Reaction Phase Sparse Continuation Solver Kinetic Rate, Simple Rate, Equilibrium Reaction Vapor, Liquid Newton Raphson Inside-Out Kinetic Rate, Simple Rate Liquid Simultaneous Correction Kinetic Rate, Simple Rate, Equilibrium Reaction Vapor, Liquid, Combined Phase The Sparse Continuation Solver method allows you to attach a reaction set to your column, which combines reaction types. Other solvers require that the attached reactions are of a single type.-111 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -112 Column Property View ww ThStages Page The Stages page consists of the Column Reaction Stages group. The group contains the Column Reaction Stages table and three buttons. Column Reaction Stages Table The table consists of four columns, which are described in the table below. Figure 2.64 Column Description Column Reaction Name The name you have associated with the column reaction. This is not the name of the reaction set you set in the fluid package manager. First Stage The highest stage of the stage range over which the reaction is occurring. Last Stage The lowest stage of the stage range over which the reaction is occurring. Active Activates the associated reaction thereby enabling it to occur inside the column.-112 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -113 ww ThThe property view also contains three buttons that control the addition, manipulation, and deletion of column reactions. Column Reaction Property View The Column Reaction property view allows you to add and revise column reactions. The Column Reaction property view shown in the above figure consists of two groups: • Reaction Set Information The Reaction Set Information group allows you to select the reaction set, and the scope of its application. • Reaction Information The Reaction Information group contains thermodynamic and stoichiometric information about the reaction you are applying to the selected section of the column. Button Description New Allows you to add a new column reaction set via the Column Reaction property view. Edit Allows you to edit the column reaction set whose name is currently selected in Column Reaction Stages table. The selected reaction’s Column Reaction property view appears. Delete Allows you to delete the column reaction set whose name is currently selected in the Column Reaction Stages table. Figure 2.65 For more information of the Column Reaction property view, refer to the section on the Column Reaction Property View.-113 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -114 Column Property View ww ThReaction Set Information Group The Reaction Set Information group consists of six objects: Reaction Information Group The Reaction Information group contains the Reaction field, which allows you to select a reaction from the reaction set selected in the Reaction Set field. Click the View Reaction button to open the selected reaction’s Reaction property view. This group also contains three sub- groups, which allow you to view or specify the selected reactions properties. Objects Description Name The name you would like to associate with the column reaction. This is the name that appears in the Column Reaction Name column of the Column Reaction Stages table. Reaction Set Allows you to select a reaction set from a list of all the reaction sets attached to the fluid package. First Stage The upper limit for the reaction that is to occur over a range of stages. Last Stage The lower limit for the reaction that is to occur over a range of stages. Delete Deletes the Column Reaction from the column. Active Allows you to enable and disable the associated column reaction. Sub-group Description Stoichiometry Allows you to view and make changes to the stoichiometric formula of the reaction currently selected in the Reaction drop-down list. The group contains three columns: • Components. Displays the components involved in the reaction. • Mole Wt. Displays the molar weight of each component involved in the reaction. • Stoich Coeff. Stoichiometric coefficients associated with the reaction.-114 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -115 ww ThResults Page The Results page displays the results of a converged column. Basis Consists of two fields: • Base Component. Displays the reactant to which the reaction extent is calculated. This is often the limiting reactant. • Reaction Phase. Displays the phase for which the kinetic rate equations for different phases can be modeled in the same reactor. To see the possible reactions, click the Reaction Information button in the View Reaction group. You can make changes to the fields in these groups. These changes affect all the unit operations associated with this reaction. Click the View Reactions button for more information about the attached reaction. Heat and Balance Error Consists of two fields: • Reaction Heat. Displays the reaction heat. • Balance Error. Displays any error in the mass balance around the reaction. Figure 2.66 Sub-group Description-115 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -116 Column Property View ww ThThe page consists of a table containing six columns. The columns are described in the following table: If you have more than one reaction occurring at any particular stage, each reaction appears simultaneously. Design Tips for Reactive Distillation 1Although the column unit operations allows for multiple column reactions and numerous column configurations, a general column topography can be subdivided into three sections: • Rectifying Section • Reactive Section • Stripping Section Column Description 1st column Displays the name/number of the column stage. Rxn Name The name of the reaction occurring at this stage. Base Comp The name of the reactant component to which the calculated reaction extent is applied. Rxn Extent The consumption or production of the base component in the reaction. Spec % Conv Displays the percentage of conversion specified by you. Act % Conv Displays the percentage of conversion calculated by HYSYS. The Rxn Extent results appear only if the Sparse Continuation Solver is chosen as the Solving Method.-116 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -117 ww ThWhile the Rectifying and Stripping Sections are similar to ordinary distillation, a reactive distillation column also has a Reactive Section. The Reactive Section of the column is where the main reactions occur. There is no particular requirement for separation in this section. There are several unique operational considerations when designing a reactive distillation column: • The operating pressure should be predicated on the indirect effects of pressure on reaction equilibrium. • The optimum feed point to a reactive distillation column is just below the reactive section. Introducing a feed too far below the reactive section reduces the stripping potential of the column and results in increased energy consumption. • Reflux has a dual purpose in reactive distillation. Increasing the reflux rate enhances separation and recycles unreacted reactants to the reaction zone thereby increasing conversion. • Reboiler Duty is integral to reactive distillation as it must be set to ensure sufficient recycle of unreacted, heavy reactant to the reaction zone without excluding the light reactant from the reaction zone, if the reboiler duty is too high or too low, conversion, and purity can be compromised. Figure 2.67 Strippin g Reactive Section Rectifyin g Section-117 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -118 Column Property View ww ThDynamics Tab The Dynamics tab contains the following pages: • Vessels • Equipment • Holdup If you are working exclusively in Steady State mode or your version of HYSYS does not support dynamics, you are not required to change any information on the pages accessible through this tab. Vessels Page The Vessels page contains a summary of the sizing information for the different vessels contained in the column subflowsheet. In addition, it contains the possible dynamic specifications for these vessels. Figure 2.68-118 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -119 ww ThEquipment Page The Equipment page displays the same information as the Equipment page on the Rating tab. The difference is that double-clicking on the equipment name opens its property view on the Dynamics tab. Holdup Page The Holdup page contains a summary of the dynamic information calculated by HYSYS. Perturb Tab The Perturb tab is only available in the Column Runner property view. The Perturb tab allows you to control the way column solver calculates the partial derivatives. There are two types of independent controls. This page is not available for the Liquid-Liquid Extractor. Column Description Pressure Displays the calculated stage pressure. Total Volume Displays the stage volume. Bulk Liq Volume Displays the liquid volume occupying the stage. Control Description Low Level Analytic The Analytic property derivatives checkbox allows you to turn On and Off low level analytic derivatives support (in other words, derivatives of thermodynamic properties like Fugacity, Enthalpy, and Entropy by Temperature, Pressure, and Composition). At present this facility is available for Peng Robinson or Soave-Redlich-Kwong property packages in Sparse Continuation Solver context. Optimizer Level Analytic HYSYS Optimizer (RTO+) allows calculation of column analytic derivatives by stream Temperature, Pressure, Component Flow, Column Spec specified value, and Tear Variables.-119 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -120 Column Property View ww ThThe Sparse analytic page allows you to select a particular method of column analytic derivatives calculation. The Perturb method parameters group provides tuning parameters for analytic column derivatives calculator. • Rigorous properties checkbox. If active, rigorous thermodynamic properties are applied in Jacobi matrix calculation. If inactive, simple models (controlled by Control panel of Sparse solver) are applied instead for Enthalpy and Fugacity of thermodynamic phases. The last option may expedite derivative calculations. • Warm restart checkbox. If active, additional Sparse linear solver information is preserved between Analytic derivative calculator calls (faster solution of linear system). If inactive, no Sparse linear solver information is stored (memory economy). • Skip Sparse Solve checkbox. If active, Column solution phase is skipped (may allow faster execution). Figure 2.69-120 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -121 ww ThColumn Specification Types This section outlines the various Column specification (spec) types available along with relevant details. Specs are added and modified on the Specs Page or the Monitor Page of the Design tab. Adding and changing Column specifications is straightforward. If you have created a Column based on one of the templates, HYSYS already has default specifications in place. The type of default specification depends on which of the templates you have chosen. Cold Property Specifications Figure 2.70 Cold Property Description Flash Point Allows you to specify the Flash Point temperature (ASTM D93 flash point temperature closed cup) for the liquid or vapour flow on any stage in the column. Pour Point Allows you to specify the ASTM Pour Point temperature for the liquid or vapour flow on any stage in the column. RON Allows you to specify the Research Octane Number for the liquid or vapour flow on any stage. Refer to the Default Replaceable Specifications in Section - Templates for more information.-121 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -122 Column Specification Types ww ThComponent Flow Rate The flow rate (molar, mass or volume) of any component, or the total flow rate for any set of components, can be specified for the flow leaving any stage. If a side liquid or vapour draw is present on the selected stage, these are included with the internal vapour and liquid flows. Component Fractions The mole, mass or volume fraction can be specified in the liquid or vapour phase for any stage. You can specify a value for any individual component, or specify a value for the sum of the mole fractions of multiple components. Component Ratio The ratio (molar, mass or volume fraction) of any set of components over any other set of components can be specified Figure 2.71 Figure 2.72-122 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -123 ww Thfor the liquid or vapour phase on any stage. Component Recovery Component recovery is the molar, mass or volume flow of a component (or group of components) in any internal or product stream draw divided by the flow of that component (or group) in the combined tower feeds. As the recovery is a ratio between two flows, you specify a fractional value. Also, there is no need to specify a Flow Basis since this is a ratio of the same component between specified stream and the combined tower feeds. Cut Point This option allows a cut point temperature to be specified for the liquid or vapour leaving any stage. The types are TBP, ASTM D86, D1160 Vac, D1160 ATM, and ASTM D2887. For D86, you are given the option to use ASTM Cracking Factor. For D1160, you are given an Atmospheric Pressure option. The cut point can be on a mole, mass or volume fraction basis, and any value Figure 2.73 Figure 2.74-123 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -124 Column Specification Types ww Thfrom 0 to 100 percent is allowed. Draw Rate The molar, mass or volume flowrate of any product stream draw can be specified. Delta T (Heater/Cooler) The temperature difference across a Heater or Cooler unit operation can be specified. The Heater/Cooler unit must be installed in the Column subflowsheet, and the HYSIM Inside- Out, Modified HYSIM Inside-Out or Sparse Continuation solving methods must be selected on the Solver page of the Parameters tab. Figure 2.75 While initial and final cut points are permitted, it is often better to use 5 and 95 percent cut points to minimize the errors introduced at the extreme ends of boiling point curves. Figure 2.76-124 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -125 ww ThDelta T (Streams) The temperature difference between two Column subflowsheet streams can be specified. Duty You can specify the duty for an energy stream. Duty Ratio You can specify the duty ratio for any two energy streams. In addition to Column feed duties, the choice of energy streams also includes pump around duties (if available). Feed Ratio The Feed Ratio option allows you to establish a ratio between the flow rate on or from any stage in the column, and the external feed to a stage. You are prompted for the stage, flow Figure 2.77 Figure 2.78 Figure 2.79-125 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -126 Column Specification Types ww Thtype (Vapor, Liquid, Draw), and the external feed stage. Gap Cut Point The Gap Cut Point is defined as the temperature difference between a cut point (Cut Point A) for the liquid or vapour leaving one stage, and a cut point (Cut Point B) on a different stage. You have a choice of specifying the distillation curve to be used: • TBP • ASTM D86 • D1160 Vac • D1160 ATM Figure 2.80 This type of specification is useful for turn down or overflash of a crude feed. Figure 2.81 This specification is best used in combination with at least one flow specification; using this specification with a Temperature specification can produce non-unique solutions.-126 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -127 ww Th• ASTM D2887 You can define Cut Point A and Cut Point B, which together must total 100%. The cut points can be on a mole, mass or volume basis. Liquid Flow The net molar, mass or volume liquid (Light or Heavy) flow can be specified for any stage. Physical Property Specifications The mass density can be specified for the liquid or vapour on any stage. Figure 2.82 Figure 2.83-127 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -128 Column Specification Types ww ThPump Around Specifications Reboil Ratio You can specify the molar, mass or volume ratio of the vapour Figure 2.84 Specification Description Flow Rate The flow rate of the Pump Around can be specified in molar, mass, or liquid volume units. Temperature Drop Allows you to specify the temperature drop across a Pump Around exchanger. The conditions for using this specification are the same as that stated for the Pump Around return temperature. Return Temperature The return temperature of a Pump Around stream can be specified. Ensure that you have not also specified both the pump around rate and the duty. This would result in the three associated variables (flow rate, side exchanger duty, and temperature) all specified, leaving HYSYS with nothing to vary in search of a converged solution. Duty You can specify the duty for any Pump Around. Return Vapor Fraction You can specify the return vapour fraction for any Pump Around. Duty Ratio To specify a Pump Around duty ratio for a Column specification, add a Column Duty Ratio spec instead, and select the Pump Around energy streams to define the duty ratio. The Pump Around Rate, as well as the Pump Around Temperature Drop are the default specifications HYSYS requests when a pump around is added to the column. Refer to Section - Duty Ratio for more information.-128 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -129 ww Thleaving a specific stage to the liquid leaving that stage. Recovery The Recovery spec is the recovery of the total feed flow in the defined outlet streams (value range between 0 and 1). Reflux Feed Ratio The Reflux Feed Ratio spec is the fraction of the reflux flow divided by the reference flow for the specified stage and phase. Figure 2.85 (2.7) Figure 2.86 (2.8) Figure 2.87 molar flow of draw stream total molar feed flow --------------------------------------------------------------- % recovery= reflux flow reference flow ---------------------------------- reflux feed ratio=-129 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -130 Column Specification Types ww ThReflux Fraction Ratio The Reflux Fraction Ratio spec is the fraction or % of liquid that is being refluxed on the specified stage (value range between 0 and 1). Reflux Ratio The Reflux Ratio is the molar, mass or volume flow of liquid (Light or Heavy) leaving a stage, divided by the sum of the vapour flow from the stage plus any side liquid flow. The Reflux Ratio specification is normally used only for top stage condensers, but it can be specified for any stage. For a Partial Condenser: • Selecting the Include Vapour checkbox, gives the following equation for the reflux ratio: • Clearing the Include Vapour checkbox, gives the following equation for the reflux ratio: Figure 2.88 Figure 2.89 Reflux Ratio property view for three phase distillation column Reflux Ratio property view for general column Reflux Ratio R V D+ -------------= Reflux Ratio R D ---=-130 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -131 ww Thwhere: R = liquid reflux to column V = vapor product D = distillate product Tee Split Fraction The split fraction for a Tee operation product stream can be specified. The Tee must be installed within the Column subflowsheet and directly attached to the column, for example, to a draw stream, in a pump around circuit, and so forth. Also, the Modified HYSIM Inside-Out solving method must be selected. Tee split fraction specifications are automatically installed as you install the tee operation in the Column subflowsheet; however, you can select which specifications become active on the Monitor page or Specs page. Changes made to the split fraction specification value are updated on the Splits page of the tee operation. Tray Temperature The temperature of any stage can be specified. Transport Property Specifications The viscosity, surface tension or thermal conductivity can be specified for the liquid leaving any stage. The viscosity or thermal conductivity can be specified for the vapour leaving any Figure 2.90 Refer to Section 6.6 - Tee for details on the Tee operation.-131 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -132 Column Specification Types ww Thstage. A reference temperature must also be given. User Property A User Property value can be specified for the flow leaving any stage. You can choose any installed user property in the flowsheet, and specify its value. The basis used in the installation of the user property is used in the spec calculations. Vapor Flow The net molar, mass or volume vapor flow can be specified for any stage. Feeds and draws to that tray are taken into account. The computing time required to satisfy a vapour viscosity specification can be considerably longer than that needed to meet a liquid viscosity specification. Figure 2.91 Figure 2.92 Figure 2.93-132 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -133 ww ThVapor Fraction The vapour fraction of a stream exiting a stage can be specified. Vapor Pressure Specifications Two types of vapour pressure specifications are available: • true vapour pressure (@100°F) • Reid vapour pressure. Column Stream Specifications Column stream specifications must be created in the Column subflowsheet. Unlike other specifications, the stream specification is created through the stream’s property view, and not the Column Runner Specs page. To be able to add a specification to a stream: Figure 2.94 Figure 2.95 Vapor Type Description Vapor Pressure The true vapour pressure at 100°F can be specified for the vapour or liquid leaving any stage. Reid Vapor Pressure Reid vapour pressure can be specified for the vapour or liquid leaving any stage. The specification must always be given in absolute pressure units.-133 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -134 Column Stream Specifications ww Th• The Modified HYSIM Inside-out solving method must be chosen for the solver. • The stream must be a draw stream. The Create Column Stream Spec button on the Conditions page of the Worksheet tab is available only on Stream property views within the Column subflowsheet. When you click on the Create Column Stream Spec button, the Stream Spec property view appears. • For draw streams from a separation stage (tray section stage, condenser or reboiler) only a stream temperature specification can be set. • For a non-separation stage streams (from pumps, heaters, and so forth) either a temperature or a vapour fraction specification can be set. • For any given stage, only one draw stream specification can be active at any given time. Once a specification is added for a stream, the button on the Conditions page of the Worksheet tab changes from Create Column Stream Spec to View Column Stream Spec, and can be clicked to view the Stream Specification property view. Only one stream specification can be created per draw stream. Figure 2.96 Creating a new stream specification for a stage, or activating a specification automatically deactivates all other existing draw stream specifications for that stage. You can only add Column Stream Specifications via the Stream property view of a draw stream within the Column subflowsheet.-134 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -135 ww ThColumn-Specific Operations The procedure for installing unit operations in a Column subflowsheet is the same as in the main flowsheet. The UnitOps property view for the Column appears by selecting the Flowsheet | Add Operation command from the menu bar, or by pressing F12. The unit operations available within the Column subflowsheet are listed in the following table. Most operations shown here are identical to those available in the main flowsheet in terms of specified and calculated Figure 2.97 Operation Category Types Vessels 3-Phase Condenser, Partial Condenser, Reboiler, Separator, Total Condenser, Tray Section Heat Transfer Equipment Cooler, Heater, Heat Exchanger Rotating Equipment Pump Piping Equipment Valve Logicals Balance, Digital Pt, PID Controller, Selector Block, Transfer Function Block Refer to Section 1.2.1 - Installing Operations for more information.-135 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -136 Column-Specific Operations ww Thinformation, property view structure, and so forth. There are also additional unit operations which are not available in the main flowsheet. They are: • Condenser (Partial, Total, 3-Phase) • Reboiler • Tray Section The Bypasses and Side Operations (side strippers, pump arounds, and so forth) are available on the Side Ops page of the Column property view. Condenser The Condenser is used to condense vapour by removing its latent heat with a coolant. In HYSYS, the condenser is used only in the Column Environment, and is generally associated with a Column Tray Section. There are four types of Condensers: Only the operations which are applicable to a Column operations are available within the Column subflowsheet. You can open a property view of the Column PFD from the main build environment. This PFD only provides you with the ability to modify stream and operation parameters. You cannot add and delete operations or break stream connections. These tasks can only be performed in the Column subflowsheet environment. Condenser Type Description Partial Feed is partially condensed; there are vapour and liquid product streams. The Partial Condenser can be operated as a total condenser by specifying the vapour stream to have zero flowrate. The Partial Condenser can be used as a Total Condenser simply by specifying the vapour flowrate to be zero. Total Feed is completely condensed; there is a liquid product only. Refer to Section 7.24.4 - Access Column or Subflowsheet PFDs in the HYSYS User Guide for more information-136 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -137 ww ThWhen you add a Column to the simulation using a pre-defined template, there can be a condenser attached to the tower (for example, in the case of a Distillation Column). To manually add a Condenser do one of the following: • In the Column environment, press F12 and make the appropriate selection from the UnitOps property view. • In the Column environment, press F4 and click a Condenser icon from the Column Palette. The Condenser property view uses a Type drop-down list, which allows you to switch between condenser types without having to delete and re-install a new piece of equipment. When you switch between the condenser types, the pages change appropriately. For example, the Connections page for the Total Condenser does not show the vapor stream. If you Three-Phase - Chemical There are two liquid product streams and one vapour product stream. Three-Phase - Hydrocarbon There is a liquid product streams and a water product stream and one vapour product stream. Figure 2.98 Condenser Type Description Partial Condenser icon Total Condenser icon Three-Phase Condenser icon-137 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -138 Column-Specific Operations ww Thswitch from the Partial to Total Condenser, the vapor stream is disconnected. If you then switch back, you have to reconnect the stream. The Condenser property view has the same basic five tabs that are available on any unit operation: • Design • Rating • Worksheet • Performance • Dynamics It is necessary to specify the connections and the parameters for the Condenser. The information on the Dynamics tab are not relevant in steady state. Design Tab The Design tab contains options to configure the Condenser. Connections Page On the Connections page, you can specify the operation name, as well as the feed(s), vapour, water, reflux, product, and energy streams. Figure 2.99-138 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -139 ww ThThe Connections page shows only the product streams, which are appropriate for the selected condenser. For example, the Total Condenser does not have a vapour stream, as the entire feed is liquefied. Neither the Partial nor the Total Condenser has a water stream. The Condenser is typically used with a tray section, where the vapour from the top tray of the column is the feed to the condenser, and the reflux from the condenser is returned to the top tray of the column. Parameters Page The condenser parameters that can be specified are: • Pressure Drop • Duty • Subcooling Data Figure 2.100 It is better to use a duty spec than specifying the heat flow of the duty stream.-139 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -140 Column-Specific Operations ww ThPressure Drop The Pressure Drop across the condenser (Delta P) is zero by default. It is defined in the following expression: where: P = vessel pressure Pv = pressure of vapour product stream Pl = pressure of liquid product stream Pfeed = pressure of feed stream to condenser = pressure drop in vessel (Delta P) Duty The Duty for the energy stream can be specified here, but this is better done as a column spec (defined on the Monitor page or Specs page of the Column property view). This allows for more flexibility when adjusting specifications, and also introduces a tolerance. The Duty should be positive, indicating that energy is being removed from the Condenser feed. The steady state condenser energy balance is defined as: (2.9) You typically specify a pressure for the condenser during the column setup, in which case the pressure of the top stage is the calculated value. If you specify the duty, it is equivalent to installing a duty spec, and a degree of freedom is used. Hfeed - Duty = Hvapour + Hliquid (2.10) P Pv Pl Pfeed ΔP–= = = ΔP-140 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -141 ww Thwhere: Hfeed = heat flow of the feed stream to the condenser Hvapour = heat flow of the vapour product stream Hliquid = heat flow of the liquid product stream(s) SubCooling In some instances, you want to specify Condenser SubCooling. In this situation, either the Degrees of SubCooling or the SubCooled Temperature can be specified. If one of these fields is set, the other is calculated automatically. Estimate Page On the Estimate page you can estimate the flows and phase compositions of the streams exiting the Condenser. You can enter any value for fractional compositions, and click the Normalize Composition button to have HYSYS normalize the values such that the total equals 1. This button is useful when In steady state, SubCooling applies only to the Total Condenser. There is no SubCooling in dynamics. Figure 2.101-141 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -142 Column-Specific Operations ww Thmany components are available, but you want to specify compositions for only a few. HYSYS also specifies any compositions as zero. HYSYS re-calculates the phase composition estimates when you click the Update Comp. Est. button. Clicking this button also removes any of the estimated values you entered for the phase composition estimates. Click the Clear Comp. Est. button to clear the phase compositions estimated by HYSYS. This button does not remove any estimate values you entered. You can clear the all estimate values by clicking the Clear All Comp. Est. button. -142 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -143 ww ThUser Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. Rating Tab The Rating tab contains options that are applicable in both Steady State and Dynamics mode. Sizing Page The Sizing page contains all the required information for correctly sizing the condenser. You can select either vertical or horizontal orientation, and cylinder or sphere. You can either enter the volume or Figure 2.102 For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.-143 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -144 Column-Specific Operations ww Thdimensions for your condenser. You can also indicate whether or not the condenser has a boot associated with it. If it does, then you can specify the boot dimensions. Nozzles Page The Nozzles page contains information regarding the elevation and diameter of the nozzles. The information provided in the Nozzles page is applicable only in Dynamic mode. Figure 2.103 Refer to Section 1.3.6 - Nozzles Page for more information.-144 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -145 ww ThHeat Loss Page The Heat Loss page allows you to specify the heat loss from individual trays in the tray section. You can choose either a Direct Q, Simple, or Detailed heat loss model or no heat loss from the Heat Loss Mode group. Direct Q Heat Loss Model The Direct Q model allows you to either specify the heat loss directly, or have the heat loss calculated from the Heat Flow for the condenser. Figure 2.104 Figure 2.105-145 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -146 Column-Specific Operations ww ThSimple Heat Loss Model The Simple model allows you to calculate the heat loss from these specified values: • Overall U value • Ambient Temperature Detailed Heat Loss Model The Detailed model allows you to specify more detailed heat transfer parameters. Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the Condenser. Figure 2.106 Figure 2.107 The PF Specs page is relevant to dynamics cases only. Refer to Section 1.6.1 - Detailed Heat Model in the HYSYS Dynamic Modeling guide for more information. Refer to Section 1.3.10 - Worksheet Tab for more information.-146 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -147 ww ThPerformance Tab The Performance tab has the following pages: • Plots • Tables • SetUp From these pages you can select the type of variables you want to calculate and plot, view the calculated values, and plot any combination of the selected variables. The default selected variables are temperature, pressure, heat flow, enthalpy, and vapor fraction. At the bottom of the Plots or Tables page, you can specify the interval size over which the values should be calculated and plotted. Figure 2.108 In steady state, the displayed plots are all straight lines. Only in Dynamic mode, when the concept of zones is applicable, do the plots show variance across the vessels.-147 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -148 Column-Specific Operations ww ThDynamics Tab The Dynamics tab contains the following pages: • Specs • Holdup • StripChart • Heat Exchanger You are not required to modify information on the Dynamics tab when working in Steady State mode. Specs Page The Specs page contains information regarding initialization modes, condenser geometry, and condenser dynamic specifications. Figure 2.109-148 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -149 ww ThModel Details In the Model Details group, you can specify the initial composition and amount of liquid that the separator should start with when you start dynamics. This is done via the initialization mode which is discussed in the table below. The condenser geometry can be specified in the Model Details group. The following condenser geometry parameters can be specified in the same manner as the Geometry group on Sizing page of the Rating tab: • Volume • Diameter • Height (Length) • Geometry (Level Calculator) The Liquid Volume Percent value is also displayed in this group. You can modify the level in the condenser at any time. HYSYS then uses that level as an initial value when the integrator is run. The Fraction Calculator determines how the level in the condenser and the elevation and diameter of the nozzle affects the product composition. There is only one Fraction Calculation Initialization Mode Description Initialize from Products The composition of the holdup is calculated from a weighted average of all products exiting the holdup. A PT flash is performed to determine other holdup conditions. The liquid level is set to the value indicated in the Liq Volume Percent field. Dry Startup The composition of the holdup is calculated from a weighted average of all feeds entering the holdup. A PT flash is performed to determine other holdup conditions. The liquid level in the Liq Volume Percent field is set to zero. Initialize from User The composition of the liquid holdup in the condenser is user specified. The molar composition of the liquid holdup can be specified by clicking the Init Holdup button. The liquid level is set to the value indicated in the Liq Volume Percent field. The Initialization Mode can be changed any time when the integrator is not running. The changes cause the vessel to re-initialize when the integrator is started again. Refer to the section on the Nozzles Page for more details.-149 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -150 Column-Specific Operations ww Thmode available, it is called Use Levels and Nozzles. The calculations are based on how the nozzle location and vessel liquid level affect the product composition. Dynamic Specifications The Dynamic Specifications group contains fields, where you can specify what happens to the pressure and reflux ratio of the condenser when you enter dynamic mode. The Fixed Pressure Delta P field allows you to impose a fixed pressure drop between the vessel and all of the feed streams. This is mostly supported for compatibility with Steady State mode. In Dynamic mode, you are advised to properly account for all pressure losses by using the appropriate equipment such as valves or pumps or static head contributions. A zero pressure drop should preferably be used here otherwise you may get unrealistic results such as material flowing from a low to a high pressure area. The Fixed Vessel Pressure field allows you to fix the vessel pressure in Dynamic mode. This option can be used in simpler models where you do not want to configure pressure controllers and others, or if the vessel is open to the atmosphere. In general the specification should not be used, because the pressure should be determined by the surrounding equipment. The Reflux Flow/Total Liquid Flow field provides you with a simple reflux ratio control option, and the ratio determines the reflux flow rate divided by the sum of the reflux and distillate flow rates. The Add/Configure Level Controller button installs a level controller on the distillate (liquid) outlet stream if one is not already present. If this stream has a valve immediately This option allows you to set up simple models without having to add the valves, pumps, and controller that would normally be present. This option does not always give desirable results under all conditions such as very low levels or reversal of some of the streams.-150 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -151 ww Thdownstream of the vessel, the controller is configured to control the valve rather than the stream directly. In any case, the controller is configured with some basic tuning parameters, but you can adjust those. The default tuning values are as follows: • Kp = 1.8 • Ti = 4 * Residence time / Kp Holdup Page The Holdup page contains information regarding the properties, composition, and amount of the holdup. The Levels group displays the following variables for each of the phases available in the vessel: • Level. Height location of the phase in the vessel. • Percent Level. Percentage value location of the phase in the vessel. • Volume. Amount of space occupied by the phase in the vessel. Figure 2.110 Refer to Section 1.3.3 - Holdup Page for more information.-151 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -152 Column-Specific Operations ww ThStripChart Page The Stripchart page allows you to select and create default strip charts containing various variable associated to the operation. Heat Exchanger Page The Heat Exchanger page opens a list of available heating methods for the unit operation. This page contains different objects depending on which configuration you select. • If you select the None radio button, this page is blank and the Condenser has no cooling source. • If you select the Duty radio button, this page contains the standard cooling parameters and you have to specify an energy stream for the Condenser. • If you select the Tube Bundle radio button, this page contains the parameters used to configure a kettle chiller and you have to specify the required material streams for the kettle chiller. Figure 2.111 Refer to Section 1.3.7 - Stripchart Page/Tab for more information. Refer to Duty Radio Button for more information. Refer to Tube Bundle Radio Button for more information.-152 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -153 ww ThDuty Radio Button When the Duty radio button is selected the following heat transfer options are available. The Heater Type group has two radio buttons: • Gas Heater. When you select this radio button, the duty is linearly reduced so that it is zero at liquid percent level of 100%, unchanged at liquid percent level of 50%, and doubled at liquid percent level of 0%. The following equation is used: where: Q = total heat applied to the holdup L= liquid percent level QTotal = duty calculated from the duty source The heat applied to the Condenser operation directly varies with the surface area of vapour contacting the vessel wall. The Tube Bundle options are only available in Dynamics mode. If you switch from Duty option or Tube Bundle option to None option, HYSYS automatically disconnects the energy or material streams associated to the Duty or Tube Bundle options. Figure 2.112 (2.11)Q 2 0.02L–( )QTotal=-153 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -154 Column-Specific Operations ww Th • Vessel Heater. When you select this radio button, 100% of the duty specified or calculated in the SP cell is applied to the vessel’s holdup. That is: where: Q = total heat applied to the holdup QTotal = duty calculated from the duty source The Duty Source group has two radio buttons: • Direct Q • From Utility Figure 2.113 The Gas Heater method is available only for condensers, because the heat transfer in the Condenser depends more on the surface area of the vapour contacting the cooling coils than the liquid. Q = QTotal (2.12) The Vessel Heater method is a non-scaling method. 0 20 40 60 80 100 0 40 80 120 160 200 Liquid Percent Level, L Pe rc en t o f H ea t A p p lie d Percent Heat Applied to Condenser-154 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -155 ww ThWhen you select the Direct Q radio button, the Direct Q Data group appears. The following table describes the purpose of each object in the group. When you select the From Utility radio button, the Utility Flow Properties group appears. The following table describes the purpose of each object that appears when the From Utility radio button is selected. Object Description SP The heat flow value in this cell is the same value specified in the Duty field on the Parameters page of the Design tab. Any changes made in this cell are reflected on the Duty field on the Parameters page of the Design tab. Min. Available Allows you to specify the minimum amount of heat flow. Max. Available Allows you to specify the maximum amount of heat flow. Figure 2.114 Object Description Heat Flow Displays the heat flow value. UA Displays the overall heat transfer coefficient. Holdup Displays the amount of holdup fluid in the condenser. Flow Displays the amount of fluid flowing out of the condenser. Min. Flow Displays the minimum amount of fluid flowing out of the condenser. Max. Flow Displays the maximum amount of fluid flowing out of the condenser. Heat Capacity Displays the heat capacity of the fluid. The cells containing: • black text indicates the value is calculated by HYSYS and cannot be changed. • blue text indicates the value is entered by you, and you can change the value. • red text indicates the value is calculated by HYSYS, and you can change the value.-155 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -156 Column-Specific Operations ww ThReboiler If you choose a Reboiled Absorber or Distillation template, it includes a Reboiler which is connected to the bottom tray in the tray section with the streams to reboiler and boilup. The Reboiler is a column operation, where the liquid from the bottom tray of the column is the feed to the reboiler, and the boilup from the reboiler is returned to the bottom tray of the column. The Reboiler is used to partially or completely vapourize liquid feed streams. You must be in a Column subflowsheet to install the Reboiler. Inlet Temp. Displays the temperature of the stream flowing into the condenser. Outlet Temp. Displays the temperature of the stream flowing out of the condenser. Temp Approach Displays the value of the operation outlet temperature minus the outlet temperature of the Utility Fluid. It is only used when one initializes the duty valve via the Initialize Duty Valve button. Initialize Duty Valve Allows you to initialize the UA, flow, and outlet temperature to be consistent with the duty for purposes of control. Figure 2.115 Object Description-156 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -157 ww ThTo install the Reboiler operation do one of the following: • In the Column environment, press F12 and select Reboiler from the UnitOps property view. • In the Column environment, press F4 and click the Reboiler icon in the Column Palette. The Reboiler property view has the same basic tabs that are available on any unit operation: • Design • Rating • Worksheet • Performance • Dynamics It is necessary to specify the connections, and the parameters for the Reboiler. The information on the Dynamics tab are not relevant in steady state. Design Tab The Design tab contains the following pages: • Connections • Parameters • User Variables • Notes Reboiler icon-157 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -158 Column-Specific Operations ww ThConnections Page On the Connections page, you must specify the Reboiler name, as well as the feed(s), boilup, vapor draw, energy, and bottoms product streams. The vapor draw stream is optional. Parameters Page On the Parameter page, you can specify the pressure drop and energy used by the Reboiler. The pressure drop across the Reboiler is zero by default. The Duty for the energy Stream should be positive, indicating that energy is being added to the Reboiler feed(s). If you specify the duty, a degree of freedom is used. Figure 2.116 Figure 2.117-158 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -159 ww ThThe steady state reboiler energy balance is defined as: where: Hfeed = heat flow of the feed stream to the reboiler Hvapour = heat flow of the vapour draw stream Hbottoms = heat flow of the bottoms product stream Hboilup = heat flow of the boilup stream User Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. Rating Tab The Rating tab contains the following pages: • Sizing • Nozzles • Heat Loss It is recommended to define a duty specification on the Monitor page or Specs page of the Column property view, instead of specifying a value for the duty stream. Hfeed + Duty = Hvapour + Hbottom + Hboilup (2.13) Rating tab for a Reboiler is the same as the Rating tab for the Condenser. For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.-159 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -160 Column-Specific Operations ww ThSizing Page The Sizing page contains all the required information for correctly sizing the reboiler. You can select either vertical or horizontal orientation, and cylinder or sphere. You can either enter the volume or dimensions for your reboiler. You can also indicate whether or not the reboiler has a boot associated with it. If it does, you can specify the boot dimensions. Nozzles Page The Nozzles page contains information regarding the elevation and diameter of the nozzles. The information provided in the Nozzles page is applicable only in Dynamic mode. Heat Loss Page The Heat Loss page allows you to specify the heat loss from Figure 2.118 Figure 2.119 Refer to Section 1.3.6 - Nozzles Page for more information.-160 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -161 ww Thindividual trays in the tray section. You can choose either a Direct Q, Simple or Detailed heat loss model or no heat loss from the Heat Loss Mode group. Direct Q Heat Loss Model The Direct Q model allows you to either specify the heat loss directly, or have the heat loss calculated from the Heat Flow for the reboiler. Simple Heat Loss Model The Simple model allows you to calculate the heat loss from these specified values: • Overall U value • Ambient Temperature Detailed Heat Loss Model The Detailed model allows you to specify more detailed heat Figure 2.120 Figure 2.121 Refer to Section 1.6.1 - Detailed Heat Model in the HYSYS Dynamic Modeling guide for more information.-161 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -162 Column-Specific Operations ww Thtransfer parameters. Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the Reboiler. Performance Tab The Performance tab of the Reboiler has the same pages as the Performance tab of the Condenser: • Plots • Tables Figure 2.122 The PF Specs page is relevant to dynamics cases only. Refer to Section 1.3.10 - Worksheet Tab for more information.-162 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -163 ww Th• SetUp From these pages you can select the type of variables you want to calculate and plot, view the calculated values, and plot any combination of the selected variables. The default selected variables are temperature, pressure, heat flow, enthalpy, and vapor fraction. At the bottom of the Plots or Tables page, you can specify the interval size over which the values should be calculated and plotted. Dynamics Tab The Dynamics tab contains the following pages: • Specs • Holdup • StripChart • Heat Exchanger Figure 2.123 The Dynamics tab for a Reboiler is the same as the Dynamics tab for the Condenser. You are not required to modify information on the Reboiler’s Dynamics tab when working in Steady State mode.-163 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -164 Column-Specific Operations ww ThSpecs Page The Specs page contains information regarding initialization modes, reboiler geometry, and reboiler dynamic specifications. Model Details In the Model Details group, you can specify the initial composition and amount of liquid that the separator should start with when you start dynamics. This done via the initialization mode which is discussed in the table below. Figure 2.124 Initialization Mode Description Initialize from Products The composition of the holdup is calculated from a weighted average of all products exiting the holdup. A PT flash is performed to determine other holdup conditions. The liquid level is set to the value indicated in the Liq Volume Percent field. Dry Startup The composition of the holdup is calculated from a weighted average of all feeds entering the holdup. A PT flash is performed to determine other holdup conditions. The liquid level in the Liq Volume Percent field is set to zero. Initialize from User The composition of the liquid holdup in the reboiler is user specified. The molar composition of the liquid holdup can be specified by clicking the Init Holdup button. The liquid level is set to the value indicated in the Liq Volume Percent field.-164 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -165 ww ThThe reboiler geometry can be specified in the Model Details group. The following reboiler geometry parameters can be specified in the same manner as the Geometry group on the Sizing page of the Rating tab: • Volume • Diameter • Height (Length) • Geometry (Level Calculator) The Liquid Volume Percent value is also displayed in this group. You can modify the level in the condenser at any time. HYSYS then uses that level as an initial value when the integrator is run. The Fraction Calculator determines how the level in the condenser, and the elevation and diameter of the nozzle affects the product composition. There is only one Fraction Calculation mode available, it is called Use Levels and Nozzles. The calculations are based on how the nozzle location and vessel liquid level affect the product composition. Dynamic Specifications The Dynamic Specifications group contains fields where you can specify what happens to the pressure of the reboiler when you enter dynamic mode. The Feed Delta P field allows you to impose a fixed pressure drop between the vessel and all of the feed streams. This is mostly supported for compatibility with Steady State mode. In Dynamic mode, you are advised to properly account for all pressure losses by using the appropriate equipment such as valves or pumps or static head contributions. A zero pressure drop should preferably be used here otherwise you may get unrealistic results such as material flowing from a low to a high pressure area. The Initialization Mode can be changed any time when the integrator is not running. The changes cause the vessel to re-initialize when the integrator is started again. Refer to the section on the Nozzles Page for more information.-165 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -166 Column-Specific Operations ww ThThe Fixed Vessel Pressure field allows you to fix the vessel pressure in Dynamic mode. This option can be used in simpler models where you do not want to configure pressure controllers and others, or if the vessel is open to the atmosphere. In general the specification should not be used, because the pressure should be determined by the surrounding equipment. Holdup Page The Holdup page contains information regarding the properties, composition, and amount of the holdup. The Levels group displays the following variables for each of the phases available in the vessel: • Level. Height location of the phase in the vessel. • Percent Level. Percentage value location of the phase in the vessel. • Volume. Amount of space occupied by the phase in the vessel. StripChart Page The Stripchart page allows you to select and create default strip charts containing various variable associated to the operation. Figure 2.125 Refer to Section 1.3.3 - Holdup Page for more information. Refer to Section 1.3.7 - Stripchart Page/Tab for more information.-166 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -167 ww ThHeat Exchanger Page The Heat Exchanger page opens a list of available heating methods for the unit operation. This page contains different objects depending on which radio button you select. • If you select the None radio button, this page is blank and the Condenser has no cooling source. • If you select the Duty radio button, this page contains the standard heating parameters and you have to specify an energy stream for the Reboiler. • If you select the Tube Bundle radio button, this page contains the parameters used to configure a kettle reboiler and you have to specify the required material streams for the kettle reboiler. Figure 2.126 The Tube Bundle options are only available in Dynamics mode. If you switch from Duty option or Tube Bundle option to None option, HYSYS automatically disconnects the energy or material streams associated to the Duty or Tube Bundle options. Refer to Duty Radio Button for more information. Refer to Tube Bundle Radio Button for more information.-167 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -168 Column-Specific Operations ww ThDuty Radio Button When the Duty radio button is selected the following heat transfer options are available. The Heater Type group has two radio buttons: • Liquid Heater • Vessel Heater For the Liquid Heater method, the duty applied to the vessel depends on the liquid level in the tank. The heater height value must be specified. The heater height is expressed as a percentage of the liquid level in the vessel operation. The default values are 5% for the top of the heater, and 0% for the bottom of the heater. These values are used to scale the amount of duty that is applied to the vessel contents. Figure 2.127 When you select the Liquid Heater radio button, the Heater Height as % Vessel Volume group appears. This group contains two cells: • Top of Heater • Bottom of Heater These cells are used to specify the heater height. (2.14) Q 0 L B<( ) Q L B– T B– ------------QTotal B L T≤ ≤( ) Q QTotal L T>( ) = = = -168 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -169 ww Thwhere: L = liquid percent level (%) T = top of heater (%) B = bottom of heater (%) The Percent Heat Applied may be calculated as follows: It is shown that the percent of heat applied to the vessel’s holdup directly varies with the surface area of liquid contacting the heater. When you select the Vessel Heater radio button, 100% of the duty specified or calculated in the SP cell is applied to the vessel’s holdup: where: Q = total heat applied to the holdup (2.15) Figure 2.128 Q = QTotal (2.16) Percent Heat Applied Q QTotal --------------- 100%×= 0 20 40 60 80 100 0 20 40 60 80 100 Liquid Percent Level, L Pe rc en t o f H ea t A p p lie d Percent Heat Applied for a Liquid Heater B T-169 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -170 Column-Specific Operations ww ThQTotal = duty calculated from the duty source The Duty Source group has two radio buttons: • Direct Q • From Utility When you select the Direct Q radio button, the Direct Q Data group appears. The following table describes the purpose of each object in the group. When you select the From Utility radio button, the Utility Flow Properties group appears. Object Description SP The heat flow value in this cell is the same value specified in the Duty field of the Parameters page on the Design tab. Any changes made in this cell is reflected on the Duty field of the Parameters page on the Design tab. Min. Available Allows you to specify the minimum amount of heat flow. Max. Available Allows you to specify the maximum amount of heat flow. Figure 2.129 The cells containing: • black text indicates the value is calculated by HYSYS and cannot be changed. • blue text indicates the value is entered by you, and you can change the value. • red text indicates the value is calculated by HYSYS, and you can change the value.-170 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -171 ww ThThe following table describes the purpose of each object that appears when the From Utility radio button is selected. Tray Section At the very minimum, every Column Templates includes a tray section. An individual tray has a vapour feed from the tray below, a liquid feed from the tray above, and any additional feed, draw or duty streams to or from that particular tray. The property view for the tray section of a Distillation Column Object Description Heat Flow Displays the heat flow value. Available UA Displays the overall heat transfer coefficient. Utility Holdup Displays the amount of holdup fluid in the reboiler. Mole Flow Displays the amount of fluid flowing out of the reboiler. Min Mole Flow Displays the minimum amount of fluid flowing out of the reboiler. Max Mole Flow Displays the maximum amount of fluid flowing out of the reboiler. Heat Capacity Displays the heat capacity of the fluid. Inlet Temp. Displays the temperature of the stream flowing into the condenser. Outlet Temp. Displays the temperature of the stream flowing out of the condenser. Initialize Duty Valve Allows you to initialize the UA, flow, and outlet temperature to be consistent with the duty for purposes of control.-171 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -172 Column-Specific Operations ww Thtemplate is shown in the figure below. The tray section property view contains the five tabs that are common to most unit operations: • Design • Rating • Worksheet • Performance • Dynamics You are not required to change anything on the Rating tab and Dynamics tab, if you are operating in Steady State mode. Figure 2.130-172 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -173 ww ThDesign Tab The Design tab contains the following pages: • Connections • Side Draws • Parameters • Pressures • User Variables • Notes Connections Page The Connections page of the Tray Section is used for specifying the names and locations of vapour and liquid inlet and outlet streams, feed streams, and the number of stages (see Figure 2.130). When a Column template is selected, HYSYS inserts the default stream names associated with the template into the appropriate input cells. For example, in a Distillation Column, the Tray Section vapour outlet stream is To Condenser and the Liquid inlet stream is Reflux. A number of conventions exist for the naming and locating of streams associated with a Column Tray Section: • When you select a Tray Section feed stream, HYSYS by default feeds the stream to the middle tray of the column (for example, in a 20-tray column, the feed would enter on tray 10). The location can be changed by selecting the desired feed tray from the drop-down list, or by typing the tray number in the appropriate field. • Streams entering and leaving the top and bottom trays are always placed in the Liquid or Vapor Inlet/Outlet fields.-173 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -174 Column-Specific Operations ww Th Side Draws Page On the Side Draws page, you can specify the name and type of side draws taken from the tray section of your column. Use the radio buttons to select the type of side draw: • Vapor • Liquid • Water Select the cells to name the side draw stream, and specify the tray from which it is taken. Parameters Page You can input the number of trays on the Parameters page. Specifying the location of a column feed stream to be either the top tray (tray 1 or tray N, depending on your selected numbering convention) or the bottom tray (N or 1) automatically results in the stream becoming the Liquid Inlet or the Vapour Inlet, respectively. If the Liquid Inlet or Vapour Inlet already exists, your specified feed stream is an additional stream entering on the top or bottom tray, displayed with the tray number (1 or N). A similar convention exists for the top and bottom tray outlet streams (Vapour Outlet and Liquid Outlet). Figure 2.131-174 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -175 ww ThThe trays are treated as ideal if the fractional efficiencies are set to 1. If the efficiency of a particular tray is less than 1, the tray is modeled using a modified Murphree Efficiency. You can add or delete trays anywhere in the column by clicking the Customize button, and entering the appropriate information in the Custom Modify Number of Trays group. This feature makes adding and removing trays simple, especially if you have a complex column, and you do not want to lose any feed or product stream information. The figure below shows the property view that appears when the Customize button is clicked. You can add and remove trays by: • Specify a new number of trays in the Current Number of Trays field. This is the same as changing the number of theoretical trays on the Connections page. All inlet and outlet streams move appropriately; for example, if you are changing the number of trays from 10 to 20, a stream initially connected to tray 5 is now at tray 10, and a stream initially connected at stream 10 is now at tray 20. • Add or remove trays into or from individual tray section. By default, the Use Tray Section Name for Stage Name checkbox is selected. Figure 2.132 When you are adding or deleting trays, all Feeds remain connected to their current trays.-175 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -176 Column-Specific Operations ww ThAdding Trays To add trays to the tray section: 1. Enter the number of trays you want to add in the Number of Trays to Add/Delete field. 2. Specify the tray number after, which you want to add the trays in the Tray to Add After or Delete First field. 3. Click the Add Trays button, and HYSYS inserts the trays in the appropriate place according to the tray numbering sequence you are using. All streams (except feeds) and auxiliary equipment below (or above, depending on the tray numbering scheme) the tray where you inserted is moved down (or up) by the number of trays that were inserted. Removing Trays To remove trays from the tray section: 1. Enter the number of trays you want to delete in the Number of Trays to Add/Delete field. 2. Enter the first tray in the section you want to delete in the Tray to Add After or Delete First field. 3. Click the Remove Trays button. All trays in the selected section are deleted. If you are using the top-down numbering scheme, the appropriate number of trays below the first tray (and including the first tray) you specify are removed. If you are using the bottom-up scheme, the appropriate number of trays above the first tray (and including the first tray) you specify are removed. 4. Streams connected to a higher tray (numerically) are not affected; for example, if you are deleting 3 trays starting at tray number 6, a side draw initially at tray 5 remains there, but a side draw initially connected to tray 10 is now at tray 7. Any draw streams connected to trays 6,7 or 8 are deleted with your confirmation to do so. If you select the Side Stripper radio button or Side Rectifier radio button at the bottom of the property view, this affects the pressure profile. The pressure of the main tray section stage from which the liquid feed stream is drawn is used as the side stripper pressure, which is constant for all stages. The pressure of the main tray section stage from which the vapour feed -176 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -177 ww Thstream is drawn is used as the Side Rectifier pressure, which is constant for all stages. Pressures Page The Pressures page displays the pressure on each tray. Whenever two pressures are known for the tray section, HYSYS interpolates to find the intermediate pressures. For example, if you enter the Condenser and Reboiler Pressures through the Column Input Expert or Column property view, HYSYS calculates the top and bottom tray pressures based on the Condenser and Reboiler pressure drops. The intermediate tray pressures are then calculated by linear interpolation. User Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. Figure 2.133 For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.-177 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -178 Column-Specific Operations ww ThRating Tab The Rating tab contains the following pages: • Sizing • Nozzles • Heat Loss • Efficiencies • Pressure Drop Sizing Page The Sizing page contains the required information for correctly sizing column tray and packed sections. If the Sieve, Valve, Bubble Cap radio button with the Uniform Tray Data are selected, the following property view is shown. The tray section diameter, weir length, weir height, and the tray spacing are required for an accurate and stable dynamic simulation. You must specify all of the information on this page. The Quick Size button allows you to automatically and quickly size the tray parameters. The Quick Size calculations are based on the same calculations that are used in the Tray Sizing Utility. Figure 2.134 Each parameter is also discussed in Section 14.18 - Tray Sizing.-178 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -179 ww ThHYSYS only calculates the tray volume, based on the weir length, tray spacing, and tray diameter. For multipass trays, simply enter the column diameter and the appropriate total weir length. When you select the Packed radio button and the Uniform Tray Data section, the Sizing page changes to the property view shown below. The stage packing height, stage diameter, packing type, void fraction, specified surface area, and Robbins factor are required for the simple dynamic model. HYSYS uses the stage packing dimensions and packing properties to calculate the pressure flow relationship across the packed section. The required size information for the tray section can be calculated using the Tray Sizing utility. Figure 2.135 Packing Properties (Dynamics) Description Void Fraction Packing porosity, in other words, m3 void space/ m3 packed bed. Specific Surface Area Packing surface area per unit volume of packing (m-1).-179 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -180 Column-Specific Operations ww ThTo specify Chimney and Sump tray types, the Non Uniform Tray Data Option must be selected from the Section Properties group. The Non Uniform Tray Data Option allows you to model a column with high fidelity by adjusting tray rating parameters on a tray by tray basis. For a Trayed section of a column, you can adjust the Internal Type of tray, Tray Spacing, Diameter, Weir Height, Weir Length, Robbins Factor A packing-specific quantity used in the Robbins correlation, which is also called the dry bed packing factor (m-1). The Robbins correlation is used to predict the column vapour pressure drop. For the dry packed bed at atmospheric pressure, 2 the Robbins or packing factor is proportional to the vapour pressure drop. Static Holdup Static liquid, hst, is the m 3 liquid/ m 3 packed bed remaining on the packing after it has been fully wetted and left to drain. The static liquid holdup is a constant value. Include Loading Regime Term Loading regime term is the second term in the Robbins pressure drop equation, which is limited to atmospheric pressure and under vacuum but not at elevated pressures. When pressure is high, (in other words, above 1 atm), inclusion of the loading regime term may cause an unrealistically high pressure drop prediction. Figure 2.136 Packing Properties (Dynamics) Description-180 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -181 ww ThDC Volume, Flow Path and Weeping factor. For a Packed section of a column, you can adjust the Stage Packing Height, and Diameter. From the Internal Type drop-down list in the Detailed Sizing Information group, you can select alternative internal tray types on a tray by tray basis. The Chimney and Sump internals along with the weeping factor details are mentioned below. Nozzles Page The Nozzles page contains the elevations at which vapour and liquid enter or leave the tray section. Heat Loss Page The Heat Loss page allows you to specify the heat loss from individual trays in the tray section. You can select from either a Direct Q, Simple or Detailed heat loss model or have no heat loss from the tray sections. Detailed Sizing Information Description Internal Type Chimney - This allows a higher liquid level and does not have any liquid going down to the tray below. Although vapor can go up through it but it does not contact the liquid. The Chimney tray type can be designated on any tray. By default, the weeping factor is set to 0 and the stage efficiency is set to 5% on the Efficiencies page. The weir height and tray spacing is increased for a tray section. For a packed section stage packing height is increased. Sump - Only the bottom tray can be designated as a sump. By default, the efficiency is set to 5%. The tray spacing for a tray section and the stage packing height in a packed section are increased when using a Sump. Weeping Factor The weeping factor can be adjusted on a tray by tray basis. It is used to scale back or turn off weeping. By default the weeping factor is set to 1 for all internal types except the sump. Refer to Section 1.3.6 - Nozzles Page for more information.-181 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -182 Column-Specific Operations ww ThDirect Q Heat Flow Model The Direct Q model allows you to input the heat loss directly where the heat flow is distributed evenly over each tray section. Otherwise you have the heat loss calculated from the Heat Flow for each specified tray section. Using the checkbox, you can temporarily disable heat loss calculations without losing any Heat Loss data that is entered. Figure 2.137-182 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -183 ww ThSimple Heat Flow Model The Simple model allows you to calculate the heat loss by specifying: • The Overall U value • The Ambient Temperature°C Detailed Heat Flow Model The Detailed Heat Flow model allows you to specify more detailed heat transfer parameters. The detailed properties can be used on a tray to tray basis based on the temperature profile, conduction, and convection data specified. Figure 2.138 Figure 2.139 Refer to Section 1.6.1 - Detailed Heat Model in the HYSYS Dynamic Modeling guide for more information.-183 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -184 Column-Specific Operations ww ThEfficiencies Page As with steady state, you can specify tray efficiencies for columns in dynamics. However, you can only specify the overall tray efficiency; component tray efficiencies are only available in steady state. Pressure Drop Page The Pressure Drop page displays the information associated with the pressure drops (or pressures) across the tray section. Selecting the Rating Enabled checkbox turns on the pressure drop calculations as part of the column solution. The tray sizing utility calculates a pressure drop across each tray, you need to fix one end of the column (top or bottom), allowing the other trays to float with the calculations. You can select which end of the column to be fixed by selecting the appropriate radio button in the Fix Tray group. Figure 2.140 The Pressure Drop page uses the same calculation in the Tray Sizing utility to calculate the pressure drop for the tray sections when the column is running. In other words, using the traffics and geometries to determine what the pressure drop is.-184 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -185 ww ThThe Tray Section Pressure Drop field displays the absolute overall pressure change between the fixed tray and the last tray at the other end. Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the Tray Section. Performance Tab The Performance tab contains the following pages: • Pressure • Temperature • Flow • Summary • Hydraulics Figure 2.141 The PF Specs page is relevant to dynamics cases only. Refer to Section 1.3.10 - Worksheet Tab for more information.-185 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -186 Column-Specific Operations ww ThPressure Page The Pressure page contains a table that lists all the pressure for each tray. The table also includes the names of any inlet streams associated to a tray and the inlet streams’ pressure. Temperature Page The Temperature page contains a table that lists all the temperature for each tray. The table also includes the names of any inlet streams associated to a tray and the inlet streams’ temperature. Flow Page The Flow page contains a table that lists all the liquid and vapour flow rates for each tray. The table also includes the names of any inlet streams associated to a tray and the inlet streams’ flow rate. You can also change the unit of the flow rates displayed by selecting the unit from the Flow Basis drop- down list. There are four possible units: • Molar • Mass • Standard Liquid Volume • Actual Volume Summary Page The Summary page contains a table that displays the flow rates, temperature, and pressure for each tray. Hydraulics Page The Hydraulics page contains a table that displays the height and pressure of Dry Hole DP, Static Head, and Height over Weir, and tray residence time.-186 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -187 ww ThThe tray residence time is computed as: Where the Tray Liquid Molar Flow Rate is the maximum between the liquid molar flow rate from above the tray plus the liquid side feed molar flow rates and the liquid molar flow rate to below the tray plus the liquid side product molar flow rates. The residence time of every tray is permanently compared against the column (composition) integrating step size to verify the accuracy of the dynamic simulation. The adopted criterion is: Every tray residence time must be at least four times as long as the column integrating step. Dynamics Tab The Dynamics tab contains the following pages: • Specs • Holdup • Static Head • StripChart Specs Page The Specs page contains the Nozzle Pressure Flow k Factors for all the trays in the tray section. You can select to have HYSYS calculate the k value for all the trays by clicking the All Stages button. If you want HYSYS to calculate the k values for certain trays only, select the desired trays and click the Selected Stages button. HYSYS only calculates the k values for the selected Tray Residence Time Tray Liquid Holdup Tray Liquid Molar Flow Rate ----------------------------------------------------------------------⎝ ⎠ ⎛ ⎞=-187 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -188 Column-Specific Operations ww Thstages. The Use tower diameter method checkbox, when selected, calculates the k values for the column based on the column diameter. When the checkbox is cleared the k values are calculated using the results obtained from the steady state model, providing a smoother transition between your steady state model and dynamic model. The Model Weeping checkbox, when selected, takes into account any weeping that occurs on the tray sections and add the effects to your model. The Perform dry start up checkbox allows you to simulate a dry start up. Selecting this checkbox removes all the liquid from all the trays when the integrator starts. The Initialize From User checkbox allows you to start the simulation from conditions you specify. Selecting this checkbox, activates the Init HoldUp button. Click this button to enter the Figure 2.142 Weeping can start to occur on a tray when the dry hole pressure loss drops below 0.015 kPa. It allows liquid to drain to the stage below even if the liquid height is below the weir height.-188 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -189 ww Thinitial liquid mole fractions of each component and the initial flash conditions. The Fixed Pressure Profile checkbox allows you to simulate the column based on the fixed pressure profile. Pressure Profile The Fixed Pressure Profile checkbox allows you to run the column in Dynamic mode using the steady state pressure profile. This option simplifies the column solution for inexperienced users, and makes their transition from the steady state to dynamics simulation a bit easier. The pressure profile of a tray section is determined by the static head, which is caused mostly by the liquid on the trays, and the frictional pressure losses, which are also known as dry hole pressure loses. The frictional pressure losses are associated with vapour flowing through the tray section. The flowrate is determined by Equation (2.17). In HYSYS, the k-value is calculated by assuming: However, if the Fixed Pressure Profile option is selected, then the static head contribution can be subtracted and hence the You do not have to configure pressure control systems with this option. This option is not recommended for rigorous modeling work where the pressure can typically change on response to other events. (2.17) (2.18) flow k density friction pressure losses××= kα Tray diameter( )2-189 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -190 Column-Specific Operations ww Thvapour flow and the frictional pressure loss is known. This allows the k-values to be directly calculated to match steady state results more closely. Holdup Page The Holdup page contains a summary of the dynamic simulation results for the column. The holdup pressure, total volume, and bulk liquid volume results on a tray basis are contained in this property view. Double-clicking on a stage name in the Holdup column opens the stage property view. You can double-click on any cell within each row to view the advanced holdup properties for each specific tray section.-190 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -191 ww ThStatic Head Page The Static Head page enables you to select how the static head contributes to the calculation. Since static head contributions are often essential for proper column modeling, internal static head contributions are generally considered for the column model in any case, and should only be disabled under special circumstances. StripChart Page The Stripchart page allows you to select and create default strip charts containing various variable associated to the operation. Tee The property view for the Tee operation in the Column subflowsheet has all of the pages and inherent functionality contained by the Tee in the Main Environment with one addition, the Estimates page. Figure 2.143 Figure 2.144 Refer to Section 1.6.5 - Static Head in the HYSYS Dynamic Modeling guide for more information. Refer to Section 1.3.7 - Stripchart Page/Tab for more information. Refer to Chapter 6 - Piping Operations for more details on the property view of the TEE. Refer to the section on the General Features of the Solving Methods for information on which method supports Tee operation.-191 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -192 Column-Specific Operations ww ThOn the Estimates page, you can help the convergence of the Column subflowsheet's simultaneous solution by specifying flow estimates for the tee product streams. To specify flow estimates: 1. Select one of the Flow Basis radio buttons: Molar, Mass or Volume. 2. Enter estimates for any of the product streams in the associated fields next to the stream name. There are four buttons on the Estimates page, which are described in the table below. If the Tee operation is attached to the column (for example, via a draw stream), one tee split fraction specification is added to the list of column specifications for each tee product stream that you specify. As you specify the split fractions for the product streams, these values are transferred to the individual column specifications on the Monitor page and Specs page of the column property view. Button Related Setting Update Replaces all estimates except user specified estimates (in blue) with values obtained from the solution. Clear Selected Deletes the highlighted estimate. Clear Calculated Deletes all calculated estimates. Clear All Deletes all estimates. The additional pieces of equipment available in the Column subflowsheet are identical to those in the main flowsheet. For information on each piece of equipment, refer to its respective chapter. For example, for information on the Heat Exchanger, refer to Section 4.4 - Heat Exchanger in this manual. All operations within the Column subflowsheet environment are solved simultaneously.-192 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -193 ww ThRunning the Column Once you are satisfied with the configuration of your Column subflowsheet and you have specified all the necessary input, the next step is to run the Column solution algorithm. The iterative procedure begins when you click the Run button on the Column property view. The Run/Reset buttons can be accessed from any page of the Column property view. When the Run button on the Column property view is clicked, the Run/Reset buttons are replaced by a Stop button which, when clicked, terminates the convergence procedure. The Run button can then be clicked again to continue from the same location. Similarly, the Stop icon switches to a grey shading with the Run icon on the toolbar after it is activated. When you are working inside the Column build environment, the Column runs only when you click the Run button on the Column property view, or the Run icon on the toolbar. When you are working with the Column property view in the Main build environment, the Column automatically runs when you change: • A specification value after a converged solution has been reached. • The Active specifications, such that the Degrees of Freedom return to zero. Run The Run command begins the iterative calculations necessary to simulate the column described by the input. On the Monitor page of the Column property view, a summary showing the iteration number, equilibrium error, and the heat and specification errors appear. Detailed messages showing the When you are inside the Column build environment, a Run icon also appears on the toolbar, which has the same function as the Run button on the Column property view. On the toolbar, the Run icon and Stop icon are two separate icons. Whichever icon is toggled on has light grey shading. Run icon Stop icon Refer to Monitor Page from Section - Design Tab for more information.-193 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -194 Running the Column ww Thconvergence status are shown in the Trace Window. The default basis for the calculation is a modified “inside-out” algorithm. In this type of solution, simple equilibrium and enthalpy models are used in the inner loop, which solve the overall component and heat balances, vapour-liquid equilibrium, and any specifications. The outer loop updates the simple thermodynamic models with rigorous calculations. When the simulation is running, the status line at the bottom of the screen first tracks the calculation of the initial properties used to generate the simple models. Then the determination of a Jacobian matrix appears, which is used in the solution of the inner loop. Next, the status line reports the inner loop errors and the relative size of the step taken on each of the inner loop iterations. Finally, the rigorous thermodynamics is again calculated and the resulting equilibrium, heat, and spec errors reported. The calculation of the inner loop and the outer loop properties continues until convergence is achieved, or you determine that the column cannot converge and click Stop to terminate the calculation. If difficulty is encountered in converging the inner loop, the program occasionally recalculates the inner loop Jacobian. If no obvious improvement is being made with the printed equilibrium and heat and spec errors, click Stop to terminate the calculations and examine the available information for clues. Refer to Section - Column Troubleshooting for solutions to some common troubles encountered while trying to achieve the desired solution. Any estimates which appear in the Column Profile page and Estimates page are used as initial guesses for the convergence algorithm. If no estimates are present, HYSYS begins the convergence procedure by generating initial estimates. Refer to Estimates Page from Section - Parameters Tab for more information.-194 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -195 ww ThReset The Reset command clears the current Column solution, and any estimates appearing on the Estimates page of the Column property view. If you make major changes after getting a converged Column, it is a good idea to Reset to clear the previous solution. This allows the Column solver to start fresh and distance itself from the previous solution. If you make only minor changes to the Column, try clicking Run before Resetting. Once the column calculation has started it continues until it has either converged, has been terminated due to a mathematically impossible condition, (for example being unable to invert the Jacobian matrix), or it has reached the maximum number of iterations. Other than these three situations, calculations continue indefinitely in an attempt to solve the column unless the Stop button is clicked. Unconverged results can be analysed, as discussed in Section - Column Troubleshooting. Column Troubleshooting Although HYSYS does not require any initial estimates for convergence, good estimates of top and bottom temperatures and one product accelerate the convergence process. Detailed profiles of vapour and liquid flow rates are not required. However, should the column have difficulty, the diagnostic output printed during the iterations provides helpful clues on how the tower is performing. If the equilibrium errors are approaching zero, but the heat and spec errors are staying relatively constant, the specifications are likely at fault. If both the equilibrium errors and the heat and spec errors do not appear to be getting anywhere, then examine all your input (for example the initial estimates, the specifications, and the tower configuration). In running a column, keep in mind that the Basic Column Parameters cannot change. By this, it is meant that column pressure, number of trays, feed tray locations, and extra -195 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -196 Column Troubleshooting ww Thattachments such as side exchanger and pump around locations remain fixed. To achieve the desired specifications the Column only adjusts variables which have been specified as initial estimates, such as reflux, side exchanger duties, or product flow rates. This includes values that were originally specifications but were replaced, thereby becoming initial estimates. It is your responsibility to ensure that you have entered a reasonable set of operating conditions (initial estimates) and specifications (Basic Column Parameters) that permit solution of the column. There are obviously many combinations of column configurations and specifications that makes convergence difficult or impossible. Although all these different conditions could not possibly be covered here, some of the more frequent problems are discussed in the following sections. Heat and Spec Errors Fail to Converge This is by far the most frequent situation encountered when a column is unable to satisfy the allowable tolerance. The following section gives the most common ailments and remedies. Poor Initial Estimates Initial estimates are important only to the extent that they provide the initial starting point for the tower algorithm. Generally, poor guesses simply cause your tower to converge more slowly. However, occasionally the effect is more serious. Consider the following: • Check product estimates using approximate splits. A good estimate for the tower overhead flow rate is to add up all the components in your feed which are expected in the overheads, plus a small amount of your heavy key component. If the tower starts with extremely high errors, check to see that the overhead estimate is smaller than the combined feed rates.-196 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -197 ww Th• Poor reflux estimates usually do not cause a problem except in very narrow boiling point separations. Better estimates are required if you have high column liquid rates relative to vapour rates, or vice versa. • Towers containing significant amounts of inert gases (for example H2, N2, and so forth), require better estimates of overhead rates to avoid initial bubble point problems. A nitrogen rejection column is a good example. Input Errors It is good practice to check all of your input just before running your column to ensure that all your entries, such as the stage temperatures and product flow rates, appear reasonable: • Check to ensure that your input contains the correct values and units. Typical mistakes are entering a product flow rate in moles/hr when you really meant to enter it in barrels/day, or a heat duty in BTU/hr instead of E+06 BTU/hr. • When specifying a distillate liquid rate, make sure you have specified the Distillate rate for the condenser, not the Reflux rate. • If you change the number of trays in the column, make sure you have updated the feed tray locations, pressure specifications, and locations of other units such as side exchangers on the column. • If the tower fails immediately, check to see if all of your feeds are known, if a feed was entered on a non-existent tray, or if a composition specification was mistakenly entered for a zero component. To see the initial estimates, click the View Initial Estimates button on the Monitor page of the column property view. Clicking the Input Summary button on the Monitor page of the column property view displays the column input in the Trace Window.-197 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -198 Column Troubleshooting ww ThIncorrect Configuration For more complex tower configurations, such as crude columns, it is more important that you always review your input carefully before running the tower. It is easy to overlook a stripping feed stream, side water draw, pump around or side exchanger. Any one of these omissions can have a drastic effect on the column performance. As a result, the problem is not immediately obvious until you have reviewed your input carefully or tried to change some of the specifications. • Check for trays which have no counter-current vapour- liquid traffic. Examples of this are having a feed stream on a tray that is either below the top tray of an un- refluxed tower or a tower without a top lean oil feed, or placing a feed stream above the bottom stage of a tower that does not have a bottom reboiler or a stripping feed stream below it. In both cases the trays above or below the feed tray become single phase. Since they do not represent any equilibrium mass transfer, they should be removed or the feed should be moved. The tower cannot converge with this configuration. • The tower fails immediately if any of the sidestrippers do not have a stripping feed stream or a reboiler. If this should occur, a message is generated stating that a reboiler or feed stream is missing in one of the sidestrippers. • Make sure you have installed a side water draw if you have a steam-stripped hydrocarbon column with free water expected on the top stage. • Regardless of how you have approached solving crude columns in the past, try to set up the entire crude column with your first run, including all the side strippers, side exchangers, product side draws, and pump arounds attached. Difficulties arise when you try to set up a more simplified tower that does not have all the auxiliary units attached to the main column, then assign product specs expected from the final configuration. Impossible Specifications Impossible specifications are normally indicated by an unchanging heat and spec error during the column iterations even though the equilibrium error is approaching zero. To get around this problem you have to either alter the column configuration or operating pressure or relax/change one of the -198 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -199 ww Thproduct specifications. • You cannot specify a temperature for the condenser if you are also using subcooling. • If you have zero liquid flows in the top of the tower, either your top stage temperature spec is too high, your condenser duty is too low, or your reflux estimate is too low. • If your tower shows excessively large liquid flows, either your purity specs are too tight for the given number of trays or your Cooler duties are too high. • Dry trays almost always indicate a heat balance problem. Check your temperature and duty specifications. There are a number of possible solutions: fix tray traffic and let duty vary; increase steam rates; decrease product makes; check feed temperature and quality; check feed location. • A zero product rate could be the result of an incorrect product spec, too much heat in the column which eliminates internal reflux, or the absence of a heat source under a total draw tray to produce needed vapour. Conflicting Specifications This problem is typically the most difficult to detect and correct. Since it is relatively common, it deserves considerable attention. • You cannot fix all the product flow rates on a tower. • Avoid fixing the overhead temperature, liquid and vapour flow rates because this combination offers only a very narrow convergence envelope. • You cannot have subcooling with a partial condenser. • A cut point specification is similar to a flow rate spec; you cannot specify all flows and leave one unspecified and then specify the cut point on that missing flow. • Only two of the three optional specifications on a pump around can be fixed. For example, duty and return temperature, duty and pump around rate, and so forth. • Fixing column internal liquid and vapour flows, as well as duties can present conflicts since they directly affect each other. • The bottom temperature spec for a non-reboiled tower must be less than that of the bottom stage feed. • The top temperature for a reboiled absorber must be greater than that of the top stage feed unless the feed goes through a valve. • The overhead vapour rate for a reboiled absorber must be greater than the vapour portion of the top feed.-199 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -200 References ww ThHeat and Spec Error Oscillates While less common, this situation can also occur. It is often caused by poor initial estimates. Check for: • Water condensation or a situation where water alternately condenses and vapourizes. • A combination of specifications that do not allow for a given component to exit the column, causing the component to cycle in the column. • Extremely narrow boiling point separations can be difficult since a small step change can result in total vapourization. First, change the specifications so that the products are not pure components. After convergence, reset the specifications and restart. Equilibrium Error Fails to Converge This is almost always a material balance problem. Check the overall balance. • Check the tower profile. If the overhead condenser is very cold for a hydrocarbon-steam column, you need a water draw. Normally, a side water draw should be added for any stage below 200oF. • If the column almost converges, you may have too many water draws. Equilibrium Error Oscillates This generally occurs with non-ideal towers, such as those with azeotropes. Decreasing the damping factor or using adaptive damping should correct this problem. References 1 Sneesby, Martin G., Simulation and Control of Reactive Distillation, Curtin University of Technology, School of Engineering, March 1998. Refer to Section - Parameters Tab for more information-200 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Column Operations -201 ww Th 2 Henry, Kister., Distillation Design, (1992), pp 497-499.-201 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete -202 References ww Th-202 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Electrolyte Operations 3-1 ww Th3 Electrolyte Operations3-1 3.1 Introduction................................................................................... 2 3.1.1 Adding Electrolyte Operations .................................................... 3 3.2 Crystallizer Operation .................................................................... 4 3.2.1 Design Tab .............................................................................. 6 3.2.2 Rating Tab............................................................................... 9 3.2.3 Worksheet Tab ......................................................................... 9 3.2.4 Dynamic Tab.......................................................................... 10 3.3 Neutralizer Operation .................................................................. 10 3.3.1 Design Tab ............................................................................ 13 3.3.3 Worksheet Tab ....................................................................... 17 3.3.3 Worksheet Tab ....................................................................... 17 3.3.4 Dynamic Tab.......................................................................... 17 3.4 Precipitator Operation ................................................................. 18 3.4.1 Design Tab ............................................................................ 20 3.4.2 Rating Tab............................................................................. 24 3.4.3 Worksheet Tab ....................................................................... 24 3.4.4 Dynamic Tab.......................................................................... 24 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 3-2 Introduction ww Th3.1 Introduction Most HYSYS unit operations can be used when working with the OLI Electrolyte property package. The following HYSYS unit operations are not available in the OLI Electrolyte property package: • Pipe Segment • Reactors • Short Cut Column • Three Phase Distillation • Compressible Gas Pipe In addition to the typical HYSYS unit operations, three new electrolyte simulations, specific to OLI Electrolyte property package have been added. The table below describes the three new electrolyte simulations.: Press F4 to open the Object Palette. The Object Palette shows the unit operations available in OLI Electrolyte property package by active icons. Operation Icon Description Neutralizer Neutralizer operation is used to control PH value for a process material stream. Precipitator Precipitator operation is used to achieve a specified aqueous ionic species concentration in its product stream. Crystalizer Crystallizer operation is used to estimate and control solid concentration in a product stream. The electrolyte operations are only available if your case is an electrolyte system (the selected fluid package must support electrolyte).3-2 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Electrolyte Operations 3-3 ww Th3.1.1 Adding Electrolyte Operations There are two ways you can add an electrolyte operation to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Electrolyte Equipment radio button. 3. From the list of available unit operations, select the electrolyte operation you want. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Click the Electrolyte Ops icon. The electrolyte object palette appears. 3. Double-click the electrolyte operation you want. The property view for the selected electrolyte operation appears. The following sections describe the function of each electrolyte unit operation. Figure 3.1 Electrolyte Ops icon3-3 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 3-4 Crystallizer Operation ww Th3.2 Crystallizer Operation The Crystallizer operation models the crystallization of a fully defined inlet stream to attain a specified amount of selected solids concentration that is present in the effluent. The Crystalizer operation contains four tabs: Design, Rating, Worksheet, and Dynamics. Theory The figure below represents the crystallizer model. A Crystallizer has a product stream that contains liquid and solid. By adjusting the operation condition like Crystallizer temperature and pressure or heat duty, the amount of solid or solid component product in the liquid stream can be controlled or estimated. The Crystallizer vessel is modeled as a perfect mixing in HYSYS. Heat can be added or removed from the Crystallizer, and a simple constant duty model is assumed. Boundary Condition Since the electrolyte flow sheet implements a forward calculation only, the Crystallizer does not solve until the Inlet Stream is defined. If the energy stream is not specified, the crystallizer is treated as an adiabatic one. You must specify two Figure 3.23-4 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Electrolyte Operations 3-5 ww Thof the following to define the boundary condition for crystallizer solver to proceed: • T. Crystallizer temperature • P or DeltP. Crystallizer’s pressure or pressure drop • E. Heat Duty • Fcry. Crystal product flow rate (total or a specific component) • Fvap. Vapor flow Equations The crystallizer solves under the constraint of mass and energy balance equations: with the target solid equation: where: Fsolid(product stream) = solid flow rate in the outlet liquid stream Fsolid(specified) = desired solid flow rate in the outlet liquid stream E = energy/heat transfer rate M = mass flow rate (3.1) (3.2) (3.3) Eproduct stream Evapour stream+ Einlet stream Eduty+= Mproduct stream Mvapour stream+ Minlet stream= Fsolid product stream( ) Fsolid specified( )– 0=3-5 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 3-6 Crystallizer Operation ww Th3.2.1 Design Tab The Design tab contains the following pages: • Connections • Parameters • Solver • User Variables • Notes Connections Page You can specify the inlet stream, outlet stream, and energy stream on the Connections page. Figure 3.3 Object Description Name You can change the name of the operation by typing a new name in the field. Inlet You can enter one or more inlet streams in this table, or use the drop-down list to select the streams you want. Vapour Outlet You can enter the name of the vapour product stream or use the drop-down list to select a pre-defined stream. Liquid Outlet You can enter the name of the product stream in this field or use the drop-down list to select a pre-defined stream. 3-6 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Electrolyte Operations 3-7 ww ThParameters Page On the Parameters page, you can specify the pressure drop and solid output flow rate. The four radio buttons allow you to control the specified solid output in the liquid stream by crystallization operation: • Mole Flow. Select this radio button to specify the flow rate value in mole basis. • Mass Flow. Select this radio button to specify the flow rate value in mass basis. • Component. Select this radio button to control a specified solid component in the operation. • Total. Select this radio button to control the total solid flow rate in the liquid stream. This page also displays the degrees of freedom for the operation at the current setting. Energy (Optional) You can add an energy stream to the operation by selecting an energy stream from the drop-down list or typing the name for a new energy stream. Fluid Package Displays the fluid package currently being used by the operation. You can select a different fluid package from the drop-down list. Figure 3.4 The flow rate of crystal product depends on the solubility of the product at the crystallizer’s operation condition. Object Description3-7 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 3-8 Crystallizer Operation ww ThSolver Page On the Solver page, you can specify the upper and lower bounds of the manipulated variable, the tolerance of specified variable, and the maximum iterations/steps of calculations the solver performs before stopping. Crystallizer operates on various boundary conditions. The following table lists all the possible options. As soon as the operation condition (as listed in the Specified Variables column) is known, the crystallizer will start to solve. The Crystallizer Calculates column lists some of the calculation variables for the operation. Figure 3.5 Specified Variables Crystallizer Calculates Temperature & Pressure Heat Duty, Crystal product flow rate, Vapour flow rate Temperature & Heat Duty Pressure, Crystal product flow rate, Vapor flow rate Temperature & Crystal product flow rate Pressure, Heat Duty, Vapor flow rate Temperature & Vapour flow rate Pressure, Crystal product flow rate, Heat Duty Pressure & Heat Duty Temperature, Crystal product flow rate, Vapor flow rate Pressure & Crystal product flow rate Temperature, Heat Duty, Vapor flow rate Pressure & Vapour flow rate Temperature, Crystal product flow rate, Heat Duty3-8 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Electrolyte Operations 3-9 ww ThThe bounds for the Manipulated Variables and tolerances for the Target Variables are shown on the Solver tab and are user- modifiable. As well, the Active status for the Manipulated Variable used by the solver is shown. However, this flag is meant for displaying information only thus cannot be changed. User Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. 3.2.2 Rating Tab Crystalizer operation currently does not support any rating calculations. 3.2.3 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the Crystallizer. The PF Specs page is relevant to dynamics cases only. For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab. Refer to Section 1.3.10 - Worksheet Tab for more information.3-9 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 3-10 Neutralizer Operation ww ThThe Crystallizer Worksheet tab also has one extra page called the Solids page. On the Solids page, you can view the precipitate molar and mass flow rates. 3.2.4 Dynamic Tab Crystalizer operation currently does not support dynamic mode. 3.3 Neutralizer Operation The Neutralizer operation models the neutralization of a fully defined inlet stream, and allows you to adjust the pH value in the effluent stream. The Neutralizer property view contains four tabs: • Design • Rating • Worksheet • Dynamics Figure 3.63-10 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Electrolyte Operations 3-11 ww ThTheory The figure below represents the neutralizer model. Through adjusting the Reagent Stream variables (flow rate), the PH value for the targeting stream (Liquid Stream) could be controlled at the level as required. • Inlet Stream. At least one inlet stream. • Reagent Stream. Reagent stream must be a free stream, that is, not attached to any other unit operations. • Product Stream. A Neutralizer has two product streams, a vapour stream and a liquid stream. The liquid stream controls the pH value. • pH. The liquid stream’s pH value that is to be controlled must fall in the range between the pH values of the Reagent and inlet streams to guarantee the solution. • Q. The energy stream is optional. When no energy stream is attached, an adiabatic operation is assumed. The Neutralizer vessel is modeled as perfect mixing. Heat can be added or removed from the Neutralizer, and a simple constant duty model is assumed. Boundary Condition Since the electrolyte flow sheet implements a forward calculation only, the Neutralizer does not solve until both inlet and Reagent streams are defined. Figure 3.73-11 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 3-12 Neutralizer Operation ww ThIf the energy stream is not specified, the neutralizer is treated as an adiabatic one. If the energy stream is specified, you must specify either the Neutralizer temperature or the duty of the energy stream. Pressure drop of the neutralizer must be specified or can be calculated out from the inlet and product streams. Solving Options The Neutralizer has two different solving options, depending on what you specify. Option 1 (Targeting pH Value is Not Specified) If the targeting pH value is not specified, the Neutralizer operates as a mixer for the inlet and Reagent streams. The product stream accepts the mixed result as is. Option 2 (Targeting pH Value is Specified) If the targeting pH value is specified, the flow rate of the Reagent stream must be left unspecified. The Reagent stream is used as an adjusting variable for neutralizer solver to search for a solution to meet the targeting pH value at the outlet stream. Equations The Neutralizer solves under the constraint of the following equations. (3.4) (3.5) (3.6) pHproduct stream pHspecified 0=– pHspecified pHinlet stream pHReagent stream,{ }⊂ Eproduct stream Einlet stream EReagent stream Eduty+ +=3-12 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Electrolyte Operations 3-13 ww Thwhere: E = energy/heat transfer rate M = mass flow rate 3.3.1 Design Tab The Design tab contains the following pages: • Connections • Parameters • Solver • User Variables • Notes Connections Page You can specify the inlet stream, outlet stream, and energy stream on the Connections page. (3.7) Figure 3.8 Mproduct stream Minlet stream MReagent stream+=3-13 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 3-14 Neutralizer Operation ww ThParameters Page On the Parameters page, you can specify the pressure drop and an initial pH value. This page also displays the degrees of freedom for the operation at the current setting, and the actual pH balance in the operation when the operation reaches a solution. Object Description Name You can change the name of the operation by typing a new name in the field. Inlet You can enter one or more inlet streams in this table, or use the drop-down list to select the streams you want. Reagent Stream You can enter a name for the reagent stream or use the drop-down list. Reagent stream must be a free stream, that is, not attached to any other unit operations. Vapour Outlet You can type the name of the vapour product stream or use the drop-down list to select a pre-defined stream. Liquid Outlet You can type the name of the product stream in this field or use the drop-down list to select a pre-defined stream. Energy (Optional) You can add an energy stream to the operation by selecting an energy stream from the drop-down list or typing the name for a new energy stream. Fluid Package Displays the fluid package currently being used by the operation. You can select a different fluid package from the drop-down list. Figure 3.93-14 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Electrolyte Operations 3-15 ww ThThe pH value in a solution is defined in a mathematical format: where: [H+] = concentration of H+ in a solution, mol/l According to Equation (3.5), the pH (specified) value must be specified between the pH values of the inlet and the Reagent streams. An adjustment of Reagent Stream’s variables, for example, temperature, pressure, and compositions, can bracket the pH (specified) value to meet the constraint Equation (3.5). As soon as the specified pH value is bracketed according to Equation (3.5), the pH value of the product stream in Equation (3.4) can be obtained by adjusting the flow rate of the Reagent stream. Solver Page On the Solver page, you can specify the upper and lower bounds of the manipulated variable, the tolerance of specified variable, and the maximum iterations/steps of calculations the solver performs before stopping. Object Description Delta P You must specify the pressure drop for the Neutralizer or specify inlet and product streams with known pressure. pH Spec You can specify the product stream’s pH value in this field. The pH value that is to be controlled must fall in the range between the pH values of the Reagent and Inlet Streams for calculations to converge. (3.8)pH 10 H+[ ]log–=3-15 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 3-16 Neutralizer Operation ww ThCurrently only the flow rate of a defined Reagent stream is used as an adjustable variable to the solver. Here a defined Reagent stream means that the stream can be flashed to get a solution with the specified variables meeting the degree of freedom. According to HYSYS, a defined stream can have the following variables: • T. Stream Temperature • P. Stream Pressure • F. Stream Flow Rate • x. Stream Component Compositions • H. Stream Enthalpy • V. Stream Vapor Fraction User Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. Figure 3.10 For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.3-16 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Electrolyte Operations 3-17 ww Th3.3.2 Rating Tab Neutralizer operation currently does not support any rating calculations. 3.3.3 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the Neutralizer. 3.3.4 Dynamic Tab Neutralizer operation currently does not support dynamic mode. Figure 3.11 The PF Specs page is relevant to dynamics cases only. Refer to Section 1.3.10 - Worksheet Tab for more information.3-17 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 3-18 Precipitator Operation ww Th3.4 Precipitator Operation The Precipitator models the precipitation of a selected ion in a stream entering the operation to achieve a specified target concentration in the effluent stream. The Precipitator operation contains four tabs: • Design • Rating • Worksheet • Dynamics Theory The figure below represents the precipitator model. Through adjusting the flow rate of the Reagent stream, the concentration of the targeting ion could be controlled at the desired level as you require in the outlet stream. To ensure that the Precipitator functions properly, the ions in the Reagent stream must be capable of reacting with the target ion under the specified operation condition. The formation of a precipitate in the outlet stream reduces the target ion concentration that entered the operation in the inlet stream. • Inlet Stream. At least one inlet stream. Figure 3.123-18 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Electrolyte Operations 3-19 ww Th• Reagent Stream. Reagent stream must be a free stream, that is, not attached to any other unit operations. • Liquid Stream. A Precipitator must have one liquid stream (contains liquid and solid) that is a targeting stream for the control of ion concentration through precipitation. • Ion Concentration. The product stream’s ion concentration value can be controlled by dilution or precipitation. • Q. The energy stream is optional. The Precipitator is modeled as a perfect mixing in HYSYS. Heat can be added or removed from the precipitator through a duty stream, and a simple constant duty model is assumed. Boundary Condition Since the electrolyte flow sheet implements a forward calculation only, the Precipitator does not solve until both inlet and Reagent streams are defined. If the energy stream is not specified, the precipitator is treated as an adiabatic one. If the energy stream is specified, you must specify either the Precipitator temperature or the duty of the energy stream. Pressure drop of the Precipitator must be either specified or can be calculated from the inlet and product streams. Solving Options The Precipitator has two different solving options, depending on what you specify. • Option 1 (Targeting Ionic Species Not Specified) If the targeting ionic species is not specified, the Precipitator simply mixes the inlet stream with the Reagent stream. The product stream accepts the mixed result as is. • Option 2 (Targeting Ionic Species is Specified) If the targeting ionic species is specified for the control of its concentration, the flow rate of the Reagent stream is used as iterative variables for the precipitator solver to search for a solution.3-19 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 3-20 Precipitator Operation ww ThEquations The precipitator solves under the constraint of the following equations: where: Cion = concentration of the targeting ion species E = energy/heat transfer rate M = mass flow rate 3.4.1 Design Tab The Design tab contains the following pages: • Connections • Parameters • Solver • User Variables • Notes (3.9) (3.10) (3.11) Cion product stream( ) Cion specified( )< Eproduct stream Evapour stream Eduty+ + Einlet stream EReagent stream+= Mproduct stream Mvapour stream+ Minlet stream MReagent stream+=3-20 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Electrolyte Operations 3-21 ww ThConnections Page You can specify the inlet stream, outlet stream, and energy stream on the Connections page. Figure 3.13 Object Description Name You can change the name of the operation by typing a new name in the field. Inlet You can enter one or more inlet streams in this table, or use the drop-down list to select the streams you want. Reagent Stream You can enter a name for the reagent stream or use the drop-down list. Reagent stream must be a free stream, that is, not attached to any other unit operations. Vapour Outlet You can enter the name of the vapour product stream or use the drop-down list to select a pre-defined stream. Liquid Outlet You can enter the name of the product stream in this field or use the drop-down list to select a pre-defined stream. Energy (Optional) You can add an energy stream to the operation by selecting an energy stream from the drop-down list or typing the name for a new energy stream. Fluid Package Displays the fluid package currently being used by the operation. You can select a different fluid package from the drop-down list.3-21 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 3-22 Precipitator Operation ww ThParameters Page On the Parameters page, you can specify the pressure drop, select the ion to be controlled, and specify the ion concentration in the liquid stream. This page also displays the degrees of freedom for the operation at the current setting, and the actual ion concentration value in the operation when the operation has reached a solution. Figure 3.14 Object Description Delta P You must specify the pressure drop for the Precipitator or specify inlet and product streams with known pressure. Controlled Ion Select the ion component you want to control from the drop-down list, or type the name of the ion component in the field. Ion Spec The concentration of ion from the inlet stream can be controlled via the following exercises: • Dilution. If the mixing of reagent and inlet streams does not produce the ion to be controlled and the ion concentration in the Reagent stream is less than that in the inlet stream, an increase of flow rate of the Reagent stream can achieve the target. In this case, the Chemistry Model does not have to include Solid. • Precipitation. Form precipitator by mixing inlet and Reagent streams. The change of Regent stream variables: temperature, pressure, flow rate or composition may achieve the target. To form precipitator, OLI chemistry model must include Solid. 3-22 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Electrolyte Operations 3-23 ww ThSolver Page On the Solver page, you can specify the upper and lower bounds of the manipulated variable, the tolerance of specified variable, and the maximum iterations/steps of calculations the solver performs before stopping. Currently, the flow rate of the Reagent stream is the manipulated variable used by the precipitator solver to search for a solution. User Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. Figure 3.15 For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.3-23 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 3-24 Precipitator Operation ww Th3.4.2 Rating Tab Precipitator operation currently does not support any rating calculations. 3.4.3 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the Precipitator. 3.4.4 Dynamic Tab Precipitator operation currently does not support dynamic mode. The PF Specs page is relevant to dynamics cases only. Refer to Section 1.3.10 - Worksheet Tab for more information.3-24 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-1 ww Th4 Heat Transfer Operationsw.cadfamily.com EMa e document is for study 4.1 Air Cooler....................................................................................... 3 4.1.1 Theory.................................................................................... 3 4.1.2 Air Cooler Property View............................................................ 8 4.1.3 Design Tab .............................................................................. 8 4.1.4 Rating Tab............................................................................. 10 4.1.5 Worksheet Tab ....................................................................... 12 4.1.6 Performance Tab .................................................................... 12 4.1.7 Dynamics Tab ........................................................................ 13 4.1.8 HTFS - ACOL Tab.................................................................... 16 4.2 Cooler/Heater.............................................................................. 45 4.2.1 Theory.................................................................................. 45 4.2.2 Heater or Cooler Propety View ................................................. 47 4.2.3 Design Tab ............................................................................ 48 4.2.4 Rating Tab............................................................................. 50 4.2.5 Worksheet Tab ....................................................................... 52 4.2.6 Performance Tab .................................................................... 53 4.2.7 Dynamics Tab ........................................................................ 56 4.3 Fired Heater (Furnace) ................................................................ 62 4.3.1 Theory.................................................................................. 64 4.3.2 Fired Heater Property View ...................................................... 71 4.3.3 Design Tab ............................................................................ 72 4.3.4 Rating Tab............................................................................. 75 4.3.5 Worksheet Tab ....................................................................... 82 4.3.6 Performance Tab .................................................................... 82 4.3.7 Dynamics Tab ........................................................................ 874-1 il:cadserv21@hotmail.com only,if tort to your rights,please inform us,we will delete 4-2 Heat Transfer Operations www.cadfamily.com EMa The document is for study 4.4 Heat Exchanger ............................................................................89 4.4.1 Theory ..................................................................................90 4.4.2 Heat Exchanger Property View ..................................................94 4.4.3 Design Tab .............................................................................95 4.4.4 Rating Tab............................................................................108 4.4.5 Worksheet Tab......................................................................125 4.4.6 Performance Tab ...................................................................125 4.4.7 Dynamics Tab.......................................................................130 4.4.8 HTFS-TASC Tab.....................................................................138 4.5 LNG.............................................................................................163 4.5.1 Theory ................................................................................164 4.5.2 LNG Property View ................................................................168 4.5.3 Design Tab ...........................................................................169 4.5.4 Rating Tab............................................................................179 4.5.5 Worksheet Tab......................................................................186 4.5.6 Performance Tab ...................................................................186 4.5.7 Dynamics Tab.......................................................................193 4.5.8 HTFS-MUSE Tab....................................................................200 4.6 References..................................................................................2164-2 il:cadserv21@hotmail.com only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-3 ww Th4.1 Air Cooler The Air Cooler unit operation uses an ideal air mixture as a heat transfer medium to cool (or heat) an inlet process stream to a required exit stream condition. One or more fans circulate the air through bundles of tubes to cool process fluids. The air flow can be specified or calculated from the fan rating information. The Air Cooler can solve for many different sets of specifications including the: • Overall heat transfer coefficient, UA • Total air flow • Exit stream temperature 4.1.1 Theory Steady State The Air Cooler uses the same basic equation as the Heat Exchanger unit operation; however, the Air Cooler operation can calculate the flow of air based on the fan rating information. The Air Cooler calculations are based on an energy balance between the air and process streams. For a cross-current Air Cooler, the energy balance is calculated as follows: where: Mair = air stream mass flow rate Mprocess = process stream mass flow rate H = enthalpy Mair(Hout - Hin)air = Mprocess(Hin - Hout)process (4.1)4-3 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-4 Air Cooler ww ThThe Air Cooler duty, Q, is defined in terms of the overall heat transfer coefficient, the area available for heat exchange, and the log mean temperature difference: where: U = overall heat transfer coefficient A = surface area available for heat transfer = log mean temperature difference (LMTD) Ft = correction factor The LMTD correction factor, Ft, is calculated from the geometry and configuration of the Air Cooler. ACOL Functionality In Steady State mode, you can also access certain ACOL functions on the HTFS-ACOL tab. You must install and license ACOL 6.4 before you can access the ACOL functions. Dynamic In dynamics, the Air Cooler tube is capable of storing inventory like other dynamic unit operations. The direction of the material flowing through the Air Cooler operation is governed by the pressures of the surrounding unit operations. Heat Transfer The Air Cooler uses the same basic energy balance equations as the Heat Exchanger unit operation. The Air Cooler calculations are based on an energy balance between the air and process streams. (4.2)Q UAΔTLMFt–= ΔTLM4-4 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-5 ww ThFor a cross-current Air Cooler, the energy balance is shown as follows: where: Mair = air stream mass flow rate Mprocess = process stream mass flow rate = density H = enthalpy V = volume of Air Cooler tube Dynamic Specifications HYSYS requires three overall specifications in order for the Air Cooler unit operation to fully solve in Dynamic mode: (4.3) Dynamic Specifications Description Overall UA The Overall UA is the product of the Overall Heat Transfer Coefficient (U) and the total area available for heat transfer (A). You can specify the value of UA on the Parameters page of the Design tab. Mprocess Hin Hout–( )process Mair Hin Hout–( )air– ρ d VHout( )process dt ---------------------------------------= ρ 4-5 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-6 Air Cooler ww ThFan Rating Information The Fan Rating information characterizes the flow rate and cooling properties of the air flowing through the Air Cooler. HYSYS provides two methods to determine the Fan Rating information. For the Air Cooler Simple Design method, specify the following variables in the Sizing page of the Rating tab: • Demanded Speed • Design Speed • Design Flow • Max Acceleration (optional) For the ACOL Design method, specify: • The Air Mass Flow Rate variable in the Sizing page of the Rating tab • The various Fan parameters in the HTFS - ACOL tab Pressure Drop HYSYS provides two options to determine the pressure difference between the inlet and outlet process streams: • Specified pressure drop (constant value) • Calculated pressure drop from K-value (value may vary with time) These pressure drop specifications can be made on the Specs page of the Dynamics tab. Dynamic Specifications Description4-6 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-7 ww ThPressure Drop The pressure drop of the Air Cooler can be determined in one of two ways: • Specify the pressure drop. This method assumes the pressure difference between the inlet process stream and outlet process stream is constant. This method is applicable to both Steady State and Dynamic modes. • Define a pressure flow relation in the Air Cooler by specifying a k-value. This method assumes the pressure difference between the inlet process stream and outlet process stream varies with time. This method is applicable only to Dynamic mode. If the pressure flow option is chosen for pressure drop determination in the Air Cooler, a k-value is used to relate the frictional pressure loss and flow through the exchanger. This relation is similar to the general valve equation: The general flow equation uses the pressure drop across the Heat Exchanger without any static head contributions. The quantity, P1 - P2, is defined as the frictional pressure loss which is used to “size” the Air Cooler with a k-value. Using the pressure flow option, you must have an accurate k- value to generate valid/accurate results. HYSYS also provides a feature than enables you to calculate the k-value of the Air Cooler at steady state. This k-value can then be used in Dynamic mode to calculate the varying pressure difference between the inlet and outlet process streams. The following information is required for HYSYS to calculate the k-value in Steady State mode: • Completely defined inlet or outlet process stream (to obtain the flow and density variable value) • Pressure difference between the inlet and outlet stream • Solved Air Cooler operation HYSYS assumes no pressure difference in the air flowing (4.4)flow density k× P1 P2–= The Calculate K option is located in the Air Cooler property view, Dynamics tab, Specs page.4-7 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-8 Air Cooler ww Ththrough the Air Cooler operation. 4.1.2 Air Cooler Property View To add an Air Cooler to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar (or press F12). The UnitOps property view appears. 2. Click the Heat Transfer Equipment radio button. 3. From the list of available unit operations, select Air Cooler. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar (or press F4). The Object Palette appears. 2. Double-click the Air Cooler icon. The Air Cooler property view appears. 4.1.3 Design Tab The Design tab contains the following pages: • Connections • Parameters • User Variables • Notes Air Cooler icon4-8 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-9 ww ThConnections Page On the Connections page, you can specify the feed and product streams attached to the Air Cooler. You can change the name of the operation in the Name field. Parameters Page On the Parameters page, the following information appears: User Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Parameters Description Air Cooler Model Allows you to select HYSYS-Engines or HTFS-Engines. The HTFS-Engines options appears only if you have ACOL6.4 installed and licensed. The HTFS-Engines option allows you to access ACOL functions on the HTFS-ACOL tab. Process Stream Delta P Allows you to specify the pressure drops (DP) for the process stream side of the Air Cooler. The pressure drop can be calculated if both the inlet and exit pressures of the process stream are specified. There is no pressure drop associated with the air stream. The air pressure through the Cooler is assumed to be atmospheric. Overall UA Contains the value of the Overall Heat Transfer Coefficient multiplied with the Total Area available for heat transfer. The Air Cooler duty is proportional to the log mean temperature difference, where UA is the proportionality factor. The UA can either be specified or calculated by HYSYS. Configuration Displays the possible tube pass arrangements in the Air Cooler. There are seven different Air Cooler configurations to choose from. HYSYS determines the correction factor, Ft, based on the selected Air Cooler configuration. Air Intake/ Outlet Temperatures The inlet and exit air stream temperatures can be specified or calculated by HYSYS. Air Intake Pressure The inlet air stream pressure has a default value of 1 atm. For more information refer to Section 1.3.8 - User Variables Page/ Tab.4-9 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-10 Air Cooler ww ThNotes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation or the simulation case in general. 4.1.4 Rating Tab The Rating tab allows you to specify the fan rating information. The steady state and dynamic Air Cooler operations share the same fan rating information. The Rating tab contains the following pages: • Sizing page. The content of this page differs depending on which option you selected in the Air Cooler Model drop-down list on the Parameters page of the Design tab. If you selected HTFS-Engines, this page displays only one field: Air Mass Flow Rate. • Nozzles page. This page appears only if the HYSYS Dynamics license is activated. Sizing Page HYSYS-Engines In the Sizing page, the following fan rating information appears for the Air Cooler operation when the HYSYS-Engines option is selected on the Parameters page of the Design tab. In dynamics, the air flow must be calculated using the fan rating information. Fan Data Description Number of Fans Number of fans in the Air Cooler. Speed Actual speed of the fan in rpm (rotations per minute). For more information, refer to Section 1.3.5 - Notes Page/Tab.4-10 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-11 ww ThThe air flow through the fan is calculated using a linear relation: In dynamic mode only, the actual speed of the fan is not always equal to the demanded speed. The actual fan speed after each integration time step is calculated as follows: Each fan in the Air Cooler contributes to the air flow through the Cooler. The total air flow is calculated as follows: Demanded speed Desired speed of the fan. • Steady State mode. The demanded speed is always equal the speed of the fan. The desired speed is either calculated from the fan rating information or user- specified. • Dynamic mode. The demanded speed should either be specified directly or from a Spreadsheet operation. If a control structure uses the fan speed as an output signal, it is the demanded speed which should be manipulated. Max Acceleration Applicable only in Dynamic mode. It is the rate at which the actual speed moves to the demanded speed. Design speed The reference Air Cooler fan speed. It is used in the calculation of the actual air flow through the Cooler. Design air flow The reference Air Cooler air flow. It is used in the calculation of the actual air flow through the Cooler. Current air flow This can be calculated or user-specified. If the air flow is specified no other fan rating information needs to be specified. Fan Is On By default, this checkbox is selected. You have the option to turn on or off the air cooler as desired. When you clear the checkbox, the temperature of the outlet stream of the air cooler will be identical to that of the inlet stream. The Fan Is On checkbox has the same function as setting the Speed to 0 rpm. (4.5) (4.6) (4.7) Fan Data Description Fan Air Flow Speed Design Speed ------------------------------------ Design Flow×= Actual Speed Max Acceleration( )Δt Actual Speedo until Actual Speed + Demanded Speed = = Total Air Flow Fan Air Flow∑=4-11 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-12 Air Cooler ww ThSizing Page HTFS-Engines The Sizing page for HTFS Engines appears when the HTFS- Engines option is selected on the Parameters page of the Design tab. HYSYS air coolers can have multiple fans, and HYSYS calculates the airflow from the sum of the airflows of each fan. Nozzles Page The Nozzles page contains information regarding the elevation and diameter of the nozzles. The information provided in the Nozzles page is applicable only in Dynamic mode. 4.1.5 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the Air Cooler. 4.1.6 Performance Tab The Performance tab contains pages that display the results of the Air Cooler calculations. In HTFS-Engines option, you can only enter the total air mass flow rate for the air cooler. The PF Specs page is relevant to dynamics cases only. The Profiles page is relevant to dynamics cases only. Refer to Section 1.3.6 - Nozzles Page for more information. Refer to Section 1.3.10 - Worksheet Tab for more information.4-12 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-13 ww ThResults Page The information from the Results page is shown as follows: 4.1.7 Dynamics Tab The Dynamics tab contains the following pages: • Model • Specs • Holdup • Stripchart Results Description Working Fluid Duty This is defined as the change in duty from the inlet to the exit process stream: LMTD Correction Factor, Ft The correction factor is used to calculate the overall heat exchange in the Air Cooler. It accounts for different tube pass configurations. UA The product of the Overall Heat Transfer Coefficient, and the Total Area available for heat transfer. The UA can either be specified or calculated by HYSYS. LMTD The LMTD is calculated in terms of the temperature approaches (terminal temperature difference) in the exchanger, using the following uncorrected LMTD equation: where: Inlet/Outlet Process Temperatures The inlet and outlet process stream temperatures can be specified or calculated in HYSYS. Inlet/Outlet Air Temperatures The inlet and exit air stream temperatures can be specified or calculated in HYSYS. Air Inlet Pressure The inlet air stream pressure has a default value of 1 atm. Total Air flow The total air flowrate appears in volume and mass units. Hprocess in, Duty+ Hprocess out,= ΔTLM ΔT1 ΔT2– ΔT1 ΔT2( )⁄( )ln --------------------------------------= ΔT1 Thot out, Tcold in,–= ΔT2 Thot in, Tcold o, ut–=4-13 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-14 Air Cooler ww ThIn dynamics, the air flow must be calculated using the fan rating information. Model Page The Model page allows you to define how UA is defined in Dynamic mode. The value of UA is calculated as follows: where: UAsteadystate = UA value entered on the Parameters page of the Design tab. The Model page contains the UA Calculation group. which contains four fields: If you are working exclusively in Steady State mode, you are not required to change any of the values on the pages accessible through this tab. (4.8) (4.9) f1 = (mass flowrate / reference flowrate)^0.8 for air (4.10) f2 = (mass flowrate / reference flowrate)^0.8 for fluid (4.11) Field Description UA The steady state value of UA. This should be the same as the value entered on the Parameters tab. Reference air flow The reference flowrate for air. It is used to calculate the value of f1 as shown in Equation (4.10). Reference fluid flow The reference flowrate for the fluid. It is used to calculate the value of f2 as shown in Equation (4.11). Minimum flow scale factor The minimum scale factor used. If the value calculated by Equation (4.9) is smaller than this value, this value is used. UAdynamic F UAsteadystate×= F 2 f1 f2×× f1 f2+( ) -------------------------= the flow scale factor4-14 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-15 ww ThSpecs Page The Specs page contains information regarding the calculation of pressure drop across the Air Cooler. You can specify how the pressure drop across the Air Cooler is calculated in the Dynamic Specifications group. The Dynamic Parameters group contains information about the Dynamic Specifications Description Overall Delta P A set pressure drop is assumed across the valve operation with this specification. The flow and the pressure of either the inlet or exit stream must be specified or calculated from other operations in the flowsheet. The flow through the valve is not dependent on the pressure drop across the Air Cooler. To use the overall delta P as a dynamic specification, select the corresponding checkbox. The Air Cooler operations, like other dynamic unit operations, should use the k-value specification option as much as possible to simulate actual pressure flow relations in the plant. Overall k Value The k-value defines the relationship between the flow through the Air Cooler and the pressure of the surrounding streams. You can either specify the k-value or have it calculated from the stream conditions surrounding the Air Cooler. You can “size” the Cooler with a k-value by clicking the Calculate K button. Ensure that there is a non zero pressure drop across the Air Cooler before the Calculate K button is clicked. To use the k-value as a dynamic specification, select the corresponding checkbox. Pressure Flow Reference Flow The reference flow value results in a more linear relationship between flow and pressure drop. This is used to increase model stability during startup and shutdown where the flows are low. If the pressure flow option is chosen the k value is calculated based on two criteria. If the flow of the system is larger than the k Reference Flow the k value remains unchanged. It is recommended that the k reference flow is taken as 40% of steady state design flow for better pressure flow stability at low flow range. If the flow of the system is smaller than the k Reference Flow the k value is given by: where Factor is determined by HYSYS internally to take into consideration the flow and pressure drop relationship at low flow regions. kused kspecified Factor×=4-15 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-16 Air Cooler ww Thholdup of the Air Cooler, which is described in the table below. Holdup Page The Holdup page contains information regarding the properties, composition, and amount of the holdup. The Zone drop-down list enables you to select and view the holdup data for each zone in the operation. Stripchart Page The Stripchart page allows you to select and create default strip charts containing various variable associated to the operation. 4.1.8 HTFS - ACOL Tab This tab allows you to access certain ACOL functions. To access the functions on this tab, you must do the following: • Install and license ACOL6.4. • Select HTFS-Engines from the Air Cooler Model drop- down list on the Parameters page of the Design tab. The HTFS-Engines option runs only in Steady State mode. Dynamic Parameters Description Fluid Volume Specify the Air Cooler holdup volume. Mass Flow The mass flow of process stream through the Air Cooler is calculated. Exit Temperature The exit temperature of the process stream. The Air Cooler operation only has one zone. If you provide more data than is required, ACOL will perform consistency checks and warn you of any discrepancies. Refer to Section 1.3.3 - Holdup Page for more information. Refer to Zone Information section for more information. Refer to Section 1.3.7 - Stripchart Page/Tab for more information. For more information about ACOL data input, refer to the ACOL Reference Guide. Also, refer to the ACOL Online Help for information about specific input fields.4-16 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-17 ww ThACOL Simulation Modes ACOL has eight different simulation modes, four of which are recognized by HYSYS. Each mode calculates a different variable based on the data you supply. HYSYS checks the data entered for the air-cooler to determine if ACOL can run, then which mode ACOL will run based on the supplied data. HYSYS then sends the data to ACOL. The following tables list and describe the criteria used by HYSYS to determine the air cooler status messages, whether or not ACOL can run, and which mode ACOL will run. All simulation modes The following applies unless specified differently: ACOL Simulation 9 Calculation of the outlet temperature: Criteria Value Air inlet temperature specified Air outlet temperature not specified Pressure drop not specified Process inlet temperature specified Process outlet temperature not specified Criteria Value Process inlet temperature specified Process outlet temperature not specified Airflow specified Process flow rate specified4-17 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-18 Air Cooler ww ThACOL Simulation 1 Calculation of the inlet temperature: ACOL Simulation 3 Calculation of the process mass flow rate: ACOL Simulation 4 Calculation of the air mass flow rate: Importing and Exporting ACOL Input Files Import and Export buttons appear on every page of the HTFS- Criteria Value Process inlet temperature not specified Process outlet temperature specified Airflow specified Process flow rate specified Process inlet temperature not specified Process outlet temperature specified Criteria Value Process inlet temperature specified Process outlet temperature specified Airflow specified Process flow rate not specified Criteria Value Process inlet temperature specified Process outlet temperature specified Airflow not specified Process flow rate specified4-18 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-19 ww ThACOL tab. These buttons allow you to import existing ACOL data or export the current data. The file format used is ACOL Input files [*.aci]. Bundle Geometry Page The Bundle Geometry page content changes depending on the radio button you select. Headers/Nozzles Radio Button Figure 4.14-19 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-20 Air Cooler ww ThThe following table describes the fields that appear when you click the Headers/Nozzles radio button. Object Description Number of Inlet Nozzles Enter the number of inlet nozzles per bundle. Too few nozzles can cause excessive pressure losses and possibly erosion of the nozzles and headers. Default value is 1. Number of Outlet Nozzles Enter the number of outlet nozzles per bundle. If a phase change occurs through the bundle then it may be appropriate to have a different number of nozzles of different size to the inlet nozzles. Default value is 1. Inside Diameter of Inlet Nozzle Enter the inside diameter of the inlet nozzles. Defaults to the highest preferred diameter which gives a momentum flux (rV2) less than 6000 kg/m s2. Preferred sizes are; 50 mm, 100 mm, 150 mm, 200 mm, and so forth. Inside Diameter of Outlet Nozzle Enter the inside diameter of the outlet nozzles. Defaults to the highest preferred diameter which gives a momentum flux (rV2) less than 6000 kg/m s2. Preferred sizes are; 50 mm, 100 mm, 150 mm, 200 mm, and so forth. Type of Header Type of Header options: Box, D-header, Plug, Cover Plate, or Manifold. U-Bend Configuration U-Bend Configuration options: No-bends, U-bends in alternate passes, or U-bends in every pass. Depth of Inlet Header Enter the depth of the header at the tubeside fluid inlet. For a D-header, this will be the maximum depth of the D-section. Default is 300mm (11.8 in) for Air-cooled Heat Exchangers. Depth of Other Header Enter the depth of the other header. The other header is at the side opposite to the inlet header. For an odd number of passes, this will be the outlet header. For a D-header, the depth will be the maximum depth of the D-section. Default is 150mm (5.9 in) for Air-cooled Heat Exchangers. Perf. Pass Plates Enter the average number of velocity heads lost through each perforated plate in the headers. Perforated pass plates are usually fitted to strengthen the header in high-pressure applications. Default value is 0.04-20 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-21 ww ThBundle Radio Button The following table describes the fields that appear when you click the Bundle radio button. Figure 4.2 Object Description Number of Passes Required. Must be <= 50. With four or more number of passes, the exchanger tends towards the ideal of a pure counter current or co-current exchanger. Number of Rows Required. Must be <= 100. Number of Tubes Required. Must be < 1000. Type of Bundle There are five types of bundle layouts available from the drop-down list; the bundle layout affects the allowable number of tubes. NumberOfTubesInARow = NumberOfTubes/ NumberOfRows If the NumberOfTubesInARow does not have a remainder, then only these bundles can be used: • Inline • Staggered - even rows to the right • Staggered - even rows to the left If the NumberofTubesInARow has a remainder, then only two bundles can be used: • Staggered - extra tubes in odd rows • Staggered - extra tube in even rows Tube Side Flow Orientation Select the orientation of the tubeside flow with respect to the X-side flow. This item is used only to correctly set up a symmetrical bundle. It does not apply to a non-symmetrical bundle as the tubeside flow orientation is explicitly set when the bundle is defined using the Pass Layout Window. Select from Counter-current (default), Cross-flow, Co- current4-21 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-22 Air Cooler ww ThRows per Pass Enter the number of tube rows occupied by each tubeside pass. Only to be used when specifying symmetrical bundles. When specifying non- symmetrical bundles use the Pass Layout Window to specify the bundle. Max. No. Tubes per Row per Pass Enter the maximum number of tubes in each row occupied by each pass. Only to be used when specifying symmetrical bundles. When specifying non- symmetrical bundles use the interactive bundle specification feature. X-Side Stream Mass Flow Orientation Defines the X-side flow orientation relative to the Bundle direction. Enter 0 (vertical-up), 45, 90 (horizontal) or 180 (vertical-down). Default value is 0. Bundle Relative Direction Defines the angle of orientation of the bundle relative to the X-side Stream Mass Flow Direction (XSFD) in the range -90° to +90°. If 0° (default) is entered the tubes are always horizontal regardless of the X-side Stream Mass Flow Direction. Number of Circuits Enter the number of times a basic pass layout pattern appears in the bundle. The repeat facility is used when a basic pass layout pattern is to be repeated a number of times across the bundle. This feature is most likely to be of use in air- conditioning coils with U tube circuits. It may only be used: a) with inline bundles and staggered bundles with the same number of tubes per row or, b) when X-side stream inlet conditions do not vary across the bundle. When using the repeat facility, count the original section as 1 (Default). Shape of Tubes Select from Round (default), Oval, or Flat. If Oval or Flat tubes are selected, the geometric data for the tube should be entered for each tube type on the Non- circular Tubes page (click the Tubes radio button).The geometric data for each fin type can be entered on the Extended Surfaces page. Pass Layout Diagram button Displays a Pass Layout diagram that allows you to specify the pass arrangement according to your requirements. Object Description4-22 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-23 ww ThTubes Radio Button The following table lists and describes the fields that appear when you click the Tubes radio button. Figure 4.3 Object Description Common Options Add Tube button Adds a tube to the air cooler. Remove Tube button Removes a tube from the air cooler. Effective Length This is the length of tube that is transferring heat. Inactive parts of a tube are where it fits into the tubesheets and comes into contact with tube supports. Include these parts in the Total Tube Length. Default is 6000mm (19.7 ft) for Air-cooled Heat Exchangers. Total Length This is the total length of tube including the ends fitted into the tubesheets and where the tube comes into contact with tube supports.This is used for tubeside pressure drop calculations only. Default value is the Effective tube length. Transverse Pitch This is the distance between the centre-lines of consecutive tubes in the same tube row. Default is 2.3 times Tube OD for Air-cooled Heat Exchangers4-23 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-24 Air Cooler ww ThLongitudinal Pitch If you have a standard TEMA tube layout, for example triangular (30°), rotated square (45°), rotated triangular (60°), or square (90°), then use the layout angle. If you have a non-standard tube layout then use this item. The plain tube correlations are only valid for the standard TEMA tube layout given above so use layout angle in this case. For uncommonly large longitudinal pitches, you may have to allow for a reduction in the heat transfer coefficient separately from ACOL. Currently ACOL does not allow for this effect. There is no default value. The value will be calculated from the Transverse Pitch and the Layout Angle. Layout Angle Use this field to enter the layout angle for a standard TEMA tube layout. • 30° – triangular arrangement (default) • 45° – rotated square arrangement • 60° – rotated triangular arrangement • 90° – square arrangement (for in-line banks only) If you have a non-standard tube layout, in other words one, which would give a layout angle not in the above list then, input longitudinal pitch instead of this item. Use this item for plain tubes, as the correlations are only valid for the standard TEMA tube layouts. Default Value is 30°. Tube Details group options Tube Number Displays the system defined tube number. If you have more than one tube type defined, then corresponding input cells appear on the Extended Surfaces and Materials pages. Tube ID Up to 4 Tube Diameters may be specified. Default values for Tube ID(1): Tube ID(1) = Tube OD(1) – 3.3mm (0.13in) for Air-cooled Heat Exchangers. Other tube types default to Tube ID(1). Tube OD Up to 4 Tube Diameters may be specified. API661 recommends 25.4 mm or 1 inch as the minimum outside diameter. Non-Circular Tube Details group options Non-Circular Tubes checkbox Select this checkbox to specify non-circular tube parameters. When you click this checkbox, the fields listed below appear. Tube Number Displays the system defined tube number. Major Axis on Outside of Tube Allows you to specify the length of the flatter side of the tube. Object Description4-24 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-25 ww ThExtended Surfaces Page The following table lists and describes the objects on this page. Minor Axis on Outside of Tube Allows you to specify the length of ‘short’ side of the tube. Tube Wall Thickness Allows you to specify the tube wall thickness. Figure 4.4 Object Description Add Fin Click this button to add a fin. The fin parameter set appears in the Fin Details table. If you have finned tubes, you will need to supply tube and fin details on the Bundle Geometry and Extended Surfaces pages. Remove Fin Click this button to remove the select fin parameter set. Fin ID Displays the system generated Fin number. Fin Type Allows you to select a fin type from a drop-down list: • Integral • G-fin (embedded) (default) • Modified G-fin • L-finned • Bi-metallic or extruded • Shoulder-grooved • Tube-in-plate • Plain tubes • Serrated fins • Low fins • Circular studs • Rectangular studs • Elliptical studs • Lenticular studs • Chamfered studs Object Description4-25 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-26 Air Cooler ww ThTip Diameter or Plate Length For a finned or studded tube, enter the fin (or stud) tip diameter. Default is 2.25 times Tube OD for Air-cooled Heat Exchangers. For tube-in-plate fins, enter the plate length in the direction of the X-side flow (from the leading edge to the trailing edge of the plate). This will be calculated if left blank. Frequency This is the number of fins per unit length or the number of stud crowns per unit length. Default is 433 fins/m (11 fins/inch) for Air-cooled Heat Exchangers. Mean Fin Thickness For fins made by wrapping ribbon around the base tube, the fin thickness is usually thinner than the ribbon thickness. Default is 0.28mm (0.011in) for Air- cooled Heat Exchangers Fin Root Diameter Enter the root diameter for Integral, L-finned, Extruded tubes or Shoulder-grooved fins. For other fin types, the fin root diameter is the base tube outside diameter. The Common Fin Root Diameter applies to the whole bundle unless a local values is used. Defaults to the tube outside diameter. Number of Studs per Crown This is the number of studs making up a crown. Stud Width This item is not required for circular studs. Major Axis of Fin This is the length of the ‘long’ side of the tube. Default is 54 mm (2.13 in). Minor Axis of Fin This is the length of the ‘short’ side of the tube. Default value is 34 mm (1.34 in). Fin Root Thickness For L shape or bimetallic fins. Fin Root Thickness is used in place of Fin Root Diameter for round fins. Default value is 0.0. Object Description4-26 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-27 ww ThACHE Geometry Page The following table lists and describes some of the objects on the ACHE Geometry page. Figure 4.5 Object Description Number of Bays per Unit Required. Range 1-99. Default is 1. Number of Bundles per Bay Required. Range 1-12. Default is 1. Number of Fans per Bay Required. Range 1-6. Default is 2. Fan Configuration Select from Forced Draught, Induced Draught, or No fans. Type of Louvres Select the type of louvres required for the air cooler. Options appear in the image to the left. Louvre Angle or Loss Coefficient Enter either the louvre opening angle (for louvre types A-D) or the loss coefficient (for louvre type K). An angle of 0° is fully open and 90° is fully closed. Steam Coils Select Yes or No (default) depending on whether a steam coil is fitted. This item is used only in the calculation of the X-side pressure drop. Steam coils are assumed to consist of one row of tubes with the same tube geometry as the first type of fin but with twice the transverse pitch. Plenum Depth This is distance from the bundle side of the fan ring to the bundle. Defaults to 0.4 times the exchanger fan diameter.4-27 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-28 Air Cooler ww ThProcess Data Page HYSYS uses information in the first six fields to determine if ACOL can run, and what mode it will use. Ground Clearance This is the distance from the ground to the fan inlet for a forced draught exchanger or to the bundle entry for an induced draught exchanger. Defaults to1.5 times the exchanger fan diameter. Height Above Bundle This is the distance from the top of the bundle to the exchanger exit. Use only with the Natural Convection simulation option. The hardware height acts as a 'chimney' filled with hot air. For forced draught exchangers this will typically be the height of a wind skirt above the bundle. For induced draught exchangers it will be the distance to the top of the fan casing. Default value is 0.0. Exchanger Fan Diameter This is used to calculate fan related pressure losses and fan noise levels. The fan diameter cannot be larger than the bay width. Default calculated to give 40% bundle coverage per fan. A or V Frame The default is (None). Figure 4.6 You cannot edit the values in black text. These values are determined using input on other tabs in the Air Cooler property view. Object Description Refer to ACOL Simulation Modes section for more information.4-28 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-29 ww ThThe following table lists and describes the objects on this page. Object Description Process Steams group Total Mass Flow Displays the process stream mass flow calculated by HYSYS. Inlet Mass Quality Displays the default value. Outlet Mass Quality Displays the system defined outlet mass quality. Inlet Temperature Displays the stream inlet temperature as defined on the Worksheet tab. Outlet Temperature Displays the stream outlet temperature, if available. Inlet Pressure Displays the stream inlet pressure as defined on the Worksheet tab. Heat Load You may enter the heat load directly, or omit it and leave ACOL to calculate it from the stream flowrate and inlet and outlet conditions. ACOL will use the input heat load to calculate the duty ratio (heat load calculated/heat load input), otherwise it will use the input tubeside stream conditions. Fouling Resistance Allows you to specify the fouling resistance of the process stream. Air Stream Conditions group Inlet Dry Bulb Design Temperature This is the temperature of the incoming air; it has a significant effect on the overall heat transfer area required. This is a useful parameter for helping to determine Annual Fan Power Consumption. Inlet Gauge Pressure This is the gauge pressure of the air at entry to the bundle. This item is intended primarily for ducted systems where there may be a slight positive air inlet pressure. Negative values may also be used.The default air pressure is the International Standard Atmosphere at sea level, 1013mbar. Use either or both inlet gauge pressure and altitude to specify the actual inlet air pressure. Inlet Humidity Parameter Select the way in which the Inlet Humidity Value will be expressed: • Humidity ratio (default) • Relative humidity The only two-phase system that ACOL can handle on the X-side is the condensation of water vapour from a humid air stream. Important note: If you want to use this parameter, ensure that you have selected Humid Air for the X-side Option Inlet Humidity Value This is the value of the air inlet humidity in the way selected by the Inlet Humidity Parameter.4-29 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-30 Air Cooler ww ThWinter Des. Temperature for Fans Only This is the value for the X-side Stream Winter Inlet Temperature (or Minimum Ambient Temperature) and is used for calculating maximum fan power consumption only. Only relevant to forced draught exchangers. Default value is 0°C (32°F). Altitude This is the height of the unit above sea level. You can use either or both inlet gauge pressure and altitude to specify the actual inlet air pressure.The default air pressure is the International Standard Atmosphere at sea level, 1013mbar. Fouling Resistance Allows you to specify the fouling resistance of the air stream. X-Side Option This is the fluid you wish to use on the X-side. Select from Dry Air (default), Humid Air, or Dry Gas. Dry Air is appropriate for air-cooled heat exchangers and other heat exchangers where air is being heated. Dry Gas is appropriate for waste heat recovery units where gases such as flue gases are being cooled. Also for any exchanger where gases other than or including air are handled. ACOL cannot handle condensation of any of the components of the gas stream. Air Mass Flow Rate Allows you to specify the air mass flow rate for the air stream. You can also edit this value on the Rating tab. Solution Estimates - Optional group For ACOL to run, it must have initial values for this group. Only the estimate that applies to the current calculation will be used. Process Stream Flow Rate Estimate Provides an initial value for ACOL calculations. If you do not enter a value, the following estimates are used. When calculating the process mass flow rate: Process Mass Flow = 5kg/s When calculating the air mass flow rate: No estimate required Delta T Estimate Provides an initial value for ACOL calculations. If you do not enter a value, the following estimates are used. When calculating the outlet process temperature: Outlet Process temp = Inlet Process temp - 10°C When calculating the inlet process temperature: Inlet Process temp = Outlet Process temp + 10°C Object Description4-30 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-31 ww ThMaterials Page On this page you can define the tube, header and fin materials and material properties. The default material for tubes and headers is carbon steel; the default for fins is aluminium. Enhanced Surfaces Page This page changes depending on which radio button you select. • Specific Enhancements Radio Button Figure 4.7 Figure 4.84-31 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-32 Air Cooler ww ThThe following table lists and describes some of the objects available for the Specific Enhancements option. Object Description Enhancement Specification Select the type of enhancement specification from the drop-down list. Available options appear in the image to the left. Pass Number Enhancement Starts Enter the pass number from which (and including) the tube enhancement is to take effect. This allows you to specify tubeside enhancement where it might be most effective. Pass Number Enhancement Stops Enter the pass number at which (and including) the tube enhancement is to stop. If this item is left blank and tubeside enhancement has been specified, then the enhancement will stop at the last pass. Twisted Tape Thickness This is the thickness of the twisted tape insert. Default value is 0.5 mm (0.02 in). 180 Degree Twist Pitch This is the pitch of the twisted tape insert as it completes one 180-degree twist. Default value is 50 mm (2 in). Wet Wall Desuperheating Select YES for wet wall (or NO for dry wall) desuperheating. Wet wall desuperheating occurs when the bulk temperature of a stream is above the dew point, but the local wall temperature is below the dew point. If the wet wall calculation is selected, the program corrects the heat transfer rate in the desuperheating zone to allow for condensation occurring at the wall. When the alternative dry wall calculation is selected the program uses the single phase gas coefficient until the bulk vapour temperature reaches the dew point. As a rule, dry wall coefficients are usually lower than wet wall coefficients, and more conservative. Default is Yes Reynolds Number This field allows you to enter values of Reynolds Number for the first and second points which correspond with input values of tubeside heat transfer j factors and friction factors. The reference diameter is the tube inside diameter. A log-log interpolation is performed between two points. Extrapolation is not permitted. Heat Transfer J Factor This field allows you to enter values of the heat transfer j factor corresponding to the values of the Reynolds Number for Points 1 and 2. This is particularly useful for specifying the performance of tube inserts. A log-log interpolation is performed between two points. Extrapolation is not permitted. Friction Factor This field allows you to enter values of the friction factor corresponding to the values of the Reynolds Number for Points 1 and 2. This is particularly useful for specifying the performance of tube inserts. A log- log interpolation is performed between two points. Extrapolation is not permitted.4-32 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-33 ww Th• General Enhancements Radio Button The following table lists and describes some of the objects available for the General Enhancements option. Figure 4.9 Object Description Surface Identification group Add Surface button Adds another surface set to the matrix. Remove Surface button Removes a surface set from the matrix. Enhanced Surface Name Displays the system generated set name. Maximum number of surfaces = 20. Where Used Defines where the enhanced surface is used. Surface Performance Data group Set list Displays the list of available sets. Reynolds Number Allows you to specify the Reynolds Number for the selected set. You can enter up to four values. Friction Factor Allows you to specify the friction factor for the selected set. You can enter up to four values. Colburn J Factor Allows you to specify the Colburn J Factor for the selected set. You can enter up to four values.4-33 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-34 Air Cooler ww ThOptions Page This page determines what appears on the Results page. Figure 4.10 Object Description Main Output Options group Units of Output Determines the output data units. Choose from S.I., British/US, and Metric. Physical Properties Package Determines where the output data goes: line printer, separate file, or no output Detailed Table Output Determines the output table format. Lines per Page for Line Printer Output Sets the number of lines on a page for printed output. Units of Repeat Output Sets the units for repeated output on the Results page; contains the same options as Units of Output. Final Output Page Select Yes if you require the final output page in the lineprinter output. Header Output Select Yes to show headers in the lineprinter output. Temperature Table Select Yes to show the temperature table in the lineprinter output. Pressure Tables Select Yes to show the pressure tables in the lineprinter output. Monitor Output group Input Data Use the default setting. Representative Tube Details Use the default setting.4-34 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-35 ww ThResults Page This page displays the result of the ACOL calculations. Set the format of the Results page on the Options page. 4.1.9 HTFS+ - ACOL+ Tab By providing access to the ACOL+ Engine, HYSYS provides a detailed calculation for Air Cooler heat exchangers. To access the ACOL+ functions on the HTFS+-ACOL+ tab, you must first do the following: • Install and license ACOL+. • Select ACOL+ Design from the Air Cooler Model drop- down list on the Parameters page of the Design tab. The Monitor Output group is used for debugging purposes only. Use the default settings. Figure 4.11 If you provide more data than is required, ACOL+ will perform consistency checks and warn you of any discrepancies.4-35 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-36 Air Cooler ww ThImporting and Exporting ACOL+ Input Files Import and Export buttons appear on every page of the HTFS+-ACOL+ tab. These buttons allow you to import existing ACOL+ data or export the current data. The file format used is ACOL+ Input files [*.edr]. HTFS+ Results On each tab, key results are displayed. To view the full HTFS+ results, click the HTFS+ Results button. Bundle Geometry Page The Bundle Geometry page content changes depending on the radio button you select. The radio button options are: • Headers • Nozzles • Bundle • Tubes Headers Radio Button The following fields appear when you select the Headers radio button. • Header Type • U-Bend Configuration • Header side wall clearance • Header top wall clearance • Header bottom wall clearance • Depth • Wall thickness • Tubesheet thickness4-36 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-37 ww ThNozzles Radio Button The following fields appear when you select the Nozzles radio button. • Actual ID • Actual OD • Quantity • Orientation • Length • Flange thickness • Flange diameter • Nozzle flange rating • Nozzle flange type Bundle Radio Button The following fields appear when you select the Bundle radio button. • Number of Passes • Number of Rows • Number of Tubes • Type of Bundle • Flow Direction • Rows per Pass • Maximum Number of Tubes per Row per pass • Transverse Pitch • Longitudinal Pitch • Tube Layout Angle • Tube Support Number • Tube Support Width To specify the bundle geometry, click the Bundle Diagram button.4-37 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-38 Air Cooler ww ThTubes Radio Button The following fields appear when you select the Tubes radio button. • Number of Tubes • Tube Shape • Effective Length • Tube Length • Tube Material • Tube OD • Tube ID • Tube Wall Thickness Extended Surfaces Page The fields on the Extended Surfaces page depend on the radio button you select. The radio button options are: • Fins • Serrations/Studs Fins The following fields appear when you select the Fins radio button. • Fin Type • Fin Material • Fin Frequency • Fin Tip Diameter • Fin Thickness • Fin Root Diameter • Fin Root Thickness • Major Axis OD • Minor Axis OD • Major Axis Fin OD • Minor Axis Fin OD • HT Area Scaler • Last Row of Tubes4-38 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-39 ww ThSerrations/Studs The following fields appear when you select the Serrations/ Studs radio button. • Fin Type • Serration Width • Serration Length • Serration Fin Method • Number of studs per crown • Stud width ACHE Geometry Page The fields on the ACHE Geometry page depend on the radio button you select. The radio button options are: • Unit • Accessories/Clearance Unit The following fields appear when you select the Unit radio button. • Number of Bays per Unit • Bundles per Bay • Fans per Bay • Number of Sides Fan Draws Air from • Flow Direction • Frame Type • Angle of Outside Flow • Tube Side Flow Direction • Fan Configuration • Fan Inlet Type • Plenum Depth • Ground Clearance • Chimney Height above Bundle4-39 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-40 Air Cooler ww ThAccessories/Clearance The following fields appear when you select the Accessories/ Clearance radio button. • Louvre type • Louvre opening angle • Louvre pressure loss coef. • Louvre control • Steam coil • Width of sideframe • Sideframe to last tube row fin • Sideframe to 1st tube row fin • Distance between bundles within bays • Distance between bundles in adjacent bays • Angle of sideframe to horizontal • Bundle drainage angle Process Data Page The following fields appear on the Process Data page. • Process Streams group - Total Mass Flow - Inlet Mass Quality - Outlet Mass Quality - Inlet Temperature - Outlet Temperature - Inlet Pressure - Heat Load - Fouling Resistance • Air Stream Conditions group - Inlet Temperature - Outlet Temperature - Minimum Ambient Temperature - Altitude - Inlet Group Pressure - Allowable Pressure Drop - Fouling - Humidity Option - Humidity Ratio - Relative Humidity4-40 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-41 ww ThMaterials Page The following fields appear on the Materials page. • Tube Material • Header Material • Tubesheet Material • Tube Thermal Conductivity • Tube Density • Header Density • Fin Material • Fin Thermal Conductivity • Fin Material Density Enhanced Surfaces Page The fields on this page depend on which radio button you select: • Tube Side • Outside Tube Side The following fields appear when you select the Tube Side radio button. • Enhancement Type • Start Pass • End Pass • HTC Factor • Friction Factor • Twisted Tape Thickness • Twisted Tape Pitch • Reynolds Number • Colburn Factor • Friction Factor • Reynolds 1 • HT j Factor 1 • Friction Factor 1 • Reynolds 2 • HT j Factor 2 • Friction Factor 2 4-41 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-42 Air Cooler ww ThOutside The following fields appear when you select the Outside radio button. • Enhancement Type • Perf. DB Used • Pt. 1 Flow Parameter • Pt. 1 Ho Parameter • Pt. 1 DP Parameter • Pt. 2 Flow Parameter • Pt. 2 Ho Parameter • Pt. 2 DP Parameter • Ho Curve Coeff. • Ho Curve Exp. • DP Curve Coeff. • DP Curve Exp. • Ho Scaling Factor Options Page The following fields appear on the Options page. • Outside Vapor HTC • Tubeside Vapor HTC • Tubeside 2 phases HTC • Tubeside liquid HTC • Calculation steps • Number of iterations • Detailed calculation accuracy % • Main iteration accuracy % • Wet wall desuperheating option • Tube side flow distribution • Velocity heads • Highfin tube calculation • Low Fin Method • Outside Radiation HT • Exit pressure recovery coef. • Fan guard pressure loss coef. • Fan guard support pressure loss coef.4-42 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-43 ww ThStructures Page The following fields appear on the Structure page. • Bays share support legs • Number of support legs • Leg width in the X dir. • Leg width in the Z dir. • Ratio fan height to fan diameter • Tubesheet to sup. leg clearances • Sideframe to sup. leg clearance • Walkway thickness • Header walkway width • Header floor to bottom distance • Header offset from the headers • Bay walkway width • Bay offset from expected position • Fan walkway width • Fan offset from fan centerlines • Fan length beyond centers • Walkway railing height • Walkway railing post spacing • Walkway distance below fan rings Fans Page The fields on the Fans page depend on which radio button you select. The radio button options are: • Fans/Plenum • Motor Fans/Plenum The following fields appear when you select the Fans/Plenum radio button. • Fan Configuration • Fan Inlet Type • Fan Drive Type • Fan Pit Control • Fan Speed4-43 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-44 Air Cooler ww Th• Fan Drive Efficiency • Fan Static Efficiency • Plenum Type • Plenum Wall to Fan Diameter Ratio • Plenum Depth to Fan Diameter Ratio • Fan Ring Length to Fan Diameter Ratio • Position of Fan Ring to Length Ratio • Plenum to Bundle Frame X Clearance • Plenum to Tubesheet Z Clearance • Fan Entry Lip Width • Fan Center offset Motor The following fields appear when you select the Motor radio button. • Vertical distance from fan motor to fan center • Radial distance from fan motor shaft end to fan center • Fan Motor Body Length • Fan Motor Body Diameter • Fan Motor Shaft Length • Fan Motor Shaft Diameter • Length of motor section nearest shaft/motor length • Diameter of motor section nearest shaft/motor diameter • Corner radius of near motor section/motor length • Length of far motor section/motor length • Diameter of far motor section/motor diameter • Angle in XZ plane of all but last fan motor • Angle in XZ plane of the last fan motor4-44 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-45 ww Th4.2 Cooler/Heater The Cooler and Heater operations are one-sided heat exchangers. The inlet stream is cooled (or heated) to the required outlet conditions, and the energy stream absorbs (or provides) the enthalpy difference between the two streams. These operations are useful when you are interested only in how much energy is required to cool or heat a process stream with a utility, but you are not interested in the conditions of the utility itself. 4.2.1 Theory Steady State The primary difference between a cooler and a heater is the sign convention. You specify the absolute energy flow of the utility stream, and HYSYS then applies that value as follows: • For a Cooler, the enthalpy or heat flow of the energy stream is subtracted from that of the inlet stream: • For a Heater, the heat flow of the energy stream is added: The difference between the Cooler and Heater is the energy balance sign convention. The Cooler and Heater use the same basic equation. Heat Flowinlet - Dutycooler = Heat Flowoutlet (4.12) Heat Flowinlet + Dutycooler = Heat Flowoutlet (4.13)4-45 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-46 Cooler/Heater ww ThDynamic The Cooler duty is subtracted from the process holdup while the Heater duty is added to the process holdup. For a Cooler, the enthalpy or heat flow of the energy stream is removed from the Cooler process side holdup: For a Heater, the enthalpy or heat flow of the energy stream is added to the Heater process side holdup: where: M = process fluid flow rate = density H = enthalpy Qcooler = cooler duty Qheater = heater duty V = volume shell or tube holdup Pressure Drop The pressure drop of the Cooler/Heater can be determined in one of two ways: • Specify the pressure drop manually. • Define a pressure flow relation in the Cooler or Heater by specifying a k-value. If the pressure flow option is chosen for pressure drop determination in the Cooler or Heater, a k value is used to relate the frictional pressure loss and flow through the Cooler/Heater. (4.14) (4.15) M Hin Hout–( ) Qcooler– ρ d VHout( ) dt ----------------------= M Hin Hout–( ) Qheater+ ρ d VHout( ) dt ----------------------= ρ 4-46 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-47 ww ThThe relation is similar to the general valve equation: This general flow equation uses the pressure drop across the heat exchanger without any static head contributions. The quantity, P1 - P2, is defined as the frictional pressure loss which is used to “size” the Cooler or Heater with a k-value. Dynamic Specifications In general, two specifications are required by HYSYS in order for the Cooler/Heater unit operation to fully solve in Dynamic mode: 4.2.2 Heater or Cooler Propety View There are two ways that you can add a Heater or Cooler to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Heat Transfer Equipment radio button. (4.16) Dynamic Specifications Description Duty Calculation The duty applied to the Cooler/Heater can be calculated using one of three different models: • Supplied Duty • Product Temp Spec • Duty Fluid Specify the duty model in the Model Details group on the Specs page of the Dynamics tab. Pressure Drop Either specify an Overall Delta P or an Overall K-value. Specify the Pressure Drop calculation in the Dynamic Specifications group on the Specs page of the Dynamics tab. flow density k× P1 P2–=4-47 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-48 Cooler/Heater ww Th3. From the list of available unit operations, select Cooler or Heater. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the Cooler icon or the Heater icon. The Cooler or Heater property view appears. 4.2.3 Design Tab The Design tab contains the following pages: • Connections • Parameters • User Variables • Notes Figure 4.12 Cooler icon Heater icon4-48 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-49 ww ThConnections Page The Connections page is used to define all of the connections to the Cooler/Heater. You can specify the inlet, outlet, and energy streams attached to the operation on this page. The name of the operation can be changed in the Name field. Parameters Page The applicable parameters are the pressure drop (Delta P) across the process side, and the duty of the energy stream. Both the pressure drop and energy flow can be specified directly or can be determined from the attached streams. Figure 4.13 Figure 4.144-49 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-50 Cooler/Heater ww ThYou can specify a negative duty value, however, be aware of the following: • For a Cooler, a negative duty means that the unit is heating the inlet stream. • For a Heater, a negative duty means that the unit is cooling the inlet stream. User Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor that allows you to record any comments or information regarding the specific unit operation, or the simulation case in general. 4.2.4 Rating Tab You must specify the rating information only when working with a dynamics simulation. Nozzles Page On the Nozzles page, you can specify nozzle parameters on both the inlet and outlet streams connected to a Cooler or Heater. The addition of nozzles to Coolers and Heaters is relevant when creating dynamic simulations. HYSYS uses the proper sign convention for the unit you have chosen, so you can enter a positive duty value for both heater and cooler. For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab. Refer to Section 1.3.6 - Nozzles Page for more information.4-50 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-51 ww ThHeat Loss Page Rating information regarding heat loss is relevant only in Dynamic mode. The Heat Loss page contains heat loss parameters that characterize the amount of heat lost across the vessel wall. In the Heat Loss Model group, you can choose either a Simple or Detailed heat loss model or no heat loss through the vessel walls. Simple Model The Simple model allows you to either specify the heat loss directly, or have the heat loss calculated from the specified values: • Overall U value • Ambient Temperature The heat transfer area, A, and the fluid temperature, Tf, are calculated by HYSYS using the following equation: For a Cooler, the parameters available for the Simple model appear in the figure below. Q = UA(Tf - Tamb) (4.17) Figure 4.154-51 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-52 Cooler/Heater ww ThThe simple heat loss parameters are as follows: • Overall Heat Transfer Coefficient • Ambient Temperature • Overall Heat Transfer Area • Heat Flow The heat flow is calculated as follows: where: U = overall heat transfer coefficient A = heat transfer area TAmb = ambient temperature T = holdup temperature Heat flow is defined as the heat flowing into the vessel. The heat transfer area is calculated from the vessel geometry. The ambient temperature, TAmb, and overall heat transfer coefficient, U, can be modified from their default values shown in red. Detailed Model The Detailed model allows you to specify more detailed heat transfer parameters. 4.2.5 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the unit operation. Heat Flow = UA(TAmb - T) (4.18) The HYSYS Dynamics license is required to use the Detailed Heat Loss model. The PF Specs page is relevant to dynamics cases only. Refer to Section 1.6.1 - Detailed Heat Model in the HYSYS Dynamic Modeling guide for more information. Refer to Section 1.3.10 - Worksheet Tab for more information.4-52 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-53 ww Th4.2.6 Performance Tab The Performance tab contains pages that display calculated stream information. By default, the performance parameters include the following stream properties: • Pressure • Temperature • Vapour Fraction • Enthalpy Other stream properties can be viewed by adding them to the Viewing Variables group on the Setup page. All information appearing on the Performance tab is read-only. The Performance tab contains the following pages: • Profiles • Plots • Tables • Setup Profiles Page In Steady State mode, HYSYS calculates the zone conditions for the inlet zone only, regardless of the number of zones specified. Figure 4.164-53 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-54 Cooler/Heater ww ThPlots Page On the Plots page, you can graph any of the default performance parameters to view changes that occur across the operation. All default performance parameters are listed in the X Variable and Y Variable drop-down lists below the graph. Select the axis and variables you want to compare, and the plot is displayed. To graph other variables, you need to go to the Setup page and add them to the Selected Viewing Variables group from the Available Variables listed. A temperature - pressure graph for a Cooler, with 5 specified intervals is displayed in the figure below. In Steady State mode, stream property readings are taken only from the inlet and outlet streams for the plots. As such, the resulting graph is always a straight line. The property values are not calculated incrementally through the operation. You can right-click on the graph area to access the graph controls and manipulate the graph appearance. Figure 4.17 Refer to Section 1.3.1 - Graph Control Property View for more information. You can specify the number of calculation intervals you want calculated across the graph in the Interval field. This divides the plot line into equally spaced intervals with the values displayed as described on the Tables page.4-54 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-55 ww ThTables Page The Tables page displays the results of the Cooler/Heater in a tabular format. All default values for the pressure, temperature, vapour fraction, and enthalpy calculated for each interval are listed here. Figure 4.18 Information on the Tables page is read-only, except the Intervals value. You can specify the number of calculation intervals you want calculated across the data in the Interval field. This divides the data up into equally spaced intervals. You can select what phase options to view by clicking on the checkbox. For some options you need to add variables via the Setup page.4-55 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-56 Cooler/Heater ww ThSetup Page The Setup page allows you to filter and add variables to be viewed on the Plots and Tables pages. The variables that are listed in the Selected Viewing Variables group are available in the X and Y drop down list for plotting on the Plots page. The variables are also available for tabular plot results on the Tables page based on the Phase Viewing Options selected. 4.2.7 Dynamics Tab In the Dynamic mode, the values you enter in the Dynamics tab affects the calculation. The Dynamics tab contains the following pages: • Specs • Duty Fluid • Holdup • Stripchart Figure 4.19 If you are working exclusively in Steady State mode, you do not need to change any of the values on the pages accessible on the Dynamics tab.4-56 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-57 ww ThSpecs Page The Specs page contains information regarding the calculation of pressure drop across the Cooler or Heater: Zone Information HYSYS has the ability to partition heat transfer opera6tions into discrete sections called zones. By dividing the unit operation into zones, you can make different heat transfer specifications for individual zones, and therefore more accurately model the physical process. Specifying the Cooler/Heater with one zone provides optimal speed conditions, and is usually sufficient in modeling accurate exit stream conditions. Model Details The Model Details group must be completed before the simulation case solves. The number of zones and the volume of a Cooler/Heater can be specified in this group. Figure 4.204-57 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-58 Cooler/Heater ww ThHYSYS can calculate the duty applied to the holdup fluid using one of the three different methods described in the table below. Dynamic Specifications The Dynamic Specifications group allows you to specify how the pressure drop is calculated across the Cooler or Heater unit operation. The table below describes the specifications. Model Description Supplied Duty If you select the Supplied Duty radio button, you must specify the duty applied to the Cooler/Heater. It is recommended that the duty supplied to the unit operation be calculated from a PID Controller or a Spreadsheet operation that can account for zero flow conditions. Product Temp Spec If you select the Product Temp Spec radio button, you must specify the desired exit temperature. HYSYS back calculates the required duty to achieve the specified desired temperature. This method does not run as fast as the Supplied Duty model. Duty Fluid If you select the Duty Fluid radio button, you can model a simple utility fluid to heat or cool your process stream. The following parameters must be specified for the utility fluid on the Duty Fluid page of the Dynamics tab: • Mass Flow • Holdup Mass • Mass Cp • Inlet temperature • Average UA Specification Description Overall Delta P A set pressure drop is assumed across the Cooler or Heater operation with this specification. The flow and the pressure of either the inlet or exit stream must be specified, or calculated from other unit operations in the flowsheet. The flow through the valve is not dependent on the pressure drop across the Cooler or Heater. To use the overall delta P as a dynamic specification, select the corresponding checkbox in the Dynamic Specifications group Overall k Value The k-value defines the relationship between the flow through Cooler or Heater and the pressure of the surrounding streams. You can either specify the k-value, or have it calculated from the stream conditions surrounding the unit operation. You can “size” the Cooler or Heater with a k-value by clicking the Calculate k button. Ensure that there is a non zero pressure drop across the Cooler or Heater before the Calculate k button is clicked. To use the k- value as a dynamic specification, select the corresponding checkbox in the Dynamic Specifications group.4-58 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-59 ww ThZone Dynamic Specifications If the Cooler or Heater operation is specified with multiple zones, you can click the Spec Zones button to define dynamic specifications for each zone. In the Delta P Specs and Duties group, you can specify the following parameters: The Cooler or Heater unit operation, like other dynamic unit operations, should use the k-value specification option as much as possible to simulate actual pressure flow relations in the plant. Figure 4.21 Dynamic Specification Description dP Value Allows you to specify the fixed pressure drop value. dP Option Allows you to either specify or calculate the pressure drop across the Cooler or Heater. Specify the dP Option with one of the following options: • user specified. The pressure drop across the zone is specified by you in the dP Value field. • non specified. Pressure drop across the zone is calculated from a pressure flow relationship. You must specify a k-value, and activate the specification for the zone in the Zone Conductance Specifications group. Duty A fixed duty can be specified across each zone in the Cooler or Heater unit operation.4-59 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-60 Cooler/Heater ww ThIn the Zone Conductance Specifications group, you can specify the following parameters: Duty Fluid Page The Duty Fluid page becomes visible if the Duty Fluid radio button is selected on the Specs page. The Duty Fluid page allows you to enter the following parameters to define your duty fluid: • Mass Flow • Holdup mass • Mass Cp • Inlet Temperature • Average UA The Counter Flow checkbox allows you to specify the direction of flow for the duty fluid. When the checkbox is active, you are using a counter flow. Dynamic Specification Description k The k-value for individual zones can be specified in this field. You can either specify the k-value, or have it calculated by clicking the Calculate k button Specification Activate the specification if the k-value is to be used to calculate pressure across the zone. Figure 4.224-60 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-61 ww ThThe View Zones button displays the duty fluid parameters for each of the zones specified on the Specs page. Holdup Page The Holdup page contains information regarding the Cooler or Heater holdup properties, composition, and amount. The Individual Zone Holdups group contains detailed holdup properties for each holdup in the Cooler or Heater. In order to view the advanced properties for individual holdups, you must first choose the individual zone in the Zone drop-down list. Stripchart Page The Stripchart page allows you to select and create default strip charts containing various variable associated to the operation. Figure 4.23 Refer to Section 1.3.3 - Holdup Page for more information. Refer to Section 1.3.7 - Stripchart Page/Tab for more information.4-61 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-62 Fired Heater (Furnace) ww Th4.3 Fired Heater (Furnace) The dynamic Fired Heater (Furnace) operation performs energy and material balances to model a direct Fired Heater type furnace. This type of equipment requires a large amount of heat input. Heat is generated by the combustion of fuel and transferred to process streams. A simplified schematic of a direct Fired Heater is illustrated in the figure below. In general, a Fired Heater can be divided into three zones: • Radiant zone • Convective zone • Economizer zone Figure 4.24 The Fired Heater operation is available as a dynamic unit operation only.4-62 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-63 ww ThThe Fired Heater operation allows multiple stream connections at tube side in each zone and optional economizer, and convection zone selections. The operation incorporates a single burner model, and a single feed inlet and outlet on the flue gas side. The following are some of the major features of the dynamic Fired Heater operation: • Flexible connection of process fluid associated in each Fired Heater zone. For example, radiant zone, convective zone, or economizer zone. Different Fired Heater configurations can be modeled or customized using tee, mixer, and heat exchanger unit operations. • A pressure-flow specification option on each side and pass realistically models flow through Fired Heater operation according to the pressure gradient in the entire pressure network of the plant. Possible flow reversal situations can therefore be modeled. • A comprehensive heat calculation inclusive of radiant, convective, and conduction heat transfer on radiant zone enables the prediction of process fluid temperature, Fired Heater wall temperature, and flue gas temperature. • A dynamic model which accounts for energy and material holdups in each zone. Heat transfer in each zone depends on the flue gas properties, tube and Fired Heater wall properties, surface properties of metal, heat loss to the ambient, and the process stream physical properties. • A combustion model which accounts for imperfect mixing of fuel, and allows automatic flame ignition or extinguished based on the oxygen availability in the fuel air mixture. To define the number of zones required by the Fired Heater, enter the number in #External Passes field on Connections page of the Design tab.4-63 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-64 Fired Heater (Furnace) ww Th4.3.1 Theory Combustion Reaction The combustion reaction in the burner model of the Fired Heater performs pure hydrocarbon (CxHy) combustion calculations only. The extent of the combustion depends on the availability of oxygen which is usually governed by the air to fuel ratio. Air to fuel ratio (AF) is defined as follows: You can set the combustion boundaries, such as the maximum AF and the minimum AF, to control the burner flame. The flame cannot light if the calculated air to fuel ratio falls below the specified minimum air to fuel ratio. The minimum air to fuel ratio and the maximum air to fuel ratio can be found on the Parameters page of the Design tab. The heat released by the combustion process is the product of molar flowrate, and the heat of formation of the products minus the heat of formation of the reactants at combustion temperature and pressure. In the Fired Heater unit operation, a traditional reaction set for the combustion reactions is not required. You can choose the fuels components (the hydrocarbons and hydrogen) to be considered in the combustion reaction. You can see the mixing efficiency of each fuel component on the Parameter page of the Design tab. (4.19) AF Mass of flow O2 Σ Mass flow of fuel ---------------------------------------------------⎝ ⎠ ⎛ ⎞ Mass Ratio of O2 in Air ---------------------------------------------------------------=4-64 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-65 ww ThHeat Transfer The Fired Heater heat transfer calculations are based on energy balances for each zone. The shell side of the Fired Heater contains five holdups: • three in the radiant zone • a convective zone • an economizer zone holdup as outlined previously in Figure 4.24. For the tube side, each individual stream passing through the respective zones is considered as a single holdup. Major heat terms underlying the Fired Heater model are illustrated in the figure below. Figure 4.254-65 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-66 Fired Heater (Furnace) ww ThThe heat terms related to the tubeside are illustrated in the figure below. Taking Radiant zone as an envelope, the following energy balance equation applies: where: = energy accumulation in radiant zone holdup shell side Figure 4.26 (4.20) d MradHrad( ) dt -------------------------------- d MRPFTubeHRPFTube( ) dt ---------------------------------------------------------+ MRPFHRPF( )IN MRPFHRPF( )OUT– MFGHFG( )IN MFGHFG( )OUT– QRadToCTube– Qrad wall sur– Qcon wall sur– Qrad wall to tube Qcon to wall– Qreaction + + + = d MradHrad( ) dt --------------------------------4-66 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-67 ww Th = energy accumulation in radiant zone process fluid holdup (tube side) (MRPFHRPF)IN = total heat flow of process fluid entering radiant zone tube (MRPFHRPF)OUT = total heat flow of process fluid exiting radiant zone tube (MFGHFG)IN = total heat flow of fuel gas entering radiant zone (MFGHFG)OUT = total heat flow of fuel gas exiting radiant zone QRadToCTube = radiant heat of radiant zone to convective zone’s tube bank Qrad_wall_sur = radiant heat loss of Fired Heater wall in radiant zone to surrounding Qcon_wall_sur = convective heat loss of Fired Heater wall in radiant zone to surrounding Qrad_wall_to_tube = radiant heat from inner Fired Heater wall to radiant zone’s tube bank Qrad_flame_wall = radiant heat from flue gas flame to inner Fired Heater wall Qcon_to_wall = convective heat from flue gas to Fired Heater inner wall Qreaction = heat of combustion of the flue gas Radiant Heat Transfer For a hot object in a large room, the radiant energy emitted is given as: where: = Stefan-Boltzmann constant, 5.669x10-8 W/m2K4 = emissivity, (0-1), dimensionless A = area exposed to radiant heat transfer, m2 (4.21) d MRPFTubeHRPFTube( ) dt --------------------------------------------------------- Qradiative δAε T1 4 T2 4–( )= δ ε 4-67 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-68 Fired Heater (Furnace) ww ThT1 = temperature of hot surface 1, K T2 = temperature of hot surface 2, K Convective Heat Transfer The convective heat transfer taking part between a fluid and a metal is given in the following: where: U = overall heat transfer coefficient, W/m2K A = area exposed to convective heat transfer, m2 T1 = temperature of hot surface 1,K T2 = temperature of surface 2, K The U actually varies with flow according to the following flow-U relationship if this Flow Scaled method is used: where: Uspecified = U value at steady state design conditions. The ratio of mass flow at time t to reference mass flow is also known as flow scaled factor. The minimum flow scaled factor is the lowest value, which the ratio is anticipated at low flow region. For the Fired Heater operation, the minimum flow scaled factor can be expressed only as a positive value. (4.22) (4.23) Qconvective UA T1 T2–( )= Uused Uspecified Mass flow at time t Reference Mass flow -------------------------------------------------------⎝ ⎠ ⎛ ⎞ 0.8 = 4-68 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-69 ww ThFor example, if the minimum flow scaled factor is +0.001 (0.1%), when this mass flow ratio is achieved, the Uused stays as a constant value. Therefore, Conductive Heat Transfer Conductive heat transfer in a solid surface is given as: where: k = thermal conductivity of the solid material, W/mK = thickness of the solid material, m A = area exposed to conductive heat transfer, m2 T1 = temperature of inner solid surface 1, K T2 = temperature of outer solid surface 2, K Pressure Drop The pressure drop across any pass in the Fired Heater unit operation can be determined in one of two ways: • Specify the pressure drop - delta P. • Define a pressure flow relation for each pass by specifying a k-value If the pressure flow option is chosen for pressure drop determination in the Fired Heater pass, a k value is used to relate the frictional pressure drop and molar flow, F through the Fired Heater. This relation is similar to the general valve equation: (4.24) (4.25) (4.26) Uused Uspecified 0.001( )0.8= Qconductive kA– T1 T2–( ) Δt ---------------------= Δt F k ρ P1 P2–( )=4-69 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-70 Fired Heater (Furnace) ww ThThis general flow equation uses the pressure drop across the Fired Heater pass without any static head contribution. The quantity, (P1-P2) is defined as the frictional pressure loss which is used to “size” the flow. The k value is calculated based on two criteria: • If the flow of the system is larger than the value at kref (k reference flow), the k value remain unchanged. It is recommended that the k reference flow is taken as 40% of steady state design flow for better pressure flow stability at low flow range. • If the flow of the system is smaller than the kref, the k value is given by: where: Factor = value is determined by HYSYS internally to take into consideration the flow and pressure drop relationship for low flow regions. The effect of kref is to increase the stability by modeling a more linear relationship between flow and pressure. This is also more realistic at low flows. Dynamic Specifications The following is a list of the minimum specifications required for the Fired Heater operation to solve: (4.27) Dynamic Specifications Description Connections At least one radiant zone inlet stream and the respective outlet zone, one burner fuel/air feed stream and one combustion product stream must be defined. There is a minimum of one inlet stream and one outlet stream required per zone. Complete the connections group for each zone of the Design tab. (Zone) Sizing The dimensions of the tube and shell in each zone in the Fired Heater must be specified. All information in the Sizing page of the Rating tab must be completed. kused kuser specified Factor×=4-70 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-71 ww Th4.3.2 Fired Heater Property View There are two ways that you can add a Fired Heater to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Heat Transfer Equipment radio button. 3. From the list of available unit operations, select Fired Heater. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the Fired Heater icon. Heat Transfer For each zone, almost all parameters in the Radiant Zone Properties group and Radiant/Convective/ Economizer Tube Properties groups are required except the Inner/Outer Scaled HX Coefficient. Nozzle Nozzle elevation is defaulted to 0. Elevation input is required when static head contribution option in Integrator property view is selected. Pressure Drop Either specify an overall delta P or an overall K value for the Fired Heater. Specify the pressure drop calculation method on the Tube Side PF page and Flue Gas PF page of the Dynamics tab. Dynamic Specifications Description Fired Heater icon4-71 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-72 Fired Heater (Furnace) ww ThThe Fired Heater property view appears. 4.3.3 Design Tab The Design tab contains the following pages: • Connections • Parameters • User Variables • Notes Figure 4.274-72 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-73 ww ThConnections Page On the Connections page, you can specify the name of the operation, and inlet and outlet streams. Figure 4.28 Object Description Econ Zone Inlet/ Outlet You can specify multiple inlet and outlet streams for the Economizer zone. Conv Zone Inlet/ Outlet You can specify multiple inlet and outlet streams for the Convective zone. Radiant Zone Inlet/ Outlet You can specify multiple inlet and outlet streams for the Radiant zone. Burner Fuel/Air Feed Specifies the stream to be used for the burner fuel. Combustion Product The stream that contains the products from the combustion. # External Passes You can define the number of zones required by the Fired Heater4-73 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-74 Fired Heater (Furnace) ww ThParameters Page The Parameters page is used to specify the Fired Heater combustion options. This page is divided into four groups. The Flame Status group, along with displaying the flame status, allows you to toggle between a lit flame and an extinguished flame. The Oxygen group simply allows you to specify the oxygen mixing efficiency. The Combustion Boundaries group is used to set the combustion boundary based on a range of air fuel ratios. The checkbox, when active, allows you to auto-light the flame if your calculated air fuel ratio is within the boundary. Finally the Fuels group allows you to select the components present in your fuel as well as set their mixing efficiencies. User Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Figure 4.29 For more information refer to Section 1.3.8 - User Variables Page/ Tab.4-74 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-75 ww ThNotes Page The Notes page provides a text editor that allows you to record any comments or information regarding the specific unit operation, or the simulation case in general. 4.3.4 Rating Tab The Rating tab contains the following pages: • Sizing • Nozzles • Heat Transfer Each page is discussed in the following sections. Sizing Page On the Sizing page, you can specify the geometry of the radiant, convective, and economizer zones in the Fired Heater. Figure 4.30 For more information, refer to Section 1.3.5 - Notes Page/Tab.4-75 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-76 Fired Heater (Furnace) ww ThFrom the Zone group on the Sizing page, you can choose between Radiative, Convective, and Economizer zone property views by selecting the appropriate radio button. These property views contain information regarding the tube and shell properties. To edit or enter parameters within these property views, click the individual cell and make the necessary changes. The figure below shows an example of the Fired Heater setup with one radiant zone/firebox only with four tube passes. This is the simplest type. Figure 4.314-76 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-77 ww ThThe figure below shows an example of the Fired Heater setup with a radiant, convective and economizer section. Tube Properties Group The Tube Properties group displays the following information regarding the dimension of the tube: • stream pass • tube inner diameter, Din • tube outer diameter, Dout • tube thickness • # tubes per external pass • tube length, L • tube inner area • tube outer area • tube inner volume A pass in the Fired Heater is defined as a path where the process fluid flows through a distinctive inlet nozzle and outlet nozzle. Figure 4.324-77 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-78 Fired Heater (Furnace) ww ThThe figure below illustrates the various dimensions of the tube and shell. Shell Properties Group The Shell Properties group displays the following information regarding the dimension of the shell: • shell inner diameter, Dsin • shell outer diameter, Dsout • wall thickness, ts • zone height, H • shell inner area • shell outer area • shell net volume Figure 4.334-78 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-79 ww Th• shell total volume Nozzles Page The information provided in the Nozzles page is applicable only in Dynamic mode. You can define the base elevation to ground level of the Fired Heater in the Nozzles page. Heat Transfer Page The information provided in the Heat Loss page is applicable only in Dynamic mode. This page displays the radiant heat transfer properties, heat transfer coefficients of the Fired Heater wall and tube, and shell area, tube area, and volume in each individual zone. HYSYS accounts for the convective, conduction, and radiative heat transfer in the radiant zone. For the convective heat transfer calculation, you have two options: • User Specified. You can specify the heat transfer coefficient of the inner tube and the outer tube. Figure 4.34 Figure 4.354-79 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-80 Fired Heater (Furnace) ww Th• Flow Scaled. The heat transfer coefficient is scaled based on a specified flow. The scaled heat transfer coefficient is defined by Equation (4.23). The same equation applies to the outer tube heat transfer coefficient calculation. Currently, the heat transfer coefficient U must be specified by the user. HYSYS calculates the heat transfer coefficient from the geometry/configuration of the Fired Heater. The radiant box or the fire box is assumed cylindrical in geometry. Radiant Zone Properties Group The following table describes each the parameters listed in the Radiant Zone group. The Radiant, Convective, and Economizer Tube Properties groups all contain similar parameters, which are described in the following table. Radiant Zone Parameter Description Zone to Wall Emissivity Emissivity of flue gas. HYSYS uses a constant value. Zone to Wall U Convective heat transfer coefficient of the radiative zone to the Fired Heater inner wall. Outer Wall to Surrounding Emissivity Emissivity of the Fired Heater outer wall. Outer Wall to Surroundings U Convective heat transfer coefficient of the Fired Heater outer wall to ambient. Furnace Wall Conductivity/ Specific Heat/Wall Density These are user specified properties of a single layer of Fired Heater wall. Tube Properties Description Zone to Tube Emissivity Emissivity of flue gas at radiant/convective zone to the tube in radiant/convective zone respectively. Wall to Tube Emissivity Radiant zone Fired Heater wall emissivity to the radiant zone tubes.4-80 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-81 ww ThIn general the Tube to Fluid HX Coefficient is always shown in a common Fired Heater flowsheet, however, the Zone to Wall U and Outer Wall to Surroundings U are usually unknown. The Outer wall to Surroundings U can be easily estimated from the Fired Heater convective heat loss calculation, Equation (4.22) if the total heat loss via Fired Heater wall is known. The total heat loss is normally expressed as a percentage of total Fired Heater duty. A 3-5% heat loss is an acceptable estimate. Inner HX Coeff Method There are two options to calculate the Heat transfer coefficient in the tube: User Specified or Flow Scaled. Flow Scaled provides a more realistic HX calculation where: Tube to Fluid HX Coefficient Heat transfer coefficient of the tube to the process fluid. Tube to Fluid HX Reference Flow Mass flow at which the tube to fluid HX coefficient is based on. Usually the ideal steady state flow is recommended as input. Tube to Fluid HX Minimum Scale Factor The ratio of mass flow of the process fluid to the reference mass flow in the tube. The valve ranges from a value of zero to one. If the process flow in the tube becomes less than the scale factor, the heat transfer coefficient used is smaller than U specified. Inner Scaled HX Coefficient The HX coefficient obtained if the Flow Scaled (Uused) method is applied to perform the calculation. Tube Cp, Density, Conductivity Metal properties of the tube in their respective zones. Outer HX Coefficient Method Method used to calculate the shell side HX coefficient. Two options available: User Specified or Flow Scaled. Zone to Tube HX Coefficient HX coefficient in the radiative/convective/ economizer or flue gas zones to the respective tubes. Zone to Tube HX Reference Flow Mass flow of the flue gas at which the outer HX coefficient is based upon. This is usually designed using the ideal steady state flow of the flue gas. Zone to Tube HX Minimum Scale Factor Mass ratio of flue gas flow to the flue gas reference mass flow. This value ranges from zero to one. If the process flow in the tubes is less than this value, the HX coefficient used is set to zero. Outer Scaled U The actual HX coefficient used in the calculation if the Flow Scaled option is selected. Tube Properties Description Uused Uspecified mass massref ------------------⎝ ⎠ ⎛ ⎞ 0.8 = 4-81 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-82 Fired Heater (Furnace) ww ThEstimating Zone to Wall U requires trial and error techniques. Enter a value of U then observe the temperature profile of the flue gas exiting the radiant zone. 4.3.5 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the heat exchanger unit operation. To view the stream parameters broken down per stream phase, open the Worksheet tab of the stream property view. 4.3.6 Performance Tab The performance tab contains three pages which highlight the calculated temperature, duty, and pressure of the Fired Heater operation. The PF Specs page is relevant to dynamics cases only. Figure 4.36 Refer to Section 1.3.10 - Worksheet Tab for more information.4-82 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-83 ww ThDuty Page The Duty page displays the results of the Fired Heater energy balance calculation. The Duty page contains three levels/ branches: Radiant Zone, Convective Zone, and Economizer Zone. • If you select Radiant Zone from the tree browser, the following four levels/branches containing information regarding the Tube Duty results and Zone Duty results appear: - Overall - Holdup Figure 4.37 Figure 4.384-83 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-84 Fired Heater (Furnace) ww Th- Tubes - Wall Figure 4.39 Figure 4.404-84 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-85 ww Th• If you select the Convective Zone from the tree browser, the following parameters from the Tube Duty Results group and the Zone Duty Results group appear: • If you select the Economizer Zone from the tree browser, the following parameters from the Tube Duty results group and Zone Duty results group appear: Process Fluid Page The Process Fluid page contains two sub-pages: • Temperatures • Pressures In the Temperatures sub-page, the following parameters appear: • Inlet Temp, Inlet stream process fluid temperature • Outlet Temp, Outlet stream process fluid temperature • Tube Inner Temp, Tube inner wall temperature Figure 4.41 Figure 4.42 Sub pages on the Process Fluid page.4-85 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-86 Fired Heater (Furnace) ww ThIn the Pressures sub-page, the following parameters appear: • Inlet pressure, inlet stream pressure • Friction Delta P, friction pressure drop across the tube • Static Head Delta P, static pressure of the stream • Outlet Pressure, outlet stream pressure Flue Gas Page The Flue Gas page contains the following sub-pages: • Temperatures • Pressures • Flows On the Temperatures sub-page, you can view your flue gas temperature and Fired Heater inner/outer wall temperatures. Similarly, the Pressures sub-page displays the flue gas pressures, frictional delta P, and static head delta P. The Flow sub-page displays the flue gas molar/mass flow. Figure 4.434-86 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-87 ww Th4.3.7 Dynamics Tab The Dynamics tab contains information pertaining to pressure specifications for he dynamic calculations. The information is sorted into the following pages: • Tube Side PF • Flue Gas PF • Holdup Tube Side PF Page The Tube Side PF page allows you to specify how the pressure drop in each pass is calculated. The following table outlines the tube side PF options available on this page. Figure 4.44 Option Description Use K’s? If this checkbox is selected, the K method is used to calculate Delta P across the pass.4-87 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-88 Fired Heater (Furnace) ww ThFlue Gas PF Page On the Flue Gas PF page, you can specify how the pressure drop in each pass is calculated. The following table outlines the tube side PF options available on this page. Use Delta P Spec? If this checkbox is selected, the pressure drop is fixed at this specified value. Calculate K’s If this button is clicked, HYSYS calculates the K required to maintain a specified Delta P across a defined flow condition. Figure 4.45 Option Description Use PF K’s If this checkbox is selected, the K method is used to calculate Delta P across the pass. Use Delta P If this checkbox is selected, the pressure drop is fixed at this specified value. Calculate K’s If this button is clicked, HYSYS calculates the K required to maintain a specified Delta P across a defined flow condition. Option Description4-88 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-89 ww ThHoldup Page The Holdup page contains information regarding each stream’s holdup properties and composition. 4.4 Heat Exchanger The Heat Exchanger performs two-sided energy and material balance calculations. The Heat Exchanger is very flexible, and can solve for temperatures, pressures, heat flows (including heat loss and heat leak), material stream flows, or UA. In HYSYS, you can choose the Heat Exchanger Model for your analysis. Your choices include an End Point analysis design model, an ideal (Ft=1) counter-current Weighted design model, a steady state rating method, and a dynamic rating method for use in dynamic simulations. The dynamic rating method is available as either a Basic or Detailed model, and can also be used in Steady State mode for Heat Exchanger rating. The unit operation also allows the use of third party Heat Exchanger design methods via OLE Extensibility. Figure 4.46 Additional Heat Exchanger models, such as TASC and STX, are also available. Contact your local AspenTech representative for details. Refer to Section 1.3.3 - Holdup Page for more information. The Individual Holdups group contains two drop- down lists (Zone and Holdup) that enable you to select and view information on individual zone and holdup section.4-89 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-90 Heat Exchanger ww ThThe following are some of the key features of the dynamic Heat Exchanger operation: • A pressure-flow specification option which realistically models flow through the Heat Exchanger according to the pressure network of the plant. Possible flow reversal situations can therefore be modeled. • The choice between a Basic and Detailed Heat Exchanger model. Detailed Heat Exchanger rating information can be used to calculate the overall heat transfer coefficient and pressure drop across the Heat Exchanger. • A dynamic holdup model which calculates level in the Heat Exchanger shell based on its geometry and orientation. • A heat loss model which accounts for the convective and conductive heat transfer that occurs across the Heat Exchanger shell wall. 4.4.1 Theory The Heat Exchanger calculations are based on energy balances for the hot and cold fluids. Steady State In the following general relations, the hot fluid supplies the Heat Exchanger duty to the cold fluid: where: M = fluid mass flow rate H = enthalpy Qleak = heat leak In Dynamic mode, the shell and tube of the Heat Exchanger is capable of storing inventory like other dynamic vessel operations. The direction of flow of material through the Heat Exchanger is governed by the pressures of the surrounding unit operations. (4.28)Balance Error Mcold Hout Hin–[ ]cold Qleak–( ) Mhot Hin Hout–[ ]hot Qloss–( )–=4-90 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-91 ww ThQloss = heat loss Balance Error = a Heat Exchanger Specification that equals zero for most applications hot and cold = hot and cold fluids in and out = inlet and outlet stream The total heat transferred between the tube and shell sides (Heat Exchanger duty) can be defined in terms of the overall heat transfer coefficient, the area available for heat exchange, and the log mean temperature difference: where: U = overall heat transfer coefficient A = surface area available for heat transfer = log mean temperature difference (LMTD) Ft = LMTD correction factor The heat transfer coefficient and the surface area are often combined for convenience into a single variable referred to as UA. The LMTD and its correction factor are defined in the Performance section. The Heat Exchanger operation allows the heat curve for either side of the exchanger to be broken into intervals. Rather than calculating the energy transfer based on the terminal conditions of the exchanger, it is calculated for each of the intervals, then summed to determine the overall transfer. (4.29)Q UAΔTLMFt= ΔTTM4-91 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-92 Heat Exchanger ww ThDynamic The following general relation applies to the shell side of the Basic model Heat Exchanger. For the tube side: where: Mshell = shell fluid flow rate Mtube = tube fluid flow rate = density H = enthalpy Qloss = heat loss Q = heat transfer from the tube side to the shell side V = volume shell or tube holdup The term Qloss represents the heat lost from the shell side of the dynamic Heat Exchanger. For more information regarding how Qloss is calculated. Pressure Drop The pressure drop of the Heat Exchanger can be determined in one of three ways: • Specify the pressure drop. • Calculate the pressure drop based on the Heat Exchanger geometry and configuration. • Define a pressure flow relation in the Heat Exchanger by specifying a k-value. (4.30) (4.31) Mshell Hin Hout–( )shell Qloss– Q+ ρ d VHout( )shell dt ---------------------------------= Mtube Hin Hout–( )tube Q– ρ d VHout( )tube dt --------------------------------= ρ Refer to Section 1.3.4 - Heat Loss Model in the HYSYS Dynamic Modeling guide for more information.4-92 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-93 ww ThIf the pressure flow option is chosen for pressure drop determination in the Heat Exchanger, a k value is used to relate the frictional pressure loss and flow through the exchanger. This relation is similar to the general valve equation: This general flow equation uses the pressure drop across the Heat Exchanger without any static head contributions. The quantity, P1 - P2, is defined as the frictional pressure loss which is used to “size” the Heat Exchanger with a k-value. Dynamic Specifications The following tables list the minimum specifications required for the Heat Exchanger unit operation to solve in Dynamic mode. The Basic Heat Exchanger model requires the following dynamic specifications: (4.32) Specification Description Volume The tube and shell volumes must be specified. Overall UA The Overall UA must be specified. Pressure Drop Either specify an Overall Delta P or an Overall K-value for the Heat Exchanger. Specify the Pressure Drop calculation method in the Dynamic Specifications group on the Specs page of the Dynamics tab. You can also specify the Overall Delta P values for the shell and tube sides on the Sizing page of the Rating tab. f density k× P1 P2–=4-93 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-94 Heat Exchanger ww ThThe Detailed Heat Exchanger model requires the following dynamic specifications: 4.4.2 Heat Exchanger Property View There are two ways that you can add a Heat Exchanger to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Heat Transfer Equipment radio button. 3. From the list of available unit operations, select Heat Exchanger. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the Heat Exchanger icon. Specification Description Sizing Data The tube and shell sides of the Heat Exchanger must be completely specified on the Sizing page of the Rating tab. The overall tube/shell volumes, and the heat transfer surface area are calculated from the shell and tube ratings information. Overall UA Either specify an Overall UA or have it calculated from the Shell and Tube geometry. Specify the U calculation method on the Parameters page of the Rating tab. The U calculation method can also be specified on the Model page of the Dynamics tab. Pressure Drop Either specify an Overall Delta P or an Overall K-value for the Heat Exchanger. Specify the Pressure Drop calculation method on the Parameters page of the Rating tab. You can also specify the Pressure Drop calculation method in the Pressure Flow Specifications group on the Specs page of the Dynamics tab. Heat Exchanger icon4-94 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-95 ww ThThe Heat Exchanger property view is displayed. The Update button enables you to update the heat exchanger calculation when in Dynamic mode. For example, if you make a configurational change to the heat exchanger, click this button to reset the equations around the heat exchanger before running the simulation calculation in Dynamic mode. 4.4.3 Design Tab The Design tab contains the following pages: • Connections • Parameters • Specs • User Variables • Notes Figure 4.474-95 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-96 Heat Exchanger ww ThConnections Page The Connections page allows you to specify the operation name, and the inlet and outlet streams of the shell and tube. The main flowsheet is the default flowsheet for the Tube and Shell side. You can select a subflowsheet on the Tube and/or Shell side which allows you to choose inlet and outlet streams from that flowsheet. This is useful for processes such as the Refrigeration cycle, which require separate fluid packages for each side. You can define a subflowsheet with a different fluid package, and then connect to the main flowsheet Heat Exchanger. Parameters Page The Parameters page allows you to select the Heat Exchanger Model and specify relevant physical data. The parameters appearing on the Parameters page depend on which Heat Exchanger Model you select. Figure 4.48 When a heat exchanger is installed as part of a column subflowsheet (available when using the Modified HYSIM Inside-Out solving method) these Heat Exchanger Models are not available. Instead, in the column subflowsheet, the heat exchanger is “Calculated from Column” as a simple heat and mass balance.4-96 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-97 ww ThFrom the Heat Exchanger Model drop-down list, select the calculation model for the Heat Exchanger. The following Heat Exchanger models are available: • Exchanger Design (Endpoint) • Exchanger Design (Weighted) • Steady State Rating • Dynamic Rating • HTFS - Engine • TASC Heat Exchanger For both the Endpoint and Weighted models, you can specify whether your Heat Exchanger experiences heat leak/loss. • Heat Leak. Loss of cold side duty due to leakage. Duty gained to reflect the increase in temperature. • Heat Loss. Loss of hot side duty due to leakage. Duty lost to reflect the decrease in temperature. The table below describes the radio buttons in the Heat Leak/ Loss group of the Endpoint and Weighted models. All Heat Exchanger models allow for the specification of either Counter or Co-Current tube flow. End Point Model The End Point model is based on the standard Heat Exchanger duty equation (Equation (4.29)) defined in terms of overall heat transfer coefficient, area available for heat exchange, and the log mean temperature difference (LMTD). The HTFS - Engine and TASC Heat Exchanger options are only available if you have installed TASC. Radio Button Description None By default, the None radio button is selected. Extremes On the hot side, the heat is considered to be “lost” where the temperature is highest. Essentially, the top of the heat curve is being removed to allow for the heat loss/leak. This is the worst possible scenario. On the cold side, the heat is gained where the temperature is lowest. Proportional The heat loss is distributed over all of the intervals. Refer to the TASC Thermal Reference guide for more information. Refer to Section 4.4.4 - Rating Tab for further details.4-97 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-98 Heat Exchanger ww ThThe main assumptions of the model are as follows: • Overall heat transfer coefficient, U is constant. • Specific heats of both shell and tube side streams are constant. The End Point model treats the heat curves for both Heat Exchanger sides as linear. For simple problems where there is no phase change and Cp is relatively constant, this option may be sufficient to model your Heat Exchanger. For non-linear heat flow problems, the Weighted model should be used instead. The following parameters are available when the End Point model is selected: Figure 4.49 Parameters Description Tubeside and Shellside Delta P The pressure drops (DP) for the tube and shell sides of the exchanger can be specified here. If you do not specify the Delta P values, HYSYS calculates them from the attached stream pressures. UA The product of the Overall Heat Transfer Coefficient, and the Total Area available for heat transfer. The Heat Exchanger duty is proportional to the log mean temperature difference, where UA is the proportionality factor. The UA can either be specified, or calculated by HYSYS. Exchanger Geometry The Exchanger Geometry is used to calculate the Ft Factor using the End Point Model. It is not available for the weighted model. Refer to the Rating tab for more information on the Exchanger Geometry.4-98 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-99 ww ThWeighted Model The Weighted model is an excellent model to apply to non-linear heat curve problems such as the phase change of pure components in one or both Heat Exchanger sides. With the Weighted model, the heating curves are broken into intervals, and an energy balance is performed along each interval. A LMTD and UA are calculated for each interval in the heat curve, and summed to calculate the overall exchanger UA. The Weighted model is available only for counter-current exchangers, and is essentially an energy and material balance model. The geometry configurations which affect the Ft correction factor are not taken into consideration in this model. When you select the Weighted model, the Parameters page appears as shown in the figure below. Figure 4.504-99 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-100 Heat Exchanger ww ThThe following table describes the parameters available on the Parameters page when the Weighted model is selected: Parameters Description Tubeside and Shellside Delta P The pressure drops (DP) for the tube and shell sides of the exchanger can be specified here. If you do not specify the DP values, HYSYS calculates them from the attached stream pressures. UA The product of the Overall Heat Transfer Coefficient and the Total Area available for heat transfer. The Heat Exchanger duty is proportional to the log mean temperature difference, where UA is the proportionality factor. The UA can either be specified, or calculated by HYSYS. Individual Heat Curve Details For each side of the Heat Exchanger, the following parameters appear (all but the Pass Names can be modified). • Pass Name. Identifies the shell and tube side according to the names you provided on the Connections page. • Intervals. The number of intervals can be specified. For non-linear temperature profiles, more intervals are necessary. • Dew/Bubble Point. Select this checkbox to add a point to the heat curve for the dew and/or bubble point. If there is a phase change occurring in either pass, the appropriate checkbox should be selected. There are three choices for the Step Type: • Equal Enthalpy. All intervals have an equal enthalpy change. • Equal Temperature. All intervals have an equal temperature change. • Auto Interval. HYSYS determines where points should be added to the heat curve. This is designed to minimize error using the least number of intervals. The Pressure Profile is updated in the outer iteration loop, using one of the following methods: • Constant dPdH.Maintains constant dPdH during update. • Constant dPdUA.Maintains constant dPdUA during update. • Constant dPdA. Maintains constant dPdA during update. This is not currently applicable to the Heat Exchanger, as the area is not predicted. • Inlet Pressure.Pressure is constant and equal to the inlet pressure. • Outlet Pressure. Pressure is constant and equal to the outlet pressure.4-100 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-101 ww ThSteady State Rating Model The Steady State Rating model is an extension of the End Point model to incorporate a rating calculation, and uses the same assumptions as the End Point model. If you provide detailed geometry information, you can rate the exchanger using this model. As the name suggests, this model is only available for steady state rating. When dealing with linear or nearly linear heat curve problems, the Steady State Rating model should be used. Due to the solver method incorporated into this rating model, the Steady State Rating model can perform calculations exceptionally faster than the Dynamic Rating model. The following parameters are available on the Parameters page when the Steady State Rating model is selected: Figure 4.51 Parameters Description Tubeside and Shellside Delta P The pressure drops (DP) for the tube and shell sides of the exchanger can be specified here. If you do not specify the Delta P values, HYSYS calculates them from the attached stream pressures. UA The product of the Overall Heat Transfer Coefficient, and the Total Area available for heat transfer. The Heat Exchanger duty is proportional to the log mean temperature difference, where UA is the proportionality factor. The UA can either be specified, or calculated by HYSYS.4-101 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-102 Heat Exchanger ww ThDynamic Rating Two models are available for Dynamic Rating using the Heat Exchanger unit operation: a Basic and a Detailed model. If you specify three temperatures or two temperatures and a UA, you can rate the exchanger with the Basic model. If you provide detailed geometry information, you can rate the exchanger using the Detailed model. The Basic model is based on the same assumptions as the End Point model, which uses the standard Heat Exchanger duty equation (Equation (4.29)) defined in terms of overall heat transfer coefficient, area available for heat exchange, and the log mean temperature difference. The Basic model is actually the counterpart of the End Point model for dynamics and dynamic rating. The Basic model can also be used for steady state Heat Exchanger rating. The Detailed model is based on the same assumptions as the Weighted model, and divides the Heat Exchanger into a number of heat zones, performing an energy balance along each interval. This model requires detailed geometry information about your Heat Exchanger. The Detailed model is actually the counterpart of the Weighted model for dynamics and dynamic rating, but can also be used for steady state Heat Exchanger rating. The Specs page no longer appears when Dynamic Rating is selected. Figure 4.524-102 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-103 ww ThThe Basic and Detailed Dynamic Rating models share rating information with the Dynamics Heat Exchanger model. Any rating information entered using these models is observed in Dynamic mode. Once the Dynamic Rating model is selected, no further information is required on the Parameters page of the Design tab. You can choose the model (Basic or Detailed) on the Parameters page of the Rating tab. HTFS - Engine The figure below shows the Parameters page of the Design tab, if you select the HTFS - Engine model. Notice that the values in the fields appear in black, indicating that they are HYSYS calculated values, and you cannot change them in the current fields. To change the variable values shown on this page, you have to go to the HTFS - TASC tab on the Heat Exchanger property view. Refer to Section 4.4.8 - HTFS-TASC Tab for more information. Specs Page The Specs page includes three groups that organize various specifications and solver information. The information provided on the Specs page is only valid for the Weighted, Endpoint, and Steady State Rating models. Figure 4.534-103 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-104 Heat Exchanger ww Th Solver Group The following parameters are listed in the Solver group: Unknown Variables Group HYSYS lists all unknown Heat Exchanger variables according to your specifications. Once the unit has solved, the values of these variables appear. If you are working with a Dynamic Rating model, the Specs page does not appear on the Design tab. Figure 4.54 Parameters Details Tolerance The calculation error tolerance can be set. Current Error When the current error is less than the calculation tolerance, the solution is considered to have converged. Iterations The current iteration of the outer loop appears. In the outer loop, the heat curve is updated and the property package calculations are performed. Non-rigorous property calculations are performed in the inner loop. Any constraints are also considered in the inner loop.4-104 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-105 ww ThSpecifications Group The Heat Balance (specified at 0 kJ/h) is considered to be a constraint. This is a Duty Error spec, which you cannot turn off. Without the Heat Balance specification, you could, for example, completely specify all four Heat Exchanger streams, and have HYSYS calculate the Heat Balance error which would be displayed in the Current Value column of the Specifications group. The UA is also included as a default specification. HYSYS displays this as a convenience, since it is a common specification. You can either use this spec or deactivate it. You can view or delete highlighted specifications by using the buttons at the right of the group. A specification property view appears automatically each time a new spec is created via the Add button. The figure below shows a typical property view of a specification, which is accessed via the View or Add button. Each specification property view has the following tabs: • Parameters • Summary The Summary page is used to define whether the specification is Active or an Estimate. The Spec Value is also shown on this page. Without the Heat Balance specification, the heat equation is not balanced. Figure 4.55 Defining the Delta Temp spec requires two stream names and a value for the specification.4-105 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-106 Heat Exchanger ww ThAll specifications are one of the following three types: The specification list allows you to try different combinations of the above three specification types. For example, suppose you have a number of specifications, and you want to determine which ones should be active, which should be estimates and which ones should be ignored altogether. By manipulating the checkboxes among various specifications, you can test various combinations of the three types to see their effect on the results. Information specified on the specification property view also appears in the Specifications group. Specification Type Description Active An active specification is one that the convergence algorithm is trying to meet. An active specification always serves as an initial estimate (when the Active checkbox is selected, HYSYS automatically selects the Estimate checkbox). An active specification exhausts one degree of freedom. An Active specification is one that the convergence algorithm is trying to meet. An Active specification is on when both checkboxes are selected. Estimate An Estimate is considered an Inactive specification because the convergence algorithm is not trying to satisfy it. To use a specification as an estimate only, clear the Active checkbox. The value then serves only as an initial estimate for the convergence algorithm. An estimate does not use an available degree of freedom. An Estimate is used as an initial “guess” for the convergence algorithm, and is considered to be an inactive specification. Completely Inactive To disregard the value of a specification entirely during convergence, clear both the Active and Estimate checkboxes. By ignoring rather than deleting a specification, it remains available if you want to use it later. A Completely Inactive specification is one that is ignored completely by the convergence algorithm, but can be made Active or an Estimate at a later time.4-106 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-107 ww ThThe available specification types include the following: User Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor that allows you to record any comments or information regarding the specific unit operation or the simulation case in general. Specification Description Temperature The temperature of any stream attached to the Heat Exchanger. The hot or cold inlet equilibrium temperature can also be defined. • The Hot Inlet Equilibrium temperature is the temperature of the inlet hot stream minus the heat loss temperature drop. • The Cold Inlet Equilibrium temperature is the temperature of the inlet cold stream plus the heat leak temperature rise. Delta Temp The temperature difference at the inlet or outlet between any two streams attached to the Heat Exchanger. The hot or cold inlet equilibrium temperatures (which incorporate the heat loss/heat leak with the inlet conditions) can also be used. Minimum Approach Minimum internal temperature approach. The minimum temperature difference between the hot and cold stream (not necessarily at the inlet or outlet). UA The overall UA (product of overall heat transfer coefficient and heat transfer area). LMTD The overall log mean temperature difference. Duty The overall duty, duty error, heat leak or heat loss. The duty error should normally be specified as 0 so that the heat balance is satisfied. The heat leak and heat loss are available as specifications only if the Heat Loss/Leak is set to Extremes or Proportional on the Parameters page. Duty Ratio A duty ratio can be specified between any two of the following duties: overall, error, heat loss, and heat leak. Flow The flowrate of any attached stream (molar, mass or liquid volume). Flow Ratio The ratio of the two inlet stream flowrates. All other ratios are either impossible or redundant (in other words, the inlet and outlet flowrates on the shell or tube side are equal). For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.4-107 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-108 Heat Exchanger ww Th4.4.4 Rating Tab The Rating tab contains the following pages: • Sizing • Parameters • Nozzles • Heat Loss Sizing Page The Sizing page provides Heat Exchanger sizing related information. Based on the geometry information, HYSYS is able to calculate the pressure drop and the convective heat transfer coefficients for both Heat Exchanger sides and rate the exchanger. The information is grouped under three radio buttons: • Overall • Shell • Tube The Parameters page is used exclusively by the dynamics Heat Exchanger, and only becomes active either in Dynamic mode or while using the Dynamic Rating model.4-108 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-109 ww ThOverall When you select the Overall radio button, the overall Heat Exchanger geometry appears: In the Configuration group, you can specify whether multiple shells are used in the Heat Exchanger design. The following fields appear, and can be modified in, the Configuration group. Figure 4.56 Field Description Number of Shell Passes You have the option of HYSYS performing the calculations for Counter Current (ideal with Ft = 1.0) operation, or for a specified number of shell passes. Specify the number of shell passes to be any integer between 1 and 7. When the shell pass number is specified, HYSYS calculates the LMTD correction factor (Ft) for the current exchanger design. A value lower than 0.8 generally corresponds to inefficient design in terms of the use of heat transfer surface. More passes or larger temperature differences should be used in this case. For n shell passes, HYSYS solves the heat exchanger on the basis that at least 2n tube passes exist. Charts for Shell and Tube Exchanger LMTD Correction Factors, as found in the GPSA Engineering Data Book, are normally in terms of n shell passes and 2n or more tube passes. Tube flow direction can be defined as either Counter or Co-Current for all heat exchanger calculation models.4-109 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-110 Heat Exchanger ww ThYou can specify the number of shell and tube passes in the shell of the Heat Exchanger. In general, at least 2n tube passes must be specified for every n shell pass. The exception is a counter- current flow Heat Exchanger which has 1 shell pass and one tube pass. The orientation can be specified as a vertical or horizontal Heat Exchanger. The orientation of the Heat Exchanger does not impact the steady state solver, however, it is Number of Shells in Series If a multiple number of shells are specified in series, the configuration is shown as follows: Number of Shells in Parallel If a multiple number of shells are specified in parallel, the configuration is shown as follows: Currently, multiple shells in parallel are not supported in HYSYS. Tube Passes per Shell The number of tube passes per shell. The default setting is 2 (in other words, the number of tubes equal to 2n, where n is the number of shells.) Exchanger Orientation The exchanger orientation defines whether or not the shell is horizontal or vertical. Used only in dynamic simulations. When the shell orientation is vertical, you can also specify whether the shell feed is at the top or bottom via the Shell Feed at Bottom checkbox. The Shell Feed at Bottom checkbox is only visible for the vertical oriented exchanger. First Tube Pass Flow Direction Specifies whether or not the tube feed is co-current or counter-current. Elevation (base) The height of the base of the exchanger above the ground. Used only in dynamic simulations. Field Description4-110 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-111 ww Thused in the Dynamics Heat Exchanger Model in the calculation of liquid level in the shell. The shape of Heat Exchanger can be specified using the TEMA- style drop-down lists. The first list contains a list of front end stationary head types of the Heat Exchanger. The second list contains a list of shell types. The third list contains a list of rear end head types. In the Calculated Information group, the following Heat Exchanger parameters are listed: • Shell HT Coeff • Tube HT Coeff • Overall U • Overall UA • Shell DP • Tube DP • Heat Trans. Area per Shell • Tube Volume per Shell • Shell Volume per Shell Figure 4.57 For a more detailed discussion of TEMA-style shell-and-tube heat exchangers, refer to page 11-33 of the Perry’s Chemical Engineers’ Handbook (1997 edition).4-111 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-112 Heat Exchanger ww ThShell Selecting the Shell radio button allows you to specify the shell configuration and the baffle arrangement in each shell. In the Shell and Tube Bundle Data group, you can specify whether multiple shells are used in the Heat Exchanger design. The following fields appear, and can be modified in, the Shell and Tube Bundle Data group. Figure 4.58 Field Description Shell Diameter Diameter of the shell(s). Number of Tubes per Shell Number of tubes per shell. You can change the value in this field. Tube Pitch Shortest distance between the centres of two adjacent tubes. Tube Layout Angle In HYSYS, the tubes in a single shell can be arranged in four different symmetrical patterns: • Triangular (30°) • Triangular Rotated (60°) • Square (90°) • Square Rotated (45°) For more information regarding the benefits of different tube layout angles, refer to page 139 of Process Heat Transfer by Donald Q. Kern (1965) Shell Fouling The shell fouling factor is taken into account in the calculation of the overall heat transfer coefficient, UA.4-112 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-113 ww ThThe following fields appear, and can be modified in, the Shell Baffles group: Tube Selecting the Tube radio button allows you to specify the tube geometry information in each shell. The Dimensions group allows you to specify the following tube geometric parameters: Field Description Shell Baffle Type You can choose from four different baffle types: • Single • Double • Triple • Grid Shell Baffle Orientation You can choose whether the baffles are aligned horizontally or vertically along the inner shell wall. Baffle cut (Area%) You can specify the percent area where the liquid flows through relative to the cross sectional area of the shell. The baffle cut is expressed as a percent of net free area. The net free area is defined as the total cross- sectional area in the flow direction parallel to the tubes minus the area blocked off by the tubes (essentially the percentage of open area). Baffle Spacing You can specify the space between each baffle. Figure 4.59 Field Description Outer Tube Diameter (OD) Inner Tube Diameter (ID) Tube Thickness Two of the three listed parameters must be specified to characterize the tube width dimensions. Tube Length Heat transfer length of one tube in a single Heat Exchanger shell. This value is not the actual tube length.4-113 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-114 Heat Exchanger ww ThIn the Tube Properties group, the following metal tube heat transfer properties must be specified: • Tube Fouling Factor • Thermal Conductivity • Wall Specific Heat Capacity, Cp • Wall Density Parameters Page The Parameters page of the Rating tab is used to define rating parameters for the Dynamic Rating model. On the Parameters page, you can specify either a Basic model or a Detailed model. For the Basic model, you must define the Heat Exchanger overall UA and pressure drop across the shell and tube. For the Detailed model, you must define the geometry and heat transfer parameters of both the shell and tube sides in the Heat Exchanger operation. In order for either the Basic or Detailed Heat Exchanger Model to completely solve, the Parameters page must be completed. Basic Model When you select the Basic model radio button on the Parameters page in Dynamic mode, the following property view appears. The Dimensions group contains the following information: • Tube Volume • Shell Volume • Elevation (Base) Figure 4.604-114 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-115 ww ThThe tube volume, shell volume, and heat transfer area are calculated from Shell and Tube properties specified by selecting the Shell and Tube radio buttons on the Sizing page. The elevation of the base of the Heat Exchanger can be specified but does not impact the steady state solver. The Prevent Temperature Cross checkbox is used to activate additional model options when selected. These additional model options prevent temperature crosses by automatically reducing the heat transfer rate slowly. The Parameters group includes the following Heat Exchanger parameters. All but the correction factor, F, can be modified: Field Description Overall UA The product of the Overall Heat Transfer Coefficient, and the Total Area available for heat transfer. The Heat Exchanger duty is proportional to the log mean temperature difference, where UA is the proportionality factor. The UA can either be specified, or calculated by HYSYS. Tubeside and Shellside Delta P The pressure drops (DP) for the tube and shell sides of the exchanger can be specified here. If you do not specify the DP values, HYSYS calculates them from the attached stream pressures.4-115 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-116 Heat Exchanger ww ThDetailed Model The Detailed model option allows you to specify the zone information, heat transfer coefficient, and Delta P details. When you select the Detailed model radio button on the Parameters page, the following property view appears. Zone Information HYSYS can partition the Heat Exchanger into discrete multiple sections called zones. Because shell and tube stream conditions do not remain constant across the operation, the heat transfer parameters are not the same along the length of the Heat Exchanger. By dividing the Heat Exchanger into zones, you can make different heat transfer specifications for individual zones, and therefore more accurately model an actual Heat Exchanger. In the Zone Information group you can specify the following: Figure 4.61 Field Description Zones per Shell Pass Enter the number of zones you want for one shell. The total number of zones in a Heat Exchanger shell is calculated as: Zone Fraction The fraction of space the zone occupies relative to the total shell volume. HYSYS automatically sets each zone to have the same volume. You can modify the zone fractions to occupy a larger or smaller proportion of the total volume. Click the Normalize Zone Fractions button in order to adjust the sum of fractions to equal one. Total Zones Total Shell Passes Zones⋅=4-116 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-117 ww ThHeat Transfer Coefficients The Heat Transfer Coefficients group contains information regarding the calculation of the overall heat transfer coefficient, UA, and local heat transfer coefficients for the fluid in the tube, hi, and the fluid surrounding the tube, ho. The heat transfer coefficients can be determined in one of two ways: • The heat transfer coefficients can be specified using the rating information provided on the Parameters page and the stream conditions. • You can specify the heat transfer coefficients. For fluids without phase change, the local heat transfer coefficient, hi, is calculated according to the Sieder-Tate correlation: where: Gi = mass velocity of the fluid in the tubes (velocity*density) = viscosity of the fluid in the tube = viscosity of the fluid inside tubes, at the tube wall Cp,i = specific heat capacity of the fluid inside the tube The relationship between the local heat transfer coefficients, and the overall heat transfer coefficient is shown in Equation (4.34). where: U = overall heat transfer coefficient ho = local heat transfer coefficient outside tube hi = local heat transfer coefficient inside tube (4.33) (4.34) hi 0.027km Di ------------------- DiGi μi -----------⎝ ⎠ ⎛ ⎞ 0.8 Cp i, μi km --------------⎝ ⎠ ⎛ ⎞ 1 3⁄ μi μi w, ---------⎝ ⎠ ⎛ ⎞ 0.14 = μi μi w, U 1 1 ho ---- ro rw Do Di ------ ri 1 hi ---+⎝ ⎠ ⎛ ⎞+ + + --------------------------------------------------------------------=4-117 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-118 Heat Exchanger ww Thro = fouling factor outside tube ri = fouling factor inside tube rw = tube wall resistance Do = outside diameter of tube Di = inside diameter of tube The Heat Transfer coefficients group contains the following information: Delta P The Delta P group contains information regarding the calculation of the shell and tube pressure drop across the exchanger. In Steady State mode, the pressure drop across either the shell or tube side of the Heat Exchanger can be calculated in one of two ways: • The pressure drop can be calculated from the rating information provided in the Sizing page and the stream conditions. • The pressure drop can be specified. Field Description Shell/Tube Heat Transfer Coefficient The local Heat Transfer Coefficients, ho and hi, can be specified or calculated. Shell/Tube HT Coefficient Calculator The Heat Transfer Coefficient Calculator allows you to either specify or calculate the local Heat Transfer Coefficients. Specify the cell with one of following options: • Shell & Tube. The local heat transfer coefficients, ho and hi, are calculated using the heat exchange rating information and correlations. • U specified. The local heat transfer coefficients, ho and hi, are specified by you.4-118 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-119 ww ThThe Delta P group contains the following information: Detailed Heat Model Properties When you click the Specify Parameters for Individual Zones button, the Detailed Heat Model Properties property view appears. The Detailed Heat Model Properties property view displays the detailed heat transfer parameters and holdup conditions for each zone. HYSYS uses the following terms to describe different locations within the Heat Exchanger. Field Description Shell/Tube Delta P The pressure drop across the Shell/Tube side of the Heat Exchanger can be specified or calculated. Shell/Tube Delta P Calculator The Shell/Tube Delta P Calculator allows you to either specify or calculate the shell/tube pressure drop across the Heat Exchanger. Specify the cell with one of following options: • Shell & Tube Delta P Calculator. The pressure drop is calculated using the Heat Exchanger rating information and correlations. • User specified. The pressure drop is specified by you. • Non specified. This option is only applicable in Dynamic mode. Pressure drop across the Heat Exchanger is calculated from a pressure flow relation. Location Term Description Zone HYSYS represents the zone using the letter “Z”. Zones are numbered starting from 0. For instance, if there are 3 zones in a Heat Exchanger, the zones are labeled: Z0, Z1, and Z2. Holdup HYSYS represents the holdup within each zone with the letter “H”. Holdups are numbered starting from 0. “Holdup 0” is always the holdup of the shell within the zone. Holdups 1 through n represents the n tube holdups existing in the zone. Tube Location HYSYS represents tube locations using the letters “TH”. Tube locations occur at the interface of each zone. Depending on the number of tube passes per shell pass, there can be several tube locations within a particular zone. For instance, 2 tube locations exist for each zone in a Heat Exchanger with 1 shell pass and 2 tube passes. Tube locations are numbered starting from 1.4-119 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-120 Heat Exchanger ww ThConsider a shell and tube Heat Exchanger with 3 zones, 1 shell pass, and 2 tube passes. The following diagram labels zones, tube locations, and hold-ups within the Heat Exchanger: Heat Transfer (Individual) Tab Information regarding the heat transfer elements of each tube location in the Heat Exchanger appears on the Heat Transfer (Individual) tab. Figure 4.62 Figure 4.634-120 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-121 ww ThHeat transfer from the fluid in the tube to the fluid in the shell occurs through a series of heat transfer resistances or elements. There are two convective elements, and one conductive element associated with each tube location. This tab organizes all the heat transfer elements for each tube location in one spreadsheet. You can choose whether Conductive or Convective elements will appear by selecting the appropriate element type in the Heat Transfer Type drop-down list. The following is a list of possible elements for each tube location: Heat Transfer (Global) Tab The Heat Transfer (Global) tab displays the heat transfer elements for the entire Heat Exchanger. You can choose whether the overall Conductive or Convective elements are to appear by selecting the appropriate element type in the Heat Transfer Type drop-down list. Tabular Results Tab The Tabular Results tab displays the following stream properties for the shell and tube fluid flow paths. The feed and exit stream conditions appear for each zone. • Temperature • Pressure • Vapour Fraction Heat Transfer Element Description Convective Element The Shell Side element is associated with the local heat transfer coefficient, ho, around the tube. The Tube Side is associated with the local heat transfer coefficient, hi, inside the tube.These local heat transfer coefficients can be calculated by HYSYS or modified by you. Conductive Element This element is associated with the conduction of heat through the metal wall of the tube. The conductivity of the tube metal, and the inside and outside metal wall temperatures appear. You can modify the conductivity.4-121 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-122 Heat Exchanger ww Th• Molar Flow • Enthalpy • Cumulative UA • Cumulative Heat Flow • Length (into Heat Exchanger) Specs (Individual) Tab The Specs (Individual) tab displays the pressure drop specifications for each shell and tube holdup in one spreadsheet. The Pressure Flow K and Use Pressure Flow K columns are applicable only in Dynamic mode. You can choose whether the flow path is shell or tube side by selecting the appropriate flow path in the Display which flow path? drop-down list. Figure 4.64 You can choose whether the shell or tube side appears by selecting the appropriate flow path in the Display which flow path? drop-down list.4-122 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-123 ww ThSpecs (Global) Tab The Specs (Global) tab displays the pressure drop specifications for the entire shell and tube holdups. The Pressure Flow K and Use Pressure Flow K columns are applicable only in Dynamic mode. You can choose whether the shell or tube side appears by selecting the appropriate flow path in the Display which flow path? drop-down list. Plots Tab The information displayed on the Plots tab is a graphical representation of the parameters provided on the Tabular Results tab. You can plot the following variables for the shell and tube side of the Heat Exchanger: • Vapour Fraction • Molar Flow • Enthalpy • Cumulative UA • Heat Flow • Length Nozzles Page The Nozzles page contains information regarding the elevation and diameter of the nozzles. The placement of feed and product nozzles on the Detailed Dynamic Heat Exchanger operation has physical meaning. The exit stream’s composition depends on the exit stream nozzle’s location and diameter in relation to the physical holdup level in the vessel. If the product nozzle is located below the liquid level in the vessel, the exit stream draws material from the liquid holdup. If the product nozzle is located above the liquid level, the exit stream draws material from the vapour holdup. Refer to Section 1.3.6 - Nozzles Page for more information.4-123 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-124 Heat Exchanger ww ThIf the liquid level sits across a nozzle, the mole fraction of liquid in the product stream varies linearly with how far up the nozzle the liquid is. Essentially, all vessel operations in HYSYS are treated the same. The compositions and phase fractions of each product stream depend solely on the relative levels of each phase in the holdup and the placement of the product nozzles, so a vapour product nozzle does not necessarily produce pure vapour. A 3-phase separator may not produce two distinct liquid phase products from its product nozzles. Heat Loss Page The Heat Loss page contains heat loss parameters which characterize the amount of heat lost across the vessel wall. You can choose either to have no heat loss model, a Simple heat loss model or a Detailed heat loss model. Simple Heat Loss Model Figure 4.654-124 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-125 ww ThWhen you select the Simple radio button, the following parameters appear: • Overall U • Ambient Temperature • Overall Heat Transfer Area • Heat Flow Detailed Heat Loss Model The Detailed model allows you to specify more detailed heat transfer parameters. The HYSYS Dynamics license is required to use the Detailed Heat Loss model found on this page. 4.4.5 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the Heat Exchanger unit operation. To view the stream parameters broken down per stream phase, open the Worksheet tab of the stream property view. 4.4.6 Performance Tab The Performance tab has pages that display the results of the Heat Exchanger calculations in overall performance parameters, as well as using plots and tables. The Performance tab contains the following pages: • Details • Plots • Tables • Setup • Error Msg The PF Specs page is relevant to dynamics cases only. Refer to Section 1.6.1 - Detailed Heat Model in the HYSYS Dynamic Modeling guide for more information. Refer to Section 1.3.10 - Worksheet Tab for more information.4-125 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-126 Heat Exchanger ww ThDetails Page The information from the Details page appears in the figure below. Overall Performance Group The Overall and Detailed performance groups contain the following parameters that are calculated by HYSYS: Figure 4.66 The appearance of this page is slightly different for the Dynamic Rating model. Parameter Description Duty Heat flow from the hot stream to the cold stream. Heat Leak Loss of cold side duty due to leakage. Duty gained to reflect the increase in temperature. Heat Loss Loss of the hot side duty to leakage. The overall duty plus the heat loss is equal to the individual hot stream duty defined on the Tables page. UA Product of the Overall Heat Transfer Coefficient, and the Total Area available for heat transfer. The UA is equal to the overall duty divided by the LMTD. Minimum Approach The minimum temperature difference between the hot and cold stream. Mean Temp Driving Force The average temperature difference between the hot and cold stream. Dynamic Rating Steady State Rating4-126 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-127 ww ThUncorrected LMTD equation: where: LMTD The uncorrected LMTD multiplied by the Ft factor. For the Weighted Rating Method, the uncorrected LMTD equals the effective LMTD. UA Curvature Error The LMTD is ordinarily calculated using constant heat capacity. An LMTD can also be calculated using linear heat capacity. In either case, a different UA is predicted. The UA Curvature Error reflects the difference between these UAs. Hot Pinch Temperature The hot stream temperature at the minimum approach. Cold Pinch Temperature The cold stream temperature at the minimum approach. Ft Factor The LMTD (log mean temperature difference) correction factor, Ft, is calculated as a function of the Number of Shell Passes and the temperature approaches. For a counter- current Heat Exchanger, Ft is 1.0. For the Weighted rating method, Ft = 1. Uncorrected LMTD (Applicable only for the End Point method) - The LMTD is calculated in terms of the temperature approaches (terminal temperature differences) in the exchanger, using the Equation (4.35). (4.35) Parameter Description ΔTLM ΔT1 ΔT2– ΔT1 ΔT2( )⁄( )ln --------------------------------------= ΔT1 Thot out, Tcold in,–= ΔT2 Thot in, Tcold o, ut–=4-127 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-128 Heat Exchanger ww ThPlots Page You can plot curves for the hot and/or cold fluid. Use the Plot checkboxes to specify which side(s) of the exchanger should be plotted. The following default variables can be plotted along either the X or Y-axis: • Temperature • UA • Delta T • Enthalpy • Pressure • Heat Flow Select the combination from the Plot Type drop-down list. To Plot other available variables, you need to add them on the Setup page. Once the variables are added, they are available in the X and Y drop-down lists. Figure 4.67 You can modify the appearance of the plot via the Graph Control property view. Refer to Section 1.3.1 - Graph Control Property View for more information.4-128 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-129 ww ThTables Page On the Tables page, you can view (default variables) interval temperature, pressure, heat flow, enthalpy, UA, and vapour fraction for each side of the Exchanger in a tabular format. Select either the Shell Side or Tube Side radio button. To view other available variables, you need to add them on the Setup page. Variables are displayed based on Phase Viewing Options selected. Setup Page The Setup page allows you to filter and add variables to be viewed on the Plots and Tables pages. The variables that are listed in the Selected Viewing Variables group are available in the X and Y drop down list for plotting on the Plots page. The variables are also available for tabular plot results on the Tables page based on the Phase Viewing Options selected. Error Msg Page The Error Msg page contains a list of the warning messages on the Heat Exchanger. You cannot add comments to this page. Use it to see if there are any warnings in modeling the Heat Exchanger. 4-129 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-130 Heat Exchanger ww Th4.4.7 Dynamics Tab The Dynamics tab contains the following pages: • Model • Specs • Holdup • Stripchart Any information specified on the Rating tab also appears in the Dynamics tab. Model Page In the Model page, you can specify whether HYSYS uses a Basic or Detailed model. If you are working exclusively in Steady State mode, you are not required to change any information on the pages accessible through the Dynamics tab. Figure 4.684-130 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-131 ww ThBasic Model The Model Parameters group contains the following information for the Heat Exchanger unit operation: The Summary group contains information regarding the duty of the Heat Exchanger shell and tube sides. Field Description Tube/Shell Volume The volume of the shell and tube must be specified in the Basic model. Elevation The elevation is significant in the calculation of static head around and in the Heat Exchanger. Overall UA Product of the Overall Heat Transfer Coefficient and the Total Area available for heat transfer. The Heat Exchanger duty is proportional to the log mean temperature difference, where UA is the proportionality factor. The UA must be specified if the Basic model is used. Shell/Tube UA Reference Flow Since UA depends on flow, these parameters allow you to set a reference point that uses HYSYS to calculate a more realistic UA value. If no reference point is set then UA is fixed. If the UA is specified, the specified UA value does not change during the simulation. The UA value that is used, however, does change if a Reference Flow is specified. Basically, as in most heat transfer correlation's, the heat transfer coefficient is proportional to the . The equation below is used to determine the UA used: (4.36) Reference flows generally help to stabilize the system when you do shut downs and startups as well. Minimum Flow Scale Factor The ratio of mass flow at time t to reference mass flow is also known as flow scaled factor. The minimum flow scaled factor is the lowest value which the ratio is anticipated at low flow regions. This value can be expressed in a positive value or negative value. • A positive value ensures that some heat transfer still takes place at very low flows. • A negative value ignores heat transfer at very low flows. A negative factor is often used in shut downs if you are not interested in the results or run into problems shutting down an exchanger. If the Minimum Flow Scale Factor is specified, the Equations (4.36) uses the ratio if the ratio is greater than the Min Flow Scale Factor. Otherwise the Min Flow Scale Factor is used. In some cases you can use a negative value for minimum flow scale factor. If you use -0.1, then if the scale factor goes below 0.1, the Minimum Flow Scale Factor uses 0. mass flow ratio( )0.8 UAused UAspecified mass flowcurrent mass flowreference -----------------------------------------⎝ ⎠ ⎛ ⎞ 0.8 ×= mass flowcurrent mass flowreference -----------------------------------------⎝ ⎠ ⎛ ⎞ 0.84-131 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-132 Heat Exchanger ww ThDetailed Model When you select the Detailed radio button, a summary of the rating information specified on the Rating tab appears. The Model Data group contains the following information: The Model Parameters group contains the local and overall heat transfer coefficients for the Heat Exchanger. Depending on how Figure 4.69 Field Description Tube/Shell Volume The volume of the shell and tube is calculated from the Heat Exchanger rating information. Heat Transfer Area The heat transfer area is calculated from the Heat Exchanger rating information. Elevation The elevation is significant in the calculation of static head around and in the Heat Exchanger. Shell/Tube Passes You can specify the number of tube and shell passes in the shell of the Heat Exchanger. In general, at least 2n tube passes must be specified for every n shell pass. The exception is a counter-current flow Heat Exchanger which has 1 shell pass and one tube pass Orientation The orientation may be specified as a vertical or horizontal Heat Exchanger. The orientation of the Heat Exchanger does not impact the steady state solver. However, it used in the dynamic Heat Exchanger in the calculation of liquid level in the shell. Zones per Shell Pass Enter the number of zones you would like for one shell pass. The total number of zones in a Heat Exchanger shell is calculated as: Total Zones # of Shells Zones Shell Pass ---------------------------⋅=4-132 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-133 ww Ththe Heat Transfer Coefficient Calculator is set on the Parameters page of the Rating tab, the local and overall heat transfer coefficients can either be calculated or specified in the Model Parameters group. The Startup Level group appears only if the Heat Exchanger is specified with a single shell and/or tube pass having only one zone. The Startup level cannot be set for multiple shell and/or tube pass exchangers for multiple shell or tube passes. You can specify an initial liquid level percent for the shell or tube holdups. This initial liquid level percent is used only if the simulation case re-initializes. Specs Page The Specs page contains information regarding the calculation of pressure drop across the Heat Exchanger. HT Coefficient Calculator Setting Description Shell & Tube Overall heat transfer coefficient, U, is calculated using the exchanger rating information. U Specified Overall heat transfer coefficient, U, is specified by you. The information displayed on the Specs page depends on the model (Basic or Detailed) selected on the Model page.4-133 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-134 Heat Exchanger ww ThBasic Model When you select the Basic model radio button on the Model page, the Specs page appears as follows. The pressure drop across any pass in the Heat Exchanger operation can be determined in one of two ways: • Specify the pressure drop. • Define a pressure flow relation for each pass by specifying a k value. The following parameters are used to specify the pressure drop for the Heat Exchanger. Figure 4.70 Dynamic Specification Description Shell/Tube Delta P The pressure drop across the Shell/Tube side of the Heat Exchanger may be specified (checkbox active) of calculated (checkbox inactive). k Activate this option if to have the Pressure Flow k values used in the calculation of pressure drop.4-134 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-135 ww ThEffectively, the k Reference Flow results in a more linear relationship between flow and pressure drop, and this is used to increase model stability during startup and shutdown where the flows are low. Use the Calculate k button to calculate a k value based on the Delta P and k Reference flow. Ensure that there is a non zero pressure drop across the Heat Exchanger before you click the Calculate k button. Detailed Model When you select the Basic model radio button on the Model page, the Specs page appears as follows. k Reference Flow If the pressure flow option is chosen the k value is calculated based on two criteria. If the flow of the system is larger than the k Reference Flow, the k value remains unchanged. If the flow of the system is smaller than the k Reference Flow the k value is given by: where: Factor = value is determined by HYSYS internally to take into consideration the flow and pressure drop relationship at low flow regions. At low flow range, it is recommended that the k reference flow is taken as 40% of steady state design flow for better pressure flow stability. Figure 4.71 Dynamic Specification Description kused kspecified Factor×=4-135 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-136 Heat Exchanger ww ThThe following parameters are used to specify the pressure drop for the Heat Exchanger. Clicking the K Summary button opens the Detailed Heat Model Properties property view. Holdup Page The Holdup page contains information regarding the shell and tube holdup properties, composition, and amount. Dynamic Specification Description Pressure Flow k The k-value defines the relationship between the flow through the shell or tube holdup and the pressure of the surrounding streams. You can either specify the k-value or have it calculated from the stream conditions surrounding the Heat Exchanger. you can “size” the exchanger with a k- value by clicking the Calculate K’s button. Ensure that there is a non zero pressure drop across the Heat Exchanger before the Calculate k button is clicked. Pressure Flow Option Activate this option to have the Pressure Flow k values used in the calculation of pressure drop. If the Pressure Flow option is selected, the Shell/Tube Delta P calculator must also be set to non specified. Shell/Tube Delta P The pressure drop across the Shell/Tube side of the Heat Exchanger may be specified or calculated. Shell/Tube Delta P Calculator The Shell/Tube Delta P calculator allows you to either specify or calculate the shell/tube pressure drop across the Heat Exchanger. Specify the cell with one of the following options: • Shell & Tube Delta P Calculator. The pressure drop is calculated using the Heat Exchanger rating information and correlations. • user specified. The pressure drop is specified by you. • not specified. This option is only applicable in Dynamic mode. Pressure drop across the Heat Exchanger is calculated from a pressure flow relationship. You must specify a k-value and activate the Pressure Flow option to use this calculator. Refer to Detailed Heat Model Properties section for more information. Refer to Section 1.3.3 - Holdup Page for more information. 4-136 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-137 ww ThBasic Model When you select the Basic model radio button on the Model page, the Holdup page appears as follows. The Shell Holdup group and Tube Holdup group contain information regarding the shell and tube side holdup parameters. Detailed Model When you select the Detailed model radio button on the Model page, the Holdup page appears as follows. Figure 4.72 Figure 4.734-137 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-138 Heat Exchanger ww ThThe Overall Holdup Details group contains information regarding the shell and tube side holdup parameters. The Individual Zone Holdups group contains detailed holdup properties for every layer in each zone of the Heat Exchanger unit operation. In order to view the advanced properties for individual holdups, you must first choose the individual holdup. To choose individual holdups you must specify the Zone and Layer in the corresponding drop-down lists. Stripchart Page The Stripchart page allows you to select and create default strip charts containing various variable associated to the operation. 4.4.8 HTFS-TASC Tab When you select the HTFS - Engine model on the Parameters page of the Design tab, the HTFS-TASC tab appears as shown in the figure below: Figure 4.74 Refer to Section 1.3.7 - Stripchart Page/Tab for more information.4-138 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-139 ww ThThe HTFS-TASC tab contains the following pages: • Exchanger • Process • Bundle • Nozzles • Enhanced Surfaces • Design and Material • Methods • Results The HTFS-TASC tab also contains two buttons: • Import. Allows you to import values from TASC into the pages of the tab. • Export. Allows you to export the information provided within this tab to TASC. Exchanger Page The Exchanger page allows you to input parameters that define the geometric configuration of the Heat Exchanger. After entering a basic configuration of the Heat Exchanger, you can specify detailed information. Figure 4.754-139 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-140 Heat Exchanger ww ThBasics Data For the Basics data, you can enter the following information: Entry Description Front End Head Type You can select the type of front end head for your heat exchanger using the drop-down list. The type of head selected has no significant effect on the heat exchanger thermal or pressure drop performance, as calculated by TASC. It only affects the heat exchanger weight. Shell Type You can select the type of shells for the heat exchanger using the drop-down list. Rear End Head Type You can select the type of rear end head for your heat exchanger using the drop-down list. Shell Internal Diameter You can enter the internal diameter of the shell in this cell. Tube Outside Diameter You can enter the outside diameter of the tube in this cell. Tube Length (Straight) You can enter the length of the tube in this cell. Effective Tube Count You can enter the number of tubes in the heat exchanger in this cell. If you did not enter any value in this cell, TASC derives an exact tube count while setting up the Tube Bundle Layout. Orientation You can select from three types of orientation for your heat exchanger in the drop-down list: • Default (Horiz.) • Horizontal • Vertical Hot Side You can select which side is the hot side in your heat exchanger from the drop-down list. There are three selections: • Not yet set • Tubeside hot • Shell-side hot Countercurrent in 1st Pass You can select whether countercurrent occurs in the first pass from the drop-down list. There are three selections: • Not set • Yes • No (co-current) No. Exchangers in Parallel You can specify how many heat exchangers are parallel to the current heat exchanger in this cell. No. Exchangers in Series You can specify how many heat exchangers are in series to the current heat exchanger in this cell. No. of Tubeside Passes You can specify how many tubeside passes occur in the heat exchanger in this cell. Refer to the TASC Thermal Reference guide for more information about the selections available.4-140 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-141 ww ThDetails Data For the Details data, you can enter the following information: Entry Description Tubeplate Thickness You can specify the tubeplate thickness in this cell. Shell Thickness You can specify the shell thickness in this cell. FFE/Reflux You can select the special type of exchanger using the drop-down list. There are four selections: • Default (normal) • Normal exchanger • Falling Film Evap • Reflux Condenser Fixed Head (Vert Exchgr) You can select the location of the fixed end head from the drop-down list. There are three selections: • Default/horiz • Top • Bottom The Top and Bottom selections only apply to vertical shells. Area Fraction Submerged You can enter the area fraction on the tubes that may be submerged under condensate in this cell. This value only applies to horizontal shellside condensers and if there is a lute or geometric feature that causes tubes to be submerged. M Shell Pitch You can enter the shell pitch for double-pipe U-tube exchangers or Multitube hairpin exchangers in this cell. The value is used to determine the U-bend heat transfer area. Kettle Large Shell Diameter You can enter the internal diameter of the larger part of the shell of a kettle reboiler in this cell. Weir Height Over Bundle You can enter the height of the weir above the top of the bundle in this cell. This value is used to define the head of liquid providing the driving force for re- circulation within a kettle. If no value is entered, HYSYS assumes the value is zero. The top of the weir is assumed to be level with the top of the outer tube limit circle of the bundle. Refer to the TASC Thermal Reference guide for information about the selections available.4-141 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-142 Heat Exchanger ww ThProcess Page The Process page allows you to specify the estimate pressure drop, fouling resistance, and heat load. Bundle Page The Bundle page allows you to specify the bundle, tube, and baffles configurations. The radio buttons in the Bundle Data group controls which configuration appears on the page. • Bundle • Tubes • Baffles Figure 4.76 The estimated heat load is used as a starting point to do the simulation calculation.4-142 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-143 ww ThBundle Configuration If you select the Bundle radio button in the Bundle Data group, the Bundle page appears as shown in the figure below: The configuration information you can specify for the bundle is sorted into four groups: • Size • U-Tubes • Layout • Pass Partitions Size Group The Size group allows you to specify information used to calculate the size of the bundle. Figure 4.77 Specification Description Effective Tube Count Number of tubes in the heat exchanger. The Effective Tube Count field is linked to the Effective Tube Count field on the Exchanger page. Any changes in either fields propagates to the other. No of Blocked Off Tubes Number of blocked off tubes. Bundle-Shell DIam Clear Diametral clearance between the tube bundle (outer limit diameter) and the shell wall. This value is used to determine the fraction of the shellside flow which by passes around the bundle. For zero clearance, enter 0.4-143 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-144 Heat Exchanger ww ThU-Tubes Group The U-tubes group allows you to select the configuration of the U-tubes. Layout Group The Layout group allows you to specify information used to design the layout of the bundle. First Row to Shell Specify the distance between the centres of the first row tubes to the shell. The first tube row is that nearest the inlet nozzle. Last Row to Shell Specify the distance between the centres of the last row tubes to the shell. The last tube row is that furthest from the inlet nozzle. Specification Description U-Bend Orientation You can select the type of U-bend orientation from the drop-down list. There are three selections: • Default • Horizontal • Vertical U-Bend Heat Transfer You can select whether to include or exclude the heat transfer that occurs in the U-tube using the drop-down list. There are three selections: • Default • Allow for U-bend • Ignore U-bend Specification Description Normal/Full Bundle You can select what type of bundle to use from the drop-down list. There are three selections: • Default (Normal) • Normal Bundle • Full Bundle Tubes in Window You can select whether you want tubes in the window or not from the drop-down list. There are three selections: • Default (Yes) • Yes • No Specification Description Refer to the TASC Thermal Reference guide for information about the selections available. Refer to TASC Thermal Reference guide for information about the selections available.4-144 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-145 ww ThPass Partitions Group The Pass Partitions group allows you to specify information used to configure the pass partition. Bundle Band Orientation You can select the bundle band orientation from the drop-down list. There are three selections: • Default (horizontal) • Horizontal • Vertical Tube Alignment You can select the tube alignment from the drop-down list. There are four selections: • Default (if yes 45 90) • Fully aligned • Unaligned • Part aligned Layout Symmetry You can select the layout symmetry from the drop- down list. There are four selections: • Default (sym.case 1) • Symmetry (case 1) • Symmetry (case 2) • Not enforced Pairs of Sealing Strips Number of pairs of sealing strips. Specification Description Pass Partition Layout You can select the type of pass partition from the drop- down list. There are four selections: • Not set • H Banded • Double Banded • Ribbon Banded Vertical PP Lane Width Vertical pass partition lane width. Horizontal PP Lane Width Horizontal pass partition lane width. Specification Description Refer to the TASC Thermal Reference guide for information about the selections available.4-145 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-146 Heat Exchanger ww ThTubes Configuration If you select the Tubes radio button in the Bundle Data group, the Bundle page appears as shown in the figure below: The configuration information you can specify for the tubes is sorted into two groups: • Tube Characteristics • Lengths Along Tube Tube Characteristics Group The Tube Characteristics group allows you to specify the configuration for the tube. Figure 4.78 Specification Description Tube Type You can select the type of tube you want from the drop-down lists: • Default (Plain) • Plain Tubes • Lowfin Tubes • Longitudinal Tubes Tube Outside Diameter Outside diameter of the tube. Tube Wall Thickness Thickness of the tube’s wall. Refer to the TASC Thermal Reference guide for information about the selections available.4-146 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-147 ww ThLengths Along Tube Group The Lengths Along Tube group allows you to specify the lengths of each tube section. Tube Pitch The tube’s pitch. Tube Pattern (Angle) You can select the pattern of the tube from the drop- down list: • Default (Triangular) • Triangular (30 deg) • Rotated square (45) • Roated triang. (60) • Square (90 deg) Specification Description Tube Length Length of the tube. Endlength (Front Head) Length of the front head of the tube. Endlength (Rear Head) Length of the rear head of the tube. Tube Outstand (Inlet) The distance the tube inlet end protrudes beyond the face of a tube sheet. Tube Outstand (Other) The distance the tube rear end protrudes beyond the face of a tube sheet. Central Entry/ Exit Length The distance between the centres of the Flow Baffles on either side of a central inlet or outlet nozzle. HYSYS assumes the two baffle spacings are equal if no value is entered. Dist. After Blank Baffle The distance between the tube and the blank baffle. H-Shell Central Length Length of the central region in an H-shell. This value is the distance between two halves of the axial baffle in an H-shell. HYSYS assumes the value to be double the mean length of the end spaces at the ends of the exchanger if no value is entered. Specification Description4-147 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-148 Heat Exchanger ww ThBaffles Configuration If you select the Baffles radio button in the Bundle Data group, the Bundle page appears as shown in the figure below: The configuration information you can specify for the baffles is sorted into two groups: • Baffles • Intermediate Supports Baffles Group The Baffles group allows you to specify the configuration of the baffles. Figure 4.79 Specification Description Number of Baffles Number of baffles. Baffle Type Select the baffle type from the drop-down list: • Default (Sing.Seg.) • Single Segmental • Double Segmental • Unbar/Low pr.drop • Rodbaffled Baffle Pitch The value of the baffle pitch. The baffle pitch is the baffle spacing plus the baffle thickness. Baffle Thickness The baffle thickness. Baffle Cut The percentage of baffle cut. Refer to the TASC Thermal Reference guide for information about the selections available.4-148 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-149 ww ThIntermediate Support Group The Intermediate Support group allows you to specify the tube supports, other than flow baffles, that help remove the risk of vibration damage. Nozzles Page The Nozzles page allows you to specify the nozzles in the shellside and tubeside. The radio buttons in the Side Data group controls which side appears on the page. Inner Cut (Double Seg) The percentage of inner cut. This is only applicable to Double Segmental baffle type. Baffle Cut Orientation Select the orientation of the baffle cut using the drop- down list: • Default (horizontal) • Vertical • Horizontal Diam. Clearance - Tube Diametral clearance between the tube and the baffle hole. For a zero clearance, enter 0. Diam. Clearance - Shell Diametral clearance between the baffles and the shell wall. For a zero clearance, enter 0. Specification Description Intermediate Supports (Inlet) Number of intermediate supports in the inlet endspace. This endspace corresponds to the inlet endlength. Intermediate Supports/Baffle Number of intermediate supports between each pair of flow baffles. Intermediate Supports (Return) Number of intermediate supports in the endspace corresponding to the outlet (return) endlength. U-bend Extra Supports Number of tube supports on the U-bend. Int. Supports (Central Nozzle) Number of intermediate supports for nozzles (not over inlet or return endspace). Support/Blanking Baffle Select whether there is a support of blanking baffle at the rear end head: • Default (Yes for S T) • Yes • No Longitudinal Baffle Leakage An estimate of the percentage of the shellside flow which leaks across the longitudinal baffle. This value is only relevant to the F, G, or H shell types. Specification Description Refer to the TASC Thermal Reference guide for information about the selections available.4-149 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-150 Heat Exchanger ww ThShellside Configuration If you select the Shellside radio button in the Size group, the Nozzles page appears as shown in the figure below: The following table lists and describes the configuration information that you can specify for the nozzles in shellside. Figure 4.80 Specification Description Vapour Belt Diam Clearance Diametral annular clearance (difference in diameters) between the outside of the shell and the vapour belt. Vapour Belt Slot Area The total flow area of all the slots leading through the shell wall (from the vapour belt into the shell). Vapour Belt Axial Length The axial length of the exchanger occupied by (the inside of) the belt. Impingement Plate Thickness The thickness of the impingement plate. Nozzle Function You can specify up to three types of nozzle function. Select the nozzle function from the drop- down list: • Unset • Inlet • Outlet • Intermediate • Liquid Outlet • Vapour Outlet Refer to the TASC Thermal Reference guide for information about the selections available.4-150 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-151 ww ThTubeside Configuration If you select the Tubeside radio button in the Size group, the Nozzles page appears as shown in the figure below: Nozzle Type Select the nozzle types from the drop-down list: • Default (Plain) • Plain • Plain + Imp Plate • Vapour Belt Nozzle Inside Diameter The inside diameter of the nozzle. Number In Parallel Number of nozzles in parallel on one shell. Nozzle Orientation Select the nozzle orientation from the drop-down list: • Default • Top of Shell • RHSide of Shell • Bottom of Shell • LHSide of Shell Distance to Nozzle The axial distance along the shell to the nozzle centre line, measured from the inner surface of the tubesheet at the front (fixed) head. Nozzle Wall Thickness The wall thickness of the nozzle. Figure 4.81 Specification Description4-151 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-152 Heat Exchanger ww ThThe configuration information you can specify for the nozzles in tubeside is described in the table below: Enhanced Surface Page The Enhanced Surface page allows you to perform model calculations on the exchanger that are not explicitly modeled by TASC. There are two enhanced options on the page, and you can select which enhanced option you want using the radio buttons in the Enhanced Surface Data group. Specification Description Nozzle Function You can specify up to three types of nozzle function. Select the nozzle function from the drop-down list: • Unset • Inlet • Outlet • Intermediate • Liquid Outlet • Vapour Outlet Nozzle Inside Diameter The inside diameter of the nozzle. Nozzle Orientation Select the nozzle orientation from the drop-down list: • Default • Top of Shell • RHSide of Shell • Bottom of Shell • LHSide of Shell Vel Head Lost/ FFE Inlet Number of velocity heads lost in a device (used to achieve uniform flow distribution of the liquid in-flow to all the tubes of a falling film evaporator). Nozzle Wall Thickness The wall thickness of the nozzle. Refer to the TASC Thermal Reference guide for information about the selections available.4-152 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-153 ww ThSpecific Enhanced Option If you select the Specific Enhanced radio button in the Enhanced Surface Data group, the Enhanced Surface page appears as shown in the figure below. The variables you can specify for the Specific Enhanced option are sorted into three groups: • Longitudinal Fins • Lowfin Tubes • Tube Inserts Longitudinal Fins Group The Longitudinal Fins group allows you to specify the configuration of the longitudinal fins. Figure 4.82 Specification Description Fins Per Tube Number of fins are on each tube. Fin Height Height of each fin. Fin Thickness Thickness of each fin. Fin Root Spacing The root spacing of each fin. Cut and Twist Length The cut and twist length.4-153 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-154 Heat Exchanger ww ThLowfin Tubes Group The Lowfin Tubes group allows you to specify the configuration of the lowfin tubes. Tube Inserts Group The Tube Inserts group allows you to specify the configuration of the tube inserts. Specification Description Fin Pitch The lowfin fin pitch. Fin Height The height of each fin. Fin Thickness The thickness of each fin. Root Diameter The lowfin tube root diameter. Wall Thickness The lowfin tube wall thickness. Unfinned at Baffle Length of unfinned tubing at a baffle. Specification Description Tube Insert Select the type of tube inserts from the drop-down list: • Default (plain tubes) • None (plain tubes) • Twisted tape Twisted Tape Thickness The twisted tape thickness. The value only applies if you selected twisted tape for the tube insert. 360 Degree Twisted Pitch The distance between each 360 degree twist of a twisted tape insert. Refer to the TASC Thermal Reference guide for information about the selections available.4-154 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-155 ww ThSpecific Enhanced Option If you select the General Enhanced radio button in the Enhanced Surface Data group, the Enhanced Surface page appears as shown in the figure below: The variables you can specify for the General Enhanced option is sorted into two groups: • Identity of Surface • Surface Performance Identity of Surface Group The Identity of Surface group allows you to create surfaces for both the shellside and tubeside. Figure 4.83 Specification Description Add Surface Allows you to add/create a surface. Remove Surface Allows you to remove the last surface. Name of Enhanced Surface Contains the name of the surface created. HYSYS automatically names the surface as “Set” followed by a number. The number value is incremented by 1 for each new surface created. Shellside or Tubeside Select which side the surface created on from the drop-down list: • Not used • Shellside • Tubeside Refer to the TASC Thermal Reference guide for information about the selections available.4-155 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-156 Heat Exchanger ww ThSurface Performance Group The Surface Performance group allows you to specify the configuration of each surface. Design and Material Page The Design and Material page allows you to specify design values, material types, and some properties for the Heat Exchanger. The information on this page is sorted into three groups: • Design Data • Materials • User Defined Properties Specification Description Surface Contains the list of surfaces created. Any values entered in the table located at the right of the list apply only to the surface you selected in the list. Re The Reynolds Number for the corresponding surface. f The friction factor for the corresponding surface. Cj The heat transfer factor (Colburn j factor) for the corresponding surface. Figure 4.844-156 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-157 ww ThDesign Data Group The Design Data group allows you to specify the following variables: Materials Group The Materials group allows you to select the material type for the heat exchanger. HYSYS lets you select the material for four parts of the heat exchanger: Tubes, Shell, Tubeplate, and Channel. You can select the material type from the drop-down list provided for each part. Specification Description Shellside Design Temperature Design temperature on the shellside. Shellside Design Pressure Design pressure on the shellside. Tubeside Design Temperature Design temperature on the tubeside. Tubeside Design Pressure Design pressure on the tubeside. TEMA Class Select the TEMA class from the drop-down list: • Default (R) • R • C • B • Not TEMA Crossflow Fraction for Vibration The fraction from the shellside flow in the cross flow which causes vibration. Refer to the TASC Thermal Reference guide for information about the selections available.4-157 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-158 Heat Exchanger ww ThUser Defined Properties Group The User Defined Properties group allows you to specify values for the following properties: Methods Page The Methods page allows you to specify the process methods and constraints of the heat exchanger. The Methods and Constraints group contains three radio buttons: • Process Methods • Process Constraints • Other The variables displayed on this page depend on the radio button you selected in the Methods and Constraints group. Specification Description Thermal Conductivity The thermal conductivity of the tube material. This value overrides the calculated value based on the tube material selected. Density Density for all the exchanger materials. This value overrides the calculated value based on the selected materials for each part of the exchanger. Youngs Modulus The Young’s Modulus. This value overrides the calculated value based on the tube material selected.4-158 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-159 ww ThProcess Methods Variables If you select the Process Methods radio button from the Methods and Constraints group, the Methods page appears as shown in the figure below: The table below lists the variables available for the process method: Figure 4.85 Method Description Vapour Shear Enhancement Select whether the process stream has vapour shear enhancement from the drop-down list: • Default (Yes) • Yes • No Wet Wall Desuperheating Select whether the process stream has wet wall desuperheating from the drop-down list: • Default (Yes) • Yes • No Number of Points on Curve Specify the number of points on the TASC stream heat load curve in this field. The minimum value is 6 and the maximum value is 12. Fit to Property Curve Select whether the results fit the property curve from the drop-down list: • Default • A input / calc. • Use best fit Refer to the TASC Thermal Reference guide for information about the selections available.4-159 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-160 Heat Exchanger ww ThSubcooled Boiling Select whether there is subcooled boiling from the drop-down list: • Default(ht.tr&pr.drop) • Allow in heat.tr&pr.drop • Allow in heat tran. only • Allow in press. drop only • Not allowed for Post Dryout Heat Transfer Select whether there is post dryout heat transfer from the drop-down list: • Default (allow) • Allow for • Assume Boiling Pressure Drop Calculations Select the type of pressure drop calculations from the drop-down list: • Default (fric+acc) • Frict+Acc+Gravitation • Friction+Accel HTFS Colburn- Hougen Method Select whether to apply HTFS Colburn-Hougen method from the drop-down list: • Default (no) • Yes • No Downflow Condensate Cooling Select the type of downflow condensate cooling from the drop-down list: • Default (standard) • Falling Film • Standard Method Method Description4-160 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-161 ww ThProcess Constraints Variables If you select the Process Constraints radio button from the Methods and Constraints group, the Methods page appears as shown in the figure below: The table below contains a list of the constraints available in the operation: Figure 4.86 Constraints Description Revise for Heat Balance Select the type of revise for heat balance from the drop-down list: • Default (h.load) • Heat Load • Outlet Temp. • Inlet Temp. • Flowrate Liquid Heat Transfer Coefficient Amount of liquid heat transfer coefficient. Two Phase Heat Transfer Coefficient Amount of two phase heat transfer coefficient. Vapour Heat Transfer Coefficient Amount of vapour heat transfer coefficient. Liquid Heat Transfer Coefficient Multiplier The liquid heat transfer coefficient multiplier. Two Phase Heat Transfer Coefficient Multiplier The two phase heat transfer coefficient multiplier. Vapour Heat Transfer Coefficient Multiplier The vapour heat transfer coefficient multiplier. Pressure Drop Multiplier The pressure drop multiplier. Refer to the TASC Thermal Reference guide for information about the selections available.4-161 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-162 Heat Exchanger ww ThOther Variables If you select the Other radio button from the Methods and Constraints group, the Methods page appears as shown in the figure below. The table below contains a list of variables available in the operation. Results Page The Heat Exchanger results appear on this page. The results are created in a text format that can be exported to HTFS-TASC. Figure 4.87 Variables Description Units of Output Select the type of unit for the output from the drop-down list: • Default (as Input) • SI • British/US • Metric • unused option Physical Property Package Select the type of physical property package from the drop- down list: • Default (Sep.File) • In Lineprinter O/p • Separate File • No Output Tube Layout Data Select the type of tube layout data from the drop-down list: • Default (use if available) • Use if available • Revise from input • Ignore layout data Refer to the TASC Thermal Reference guide for information about the selections available.4-162 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-163 ww Th4.5 LNG The LNG (Liquefied Natural Gas) exchanger model solves heat and material balances for multi-stream heat exchangers and heat exchanger networks. The solution method can handle a wide variety of specified and unknown variables. For the overall exchanger, you can specify various parameters, including heat leak/heat loss, UA or temperature approaches. Two solution approaches are employed; in the case of a single unknown, the solution is calculated directly from an energy balance. In the case of multiple unknowns, an iterative approach is used that attempts to determine the solution that satisfies not only the energy balance, but also any constraints, such as temperature approach or UA. The dynamic LNG exchanger model performs energy and material balances for a rating plate-fin type heat exchanger model. The dynamic LNG is characterized as having a high area density, typically allowing heat exchange even when low temperature gradients and heat transfer coefficients exist between layers in the LNG operation. Some of the major features in the dynamic LNG operation include: • A pressure-flow specification option which realistically models flow through the LNG operation according to the pressure network of the plant. Possible flow reversal situations can therefore be modeled. • A dynamic model, which accounts for energy holdup in the metal walls and material stream layers. Heat transfer between layers depends on the arrangement of streams, metal properties, and fin and bypass efficiencies. • Versatile connections between layers in a single or multiple zone LNG operation. It is possible to model cross and counter flow, and multipass flow configurations within the LNG operation. The LNG allows for multiple streams, while the heat exchanger allows only one hot side stream and one cold side stream.4-163 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-164 LNG ww Th• A heat loss model, which accounts for the convective and conductive heat transfer that occurs across the wall of the LNG operation. 4.5.1 Theory Heat Transfer The LNG calculations are based on energy balances for the hot and cold fluids. The following general relation applies any layer in the LNG unit operation. where: M = fluid flow rate in the layer = density H = enthalpy Qinternal = heat gained from the surrounding layers Qexternal = heat gained from the external surroundings V = volume shell or tube holdup LNG dynamics constructs and builds the conductive heat transfer equations into the dynamic solvers to account for the metal thermal inertia for both plates and fins. (4.37) (4.38) (4.39) M Hin Hout–( ) Qinternal Qexternal+ + ρ d VHout( ) dt ----------------------= ρ Mw Cpw× dTw dt ---------× Qin Qout–( )= Qcond k x -- A× Tw1 Tw2–( )=4-164 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-165 ww Thwhere: Mw = wall mass Cpw = wall heat capacity Tw = average wall temperature t = time Qin/Qout = the heat transfer to/from the wall Qcond = conductive heat transfer k = metal thermal conductivity x = wall thickness A = heat transfer area Tw1 and Tw2 = temperature of the two sides of the wall Pressure Drop The pressure drop across any layer in the LNG unit operation can be determined in one of two ways: • Specify the pressure drop. • Define a pressure flow relation for each layer by specifying a k-value. If the pressure flow option is chosen for pressure drop determination in the LNG, a k value is used to relate the frictional pressure loss and flow through the exchanger. This relation is similar to the general valve equation: This general flow equation uses the pressure drop across the heat exchanger without any static head contributions. The quantity, P1 - P2, is defined as the frictional pressure loss which is used to “size” the LNG with a k-value. (4.40)f density k× P1 P2–=4-165 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-166 LNG ww ThConvective (U) & Overall (UA) Heat Transfer Coefficients It is important to understand the differences between steady state and dynamics LNG models. The Steady State model is based on heat balances, and a number of specifications related to temperatures and enthalpy. In this model, the UA values are calculated based on heat curves. Whereas, the dynamic LNG model is a rating model, which means the outlet streams are determined by the physical layout of the exchanger. In steady state the order of the streams given to the LNG is not important but in the dynamics rating model the ordering of streams inside layers in each zone is an important consideration. The U value on the dynamics page of LNG refers to the convective heat transfer coefficient for that stream in contact with the metal layer. For convenience, you can also specify a UA value in Dynamic mode for each layer, and it is important to note that this value is not an overall UA value as it is in steady state but accounts merely for the convective heat transfer of the particular stream in question with its immediate surroundings. These UA values are thus not calculated in the same way as in Steady State mode. In Dynamic mode the U and UA value refers to the convective heat transfer (only) contribution between a stream and the metal that immediately surrounds it. The overall duty of each stream, in dynamic mode, is influenced by the presence of metal fins, fin efficiencies, direct heat flow between metal layers, and Several of the pages in the LNG property view indicate whether the information applies to steady state or dynamics.4-166 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-167 ww Thother factors, as it would be in a real plate-fin exchanger. Ideally in Dynamic mode the convective heat transfer coefficient, U, for each stream is specified. An initial value can be estimated from correlations commonly available in the literature or from the steady state UA values. The values specified can be manipulated by a spread sheet if desired. If the shut down and start up of the LNG is to be modeled, then the U flow scaled calculator should be selected on the Heat Transfer page, of the Rating tab, as it correctly scales the U values based on the flow. If the streams in the rating model are properly laid to optimize heat transfer (in other words, arranged in the fashion hot-cold- hot-cold and not hot-hot-cold-cold on the Model page of the Dynamics tab), and the metal resistance is not significant and significant phase change is not taking place, then the UA values reported by steady state approximates the convective UA values that can be specified in Dynamic mode for the same results. If you specify the convective UA values in Dynamic mode, than the size and metal holdup of the LNG are still considered.4-167 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-168 LNG ww ThDynamic Specifications The following table lists the minimum dynamic specifications required for the LNG unit operation to solve: 4.5.2 LNG Property View There are two ways to add a LNG Exchanger to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12 . 2. Click the Heat Transfer Equipment radio button. 3. From the list of available unit operations, select LNG. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the LNG icon. Specification Description Zone Sizing The dimensions of each zone in the LNG operation must be specified. All information in the Sizing page of the Rating tab must be completed. You can modify the number of zones in the Model page of the Dynamics tab. Layer Rating The individual layer rating parameters for each zone must be specified. All information on the Layers page of the Rating tab must be completed. Heat Transfer Specify an Overall Heat Transfer Coefficient, U, or Overall UA. These specifications can be made on the Heat Transfer page of the Rating tab. Pressure Drop Either specify an Overall Delta P or an Overall K-value for the LNG. Specify the Pressure Drop calculation method on the Specs page of the Dynamics tab. Layer Connections Every layer in each zone must be specified with one feed and one product. Complete the Connections group for each zone on the Model page of the Dynamics tab. LNG icon4-168 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-169 ww ThThe LNG property view appears. To ignore the LNG during calculations, select the Ignored checkbox. HYSYS completely disregards the operation (and cannot calculate the outlet stream) until you restore it to an active state by clearing the checkbox. 4.5.3 Design Tab The Design tab contains the following pages: • Connections • Parameters • Specs • User Variables • Notes Figure 4.884-169 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-170 LNG ww ThConnections Page The Connections page is shown in the figure below. For each exchanger side: • An inlet stream and outlet stream are required. • A Pressure Drop is required. • The Hot/Cold designation can be specified. This is used as an estimate for calculations and is also used for drawing the PFD. If a designated hot pass is actually cold (or vice versa), the operation still solves properly. The actual Hot/Cold designation (as determined by the LNG) can be found on the Side Results page. • The main flowsheet is the default shown in the flowsheet column. The LNG status appears on the bottom of the property view, regardless of which page is currently shown. It displays an appropriate message such as Under Specified, Not Converged, or OK. Figure 4.89 Any number of Sides can be added simply by clicking the Add Side button. To remove a side, select the side to be deleted and click the Delete Side button.4-170 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-171 ww ThParameters Page On the Parameters page, you have access to the exchanger parameters, heat leak/loss options, the exchanger details, and the solving behaviour. Exchanger Parameters Group In Steady State mode, you can select either an End Point or Weighted Rating Method. Figure 4.90 Parameters Description Rating Method For the Weighted method, the heating curves are broken into intervals, which then exchange energy individually. An LMTD and UA are calculated for each interval in the heat curve and summed to calculate the overall exchanger UA. Shell Passes You have the option of having HYSYS perform the calculations for Counter Current (ideal with Ft = 1.0) operation or for a specified number of shell passes. You can specify the number of shell passes to be any integer between 1 and 7. If there are more than two LNG sides, then only the Weighted rating method can be used.4-171 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-172 LNG ww ThHeat Leak/Loss Group By default, the None radio button is selected. The other two radio buttons incorporate heat loss/heat leak: Exchange Details Group The LNG Exchange Details appear as follows: For each side, the following parameters can be specified: Radio Button Description Extremes The heat loss and heat leak are considered to occur only at the end points (inlets and outlets) and are applied to the Hot and Cold Equilibrium streams. Proportional The heat loss and heat leak are applied over each interval. Heat Leak/Loss group is available only when the Rating Method is Weighted. Figure 4.91 Parameter Description Intervals The number of intervals, applicable only to the Weighted Rating Method, can be specified. For non-linear temperature profiles, more intervals are necessary. Dew/Bubble Point Select this checkbox to add a point to the Heat curve for a phase change. Figure 4.92 illustrates the effect of the number of intervals and inclusion of the dew and bubble points on the temperature / heat flow curves. Temperature is on the y-axis, and heat flow is on the x-axis Equilibrate All sides that are checked comes to thermal equilibrium before entering into the UA and LMTD calculations. If only one hot stream or cold stream is checked, then that stream is by definition in equilibrium with itself and the results are not affected. If two or more hot or cold streams are checked, then the effective driving force is reduced. All unchecked streams enter the composite curve at their respective temperatures.4-172 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-173 ww ThStep Type There are three choices, which are described below. • Equal Enthalpy. All intervals have an equal enthalpy change. • Equal Temperature. All intervals have an equal temperature change. • Auto Interval. HYSYS determines where points should be added to the heat curve. This is designed to minimize the error, using the least amount of intervals. Pressure Profile The Pressure Profile is updated in the outer iteration loop, using one of the following methods described below. • Constant dPdH. Maintains constant dPdH during update. • Constant dPdUA. Maintains constant dPdUA during update. • Constant dPdA. Maintains constant dPdA during update. This is not currently applicable to the LNG Exchanger in steady state, as the area is not predicted. • Inlet Pressure. The pressure is constant and equal to the inlet pressure. • Outlet Pressure. The pressure is constant and equal to the pressure. Parameter Description Figure 4.92 10 Intervals; Dew Bubble Points included 3 Intervals; Dew Bubble Points not included4-173 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-174 LNG ww ThSpecs Page On the Specs page, there are three groups which organize the various specification and solver information. Solver Group The Solver group includes the solving parameters used for LNG’s: Figure 4.93 Solver Parameter Specification Description Tolerance You can set the calculation error tolerance. Current Error When the current error is less than the calculation tolerance, the solution is considered to have converged. Maximum Iterations You can specify the maximum number of iteration before HYSYS stops the calculations. Iteration The current iteration of the outer loop appears. In the outer loop, the heat curve is updated and the property package calculations are performed. Non-rigorous property calculations are performed in the inner loop. Any constraints are also considered in the inner loop. Unknown Variables Displays the number of unknown variables in the LNG.4-174 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-175 ww ThUnknown Variables Group HYSYS lists all unknown LNG variables according to your specifications. Once the unit has solved, the values of these variables appear. Specifications Group Notice the Heat Balance (specified at 0 kJ/h) is considered to be a constraint. This is a Duty Error spec; if you turn it off, the heat equation cannot balance. Without the Heat Balance spec, you can, for example, completely specify all four heat exchanger streams, and have HYSYS calculate the Heat Balance error, which would be displayed in the Current Value column of the Specifications group. You can view or delete selected specifications by using the buttons that align the right of the group. A specification property view appears automatically each time a new spec is created via the Add button. Constraints Displays the number specifications you have placed on the LNG. Degrees of Freedom Displays the number of Degrees of Freedom on the LNG. To help reach the desired solution, unknown parameters (flows, temperatures) can be manipulated in the attached streams. Each parameter specification reduces the Degrees of Freedom by one. The number of Constraints (specs) must equal the number of Unknown Variables. When this is the case, the Degrees of Freedom is equal to zero, and a solution is calculated. The Heat Balance specification is a default LNG specification that must be active for the heat equation to balance. Solver Parameter Specification Description 4-175 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-176 LNG ww ThIn the figure below is a typical property view of a specification, which is accessed via the View or Add button. Each specification property view has two tabs: • Parameters • Summary The Summary page is used to define whether the specification is Active or an Estimate. The Spec Value is also shown on this page. Figure 4.94 Information specified on the Summary page of the specification property view also appears in the Specifications group. As an example, defining the Delta Temp Spec requires two stream names, and a value for the specification.4-176 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-177 ww ThAll specifications are one of the following three types: The specification list allows you to try different combinations of the above three specification types. For example, suppose you have a number of specifications, and you want to determine which ones should be active, which should be estimates and which ones should be ignored altogether. By manipulating the checkboxes among various specifications, you can test various combinations of the three types to see their effect on the results. The available specification types are: Specification Type Action Active An active specification is one which the convergence algorithm is trying to meet. Notice an active specification always serves as an initial estimate (when the Active checkbox is selected, HYSYS automatically selects the Estimate checkbox). An active specification exhausts one degree of freedom. An Active specification is one which the convergence algorithm is trying to meet. Both checkboxes are selected for this specification. Estimate An estimate is considered an Inactive specification because the convergence algorithm is not trying to satisfy it. To use a specification as an estimate only, clear the Active checkbox. The value then serves only as an initial estimate for the convergence algorithm. An estimate does not use an available degree of freedom. An Estimate is used as an “initial guess” for the convergence algorithm, and is considered to be an Inactive specification. Completely Inactive To disregard the value of a specification entirely during convergence, clear both the Active and Estimate checkboxes. By ignoring rather than deleting a specification, it is available if you want to use it later or simply view its current value. A Completely Inactive specification is one which is ignored completely by the convergence algorithm, but can be made Active or an Estimate at a later time. Specification Description Temperature The temperature of any stream attached to the LNG. The hot or cold inlet equilibrium temperature can also be defined. Delta Temp The temperature difference at the inlet or outlet between any two streams attached to the LNG. The hot or cold inlet equilibrium temperatures can also be used.4-177 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-178 LNG ww ThUser Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. Minimum Approach The minimum temperature difference between the specified pass and the opposite composite curve. For example, if you select a cold pass, this is the minimum temperature difference between that cold pass and the hot composite curve. • The Hot Inlet Equilibrium temperature is the temperature of the inlet hot stream minus the heat loss temperature drop. • The Cold Inlet Equilibrium temperature is the temperature of the inlet cold stream plus the heat leak temperature rise. UA The overall UA (product of overall heat transfer coefficient and heat transfer area). LMTD The overall log mean temperature difference. It is calculated in terms of the temperature approaches (terminal temperature differences) in the exchanger. See Equation (4.41). Duty The overall duty, duty error, heat leak or heat loss. The duty error should normally be specified as 0 so that the heat balance is satisfied. The heat leak and heat loss are available as specifications only if Heat Loss/Leak is set to Extremes or Proportional on the Parameters page. Duty Ratio A duty ratio can be specified between any two of the following duties: overall, error, heat loss, heat leak or any pass duty. Flow The flowrate of any attached stream (molar, mass or liquid volume). Flow Ratio The ratio of any two inlet stream flowrates. Specification Description For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.4-178 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-179 ww Th4.5.4 Rating Tab The Rating tab contains the following pages: • Sizing (dynamics) • Layers (dynamics) • Heat Transfer (dynamics) Sizing (dynamics) Page On the Sizing (dynamics) page, you can specify the geometry of each zone in the LNG unit operation. You can partition the exchanger into a number of zones along its length. Each zone features a stacking pattern with one feed and one product connected to each representative layer in the pattern. In practice, a plate-fin heat exchanger may have a repeating pattern of layers in a single exchanger block. A set is defined as a single pattern of layers that are repeated over the height of an While working exclusively in Steady State mode, you are not required to change any information on the pages accessible through this tab. Figure 4.954-179 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-180 LNG ww Thexchanger block. Each zone can be characterized with a multiple number of sets each with the same repeating pattern of layers. The figure below displays an LNG exchanger block (zone) with 3 sets, each containing 3 layers: The Zone Sizing and Configuration group contains information regarding the geometry, heat transfer properties, and configuration of each zone in the LNG unit operation. To edit a zone, select the individual zone in Zone group, and make the necessary changes to the other groups. The Zone Geometry group displays the following information regarding the dimensions of each zone: • Width • Length This length refers to the actual length of the exchanger, which is used for heat transfer. The remainder is taken up by the flow distributors. The flow of material travels in the direction of the Figure 4.964-180 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-181 ww Thlength of the exchanger block. The fins within each layer are situated across the width of the exchanger block. The Zone Metal Properties group contains information regarding the metal heat transfer properties: • Thermal Conductivity • Specific Heat Capacity, Cp • Density The Zone Layers group contains the following information regarding the configuration of layers in the zone: • Number of Layers in a Set • Repeated Sets Layers (dynamic) Page The Layers (dynamics) page contains information regarding the plate and fin geometry: Figure 4.97 The Copy First Layer Properties to All button can be clicked if you want to specify all the layers in the zone with the same plate and fin properties.4-181 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-182 LNG ww ThEach of the following plate and fin properties should be specified for every layer in each zone if the LNG operation is to solve: Heat Transfer (dynamics) Page The Heat Transfer (dynamics) page displays the heat transfer coefficients associated with the individual layers of the LNG unit operation. You can select internal or external heat transfer by selecting the appropriate Heat Transfer radio button. HYSYS accounts for the heating and cooling of the metal fins and plates in the LNG unit operation. The calculation of heat accumulation in the metal is based on the conductive heat transfer properties, fin efficiencies, and various other correction factors. An initial metal temperature can be specified for each zone in the Initial Metal Temperature field. Since a repeating stacking pattern is used, the top most layer of a set is assumed to exchange heat with the bottom layer of the set above. You can also select the Brazed Aluminum Plate-Fin heat transfer calculation standards by selecting the Calculate fin area using the standards of the Brazed Aluminium Plate-Fin HX Manufacturer’s Association checkbox. Select the Auto Prevent Temp. Cross checkbox to enter two parameters for split steps, and prevent the temperature from crossing along the heat transfer passes. Plate and Fin Property Description Fin Perforation The perforation percentage represents the area of perforation relative to the total fin area. Increasing the Fin Perforation decreases the heat transfer area. Height The height of the individual layers. This affects the volume of each layer holdup. Pitch The pitch is defined as the fin density of each layer. The pitch can be defined as the number of fins per unit width of layer. Fin thickness The thickness of the fin in the layer. Plate thickness The thickness of the plate.4-182 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-183 ww ThSelect the Automatically Update k’s checkbox to automatically update the k’s based on current relationships between P-F flow rates and pressure drops for all the heat transfer layers, making the LNG steam flow rates more stable. LNG Temperature Crossing Project The LNG Temperature Crossing Project redistributes the zone length fractions among the total flow pass length and multiple zones to prevent the temperature from crossing along the heat transfer passes. It uses a cascade of lumping heat zones to incorporate the distributed systems, and requires at least 10 zones to automatically remove the big temperature wiggle profiles within the flow passes. Under certain conditions, such as zone number and the changes in temperature and flow rates, the original function of Auto Prevent Temp Cross could smooth the small temperature waves. But it also made the dynamic processes unstable. To minimize temperature and flow instability in the LNG dynamic processes: 1. Specify 10 or more heat zones to remove the wiggle temperature profiles. 2. Select the Automatically Update k’s checkbox to make the LNG flow rates more stable if your LNG flow rates are not too small. 3. Select the Auto Prevent Temp Cross checkbox to prevent temperature cross and lessen small temperature waves . 4. Use the following parameters for the Auto Prevent Temperature Crossing: • Reach small split steps - A smaller value (0.001-1000) helps to prevent small temperature crossing. • Reach even split steps - A small value (0.1-1000) leads to a quick speed. Figure 4.984-183 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-184 LNG ww ThInternal Heat Transfer If you select the Internal radio button, the internal heat transfer coefficient associated with each layer appears as shown in the figure below. Currently, the internal heat transfer coefficient, U, or the overall UA must be specified for the LNG unit operation. HYSYS cannot calculate the heat transfer coefficient from the geometry/ configuration of the plates and fins. The Internal Heat Transfer group contains the following parameters: Figure 4.99 Parameter Description U Calculator The heat transfer calculator currently available in HYSYS are U specified and U flow scaled. If U specified is selected, you must specify the internal heat transfer coefficient, U. Alternatively, you can select U flow scaled calculator and a reference flow rate is used to calculate U. If you are modeling a shut-down or a start-up LNG process, select U flow scaled calculator to correctly scale the U values based on the flow condition. U The internal heat transfer coefficient is specified in this cell. Ref. Flow The Reference Flow is used to calculate U when the U Flow Scaled calculator is selected. Min Scale The minimum scale factor is applied to U by the U Flow Scaled calculator when the flow changes.4-184 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-185 ww ThExternal Heat Transfer If you select the External radio button, the overall UA associated with heat loss to the atmosphere appears. Like the internal heat transfer coefficients, the external overall UA must be specified.The External Heat Transfer group contains the following parameters: Override UA The overall UA can be specified if the Override UA checkbox is selected. The specified UA value is used without the consideration or back calculation of the internal heat transfer coefficient, U. Convective UA The overall UA is specified in this cell. Figure 4.100 Parameter Description External T The ambient temperature surrounding the plate-fin heat exchanger. This parameter may be specified or can remain at its default value. UA The overall UA is specified in this field. The heat gained from the ambient conditions is calculated using the overall UA. Parameter Description4-185 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-186 LNG ww Th4.5.5 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the LNG unit operation. 4.5.6 Performance Tab The Performance tab contains detail performance results of the LNG exchanger. The calculated results are displayed in the following pages: • Results (SS). Contains information relevant only to Steady State mode. • Plots (SS/Dyn). Contains information relevant to both Steady State and Dynamics mode. • Tables (SS). Contains information relevant only to Steady State mode. • Summary (dynamics). Contains information relevant only to Dynamics mode. • Layers (dynamics). Contains information relevant only to Dynamics mode. Q1 Q1 is calculated from the overall UA and the ambient temperature. If heat is gained in the holdup, Q1 is positive; if heat is lost, Q1 is negative. Qfixed A fixed heat value can be added to each layer in the LNG unit operation. Since Qfixed does not vary, a constant heat source or sink is implied (for example, electrical tracing). If heat is gained in the holdup, Qfixed is positive; if heat is lost, Qfixed is negative. The PF Specs page is relevant to dynamics cases only. Parameter Description Refer to Section 1.3.10 - Worksheet Tab for more information.4-186 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-187 ww ThResults Page The Results page displays the calculated values generated by HYSYS. These values are split into three groups for your convenience. Overall Performance Group Figure 4.101 Parameter Description Duty Combined heat flow from the hot streams to the cold streams minus the heat loss. Conversely, this is the heat flow to the cold streams minus the heat leak. Heat Leak Loss of cold side duty to leakage. Heat Loss Loss of hot side duty to leakage. UA Product of the Overall Heat Transfer Coefficient and the Total Area available for heat transfer. The LNG Exchanger duty is proportional to the overall log mean temperature difference, where UA is the proportionality factor. That is, the UA is equal to the overall duty divided by the LMTD. Minimum Approach The minimum temperature difference between the hot and cold composite curves. LMTD The LMTD is calculated in terms of the temperature approaches (terminal temperature differences) in the exchanger, using Equation (4.41).4-187 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-188 LNG ww ThThe equation used to calculate LMTD is: where: Detailed Performance Group Side Results Group The Side Results group displays information on each Pass. For each side, the inlet and outlet temperatures, molar flow, duty, UA, and the hot/cold designation appear. (4.41) Parameter Description Estimated UA Curvature Error The LMTD is ordinarily calculated using constant heat capacity. An LMTD can also be calculated using linear heat capacity. In either case, a different UA is predicted. The UA Curvature Error reflects the difference between these UAs. Hot Pinch Temperature The hot stream temperature at the minimum approach between composite curves. Cold Pinch Temperature The cold stream temperature at the minimum approach between composite curves. Cold Inlet Equilibrium Temperature The Equilibrium Temperature for the cold streams. When streams are not equilibrated (see the Parameters page), the Equilibrium temperature is the coldest temperature of all cold inlet streams. Hot Inlet Equilibrium Temperature The Equilibrium Temperature for the hot streams. When streams are not equilibrated (see the Parameters Page), the Equilibrium temperature is the hottest temperature of all hot inlet streams. ΔTLM ΔT1 ΔT2– ΔT1 ΔT2⁄( )ln ---------------------------------= ΔT1 Thot out, Tcold in,–= ΔT2 Thot in, Tcold o, ut–=4-188 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-189 ww ThPlots Page On the Plots page, you can plot composite curves or individual pass curves for the LNG. The options available on this page varies, depending on the type of mode (Steady State or Dynamics) your simulation case is in. Use the checkboxes under the Plot column to select which curve(s) you want to appear in the plot. • In Steady State mode, all the checkboxes under the Plots column are active. • In Dynamics mode, the Cold Composite and Hot Composite checkboxes are unavailable. The data displayed in the plot varies depending on the simulation mode: • In Steady State mode, the information in the plot is controlled by the selection in the Plot Type drop-down list. Figure 4.102 You can modify the appearance of the plot via the Graph Control property view. The Plot Type drop-down list is only available at Steady State mode. Refer to Section 1.3.1 - Graph Control Property View for more information.4-189 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-190 LNG ww ThThe Plot Type drop-down list enables you to select any combination of the following data for the x and y axes: Temperature, UA, Delta T, Enthalpy, Pressure, and Heat Flow. • In the Dynamics mode, the plot only displays the Temperature vs. Zone data. Use the View Plot button to open the plot area in a separate property view. Tables Page On the Table page, you can examine the interval Temperature, Pressure, Heat Flow, Enthalpy, UA, Vapour Fraction, and Delta T for each side of the Exchanger in a tabular format. Choose the side, Cold Composite or Hot Composite, by making a selection from the Side drop-down list located above the table. Summary Page The Summary page displays the results of the dynamic LNG unit operation calculations. On this page, the following zone properties appear for each layer: • Layer • Inlet Temperature Figure 4.1034-190 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-191 ww Th• Exit Temperature • Inlet Enthalpy • Exit Enthalpy • Inlet Flow rate • Outlet Flow rate • Fluid Duty • Fluid Volume • Surface Area • Metal Mass The Fluid Duty is defined as the energy specified to the holdup. If the fluid duty is positive, the layer gains energy from its surroundings; if the fluid duty is negative, the layer loses energy to its surroundings. Layers Page The Layers page displays information regarding local heat transfer and fluid properties at endpoint locations in each layer of each zone. If the Combine Layers checkbox is selected in the Model page of the Dynamics tab, some parameters in the Summary page of the Performance tab include contributions from multiple layers. Figure 4.1044-191 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-192 LNG ww ThUse the Zone, Layer, and Point drop-down list to select the zone, layer, and endpoint location you want to see. Click the Diagram button to access the Layer Point Conditions property view. Layer Point Conditions Property View The Layer Point Conditions property view displays the detailed temperatures and overall heat transfer values for both endpoints of the selected layer. You can select a different layer using the Layer drop-down list. Click the View Holdup button to access the Holdup property view. The information displayed on this page is not central to the performance of the LNG operation. Figure 4.105 Indicates the flow direction in the selected layer. Refer to Section 1.3.4 - HoldUp Property View for more information.4-192 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-193 ww Th4.5.7 Dynamics Tab The Dynamics tab contains the following pages: • Model • Specs • Holdup • Estimates • Stripchart Model Page On the Model page, you can specify how each layer in a multi- zone LNG unit operation is connected. If you are working exclusively in steady state mode, you are not required to change any information on the pages accessible through this tab. Figure 4.1064-193 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-194 LNG ww ThMain Settings The Main Settings group displays the following LNG model parameters: The Connections group displays the feed and product streams of each layer for every zone in the LNG unit operation. Every layer must have one feed stream and one product stream in order for the LNG operation to solve. A layer’s feed or product stream can originate internally (from another layer) or externally (from a material stream in the simulation flowsheet). Thus, various different connections can be made allowing for the modeling of multi-pass streams in a single zone. Parameter Description Number of Zones The number of zones in a LNG unit operation can be specified in this field. Elevation You can specify the elevation of the LNG in this field. The elevation is significant in the calculation of static head in and around the LNG unit operation. Combine Layers Checkbox With the Combine Layers checkbox selected, individual layers (holdups) carrying the same stream in a single zone is calculated using a single holdup. The Combine Layers option increases the speed of the dynamic solver, and usually yields results that are similar to a case not using the option. Figure 4.1074-194 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-195 ww ThConnections Group Every zone in the LNG unit operation is listed in the Zone drop- down list in the Connections group. All the layers in the selected zone in one set appear. For every layer’s feed and product, you must specify one of the following: • An external material stream. • The zone and layer of an internal inlet or exit stream. You can specify the relative direction of flow in each layer in the zone. Layers can flow counter (in the opposite direction) or across the direction of a reference stream. The reference stream is defined as a stream which does not have either the Counter or Cross checkbox selected in the Connections group. The following table lists three possible flow configurations: Description Flow Direction Flow Setting Counter Current Flow Parallel Flow Cross Flow To implement counter current flow for two streams in a single exchanger block, ensure that the Counter checkbox is selected for only one of the streams. If the Counter checkbox is selected for both streams, the flow configuration is still parallel, and in the opposite direction.4-195 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-196 LNG ww ThSpecs Page The Specs page contains information regarding the calculation of pressure drop across the LNG unit operation. The following parameters appear for every layer in each zone in the LNG unit operation in the Dynamic Specification groups. Figure 4.108 Dynamic Specification Description Delta P Calculator The Delta P Calculator allows you to either specify or calculate the pressure drop across the layer in the LNG operation. Specify the cell with one of following options: • user specified. You specify the pressure drop. • not specified. Pressure drop across the layer is calculated from a pressure flow relationship. You must specify a k-value, and select the Flow Eqn checkbox if you want to use this non specified Delta P calculator. Delta P The pressure drop across the layer of the LNG operation can be specified or calculated. Flow eqn Activate this option, if you want to have the Pressure Flow k value used in the calculation of pressure drop. If the Flow Eqn checkbox is selected, the Delta P calculator must also be set to not specified. 4-196 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-197 ww ThWhen you click the Generate Estimates button, the initial pressure flow conditions for each layer are calculated. HYSYS generates estimates using the assumption that the flow of a particular stream entering the exchanger block (zone) is distributed equally among the layers. The generated estimates appear on the Estimates page of the Dynamics tab. It is necessary to complete the Estimates page in order for the LNG unit operation to solve. It is strongly recommended that you specify the same pressure drop calculator for layers that are connected together in the same exchanger block or across adjacent exchanger blocks. Complications arise in the pressure flow solver if a stream’s flow is set in one layer, and calculated in the neighbouring layer. The Automatically Update k’s checkbox automatically updates the k’s based on current relationships between P-F flow rates and pressure drops for all the heat transfer layers, making the LNG steam flow rates more stable. Laminar HYSYS is able to model laminar flow conditions in the layer. Select the Laminar checkbox if the flow through the layer is in the laminar flow regime. Pressure Flow k Value The k-value defines the relationship between the flow through layer and the pressure of the surrounding streams. You can either specify the k-value or have it calculated from the stream conditions surrounding the layer. You can “size” each layer in the zone with a k-value by clicking the Calculate k’s button. Ensure that there is a non zero pressure drop across the LNG layer before the Calculate k button is clicked. Each zone layer can be specified with a flow and set pressure drop by clicking the Generate Estimates button. The LNG unit operation, like other dynamic unit operations, should use the k-value specification option as much as possible to simulate actual pressure flow relations in the plant. Dynamic Specification Description4-197 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-198 LNG ww ThHoldup Page The Holdup page contains information regarding each layer’s holdup properties, composition, and amount. The Details group contains detailed holdup properties for every layer in each zone of the LNG. In order to view the advanced properties for individual holdups, you must first select the individual holdup. To choose individual holdups you must specify the Zone and Layer in the corresponding drop-down lists. Figure 4.109 Refer to Section 1.3.3 - Holdup Page for more information. 4-198 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-199 ww ThEstimates Page The Estimates page contains pressure flow information surrounding each layer in the LNG unit operation: The following pressure flow information appears on the Estimates page: • Delta P • Inlet Pressure • Outlet Pressure • Inlet Flow • Outlet Flow It is necessary to complete the Estimates page in order for the LNG unit operation to completely solve. The simplest method of specifying the Estimates page with pressure flow values is having HYSYS estimate these values for you. This is achieved by clicking the Generate Estimates button on the Specs page of the Dynamics tab. HYSYS generates estimates using the assumption that the flow of a particular stream entering the exchanger block (zone) is distributed equally among the layers. Stripchart Page The Stripchart page allows you to select and create default strip charts containing various variable associated to the operation. Figure 4.110 Refer to Section 1.3.7 - Stripchart Page/Tab for more information.4-199 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-200 LNG ww Th4.5.8 HTFS-MUSE Tab The HTFS-MUSE tab integrates the HTFS’ MUSE application into the HYSYS LNG unit Calculation. HYSYS can use the MUSE and MULE calculation Engines. MUSE can perform a range of calculations on plate-fin heat exchangers, either simple two-stream exchangers, or complex ones with multiple streams. The basic calculation options are described in the table below: These calculation types all relate to co- or counter-current exchangers. The HTFS-MUSE tab contains two buttons: • Import. Allows you to import values from MUSE into the pages of the tab. • Export. Allows you to export the information provided within this tab to MUSE. Calculation Modes Description Simulation Determines the heat load, pressure changes and outlet conditions for each stream in the exchanger, based on an exchanger you specify, and given stream inlet conditions. Layer by Layer Simulation For the simulation of a plate fin heat exchanger on a layer by layer basis. It must be specified with a layer pattern. It predicts temperature profiles through the layer pattern, which can be used to assess how good the layer pattern is. Thermosyphon Determines the performance of an exchanger, with a geometry you specify, with one stream operating as a thermosyphon. The exchanger can either be internal to the column or outside it and connected via pipe work. You can specify either the head of liquid driving the thermosyphon flow, or the thermosyphon stream flowrate, leaving the program to calculate the one you do not specify. Design Produces a “first shot” design of a heat exchanger to meet a heat load duty and pressure drop limits, which you specify for each stream. This should be a useful indication of what a specialist manufacturer would provide. A final design of a plate-fin exchanger must, however, come from a manufacturer, who can use proprietary finning and specialist design and manufacturing techniques.4-200 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-201 ww ThThe HTFS-MUSE tab contains the following pages: • Exchanger • Process • Distributors • Layer Pattern • Fins • Design Limits • Stream Details • Methods • Results Exchanger Page The Exchanger page allows you to specify parameters that define the geometric configuration of the exchanger, as well as the stream. Figure 4.1114-201 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-202 LNG ww ThThe group located on the top of the page is for specifying the stream geometry and consists of the following fields: The remainder of the groups located on this page are for specifying the exchangers geometry and consists of the following fields: Field Description Flow Direction There are two options that you can choose from to define the Flow direction of the stream. • flow away from end A, Up (B to A). • flow towards end A, Down (A to B). Normal design practice is for hot streams to flow away from end A (which is at the top of the exchanger), while cold streams flow towards end A. Number of Layers Allows you to enter the total number of layers a stream occupies in the exchanger. If there is more than one exchanger in parallel, enter the number for one exchanger only. This item can be omitted if a layer pattern is specified. If you specify both, however, they are cross-checked, which can be useful in detecting errors in a layer pattern input. When they are inconsistent, a warning is produced. If a stream is re-distributed, and occupies extra layers for part of its length, enter the basic number of layers only here, and specify the additional layers on the Distributors page. Distance to Start of Main Fin Allows you to enter the distance to the start of a stream's main finning from the fixed reference point. If omitted, the default is zero. If this distance is less than the distance to the start of the effective length, then there is a region of main fin where pressure drop, but no heat transfer is evaluated. If this distance is greater than that to the start of the effective length, then the stream has a draw-on or draw-off point part way along the exchanger. Field Description Orientation Plate Fin heat exchangers are normally vertical, with flow up or down. Enter 1.0 for vertical exchangers with the reference end, A, at the top. For horizontal or inclined exchangers, refer to the MUSE help file. Exchangers in Parallel More than one exchanger in parallel can be used when stream flowrates, or thermal duties are too large to be handled by a single exchanger. In all cases the exchangers are assumed to be identical, and no calculations are performed on pressure losses in connecting pipe work. Effective Width The effective flow width is the total width of the exchanger less the widths of the two side bars.4-202 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-203 ww ThProcess Page Exchanger Metal Plate Fin exchangers for LNG and other cryogenic duties are made of aluminium. For other exchangers, you can select from: • aluminium • stainless steel • titanium Parting Sheet Thickness The thickness of the separating plates (parting sheets) between layers is used to determine the exchanger stack height, and also has an effect on the metal resistance to heat transfer. Side Bar Width Side bars form the sides and ends of each layer. This item does not usually affect the calculated results, with the exception of longitudinal conduction calculations. Cap Sheet Thickness The stack height is the sum of the fin heights and parting sheet thicknesses for every layer in the exchanger, plus the thickness of the two side plates (cap sheets). Fin Number for Empty Layer If you specify a layer pattern with some layers containing no streams enter the fin number to identify the fins used in such layers. Figure 4.112 Field Description4-203 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-204 LNG ww ThThe Process page allows you to specify the following process information for the streams attached to your exchanger: • Estimated Pressure Drop • Fouling Resistance • Heat Load • Design Pressure Distributors Page Distributors are special regions of finning, usually laid at an angle, that directs the flow between a header (inlet or outlet) and the main heat transfer finning. A low frequency perforated fin is usually used - for example 6fpi, 25% perforated. Distributor data is optional for each stream. If omitted the distributor pressure drop for that stream is ignored. Heat transfer in inlet and outlet distributors is not considered, but if all streams have distributor data specified, an estimate is made of the heat transfer margin associated with each distributor. When distributor pressure drops are calculated, an estimate is made of the risk of maldistribution across the width of each layer. When Redistribution is used, you should specify the Redistributor, and corresponding re-inlet distributor. Redistributors associated with partial draw-off of streams can also be specified. 4-204 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-205 ww ThEach distributor type consists of a set of inputs as shown in the figure below. • Inlet/Outlet Distributor Type Figure 4.113 Field Description Type Allows you to specify the redistributor type, and the side of the exchanger on which the associated header is located. You have seven options: • Full End • End-Side • Central • Diagonal • Mitred • Indirect • Hardway Header Location Allows you to specify the side of the exchanger that the header is located. You have four options: • Right side • Left side • Central • Twin Fin Number for Pad 1 and 2 Numbers to identify the fins used in the inlet/outlet distributor pads. Distributors typically use 6fpi 255 perforated finning. The same fin is usually used in both pads, so only pad 1 need normally be specified. Pad 1 is adjacent to the header. Dimension a (axial length) Dimension a for the inlet/outlet distributor. Dimension a is the length along the exchanger occupied by the distributor.4-205 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-206 LNG ww Th• Redistributor Type Dimension b Dimension b for the inlet/outlet distributor. This is the header diameter for End Side, Central, Indirect and Hardway distributors, and the Pad 1 length for Mitred distributors. It is not needed for Full End of Diagonal distributors. Nozzle DIameter The internal diameter of the inlet/outlet nozzle. If omitted the inlet/outlet nozzle pressure loss is not calculated. Field Description Type Allows you to specify the redistributor type, and the side of the exchanger on which the associated header is located. You have four options: • Standard • Twin • Hardway • Hardway Twin Header Location Allows you to specify the side of the exchanger that the header is located. You have three options: • Right side • Left side • Twin Distance to Redistributor Allows you to specify the distance to the redistributor from the inlet. Fin Number for Pad 1, 2, and 3 Numbers to identify the fins used in the redistributor. The same fin is usually used in all pads, so only pad 1 need normally be specified. In a dividing redistributor, flow that remains in the layers flows through Pad 1 then Pad 2, while Pad 3 carries the flow that goes to other layers. Dimension a (axial length) Dimension a, the length along the exchanger occupied by the redistributor. Dimension b Dimension b for the redistributor. In a conventional dividing redistributor, this is the entry width associated with the flow that remains in the same layer. Field Description4-206 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-207 ww Th• Re-Inlet Distributor Type Layer Pattern Page The Layer Pattern page allows you to define the sequence of stream numbers that comprise the exchanger. Field Description Type Allows you to specify the re-inlet distributor type. This can be in any form of side entry/exit distributor. You have five options: • None • Diagonal • Mitred • Indirect • Hardway Fin Number for Pad 1 and 2 Numbers to identify the fins used in the re-inlet distributor pads. The same fin is usually used in both pads, so only pad 1 need normally be specified. Pad 1 is adjacent to the header. Dimension a (axial length) Dimension a, the length along the exchanger occupied by the re- inlet distributor. Dimension b Dimension b for the re-inlet distributor. Extra Layers/ Draw Off Fraction For a re-inlet distributor that directs flow to a number of extra layers, enter the number of extra layers. For a re-inlet distributor that collects from the extra layers, to direct it back to the basic number of layers, enter the number of extra layers with a minus sign. If there are no extra layers, but the stream is partially drawn off, enter the fraction of the stream that is drawn off. Figure 4.1144-207 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-208 LNG ww ThThe layer pattern itself gives the sequence of layers, while the Layer Definition table lets you define the sequence of streams in each layer. The layer pattern is mandatory input for Layer-by- Layer simulations, but optional for stream by stream. If no layer pattern is provided, the number of layers for each stream must be specified. Layer Pattern Enter the sequence of layers forming the layer pattern (stacking pattern). The pattern can be identified as a sequence of layer identifiers, each identified by a letter, such as ABABABCAB. Though in simple cases, for example when there is only one stream per layer, the layer pattern can be specified as sequence of streams, for example 121213412. Repeated sequences can be written in brackets, for example (121213/5)1312 means that the sequence 121213 occurs five times, followed by 1312. Spaces in the pattern are ignored, and brackets cannot be embedded in brackets. A stream number’s sequence can contain zeros to indicate completely empty layers. A layer pattern can terminate in M or MM to indicate that the pattern has central symmetry. MM indicates that the central layer is repeated, M that the symmetry is about the centre of the final layer. When The pattern is defined in terms of letters, use | or ||, not M's, to indicate mirror symmetry. Layer Definition For each (alphabetic) layer identifier in the pattern specify the stream or sequence of streams along the exchanger from end A, within each layer type. This is only needed when a pattern is defined in terms of layer types (A, B, C, and so forth) rather than streams (1, 2, 4, and so forth). The Layer Definition facility is only available in MUSE 3.20 and later versions.4-208 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-209 ww ThFins Page The Fins page allows you to specify data on fin geometry. When a fin is specified, the corresponding fin performance data from the fin manufacturer (friction factors and Colburn j factors over a range of Reynolds numbers) should be input when available. If they are not available, they are estimated using generalized HTFS correlations for particular fin types. Fin numbers are used to identify the particular fin used as main fin or distributor fin for each stream. Fin numbers up to 20 identify fins that data is specified in the program input. The Fin Geometry groups consists of two buttons and a table. The two buttons allows you to add and remove fins from the heat exchanger, while the table allows you to specify each fin’s geometry. Figure 4.1154-209 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-210 LNG ww ThThe table consists of the following fields. As mentioned above the corresponding fin performance data from the fin manufacturer, if available, should be entered into the Fin Performance group. To specify the data, select the fin number from the list of fins, and enter the data in the appropriate fields. Field Description Fin Type There are four main types of fin • Plain • Perforated • Serrated, or offset-strip • Wavy or herringbone For details of when each type should be used, refer to the MUSE Help file. Prandtl No. Correlation to Cj This parameter is important for high viscosity fluids in plain or perforated fins. The Colburn j factor assumes that Cj is a function of Re only, but this is not true at low Reynolds numbers (below 1000), where there is also Prandtl number dependence. If you specify the Re-f-Cj data at a Pr appropriate to the fluids used, omit this item. If you specify the Pr=1 data, specify 1 for a full correction, or a value between 0 and 1 for a partial correction. Refer to the MUSE Help file for more details. Fin Height Distance between the separating plates (parting sheets). This applies to all fin types. All the fins (main fin and distributor) for a stream must have the same height. A warning is issued if this is not so. Fin Thickness The fin thickness. Fin Frequency Number of fins per unit of length. This item can be zero if no fins are present. Common fin frequencies are 16, 18 or 21 ft/in for main fins, and 6 or 8 ft/in for distributor fins. Fin Porosity For perforated fins, enter the fin porosity as a fraction of the metal lost as holes. Fin Serration Length For serrated fins enter the fin serration length. The default is 3 mm (approximately 1/8 inch), which is typical of values used by most manufacturers. This input item is only needed for long-serration length serrated fins.4-210 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-211 ww ThDesign Limits Page In the future version of HYSYS, the HTFS design capability will be available on the Design Limits page. Stream Details Page The Stream Details page allows you to specify more stream geometry data that supplements the data that was entered on the Exchanger page. Figure 4.1164-211 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-212 LNG ww ThThe following table defines each of the fields on this page. Field Description Same Layer as Stream The Same Layer as Stream parameter is one way of specifying that two streams occupy the same set of layers in an exchanger. It is not needed, if you specify a layer pattern in terms of Layer Identifiers A, B, C, and so forth, with Layer Definition information. If you specify a layer pattern in terms of stream numbers, then one stream in each layer is used to identify that layer. For other streams in that layer give the number of the stream in the layer pattern that identifies the layer. Fraction of Double Banking The Fraction of Double Banking parameter is not needed if you specify a layer pattern, and is estimated if you do not. Refer to the MUSE Help for a definition and more details. Number of Cross Flow Passes For streams in multipass crossflow, enter the number of crossflow passes. Fin Number of (first) Main Fin Number to identify the main heat transfer fin for the stream. The number must correspond to one of the fin data blocks in the Fins page, or to a fin in a User Databank. If the stream uses more than one type of main fin, this item is the first fin, counting from the stream inlet. Length of (first) Main Fin The length of the main fin for the stream. Fin Number for Second to Sixth Fins For a stream that uses more than one type of main fin, enter the fin numbers. The sequence is from stream inlet to outlet. Length of Fins for Second to Sixth Fins The length of each main fin for the stream.4-212 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-213 ww ThMethods Page The Methods page consists of three groups: • Calculation Options • Calculation Parameters • Process Constraints Calculation Options Group The Calculation Options group is used to configure the data that appears on the Results page. Only the Output Units need normally be set, as defaults are usually acceptable for all other items. Figure 4.1174-213 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-214 LNG ww ThThe group consists of the following fields. Field Description Calculation Type The Calculation Type should not be set. It gives access to a deprecated calculation facility, Length estimation, as an alternative to Normal simulation. Refer to the MUSE help file for more information. Units of Output Allows you to specify the set of units you want to use for the output data. There are five options to choose from: • SI / deg C • British • Metric / C • SI / deg K • Metric / K Output of Input Data Specifies where the output of input data appears in the main Results page (lineprinter output). Refer to the MUSE help for more information. Physical Properties Package Allows you to send the Physical Properties of the exchanger to the Results page or to a specific file. Convergence Parameter Use only if MUSE shows convergence problems. Refer to the MUSE help for more information. Stream by Stream or Layer by Layer Normally leave this item unset. Use it only with the (MULE) layer-by-layer calculation engine to enforce a reduced stream-by-stream calculation. Refer to the MUSE help for more information. Longitudinal Conduction You can specify that in addition to heat transfer between streams, allowance can be made for heat conducted in the exchanger metal from the hot to cold end of the exchanger. This can be important for exchangers used in liquefying hydrogen or helium. Refer to the MUSE help for more information. Number of Calculation Steps Calculations in MUSE use a number of equal length steps along the exchanger. The default is 100, the maximum 200. Refer to the MUSE help file for more information. 1st Est. Heat Load (fraction of max) Use this item only if there are convergence problems. It lets you change the initial estimate of exchanger duty. Refer to the MUSE help file for more information. Distributor Calculations Gives you control over when distributor pressure losses are calculated. The default is that losses are calculated if you specify distributor data. Refer to the MUSE help for more information. Maximum Number of Iterations Enter a value if you want to restrict the number of iterations. Refer to the MUSE help file for more information.4-214 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Heat Transfer Operations 4-215 ww ThCalculation Parameters Group The Calculation Parameters group allows you to specify process exchanger parameters. The group consists of the following fields: Process Constraints Group The Process Constraints group allows you to specify sets of stream constraints for over-riding, or scaling values normally calculated by the program. These should not be used, unless you have a good reason for doing so. Field Description Heat Leak It is possible to specify a net heat leak into the exchanger, or out of the exchanger, if a negative value is specified. Heat Leak Skewness For heat leaks that are not uniform along the exchanger length. Refer to the MUSE help for more information. Effective Length, Distance to Effective Length These two fields should normally be omitted, and left to the program to calculate. The effective length is that region of the exchanger where heat transfer is assumed to occur. It is determined from the exchanger geometry data, but you can override the program if you want. Refer to the MUSE help for more information. A Stream - B Stream Load A deprecated input. It is possible to specify the heat load across the exchanger for end A to end B. Field Description Liquid Phase HTC You can enter a value for the liquid heat transfer coefficient here to override the calculated value. It is recommended that the program calculated values be used. Two Phase HTC You can enter a value for the two phase (boiling or condensing) heat transfer coefficient here to override the calculated value. It is recommended that the program calculated values be used. Vapour Phase HTC You can enter a value for the vapour heat transfer coefficient here to override the calculated value. It is recommended that the program calculated values be used.4-215 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 4-216 References ww ThResults Page The exchanger results appear on this page. The results are created in a text format that can be exported to HTFS-MUSE. 4.6 References 1 Perry, R.H. and D.W. Green. Perry’s Chemical Engineers’ Handbook (Seventh Edition) McGraw-Hill (1997) p. 11-33 2 Perry, R.H. and D.W. Green. Perry’s Chemical Engineers’ Handbook (Seventh Edition) McGraw-Hill (1997) p. 11-42 3 Kern, Donald Q. Process Heat Transfer McGraw-Hill International Editions: Chemical Engineering Series, Singapore (1965) p. 139 Multiplier for Liquid Coefficient A value entered here can be used to increase or decrease the calculated liquid heat transfer coefficient. It also scales any pre-set coefficient you input. It is recommended that the program calculated values be used. Multiplier for Two Phase Coefficient A value entered here can be used to increase or decrease the calculated boiling or condensing heat transfer coefficient. It also scales any pre-set coefficient you input. It is recommended that the program calculated values be used. Multiplier for Vapour Coefficient A value entered here can be used to increase or decrease the calculated vapour or gas heat transfer coefficient. It also scales any pre-set coefficient you input. It is recommended that the program calculated values be used. Pressure Drop Multiplier Enter the number that the calculated frictional pressure gradient (liquid, two phase or vapour) should be multiplied. It is not possible to scale the pressure drops of each phase separately. It is recommended that the program calculated values be used. Precalculated Arrays Flag Allows you to override an internal calculation flag, it is best left unset. See the MUSE help for more details. Preset deltaT for Boiling Provides a variant on the boiling method, it is best left unset. See the MUSE help for more details. Field Description4-216 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-1 ww Th5 Logical Operationsw.cadfamily.com EMa e document is for study 5.1 Adjust ............................................................................................ 4 5.1.1 Adjust Property View ................................................................ 5 5.1.2 Connections Tab....................................................................... 6 5.1.3 Parameters Tab ........................................................................ 8 5.1.4 Monitor Tab ........................................................................... 14 5.1.5 User Variables Tab.................................................................. 16 5.1.6 Starting the Adjust ................................................................. 17 5.1.7 Individual Adjust .................................................................... 18 5.1.8 Multiple Adjust....................................................................... 18 5.2 Balance ........................................................................................ 19 5.2.1 Balance Property View ............................................................ 20 5.2.2 Connections Tab..................................................................... 21 5.2.3 Parameters Tab ...................................................................... 22 5.2.4 Worksheet Tab ....................................................................... 27 5.2.5 Stripchart Tab........................................................................ 27 5.2.6 User Variables Tab.................................................................. 27 5.3 Boolean Operations...................................................................... 28 5.3.1 Boolean Logic Blocks Property View .......................................... 29 5.3.2 And Gate .............................................................................. 34 5.3.3 Or Gate ................................................................................ 35 5.3.4 Not Gate ............................................................................... 36 5.3.5 Xor Gate ............................................................................... 37 5.3.6 On Delay Gate ....................................................................... 38 5.3.7 Off Delay Gate ....................................................................... 39 5.3.8 Latch Gate ............................................................................ 40 5.3.9 Counter Up Gate .................................................................... 41 5.3.10 Counter Down Gate .............................................................. 42 5.3.11 Cause and Effect Matrix......................................................... 435-1 il:cadserv21@hotmail.com only,if tort to your rights,please inform us,we will delete 5-2 Logical Operations www.cadfamily.com EMa The document is for study 5.4 Control Ops...................................................................................56 5.4.1 Adding Control Operations........................................................56 5.4.2 Split Range Controller..............................................................58 5.4.3 Ratio Controller ......................................................................80 5.4.4 PID Controller.......................................................................101 5.4.5 MPC Controller......................................................................132 5.4.6 DMCplus Controller ...............................................................155 5.4.7 Control Valve........................................................................171 5.4.8 Control OP Port.....................................................................175 5.5 Digital Point................................................................................176 5.5.1 Digital Point Property View .....................................................176 5.5.2 Connections Tab....................................................................177 5.5.3 Parameters Tab.....................................................................178 5.5.4 Stripchart Tab.......................................................................184 5.5.5 User Variables Tab.................................................................184 5.5.6 Alarm Levels Tab...................................................................185 5.6 Parametric Unit Operation ..........................................................186 5.6.1 Parametric Unit Operation Property View ..................................187 5.6.2 Design Tab ...........................................................................187 5.6.3 Parameters Tab.....................................................................195 5.6.4 Worksheet Tab......................................................................196 5.7 Recycle .......................................................................................197 5.7.1 Recycle Property View............................................................198 5.7.2 Connections Tab....................................................................199 5.7.3 Parameters Tab.....................................................................200 5.7.4 Worksheet Tab......................................................................208 5.7.5 Monitor Tab ..........................................................................208 5.7.6 User Variables Tab.................................................................209 5.7.7 Calculations .........................................................................209 5.7.8 Reducing Convergence Time...................................................210 5.7.9 Recycle Assistant Property View ..............................................211 5.8 Selector Block.............................................................................215 5.8.1 Selector Block Property View ..................................................215 5.8.2 Connections Tab....................................................................216 5.8.3 Parameters Tab.....................................................................217 5.8.4 Monitor Tab ..........................................................................2205-2 il:cadserv21@hotmail.com only,if tort to your rights,please inform us,we will delete 5-3 Logical Operations www.cadfamily.com EMa The document is for study 5.8.5 Stripchart Tab.......................................................................221 5.8.6 User Variables Tab.................................................................221 5.9 Set..............................................................................................222 5.9.1 Set Property View .................................................................222 5.9.2 Connections Tab....................................................................223 5.9.3 Parameters Tab.....................................................................224 5.9.4 User Variables Tab.................................................................225 5.10 Spreadsheet..............................................................................225 5.10.1 Spreadsheet Property View...................................................226 5.10.2 Spreadsheet Functions.........................................................227 5.10.3 Spreadsheet Interface..........................................................232 5.10.4 Spreadsheet Tabs................................................................237 5.11 Stream Cutter ...........................................................................244 5.11.1 Stream Cutter Property View ................................................245 5.11.2 Design Tab .........................................................................253 5.11.3 Transitions Tab....................................................................254 5.11.4 Worksheet Tab ....................................................................261 5.12 Transfer Function .....................................................................261 5.12.1 Transfer Function Property View ............................................263 5.12.2 Connections Tab..................................................................264 5.12.3 Parameters Tab ...................................................................264 5.12.4 Stripchart Tab.....................................................................277 5.12.5 User Variables Tab...............................................................277 5.13 Common Options ......................................................................278 5.13.1 ATV Tuning Technique ..........................................................278 5.13.2 Controller Face Plate............................................................2795-3 il:cadserv21@hotmail.com only,if tort to your rights,please inform us,we will delete 5-4 Adjust ww Th5.1 Adjust The Adjust operation varies the value of one stream variable (the independent variable) to meet a required value or specification (the dependent variable) in another stream or operation. In a flowsheet, a certain combination of specifications may be required, which cannot be solved directly. These types of problems must be solved using trial-and-error techniques. To quickly solve flowsheet problems that fall into this category, the Adjust operation can be used to automatically conduct the trial- and-error iterations for you. The Adjust is extremely flexible. It allows you to link stream variables in the flowsheet in ways that are not possible using ordinary “physical” unit operations. It can be used to solve for the desired value of just a single dependent variable, or multiple Adjusts can be installed to solve for the desired values of several variables simultaneously. The Adjust can perform the following functions: • Adjust the independent variable until the dependent variable meets the target value. • Adjust the independent variable until the dependent variable equals the value of the same variable for another object, plus an optional offset. The Adjust is a steady state operation; HYSYS ignores it in dynamic mode. The Independent variable cannot be a calculated value; it must be specified.5-4 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-5 ww Th5.1.1 Adjust Property View There are two ways that you can add an Adjust to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Logicals radio button. 3. From the list of available unit operations, select Adjust. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing the F4. 2. Double-click the Adjust icon. The Adjust property view appears. Figure 5.1 Adjust icon5-5 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-6 Adjust ww Th5.1.2 Connections Tab The first tab of the Adjust property view, as well as several other logicals, is the Connections tab. The tab contains the following pages: • Connections • Notes Connections Page The Connections page comprises of three groups: • Adjusted Variable • Target Variable • Target Value Adjusted/Target Variable Groups The Adjusted and Target Variable groups are very similar in appearance, each containing an Object field, Variable field, and a Select Var button. • The Adjusted Object is the owner of the independent variable which is manipulated in order to meet the specified value of the Target variable. • The Target Object is the owner of the dependent variable whose value you are trying to meet. A Target Object can be a unit operation, stream, or a utility. Figure 5.25-6 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-7 ww Th• The Select Var button enables you to select a variable for the Adjusted and Target objects. Target Value Group Once the target object and variable are defined, there are three choices for how the target is to be satisfied: • If the target variable is to meet a certain numerical value, select the User Supplied radio button (as shown in the figure below), and enter the appropriate value in the Specified Target Value field. • If the target variable is to meet the value (or the value plus an offset) of the same variable in another stream or operation, select the Another Object radio button (as shown in the figure below), and select the stream or operation of interest from the Matching Value Object drop-down list. If applicable, enter an offset in the available field. • If the target variable is to meet the value (or the value plus an offset) of the same variable specified in the spreadsheet, select the SpreadSheetCell Object radio button (as shown in the figure below), and select the cell that you want from the Matching Value Object drop-down Figure 5.3 Figure 5.4 Refer to Section 1.3.9 - Variable Navigator Property View for information.5-7 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-8 Adjust ww Thlist. This allows the SpreadSheetCell to be attached as an adjusted variable, and source to the target variable. You can also specify the offset in the available field. Notes Page The Notes page provides a text editor, where you can record any comments or information regarding the operation or to your simulation case in general. 5.1.3 Parameters Tab Once you have chosen the dependent and independent variables, the convergence criteria must be defined. This is usually done on the Parameters tab. The Parameters tab has two pages: • Parameters • Options Parameters Page The Parameters page allows you to specify the adjust parameters: Figure 5.5 Solving Parameter Description Simultaneous Solution Solves multiple Adjust loops simultaneously. There is only one simultaneous solving method available therefore when this checkbox is selected the Method field is no longer visible. Method Sets the (non-simultaneous) solving method: Secant or Broyden. Tolerance Sets the absolute error. In other words, the maximum difference between the Target Variable and the Target Value. For more information, refer to Section 1.3.5 - Notes Page/Tab.5-8 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-9 ww ThChoosing the Solving Methods Adjust loops can be solved either individually or simultaneously. If the loop is solved individually, you have the choice of either a Secant (slow and sure) or Broyden (fast but not as reliable) search algorithm. The Simultaneous solution method uses modified Levenberg-Marquardt method search algorithm. A single Adjust loop cannot be solved in the Simultaneous mode. In Simultaneous mode, the adjust variable is adjusted after the last operation in the flowsheet has solved. The calculation level has no effect on the Adjust operation in the Simultaneous mode. When the Simultaneous Solution checkbox is selected, the Step Size The initial step size employed until the solution is bracketed. Maximum / Minimum The upper and lower bounds for the independent variable (optional) are set in this field. Maximum Iterations The number of iterations before HYSYS quits calculations, assuming a solution has not been obtained. Sim Adj Manager Opens the Simultaneous Adjust Manager allowing you to monitor and modify all Adjusts that are selected as simultaneous. Optimizer Controlled Passes a variable and a constant to the optimizer. When activated the efficiency of the simultaneous Adjust is increased. This option requires RTO. The Calculation Level for an Adjust (accessed under Main Properties) is 3500, compared to 500 for most streams and operations. This means that the Adjust is solved last among unknown operations. You can set the relative solving order of the Adjusts by modifying the Calculation Level. Solving Parameter Description5-9 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-10 Adjust ww ThMethod field is no longer visible. Simultaneous Adjust Manager The Simultaneous Adjust Manager (SAM) property view allows you to monitor, and modify all Adjusts that are selected as simultaneous. This gives you access to a more efficient method of calculation, and more control over the calculations. The SAM property view is launched by clicking the Sim Adj Manager button on the Parameters tab, or by selecting Simultaneous Adjust Manager command from the Simulation menu. The SAM property view contains the following tabs: • Configuration • Parameters • History Figure 5.6 All adjusts from old cases in Simultaneous mode are automatically added to the SAM. The SAM requires two or more active (in other words, not ignored) adjusts to solve. If you are using only one adjust, you cannot use the SAM.5-10 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-11 ww ThThe SAM property view also contains the following common objects at the bottom of the property view: • The status bar, which displays the status of the SAM calculation. • The Stop and Start buttons, which are used to start and stop the SAM calculations repectively. • The Ignored checkbox, which enables you to toggle on and off the SAM feature and all of the selected Adjusts simultaneously. Configuration Tab The Configuration tab displays information regarding Adjusts that have been selected as simultaneous. You can view the individual Adjusts by double-clicking on the Adjust name. You can also modify the target value or matching value object, value, and offset. This tab also allows you to ignore individual Adjusts. Parameters Tab The Parameters tab allows you to modify the tolerance, step size, max, and min values for each Adjust, as well as, displays the residual, number of iterations the SAM has taken, and the Figure 5.75-11 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-12 Adjust ww Thiteration status. This tab also allows you to specify some of the calculation parameters as described in the table below. History Tab The History tab displays the target value, adjusted value, and residual value for each iteration of the selected Adjust(s). One or more Adjusts can be displayed by clicking on the checkbox beside the Adjust name. The Adjusts are always viewed in order from left to right across the page. For example, if you are viewing Adjust 2 and add Adjust 1 to the property view, Adjust 1 becomes the first set of numbers, and Adjust 2 is shifted to the right. Parameter Description Type of Jacobian Calculation Allows you to select one of three Jacobian calculations: • ResetJac. Jacobian is fully calculated and values reset to initial values after each jacobian calculation step. Most time consuming but most accurate. • Continuous. Values are not recalculated between Jacobian calculation steps. Quickest, but allows for “drift” in the Jacobian therefore not as accurate. • Hybrid. Hybrid of the above two methods. Type of Convergence Allows you to select one of three convergence types: • Specified. SAM is converged when all Adjusts are within the specified tolerances. • Norm. SAM is converged when the norm of the residuals (sums of squares) is less then a user specified value. • Either. SAM is converged with which ever of the above types occurs first. Max Step Fraction The number x step size is the maximum that the solver is allowed to move during a solve step. Perturbation Factor The number x range (Max - Min) or the number x 100 x step size (if no valid range). This is the maximum that the solver is allowed to move during a Jacobian step. Max # of Iterations Maximum number of iterations for the SAM. The History tab only displays the values from a solve step. The values calculated during a Jacobian step can be seen on the Monitor tab of the adjust for the individual results.5-12 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-13 ww ThTolerance For the Adjust to converge, the error in the dependent variable must be less than the Tolerance. It is sometimes a good idea to use a relatively loose (large) tolerance when initially attempting to solve an Adjust loop. Once you determine that everything is working properly, you can reset the tolerance to the final design value. Step Size The step size you enter is used by the search algorithm to establish the maximum step size adjustment applied to the independent variable. This value is used until the solution has been bracketed, at which time a different convergence algorithm is applied. The value which is specified should be large enough to permit the solution area to be reached rapidly, but not so large as to result in an unreasonable overshoot into an infeasible region. A positive step size initially increments the independent variable, while a negative value initially decrements the independent variable. If the Adjust steps away from the solution, the direction of the steps are automatically reversed. (5.1) The tolerance and error values are absolute (with the same units as the dependent variable) rather than relative or percentage-type. A negative initial step size causes the first step to decrement the independent variable. Error Dependent Variable Value Target Value–=5-13 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-14 Adjust ww ThMaximum/Minimum These two optional criteria are the allowable upper and lower bounds for the independent variable. If either bound is encountered, the Adjust stops its search at that point. Maximum Iterations The default maximum number of iterations is 10. Should the Adjust reach this many iterations before converging, the calculations stop, and you are asked if you want to continue with more iterations. You can enter any value for the number of maximum iterations. Options Page The Options page contains two groups of settings: • Secant Solver Options • Generic Solver Options The Secant Solver Options group offers the Relax Internal Bounds option as well as two settings: Bounds Tolerance and Relaxation Percentage. If the secant solver takes a step and is above the target value, it sets the adjusted variable at that time as an internal maximum or minimum. However, HYSYS is not solving problems of the Before installing the Adjust module, it is often good practice to initialize the independent variable, and perform one adjust “manually”. Solve your flowsheet once, and notice the value for the dependent variable, then self-adjust the independent variable and re-solve the flowsheet. This assures you that one variable actually affects the other, and also gives you a feel for the step size you need to specify. The Independent variable must be initialized (have a starting value) in order for the Adjust to work.5-14 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-15 ww Thnature F(x)=y, but rather F(x) = G(x), so that the response surface changes as the adjusted variable changes. This can lead to a situation where we have an internal minimum and internal maximum set to the same value. By using Relax Internal Bounds, you can allow these internal bounds to move out (within the specified minimum and maximum) if the adjusted variable is within the Bounds Tolerance of the local minimum or maximum. The bound can be relaxed by a Relaxation Percentage. The Generic Solver Option group has one option that allows you to specify the solver to Always Stop At Maximum Iterations. 5.1.4 Monitor Tab The Monitor tab contains the following pages: • Tables • Plots5-15 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-16 Adjust ww ThTables Page For each Iteration of the Adjust, the number, adjusted value, target value, and residual appear. If necessary, use the scroll bar to view iterations which are not currently visible. Figure 5.8 You can also use the Solver Trace Window to view the Iteration History. Iteration Number Dependent (Target) Variable Independent (Adjusted) Variable Residual (Error) Refer to Section 1.3 - Object Status & Trace Windows in the HYSYS User Guide for more information.5-16 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-17 ww ThPlots Page The Plots page displays the target and adjusted variables like on the Tables page, except the information is presented in graph form. 5.1.5 User Variables Tab The User Variables tab enables you to create and implement your own user variables for the current operation. Figure 5.9 Refer to Section 1.3.1 - Graph Control Property View for information on customizing plots. For more information, refer to Section 1.3.8 - User Variables Page/ Tab.5-17 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-18 Adjust ww Th5.1.6 Starting the Adjust There are two ways to start the Adjust: • If you have provided values for all the fields on the Parameters tab, the Adjust automatically begins its calculations. • If you have omitted one or both values in the Minimum/ Maximum fields (on the Parameters tab) for the independent variable (which are optional parameters), and you would like the Adjust to start calculating, simply click the Start button. The Start button then disappears, indicating the progress of the calculations. When the error is less than the tolerance, the status bar displays in green the “OK” message. If the Adjust reaches the maximum number of iterations without converging, the “Reached iteration Limit without converging” message appears in red on the status bar. If you click the Start button when all of the required parameters are not defined, the status bar displays in yellow the “Incomplete” message, and calculations cannot begin. Once calculations are underway, you can view the progress of the convergence process on the Iterations tab. With the exception of the minimum and maximum values of the independent (adjusted) variable, all parameters are required before the Adjust begins its calculations. The Start button only appears in the initialization stage of the Adjust operation. It disappears from the property view as soon as it is pressed. Any changes made to the Adjust or other parts the flowsheet automatically triggers the Adjust calculation. To stop or disable the Adjust select the Ignored checkbox.5-18 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-19 ww Th5.1.7 Individual Adjust The Individual Adjust algorithm, either Secant or Broyden, uses a step-wise trial-and-error method, and displays values for the dependent and independent variables on each trial. The step size specified on the Parameters tab is used to increment, or decrement the independent variable for its initial step. The algorithm continues to use steps of this size until the solution is bracketed. At this point, depending on your choice, the algorithm uses either the Secant search (and its own step sizes) or Broyden search to quickly converge to the desired value. If a solution has not been reached in the maximum number of iterations, the routine pauses, and asks you whether another series of trials should be attempted. This is repeated until either a solution is reached, or you abandon the search. The Secant search algorithm generally results in good convergence once the solution has been bracketed. 5.1.8 Multiple Adjust The term Multiple Adjust typically applies to the situation where all of the Adjusts are to be solved simultaneously. In this case, where the results of one Adjust directly affect the other(s), you can use the Simultaneous option to minimize the number of flowsheet iterations. Examples where this feature is very valuable include calculating the flow distribution of pipeline looping networks, or in solving a complex network of UA-constrained heat exchangers. In these examples, you must select the stream parameters which HYSYS is to manipulate to meet the desired specifications. For a pipeline looping problem, the solution may be found by adjusting the flows in the branched streams until the correct pressures are achieved in the pipelines downstream. In any event, it is up to you to select the variables to adjust to solve your flowsheet problem. HYSYS uses the modified Levenberg-Marquardt algorithm to simultaneously vary all of the adjustable parameters defined in the Adjusts until the desired specifications are met. The role of Refer to Chapter C2 - Synthesis Gas Production in the HYSYS Tutorials and Applications guide for an example using Multiple Adjusts.5-19 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-20 Balance ww Thstep size with this method is quite different. With the single Adjust algorithm, step size is a fixed value used to successively adjust the independent variable until the solution has been bracketed. With the simultaneous algorithm, the step size for each variable serves as an upper limit for the adjustment of that variable. In solving multiple UA exchangers, the starting point should not be one that contains a temperature crossover for one of the heat exchangers. If this occurs, a warning message appears informing you that a temperature crossover exists, and a very large UA value is computed for that heat exchanger. This value is insensitive to any initial change in the value of the adjustable variable, and therefore the matrix cannot be solved. Install all Adjusts using the simultaneous option on the Parameters tab, then click the Start button to begin the calculations. 5.2 Balance The Balance operation provides a general-purpose heat and material balance facility. The only information required by the Balance is the names of the streams entering and leaving the operation. For the General Balance, component ratios can also be specified. Since HYSYS permits streams to enter or leave more than one operation, the Balance can be used in parallel with other units for overall material and energy balances. One requirement in implementing the Multiple Adjust feature is that you must start from a feasible solution. The Balance overrides the filtering of streams that HYSYS typically performs. Refer to Section 4.4 - Heat Exchanger for more information.5-20 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-21 ww ThThe Balance Operation solves in both the forward and backward directions. For instance, it backs out the flowrate of an unknown feed, given that there are no degrees of freedom. There are six Balance types which are defined in the table below: 5.2.1 Balance Property View There are two ways that you can add a Balance to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Logicals radio button. 3. From the list of available unit operations, select Balance. Balance Type Definition Mole An overall balance is performed where only the molar flow of each component is conserved. It can be used to provide material balance envelopes in the flowsheet, or to transfer the flow and composition of a process stream into a second stream. Mass An overall balance is performed where only the mass flow is conserved. A common application would be for modeling reactors with no known stoichiometry, but for which analyses of all feeds and products are known. Heat An overall balance is performed where only the heat flow is conserved. An application would be to provide the pure energy difference in a heat balance envelope. Mole and Heat An overall balance is performed where the heat and molar flow are conserved. The most common application for this unit operation would be to perform overall material (molar basis) and energy balance calculations of selected process streams to either check for balances, or force HYSYS to calculate an unknown variable, such as flow. Most of the unit operations in HYSYS perform the equivalent of a Mole and Heat Balance besides their other more specialized calculations. Mass and Heat An overall balance is performed where the overall mass flow and heat flow are conserved. General HYSYS solves a set of n unknowns in the n equations developed from the streams attached to the operation. Component ratios can be specified on a mole, mass or liquid volume basis.5-21 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-22 Balance ww Th4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the Balance icon. The Balance property view appears. 5.2.2 Connections Tab The Connections tab is the same for all of the Balance Types. Figure 5.10 Figure 5.11 Balance icon5-22 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-23 ww ThThe tab contains the following pages: • Connections • Notes Connections Page On the Connections page, you must specify the following information: • Name. The name of the balance operation. • Inlet Streams. Attach the inlet streams to the balance. • Outlet Streams. Enter the outlet streams to the balance operation. You can have an unlimited number of inlet and outlet streams. Use the scroll bar to view streams that are not visible. 5.2.3 Parameters Tab The Parameters tab contains two groups: • Balance Type • Ratio List The Balance Type group contains a series of radio buttons, which allow you to choose the type of Balance you want to use. The radio buttons are: • Mole • Mass Figure 5.12 Refer to Section 1.3.5 - Notes Page/Tab for more information.5-23 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-24 Balance ww Th• Heat • Mole and Heat • Mass and Heat • General Mole Balance This operation performs an overall mole balance on selected streams; no energy balance is made. It can be used to provide material balance envelopes in the flowsheet or to transfer the flow and composition of a process stream into a second stream. • The composition does not need to be specified for all streams. • The direction of flow of the unknown is of no consequence. HYSYS calculates the molar flow of a feed to the operation based on the known products, or vice versa. • This operation does not pass pressure or temperature. Mass Balance This operation performs an overall balance where only the mass flow is conserved. An application is the modeling of reactors with no known stoichiometry, but for which analyses of all feeds and products are available. If you specify the composition of all streams, and the flowrate for all but one of the attached streams, the Mass Balance operation determines the flowrate of the unknown stream. This is a common application in alkylation units, hydrotreaters, and other non-stoichiometric reactors. • The composition must be specified for all streams. • The flowrate must be specified for all but one of the streams. HYSYS determines the flow of that stream by a mass balance. • Energy, moles, and chemical species are not conserved. The Mass Balance operation determines the equivalent masses of the components you have defined for the inlet and outlet streams of the operation. • This operation does not pass pressure or temperature. The Ratio List group applies only to the General balance. This is discussed in the General Balance section.5-24 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-25 ww ThHeat Balance This operation performs an overall heat balance on selected streams. It can be used to provide heat balance envelopes in the flowsheet or to transfer the enthalpy of a process stream into a second energy stream. • The composition and material flowrate must be specified for all material streams. The heat flow is not passed to streams which do not have the composition and material flowrate specified, even if there is only one unknown heat flow. • The direction of flow for the unknown stream is of no consequence. HYSYS calculates the heat flow of a feed to the operation based on the known products, or vice versa. • This operation does not pass the pressure or temperature. • You cannot balance the heat into a Material Stream. Mole and Heat Balance The most common application for this balance is to perform overall material (molar basis), and energy balance calculations of selected process streams to either check for balances or force HYSYS to calculate an unknown variable, such as a flowrate. • The Mole and Heat Balance independently balance energy and material. • The Mole and Heat Balance calculate ONE unknown based on a total energy balance, and ONE unknown based on a total material balance. • The operation is not directionally dependent for its calculations. Information can be determined about either a feed or product stream. • The balance remains a part of your flowsheet and as such defines a constraint; whenever any change is made, the streams attached to the balance always balances with regard to material and energy. As such, this constraint reduces by one the number of variables available for specification. • Since the Mole and Heat Balance work on a molar basis, it should not be used in conjunction with a reactor where chemical species are changing.5-25 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-26 Balance ww ThMass and Heat Balance Similar to the Mass balance mode, this balance mode performs a balance on the overall mass flow. In addition, however, energy is also conserved. • The composition must be specified for all streams. • Flow rate must be specified for all but one of the streams. HYSYS determines the flow of that stream by a mass balance. • Enthalpy must be specified for all but one of the streams. HYSYS determines the enthalpy of that stream by a heat balance. • Moles and chemical species are not conserved. General Balance The General Balance is capable of solving a greater scope of problems. It solves a set of n unknowns in the n equations developed from the streams attached to the operation. This operation, because of the method of solution, is extremely powerful in the types of problems that it can solve. Not only can it solve unknown flows and compositions in the attached streams (either inlet or outlet can have unknowns), but ratios can be established between components in streams. When the operation determines the solution, the prescribed ratio between components are maintained. • The General balance solves material and energy balances independently. An Energy Stream is an acceptable inlet or outlet stream. • The operation solves unknown flows or compositions, and can have ratios specified between components in one of the streams. • Ratios can be specified on a mole, mass or liquid volume basis. Ratios A Ratio, which is unique to the general Balance, is defined between two components in one of the attached streams. Multiple ratios within a stream (for example 1:2 and 1:1.5) can be set with a single Ratio on a mole, mass or liquid volume 5-26 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-27 ww Thbasis. Each individual ratio (1:2, 1:1, and 1:1.5), however uses a degree of freedom. To set a ratio: 1. On the Parameters tab of the Balance operation property view, select the General Balance radio button. The Ratio List group should now be visible. 2. Click the Add Ratio button to access the Ratio property view. 3. In the Ratio property view, specify the following information: • Name. The name of the Ratio. • Stream. The name of the stream. • Ratio Type. Allows you to specify the Ratio Type: Mole, Mass, or Volume. • Component/Ratio. Provides the relative compositions of two or more components. Other components in the stream are calculated accordingly, and it is not necessary nor advantageous to include these in the table. All ratios must be positive; non-integer values are acceptable. Figure 5.13 Figure 5.14 To view a specific ratio, select the ratio in the Ratio List group and click the View Ratio button. To delete a ratio, open the Ratio property view of the component ratio, and then click the Delete button in that Ratio property view.5-27 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-28 Balance ww ThNumber of Unknowns The general Balance determines the maximum number of equations, and hence unknowns, in the following manner (notice that the material and energy balances are solved independently): • One equation performing an overall molar flow balance. • {Number of Components (nc)} equations performing an individual molar balance. • {Number of Streams (ns)} equations, each performing a summation of individual component fractions on a stream by stream basis. This is the maximum number of equations (1 + nc + ns), and hence unknowns, which can be solved for a system. When ratios are specified, they reduce the available number of unknowns. For each ratio, the number of unknowns used is one less than the number of components in the ratio. For example, for a three-component ratio, two unknowns are used. 5.2.4 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. 5.2.5 Stripchart Tab The Stripchart tab allows you to select and create default strip charts containing various variable associated to the operation. 5.2.6 User Variables Tab The User Variables tab enables you to create and implement your own user variables for the current operation. Refer to Section 1.3.10 - Worksheet Tab for more information. Refer to Section 1.3.7 - Stripchart Page/Tab for more information. For more information refer to Section 1.3.8 - User Variables Page/ Tab.5-28 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-29 ww Th5.3 Boolean Operations The Boolean Logic block is a logical operation, which takes in a specified number of boolean inputs and then applies the boolean operation to calculate an output. A typical use of the Boolean Logic is to apply emergency shutdown of an exothermic reactor, such as closing the valves on the fuel and air line to the reactor when the reactor core temperature exceeds its setpoint. It is also used to simulate the ladder diagrams, which are found in most of the electrical applications. The following Boolean Logic blocks are available in HYSYS: • And Gate • Or Gate • Not Gate • Xor Gate • On Delay Gate • Off Delay Gate • Latch Gate • Counter Up Gate • Counter Down Gate • Cause And Effect Matrix To evaluate the Boolean Logic blocks at each time step, open the Integrator property view and go to the Execution tab. In the Calculation Execution Rates group, change the Control and Logical Ops field value to 1. This change ensures that your time sensitive Boolean Logic blocks like On Delay and Off Delay are executed at the required time instead of a one time step delay. This change also slows down the HYSYS calculation rate and is noticeable for large cases. For more information about the Integrator property view, refer to Section 7.7 - Integrator in the HYSYS User Guide.5-29 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-30 Boolean Operations ww Th5.3.1 Boolean Logic Blocks Property View There are two ways that you can add Boolean Logic Blocks to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Logicals radio button. 3. From the list of available unit operations, select the Boolean Logic that you want. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Click on the Boolean Ops icon. The Boolean Palette appears. Figure 5.15 Boolean Ops icon5-30 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-31 ww Th3. Double-click the icon of the Boolean Logic that you want. The selected Boolean Logic property view appears. The property view for all the Boolean Logic blocks in HYSYS contains four tabs (Connections, Monitor, Stripchart, and User Variables), a Delete button, and a Face Plate button. Boolean Logic Icon Boolean Logic Icon Not Gate On Delay Gate And Gate Latch Gate Or Gate Counter Up Gate Xor Gate Counter Down Gate Off Delay Gate Cause And Effect Matrix Figure 5.165-31 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-32 Boolean Operations ww ThLogical Operation Face Plate Property View The Face Plate button enables you to access the Face Plate property view. The Face Plate property view allows you to see the Boolean type and output value at a glance. On the PFD property view, the digital/boolean and boolean/ boolean logical connections have the capability to display the change of logical state by changing the line colour to either green (1) or red (0). The output is set up to have a default initial value of 1 for all the Boolean Logic blocks. Connections Tab The Connections tab is where you connect operations to the Boolean Logic block. Boolean unit operations can make logical connections with Digital Point, as well as, among themselves. The connections can either be made from the Connections tab, or through the PFD. If the Boolean type supports multiple process variable sources, the Process Variable Sources group contains a table with three buttons with the same functions as the buttons in the Output Target group. Figure 5.17 Figure 5.18 Click on the Setup button to open the Boolean Logic property view. This field displays the Boolean Logic type. This field displays the output value. OP = 0 OP = 15-32 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-33 ww ThThe figure below displays the Connections tab of a Boolean Not Gate operation. Adding/Editing Process Variable Source Depending on the Boolean type, you have to click the Select PV button, the Edit PV button or the Add PV button to open the Select Input PV property view. Figure 5.19 Figure 5.20 The Select Input PV property view is similar to the Variable Navigator property view. The type of Boolean Logic block is shown in this display field. Edit OP button allows you to change the selected output connection. Add OP button allows you to add an output connection. Delete OP button allows you to delete the selected output connection. Refer to Section 1.3.9 - Variable Navigator Property View for information on.5-33 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-34 Boolean Operations ww ThAdding/Editing Output Target Click the Edit OP button or Add OP button to open the Select Output PV property view. Use the radio button in the Object Filter group to filter the Object list to the operations you want. Monitor Tab The Monitor tab allows you to monitor the input and output values of the Boolean Logic block. The contents of this tab varies from one Boolean Logic type to another. For example, the Monitor tab of an On Delay Gate boolean also contains a field where you can specify the time delay. Stripchart Tab The Stripchart tab allows you to select and create default strip charts containing various variable associated to the operation. User Variables Tab The User Variables tab enables you to create and implement your own user variables for the current operation. Figure 5.21 Select the operation to receive the output value from the list, then click the OK button. Click the Disconnect button to disconnect the connection in the property view. Click the Cancel button to exit the property view without changing anything. Refer to Section 1.3.7 - Stripchart Page/Tab for more information. For more information refer to Section 1.3.8 - User Variables Page/ Tab.5-34 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-35 ww Th5.3.2 And Gate This unit operation performs a logical AND function on a set of inputs. The output is always low as long as any one of the input is low and it is high when all of the inputs are high. The table below displays the function logic for the And Gate. The Monitor tab of the And Gate displays the following information: • Input. Contains the name and number used to designate the input connection. • Object. Displays the operation name of the input connection. • Initial State. Displays the input value received by the Boolean Logic block. • Output Value. Displays the output value of the Boolean Logic block, based on the Boolean type and the input values from the input connections. Input 1 Input 2 Input 3 Output 1 1 1 1 1 0 0 0 0 1 0 0 0 0 1 0 0 0 0 0 The And Boolean Logic block can have any number of inputs and a single output, which can be fanned out. The input and output values can only be 1 or 0. Figure 5.225-35 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-36 Boolean Operations ww Th5.3.3 Or Gate This unit operation performs a logical OR function on a set of inputs. The output is always high as long as any one of the input is high and it is low when all of the inputs are low. The table below displays the function logic for the Or Gate. The Monitor tab of the Or Gate displays the same information as the And Gate. Input 1 Input 2 Input 3 Output 1 1 1 1 1 0 0 1 0 1 0 1 0 0 1 1 0 0 0 0 The Or Boolean Logic block can have any number of inputs and a single output, which can be fanned out. The input and output values can only be 1 or 0. Figure 5.235-36 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-37 ww Th5.3.4 Not Gate This unit operation perform a logical NOT function on an input. The output is the negative of the input. In other words, when the input is high the output is low and vice versa. The table below displays the function logic for the Not Gate. The Monitor tab of the Not Gate displays the following information: • Input Value. Displays the value received by the Boolean Logic block. • Output Value. Displays the output value of the Boolean Logic block, based on the input value from the input connection. Input Output 1 0 0 1 The input and output values can only be 1 or 0. The output in this unit operation can also be fanned out. Figure 5.245-37 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-38 Boolean Operations ww Th5.3.5 Xor Gate This unit operation performs an exclusive or function on two inputs. The output state is always High (1) whenever anyone of the input is high (1), but it is low (0) when all of the inputs are high (1). The table below displays the function logic for Xor Gate. The Monitor tab of the Xor Gate displays the following information: • Input. Contains the name and number used to designate the input connection. • Object. Displays the operation name of the input connection. • Initial State. Displays the input value received by the Boolean Logic block. • Output Value. Displays the output value of the Boolean Logic block, based on the Boolean type and the input values from the input connections. Input 1 Input 2 Output 1 1 0 1 0 1 0 1 1 0 0 0 The input and output values can only be 1 or 0. This unit operation can only have two input connections. The output in this unit operation can also be fanned out. Figure 5.255-38 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-39 ww Th5.3.6 On Delay Gate This unit operation performs an on time delay function on a single input. The output’s signal is delayed for a specified time delay ( ) only when the input is set to be 1. The following logical expression is used to calculate the output (y) for an input (x) change. The Monitor tab of the On Delay Gate displays the following information: • Delay Time. Allows you to specify the amount of time you want for the time delay function. The default value is 10 minutes. • Input Value. Displays the value received by the Boolean Logic block. • Output Value. Displays the output value of the Boolean Logic block, based on the input value from the input connection. For x = 1, (5.2) The input and output values can only be 1 or 0. The output in this unit operation can also be fanned out. Figure 5.26 θ y t( ) 0 t θ< 1 t θ≥⎩ ⎨ ⎧ = 5-39 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-40 Boolean Operations ww Th5.3.7 Off Delay Gate This unit operation performs an off time delay function on a single input. The output’s signal is delayed for a specified time delay ( ) only when the input is set to be 0. The following logical expression is used to calculate the output (y) for an input (x) change. The Monitor tab of the Off Delay Gate displays the following information: • Delay Time. Allows you to specify the amount of time you want for the time delay function. The default value is 10 minutes. • Input Value. Displays the value received by the Boolean Logic block. • Output Value. Displays the output value of the Boolean Logic block, based on the input value from the input connection. For x = 0, (5.3) The input and output values can only be 1 or 0. The output in this unit operation can also be fanned out. Figure 5.27 θ y t( ) 1 t θ< 0 t θ≥⎩ ⎨ ⎧ = 5-40 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-41 ww Th5.3.8 Latch Gate This unit operation provides a latch functionality. It requires two input signals; one for set and other one for reset. The second input is the prevailing input meaning that it specify the output to be set to high (1), reset to low (0), or left unchanged. The table below displays the function logic for the Latch Gate. The Monitor tab of the Latch Gate displays the following information: • Prevailing Input. The radio buttons come into play when both of the inputs are high(1). It allows you to specify what you want the output value to be. Selecting Set makes the OP value to be high(1), and Reset makes it low(0). • Input. Contains the name and number used to designate the input connection. • Object. Displays the operation name of the input connection. • Initial State. Displays the input value received by the Boolean Logic block. Input 1 Input 2 Output 1 1 override state 1 0 1 0 1 0 0 0 previous state By definition the latch gate allows you to select the OP value when both of its inputs are high. So this state is known in the industry as override state. The input and output values can only be 1 or 0. This unit operation can only have two input connections. The output in this unit operation can also be fanned out.5-41 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-42 Boolean Operations ww Th• Output Value. Displays the output value of the Boolean Logic block, based on the input value from the input connection. 5.3.9 Counter Up Gate This unit operation acts as an up counter. It counts up to a maximum counter value which is specified by the users. It is triggered everytime the input is switched to a desired state. After reaching the maximum counter limit, it sets the output to a predefined value. The counter and output value is reset with the second input by switching it to high (1). The Monitor tab of the Counter Up Gate displays the following information: • Maximum Counter. Allows you to specify the counter limit value. The default value is 10. • Current Counter. Displays the current counter value. • PV Alarm. Allows you to select which PV value triggers the counter to increase a step. You can only choose 0 or 1. • Desired Output Value. Allows you to select what the output value should be when the counter reaches maximum. You can only choose 0 or 1. • Input. Contains the name and number used to designate the input connection. • Object. Displays the operation name of the input connection. Figure 5.28 The input and output values can only be 1 or 0. The output in this unit operation can also be fanned out.5-42 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-43 ww Th• Initial State. Displays the input value received by the Boolean Logic block. • Output Value. This field displays the output value of the Boolean Logic block, based on the input value from the input connection. 5.3.10 Counter Down Gate This unit operation acts as a down counter. It counts down to a maximum counter value which is specified by the users. It is triggered everytime the input 1 is switched to a desired state. After the counter has reached zero, it sets the output to a predefined value. The counter and output value is reset with the second input by switching it to High (1). The Monitor tab of the Counter Down Gate displays the following information: • Maximum Counter. Allows you to specify the counter limit value. The default value is 10. • Current Counter. Displays the current counter value. • PV Alarm. Allows you to select which PV value triggers the counter to decrease a step. You can only choose 0 or 1. • Desired Output Value. Allows you to select what the output value should be when the counter reaches 0. You can only choose 0 or 1. Figure 5.295-43 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-44 Boolean Operations ww Th• Input. Contains the name and number used to designate the input connection. • Object. Displays the operation name of the input connection. • Initial State. Displays the input value received by the Boolean Logic block. • Output Value. Displays the output value of the Boolean Logic block, based on the input value from the input connection. 5.3.11 Cause and Effect Matrix This unit operation replicates a Cause and Effect matrix commonly used in designing and operating the safety system of many processing plants. It looks at process values throughout the process and, based upon safety thresholds, determines if certain equipment and/or valves should be shutdown. The unit operation is similar to a spreadsheet. It takes inputs called Causes, and sends outputs called Effects. The input may be any simulation variable from the users case or a simple switch which is not required to be connected to an object’s variable. Each input generates either a Healthy (1) or Tripped (0) state. The input and output values can only be 1 or 0. The output in this unit operation can also be fanned out. Figure 5.30 Refer to Section 5.10 - Spreadsheet for more information on the spreadsheet.5-44 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-45 ww ThThe output is a boolean (1 or 0) result from processing one of the Cause and Effect Matrix columns. The output may write or export its result to any simulation variable within the users case. The user must specify a variable of discrete type (1 or 0). The output is not required to be connected to an object or variable. The same 1 or 0 result is produced from the matrix column, and then any other object in the simulation may read or use this value. The matrix is processed one column at a time to determine the resultant state of the output associated with that column. The associated input state is reviewed for each element (or row entry) of a particular column having a non-blank user specified matrix element. All of the matrix elements of that column (and their associated input state) are compared based upon their respective and collective meaning to determine the Cause result. The boolean inputs enter through logical gate type operations (and, or, not, and so forth) with each other to determine the resultant boolean value. It is important that you clarify the 1 and 0 convention of the Cause and Effect Matrix for Healthy/Tripped, On/Off, Start/ Stop, and so forth. For both the inputs and outputs, a result of 0 indicates Tripped, whereas a result of 1 indicates Healthy, except where the Invert checkbox is turned on. When the Invert checkbox is turned on, a result of 0 indicates Healthy, whereas a result of 1 indicates Tripped. You can access the Cause and Effect Matrix help property view by clicking on the Cause and Effect Help button on the C&E Matrix tab.5-45 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-46 Boolean Operations ww ThEach matrix element type is described in the following table. Configuring a Cause and Effect Matrix There are no PFD streams or lines that connect to or from the Cause and Effect Matrix operation. Hence you can place it anywhere and on any flowsheet. You can also view all simulation variables across flowsheets, the same as with a Spreadsheet. Matrix Elements Description X TRIP One or more zero input(s) causes a zero output. R RESET One or more 1 inputs causes a 1 output (as long as there are no X, T or C active and ALL P must be 1) There is no requirement to have a reset on a particular output. If you want a reset, this can either be done with one or more R matrix element entries or a local reset switch. In the case of both R and a local reset, then both reset features must be reset for the output to return to normal, and the local reset must be done last. T TIMED TRIP Same as the TRIP but the input must have remained zero for at least the time period. The T matrix element should be followed by an integer representing the number of seconds of time delayed trip. C COINCIDENT TRIP In contrast to all other trips, a zero input for ALL the coincident signals of the same grouping causes a zero output. The C matrix element should be followed by an integer representing the Coincident group number. There should be more than one in each group. P PERMISSIVE All P inputs must be 1 to permit an R to have the desired effect. Also required for a STANDBY 1 effect, a local reset and a local switch ON. I INHIBIT A 1 will inhibit any trip of the output which would normally be caused by an X,T or C. S STANDBY A 1 will cause a 1 (as long as there are no X, T or C active and ALL P must be 1), and a zero will cause a zero output (no INHIBIT applicable). Normally one would not want more than one Standby input designation per output. If you have more than one Standby, ALL Standby inputs must have a 1 for the output to be started (1 result). Otherwise, a zero output result is produced. All Permissive inputs must be 1 for the Standby 1 action to occur. It is recommended that you build a dynamics case first with all the specifications in place before adding and configuring a Cause and Effect Matrix. Refer to Section 5.10 - Spreadsheet for more information on the spreadsheet.5-46 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-47 ww ThTo add a new Cause and Effect Matrix unit operation to the flowsheet, refer to Section 5.3.1 - Boolean Logic Blocks Property View. You can set the global defaults and controls on the Parameters tab as shown in steps below: 1. You can specify the global defaults by clicking on the appropriate checkboxes. 2. You can specify the global control by clicking on the appropriate checkboxes. Figure 5.31 Checkbox Description Input Invert Allows you to set the invert checkbox on for all new inputs. Output Invert Allows you to set the invert checkbox on for all new outputs. Hand Switch Pulse Duration You can specify the pulse duration for any hand Switch inputs that are pulsed. Always Update Output Objects You can select this checkbox, if you want to ensure that the results from the logic calculations are sent every timestep to the output objects. Use Output Resets Select this checkbox if you want the Use Reset checkbox selected for all new outputs. Use Local Switches for Outputs You can select this checkbox, if you want the Use Local Switch checkbox selected for all new outputs. Insert New Above/To Left When you add a new row or column and this checkbox is selected, the row or column will be added above (to the left) of that currently selected row or column. Figure 5.325-47 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-48 Boolean Operations ww ThYou can view all the input and output configuration information on the Parameters tab. Checkbox Description Reset All Outputs If you want to reset all individual outputs, select this checkbox. Bypass All Outputs When you select this checkbox, the Bypass checkbox of each output is turned on. Trace Alarms & Trips If you want to trace the occurrence of input alarms, input trips and output trips, select this checkbox. The Trace Alarms & Trips checkbox affects ALL Cause and Effect matrix instances in your model. Figure 5.335-48 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-49 ww ThConnecting the Inputs 1. On the Connections tab or the C&E Matrix tab, click the Add Input button to add and connect an input. The Simulation Navigator appears. 2. From the Simulation Navigator, select the input variable. Then click OK. By default, the new input is added at the bottom of any existing inputs. From the Parameters tab, select the Insert New Above/To Left checkbox, now the new input is added above the currently selected row. You have to select the bottom blank input row to add to the bottom of the existing inputs. 3. Alternatively, If you want to add switch inputs, click the Add Switch button on the C&E matrix tab. A new input row is added, but no simulation variable needs to be selected. The user can manually change the switch during the operation of the dynamic model. A switch input is useful for a R(eset) matrix element entry. You should make this a Pulse On type switch. Switches can also be useful as an emergency shutdown pushbutton if you want to test your dynamic model response to the trip of a collection of outputs. You can change the state of the switch by clicking on the appropriate radio buttons. Figure 5.345-49 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-50 Boolean Operations ww Th 4. Enter the description, tag, and comment (if any) for the Inputs (Causes). The description appears to the left of each input row, and its associated matrix elements on the C&E Matrix tab. 5. For all inputs with a simulation variable (not a switch), except for the Digital Point’s OP State or an output result from a Cause and Effect matrix, specify the trip threshold. Select the High? checkbox if a value higher than the threshold will result in a tripped input. Otherwise, a low threshold trip is assumed. You can also specify an Alarm threshold, which acts as a pre- alarm prior to the trip actually occurring. Click the Invert checkbox, if you want to invert the meaning of the matrix elements. 6. You can also override the effect of any tripped inputs by clicking on the OR (Override) checkbox in the Inputs (Causes) table on the C&E Matrix tab or the Inputs (Causes) group on the Parameters tab. You can use this as a startup override. If a trip requires a reset, you will have to activate the input(s), which resets it or you may have to reset the local reset. Figure 5.35 In the Inputs (Causes) table, click on a row with the SW checkbox selected. The input can also be a time delayed Trip resulting to zero by entering a non-zero time in the Off Delay field. The inversion (1 to 0 or 0 to 1) occurs at the completion of the normal input processing just before the input result is passed on for matrix processing. Hence the input status, trace messages, and so forth, occur as normal irregardless of inversion. For more information on viewing the specifications for the inputs and outputs, refer to the section on Viewing the Inputs and Outputs Specifications.5-50 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-51 ww ThConnecting the Outputs 1. In the Outputs (Effects) group, click the Add Output button to create a new Cause and Effect Matrix column. Specify the simulation variable that you want the resultant 1 or 0 exported to. By default, the new output is added to the right (end) of any existing outputs. From the Parameters tab, select the Insert New Above/To Left checkbox, and now the new output is added to the left of the currently selected column. You can select the last blank output column to add to the right of the existing outputs. 2. If you want to add a new column without connecting an object’s variable, click the Add Effect button in the Outputs (Effects) group. 3. Select the Reset? checkbox if you want to specify the output has its own local reset switch. This could perhaps represent a solenoid on a shutdown valve in the field. Once the Reset? checkbox is selected, then the Reset checkbox becomes active and relevant. You can add a new column without connecting a simulation variable, if you want to just display a trip. You can also access the outputs result using the input in other logical operations including other Cause and Effect Matrices or using a Spreadsheet Import. Use the Simulation Navigator from that unit operation to select the Cause and Effect Matrix Output Result. It is not recommended to configure an output without a reset. This can be a matrix element R(eset) or a local reset.5-51 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-52 Boolean Operations ww Th4. You can also specify the presence of a local or field switch for the controlled equipment that the output is associated with. To specify the presence, select the SW (Switch) checkbox. Click on the appropriate radio button to set the local switch state. 5. You can click the Invert checkbox in the Outputs (Effects) group if the object being controlled expects a 1 to shutdown rather than a zero. This output inversion is done at the completion of the output processing, therefore the Outputs (Effects) group status bar and property view status window will show a Tripped status when sending a 1. If the trace option is turned on, a Tripped message will be traced, but a final value of 1 will be sent out. 6. Once you have your Cause and Effect Matrix configured, you may want to use the Bypass checkbox of some or all outputs. This then makes the resultant value in the Outputs (Effects) group at the bottom of the C&E Matrix tab turn blue. This value should initialize to 1 and will remain at this until the bypass is released and matrix output processing proceeds. You can bumplessly prevent initialization trips in this manner. Figure 5.36 This switch has as its permissive any inputs with a P matrix element. Also, the switch is interlocked with any inputs affecting a trip of this output. An output must be reset before the local switch state can be changed from off. When a certain input trips, causing a resulting trip in an output, there is also likely to be a cascading set of trips including other inputs which may appear to cause a trip of the original output. To detect what was the first input to cause the output's trip, you will see the relevant first out matrix element which caused the trip turn red. This colour only returns to the default of blue when the output trip has cleared and been reset.5-52 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-53 ww ThChanging the order of the inputs or outputs If the inputs or outputs are not in the order that you want, you can re-sort either the rows or columns of the Cause and Effect Matrix: 1. From the Inputs (Causes) or Outputs (Effects) tables of the C&E Matrix tab, select the row or column you want to move. 2. In the Inputs (Causes) or Outputs (Effects) groups, click on the row or column number displayed in the # field. 3. Type the new number that you want the row or column to be located at. If you type a number that is smaller than the number of the row (or column) you are moving, all rows (or columns) below the new number will be moved down (to the right) hence filling in the empty row (or column). Alternatively, if the new number is greater than the number of the row (or column) you are moving, the rows (or columns) will be moved up (to the left). The row or column number is displayed in blue indicating that the user can change the value.5-53 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-54 Boolean Operations ww ThViewing the Inputs and Outputs Specifications You can view all the specifications for the inputs and outputs on the C&E Matrix tab. Figure 5.37 If you want to view the specifications for the Output: 1. On the C&E Matrix tab, select the column of the Effect data in the Outputs table. 2. The information for that output is shown in the Outputs group at the bottom of the tab. When you click on the matrix element, the specifications for the selected row and column are shown in the Inputs and Outputs groups at the bottom of the tab. If you want to view the specifications for the Input: 1. On the C&E Matrix tab, select the row of the Cause data in the Inputs table. 2. The information for that input is shown in the Inputs group at the bottom of the tab. Inputs (Causes) group Outputs (Effects) group You can drag and drop input or output object/variables to the object or variable columns of the selected row or column in the Inputs (Causes) or Outputs (Effects) groups. Select the variable from some other unit operation, and then use the right mouse button to drag the selection to the desired location. When you drag the variable the pointer changes to this cursor . This functionality is similar to dragging the variable in the Spreadsheet, refer to Section 5.10 - Spreadsheet.5-54 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-55 ww ThThe C&E Matrix tab also shows the state of each input and output. Viewing the Status Messages While integrating, the status window and the Cause and Effect Matrix's status bar may update to show the following three states: 1. one or more outputs have tripped 2. one or more inputs are in alarm 3. one or more outputs require reset (either via an input with an R matrix element or via a local output reset). The status of the inputs and outputs is shown in the table below: State Description Healthy (1 result) Tripped (0 result) For an input this means alarm. For an output this indicates some other state. Refer to the Output status at the bottom of the property view for an indication of the exact status. For both inputs and outputs, this indicates that attention is most likely required. State Inputs Outputs Healthy 1 1 Alarm 2 Tripped 0 0 Reset 2 LocalReset 3 ManualOff 4 AutoOff 55-55 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-56 Boolean Operations ww ThViewing Trace Messages You can also add a time stamp to the trace messages. 1. From the Tools menu, select Preferences. The Session Preferences property view appears. 2. On the Simulation tab, click on the Errors page. 3. Click on the Prefix Integrator Time to Error ad Trace Messages if Dynamics is Running checkbox to add the time stamp to the trace messages, and close the Session Preferences property view. The Cause and Effect Matrix tracing is turned on by selecting the Trace & Alarms checkbox on the Global group of the Parameters tab. Figure 5.385-56 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-57 ww Th5.4 Control Ops HYSYS has four Control operations: • Split Range Controller • Ratio Controller • PID Controller • MPC Controller • DMCplus Controller 5.4.1 Adding Control Operations There are two ways that you can add Control Operations to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Logicals radio button. 3. From the list of available unit operations, select the Control operation you want. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4.5-57 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-58 Control Ops ww Th2. Click on the Control Ops icon. The Controller Palette appears. 3. Double-click the icon of the Control operation that you want. The selected Control operations property view appears. Figure 5.39 Control Operation Icon Control Operation Icon Split Range Controller MPC Controller Ratio Controller DMCplus Controller PID Controller Figure 5.40 Control Ops icon5-58 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-59 ww ThAll Control operations contain the following buttons at the bottom of the property view: • Delete. You can remove the Control ops by clicking this button. • Face Plate. You can access the Face Plate property view by clicking this button. • Control Valve. You can access the Control Valve property view by clicking this button. or • Control OP Port. You can access the Control OP Port property view by clicking this button. 5.4.2 Split Range Controller In the Split Range Controller, several manipulated variables are used to control a single process variable. Here both manipulated variables are driven by the output of a single controller. However, the range of operation for the manipulated variables can be independent of each other. Typical examples include the control of the pressure in a chemical reactor by manipulating the inflow and outflow from the reactor. Another classic example is the temperature control of a vessel by manipulating both the cooling water flow and steam flow to the vessel. When there is more than one controller in the strategy, for example, one single process variable with two controllers and two manipulated variables, the control is referred to as a multiple controller strategy. In the present implementation in HYSYS there are two outputs that you have to choose. The outputs can be configured as having negative or positive gains with ranges that are independent of each other. In other words, there can be an overlap of the ranges. For more information refer to Section 5.13.2 - Controller Face Plate. For more information refer to Section 5.4.7 - Control Valve. For more information refer to Section 5.4.8 - Control OP Port.5-59 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-60 Control Ops ww ThThe figure below shows the Split Range Controller property view. The Split Range Controller property view contains the following tabs: • Connections • Parameters • Split Range Setup • Stripchart • User Variables Figure 5.415-60 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-61 ww ThConnections Tab On the Connections tab, you can select the process variable source and the output target objects. Figure 5.42 Object Description Name field Allows you to change the name of the operation. Process Variable Source group • Select PV button enables you to access the Select Input PV property view and select the source object of the Process Variable. • Object field displays the Process Variable object (stream or operation) that owns the variable you want to compare. • Variable field displays the variable of the selected object. Output Target Object group • Select OP button enables you to access the Select OP Object property view and select the source object of the Output Target. • Object field displays the object (stream or operation) that is controlled by the operation. • Variable field displays the variable of the selected object. Remote Setpoint group • Select RSP button enables you to access the Select Remote Setpoint property view and select the source object of the Remote Setpoint. • Remote Setpoint field displays the selected master controller. Click the up and down arrows to access the first and second variables. If you are using set point from a remote source, select the remote Setpoint Source associated with the Master controller. Refer to Section 1.3.9 - Variable Navigator Property View for information Select Input PV and Select OP Object property view.5-61 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-62 Control Ops ww ThParameters Tab The Parameters tab contains the following pages: • Operation • Configuration • Advanced • Autotuning • IMC Design • Scheduling • Alarms • Signal Processing • Initialization Operation Page On the Operation page, you can manipulate how the operation reacts to the process variable inputs. Figure 5.435-62 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-63 ww ThObject Description Action You can select one of the two types of action available for the operation to take when the process variable value deviates from the setpoint value: • Direct. When the PV rises above the SP, the OP increases. When the PV falls below the SP, the OP decreases. • Reverse. When the PV rises above the SP, the OP decreases. When the PV falls below the SP, the OP increases. Controller Mode You can select from three types of controller mode: • Off. The operation does not manipulate the control valve, although the appropriate information is still tracked. • Manual. Manipulate the operation output manually. • Automatic. The operation reacts to fluctuations in the Process Variable and manipulates the Output according to the logic defined by the tuning parameters. Execution You can select from two types of execution. • Internal. Confines the signals generated to stay within HYSYS. • External. Sends the signals to a DCS, if a DCS is connected to HYSYS. Sp Allows you to specify the setpoint value. Pv Displays the process variable value. Op Displays the output value. Split Range Output Displays the current OP value in percent for each output. Kc (Gain) Allows you to specify the proportional gain of the operation. Ti (Reset) Allows you to specify the integral (reset) time of the operation. Td (Derivative) Allows you to specify the derivative (rate) time of the operation. Refer to Tuning Parameters Group section for more information on Kc, Ti, and Td.5-63 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-64 Control Ops ww ThTuning Parameters Group The Tuning Parameters group allows you to define the constants associated with the PID control equation. The characteristic equation for a PID Controller is given below: where: OP(t) = controller output at time t OPss = steady state controller output (at zero error) E(t) = error at time t Kc = proportional gain of the controller Ti = integral (reset) time of the controller Td = derivative (rate) time of the controller The error at any time is the difference between the Setpoint and the Process Variable: Depending on which of the three tuning parameters you have specified, the Controller responds accordingly to the error. A Proportional-only controller is modeled by providing only a value for Kp, while a PI (Proportional-Integral) Controller requires values for Kp and Ti. Finally, the PID (Proportional-Integral- Derivative) Controller requires values for all three of Kp, Ti, and Td. (5.4) (5.5) OP t( ) OPss KcE t( ) Kc Ti ----- E t( )dt KcTd+ E t( )d dt ------------∫+ += E t( ) SP t( ) PV t( )–=5-64 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-65 ww ThConfiguration Page The Configuration page allows you to specify the process variable, setpoint, and output ranges. PV: Min and Max Group For the operation to become operational, you must: 1. Define the minimum and maximum values for the PV (the operation cannot switch from Off mode unless PVmin and PVmax are defined). 2. Once you provide these values (as well as the Control Valve span), you can select the Automatic mode and give a value for the Setpoint. Figure 5.44 HYSYS uses the current value of the PV as the set point by default, but you can change this value at any time. Without a PV span, the Controller cannot function.5-65 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-66 Control Ops ww ThHYSYS converts the PV range into a 0-100% range, which is then used in the solution algorithm. The following equation is used to translate a PV value into a percentage of the range: SP Low and High Limits Group In this group, you can specify the higher and lower limits for the setpoints to reflect your needs and safety requirements. The setpoint limits enforce an acceptable range of values that could be entered via the interface or from a remote source. By default the PVs min. and max values are used as the SPs low and high limits, respectively. Op Low and High Limits Group In this group, you can specify the higher and lower limits for all the outputs. The output limits ensure that a predetermined minimum, or maximum output value is never exceeded. By default 0% and 100% is selected as a low and a high of limit, respectively for all the outputs. (5.6) When the Enable Op Limits in Manual Mode checkbox is selected, you can enable the set point and output limits when in manual mode. PV %( ) PV PVmin– PVmax PVmin– -------------------------------------⎝ ⎠ ⎛ ⎞ 100=5-66 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-67 ww ThAdvanced Page The Advanced page contains the following four groups described in the table below: The setpoint signal is specified in the Selected Sp Signal # field by clicking the up or down arrow button , or by typing the appropriate number in the field. Depending upon the signal selected, the page displays the respective setpoint settings. Figure 5.45 Group Description Setpoint Ramping Allows you to specify the ramp target and duration. Setpoint Mode Contains the options for setpoint mode and tracking, as well as, the option for remote setpoint. Setpoint Options Contains the option for setpoint tracking only in manual mode. Algorithm Selection Contains the PID controller algorithms for output calculation.5-67 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-68 Control Ops ww ThSetpoint Ramping Group The setpoint ramping function has been modified in the present MPC controllers. Now it is continuous, in other words, when set to on by clicking the Enable button, the setpoint changes over the specified period of time in a linear manner. The Setpoint Ramping group contains the following two fields: • Target SP. Contains the Setpoint you want the Controller to have at the end of the ramping interval. When the ramping is turn off, the Target SP field display the same value as SP field on the Configuration page. • Ramping. Contains the time interval you want to complete setpoint change in. Besides these two fields there are also two buttons available in this group: • Enable. Activates the ramping process. • Disable. Stops the ramping process. While the controller is in ramping mode, you can change the setpoint as follows: • Enter a new setpoint in the Target SP field • Enter a new setpoint in the SP field, on the Operation page. Figure 5.46 Setpoint ramping is only available in Auto mode. Ramping Duration = RTSP SP(t) t t+RT Time Target SP Controller Ramping5-68 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-69 ww ThDuring the setpoint ramping the Target SP field shows the final value of the setpoint whereas the SP field, on the Operation page, shows the current setpoint seen internally by the control algorithm. Setpoint Mode Group You have now the ability to switch the setpoint from local to remote using the Setpoint mode radio buttons. Essentially, there are two internal setpoints in the controller, the first is the local setpoint where the you can manually specify the setpoint via the property view (interface), and the other is the remote setpoint which comes from another object such as a spreadsheet or another controller cascading down a setpoint, in other words, a master in the classical cascade control scheme. The Sp Local option allows you to disable the tracking for the local setpoint when the controller is placed in manual mode. You can also have the local setpoint track the remote setpoint by selecting the Track Remote radio button. The Remote Sp option allows you to select either the Use% radio button (for restricting the setpoint changes to be in percentage) or Use Pv units radio button (for setpoint changes to be in Pv units). • If the Remote Sp is set to Use%, then the controller reads in a value in percentage from a remote source, and using the Pv range calculates the new setpoint. • If the Remote Sp is set to Use Pv units, then the controller reads in a value from a remote source, and sets a new setpoint. The remote source’s setpoint must have the same units as the controller Pv. SetPoint Options Group If you select the Track PV radio button then there is automatic setpoint tracking in manual mode, that sets the value of the During ramping, if a second setpoint change has been activated, then Ramping Duration time would be restarted for the new setpoint.5-69 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-70 Control Ops ww Thsetpoint equal to the value of the Pv prior to the controller being placed in the manual mode. This means that upon switching from manual to automatic mode the values of the setpoint and Pv were equal and, therefore, there was an automatic bumpless transfer. Also you have the option not to track the Pv, by selecting the No Tracking radio button, when the controller is placed in manual mode. However, when the controller is switched into the automatic mode from manual, there is an internal resetting of the controller errors to ensure that there is an instantaneous bumpless transfer prior to the controller recognizing a setpoint that is different from the Pv. Algorithm Selection Group In the Algorithm Selection group you can select one of the three available controller update algorithms: • PID Velocity Form • PID Positional Form (ARW = Anti-Reset Windup) • PID Positional Form (noARW) Velocity or Differential Form In the velocity or differential form, the controller equation is given as: where: u(t) = controller output and t is the enumerated sampling instance in time u(t-1) = value of the output one sampling period ago The velocity or differential form of the controller should be applied when there is an integral term. When there is no integral term a positional form of the controller should be used. (5.7)u t( ) u t 1–( ) Kc e t( ) e t( )– 1 Ti ----e kh( ) Td e t( ) 2e t 1–( )– e t 2–( )+( ) h ------------------------------------------------------------------+ ++=5-70 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-71 ww ThKc, Ti, and Td = controller parameters h = sampling period Positional Form In the positional form of the algorithm, the controller output is given by: Here it is important to handle properly the summation term associated with the integral part of the control algorithm. Specifically, the integral term could grow to a very large value in instances where the output device is saturated, and the PV is still not able to get to the setpoint. For situations like the one above, it is important to reset the value of the summation to ensure that the output is equal to the limit (upper or lower) of the controller output. As such, when the setpoint is changed to a region where the controller can effectively control, the controller responds immediately without having to decrease a summation term that has grown way beyond the upper or lower limit of the output. This is referred to as an automatic resetting of the control integral term commonly called anti-reset windup. In HYSYS both algorithms are implemented as presented above with one key exception, there is no derivative kick. This means that the derivative part of the control algorithm operates on the process variable as opposed to the error term. As such the control equation given in Equation (5.7) is implemented as follows: (5.8) (5.9) u t( ) Kc e t( ) e t( )– 1 Ti ---- e kh( ) k 0= n ∑ Td e t( ) e t 1–( )–( ) h --------------------------------------+ += u t( ) u t 1–( ) Kc e t( ) e t( )– 1 Ti ----e kh( ) Td pv– 2pv t 1–( ) pv t 2–( )–+( ) h --------------------------------------------------------------------------+ ++=5-71 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-72 Control Ops ww ThAutotuning Page You can set the autotuning parameters on the Autotuning page. This page consists two groups: • Autotuner Parameters. Contains the parameters required by the Autotuner to calculate the controller parameters. • Autotuner Results. Displays the resulting controller parameters. You have the option to accept the results as the current tuning parameters. Autotuner Parameters Group In this group, you can specify the controller type by selecting the PID radio button or the PI radio button for the Design Type. Figure 5.47 In the present version of the software there are default values specified for the PID tuning. Before starting the autotuner, you must ensure that the controller is in the manual or automatic mode, and the process is relatively steady. If you move the cursor over the tuning parameters field, the Status Bar displays the parameters range. For more information about autotuning parameters, refer to the Autotuner Page in Section 5.4.4 - PID Controller.5-72 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-73 ww ThIn the present autotuner implementation there are five parameters that you must specify which are as follows: Autotuner Results Group This group displays the results of the autotuner calculation, and allows you to accept the results as the current controller setting. The Start Autotuner button activates the tuning calculation, and the Stop Autotuning button aborts the calculations. After running the autotuner, you have the option to accepts the results either automatically or manually. Selecting the Automatically Accept checkbox sets the resulting controller parameters as the current value instantly. If the Automatically Accept checkbox is inactive, you can specify the calculated controller parameters to be the current setting by clicking the Accept button. IMC Design Page The IMC Design page allows you to use the internal model control (IMC) calculator to calculate the operation parameters based on a specified model of the process one is attempting to control. Parameter Range Ratio (Ti/Td) (Alpha) Gain ratio (Beta) Phase angle (Phi) Relay hysteresis (h) Relay amplitude (d) 3.0 α 6.0≤ ≤ 0.10 β 1.0≤ ≤ 30° φ 65°≤ ≤ 0.01% h 5.0%≤ ≤ 0.5% d 10.0%≤ ≤5-73 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-74 Control Ops ww Th The IMC method is quite common in most of the process industries and has a very solid theoretical basis. In general, the performance obtained using this design methodology is superior to most of the existing techniques for tuning PIDs. As such, when there is a process model available (first order plus delay) this approach should be used to determine the controller parameters. You must specify a design time constant, which is usually chosen as three times that of the measured process time constant. The IMC Design page has the following two groups: As soon as you enter the parameters in the Process Model group, the operation parameters are calculated and displayed in the IMC PID Tuning group. You can accept them as the current tuning parameters by clicking the Update Tuning button. Figure 5.48 Group Description Process Model Contains the parameters for the process model, which are required by the IMC calculator. • Process Gain • Process Time Constraint • Process Delay • Design To IMC PID Tuning Displays the operation parameters.5-74 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-75 ww ThScheduling Page The Scheduling page gives you the ability to do parameter scheduling. This feature is quite useful for nonlinear processes where the process model changes significantly over the region of operation. The parameter scheduling is activated through the Parameter Schedule checkbox. You can use three different sets of PID parameters, if you so desires for three different regions of operation. The following regions of operation can be specified from the Selected Range drop-down list. • Low Range • Middle Range • High Range These regions of operations can be based either on the setpoint, or PV of the controller. The ranges can also be specified, the default values are 0-33%, 33%-66%, and 66%-100% of the selected scheduling signal. You need to specify the middle range limit by defining the Upper and Lower Range Limits. Figure 5.495-75 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-76 Control Ops ww ThAlarms Page The Alarms page allows you to set alarm limits on all exogenous inputs to and outputs from the controller. The Alarms page contains two groups: • Alarm Levels • Alarms Alarm Levels Group The Alarm Level group allows you to set, and configure the alarm points for a selected signal type. There are four alarm points that could be configured: • LowLow • Low • High • HighHigh The values of 0 and 100 cannot be specified for both the Lower and the Upper Range Limits. Figure 5.505-76 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-77 ww ThThe alarm points should be specified in the descending order from HighHigh to LowLow points. You cannot specify the value of the Low and LowLow alarm points to be higher than the signal value. Similarly, the High and HighHigh alarm points cannot be specified to a value lower than the signal value. Also, no two alarm points can be specified to a similar value. In addition, you can specify a deadband for a given set of alarms. This can be helpful in situations where the signal is “noisy” to avoid constant triggering of the alarm. If a deadband is specified, you have to specify the alarm points so that their difference is greater than the deadband. At present the range for the allowable deadband is as follows: of the signal range. Alarms Group The Alarms group displays the recently violated alarm for the following signals: The above limits are set internally, and are not available for adjustment by the user. Signal Description PV Process Variable OP Output SP Setpoint 0.0% deadband 1.5%≤ ≤5-77 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-78 Control Ops ww ThSignal Processing Page The Signal Processing page allows you to add filters to any signal associated with the operation, as well as test the robustness of any tuning on the controller. This page consists of two groups: • Signal Filters • Noise Parameters Both of these groups allow you to filter, and test the robustness of the following tuning parameters: • Pv • Op • Sp • Dv • Rs To apply the filter select the checkbox corresponding to the signal you want to filter. Once active, you can specify the filter time. As you increase the filter time you are filtering out frequency information from the signal. For example, the signal is noisy, there is a smoothing effect noticed on the plot of the PV. Notice that it is possible to add a filter that makes the controller unstable. In such cases the Figure 5.515-78 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-79 ww Thcontroller needs to be returned. Adding a filter has the same effect as changing the process, which the controller is trying to control. Activating a Noise Parameter is done the same way as adding a filter. However, instead of specifying a filter time you are specifying a variance. Notice that if a high variance on the PV signal is chosen the controller may become unstable. As you increase the noise level for a given signal you observe a some what random variation of the signal. Initialization Page The Initialization page allows you to initialize an appropriate OP value to start the controller smoothly. To back initialize the controller, click on the Back Initialization button and HYSYS will initialize the controller output based on the current position of the executor (for example, a valve or another controller). The current back initialization OP value is displayed in the OP value field. Since the split controller has two outputs (two OP values), you can click on the Output1 or Output2 radio button to chose which OP value you want to use to back initialize the controller. Figure 5.525-79 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-80 Control Ops ww ThSplit Range Setup Tab The Split Range Setup tab allows you to specify the split ranges for the controller. The Split Range Setup tab consists of three groups: Split Range Setup, PID Values, and Split Range Outputs. Stripchart Tab The Stripchart tab allows you to select and create default strip charts containing various variable associated to the operation. User Variables Tab The User Variables tab enables you to create and implement your own user variables for the current operation. Figure 5.53 Refer to Section 1.3.7 - Stripchart Page/Tab for more information. For more information refer to Section 1.3.8 - User Variables Page/ Tab.5-80 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-81 ww Th5.4.3 Ratio Controller In the Ratio Controller the objective is to keep the ratio of two variables, the load and the manipulated, constant. The Ratio Controller is a special type of feedforward control, and can be implemented in two ways: • Method 1. The actual ratio of the two variables is calculated using a divider, and is sent on to the ratio controller in which the setpoint is the required ratio. • Method 2. The value of the load variable is measured and sent to a ratio station, which then calculates the setpoint of the manipulated (second) variable. The inclusion of a divider in approach (method 1) renders the methodology less desirable since it results in a loop in which the process gain varies in a nonlinear manner as a result of the included divider. As such, method (2) is the preferred way of doing the ratio implementation, and is the approached followed in this implementation for HYSYS. Figure 5.545-81 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-82 Control Ops ww ThThe Ratio Controller property view contains the following tabs: • Connections • Parameters • Stripchart • User Variables Connections Tab On the Connections tab, you can select the process variable source, and the output target object. You can also select a remote setpoint value. Figure 5.55 Object Description Name Allows you to change the name of the operation. Process Variable Source: Object Contains the Process Variable Object (stream or operation) that owns the variable you want to compare. Process Variable Source: Variable Contains the Process Variable you want to compare. Output Target Object The stream or valve, which is controlled by the operation. Select PV/OP These two buttons open the Variable Navigator which selects the Process Variable and the Output Target Object respectively. Remote Setpoint Source If you are using set point from a remote source, select the remote Setpoint Source associated with the Master controller Click the up and down arrows to access the first and second variables. Refer to Section 1.3.9 - Variable Navigator Property View for information.5-82 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-83 ww ThParameters Tab The Parameters tab contains the following pages: • Operation • Configuration • Advanced • Autotuning • IMC Design • Scheduling • Alarms • Signal Processing • Initialization Operation Page On the Operation page, you can manipulate how the operation reacts to the process variable inputs. Figure 5.565-83 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-84 Control Ops ww ThObject Description Action You can select one of the two types of action available for the operation to take when the process variable value deviates from the setpoint value: • Direct. When the PV rises above the SP, the OP increases. When the PV falls below the SP, the OP decreases. • Reverse. When the PV rises above the SP, the OP decreases. When the PV falls below the SP, the OP increases. Controller Mode You can select from three types of controller mode: • Off. The operation does not manipulate the control valve, although the appropriate information is still tracked. • Manual. Manipulate the operation output manually. • Automatic. The operation reacts to fluctuations in the Process Variable and manipulates the Output according to the logic defined by the tuning parameters. Execution You can select from two types of execution. • Internal. Confines the signals generated to stay within HYSYS. • External. Sends the signals to a DCS, if a DCS is connected to HYSYS. Enable Ratio Control This checkbox has to be selected, if you want to set the ratio value for the operation. If this checkbox is inactive, HYSYS calculates the ratio value between the two selected process variables. Ref. Pv The value in this field is used to calculate the setpoint along with the ratio. Ratio Displays the set or calculated ratio value between the selected the two process variables. Sp Allows you to specify the setpoint value. Pv Displays the process variable value. Op Displays the output value. Gain Allows you to specify the proportional gain of the operation. Reset Allows you to specify the integral (reset) time of the operation. Derivative Allows you to specify the derivative (rate) time of the operation. Refer to the Tuning Parameters Group section for more information on Gain, Reset, and Derivative.5-84 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-85 ww ThTuning Parameters Group The Tuning Parameters group allows you to define the constants associated with the PID control equation. The characteristic equation for a PID Controller is given below: where: OP(t) = controller output at time t OPss = steady state controller output (at zero error) E(t) = error at time t Kc = proportional gain of the controller Ti = integral (reset) time of the controller Td = derivative (rate) time of the controller The error at any time is the difference between the Setpoint and the Process Variable: Depending on which of the three tuning parameters you have specified, the Controller responds accordingly to the error. A Proportional-only controller is modeled by providing only a value for Kp, while a PI (Proportional-Integral) Controller requires values for Kp and Ti. Finally, the PID (Proportional-Integral- Derivative) Controller requires values for all three of Kp, Ti, and Td. (5.10) (5.11) OP t( ) OPss KcE t( ) Kc Ti ----- E t( )dt KcTd+ E t( )d dt ------------∫+ += E t( ) SP t( ) PV t( )–=5-85 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-86 Control Ops ww ThConfiguration Page The Configuration page allows you to specify the process variable, setpoint, and output ranges. PV: Min and Max Group For the operation to become operational, you must: 1. Define the minimum and maximum values for the PV (the operation cannot switch from Off mode unless PVmin and PVmax are defined). 2. Once you provide these values (as well as the Control Valve span), you can select the Automatic mode and give a value for the Setpoint. HYSYS converts the PV range into a 0-100% range, which is then used in the solution algorithm. Figure 5.57 HYSYS uses the current value of the PV as the set point by default, but you can change this value at any time. Without a PV span, the Controller cannot function.5-86 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-87 ww ThThe following equation is used to translate a PV value into a percentage of the range: SP Low and High Limits Group In this group, you can specify the higher and lower limits for the Setpoints to reflect your needs and safety requirements. The Setpoint limits enforce an acceptable range of values that could be entered via the interface or from a remote source. By default the PVs min. and max values are used as the SPs low and high limits, respectively. Op Low and High Limits Group In this group, you can specify the higher and lower limits for all the outputs. The output limits ensure that a predetermined minimum or maximum output value is never exceeded. By default 0% and 100% is selected as a low and a high of limit, respectively for all the outputs. When the Enable Op Limits in Manual Mode checkbox is selected, you can enable the set point and output limits when in manual mode. (5.12)PV %( ) PV PVmin– PVmax PVmin– -------------------------------------⎝ ⎠ ⎛ ⎞ 100=5-87 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-88 Control Ops ww ThAdvance Page The Advanced page contains the following four groups: The setpoint signal is specified in the Selected Sp Signal # field by clicking the up or down arrow button , or typing the appropriate number in the field. Depending upon the signal selected, the Advance page displays the respective setpoint settings. Setpoint Ramping Group The setpoint ramping function has been modified in the present MPC controllers. Now it is continuous, in other words, when set to on by clicking the Enable button, the setpoint changes over Figure 5.58 Group Description Setpoint Ramping Allows you to specify the ramp target and duration. Setpoint Mode Contains the options for setpoint mode and tracking as well as the option for remote setpoint. Setpoint Options Contains the option for setpoint tracking only in manual mode. Algorithm Selection Contains the PID controller algorithms for output calculation.5-88 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-89 ww Ththe specified period of time in a linear manner. The Setpoint Ramping group contains the following two fields: Besides these two fields there are also two buttons available in this group: • Enable. Activates the ramping process. • Disable. Stops the ramping process. While the controller is in ramping mode, you can change the setpoint as follows: • Enter a new setpoint in the Target SP field. • Enter a new setpoint in the SP field, on the Operation page. During the setpoint ramping the Target SP field shows the final value of the setpoint whereas the SP field, on the Operation page, shows the current setpoint seen internally by the control algorithm. Field Input Required Target SP Contains the Setpoint you want the Controller to have at the end of the ramping interval. When the ramping is turn off, the Target SP field display the same value as SP field on the Configuration page. Ramping Duration Contains the time interval you want to complete setpoint change in. Setpoint ramping is only available in Auto mode. Figure 5.59 Ramping Duration = RTSP SP(t) t t+RT Time Target SP Controller Ramping5-89 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-90 Control Ops ww ThSetpoint Mode Group You have now the ability to switch the setpoint from local to remote using the Setpoint mode radio buttons. Essentially, there are two internal setpoints in the controller, the first is the local setpoint where you can manually specify the setpoint via the property view (interface), and the other is the remote setpoint which comes from another object such as a spreadsheet or another controller cascading down a setpoint, in other words, a master in the classical cascade control scheme. The Sp Local option allows you to disable the tracking for the local setpoint when the controller is placed in manual mode. You can also have the local setpoint track the remote setpoint by selecting the Track Remote radio button. The Remote Sp option allows you to select either the Use% radio button (for restricting the setpoint changes to be in percentage) or Use Pv units radio button (for setpoint changes to be in Pv units). • If the Remote Sp is set to Use%, then the controller reads in a value in percentage from a remote source, and using the Pv range calculates the new setpoint. • If the Remote Sp is set to Use Pv units, then the controller reads in a value from a remote source and sets a new setpoint. The remote source’s setpoint must have the same units as the controller Pv. SetPoint Options Group If you select the Track PV radio button, then there is automatic setpoint tracking in manual mode, that sets the value of the setpoint equal to the value of the Pv prior to the controller being placed in the manual mode. This means that upon switching from manual to automatic mode the values of the setpoint and During ramping, if a second setpoint change has been activated, then Ramping Duration time would be restarted for the new setpoint.5-90 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-91 ww ThPv were equal and, therefore, there was an automatic bumpless transfer. Also you have the option not to track the pv, by clicking the No Tracking radio button, when the controller is placed in manual mode. However, when the controller is switched into the automatic mode from manual, there is an internal resetting of the controller errors to ensure that there is an instantaneous bumpless transfer prior to the controller recognizing a setpoint that is different from the Pv. Algorithm Selection Group In the Algorithm Selection group you can select one of three available controller update algorithms: • PID Velocity Form • PID Positional Form (ARW = Anti-Reset Windup) • PID Positional Form (noARW) Velocity or Differential Form In the velocity or differential form the controller equation is given as: where: u(t) = controller output and t is the enumerated sampling instance in time u(t-1) = value of the output one sampling period ago Kc, Ti, and Td = controller parameters h = sampling period The velocity or differential form of the controller should be applied when there is an integral term. When there is no integral term a positional form of the controller should be used. (5.13)u t( ) u t 1–( ) Kc e t( ) e t( )– 1 Ti ----e kh( ) Td e t( ) 2e t 1–( )– e t 2–( )+( ) h ------------------------------------------------------------------+ ++=5-91 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-92 Control Ops ww ThPositional Form In the positional form of the algorithm, the controller output is given by: Here it is important to handle properly the summation term associated with the integral part of the control algorithm. Specifically, the integral term could grow to a very large value in instances where the output device is saturated and the PV is still not able to get to the setpoint. For situations like the one above, it is important to reset the value of the summation to ensure that the output is equal to the limit (upper or lower) of the controller output. As such, when the setpoint is changed to a region where the controller can effectively control, the controller responds immediately without having to decrease a summation term that has grown way beyond the upper or lower limit of the output. This is referred to as an automatic resetting of the control integral term commonly called anti-reset windup. In HYSYS both algorithms are implemented as presented above with one key exception, there is no derivative kick. This means that the derivative part of the control algorithm operates on the process variable as opposed to the error term. As such the control equation given in Equation (5.13) is implemented as follows: (5.14) (5.15) u t( ) Kc e t( ) e t( )– 1 Ti ---- e kh( ) k 0= n ∑ Td e t( ) e t 1–( )–( ) h --------------------------------------+ += u t( ) u t 1–( ) Kc e t( ) e t( )– 1 Ti ----e kh( ) Td pv– 2pv t 1–( ) pv t 2–( )–+( ) h --------------------------------------------------------------------------+ ++=5-92 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-93 ww ThAutotuning Page You can set the autotuning parameters on the Autotuning page. This page consists of two groups: • Autotuner Parameters. Contains the parameters required by the Autotuner to calculate the controller parameters. • Autotuner Results. Displays the resulting controller parameters. You have the option to accept the results as the current tuning parameters. Autotuner Parameters Group In this group, you can specify the controller type by selecting the PID radio button or the PI radio button for the Design Type. In the present autotuner implementation there are five parameters that you must specify, which are as follows: Figure 5.60 Parameter Range Ratio (Ti/Td) (Alpha) Gain ratio (Beta) Phase angle (Phi) For more information about autotuning parameters, refer to the Autotuner Page in Section 5.4.4 - PID Controller. 3.0 α 6.0≤ ≤ 0.10 β 1.0≤ ≤ 30° φ 65°≤ ≤5-93 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-94 Control Ops ww ThIn the present version of the software there are default values specified for the PID tuning. Before starting the autotuner, you must ensure that the controller is in the manual or automatic mode, and the process is relatively steady. If you move the cursor over the tuning parameters field, the Status Bar displays the parameters range. Autotuner Results Group This group displays the results of the autotuner calculation and allows you to accept the results as the current controller setting. The Start Autotuner button activates the tuning calculation, and the Stop Autotuning button abort the calculations. After running the autotuner, you have the option to accept the results either automatically or manually. Selecting the Automatically Accept checkbox sets the resulting controller parameters as the current value instantly. If the Automatically Accept checkbox is inactive, you can specify the calculated controller parameters to be the current setting by clicking the Accept button. Relay hysteresis (h) Relay amplitude (d) Parameter Range 0.01% h 5.0%≤ ≤ 0.5% d 10.0%≤ ≤5-94 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-95 ww ThIMC Design Page The IMC Design page allows you to use the internal model control (IMC) calculator to calculate the operation parameters based on a specified model of the process one is attempting to control. The IMC method is quite common in most of the process industries, and has a very solid theoretical basis. In general, the performance obtained using this design methodology is superior to most of the existing techniques for tuning PIDs. As such, when there is a process model available (first order plus delay) this approach should be used to determine the controller parameters. You must specify a design time constant, which is usually chosen as three times that of the measured process time constant. Figure 5.615-95 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-96 Control Ops ww ThThe IMC Design page has the following two groups described in the table below: As soon as you enter the parameters in the Process Model group, the operation parameters are calculated and displayed in the IMC PID Tuning group. You can accept them as the current tuning parameters by clicking the Update Tuning button. Scheduling Page The Scheduling page gives you the ability to do parameter scheduling. This feature is quite useful for nonlinear processes where the process model changes significantly over the region of operation. The parameter scheduling is activated through the Parameter Schedule checkbox. You can use three different sets of PID Group Description Process Model Contains the parameters for the process model which are required by the IMC calculator. • Process Gain • Process Time Constraint • Process Delay • Design To IMC PID Tuning Displays the operation parameters. Figure 5.625-96 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-97 ww Thparameters if you so desire for three different regions of operation. The following regions of operation can be specified from the Selected Range drop-down list. • Low Range • Middle Range • High Range These regions of operations can be based either on the setpoint, or PV of the controller. The ranges can also be specified, the default values are 0-33%, 33%-66%, and 66%-100% of the selected scheduling signal. You need to specify the middle range limit by defining the Upper and Lower Range Limits. Alarms Page The Alarms page allows you to set alarm limits on all exogenous inputs to and outputs from the controller. The Alarms page contains two groups: • Alarm Levels • Alarms The values of 0 and 100 cannot be specified for both the Lower and the Upper Range Limits. Figure 5.635-97 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-98 Control Ops ww ThAlarm Levels Group The Alarm Level group allows you to set, and configure the alarm points for a selected signal type. There are four alarm points that could be configured: • LowLow • Low • High • HighHigh The alarm points should be specified in the descending order from HighHigh to LowLow points. You cannot specify the value of the Low and LowLow alarm points to be higher than the signal value. Similarly, the High and HighHigh alarm points cannot be specified to a value lower than the signal value. Also, no two alarm points can be specified to a similar value. In addition, you can specify a deadband for a given set of alarms. This can be helpful in situations where the signal is “noisy” to avoid constant triggering of the alarm. If a deadband is specified, you have to specify the alarm points so that their difference is greater than the deadband. At present the range for the allowable deadband is as follows: of the signal range. Alarms Group The Alarms group displays the recently violated alarm for the following signals: The above limits are set internally and are not available for adjustment by the user. Signal Description PV Process Variable OP Output SP Setpoint 0.0% deadband 1.5%≤ ≤5-98 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-99 ww ThSignal Processing Page The Signal Processing page allows you to add filters to any signal associated with the operation, as well as test the robustness of any tuning on the controller. This page consists of two groups: • Signal Filters • Noise Parameters Both of these groups allow you to filter, and test the robustness of the following tuning parameters: • Pv • Op • Sp • Dv • Rs To apply the filter select the checkbox corresponding to the signal you want to filter. Once active you can specify the filter time. As you increase the filter time you are filtering out frequency information from the signal. For example, the signal is noisy, there is a smoothing effect noticed on the plot of the PV. Notice that it is possible to add a filter that makes the controller unstable. In such cases the controller needs to be Figure 5.645-99 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-100 Control Ops ww Threturned. Adding a filter has the same effect as changing the process the controller is trying to control. Activating a Noise Parameter is done the same way as adding a filter. However, instead of specifying a filter time you are specifying a variance. Notice that if a high variance on the PV signal is chosen the controller may become unstable. As you increase the noise level for a given signal you observes a some what random variation of the signal. Initialization Page The Initialization page allows you to set up a sophisticated controller by taking into account the problem of saturation in cascade control, and the need for an appropriate initial output value to ensure a smooth start-up. The Initialization page consists of two features: • Back Initialization • Cascade Control Anti Windup Figure 5.655-100 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-101 ww ThBack Initialization A proper initial OP Value is supplied to the controller to ensure the integration runs smoothly during start up. The Back Initialization button is used to initialize the controller output based on the current position of the executor (for example, a valve, a stream, or another controller). This prevents disturbances in the system during the initial switch-over. Cascade Control Anti Windup A common problem associated with cascade control is saturation. Saturation occurs when the primary controller continues to integrate and send out correction signals to the secondary controller even when the output of the secondary controller is already at its designed limit. As a result, when the primary offset changes (decreases or increases), the primary controller cannot respond accordingly until it overcomes the saturation. By the time this happens, the primary offset is once again too large to be adjusted. This severely reduces the controller performance and even creates an unstable system as the output is always fluctuating. The Cascade Control Anti Windup checkbox allows you to prevent saturation by having the primary controller automatically calculate the feasible output that can be executed by the secondary controller. Once the primary controller detects that the output of the secondary controller has reached its limit (upper or lower), the primary controller will not integrate any further from getting into saturation. Thus, when the offset changes, both the primary and secondary controllers can react immediately without having to wait for the saturation to clear. Stripchart Tab The Stripchart tab allows you to select and create default strip charts containing various variable associated to the operation. For more information on the cascade control strategy, refer to Section 3.3 - Basic Control in the HYSYS Dynamic Modeling guide. Refer to Section 1.3.7 - Stripchart Page/Tab for more information.5-101 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-102 Control Ops ww ThUser Variables Tab The User Variables tab enables you to create and implement your own user variables for the current operation. 5.4.4 PID Controller The Controller operation is the primary means of manipulating the model in Dynamic mode. It adjusts a stream (OP) flow to maintain a specific flowsheet variable (PV) at a certain value (SP). The PID Controller property view contains the following tabs: • Connections • Parameters • Monitor • Stripchart • User Variables The Controller can cross the boundaries between flowsheets, enabling you to sense a process variable in one flowsheet and control a valve in another. Figure 5.66 For more information refer to Section 1.3.8 - User Variables Page/ Tab.5-102 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-103 ww ThConnections Tab The Connections tab allows you to select both the PV and OP. It is comprised of six objects described in the table below: Process Variable Source Common examples of PVs include vessel pressure and liquid level, as well as stream conditions such as flow rate or temperature. Object Description Name Contains the name of the controller. It can be edited by selecting the field and entering the new name. Process Variable Source Object Contains the Process Variable Object (stream or operation) that owns the variable you want to control. It is specified via the Variable Navigator. Process Variable Contains the Process Variable you want to control. Output Target Object The stream or valve, which is controlled by the PID Controller operation Select PV/OP These two buttons open the Variable Navigator which selects the Process Variable and the Output Target Object respectively. Remote Setpoint Source If you are using set point from a remote source, select the remote Setpoint Source associated with the Master controller Figure 5.675-103 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-104 Control Ops ww ThTo attach the Process Variable Source, click the Select PV button. Then select the appropriate object and variable simultaneously, using the Variable Navigator. The Variable Navigator property view allows you to simultaneously select the Object and Variable. Remote Setpoint Source The Remote Setpoint Source drop-down list allows you to select the remote sources from a list of existing operations. The “cascade” mode of the controller no longer exits. Instead what is available now is the ability to switch the setpoint from local to remote. The remote setpoint can come from another object such as a spreadsheet, or another controller cascading down a setpoint. In other words, a master in the classical cascade control scheme. The Process Variable, or PV, is the variable that must be maintained, or controlled at a desired value. Figure 5.68 1. Select flowsheet or subflowsheet. 2. Then select the Object within the respective flowsheet. 3. Then select the object Variable (and the Variable Specific when appropriate). A Spreadsheet cell can also be a Remote Setpoint Source. Refer to Section 1.3.9 - Variable Navigator Property View for information.5-104 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-105 ww ThWhen the spreadsheet exports any PID parameter (gain, Ti, and/or Td) to a PID controller, the controller calls ControllerInitialization(), which is required for smooth switch when the user change the PID parameters. However, if there is an export variable connected an output object, the spreadsheet updates the output every integration step even if the value has not changed. So with the spreadsheet constantly changing the PID parameter values in every integration step, the PID will not be functioning. Output Target Object The Controller compares the Process Variable to the Setpoint, and produces an output signal which causes the manipulated variable to open or close appropriately. Selecting the Output Target Object is done in a similar manner to selecting the Process Variable Source. You are also limited to objects supported by the controller and not currently attached to another controller. The information regarding the control valve or control op port sizing is contained on a sub-view accessed by clicking the Control Valve or Control OP Port button found at the bottom of the PID Controller property view. When PID parameters are exported to a PID controller from a HYSYS spreadsheet, the controller gets initialized at each time step. The Output of the Controller is the control valve which the Controller manipulates in order to reach the set point. The output signal, or OP, is the desired percent opening of the control valve, based on the operating range which you define in the Control Valve property view. The Control Valve button (at the bottom right corner of the controller operation property view) appears if the OP is a stream.5-105 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-106 Control Ops ww ThParameters Tab The Parameters tab contains the following pages: • Configuration • Advanced • Autotuner • IMC Design • Scheduling • Alarms • PV Conditioning • Signal Processing • FeedForward • Model Testing • Initialization Configuration Page The Configuration page allows you to set the process variable range, controller action, operating mode, and depending on the The Control OP Port button (at the bottom right corner of the controller operation property view) appears when the OP is not a stream and there a range of specified values is required.5-106 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-107 ww Thmode, either the SP or OP, as well as tune the controller. PV and SP The PV (or Process Variable) is the measured variable, which the controller is trying to keep at the Setpoint. The SP (or Setpoint) is the value of the Process Variable, which the Controller is trying to meet. Depending on the Mode of the Controller, the SP is either entered by the user or displayed only. For the Controller to become operational, you must: 1. Define the minimum and maximum values for the PV (the Controller cannot switch from Off mode unless PVmin and PVmax are defined). 2. Once you provide these values (as well as the Control Valve span), you may select the Automatic mode, and give a value for the Setpoint. HYSYS converts the PV range into a 0-100% range, which is then used in the solution algorithm. The following equation is used to translate a PV value into a percentage of the Figure 5.69 HYSYS uses the current value of the PV as the set point by default, but you may change this value at any time. Without a PV span, the Controller cannot function.5-107 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-108 Control Ops ww Thrange: OP The OP (or Output) is the percent opening of the control valve. The Controller manipulates the valve opening for the output stream in order to reach the set point. HYSYS calculates the necessary OP using the controller logic in all modes with the exception of Manual. In Manual mode, you may input a value for the output, and the setpoint becomes whatever the PV is at the particular valve opening you specify. Modes The Controller operates in any of the following modes: The mode of the controller can also be set on the Face Plate. Execution You can select where the signal from the controller is sent using the drop-down list in the Execution field. You have two selections: (5.16) Controller Mode Description Off The controller does not manipulate the control valve, although the appropriate information is still tracked. Manual Manipulates the controller output manually. Auto The controller reacts to fluctuations in the Process Variable, and manipulates the output according to the logic defined by the tuning parameters. Casc The main controller reacts to the fluctuations in the Process Variable, and sends signals to the slave controller (Remote Setpoint Source). Indicator Allows you to simulate the controller without controlling the process. PV %( ) PV PVmin– PVmax PVmin– -------------------------------------⎝ ⎠ ⎛ ⎞ 100= Refer to Section 5.13.2 - Controller Face Plate for more information on Face Plate.5-108 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-109 ww Th• Internal. Confines the signals generated to stay within HYSYS. • External. Sends the signals to a DCS, if a DCS is connected to HYSYS. Action There are two options for the Action of the controller, which are described in the table below: The Controller equation given above applies to a Reverse-acting Controller. That is, when the PV rises above the SP, the error becomes negative and the OP decreases. For a Direct-response Controller, the OP increases when the PV rises above the SP. This action is made possible by replacing Kp with -Kp in the Controller equation. A typical example of a Reverse Acting controller is in the temperature control of a Reboiler. In this case, as the temperature in the vessel rises past the SP, the OP decreases, in effect closing the valve and hence the flow of heat. Some typical examples of Direct-Acting and Reverse-Acting control situations are given below. • Direct - Acting Controller Example 1: Flow Control in a Tee Suppose you have a three-way tee in which a feed stream is being split into two exit streams. You want to control the flow of exit stream Product 1 by manipulating the flow of stream Product 2: • Direct - Acting Controller Example 2: Pressure Control in a Vessel Controller Action Description Direct When the PV rises above the SP, the OP increases. When the PV falls below the SP, the OP decreases. Reverse When the PV rises above the SP, the OP decreases. When the PV falls below the SP, the OP increases. Process Variable and Setpoint Product 1 Flow Output Product 2 Flow When Product 1 Flow rises above the SP The OP increases, in effect increasing the flow of Product 2 and decreasing the flow of Product 1. When Product 1 Flow falls below the SP The OP decreases, in effect decreasing the flow of Product 2 and increasing the flow of Product 1.5-109 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-110 Control Ops ww ThSuppose you were controlling the pressure of a vessel V- 100 by adjusting the flow of the outlet vapour, SepVapour: • Reverse - Acting Controller Example 1: Temperature Control in a Reboiler Reverse-Acting control may be used when controlling the temperature of reboiler R-100 by adjusting the flow of the duty stream, RebDuty: • Reverse - Acting Controller Example 2: Pressure Control in a Reboiler Another example where Reverse-Acting control may be used is when controlling the stage pressure of a reboiler R-100 by adjusting the flow of the duty stream, RebDuty: Process Variable and Setpoint V-100 Vessel Pressure Output SepVapour Flow When V-100 Pressure rises above the SP The OP increases, in effect increasing the flow of SepVapour and decreasing the Pressure of V-100. When V-100 Pressure falls below the SP The OP decreases, in effect decreasing the flow of SepVapour and increasing the Pressure of V-100. Process Variable and Setpoint R-100 Temperature Output RebDuty Flow When R-100 Temperature rises above the SP The OP decreases, in effect decreasing the flow of RebDuty and decreasing the Temperature of R-100. When R-100 Temperature falls below the SP The OP increases, in effect increasing the flow of RebDuty and increasing the Temperature of R-100. Process Variable and Setpoint R-100 Stage Pressure Output RebDuty Flow When R-100 Stage Pressure rises above the SP The OP decreases, in effect decreasing the flow of RebDuty and decreasing the Stage Pressure of R-100. When R-100 Stage Pressure falls below the SP The OP increases, in effect increasing the flow of RebDuty and increasing the Stage Pressure of R-100.5-110 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-111 ww ThSP Mode You have the ability to switch the setpoint from local to remote. Essentially, there are two internal setpoints in the controller, the first is the local setpoint where you can manually specify the setpoint via the property view (interface), and the other is the remote setpoint which comes from another object such as a spreadsheet or another controller cascading down a setpoint. In other words, a master in the classical cascade control scheme. Tuning Parameters and Algorithm Selection Groups From the Algorithm Type selector, you can choose PID algorithms of four possible types or vendors: • Hysys • Honeywell • Foxboro • Yokogawa each of them offering a set of options or Algorithm Subtypes. See the HYSYS Online help for specific details on these options. Advanced Page The Advanced page contains the following four groups: Group Description Set Point Ramping Allows you to specify the ramp target and duration. SetPoint Options Contains the options for setpoint tracking. Sp and Op Limits Allows you to set the upper and lower limits for set point and output targets. Algorithm Selection Contains the PID controller algorithms for output calculation.5-111 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-112 Control Ops ww ThSet Point Ramping Group The setpoint ramping function has been modified in the present PID controllers. Now it is continuous (in other words, when enabled by clicking the Enable button), the setpoint changes over the specified period of time in a linear manner. The Set Point Ramping group contains the following two fields: • Target SP. Contains the Setpoint you want the Controller to have at the end of the ramping interval. When the ramping is disabled, the Target SP field displays the same value as the SP field on the Configuration page. Figure 5.70 Setpoint ramping is only available in Auto mode.5-112 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-113 ww Th• Ramp Duration. Contains the time interval you want to complete setpoint change in. There are also two buttons available in this group: • Enable. Activates the ramping process • Disable. Stops the ramping process. While the controller is in ramping mode, you can change the setpoint as follows: • Enter a new setpoint in the Target SP field, on this page. • Enter a new setpoint in the SP field, on the Configuration page. During the setpoint ramping the Target SP field, shows the final value of the setpoint whereas the SP field, on the Configuration page, shows the current setpoint seen internally by the control algorithm. An example, if you click the Enable button and enter values for the two parameters in the Set Point Ramping group, the Controller switches to Ramping mode and adjust the Setpoint linearly (to the Target SP) during the Ramp Duration, see Figure 5.72. Figure 5.71 During ramping, if a second setpoint change has been activated, then Ramping Duration time would be restarted for the new setpoint. Ramping Duration = RTSP SP(t) t t+RT Time Target SP Controller Ramping5-113 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-114 Control Ops ww ThFor example, suppose your current SP is 100, and you want to change it to 150. Rather than creating a sudden, large disruption by manually changing the SP while in Automatic mode, click the Enable button and enter an SP of 150 in the Target SP input cell. Make the SP change occur over, say, 10 minutes by entering this time in the Ramp Duration cell. HYSYS adjusts the SP from 100 to 150 linearly over the 10 minute interval. SetPoint Options Group In the past the PID controllers implemented an automatic setpoint tracking in manual mode, in other words, the value of the setpoint was set equal to the value of the PV when the controller was placed in manual mode. This meant that upon switching, the values of the setpoint and PV were equal, and therefore there was an automatic bumpless transfer. In the present controller setup, the Sp (Manual) option allows PV tracking, by selecting the No Tracking radio button, when the controller is in manual mode. However, when the controller is switched into the automatic mode from manual, there is an internal resetting of the controller errors to ensure that there is an instantaneous bumpless transfer prior to the controller recognizing a setpoint that is different from the PV. If the Track PV radio button is selected than there would be an automatic setpoint tracking. The Local Sp option allows you to disable the tracking for the local setpoint when the controller is placed in manual mode. You can also have the local setpoint track the remote setpoint by selecting the Track Remote radio button. The Remote Sp option allows you to select either the Use% radio button (for restricting the setpoint changes to be in percentage) or Use Pv units radio button (for setpoint changes to be in PV units). • Use%. If this radio button is selected, then the controller reads in a value in percentage from a remote source and uses the PV range to calculate the new setpoint.5-114 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-115 ww Th• Use Pv units. If this radio button is active, then the controller reads in a value from a remote source, and is used as the new setpoint. The remote sources setpoint must have the same units as the controller PV. An example, it is desired to control the flowrate in a stream with a valve. A PID controller is used to adjust the valve opening to achieve the desired flowrate, that is set to range between 0.2820 m3/h and 1.75 m3/h. A spreadsheet is used as a remote source for the controller setpoint. A setpoint change to 1 m3/h from the current Pv value of 0.5 m3/h is made. The spreadsheet internally converts the new setpoint as m3/s (in other words, 1/ 3600 = 0.00028 m3/s) and pass it to the controller, which converts it back into m3/h (in other words, 1 m3/h). The controller uses this value as the new setpoint. If the units are not specified, then the spreadsheet passes it as 1 m3/s, which is the base unit in HYSYS, and the controller converts it into 3600 m3/h and pass it on to the SP field as the new setpoint. Since the PV maximum value cannot exceed 1.75m3/h, the controller uses the maximum value (1.75 m3/h) as the new setpoint. Sp and Op Limits Group This group enables you to specify the output and setpoint limits. The output limits ensure that a predetermined minimum or maximum output value is never exceeded. In the case of the setpoint, the limits enforce an acceptable the range of values that could be entered via the interface or from a remote source. When the Enable Op Limits in Manual Mode checkbox is selected, you can enable the set point and output limits when in manual mode. Algorithm Selection Group In the Algorithm Selection group, you can select one of the three available controller update algorithms: • PID Velocity Form • PID Positional Form (ARW = Anti-Reset Windup) • PID Positional Form (noARW) • PID Manual Loading5-115 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-116 Control Ops ww ThVelocity or Differential Form In the velocity or differential form, the controller equation is given as: where: u(t) = controller output and t is the enumerated sampling instance in time u(t-1) = value of the output one sampling period ago Kc, Ti, and Td = controller parameters h = sampling period Positional Form In the positional form of the algorithm, the controller output is given by: Here it is important to handle properly the summation term associated with the integral part of the control algorithm. Specifically, the integral term could grow to a very large value in instances where the output device is saturated, and the PV is still not able to get to the setpoint. For situations like the one above, it is important to reset the value of the summation to ensure that the output is equal to the limit (upper or lower) of the controller output. As such, when the setpoint is changed to a (5.17) The velocity or differential form of the controller should be applied when there is an integral term. When there is no integral term a positional form of the controller should be used. (5.18) u t( ) u t 1–( ) Kc e t( ) e t 1–( ) 1 Ti ----e t( )h Td e( t( ) 2e t 1–( ) e t 2–( ) )+– h ------------------------------------------------------------------- + + –+= u t( ) Kc e t( ) 1 Ti ---- e i( )h i 1= n ∑ Td e t( ) e t 1–( )–( ) h --------------------------------------+ +=5-116 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-117 ww Thregion where the controller can effectively control, the controller responds immediately without having to decrease a summation term that has grown way beyond the upper or lower limit of the output. This is referred to as an automatic resetting of the control integral term commonly called anti-reset windup. In HYSYS, both algorithms are implemented as presented above with one key exception, there is no derivative kick. This means that the derivative part of the control algorithm operates on the process variable as opposed to the error term. As such the control equation given in Equation (5.19) is implemented as follows: Manual Loading Station In the manual loading station algorithm the output, u(t), is equal to the input y(t). Here the setpoint plays no role in the algorithm, instead whatever the percent input value is going into the controller, the output follows the same percent value. As in the case of the other control algorithms the output is bounded by an upper and lower limit of 100% and 0.0% respectively. OP Override The INIT box usually indicates that the OP value displayed on the controller has been back-calculated either from another controller or a selector block.The OP value is determined based on the Kc term and the PV range specified on the controller. (5.19) (5.20) In Manual mode, you can set the OP like regular PID. In Auto mode, the OP equals to PV based on PV range. u t( ) u t 1–( ) Kc e t( ) e t( )– 1 Ti ----e kh( ) Td pv– 2pv t 1–( ) pv t 2–( )–+( ) h --------------------------------------------------------------------------+ ++= u t( ) y t( )=5-117 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-118 Control Ops ww ThA controller can show INIT under two circumstances: • The controller is the master controller in a master-slave configuration and the slave controller is not in cascade mode. The OP for the master controller is back calculated, allowing for bumpless transfer when switching controller modes. The INIT message serves to notify the user that the OP is being calculated elsewhere. • The controller is one of two (or more) controllers feeding their respective OPs into a selector block. The controller whose OP has not been selected will show INIT to indicate that its OP has been calculated by the selector. Again, this is to facilitate a bumpless transfer when the selected controller changes. The unselected PID Controller/Selector Block calculates the Output as follows: The unselected PID is tracking the selector output so that it can be reselected by the Selector Block when the PV reaches a certain range. The output of the unselected PID is calculated based on the current output of the selector: Autotuner Page The autotuner function provides tuning parameters for the PID controller based on gain and phase margin design. The autotuner itself can be viewed as another controller object that has been embedded into the PID controller. The autotuner is based on a relay feedback technique, and by default incorporates a relay with hysteresis (h). The figure below shows an example of a relay with an amplitude (d) and hysteresis (h) is plotted on a graph of Output u(t) (5.21) (5.22) OPcontroller OPselector Kc SP PV– PVRange ------------------------⎝ ⎠ ⎛ ⎞ 100%×–= OPPID OPselector ΔMove+=5-118 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-119 ww Thversus Error Input into the relay e(t) plot. This type of relay is a double-valued nonlinearity, sometimes referred to as having memory. In other words, the value of the output depends on the direction that the process error is coming. Relays are quite common in automation and control, and this technique for tuning PID controllers has been around at least 10 years now (see Cluett and Goberdhansingh, Automatica, 1992). The technique has a strong theoretical base and in general works well in practice but it is not a panacea. The PID controller parameters that are obtained from the autotuner are based on a design methodology that makes use of a gain margin at a specified phase angle. This design is quite similar to the regular gain and phase margin methodology except that it is more accurate since the relay has the ability to determine points in the frequency domain accurately and quickly. Also, the relay experiment is controlled and does not take a long time during the tuning cycle. The Autotuner page allows you to specify the autotuning parameters. Figure 5.725-119 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-120 Control Ops ww ThThe page contains two groups: • Autotuner Parameters. Contains the parameters required by the Autotuner to calculate the controller parameters. • Autotuner Results. Displays the resulting controller parameters. You have the option to accept the results as the current tuning parameters Autotuner Parameters Group In this group, you can specify the controller type by selecting the PID or PI radio button for the Design Type. In the present autotuner implementation there are four parameters that the you must specify which are as follows: Figure 5.73 Parameter Range Ratio (Ti/Td) (Alpha) Gain ratio (Beta) Phase angle (Phi) Relay hysteresis (h) Relay amplitude (d) 3.0 α 6.0≤ ≤ 0.10 β 1.0≤ ≤ 30° φ 65°≤ ≤ 0.01% h 5.0%≤ ≤ 0.5% d 10.0%≤ ≤5-120 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-121 ww ThAutotuner Results Group This group displays the results of the autotuner calculation, and allows you to accept the results as the current controller setting. The Start Autotuner button activates the tuning calculation, and the Stop Autotuning button abort the calculations. After running the autotuner, you have the option to accept the results either automatically or manually. Selecting the Automatically Accept checkbox sets the resulting controller parameters as the current value instantly. If the Automatically Accept checkbox is inactive, you can specify the calculated controller parameters to be the current setting by clicking the Accept button. An example, while a case is running in a dynamic simulation, change the controller mode to either Manual or Automatic. On the Autotuner page, select the Design Type and specify the tuning parameters (or use the default values). Click the Start Autotuner button and wait for the Autotuner to display the results. To accept the results and copy them in the Current Tuning group on the Configuration page, click the Accept button. IMC Design Page The IMC Design page allows you to use the internal model control (IMC) calculator to calculate the PID parameters based In the present version of the software there are default values specified for the PID tuning. Before starting the autotuner, you must ensure that the controller is in the manual or automatic mode, and the process is relatively steady. If you move the cursor over the tuning parameters field, the Status Bar displays the parameters range. HYSYS suggest using the auto tuning results as a guideline and should not be treated as a catholicon. It is recommended to specify the Autotuning parameters to suit your process requirement.5-121 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-122 Control Ops ww Thon a specified model of the process one is attempting to control. The IMC method is quite common in most of the process industries and has a very solid theoretical basis. In general, the performance obtained using this design methodology is superior to most of the existing techniques for tuning PIDs. As such, when there is a process model available (first order plus delay) this approach should be used to determine the controller parameters. You must specify a design time constant, which is usually chosen as three times that of the measured process time constant. The IMC Design page has the following two groups: As soon as you enter the parameters in the IMC Design Parameters group, the controller parameters are calculated and displayed in the IMC PID Tuning group. You can accept them as the current tuning parameters by clicking the Update Tuning button. Figure 5.74 Group Description IMC Design Parameters Contains the parameters for the process model which are required by the IMC calculator. • Process Gain • Process Time Constraint • Process Delay • Design To IMC PID Tuning Displays the PID controller parameters.5-122 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-123 ww ThScheduling Page The Scheduling page gives you the ability to do parameter scheduling. The parameter scheduling is quite useful for nonlinear processes where the process model changes significantly over the region of operation. The parameter scheduling is activated through the Parameter Schedule checkbox. You can use three different sets of PID parameters, if you so desire for three different regions of operation. The following regions of operation can be specified from the Selected Range drop-down list. • Low Range • Middle Range • High Range These regions of operations can be based either on the setpoint or PV of the controller. The ranges can also be specified, the default values are 0-33%, 33%-66%, and 66%-100% of the selected scheduling signal. You need to specify the middle range limit by defining the Upper and Lower Range Limits. Figure 5.75 The values of 0 and 100 cannot be specified for both the Lower and the Upper Range Limits.5-123 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-124 Control Ops ww ThAlarms Page The Alarms page allows you to set alarm limits on all exogenous inputs to and outputs from the controller. The page contains two groups and one button: • Alarm Levels • Alarms • Reset Alarm button Alarm Levels Group The Alarm Level group allows you to set, and configure the alarm points for a selected signal type. There are four alarm points that can be configured: • LowLow • Low • High • HighHigh The alarm points should be specified in the descending order from HighHigh to LowLow points. You cannot specify the value of the Low and LowLow alarm points to be higher than the signal value. Similarly, the High and HighHigh alarm points cannot be specified a value lower than the signal value. Also, no two alarm points can have a similar value. In addition, you can specify a Figure 5.765-124 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-125 ww Thdeadband for a given set of alarms. This can be helpful in situations where the signal is “noisy” to avoid constant triggering of the alarm. If a deadband is specified, you have to specify the alarm points so that their difference is greater than the deadband. At present the range for the allowable deadband is as follows: of the signal range. Alarms Group The Alarms group display the recently violated alarm for the following signals: Reset Alarm Button When the deadband has been set, it is possible that an alarm status is triggered and the alarm does not disappear until the band has been exceeded. The Reset Alarm button allows the alarm to be reset when within the deadband. An example, it is desired to control the flowrate through a valve within the operating limits. Multiple alarms can be set to alert you about increases or decreases in the flowrate. For the purpose of this example, you are specifying low and high alarm limits for the process variable signal. Assuming that the normal flowrate passing through the valve is set at 1.2 m3/h, the low alarm should get activated when the flowrate falls below 0.7 m3/ h. Similarly, when the flowrate increases to 1.5 m3/h the high The above limits are set internally and are not available for adjustment by the user. Signal Description PV Process Variable OP Output SP Setpoint DV Disturbance Variable (this is available for the feedforward controller in the Future) RS Remote Setpoint 0.0% deadband 1.5%≤ ≤5-125 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-126 Control Ops ww Thalarm should get triggered. To set the low alarm, first make sure that the Pv Signal is selected in the Signal drop-down list. Specify a value of 0.7 m3/ h in the cell beside the Low alarm level. Follow the same procedure to specify a High alarm limit at 1.5 m3/h. If you want to re-enter the alarms, click the Reset Alarm button to erase all the previously specified alarms. PV Conditioning Page The PV Conditioning page allows you to simulate the failure of the controller input signal. This page consists of three groups: • PV Sampling Failure • Sample and Hold PV • Stream Temperature Filter Figure 5.775-126 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-127 ww ThPV Sampling Failure Group The PV Sampling Failure group consists of three radio buttons: None, Fixed Signal, and Bias. The options presented to you changes with respect to the radio button chosen. • When the None radio button is selected, the property view is as seen in the figure above, with only the Actual PV and Failed PV values displayed. • When Fixed Signal radio button is selected, the PV Sampling Failure group appears as follows. The Failed Input Signal To parameter allows you to fix the failed input signal using either the PV units or a Percentage of the PV range. • When the Bias radio button is selected the PV Sampling Failure group appears as follows. The PV Sampling Failure group allows you to drift the input signal. The parameters allow you to bias the signal and create a drift over a period of time. To start the drift simply click the Start Drift button. Sample and Hold PV Group The Sample And Hold PV group allows you to take a PV sample and hold this value for a specified amount of time. Figure 5.78 Figure 5.795-127 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-128 Control Ops ww ThStream Temperature Filter Group The Stream Temperature Filter group allows you to calculate the temperature of a low flow rate stream by applying a first order transient filter with a user-specified ambient time constant. By default, the Apply Filter checkbox is cleared. You can apply the temperature filter by selecting the Apply Filter checkbox. To set the conditions for the filter, you will need to specify the following: • First Order Time Constant. First order exponential time constant applied to the filter when the flow rate is within the acceptable range (in other words, above the Cut Off Flow value). By default, the First Order Time Constant is 15 seconds. If the field is empty, or you enter a value of zero, then no filtering is applied. • Ambient Time Constant. Time constant applied to the filter when the flow rate of a stream drops below the Cut Off Flow value. It determines how long it takes for the actual temperature of the stream to reach the ambient temperature. By default, the ambient time constant is 3600 seconds. If the field is empty, or you enter a value of zero, the temperature value is calculated from the flash and no filtering is applied. • Cut Off Flow. Switch-over point at which the temperature filter applies the ambient time constant in calculating the temperature of the stream. The Cut Off Flow value is expressed in molar flow, and the default value is 1e-5 kmol/s. If the stream flow rate is above the Cut Off Flow value, the controller automatically switches back to the normal flash calculations which only apply the First Order Time Constant. The Ambient Time Constant is applied when the flow rate drops below the Cut Off Flow value with the temperature ramping to ambient over some slow periods. Figure 5.805-128 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-129 ww ThSignal Processing Page The Signal Processing page allows you to add filters to any signal associated with the PID controller, as well as test the robustness of any tuning on the controller. This page is made up of two groups: Signal Filters and Noise Parameters. Both of these groups allows you to filter and test the robustness of the following tuning parameters: • Pv • Op • Sp • Dv • Rs To apply the filter, select the checkbox corresponding to the signal you want to filter. Once active you can specify the filter time. As you increase the filter time you are filtering out frequency information from the signal. It is possible to add a filter that makes the controller unstable. In such cases the controller needs to be returned. Adding a filter has the same effect as changing the process the controller is trying to control. For example, if the signal is noisy, there is a smoothing effect noticed on the plot of the PV when the filter is applied. Activating a Noise Parameter is done the same way as adding a Figure 5.815-129 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-130 Control Ops ww Thfilter. However, instead of specifying a filter time you are specifying a variance. Notice that if a high variance on the PV signal is chosen the controller may become unstable. As you increase the noise level for a given signal you observe a some what random variation of the signal. FeedForward Page The FeedForward page enables you to design a controller that takes into account measured disturbances. The Disturbance Variable Source group allows you to select a disturbance variable, and minimum and maximum variables. The disturbance variable is specified by clicking the Select Dv button. This opens the Variable Navigator. The FeedForward Parameters group allows you to set the Operating Mode for both the PID controller and the FeedForward controller and tune the controller. All FeedForward controllers require a process model in order for the controllers to work properly. Presently HYSYS uses a model Figure 5.82 To enable feedforward control you must select the Enable FeedForward checkbox.5-130 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-131 ww Ththat results in a lead-lag process. Therefore, there are four parameters available. The equation model for the FeedForward controller is as follows: where: Kp = gain = time constant d = deadtime or delay Model Testing Page The Model Testing page allows you to set the following parameters for generating data from the plant model. • Signal Type offers two options. - PRBS is simple to use for model identification. - STEP is more recognized in practical process applications. • Signal Variation Amplitude determines how much the output variables are changed to identify the model. The default value is 5%. • Time Interval determines how often data points are recorded during the testing phase. • Testing Time Length determines the total time period to apply the testing. The value should be larger than the time constant of the system. Select the Enable Test check box in the Monitor table to perform the model testing when the integrator starts. Click Reset Test to reset the model testing back to the beginning. After the testing is complete, click Save Test Result to save the testing results. The results will be saved as three files: • *_sp.vec for SP • *_pv.vec for PV (5.23)G s( ) Kp τ1s 1+( )e ds– τ2s 1+ -------------------------------= τ 5-131 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-132 Control Ops ww Th• *_op.vec for OP Initialization Page The Initialization page of the PID controller contains the same information as the one for the ratio controller. For more information on back initialization and saturation, refer to Section 5.4.3 - Ratio Controller.5-132 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-133 ww ThMonitor Tab A quick monitoring of the response of the Process Variables, Setpoint, and Output can be seen on the Monitor tab. This tab allows you to monitor the behaviour of process variables in a graphical format while calculations are proceeding. The Monitor tab displays the PV, SP, and Op values in their relevant units versus time. You can customize the default plot settings using the object inspection menu, which is available only when you right-click on any spot on the plot area. The object inspection menu contains the following options: Figure 5.83 Item Description Graph Control Opens the Graph Control Property View to modify many of the plot characteristics. Turn Off/On Cross Hair Turns the cross hair either on or on. Turn Off/On Vertical Cross Hair Turns the vertical cross hair either on or on. Turn Off/On Horizontal Cross Hair Turns the horizontal cross hair either on or on. Values Off/On Displays the current values for each of the variables, if turned on. Copy to Clipboard Copies the current plot to the clipboard with the chosen scale size. 5-133 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-134 Control Ops ww ThA quick way to customize your plot is to use the Monitor Properties property view, which can be access by clicking the Properties button. There are three group available on the Monitor Properties property view, which are described as follows: • Data Capacity. Allows you specify the type and amount of data to be displayed. You can also select the data sampling rate. • Left Axis. Gives you an option to display either the PV and SP or the Error data on the left axis of the plot. You can also customize the scale or let HYSYS auto scale it according to the current values. • Right Axis. Gives you an option to either customize the right axis scale or let HYSYS auto scale it according to the current OP value. Stripchart Tab The Stripchart tab allows you to select and create default strip charts containing various variable associated to the operation. User Variables Tab The User Variables tab enables you to create and implement your own user variables for the current operation. Print Plot Prints the plot as it appears on the screen. Print Setup Allows you to access the typical Windows Print Setup. The Windows Print Setup allows you to select the printer, the paper orientation, the paper size, and paper source. Item Description Refer to Section 1.3.7 - Stripchart Page/Tab for more information. For more information refer to Section 1.3.8 - User Variables Page/ Tab.5-134 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-135 ww Th5.4.5 MPC Controller The “Model Predictive Control” (MPC) controller addresses the problem of controlling processes that are inherently multi- variable and interacting in nature, in other words, one or more inputs affects more than one output. The MPC property view contains the following tabs: • Connections • Parameters • MPC Setup • Process Models • Stripchart • User Variables Figure 5.84 The current version of the MPC implementation does not handle the problem of processes with constraints - a future release is capable of handling that class of problems.5-135 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-136 Control Ops ww ThConnections Tab The Connections tab is comprised of six objects that allow you to select the Process Variable Source, Output Target Object, and Remote SP. Figure 5.85 Object Description Name Contains the name of the controller. It can be edited by selecting the field and entering the new name. Process Variable Source Object Contains the Process Variable Object (stream or operation) that owns the variable you want to control. It is specified via the Variable Navigator. Process Variable Contains the Process Variable you want to control. Output Target Object The stream or valve which is controlled by the MPC Controller operation Remote Setpoint Source If you are using set point from a remote source, select the remote Setpoint Source associated with the Master controller Select PV/OP/SP These three buttons open the Variable Navigator which selects the Process Variable, the Output Target Object, the Remote Setpoint Source respectively. PV/OP/SP These three fields allow you to select a specific Process Variable, Output Target Object, and Remote Setpoint Source respectively.5-136 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-137 ww ThProcess Variable Source Common examples of PVs include vessel pressure and liquid level, as well as stream conditions such as flow rate or temperature. To attach the Process Variable Source, click the Select PV button. Then select the appropriate object and variable simultaneously, using the Variable Navigator. The Variable Navigator allows you to simultaneously select the Object and Variable. Remote Setpoint The “cascade” mode of the controller no longer exits. Instead what is available now is the ability to switch the setpoint from local to remote. The remote setpoint can come from another object such as a spread-sheet or another controller cascading down a setpoint. In other words, a master in the classical cascade control scheme. The Select Sp button allows you to select the remote source using the Variable Navigator. Output Target Object The Controller compares the Process Variable to the Setpoint, and produces an output signal which causes the manipulated variable to open or close appropriately. The Process Variable, or PV, is the variable that must be maintained or controlled at a desired value. A Spreadsheet cell can also be a Remote Setpoint Source. Refer to Section 1.3.9 - Variable Navigator Property View for information.5-137 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-138 Control Ops ww ThSelecting the Output Target Object is done in a similar manner to selecting the Process Variable Source. You are also limited to objects supported by the controller and not currently attached to another controller. The information regarding the control valve or control op port sizing is contained on a sub-view accessed by clicking the Control Valve or Control OP Port button found at the bottom of the MPC Controller property view. Parameters Tab The Parameters tab contains the following pages: • Operation • Configuration • Advanced • Alarms The Output of the Controller is the control valve which the Controller manipulates in order to reach the set point. The output signal, or OP, is the desired percent opening of the control valve, based on the operating range which you define in the Control Valve property view. The Control Valve button (at the bottom right corner of the logical operation property view) appears if the OP is a stream. The Control OP Port button (at the bottom right corner of the logical operation property view) appears when the OP is not a stream and there a range of specified values is required.5-138 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-139 ww ThOperation Page The Operation page allows you to set the execution type, controller mode and depending on the mode, either SP or OP. Mode Group The Controller operates in any of the following modes: • Off. The Controller does not manipulate the control valve, although the appropriate information is still tracked. • Manual. Manipulates the Controller output manually. • Automatic. The Controller reacts to fluctuations in the Process Variable and manipulates the Output according to the logic defined by the tuning parameters. You can select where the signal from the controller is sent using the drop-down list in the Execution field. You have two selections: • Internal. Confines the signals generated to stay within HYSYS. • External. Sends the signals to a DCS, if a DCS is connected to HYSYS. Figure 5.86 The mode of the controller may also be set on the Face Plate, refer to Section 5.13.2 - Controller Face Plate for more information.5-139 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-140 Control Ops ww ThSps and Pvs Group Displays the Setpoint (SP) and Process Variable (PV) for each of the controllers inputs. Depending on the Mode of the controller the SP can either be input by you or is determined by HYSYS. Outputs Group The Output (OP) is the percent opening of the control valve. The Controller manipulates the valve opening for the Output Stream in order to reach the set point. HYSYS calculates the necessary OP using the controller logic in all modes with the exception of Manual. In Manual mode, you may enter a value for the Output, and the Setpoint becomes whatever the PV is at the particular valve opening you specify. This can be done for all of the inputs to the controller. Configuration Page The Configuration page allows to specify the process variable, setpoint, and output ranges. Figure 5.875-140 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-141 ww ThPV: Min and Max For the Controller to become operational, you must: 1. Define the minimum and maximum values for the PV (the Controller cannot switch from Off mode unless PVmin and PVmax are defined). 2. Once you provide these values (as well as the Control Valve span), you can select the Automatic mode and give a value for the Setpoint. HYSYS converts the PV range into a 0-100% range, which is then used in the solution algorithm. The following equation is used to translate a PV value into a percentage of the range: SP Low and High Limits You can specify the higher and lower limits for the Setpoints to reflect your needs and safety requirements. The Setpoint limits enforce an acceptable range of values that could be entered via the interface or from a remote source. By default the PVs min and max values are used as the SPs low and high limits, respectively. Op Low and High Limits You can specify the higher and lower limits for all the outputs. The output limits ensure that a predetermined minimum or maximum output value is never exceeded. By default 0% and 100% is selected as a low and a high of limit, respectively for all the outputs. HYSYS uses the current value of the PV as the set point by default, but you can change this value at any time. Without a PV span, the Controller cannot function. (5.24)PV %( ) PV PVmin– PVmax PVmin– -------------------------------------⎝ ⎠ ⎛ ⎞ 100=5-141 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-142 Control Ops ww ThAdvanced Page The Advanced page contains the following three groups: The setpoint signal is specified in the Selected Sp Signal # field by clicking the up or down arrow button , or by typing the appropriate number in the field. Depending upon the signal selected, the page displays the respective setpoint settings. When the Enable Op Limits in Manual Mode checkbox is selected, you can enable the set point and output limits when in manual mode. Group Description Setpoint Ramping Allows you to specify the ramp target and duration. Setpoint Mode Contains the options for setpoint mode and tracking, as well as the option for remote setpoint. Setpoint Options Contains the option for setpoint tracking only in manual mode. Figure 5.885-142 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-143 ww ThSetpoint Ramping Group The setpoint ramping function has been modified in the present MPC controllers. Now it is continuous, in other words, when set to on by clicking the Enable button, the setpoint changes over the specified period of time in a linear manner. The Setpoint Ramping group contains the following two fields: • Target SP. Contains the Setpoint you want the Controller to have at the end of the ramping interval. When the ramping is turn off, the Target SP field display the same value as SP field on the Configuration page. • Ramping Duration.Contains the time interval you want to complete setpoint change in. Besides these two fields there are also two buttons available in this group: • Enable. Activates the ramping process. • Disable. Stops the ramping process. While the controller is in ramping mode, you can change the setpoint as follows: • Enter a new setpoint in the Target SP field. • Enter a new setpoint in the SP field, on the Operation page. Setpoint ramping is only available in Auto mode. Figure 5.89 Ramping Duration = RTSP SP(t) t t+RT Time Target SP Controller Ramping5-143 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-144 Control Ops ww ThDuring the setpoint ramping the Target SP field shows the final value of the setpoint whereas the SP field, on the Operation page, shows the current setpoint seen internally by the control algorithm. An example, if you click the Enable button and enter values for the two parameters in the Setpoint Ramping group, the Controller switches to Ramping mode and adjusts the Setpoint linearly (to the Target SP) during the Ramp Duration, see Figure 5.90. For example, suppose your current SP is 100, and you want to change it to 150. Rather than creating a sudden large disruption by manually changing the SP while in Automatic mode, click the Enable button and enter the SP of 150 in the Target SP input field. Make the SP change occur over, say, 10 minutes by entering this time in the Ramp Duration field. HYSYS adjusts the SP from 100 to 150 linearly over the 10 minute interval. Setpoint Mode Group You now have the ability to switch the setpoint from local to remote using the Setpoint mode radio buttons. Essentially, there are two internal setpoints in the controller, the first is the local setpoint where you can manually specify the setpoint via the property view (interface), and the other is the remote setpoint which comes from another object such as a spreadsheet or another controller cascading down a setpoint. In other words, a master in the classical cascade control scheme. The Sp Local option allows you to disable the tracking for the local setpoint when the controller is placed in manual mode. You can also have the local setpoint track the remote setpoint by selecting the Track Remote radio button. During ramping, if a second setpoint change has been activated, then Ramping Duration time would be restarted for the new setpoint.5-144 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-145 ww ThThe Remote Sp option allows you to select either the Use% radio button (for restricting the setpoint changes to be in percentage) or Use Pv units radio button (for setpoint changes to be in Pv units). • Use%. If the Remote Sp is set to Use%, then the controller reads in a value in percentage from a remote source, and using the Pv range calculates the new setpoint. • Use Pv units. If the Remote Sp is set to Use Pv units, then the controller reads in a value from a remote source and sets a new setpoint. The remote source’s setpoint must have the same units as the controller Pv. SetPoint Options Group If the Track PV radio button is selected, then there is automatic setpoint tracking in manual mode, that sets the value of the setpoint equal to the value of the Pv prior to the controller being placed in the manual mode. This means that upon switching from manual to automatic mode the values of the setpoint and Pv were equal and, therefore, there was an automatic bumpless transfer. Also you have the option not to track the pv, by clicking the No Tracking radio button, when the controller is placed in manual mode. However, when the controller is switched into the automatic mode from manual, there is an internal resetting of the controller errors to ensure that there is an instantaneous bumpless transfer prior to the controller recognizing a setpoint that is different from the Pv. An example, it is desired to control the flowrate in a stream with a valve. A MPC controller is used to adjust the valve opening to achieve the desired flowrate, that is set to range between 0.2820 m3/h and 1.75 m3/h. A spreadsheet is used as a remote source for the controller setpoint. A setpoint change to 1 m3/h from the current PV value of 0.5 m3/h is made. The spreadsheet internally converts the new setpoint as m3/s (1/3600 = 0.00028 m3/s) and passes it to the controller, which reads the value and converts it back into m3/h (1 m3/h). The controller uses this value as the new setpoint. If the units are not specified, then the spreadsheet passes it as 1 m3/s, which is the base unit in HYSYS, and the controller converts it into 3600 m3/ h and passes it on to the SP field as the new setpoint. Since the 5-145 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-146 Control Ops ww ThPV maximum value cannot exceed 1.75m3/h, the controller uses the maximum value (1.75 m3/h) as the new setpoint. Alarms Page The Alarms page allows you to set alarm limits on all exogenous inputs to and outputs from the controller. The page contains two groups: • Alarm Levels • Alarms Alarm Levels Group The Alarm Level group allows you to set, and configure the alarm points for a selected signal type. There are four alarm points that could be configured: • LowLow • Low • High • HighHigh The alarm points should be specified in the descending order from HighHigh to LowLow points. You cannot specify the value of the Low and LowLow alarm points to be higher than the signal Figure 5.905-146 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-147 ww Thvalue. Similarly, the High and HighHigh alarm points cannot be specified a value lower than the signal value. Also, no two alarm points can be specified a similar value. In addition, you can specify a deadband for a given set of alarms. This can be helpful in situations where the signal is “noisy” to avoid constant triggering of the alarm. If a deadband is specified, you have to specify the alarm points so that their difference is greater than the deadband. At present, the range for the allowable deadband is as follows: of the signal range. Alarms Group The Alarms group displays the recently violated alarm for the following signals: An example, it is desired to control the flowrate through a valve within the operating limits. These limits can be monitored using the Alarms feature in MPC Controller. Multiple alarms can be set to alert you about increase or decrease in the flowrate. For the purpose of this example, you are specifying low and high alarm limits for the process variable signal. Assuming that the normal flowrate passing through the valve is set at 1.2 m3/h, the low alarm should get activated when the flowrate falls below 0.7 m3/ h. Similarly, when the flowrate increases to 1.5 m3/h the high alarm should get triggered. To set the low alarm, first make sure that the Pv Signal is selected in the Signal drop-down list. Specify a value of 0.7 m3/ h in the cell beside the Low alarm level. Follow the same procedure to specify a High alarm limit at 1.5 m3/h. If you want The above limits are set internally and are not available for adjustment by the user. Signal Description PV Process Variable OP Output SP Setpoint 0.0% deadband 1.5%≤ ≤5-147 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-148 Control Ops ww Thto re-enter the alarms, click the Reset Alarm button to erase all the previously specified alarms. Signal Processing Page The Signal Processing page allows you to add filters to any signal associated with the MPC controller, as well as test the robustness of any tuning on the controller. This page is made up of two groups: • Signal Filters • Noise Parameters Both of these groups allow you to filter, and test the robustness of the following tuning parameters: • Pv • Op • Sp • Rs To apply the filter select the checkbox corresponding to the signal you want to filter. Once active you can specify the filter time. As you increase the filter time you are filtering out frequency information from the signal. For example the signal is noisy, there is a smoothing effect noticed on the plot of the PV. Figure 5.915-148 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-149 ww ThNotice that it is possible to add a filter that makes the controller unstable. In such cases the controller needs to be returned. Adding a filter has the same effect as changing the process the controller is trying to control. Activating a Noise Parameter is done the same way as adding a filter. However, instead of specifying a filter time you are specifying a variance. Notice that if a high variance on the PV signal is chosen the controller may become unstable. As you increase the noise level for a given signal you observe a some what random variation of the signal. MPC Setup Tab The MPC controller has a number of setup options available. These options are available on the Basic and Advanced pages of the Setup tab. In order to change any of the default values specified on these pages it is necessary to enable the MPC modifications checkbox. Whatever the option chosen, it is important to establish a sampling period (control interval) first. Specifically, the sampling period must be chosen to be consistent with the sampling theorem (see Shannon's Sampling Theorem). As such, it should be about 1/5 to 1/10 of the smallest time-constants. If the process is heavily dominated by process deadtime then the sampling period should be based on the deadtime. In situations where the process models are a mix of fast and slow process dynamics care should be taken in selecting the sampling period. A carefully designed MPC controller is an effective and efficient controller.5-149 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-150 Control Ops ww ThBasic Page The Basic page divides the setup settings into MPC Control Setup and MPC Process Model Type groups. MPC Control Setup Group In the MPC Control Setup group you are required to specify the following: • Num of Inputs. Allows you to specify the number of process input. Up to a maximum of 12 process inputs can be specified. The default value is 1. • Num of Outputs. Allows you to specify the number of process output. Up to a maximum of 12 process inputs can be specified. The default value is 1. • Control Interval. Allows you to specify the control or sampling interval. The default value is 30 seconds. Figure 5.92 Anytime one of the MPC setting is changed, a new MPC object has to be created internally-this is automatically achieved by clicking on the Create MPC button.5-150 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-151 ww ThMPC Process Model Type Group You have the option to specify the model to be either Step response data or a First order model. If the Step response data radio button is selected, then a text file can be used to input the process model. The input file must follow a specific format in terms of inputs and outputs, as well as columns of data. The following is a description of the ASCII text file required for the input: The step response data is typically obtained either directly from plant data, or they are deducted from other so-called parametric model forms such as Discrete State-Space and Discrete Transfer Function Models. Figure 5.93 Number of inputs Number of outputs Number of columns Step response length Data5-151 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-152 Control Ops ww ThAdvanced Page The Advanced page divides the setup settings into MPC Control Setup, MPC Process Model Type, and MPC Control Type groups. MPC Control Setup Group In the MPC Control Setup group you are required to specify the following: Figure 5.94 Anytime one of the MPC setting is changed, a new MPC object has to be created internally-this is automatically achieved by clicking on the Create MPC button. Field Description Num of Inputs The number of process input. Up to a maximum of 12 process inputs can be specified. The default value is 1. Num of Outputs The number of process output. Up to a maximum of 12 process outputs can be specified. The default value is 1. Control interval The control or sampling interval. The default value is 30 seconds. Step Resp. length The number of sampling intervals that is necessary to reach steady state when an input step is applied to the process model. The range of acceptable values are from 15 to 100. The default value is 50.5-152 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-153 ww ThStep Response Length This value represents the number of sampling intervals that is necessary to reach steady state when an input step is applied to the process model. You should consider all of the process models and the sampling interval when selecting step response length. At present, the maximum step response is limited to 100 sampling intervals. Also, the fact that you are specifying the process models in terms of step response means that you are only considering stable processes in this MPC design. Prediction Horizon and Control Horizon The prediction horizon represents how far into the future the controller makes its predictions, based on the specified process model. The prediction horizon is limited to the length of the step response, and should be greater than the minimum process model delay. A longer prediction horizon means that the controller looks further into the future when solving for the controller outputs. This may be better if the process model is accurate. In general, you want to take full advantage of the process model by using longer predictions. The control horizon is the number of control moves into the future the controller considers when making its predictions. In general, the larger the number of moves, the more aggressive Prediction Horizon Allows you to specify how far into the future the predictions are made when calculating the controller output. The Prediction Horizon should be less than or equal to the Step Response Length. The default value is 25. Control horizon The number of control moves into the future that are made to achieve the final setpoint. A small control horizon generally means a less aggressive controller. The Control Horizon should be less than or equal to the Prediction Horizon. The default value is 2. Reference trajectory The time constant of a first order filter that operates on the true setpoint. A small reference trajectory lets the controller see a pure step as the setpoint is changed. The default value is 1. Gamma_U/ Gamma_Y The positive-definite weighting functions, which are associated with the optimization problem that is solved to produce the controller output every control interval. The value of Gamma_U and Gamma_Y should be between 0 and 1. The default value is 1. Field Description5-153 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-154 Control Ops ww Ththe controller is. As a rule of thumb a control horizon of less than 3 is used quite often. Sampling Interval and reference trajectory Once you have determined the control interval, other parameters like reference trajectory can be chosen. This value affects the reference setpoint of the predictions used by the MPC problem when solving for the control outputs. Essentially, the reference trajectory represents the time constant of a first order filter that operates on the true setpoint. Hence, a very small value for the reference trajectory implies that the setpoint used in the MPC calculations are close to the actual setpoint. The minimum value for the reference trajectory that can be selected is 1second. One of the problems that could arise in setting this value “too large” is that the final setpoint reference value, which is used in the predictions, would not be seen by the control algorithm in a given iteration. Therefore, it is important that the reference trajectory value be chosen such that the time constant is smaller than the smallest time constant of the user specified process model set. At present, there is a limit placed on the reference trajectory that is based on the sampling interval and the maximum step-response. However, you should use the process model set as a guide when selecting this value. In the present version the limits for the reference trajectory is as follows: MPC Process Model Type Group You have the option to specify the model to be either Step response data or First order model. If the Step response data is selected, then a text file can be used to input the process model. The input file must follow a specific format in terms of inputs and outputs, as well as columns of data, as shown in Figure 5.94. (5.25)1 Reference Trajectory 15 Sampling Interval×≤ ≤5-154 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-155 ww ThMPC Control Type Group This group allows you to select the MPC Control Algorithm that is used by the controller. At Present, the only option available for selection is the MPC Unconstrainted (No Int). This algorithm does not consider constraints on either controlled and manipulated variables. Process Models Tab The Process Models tab allows you to either view the step response data, or specify the first order model parameters. Basic Page Step Response Data If the Step response data radio button is selected on the MPC Setup tab, the Process Model tab displays the Model Step Response matrix. Figure 5.955-155 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-156 Control Ops ww ThDepending on the number of inputs (i) and outputs (o) the system’s dynamics matrix should be an matrix. The number of process models is equal to the number of outputs or controlled variables. If the Step response data is selected, then the First order model parameters fields are greyed out. First Order Model If the First order model is selected on the MPC Setup tab, the Process Model table appears. You can specify the first order model parameters for each of the process models, as follows: 1. Select the input and output variable number in the Input # and Output # selection field by clicking the up or down arrow button , or by typing the appropriate number in the field. 2. Depending upon the input and output variable selected, the relevant process model appears. 3. Then specify the process gain (Kp), process time constant (Tp) and delay for the selected process model in the available matrix. 4. Repeat step# 1-2 for the remaining process models. 5. Then click the Update Step Response button to calculate the step response data for the process models. You cannot modify the model step response data on the Process Model tab. i o×5-156 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-157 ww ThAdvanced Page The Advanced page lists all of the Process Models, and their associated tuning parameters in table. Stripchart Tab The Stripchart tab allows you to select and create default strip charts containing various variable associated to the operation. User Variables Tab The User Variables tab enables you to create and implement your own user variables for the current operation. Figure 5.96 Refer to Section 1.3.7 - Stripchart Page/Tab for more information. For more information refer to Section 1.3.8 - User Variables Page/ Tab.5-157 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-158 Control Ops ww Th5.4.6 DMCplus Controller The DMCplus Controller engine runs in Aspen DMCplus Online. HYSYS communicates to DMCplus using the DMCplus API. You are required to have the following licenses to run DMCplus in HYSYS: • DMCplus Link • DMCplus Online • Cim-IO Kernel • ACO Base The figure below shows the HYSYS and DMCplus connection. HYSYS works like a Real Plant. The DMCplus Desktop allows you to configure the models. Each DMCplus Controller requires a Model File (MDL) and a Controller Configuration File (CCF) to operate properly with the Aspen DMCplus. • The MDL file determines the size of the control problem and all the dynamic relationships between each independent and dependent variables. Figure 5.97 You must install DMCplus Online and DMCplus Desktop for the DMCplus Controller to operate properly. • DMCplus Online is required to run the DMCplus Controller. • DMCplus Desktop allows you to configure the model used by the DMCplus Controller. Refer to the Aspen Manufacturing Suite Installation Guide for information on installing DMCplus Online and DMCplus Desktop. For information on adding the DMCplus Controller, refer to Section 5.4.1 - Adding Control Operations.5-158 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-159 ww Th• The CCF file determines where the input and output parameters for the controller will reside, which optional capabilities will be used, and the values assigned to all of its parameters such as limits, switches, and tuning. HYSYS can generate the MDL file automatically or record the independent and dependent variable in the collection files (CLC), which contains model testing data. The data in the CLC files are used by the DMCplus Model to create the MDL file. The MDL file is then used by the Aspen DMCplus Build to create a CCF file. You can add the DMCplus Controller to an existing HYSYS simulation case or to a new HYSYS simulation case that you have created. The DMCplus property view contains the following tabs: • Connections • Model Test • Operation • Stripchart • User Variables Figure 5.98 If the DMCplus Controller is not loaded, it appears in yellow in the HYSYS flowsheet. The status bar on the DMCplus Controller property view will also appear in yellow and indicate that the DMCplus has not been loaded.5-159 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-160 Control Ops ww ThThe DMCplus Controller property view also contains an Enable DMCplus checkbox at the bottom right corner. This checkbox allows you to enable or disable the DMCplus Controller. When the Enable DMCplus checkbox is disabled, the model testing features can be enabled in the Model Test tab. Connections Tab The Connections tab allows you to define and edit the Controlled, Manipulated and Feed Forward variables for the plant model. You can specify the name of the DMCplus Controller in the Controller Name field. You have to select the Enable DMCplus Modifications checkbox to add and edit the Controlled, Manipulated, and Feed Forward variables. Figure 5.99 When editing the Controlled and Manipulated variables in the DMCplus Model, ensure that the variable order is the same as in HYSYS. 5-160 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-161 ww ThControlled Variable (CV) You must specify a controlled variable for the DMCplus Controller. The controlled variables are the dependent variables that will be controlled by the DMCplus controller. The CV table contains the stream or operation that owns the variable you want to control. The stream or operation is specified using the Select Input property view, which appears when you click the Add CV button or Insert CV button. • The Add CV button adds the stream or operation after the last defined stream or operation in the table. • The Insert CV button adds the stream or operation before the currently selected stream or operation in the table. You can select the appropriate object and variable simultaneously using the Select Input property view. Figure 5.100 Figure 5.101 Refer to Section 1.3.9 - Variable Navigator Property View for information on the Select Input property view.5-161 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-162 Control Ops ww ThManipulated Variable (MV) You must specify a manipulated variable for the DMCplus Controller. The manipulated variables are the independent variables that will be manipulated by the DMCplus controller. The MV table contains the stream or operation which is controlled by the controller operation. • The Add MV button adds the stream or operation after the last defined stream or operation in the table. • The Insert MV button adds the stream or operation before the currently selected stream or operation in the table. The stream or operation is specified using the Select Object property view, which appears when you click the Add MV button or Insert MV button. When you add a stream to the MV table the Control Valve button is enabled. Figure 5.102 Figure 5.103 Refer to Section 5.4.7 - Control Valve for more information.5-162 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-163 ww ThFeed Forward (FF) You can add the Feed Forward variables if needed. The variable takes into account measured disturbances which you can view on the Feed Forward page of the Operation tab. You can add the Feed Forward variables using the Select Input property view similar to when you are adding a controlled variable. • The Add FF button adds the stream or operation after the last defined stream or operation in the table. • The Insert FF button adds the stream or operation before the currently selected stream or operation in the table. The Feed Forward variables are used as independent variables in the DMCplus Model, and they cannot be manipulated by the DMCplus Controller. Figure 5.1045-163 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-164 Control Ops ww ThModel Test Tab The Model Test tab allows you to set up the DMCplus Controller for model testing. The Model Test page is the only page available on this tab. The following table lists and describes the objects available in the Model Test tab: Figure 5.105 Object Description Model Test Setting group Test Signal Type cell Enables you to select the signal type for the DMCplus model test. There are two types of signal to choose from: • PRBS is simple to use for model identification. • STEP is more recognized in practical process applications. Control/Sampling Time Interval cell Enables you to specify the amount of time between recorded data points during the testing phase. TTSS cell Enables you to specify the total time period available for the model testing. The value should at least be larger than the setting time of the system.5-164 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-165 ww ThAuto Test checkbox Enables you to toggle between activating or deactivating the Auto Test option. This option performs test for each of the selected Manipulated and Feed Forward variables one by one. The test results are used to generate an MDL file (which contains the DMCplus controller model). If this checkbox is clear, you need to manually save the testing data to CLC files. Conf. Ramp button Enables you to access the Configure Ramp Response property view. The Configure Ramp Response property view enables you to select the ramp type for each CV tag using the drop-down list available under the Ramp Type column. There are three types of ramp type to choose from: • non-ramp • ramp • pseudo ramp The Conf. Ramp button is only available if you selected the Auto Test option. Auto test file root name field Enables you to specify the location and name of the testing data files containing the auto test results and the date and time when the test was performed. This field is only available if the Auto Test checkbox is selected. Epsilon icon Enables you to access the File Selection for Saving Test results property view and select the location to save the test result files. This icon is only available if the Auto Test checkbox is selected. Monitor table Time left cell Displays the amount of time left in the model testing. Current Interval cell Displays the current interval value during the model testing calculation. Object Description5-165 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-166 Control Ops ww ThTotal Intervals cell Displays the total number of intervals required to complete the model testing. Ready cell Displays an icon to indicate whether the selected model is ready for testing: • Red cross indicates the model is not ready. • Green checkmark indicates the model is ready for testing. Enable Test cell Enables you to activate the model testing when the Start Test button is clicked. Model Test Help icon Enables you to access the help property view that displays the steps required to develop the DMCplus controller. Start Test button Enables you to first reset the test and then start the model testing. Continue Test button Enables you to continues the last test if it has not been finished. Stop Test button Enables you to stop the model testing before the test is complete Select tag to apply the testing signal table No. column Displays an integer number for each MV and FF variables in the DMCplus controller. MV & FF Tag column Displays the name of the MV and FF variables in the DMCplus controller. If a Feed Forward variable (FF) is a dependent (or calculated) variable, HYSYS cannot perform the test at the default/current setting. Selected column Contains checkboxes that enable you to toggle between selecting or ignoring the variables for the test. By default, all the Manipulated variables (MV) and Feed Forward variables (FF) are selected to apply the test signal. Tested column Display the status of the variable, whether it has been tested or not, during the testing process. Step Up column Contains checkboxes that enable you to toggle between step up testing or step down testing for each variable. By default, the checkboxes are set to step up. Amplitude column Enables you to specify the percentage value of testing signal amplitude for each variable. By default, the signal amplitude is set at 1.00%. Reset Test button Enables you to reset the model testing back to the beginning. Object Description5-166 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-167 ww ThPerforming DMCplus Model Testing After selecting the controlled, manipulated, and feed forward variables, data needs to be generated from the plant model to develop the controller model. Follow the steps below to develop the controller model: 1. From the Model Testing Setting group, select the test setting parameters. • In the Test Signal Type drop-down list, select STEP or PRBS. • In the Control/Sampling Time Interval cell, specify the time used to determine how often the data points are recorded during the testing phase. • In the TTSS cell, specify the total time period during which to apply the testing. • In the Auto Test cell, use the checkbox to toggle between activating or deactivating the Auto Test option. • Click the Conf. Ramp button to access the Configure Ramp Response property view. In the Configure Ramp Response property view, select the ramp characteristic/ option for each CV data using the drop-down list under the Ramp Type column. • In the Auto test file root name field, specify the location and name for the generated testing data files. This field is only available if the Auto Test checkbox is selected. 2. The Select tag to apply the testing signal table contains several options to configure the variable to be tested. Save Test Results button Enables you to save the test data results in a *.clc file or a set of *.rec files. Load DMC Controller button Enables you to load and run the configured DMCplus controller model in the HYSYS simulation case. This button is disabled if you do not have the configuration (.ccf) and model (.mdl) files in the correct directory. It is recommended that the default setting in the Select tag to apply the testing signal table be modified by advance users for special case. Object Description5-167 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-168 Control Ops ww Th3. In the Monitor table, select the Enable Test checkbox, to automatically activate the model testing when the Start Test button is clicked. 4. Click the Start Test button to start the testing. When the Time left field displays zero, the testing is finished. • If you had selected the Auto Test option, you can skip steps #5 to #6 because HYSYS will automatically generate an MDL file. • If you did not select the Auto Test option, you have to manually save the test results in a file. 5. Click the Save Test Result button, and save the testing results to a *.clc file or a set of *.rec files. The CLC or REC file(s) can be processed by the Aspen DMCplus Model to generate a MDL file. Before you start the testing, ensure that all the related slave PID Controllers are set to the remote mode. Figure 5.1065-168 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-169 ww Th6. Start the Aspen Model application, load the saved data and build the DMCplus model (*.mdl). In the DMCplus Model you will import the Collect file (*.clc) to vectors by saving the project first and then adding the CLC file. If HYSYS has already generated the MDL file, you can still import the file into the DMCplus Model to review the generated model. The MDL file determines the size of the control problem and all the dynamic relationships between each independent and dependent variables. Figure 5.107 When adding the independent (MV) and dependent (CV) variables to a case, ensure that the order you are adding the variables is the same as on the Connections tab in HYSYS. Refer to the DMCplus Desktop manual for details.5-169 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-170 Control Ops ww Th7. Start the Aspen Build application and build the DMCplus configuration file (*.ccf). The CCF file determines where the input and output parameters for the controller will reside, which optional capabilities will be used, and the values assigned to all of its parameters such as limits, switches, and tuning. 8. Open the app folder in the DMCplus Online installation directory. 9. Create a folder with the controller name (for example DMC_100) and copy the *.mdl and *.ccf files into the folder. 10.Return to HYSYS program. 11.Click the Load DMCplus Controller button. You should now be able to run the simulation using the newly created DMCplus Controller. You can set the low and high variable limits for MVs and CVs (similar to setpoint range). Figure 5.108 The DMCplus Controller requires that the DMCplus Online and DMCplus Desktop programs are installed. Refer to the Aspen Manufacturing Suite Installation Guide for information on installing DMCplus Online and DMCplus Desktop. Refer to the DMCplus Desktop manual for details. For information on setting the low and high variable limits, refer to the Operation Page section.5-170 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-171 ww ThOperation Tab The Operation Tab contains the following pages: • Operation • FF Variable Operation Page The Operation page allows you to set the controller mode and the low/high limit parameters. DMCplus uses these low/high parameters to optimize the controlled variable (CV) and manipulated variable (MV) setpoints (steady state target) based on its tuning parameters. All DMCplus Controllers created can be viewed using the DMCplus GUI. The DMCplus GUI provides more functionality on using the DMCplus Controller. Figure 5.1095-171 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-172 Control Ops ww ThThe CV SS target is similar to the MPC Controller setpoint except: • In MPC controller, you specify the CV SS target value. • In DMCplus controller, you specify the lowest and highest setpoint values, and DMCplus calculates the CV SS target value based on the provided range. The Update CCF File button enables you to export any update configuration results from the Operation page into the *.ccf file. The Set Default Low/High Parameters button enables you to populate the CV and MV parameters with default values (refer to the table below): The CV and MV SS targets are fixed, if the low/high limit values are the same. Mode The DMCplus Controller operates in any of the following modes: • Off. The DMCplus Controller does not manipulate the control valve, although the appropriate information is still tracked. • Manual. Manipulates the DMCplus Controller output manually. In the Manual mode you can enter a value for the Manipulated Variable (MV). • Automatic. The DMCplus Controller reacts to fluctuations in the Controlled Variable (CV) and manipulates the Manipulated Variable (MV) according to the DMCplus algorithm. For CV: Low Limit = current value High Limit = current value For MV: Low Limit = 0 High Limit = highest value limited by the variable span For more information on the MPC Controller, refer to Section 5.4.5 - MPC Controller.5-172 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-173 ww ThThe mode of the controller may also be set on the Face Plate. FF Variable Page The Feed Forward Variable page allows you to view the controller measured disturbance. Stripchart Tab The Stripchart tab allows you to select and create default strip charts containing various variable associated to the operation. On the Face Plate, you can also view the current value of the CV and MV. You cannot change the low/high limit using the Face Plate. The Feed Forward Variable page will only show the Feed Forward value if the Feed Forward variable has been added on the Connections tab. Figure 5.110 Refer to Section 5.13.2 - Controller Face Plate for more information. Refer to the section on the Feed Forward (FF) for more information. Refer to Section 1.3.7 - Stripchart Page/Tab for more information.5-173 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-174 Control Ops ww ThUser Variables Tab The User Variables tab enables you to create and implement your own user variables for the current operation. 5.4.7 Control Valve The information shown on the Control Valve property view is specific to the associated valve. For instance, the information for a Vapour Valve is different than that for an Energy Stream. To access the Control Valve property view, click the Control Valve button located at the bottom right corner of the controller operation property view. FCV for a Liquid/Vapour Product Stream from a Vessel The FCV property view for a material stream consists of two groups: • Valve Parameters • Valve Sizing The Control Valve button appears if the OP is a stream. Figure 5.111 For more information refer to Section 1.3.8 - User Variables Page/ Tab.5-174 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-175 ww ThThe Valve Parameters group contains flowrate information about the stream with which the Control Valve is associated. The Valve Sizing group is usually part of the property view that requires specification. This group contains three fields, which are described in the table below: The Minimum and Maximum flow values define the size of the valve. To simulate a leaky valve, specify a Minimum flow greater than zero. The actual output flow through the Control Valve is calculated using the OP signal (% valve opening): For example, if the Controller OP is 25%, the Control Valve is 25% open, and is passing a flow corresponding to 25% of its operating span. In the case of a liquid valve, if the Minimum and Maximum flow values are 0 and 150 kgmole/h, respectively, the actual flow through the valve is 25% of the range, or 37.5 kgmole/h. FCV for Energy Stream The FCV property view that appears is dependent on the type of duty stream selected. There are two types of duty streams: • Direct Q duty consists of a simple power value (in other words, BTU). • Utility Fluid takes the duty from a utility fluid (in other words, steam) with known properties. Field Description Flow Type The type of flow you want to specify: • molar flow • mass flow • liquid volume flow • actual volume flow Min. Flow The Minimum flow through the control valve. Max. Flow The Maximum flow through the valve. (5.26)Flow OP %( ) 100 ----------------- Maximum Minimum–( ) Minimum+=5-175 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-176 Control Ops ww ThThe type of Duty Source specified can be changed at any time by clicking the appropriate radio button in the Duty Source group. Direct Q Duty Source This is the Flow Control Valve (FCV) view, when the Duty Source is set to Direct Q in the Duty Source group. The Attached Stream and Controller appear in the upper left corner of the property view in the Control Attachments group. The specifications required by the property view are all entered into the Direct Q group. In this group, Setpoint (SP) appears, and you may specify the minimum (Min. Available) and maximum (Max. Available) cooling or heating available. Figure 5.1125-176 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-177 ww ThFrom Utility Fluid Duty Source As with the Direct Q Duty Source, the attached stream, and controller appear in the upper left corner of the property view. There are several Utility Fluid Parameters, which can be specified in the Utility Properties group: Available to Controller checkbox. When you make the controller connections, and move to the Control Valve property view (by clicking the Control Valve button on the PID Controller property view), the Available to Controller checkbox is Figure 5.113 The application of the Utility Fluid information is dependent on the associated operation. Parameter Description UA The product of the local overall heat-transfer coefficient and heat-transfer surface area. Holdup The total amount of Utility Fluid at any time. The default is 100 kgmole. Flow The flowrate of the Utility Fluid. Min and Max Flow The minimum and maximum flowrates available for the Utility Fluid. Heat Capacity The heat capacity of the Utility Fluid. Inlet and Outlet Temp The inlet and outlet temperatures of the Utility Fluid. T Approach The operation outlet temperature minus the outlet temperature of the Utility Fluid. 5-177 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-178 Control Ops ww Thautomatically selected. HYSYS assumes that because you installed a new controller on the valve, you probably want to make it available to the Controller. 5.4.8 Control OP Port To access the Control OP Port property view, click the Control OP Port button at the bottom right corner of the control operation property view. The following table lists and describes the common options in the Control OP Port property view: The Control OP Port button appears when the OP is not a stream and a range of specified values is required. Figure 5.114 Object Description Attached Object cell Displays the name of the output target object attached to the controller. Attached Controller cell Displays the name of the controller attached to the output target object. Current Value cell Displays the current value of the output target object variable. Minimum Value cell Enables you to specify the minimum value for the output target object variable. Maximum Value cell Enables you to specify the maximum value for the output target object variable.5-178 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-179 ww Th5.5 Digital Point The Digital Point is an On/Off Controller. You specify the Process Variable (PV) you want to monitor, and the output (OP) stream which you are controlling. When the PV reaches a specified threshold value, the Digital Point either turns the OP On or Off, depending on how you have set up the Digital Point. 5.5.1 Digital Point Property View There are two ways that you can add a Digital Point to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Logicals radio button. 3. From the list of available unit operations, select Digital Pt. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the Digital Control Point icon. The PV is optional; if you do not attach a Process Variable Source, the Digital Point operates in Manual mode. Digital Control Point icon5-179 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-180 Digital Point ww ThThe Digital Point property view appears. 5.5.2 Connections Tab The Process Variable Source and Output Target are both optional connections. No error is shown when these are not connected nor does an error appear in the Status List Window. Figure 5.115 Figure 5.116 Click the Control Valve button to view the Control Valve property view. Click the Face Plate button to view the Controller Face Plate. The Process Variable object (stream or operation) that owns the variable you want to control. The Process Variable you want to control. The Output object is the stream, which is controlled by the Digital Point.5-180 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-181 ww ThThe optional connections feature allows the controller to be in Manual mode, and have its OPState imported into a Spreadsheet and used in further calculations in the model. This configuration can only be used for Manual mode. To run the controller in Automatic mode, you require a Process Variable Source input. With only the input connected, the Digital Point acts as a digital input indicator. With both the input and output specified the Digital Point can be used to determine its state from its PV and then take a discrete action. To specify the controller input, use the Select PV button to access the Variable Navigator property view, which allows you to simultaneously target the PV Object and Variable. Similarly, use the Select OP button to choose the Output Target. 5.5.3 Parameters Tab The Parameters tab provides three different modes of operation: • Off • Manual • Auto For each of these modes the Parameters tab is made up of a number of groups: Output, Manual/Auto Operational Parameters, and Faceplate PV Configuration. Off Mode When Off mode is selected, you cannot adjust the OP State. Notice that if you turn the controller Off while running the simulation, it retains the current OP State (Off or On). Thus, turning the Controller off is not necessarily the same as leaving the Controller out of the simulation. The flow of the OP Output is manipulated by the Digital Point Controller. Refer to Section 1.3.9 - Variable Navigator Property View for information.5-181 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-182 Digital Point ww ThOnly the Output group, displaying the current OP State, is visible when in the Off mode. Manual Mode When Manual mode is selected you can adjust the OP State from the Faceplate or this tab. Two groups are visible when in this mode: Output and Manual Operation Parameters. The Output group allows you to toggle the OP state on and off. The Operational Parameters group allows you to select one of the three options described in the table below. Figure 5.117 Figure 5.118 Option Description Latch Holds the current OP State to what is specified in the Output group. Pulse On Allows the OP State to Pulse On for a specified period and fall back to the Off state. Pulse Off Allows the OP State to Pulse Off for a specified period and fall back to the On state.5-182 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-183 ww ThAuto Mode When Auto mode is selected, HYSYS automatically operates the Digital Point, setting the OP State Off or On when required, using the information you provided for the Threshold and OP Status. Three groups are visible when in this mode: Output, Auto Operational Parameters, and Faceplate PV Configuration. Since HYSYS is automatically adjusting the controller, the Output group simply displays the OP State. Like Manual mode, the Auto Operation Parameters group allows you to select one of the three options: • Latch • Pulse On • Pulse Off Figure 5.119 Figure 5.120 Allows you to specify the duration of the pulse.5-183 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-184 Digital Point ww ThWhen Latch is selected the following parameters appear. For both the Pulse On and Pulse Off options the parameters are the same as the Latch option. However the pulse options both require you to specify a Pulse Duration. The Face Plate PV Configuration group allows you to specify the minimum and maximum PV range. This is the range shown on the controllers Face Plate. Threshold and Dead Band for Latch For the Latch option, the OP (output) switches states (on or off) when the PV (Process Variable) value reaches the set point value. The set point value is accompanied with an adjustable differential gap or dead band value, this value allows small deviations to occur in the PV value without triggering changes to the OP state. Parameter Description PV The actual value of the PV (Process Variable). Threshold The value of the PV which determines when the controller switches the OP on or off. Higher Deadband Allows you to specify the upper deviation of the threshold value. Lower Deadband Allows you to specify the lower deviation of the threshold value. OP On/Off when Allows you to set the condition when the OP state is on or off. Figure 5.121 For more information regarding how Digital Point logical operation determines when to turn the OP state on or off, refer to Threshold and Dead Band for Latch section. For more information regarding how Digital Point logical operation determines state of the Pulse (on or off), refer to Threshold and Dead Band for Pulse section.5-184 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-185 ww ThThe following is an example of how the Latch option operates. Assume you have a Digital Point operation with the following parameters: The following situations illustrates when the OP is turned on or off. • Initial State. If PV value starts at 70 and OP is off, the OP stays off until the PV value rises above or to equal 145, than OP is turned on. • Intermediate State. If PV value rises and falls above value 80 and OP state is already on, then OP remains on. • Intermediate State. If PV value falls below or equal value 80, OP is turned off. The above situation is the same for Latch option with OP is on when PV <= Threshold, with the reverse effect. In other words, Parameter Value Threshold 100 Higher dead band 45 Lower dead band 20 OP is on when PV >= Threshold Figure 5.122 • Red line indicates the path of the OP vs. time. • Blue line indicates the path of the PV vs. time. If PV value starts at 150 and OP state is off, then OP remains off until the PV value falls below 80 and rises above 145, after PV reaches or rises above 145 the OP state is turned on. Dead band OP PV Time5-185 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-186 Digital Point ww ThOP is turned on when PV value passes through the lower dead band value, and OP is turned off when PV value passes through the higher dead band value. Threshold and Dead Band for Pulse For the Pulse option, the OP (output) remains in a state (on or off) until the PV (Process Variable) value reaches the set point value, then OP switches state briefly and returns back to its default state (like a pulse). The set point value is accompanied with an adjustable differential gap or dead band value, this value allows small deviations to occur in the PV value without triggering the OP state pulse. The following is an example of how the Pulse option operates. Assume you have a Digital Point operation with the following parameters: Parameter Value Pulse Off. The OP default state is off. Threshold 100 Higher dead band 45 Lower dead band 20 Pulse ON/OFF when PV >= Threshold Pulse Duration 2 seconds5-186 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-187 ww ThThe following situations illustrates when the OP is turned on or off. • If PV value starts at 70, the OP is off until the PV value rises to equal 145, than OP is on for 2 seconds. • After OP state has pulsed on once, OP remains off if PV value rises and falls above the value 80. 5.5.4 Stripchart Tab The Stripchart tab allows you to select and create default strip charts containing various variable associated to the operation. 5.5.5 User Variables Tab The User Variables tab enables you to create and implement your own user variables for the current operation. Figure 5.123 • Red line indicates the path of the OP vs. time. • Blue line indicates the path of the PV vs. time. If PV value starts at 150, OP is off until the PV value falls below 80 and rises above 145, after PV reaches 145 the OP state is on for 2 seconds. OP PV Time OP turned on for 2 seconds PV value falls below lower dead band. Dead band Refer to Section 1.3.7 - Stripchart Page/Tab for more information. For more information refer to Section 1.3.8 - User Variables Page/ Tab.5-187 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-188 Digital Point ww Th5.5.6 Alarm Levels Tab The Alarms tab allows you to set alarm limits for the controller. The Alarm Level group allows you to set and configure the alarm points for a selected signal type. There are four alarm points that can be configured: • LowLow • Low • High • HighHigh The alarm points should be specified in the descending order from HighHigh to LowLow points. You cannot specify the value of the Low and LowLow alarm points to be higher than the signal value. Similarly, the High and HighHigh alarm points cannot be specified a value lower than the signal value. Also, no two alarm points can have a similar values. In addition, the user can specify a deadband for a given set of alarms. This can be helpful in situations where the signal is “noisy” to avoid constant triggering of the alarm. If a deadband is specified, you have to specify the alarm points so that their difference is greater than the deadband. At present the range for the allowable deadband is as follows: of the signal range. The Alarm Status displays the recently violated alarm for each alarm point. Figure 5.124 The above limits are set internally and are not available for adjustment by the user! 0.0% deadband 1.5%≤ ≤5-188 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-189 ww Th5.6 Parametric Unit Operation The Parametric Unit operation allows selected unit operations, streams, and variables to be solved using a Parametric model. The main function of the Parametric model is to approximate an existing HYSYS model. To build the Parametric model, the Parametric Utility tool is required. The Parametric utility integrates Neural Network (NN) technology into its framework. A data file with the appropriate data can be used in place of the Parametric Utility. Using a Parametric model with neural network capability to approximate a HYSYS model significantly improves the robustness of the model, reduces its calculation time, and improves the overall on-line performance. The accuracy of the model depends upon the data available and type of model being approximated. In the flowsheet, the parametric unit operation essentially “pulls out” a collection of HYSYS unit operations and replaces them. Therefore, this unit operation can be thought of as a “black box” with inputs and outputs. When the flowsheet is solved, the Parametric model is used in place of the individual HYSYS unit operation models. For more information on this utility, refer to Section 14.14 - Parametric Utility.5-189 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-190 Parametric Unit Operation ww Th5.6.1 Parametric Unit Operation Property View To add a Parametric Unit Operation to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Logicals radio button. 3. From the list of available unit operations, select Parametric Unit Operation. 4. Click the Add button. The Parametric Unit Operation property view appears. The property view has four tabs: • Design • Training • Worksheet • Validation 5.6.2 Design Tab The Design tab contains the following pages: • Connections • Setup • Notes Connections Page The Connections page allows the parametric unit operation to be connected with the information required for the Parametric model. This information can be found in either a Parametric Utility or a data file. This page always contains a Name field and Input Data group. The rest of the page is different depending on the selected Input Data type. The Name field allows you to define a unique name for the unit 5-190 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-191 ww Thoperation. The Input Data group allows you to define where the input data to the Parametric model is to be found. The rest of the property view is altered depending on the radio button selected. The options available are: • Use Utility Data • Inputs from a Data File Each of the radio buttons are described in the following sections. Use Utility Data Radio Button When the Use utility data radio button is selected, one additional group (Parametric/LP Utility Selection) and two additional buttons (Create Utility and View Utility) become available. Parametric/LP Utility Selection Group If any Parametric Utilities exist in the case, you can select one by clicking the Browse button. The Browse button opens the Select Parametric Utility property view, as shown in the following figure. Select the Parametric Utility to be used for the unit operation, and click OK. Figure 5.1255-191 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-192 Parametric Unit Operation ww ThCreate Utility Button If a Parametric Utility does not exist in the HYSYS case or if you want to create a new Utility, click the Create Utility button to creates one for use in the Parametric unit operation. View Utility Button To view the selected Parametric Utility, click the View Utility button. Inputs from a Data File Radio Button When using this option, the Parametric unit operation does not have to obtain the model parameter from a utility. Instead, an external data file can be used. Data File Format Group In the Data File Format group, you can select the format of information to be stored in the *.dat file. • The format for the Row is: input11, input21, input31, ... output11, output21, output31, ... input12, input22, input32, ... output12, output22, output32, ... • The format for the Column is: Data File Selection Group Clicking the Browse button allows you to navigate, and locate the data file that contains the required information for the Parametric model. The information in the file is comma delimited and is stored in a *.dat file. input11 input12 output11 output12 input21 output22 output21 output22 input31 input32 output31 output32 ... ... ... ...5-192 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-193 ww ThInput Units from Data File Field Using the drop-down list, the units used in the data file can be defined. Modeled Streams for Input–Output Group The input and output streams that are being modeled can be selected from the list of existing streams in the drop-down list. A new stream can be created and used in the Parametric unit operation by entering a new stream name in the appropriate cell. View Data Button The View Data button is available in both the Connections page and Setup page. Clicking the View Data button opens the Data Presentation property view. In this property view, you can see the data from the *.dat file in graph format. The radio button and checkbox in the Plot column allow you to select which data set appears on the graph. Figure 5.1265-193 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-194 Parametric Unit Operation ww ThYou can also specify the high and low limits for each data set, using the High Value and Low Value fields. When you specify the range of data set, the Parametric Unit Operation only takes the data within the range to use for training. So the High Value and Low Value fields allow you to discard any initial and end data values that may be inaccurate. Setup Page The appearance of this page, like the Connections page, is dependant on the radio button selected in the Input Data group on the Connections page. Use Utility Data Radio Button When the Use Utility Data radio button is selected, the property view appears as shown in the figure below. Available Unit Op Models from Utility Group When the Use Utility Data radio button is selected on the Connections page, only one group is available on the Setup page. In this table, all unit operations that have a Parametric model in the selected Parametric Utility appear. The name of the unit operation, the status of the model activity, and the operation status of the unit operations are all displayed. The Model Activity can be chosen to be active or inactive by clicking Figure 5.1275-194 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-195 ww Ththe checkbox. When the model is inactive, it is only removed from the Parametric Utility. Inputs from a Data File Radio Button When the Inputs from a Data File radio button is selected, the property view appears as shown in the figure below. The Setup page contains two groups: • Data Mapping • Training Pair Status Data Mapping Group Two radio buttons are available in this group: Inputs and Outputs. The table below describes the properties displayed. Figure 5.128 Property Description Number of Training Pairs The number of data sets read in from the data file. Data Point A specific data within the data file. Mapped Variable The variable in the attached stream that is associated to the data set. Variable Type The variable type of the data point, which is selected from the drop-down list. Identifier Allows you to enter a unique name to identify the data points.5-195 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-196 Parametric Unit Operation ww ThTraining Pair Status Group Displays the individual training pairs, and indicates whether the pair contains bad data. If an ‘X’ appears, there is no bad data. If a checkmark appears, there is bad data in the data set. Notes Page The Notes page provides a text editor, where you can record any comments or information regarding the operation or to your simulation case in general. 5.6.3 Training Tab The Training tab displays the training variables of the attached Parametric Utility. There are four main objects in the Training tab: • Connected Unit Operations. The number of unit operations connected to the Parametric unit operation appears in this field. • Manipulated Variables. By selecting the Manipulated radio button, the manipulated variables in the Parametric model appear. The manipulated variables are the variables being modified in the Parametric Utility and obtained from the HYSYS PFD model simulation. The name of the variable appears, and the selected status is shown. You can select or deselect the variable for use in the parametric model by clicking the checkbox. The lower and upper values used for training are also displayed. Low and High Value The minimum and maximum values in the data set. Bad Variable Status If an ‘X’ appears, the data is good. If a checkmark appears, there is bad data in the data set. Current Value The value used in the worksheet after training. A training pair is defined as a set of input and output data. Property Description For more information, refer to Section 1.3.5 - Notes Page/Tab.5-196 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-197 ww Th• Observable Variables. By selecting the Observable radio button, the observable variables in the Parametric model appear. The observable variable is the same as the Observable variable in the Parametric Utility. Observable variables are the HYSYS variables whose values are known and used as training data when calculating the Parametric model. The name of the variable appears and the selected status is shown. You can select or deselect the variable for use in the Parametric model calculation by clicking the checkbox. The lower and upper values for training are also displayed. • Train Button. Clicking the Train button initializes the Parametric Utility training engine to determine the parameters for the Parametric model. The Parametric model approximates the HYSYS model in the sense that, given the same values of the training input variables, the values of the output variables of the Parametric model must be close to the values from the HYSYS model. 5.6.4 Worksheet Tab The Worksheet tab displays the various Conditions, Properties, and Compositions of the unit operations, streams, and variables that are using the Parametric model. From here you can use the neural network instead of the flowsheet, and where the training pairs have been used from a file, see how the neural network has modeled the operation from which your training pairs were generated. These objects appear as different pages on the tab. 5.6.5 Validation Tab The final step before using the Neural Network is to validate the results. In the validation process, a new set of input data is given to both the HYSYS model and the Neural Network. It is important to realize that there are no methods for training neural networks that can “magically” create information that is not contained in the training data. The neural network model is only as good as its training data. For more information on the Workbook, refer to Section 7.23 - Workbook in the HYSYS User Guide.5-197 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-198 Recycle ww ThThe Validation options are described below: 5.7 Recycle The capability of any flowsheet simulator to solve recycles reliably and efficiently is critical. HYSYS has inherent advantages over other simulators in this respect. It has the unique ability to back-calculate through many operations in a non-sequential manner, allowing many problems with recycle loops to be solved explicitly. For example, most heat recycles can be solved explicitly (without a Recycle operation). Material recycles, where downstream material mixes with upstream material, require a Recycle operation. The Recycle installs a theoretical block in the process stream. The stream conditions can be transferred either in a forward or backward direction between the inlet and outlet streams of this block. In terms of the solution, there are assumed values and calculated values for each of the variables in the inlet and outlet streams. Depending on the direction of transfer, the assumed value can exist in either the inlet or outlet stream. For example, if the user selects Backward for the transfer direction of the Temperature variable, the assumed value is the Inlet stream temperature and the calculated value is the Outlet stream temperature. The following steps take place during the convergence process: 1. HYSYS uses the assumed values and solves the flowsheet Button Description PM runs Runs the Parametric model to generate validation data based on the Parametric model. HYSYS runs Runs the HYSYS model to generate validation data based on the HYSYS model. View Results Table... Allows the viewing of validation data in table format. Compares the HYSYS validation data with Parametric model data. View Results Graph... Allows the viewing of validation data in graphical format. Compares the HYSYS validation data with Parametric model data.5-198 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-199 ww Tharound the recycle. 2. HYSYS then compares the assumed values in the attached streams to the calculated values in the opposite stream. 3. Based on the difference between the assumed and calculated values, HYSYS generates new values to overwrite the previous assumed values. 4. The calculation process repeats until the calculated values match the assumed values within specified tolerances. 5.7.1 Recycle Property View There are two ways that you can add a Recycle to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Logicals radio button. 3. From the list of available unit operations, select Recycle. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the Recycle icon. Recycle icon5-199 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-200 Recycle ww ThThe Recycle property view appears. 5.7.2 Connections Tab The Connections tab contains the following pages: • Connections • Notes Connections Page The Connections page consists of the four fields: • Name. The name of the Recycle operation. • Inlet. Holds the inlet stream, which is the latest calculated recycle; it is always a product stream from a unit operation. • Outlet. Contains the outlet stream, which is the latest assumed recycle; it is always a feed stream to a unit operation. Figure 5.129 Object Description Continue button Enables you to run the calculation after the maximum iteration has been reached. Recycle Assistant button Enables you to access the Recycle Assistant property view. Refer to Section 5.7.9 - Recycle Assistant Property View for more information.5-200 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-201 ww Th• Fluid Package. The fluid package associated to the operation can be selected by entering the fluid package name or using the drop-down list. Notes Page The Notes page provides a text editor, where you can record any comments or information regarding the operation or to your simulation case in general. 5.7.3 Parameters Tab The Parameters tab contains the following pages: • Variables • Numerical If RefSYS is installed, the Parameters tab has a Convergence page. Variables Page HYSYS allows you to set the convergence criteria factor for each of the variables and components listed. The sensitivities values you enter actually serve as a multiplier for HYSYS internal Figure 5.130 For more information, refer to Section 1.3.5 - Notes Page/Tab.5-201 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-202 Recycle ww Thconvergence tolerances. Figure 5.1315-202 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-203 ww ThThe internal absolute tolerances, except flow which is a relative tolerance, are shown in the table below. For example, the internal tolerance for temperature is 0.01 and the default multiplier is 10, so the absolute tolerance used by the Recycle convergence algorithm is 0.01*10 = 0.1. Therefore, the assumed temperatures and the calculated temperature must be within 0.1°C (where C is the internal units) of each other if the Recycle is to converge. HYSYS always convert the values entered to the internal units before performing calculations. A multiplier of 10 (default) is normal, and is recommended for most calculations. Values less than 10 are more stringent; that is, the smaller the multiplier, the tighter the convergence tolerance. HYSYS Internal Tolerances Variable Internal Tolerance Vapour Fraction 0.01 Temperature 0.01 Pressure 0.01 Flow 0.001** Enthalpy 1.00 Composition 0.0001 Entropy 0.01 **Flow tolerance is relative rather than absolute The internal Vapour Fraction tolerance, when multiplied by the recycle tolerance, is 0.1 which appears to be very loose. However, in most situations, if the other recycle variables have converged, the vapour fraction in the two streams are identical. The loose Vapour Fraction tolerance is critical for close-boiling mixtures, which can vary widely in vapour fraction with minimal difference in other properties. It is not required that each of the multipliers be identical. For example, if you are dealing with ppm levels of crucial components, you can set the Composition tolerance multiplier much tighter (smaller) than the others.5-203 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-204 Recycle ww ThThe Transfer Direction column allows you to select the transfer direction of the variable. There are three selections: • not to transfer • transfer forward • transfer backward Not Transferred option can be used if you only want to transfer certain stream variables. For example, if you only want to transfer P, T composition and flow, the other variables could be set to Not Transferred. When you select the Take Partial Steps checkbox, the Recycle operation takes calculation steps on any variables whenever the calculations are possible. When you clear the checkbox, the Recycle operation waits until all of the inlet stream flowing into the operation is complete before performing the next calculation step. The default setting for this checkbox is clear. In addition to converging on physical properties basis, the Recycle operation also converges on individual component tolerances. The components in the recycle stream are automatically added to the Recycle logical operation. When you select the Use Component Sensitivities checkbox, the single composition sensitivities value is automatically overridden by the individual component sensitivities values and the Recycle operation takes calculation steps on each value when applicable. The default setting for this checkbox is inactive. Once you select the Use Component Sensitivities checkbox, the tolerances for each component in the recycle stream are listed in the table. By default, the sensitivities value is set at 10.00 for each component. Any changes that you make to the sensitivities value are automatically saved.5-204 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-205 ww ThNumerical Page The Numerical page contains the options related to the Wegstein Acceleration Method. This method is used by the Recycle to modify the values it passes from the inlet to outlet streams, rather than using direct substitution. The table below describes the parameters on the Numerical page. Figure 5.132 Numerical Parameters Description Mode You can choose between Nested or Simultaneous mode by selecting the respective radio button. The default mode is Nested. Acceleration You can choose between two methods of acceleration: • Wegstein. Ignores interactions between variables being accelerated. • Dominant Eigenvalue. Includes interactions between variables being accelerated. Further, the Dominant Eigenvalue option is superior when dealing with non-ideal systems or systems with strong interactions between components. Maximum Iterations The number of iterations before HYSYS stops (the default is 10). You can continue with the calculations by clicking the Continue button at the bottom of the Recycle property view. Iteration Count The number of iterations before an acceleration step is applied to the next iteration (default is 0). Flash Type The Flash method to be implemented by the Recycle unit op. Refer to the Type of Recycle section for more information.5-205 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-206 Recycle ww ThType of Recycle There are two choices for the type of Recycle: • Nested • Simultaneous The Nested option results in the Recycle being called whenever it is encountered during the calculations. In contrast, the Simultaneous option causes all Recycles to be invoked at the same time once all recycle streams have been calculated. If your flowsheet has a single Recycle operation, or if you have multiple recycles which are not connected, use the Nested option (default). If your flowsheet has multiple inter-connected recycles, use the Simultaneous type. There are several additional points worth noting about the Recycle: • When the Recycle cannot be solved in the number of iterations you specify, HYSYS stops. If you decide that the problem may converge with more iterations, simply click the Continue button. The Recycle initializes the iteration counter and continues until a solution is found or it again runs out of iterations. • If your problem does not converge in a reasonable number of iterations, there are probably constraints in your flowsheet which make it impossible to solve. In particular, if the size of the recycle stream keeps growing, it is likely that the flowsheet does not permit all Acceleration Frequency The value in this field is the number of steps to go before putting in acceleration. The lower the value, the more often variables get accelerated. Q maximum/ Q minimum Damping factors for the acceleration step (defaults are 0 and -20). Acceleration Delay This delays the acceleration until the specified step (default is 2). The Calculation Level for a Recycle (accessed under Main Properties) is 3500, compared to 500 for most streams and operations. This means that the Recycle is solved last among unknown operations. You can set the relative solving order of Recycles by modifying the Calculation Level. Numerical Parameters Description5-206 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-207 ww Thof the material entering the flowsheet to leave. An example of this occurs in gas plants when you are trying to make a liquid product with a low vapour pressure and a vapour product which must remain free of liquids even at cold temperatures. Often, this leaves no place for intermediate components like propane and butane to go, so they accumulate in the plant recycle streams. It is also possible that the tolerance is too tight for one or more of the Recycle variables and cannot be satisfied. This can readily be determined by examining the convergence history, and comparing the unconverged variable deviations with their tolerances. • The logical operations (such as the Recycle, Adjust and Controller) are different from other operations in that they actually modify the specifications of a stream. As a result, if you remove any of these operations, the outlet stream specifications remain. Thus, nothing in the flowsheet is “forgotten” for these operations. You can Delete or Ignore a Recycle when you want to make flowsheet modifications, but do not want to invoke the iterative routines. • Tolerance settings are important to a successful Recycle solution. This is especially true when multiple recycles are involved. If there is no interaction among the recycles, or if they are inter-connected and are being solved simultaneously, tolerance values can be identical for all Recycles if desired. However, if the Recycles are nested, tolerances should be made increasingly tighter as you go from the outermost to the innermost Recycle. Without this precaution, the outside Recycle may not converge. Maximum Number of Iterations When HYSYS has reached the maximum number of iterations, a warning message appears stating that the Recycle failed to converge in the specified number of iterations. You can then choose whether or not to continue calculations. If you are starting a new flowsheet, use a small number of Maximum Iterations, such as 3. Once it is evident that the calculations are proceeding well, the count can be increased. The iterations required depend not only on the complexity of The Monitor tab provides a history of the Recycle calculations.5-207 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-208 Recycle ww Thyour flowsheet, but also on your initial estimate and the convergence tolerances you use. Damping Factors - Qmax and Qmin The Wegstein acceleration method uses the results of previous iterations in making its guesses for the recycle stream variables. Assumed values are calculated as follows: where: X = assumed value Y = calculated value n = iteration number Q = acceleration factor HYSYS determines the actual acceleration (Q) to apply based on the amount of change between successive iterations. The values for Qmax and Qmin set bounds on the amount of acceleration applied. Note from the equation that when Q = 0, direct replacement is used. When Q is negative, acceleration is used. When Q is positive and smaller than 1, damping occurs. Iteration Count The Iteration Count is the number of Recycle iterations before an acceleration step is applied when calculating the next assumed recycle value. The default count is 3; after three iterations (assuming the Acceleration Delay is less than 3), the assumed and calculated recycle values are compared and the Wegstein acceleration factor is determined and applied to the (5.27) If you are finding that your Recycle is still oscillating, even with the Iteration Count set to ensure direct replacement, you can input a slightly larger value for Qmax to damp the direct replacement. Xn 1+ QXn 1 Q–( )Yn+=5-208 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-209 ww Thnext assumed value. When the acceleration factor is not being used (in all iterations up to the Iteration Count), the next assumed value is determined by direct replacement. Notice that Acceleration Delay takes precedence over the Iteration Count. This means that for an Acceleration Delay value of x, the initial x iterations use direct replacement, even if the Iteration Count is set to less than x. The x+1 iteration uses the acceleration after which the Iteration Count applies. Although acceleration generally works well for most problems, in some cases it may result in over-correction, oscillation, and possibly non-convergence. Examples of this type of problem include highly-sensitive recycles and multiple recycle problems with strong interactions among recycles. In cases such as these, direct replacement may be the best method for all iterations. To eliminate the use of acceleration, simply set the Iteration Count (or Acceleration Delay) to a very high number of iterations (for example, 100) which is never reached. In the rare instance where even direct replacement causes excessive over- corrections, damping is required. Use the set of parameters discussed below to control this. Acceleration Delay The Acceleration Delay parameter delays the acceleration until the specified step. This delay applies to the initial set of iterations and once the specified step is reached the Iteration Count is applied. That is to say no acceleration is performed until the delay value is reached and after that iteration the Figure 5.133 iterations Recycle Iterations Begin N I I I I AD - Acceleration Delay I - Iteration Count if I AD then N = AD+1 else if I > AD then N = I≤5-209 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-210 Recycle ww Thacceleration is applied according to the Iteration count. The default is specified as 2 but now it can be specified to any value. For example, if the 'delay' is set to 5 and the Iteration Count is 3 then the first 5 iterations use direct replacement and the sixth uses acceleration then after every third iteration the acceleration step is applied. Convergence Page The Convergence page contains information about transferring and converging petroleum properties across the recycle. On this page, you can • individually set each property as an active specification during the recycle convergence • adjust the tolerance for each property • view the current value for each property 5.7.4 Worksheet Tab The Worksheet tab displays the various Conditions, Properties, and Compositions of the Feed and Product streams. 5.7.5 Monitor Tab The Monitor tab contains the following pages: • Setup • Tables Note: The Convergence page only appears when RefSYS is installed. For more information refer to Section 1.3.10 - Worksheet Tab.5-210 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-211 ww Th• Plots The Setup page allows you to specify which variables you want to view or monitor. To view a variable, select the View checkbox corresponding to the variable of interest. The Tables page and Plots page display the convergence information as the calculations are performed in tabular and graphical format respectively. The inlet value, outlet value, and variable are shown, along with the iteration number. This is illustrated in the following figure. Figure 5.134 Figure 5.135 Tables page Plots page5-211 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-212 Recycle ww Th5.7.6 User Variables Tab The User Variables tab enables you to create and implement your own user variables for the current operation. 5.7.7 Calculations HYSYS provides a very simple means of solving recycle problems, and its interactive nature provides a high degree of control and feedback to the user as to how the solution is proceeding. The Recycle can be set up as a single unit operation to represent a single recycle stream in a process flowsheet, or a number of them can be installed to represent multiple recycles, interconnected or nested, as well as a combination of interconnected and nested recycle loops. Similar to the multi- Adjust operation, the Recycle solves all the recycle loops simultaneously, if requested to do so. The step-by-step procedure for setting up a recycle is as follows: 1. Make a guess for the assumed values in the stream attached to the recycle operation (temperature, pressure, flow rate, composition). The flow rate can generally be zero, but, In Dynamic mode, HYSYS ignores the Recycle operation. So in the case of the outlet stream, it is identical to the inlet stream. For more information refer to Section 1.3.8 - User Variables Page/ Tab.5-212 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-213 ww Thobviously, better estimates results in faster convergence. 2. Build your flowsheet until the calculated values in the connected streams can be determined by HYSYS. 3. Install the Recycle block. 5.7.8 Reducing Convergence Time Selection of the recycle tear location is vitally important in determining the computer run time to converge the Recycle. Although the physical recycle stream itself is often selected as the tear stream, the flowsheet can be broken at virtually any location. In simulating a complex system, a number of factors must be considered. The following are some general guidelines: • Choose a Tear Location to Minimize the Number of Recycles Reducing the number of locations where the iterative process is required save on total convergence time. Choosing the location of the Recycle depends on the flowsheet topology. Attempt to choose a point such that specifying the assumed values defines as many streams downstream as possible. It generally occurs downstream of gathering points and upstream of distribution points. Examples include downstream of mixers (often mixing points where the physical recycle combines with the main stream), and upstream of tees, separators, and columns. • Choose a Tear Location to Minimize the Number of Recycle Variables Variables include vapour fraction, temperature, pressure, flow, enthalpy, and composition. Choose the tear stream so that as many variables as possible are fixed, thus effectively eliminating them as variables and increasing If the recycle is a feed to a tower, a reasonable estimate is needed to ensure that the column converges the first time it is run. The outlet and inlet recycle streams must have different names.5-213 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-214 Recycle ww Thconvergence stability. Good choices for these locations are at separator inlets, compressor aftercooler outlets, and trim heater outlets. • Choose a Stable Tear Location The tear location can be chosen such that fluctuations in the recycle stream have a minimal effect. For example, by placing the tear in a main stream, instead of the physical recycle, the effect of fluctuations are reduced. The importance of this factor depends on the convergence algorithm. It is more significant when successive substitution is used. Choosing stable tear locations is also important when using simultaneous solution of multi-recycle problems. 5.7.9 Recycle Assistant Property View The Recycle Assistant property view enables you to find places to insert Recycle unit operation that make the simulation case convergent easily. There are two other functionalities in the Recycle Assistant feature: • Enables you to analyse the flowsheet to get suggested tear streams. • Enables you to delete and add Recycle Unit Op in the Recycle Assistant’s interface. For the delete option, only one Recycle Unit op can be deleted at one time. To access the Recycle Assistant property view, do one of the following: • In the HYSYS menu bar, select the Tools | Recycle Assistant command. • Open the Recycle operation property view, and click the Recycle Assistant button. Avoid choosing tear streams which have variables determined by an Adjust operation. The feature is only available in Steady State mode.5-214 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-215 ww ThThe Recycle Assistant property view appears. The options in the Recycle Assistant property view are split into the following tabs: • Flowsheet Analysis • Recycle Setup Figure 5.1365-215 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-216 Recycle ww ThFlowsheet Analysis Tab The Flowsheet Analysis tab enables you to add, modify, and delete recycle operations and analyse the flowsheet. Figure 5.137 Object Description Current Recycles and Tear Streams group Displays two lists of all the recycles and associate tear streams available in the PFD. Delete Recycle button Enables you to delete the selected recycle operation in the list. Suggested Tear Streams group Displays a list of possible tear streams available in the PFD. Add Recycle button Enables you to add a recycle to the selected tear stream in the list. Rebuild button Enables you to modify and optimize the process flow diagram using the suggested tear streams and recycles. Analyse Flowsheet button Enables you to update the list of available tear stream in the PFD.5-216 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-217 ww ThRecycle Setup Tab The Recycle Setup tab enables you to modify the variable sensitivity of the selected recycle operation. Figure 5.138 Object Description Current Recycle Ops list Displays the list of available recycle operations in the PFD. Vapour Fraction cell Enables you to modify the vapour fraction sensitivity. Temperature cell Enables you to modify the temperature sensitivity. Pressure cell Enables you to modify the pressure sensitivity. Flow cell Enables you to modify the flow rate sensitivity. Enthalpy cell Enables you to modify the enthalpy sensitivity. Composition cell Enables you to modify the composition sensitivity. Entropy cell Enables you to modify the entropy sensitivity. Using Component Sensitivities checkbox Enables you to toggle between including or discarding the sensitivity values based on the components in the PFD. Component table Enables you to modify the component sensitivity values for all the components in the PFD. Current Values group Displays the same options available in the Variable Sensitivities table, except the variable values are taken from the selected recycle operation in the Current Recycle Ops list.5-217 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-218 Selector Block ww Th5.8 Selector Block The Selector Block is a multiple-input single-output controller, that provides signal conditioning capabilities. It determines an Output value based on a user-set Input function. For instance, if you want the maximum value of a specific variable for several Input streams to dictate the Output, you would use the Selector Block. A simple example would be where a Selector Control chooses the average temperature from several temperature transmitters in a Column, so that the Reboiler duty can be controlled based on this average. 5.8.1 Selector Block Property View There are two ways that you can add a Selector Block to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Logicals radio button. 3. From the list of available unit operations, select Selector Block. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. Apply to Selection button Enables you to apply the modified variable sensitivities values to the selected recycle operations in the Current Recycle Ops list. Apply to All button Enables you to apply the modified variable sensitivities values to all the recycle operations in the PFD. Object Description5-218 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-219 ww Th2. Double-click the Selector Block icon. The Selector Block property view appears. 5.8.2 Connections Tab The Connections tab consists of three objects described in the table below: Figure 5.139 Objects Description Selector Name Contains the name of the Selector Block, which can be edited at any time. Process Variable Sources Contains the variables the Selector Block considers and inserted into the input function. The Process Variables for the various inputs are targeted by clicking Add PV button, accessing the Variable Navigator. You can edit or delete any current PV by positioning the cursor in the appropriate row, and clicking the Edit PV or Delete PV buttons. If you add a Variable whose type is inconsistent with the current Input Variables, HYSYS displays an error message. However, you are allowed to retain that Variable. OP Target Contains the process variable, which is manipulated by the Selector Block. To select the OP Target click the Select OP button. This button also accesses the Variable Navigator. Notice that it is not necessary for the Target Variable type to match the Input Variable type. Selector Block icon Refer to Section 1.3.9 - Variable Navigator Property View for information.5-219 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-220 Selector Block ww Th5.8.3 Parameters Tab The Parameters tab contains the following pages: • Selection Mode • Scaling Factor Selection Mode Page The Selection Mode page allows you to select the mode and parameters of the operation. Figure 5.140 Figure 5.141 When the Apply Unit Set checkbox is clear, the operation uses default internal HYSYS units (in other words, no real unit conversion) for the calculations.5-220 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-221 ww ThIn the Mode group, you can choose from the following modes: When the Apply Unit Set checkbox is selected, you can select a unit set and variable type for the calculations and output respectively. In the Parameters group, you can specify the following parameters: • Calculation Unit Set. You can select the unit set you want the calculations done with using the drop-down list. There are three standard selections: SI, EuroSI, and Field. You can create your own unit set in the Session Preferences property view. Modes Description Off Select this mode to disable the Selector Block. The function of this mode is similar to the Ignored checkbox in the unit operations. Minimum The minimum value from the list of Input Variables is passed to the Output stream. Maximum The maximum value from the list of Input Variables is passed to the Output stream. Median The median value of the Input Variables is passed to the Output stream. If there are an even number of Input Variables, then the higher of the two middle values is passed to the Output stream. Average The average of the Input Variables is passed to the Output stream. Sum The sum of the Input Variables is passed to the Output stream. Product The product of the Input Variables is passed to the Output stream. Quotient The quotient of the Input Variables is passed to the Output stream. Manual This mode is similar to Manual mode in the PID controller. This mode allows you to specify the OP directly. Hand Sel Allows you to select which Input Variable value is written to the OP. You can select the PV value using the Selected Input field. Figure 5.142 Refer to Section 12.3.1 - Units Page in the HYSYS User Guide for more information.5-221 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-222 Selector Block ww Th• Selected Input. You can select the PV source using the drop-down list in this field. This field is only available for the Minimum, Maximum, and Hand Sel modes. Scaling Factors Page The Scaling Factors page allows you to manipulate the input and output parameters. The Output is a function of the Mode, Gain, and Bias, where the Input function is dependent on the mode: The Input function is multiplied by the Gain. In effect, the gain tells how much the output variable changes per unit change in the input function. The Bias is added to the product of the Input function and Gain. Inputs can be individually scaled before the output calculations. Figure 5.143 (5.28) If you want to view the Input function without any Gain or Bias adjustment, set the Gain to one and the Bias to zero. (5.29) Output f Inputs( ) Gain Bias+×= Inputscaled Input Gain Bias+×=5-222 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-223 ww ThThe Inverse Cond. checkbox is used when the selector is writing back to its PV, and you are required to scale the input value backwards. 5.8.4 Monitor Tab The Monitor tab displays the results of the Selector Block. It consists of two objects: • Input PV Data. This group contains the current values of the input process variable. • Output Value. This display field contains the current value of the PV for each of the input variables and the Output Value is also displayed on the Parameters tab. (5.30) Figure 5.144 The Output value is not displayed until the Integrator has been started. Input Inputscaled Bias– Gain ------------------------------------------=5-223 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-224 Selector Block ww ThExample In the simple example shown here, the median value of Stream 1, Stream 2, and Stream 3 is passed to the Output, after a Gain of 2 and a Bias of 5 have been applied. These are the steps: 1. Determine f(Inputs), which in this case is the median of the Input Variables. The median (middle value) temperature of the three streams (10°C, 15°C, 20°C) is 15°C. 2. Determine the Output Value, from the Gain and Bias. The Gain is 2, and the Bias is 5°C. 3. The Output is calculated as follows: 5.8.5 Stripchart Tab The Stripchart tab allows you to select and create default strip charts containing various variable associated to the operation. 5.8.6 User Variables Tab The User Variables tab enables you to create and implement your own user variables for the current operation. (5.31) Output f Inputs( ) Gain Bias+×= Output 15°C 2.000 5.000°C+×= Output 35°C= Refer to Section 1.3.7 - Stripchart Page/Tab for more information. For more information refer to Section 1.3.8 - User Variables Page/ Tab.5-224 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-225 ww Th5.9 Set The Set is an operation used to set the value of a specific Process Variable (PV) in relation to another PV. The relationship is between the same PV in two like objects; for instance, the temperature of two streams, or the UA of two exchangers. The dependent, or target, variable is defined in terms of the independent, or source, variable according to the following linear relation: where: Y = dependent (target) variable X = independent (source) variable M = multiplier (slope) B = offset (intercept) 5.9.1 Set Property View There are two ways that you can add a Set to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Logicals radio button. 3. From the list of available unit operations, select Set. 4. Click the Add button. OR The Set unit operation can be used in both Dynamic and Steady State mode. (5.32)Y MX B+=5-225 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-226 Set ww Th1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the Set icon. The Set property view appears. 5.9.2 Connections Tab On the Connections tab, you can specify the following information: • Target Object. The stream or operation to which the dependent variable belongs. This is chosen by clicking the Select Var button. This brings up the Variable Navigator property view. • Target Variable. The type of variable you want to set, for example, temperature, pressure, and flow. The available choices for Variable are dependent on the Object type (stream, heat exchanger, and so forth) Your choice of Variable is automatically assigned to both the Target and Source object. • Source Object. The stream or operation to which the independent variable belongs. Notice that when you choose an object for the Target, the available objects for the Source are restricted to those of the same object type. For example, if you choose a stream as the Target, only streams are available for the Source. Figure 5.145 Set icon Refer to Section 1.3.9 - Variable Navigator Property View for more information.5-226 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-227 ww ThHYSYS solves for either the Source or Target variable, depending on which is known first (bi-directional solution capabilities). 5.9.3 Parameters Tab On the Parameters tab, you can specify values for the slope (Multiplier) and the intercept (Offset). The default values for the Multiplier and Offset are 1 and 0, respectively. Figure 5.146 Figure 5.1475-227 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-228 Spreadsheet ww Th5.9.4 User Variables Tab The User Variables tab enables you to create and implement your own user variables for the current operation. 5.10 Spreadsheet The Spreadsheet applies the functionality of Spreadsheet programs to flowsheet modeling. With essentially complete access to all process variables, the Spreadsheet is extremely powerful and has many applications in HYSYS. The Spreadsheet can be used to manipulate or perform custom calculations on flowsheet variables. Because it is an operation, calculations are performed automatically; Spreadsheet cells are updated when flowsheet variables change. In Dynamics mode, the Spreadsheet cells are updated when the integrator is running. One application of the Spreadsheet is the calculation of pressure drop during dynamic operation of a Heat Exchanger. In the HYSYS Heat Exchanger, the pressure drop remains constant on both sides regardless of flow. However, using the Spreadsheet, the actual pressure drop on one or both sides of the exchanger could be calculated as a function of flow. Complex mathematical formulas can be created, using syntax which is similar to conventional Spreadsheets. Arithmetic, logarithmic, and trigonometric functions are examples of the mathematical functionality available in the Spreadsheet. The Spreadsheet also provides logical programming in addition to its comprehensive mathematical capabilities. Boolean logic is supported, which allows you to compare the value of two or more variables using logical operators, and then perform the appropriate action depending on that result. The HYSYS Spreadsheet has standard row/column functionality. You can import a variable, or enter a number or formula anywhere in the spreadsheet. For more information refer to Section 1.3.8 - User Variables Page/ Tab.5-228 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-229 ww ThYou can import virtually any variable in the simulation into the Spreadsheet, and you can export a cell's value to any specifiable field in your simulation. There are two methods of importing and exporting variables to and from the Spreadsheet: When you are using the Spreadsheet to return a result back to the flowsheet, you must consider its application in terms of the overall calculation sequence, particularly when Recycles are involved. If the Spreadsheet performs a calculation and sends the results back upstream, the potential exists for creating inconsistencies as the full effect of the previous Recycle loop has not propagated through the flowsheet. By using the Calculation Sequencing option, you can minimize the potential for problems of this nature. 5.10.1 Spreadsheet Property View There are two ways that you can add a Spreadsheet to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. Methods Description Using the Variable Navigator Do one of the following: • On the Connections tab, click the Add Import or Add Export button. • On the Spreadsheet tab, right-click the cell you want and select export/import command from the object inspection menu. Then using the Variable Navigator, select the variable you want to import or export. Dragging Variables Simply right-click the variable value you want to import, and drag it to the desired location in the Spreadsheet. If you are exporting the variable, drag it from the Spreadsheet to an appropriate location. When using the Dragging Variables method, the property views have to be non-modal. Refer to Section 1.3.9 - Variable Navigator Property View for more information. Refer to Section 7.2 - Main Properties in the HYSYS User Guide for more information on the Calculation Sequencing option.5-229 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-230 Spreadsheet ww Th2. Click the Logicals radio button. 3. From the list of available unit operations, select Spreadsheet. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the Spreadsheet icon. The Spreadsheet property view appears. 5.10.2 Spreadsheet Functions The HYSYS Spreadsheet has extensive mathematical and logical function capability. To view the available Spreadsheet Functions and Expressions, click the Function Help button to open the Available Expressions and Functions property view. Figure 5.148 All functions must be preceded by “+” (straight math) or “@” (special functions like logarithmic, trigonometric, logical, and so forth). Examples are "+A4/B5" and "@ABS(A4-B5)". Spreadsheet icon Click the Function Help button to access the list of available spreadsheet functions in HYSYS. Click the Spreadsheet Only button to open the a property view containing only the spreadsheet and its content.5-230 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-231 ww ThThe Available Expressions and Functions property view contains the following tabs: • Mathematical Expressions • Logical Expressions • Mathematical Functions General Math Functions The following arithmetic functions are supported: Several other mathematical functions are also available: General Operations Method of Application View Addition Use the “+” symbol. Subtraction Use the "-" symbol. Multiplication Use the “*” symbol. Division Use the “/” symbol, typically located on the numeric keypad, or next to the right SHIFT key. (Do not use the “\” symbol). Absolute Value “@Abs”. Advanced Operations Method of Application View Power Use the “^” symbol. Example: +3^3 = 27 Example 2: +27^(1/3)=3 Notice that the parentheses are required in this case, since the cube root of 27 (or 27 to the power of one-third) is desired. Square Root "@SQRT". Example: @sqrt(16) = 4 Notice that capitalization is irrelevant. You can also use “@RT” to calculate a square root. (Example: @rt(16)=4) Refer to the Calculation Hierarchy section for more information.5-231 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-232 Spreadsheet ww ThCalculation Hierarchy The usual hierarchy of calculation is used (Brackets, Exponents, Division and Multiplication, Addition and Subtraction). For example: +6+4/2 = 8 (not 5) since division is performed before addition. However, +(6+4)/2 = 5 because any expressions in parentheses are calculated first. Logarithmic Functions Pi Simply enter "+pi" to represent the number 3.1415... Factorial Use the “!” symbol. Example: +5!- 120=0 Log Function Method of Application View Natural Log “@ln”. Example: @ln(2.73)=1.004 Base 10 Log "@log". Example: @log(1000)=3 Exponential “@exp”. Example: @exp(3)=20.09 Hyperbolic “@sinh”, “@cosh”, “@tanh”. Example: @tanh(2) = 0.964 Expression within Range “@Inrange” Returns a 1 if the number is within the range specified within the function. Example: A1 = 5 • @Inrange(A1,4,7) = 1 • @Inrange(A1,6,10) = 0 Advanced Operations Method of Application View5-232 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-233 ww ThTrigonometric Functions All of the trigonometric functions are supported, including inverse and hyperbolic functions: Trigonometric functions can be calculated using radian, degree or grad units, by selecting the appropriate type from the Angles in drop-down list in the Current Cell group. Expression within Limit “@Inlimit” Returns a 1 if the number is within the range, on either side of the number, specified within the function. Example: A1 = 5 • @Inlimit(A1,7,2) = 1 • @Inlimit(A1,7,1) = 0 Expression within Percentage “@Inpercentage” Returns a 1 if the number is within the percentage, on either side of the number, specified within the function. Example: A1 = 5 • @Inpercentage(A1,8,40) = 1 • @Inpercentage(A1,8,35) = 0 Trig Function Method of Application View Standard “@sin”, “@cos”, “@tan”. Example: @cos(pi) =-1 (Radian Angles) Inverse “@asin”, “@acos”, “@atan”. In this case, the number to which the function is being applied must be between -1 and 1. Example: @asin(1) = 1.571 (Radian Angles) Parentheses are required for all logarithmic and trigonometric functions. The capitalization is irrelevant; HYSYS calculates the function regardless of how it is capitalized. Log Function Method of Application View5-233 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-234 Spreadsheet ww ThLogical Operators The Spreadsheet supports Boolean logic. For example, suppose cell A1 had a value of 5 and cell A2 had a value of 10. Then, in cell A3, you entered the formula (+A1 ” Less Than “<“ Greater Than or Equal to “>=” Less Than or Equal to “<=” You always need to provide an ELSE clause (IF/THEN statements are not accepted). Parentheses are mandatory for IF/THEN/ELSE statements.5-234 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-235 ww ThFor example, suppose cell B2 contained the number 6. The statement “@if (B2>10) then (10) else (B2/2)” would result in the value 3 being displayed in the cell. 5.10.3 Spreadsheet Interface Importing and Exporting Variables by dragging You can drag the contents of any cell in the simulation into the Spreadsheet. Simply position the pointer on that field, right- click and drag the value to any cell in the Spreadsheet. Figure 5.149 View Type Description Non-Modal A non-Modal property view has a Minimizing button and Maximizing button in the upper-right had corner, and has a double border. You can drag variables outside a non-Modal property view. Modal A Modal property view has a ‘pin’ in the upper-right corner, and has a single border. You cannot drag variables outside a Modal property view. Select the pin to convert a Modal property view to a Non- Modal property view.5-235 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-236 Spreadsheet ww ThWhen you drag to a cell in the Spreadsheet, you see the “bulls- eye” cursor. Release the secondary mouse button, and the value is dropped in that cell. In the Imported From field in the Current Cell group (which appears when the cursor is on an imported cell), you see the Object for that particular cell. The Object Variable appears in the Variable field. Every time you make a change to (or HYSYS re-calculates) a variable you have placed in the Spreadsheet, your data is updated appropriately. You can remove an attachment at any time by positioning the pointer in the appropriate cell, right-clicking and selecting Disconnect Import/Export command from the Object Inspect menu. The window from which you are dragging must be unpinned (non-modal). The Spreadsheet window is non-modal by default. Figure 5.150 Right-click and drag a variable (in this case, Feed Molar Flow) to a cell in the Spreadsheet. You see the bulls-eye cursor, indicating that you can transfer the variable to that location. Release the mouse button and the variable is transferred. In the Imported From cell, you can view the variable source. Object Inspect menu5-236 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-237 ww ThEnumeration in Spreadsheet Similar to the drag-and-drop importing method, the Ignore checkbox of each operation can be imported onto the Spreadsheet page of the Spreadsheet operation. For any unit and logical operations, you can right-click on the Ignore checkbox, and drag-and-drop the bulls-eye onto a spreadsheet cell. For an active operation, the cell should then read 0 - Not Ignored. For a disable operation (in other words, the Ignore checkbox is selected in the operation property view), the cell should read 1-Ignored. The ignore status changes automatically when you select or clear the Ignore checkbox of the corresponding operation. This feature is especially useful when you are working with controllers or actuator fail positions. The ignore status can be used as a number in a formula or in a Boolean expression even though the cell displays the text that reflects the status. Figure 5.1515-237 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-238 Spreadsheet ww ThImporting Variables by Browsing You can also import a variable by positioning the cursor in an empty cell of the Spreadsheet and right-clicking. The Object Inspect menu appears, select the Import Variable command. Using the Variable Navigator select the flowsheet variable you want to import to the Spreadsheet. This method of importing variables is similar to the way variables are imported on the Connections tab. Exporting Formula Results Variables are exported using the Variable Navigator, or by “dragging” the variable. You can only export Formula Results, in other words, values that appear in red. There are three ways to export: • Right-click and drag to the location where you want to export the formula result. You see a bulls-eye cursor indicating that you can export to the current location. Figure 5.152 You can only drag the variables to and fro between non- modal property views. If you export into a field containing a calculated value, you usually get a consistency error, except in the unlikely case that the calculated and exported values are exactly the same. The export value replaces a specifiable value. The Object Inspect menu is accessed by right-clicking the cell in the spread sheet. Refer to Section 1.3.9 - Variable Navigator Property View for more information.5-238 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-239 ww Th• Right-click and select Export Formula Result command from the object inspect menu. Using the Variable Navigator, choose where you want to export the Formula Result. • Define an exported variable on the Connections tab by clicking the Add Export button and selecting the export object and variable using the Variable Navigator. Similarly, the same Spreadsheet cell cannot act as the Source for more than one field. To work around this, type the cell name with the variable you want to export into a new location in the Spreadsheet, and export the new variable. Notice that when you export a variable from a Spreadsheet cell, that variable is given the same units as the units of the location to which you exported it. For example, suppose you wanted to assign the pressure of stream Feed to another stream. In cell B1, enter the formula +A1, and then export the contents of the cell to the pressure cell of the appropriate stream, using one of the methods outlined above. Figure 5.153 You cannot use the same Spreadsheet cell as both the Target and Source field in calculations. Figure 5.154 The object inspect menu is accessed by right- clicking the cell in the spread sheet. Because the contents of cell A1 cannot be both an import and export, the formula +A1 is entered in cell B1. cell B1 is then exported to the Waste pressure.5-239 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-240 Spreadsheet ww ThView Associated Object You can view an object associated with a specific cell by right- clicking and selecting the View Associated Object. For instance, if you dragged the temperature of a stream from the Worksheet into the Spreadsheet, the associated object would be that stream. When you select View Associated Object, you are taken to the property view for that stream. If there is no object associated with the current cell, this menu selection is disabled. 5.10.4 Spreadsheet Tabs Connections Tab On the Connections tab, you can add, edit, and delete Imports and Exports. As mentioned earlier, you can also import and export variables by dragging to and from the Spreadsheet. To add an import, click the Add Import button, and choose the variable using the Variable Navigator. In the Cell column, type or select from the drop-down list the Spreadsheet cell to be connected to that variable. When you move to the For this simple example, you could use the Set operation. For more complex situations, you must use the Spreadsheet. Figure 5.155 You can also view the associated object of an imported cell, by double-clicking on that cell. The Object Inspect menu is accessed by right- clicking the cell in the spread sheet. Refer to Section 1.3.9 - Variable Navigator Property View for more information.5-240 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-241 ww ThSpreadsheet tab, that variable appears in the cell you specified. An example is illustrated in the following figure. You can edit or delete an import by positioning the cursor in the appropriate row, and clicking the Edit Import or Delete Import buttons. Adding, editing, and deleting Exports is performed in a similar manner. You can also edit the Spreadsheet Name on this tab. Parameters Tab On the Parameters tab of the Spreadsheet property view, you can set the dimensions of the Spreadsheet and choose a Unit Set. Figure 5.156 Parameters Description Number of Columns and Rows You can set the dimensions of the Spreadsheet. Notice that if you set the dimensions of the Spreadsheet smaller than what is already specified, you permanently delete the contents of cells which are removed. For instance, the contents of cell A4 and B4 are deleted when you set the Number of Rows to 3. Units You can choose a Unit Set for the Spreadsheet. All values in the Spreadsheet appear using units from the set you have chosen. Refer to Section 12.3.1 - Units Page in the HYSYS User Guide for more information about Unit Set.5-241 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-242 Spreadsheet ww ThExportable Cells Prior to explaining how the Exportable cells are created, the difference between exporting from the Spreadsheet (assigning a value from the Spreadsheet to a Process Variable) or importing from the Spreadsheet (accessing a Spreadsheet variable from another object) must be explained. Results that are exported from the Spreadsheet to a specifiable process variable can only be connected once. In other words, the same cell cannot be connected to two process variables. However, locations in the program which can import from the Spreadsheet (for example, PID Controller Cascade Source, Adjust Target Variable or Databook Variable) can access any cell, including those which are being exported to a flowsheet process variable. The Exportable Cells list has been created to allow objects which use the Variable Navigator to access variables associated with the Spreadsheet. The Exportable Cells group displays all cells which can be exported (including those which have been exported). The Visible Name, Variable Name, and Variable Type either displays the information you have specified for the associated cell on the Spreadsheet itself, or contains the information appropriate to Figure 5.1575-242 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-243 ww Ththe process variable that the cell has been exported to. In the former case, this information is modifiable; you can change it here or on the Spreadsheet itself. In the latter, you cannot modify the information as it is set by the process variable the cell has been exported to. For instance, if you export a Spreadsheet value to the Separator Valve Opening cell, the Variable Name and Variable Type are Valve Opening and Percent, respectively. You can edit the Variable Name and Variable Type for all non- exported variables that appear in the list The Visible Name and Variable Name columns display variables which can be exported. The fact that a variable appears in this list does not necessarily mean that the variable has been exported. When you access the Spreadsheet as the Object (for example, through the Variable Navigator), the contents of the Visible Name cell appear in the Variable List. Figure 5.158 There are three variables in the Variable List for SPRDSHT-1 corresponding to cells A1, B3, and B6. Notice that the Variable Names were added manually. When you use the Variable Navigator and select SPRDSHT-1 as the Object you see cells A1, B3, B6, A4, C5, and D4 in the Variable List.5-243 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-244 Spreadsheet ww ThFormulas Tab The Formulas tab displays a summary of all the formulas included in your spreadsheet. The table lists the name of the cell the formula is located in, the formula and the result of the formula. Spreadsheet Tab The Spreadsheet tab, with the labelled rows and columns, is similar to conventional Spreadsheets. From this tab, you can import and export variables, disconnect imports/exports, view associated object property views, define formula expressions, and modify variable names. Spreadsheet variables attached to the Controller, Adjusts, and Databook are not exported, but are imported from that Object. Figure 5.1595-244 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-245 ww ThCurrent Cell Group The Current Cell group displays information specific to the contents of the highlighted cell. For all cases, the Current Cell location appears. Cell containing a Formula or non-imported specifiable value The Variable Type and Variable Name are shown. You can choose a new Variable Type from the drop-down list, and you can edit the Variable name. Cells containing a formula or a non-imported specifiable value are automatically added to the Variable list on the Parameters tab; the Exportable checkbox is selected. Spreadsheet Function For More Information Importing and Exporting See sections: • Importing and Exporting Variables by dragging • Importing Variables by Browsing Associated Object Views Refer to section View Associated Object. Formula Expressions Refer to Section 5.10.2 - Spreadsheet Functions. Variable Names Refer to section Exportable Cells. Figure 5.160 The Variable Type sets the units for the Spreadsheet cell. For example, the SI units for Variable Type Area are m2.5-245 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-246 Spreadsheet ww ThCell containing an Export The object and variable to which the contents of the cell were exported are shown. The Exportable checkbox is selected in this case. You cannot change the Variable Name, since it is a HYSYS default. Cell containing an Import The object and variable from which the contents of the current cell were imported are shown. You cannot change the Variable name, since it is a HYSYS default. Calculation Order Tab The Calculation Order tab allows you to set the calculation level of each of the cells in the spreadsheet. Click the Calculation Order Help button to view the rules for setting the calculation levels. Figure 5.161 Figure 5.162 Figure 5.1635-246 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-247 ww ThUser Variables Tab The User Variables tab enables you to create and implement your own user variables for the current operation. Function Help and Spreadsheet Only buttons Clicking the Function Help button allows you to view the available Spreadsheet Functions and Expressions. Notice that this Help Window has three tabs: • Mathematical Expressions • Logical Expressions • Mathematical Functions Click the Spreadsheet Only button to view just the Spreadsheet cells in a separate window. This feature is useful when you have completely set up the Spreadsheet, and you only want to view the cell results. 5.11 Stream Cutter The stream cutter is an object that allows you to switch the fluid package of a stream anywhere in the flowsheet. This concept of changing fluid package is called fluid package transition. HYSYS automatically adds a stream cutter operation in between two objects on the PFD property view, where a switch in fluid package occurs. For more information refer to Section 1.3.8 - User Variables Page/ Tab. Refer to Section 5.10.2 - Spreadsheet Functions for more information.5-247 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-248 Stream Cutter ww Th5.11.1 Stream Cutter Property View To add a Stream Cutter to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Logicals radio button. 3. From the list of available unit operations, select Stream Cutter. 4. Click the Add button. The Stream Cutter property view appears. The Stream Cutter property view contains the following tabs: • Design • Transitions • Worksheet Figure 5.1645-248 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-249 ww ThChanging Fluid Package Currently, there are several methods for you to change the fluid package of objects: • using a drop-down list from the unit operation property view. • right-clicking on a selected group of operations in the PFD property view. • changing the flowsheet fluid package in the basis environment. If you add an operation and change its fluid package before any streams are connected to the operation, then connect empty streams (default fluid package, not connected to anything and empty composition) to the operation, HYSYS changes the empty stream’s fluid package to the operation’s fluid package. If a stream connected to an operation with a specified fluid package has one of the following: • a specified fluid package. • a connection to another operation. • its composition specified. HYSYS adds a stream cutter between the stream and the operation the stream is attached to. HYSYS does not allow fluid package transitions in electrolytic flow sheets or inside of column flow sheets. Fluid package transitions are allowed only in standard flow sheets. It is recommended to have all the fluid package specifications in place before switching to dynamics.5-249 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-250 Stream Cutter ww ThChanging the Fluid Package in the Unit Operation Property View You can change the fluid package of an operation using the Fluid Package drop-down list on the Connections page of the Design tab for the Operation property view. In this method, HYSYS propagates the new fluid package specifications to connected operations and streams. This propagation stops when it encounters one of the following: • a fluid package (either on an operation or stream) that you have already specified. • an operation with more than one feed or product. • a template or column. • an existing stream cutter. For example, consider a separator with its liquid stream connected to a pump, which is in turn connected to a valve. All objects are using FP1, the default for the flowsheet. If you specify the fluid package of the valve to FP2, HYSYS first propagates downstream. HYSYS finds a single stream, 5, with a fluid package at default status, which is FP1. So HYSYS calculates and changes stream 5 to the FP2 fluid package setting. You can change the fluid package of a stream on the Stream property view - Worksheet tab - Conditions page. Figure 5.1655-250 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-251 ww ThNext HYSYS propagates upstreams. The stream 4 also has a default fluid package setting. So HYSYS calculates, changing stream 4 to FP2 setting. The propagation goes along stream 4 until it encounters the pump. The pump has a default fluid package setting, and only a single inlet and a single outlet (energy streams are not considered because they have no dependence on fluid package). HYSYS calculates and changes the pump fluid package setting to FP2. The propagation continues to the pump’s inlet stream 3. The stream has a default fluid package setting of FP1, so HYSYS calculates and moves upstream to the separator. The separator has multiple outlet streams. So when HYSYS encounters the separator the propagation function stops, and HYSYS adds a cutter. Since the propagate calculation has already calculated stream 3 with fluid package FP2, HYSYS generates another stream called 3- with FP1 as the fluid package, and renames stream 3 to 3+, which has FP2 as the fluid package. At the point where the propagation stopped, a stream cutter is automatically added to the flowsheet between the operations in question, and a fluid package transition is added to the cutter’s transition collection. This fluid package transition automatically chooses its component mappers to be the default mapper of the The propagation calculation basically steps along. The valve calculates into stream 4, stream 4 calculates into the pump, the pump calculates into stream 3, and so forth. Figure 5.1665-251 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-252 Stream Cutter ww Thappropriate map collection. The default mapper can be changed by entering the Basis environment, opening the Simulation Basis Manager property view, and selecting the Component Maps tab. The fluid package transition function, however, does not automatically choose a transfer basis. You must make this decision. The status window should have a missing required info error for the stream cutter stating Transitions not ready. By double-clicking the statement in the status window, the stream cutter property view opens already on the Fluid Pkg page of the Transitions tab. In addition to automatically adding stream cutters where transitions between fluid packages are occurring, HYSYS can determine when stream cutters are no longer needed and prompts you to decide if they should be removed. For instance, continuing on from the previous example, change the pump’s fluid package back to FP1. Figure 5.167 Figure 5.168 Refer to the Fluid Pkg Page section for more information.5-252 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-253 ww ThFirst consider the downstream propagation. This propagation goes through the pump outlet stream 4 and finds the valve. Since this is where you made your first fluid package specification, the status of the fluid package is specified and propagation stops, and a stream cutter is automatically added (again the fluid package transition requires a transfer basis). Now consider the upstream propagation. The FP1 setting propagates through the inlet of the pump and encounters the stream cutter along stream 3+. The propagation stops according to the rules. This stream cutter contains the fluid package transition between FP1 and FP2, but now both sides are FP1. Since you have not added any other transitions to the stream cutter, the stream cutter only contains a fluid package transition. This fact combined with the fact that each side of the cutter has the same fluid package, HYSYS can assume the stream cutter is no longer needed. A property view appears at this point listing all unnecessary stream cutters, and you can select which ones, if any, to delete. Figure 5.169 Figure 5.170 Select or clear the checkbox in the Delete column to remove or keep the stream cutters. Click the Continue button to remove the selected stream cutters.5-253 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-254 Stream Cutter ww ThChanging the Fluid Package Using the Object Inspect Menu In order to bypass the propagation rules used by the unit operation property view method, you can change the fluid package of only certain operations of your choice. Select the operations you want from the PFD (like you would for copy/ paste), then right-click to open the object inspect menu. Select the Change Fluid Package command from the menu, and the Change Fluid Pkg property view appears. Using the drop-down list, you can select the fluid package you want for the selected objects. Consider the separator-pump-valve train defined in the previous section. By the end, you were left with the separator and pump using FP1 and the valve using FP2, with a cutter between the pump and valve. At this state, the flowsheet contains two individual fluid package specifications, one on the valve and the other on the pump. Depending on the flowsheet configuration and the type of Figure 5.171 Figure 5.172 You can select the transfer basis using the radio buttons in the Transfer Basis for Cutters group.5-254 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-255 ww Thoperations involved, it is important to note that by using the unit operation property view method you could end up with a less-than-desirable flowsheet with stream cutters where you didn’t want them. These hassles can be avoided by using object inspect, and the same result achieved in the previous section with two specifications can be achieved with one. To achieve the results in the above figure using only one specification, you use the object inspect menu. First select the valve and attached streams on the PFD. Then right-click to bring up the object inspect menu, and select the Change Fluid Pkg command. The Change Fluid Pkg property view appears. Select FP2 from the drop-down list, and a transfer basis from the radio button. Propagation is suppressed, so only streams 4 and 5 and the valve is switched to FP2 fluid package. A stream cutter is also added with default maps and the selected transfer basis between valve inlet stream 4 and the pump outlet stream 4. If you use the object inspect method to change fluid packages, and you happen to have a heat exchanger or LNG selected, all exchange sides of the exchanger in question get switched. There is no way of picking and choosing particular exchanger sides, except from the actual exchanger and LNG property views. Changing the Fluid Package from the Basis Environment You can change the fluid package of the default fluid package setting in the Basis environment. Open to the Simulation Basis Management property view, and click on the Fluid Pkgs tab. Select a different fluid package using the Default Fluid Pkg drop- down list. Notice that when you change the default fluid package setting, only objects whose fluid packages are still at default setting get switched to the new fluid package default. Refer to Section 2.2 - Fluid Packages Tab in the HYSYS Simulation Basis guide for more information.5-255 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-256 Stream Cutter ww Th5.11.2 Design Tab The Design tab contains the following pages: • Connections • User Variables • Notes Connections Page You can select the inlet and outlet streams of the stream cutter on this page. You can change the name of the stream cutter in the Name field. You can click on the Remove Cutter button to uncut the attached streams. The Remove Cutter button is available only after a stream has been specified in both the inlet field and outlet field. Figure 5.173 The difference between the Remove Cutter button and Delete button is that the Remove Cutter button maintains upstream and downstream connections.5-256 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-257 ww ThUser Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor, where you can record any comments or information regarding the operation or to your simulation case in general. 5.11.3 Transitions Tab The Transitions tab contains the following pages: • Transitions • Fluid Pkg The Fluid Pkg page is available only after you add the option into the Transitions page, as shown in the figure below. The Fluid Pkg page is automatically available, if the stream cutter was generated by HYSYS to perform fluid package transition. Figure 5.174 For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.5-257 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-258 Stream Cutter ww ThTransitions Page The Transitions page contains a table and three buttons: Add, View, and Remove. When no transition type has been selected, only the Add button is available for use, and the table is blank as shown in the figure below. Adding a Transition Click the Add button to open the Select Transition property view. From this property view you can add the transition type you want the stream cutter to perform. Currently there is only one transition type available: fluid package. Figure 5.175 Figure 5.176 Select the transition type you want from the list, and click the Add button. Click the Close button to close the property view when you are done.5-258 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-259 ww ThOnce you have selected a transition type and return to the transition page, the View and Remove buttons are available for use. Viewing a Transition Select a transition type from the list, and click the View button to open a property view that contains more detailed information about the transition type and its functions. The figure below shows a fluid package transition property view. The Fluid Package Transition property view consists of the following objects: Figure 5.177 Depending on how the stream cutter is added and how the transition type is defined, the field texts can be black to indicate non-changeable values, or blue to indicate changeable values. Object Description Inlet Stream Field Displays the name of the stream going into the stream cutter. Inlet Fluid Pkg Field Displays the fluid package being used by the inlet stream. Outlet Stream Field Displays the name of the stream coming out of the stream cutter.5-259 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-260 Stream Cutter ww ThOutlet Fluid Pkg Field Displays the fluid package being used by the outlet stream. Forward Component Map Group Lists the component maps that are used if composition is passed from the inlet stream to the outlet stream. • Click the Add button to add another component map. • Click the View button to open the Component Map property view, that contains more information regarding the selected component map. • Click the Delete button to delete the selected component map. You cannot delete the default component map. The list does not affect the simulation, only the selected map does. The map determines how components are mapped across. The maps are necessary only when dealing with component lists that are different. The maps tell HYSYS how to transfer the compositions. Backward Component Map Group Lists the component maps that are used if composition is passed from the outlet stream to the inlet stream. • Click the Add button to add another component map. • Click the View button to open the Component Map property view, that contains more information regarding the selected component map. • Click the Delete button to delete the selected component map. You cannot delete the default component map. A component map is necessary when, you have a fluid package FP7 with seven components and another fluid package FP6 with six components. HYSYS cannot just pass the mole fractions of the seven components to the other fluid package, because there are only six slots to put the information in. The component map tells HYSYS how to transfer the mole fraction values. Transfer Basis Group Contains six transfer basis types available for the fluid package transition tool. You must select one of the transfer basis radio button.The transfer basis types are: • T-P Flash. Transfers temperature or pressure. • P-H Flash. Transfers pressure and enthalpy • VF-T Flash. Transfers vapour fraction and temperature. • VF-P Flash. Transfers vapour fraction and pressure. • None Required. Select this radio button when there is no need for a transfer basis. Use this transfer only for energy streams. • None Set. This is the default setting. Stream cutter does not solve if the radio button is selected. Object Description Refer to Section 6.3 - Component Map Property View in the HYSYS Simulation Basis guide for more information about the Component Map property view. Refer to Section 6.3 - Component Map Property View in the HYSYS Simulation Basis guide for more information about the Component Map property view.5-260 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-261 ww ThRemoving a Transition Select the transition type you want to remove from the table, and click the Remove button. If the transition type is currently being used in the stream cutter, the Remove button automatically becomes unavailable when you select the transition from the table. When you remove a transition from the table, the page associated with the transition is also removed from the Transition tab. Activate a Transition Select the checkbox in the Active column to activate the associated transition type. Clearing the checkbox associated with the transition type, deactivates the transition but does not remove the transition from the table. Active Checkbox This checkbox is the same checkbox from the table on the Transitions page. You can select or clear this checkbox to activate or deactivate the transition. When the Active checkbox changes in this property view, the changes also occur in the table on the Transitions page. Imbalance Button Click this button to open the Imbalance Info property view. The Imbalance Info property view displays any mole, mass, or liquid volume imbalance that can occur when switching fluid package. The property view is pertinent for fluid package transition involving two different components list. Figure 5.178 Object Description Imbalance Info property view The selected transition is Fluid Pkg, which is also the transition being used in the stream cutter. So the Remove button is disabled.5-261 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-262 Stream Cutter ww ThFluid Pkg Page The Fluid Pkg page contains information about the fluid package transition. You can also change the transfer basis on this page. The following table lists and describes the objects on this page. Figure 5.179 Depending on how the stream cutter is added and how the transition type is defined, the field texts can be black to indicate non-changeable values, or blue to indicate changeable values. Object Description Inlet Fluid Pkg Field Displays the fluid package being used by the inlet stream. Outlet Fluid Pkg Field Displays the fluid package being used by the outlet stream.5-262 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-263 ww ThForward Maps Group Lists the component maps that are used if composition is passed from the inlet stream to the outlet stream. • Click the Add button to add another component map. • Click the View button to open the Component Map property view, that contains more information regarding the selected component map. • Click the Delete button to delete the selected component map. You cannot delete the default component map. The list does not affect the simulation, only the selected map does. The map determines how components are mapped across. The maps are necessary only when dealing with component lists that are different. The maps tell HYSYS how to transfer the compositions. Backward Maps Group Lists the component maps that are used if composition is passed from the outlet stream to the inlet stream. • Click the Add button to add another component map. • Click the View button to open the Component Map property view, that contains more information regarding the selected component map. • Click the Delete button to delete the selected component map. You cannot delete the default component map. A component map is necessary when, you have a fluid package FP7 with seven components and another fluid package FP6 with six components. HYSYS cannot just pass the mole fractions of the seven components to the other fluid package, because there are only six slots to put the information in. The component map tells HYSYS how to transfer the mole fraction values. Transfer Basis Group Contains six transfer basis types available for the fluid package transition tool. You must select one of the transfer basis radio button.The transfer basis types are: • T-P Flash. Transfers temperature or pressure. • P-H Flash. Transfers pressure and enthalpy • VF-T Flash. Transfers vapour fraction and temperature. • VF-P Flash. Transfers vapour fraction and pressure. • None Required. Select this radio button when there is no need for a transfer basis. Use this transfer only for energy streams. • None Set. This is the default setting. Stream cutter does not solve if the radio button is selected. Object Description Refer to Section 6.3 - Component Map Property View in the HYSYS Simulation Basis guide for more information about the Component Map property view. Refer to Section 6.3 - Component Map Property View in the HYSYS Simulation Basis guide for more information about the Component Map property view.5-263 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-264 Transfer Function ww Th5.11.4 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. The PF Specs page is relevant to Dynamics cases only. 5.12 Transfer Function The Transfer Function block is a logical operation which takes a specified input, and applies the chosen transfer function to produce an output. A typical use of the Transfer Function is to apply disturbances to a process, such as varying the temperature of a feed stream without having to add a disturbance manually. It is also useful to simulate a unit for which you know the response characteristics (gain, damping factor, period) but not the actual equations involved. The following Transfer Functions are available: • First & second order lead • First & second order lag • Second order lag / sine wave • Delay • Integrator • Ramp • Rate Limiter The second order lag can be defined either as a series of two first-order lags, or as a single explicit second order lag. Active Checkbox This checkbox is the same checkbox from the table on the Transitions page. You can select or clear this checkbox to activate or deactivate the transition. When the Active checkbox changes in this property view, the changes also occur in the table on the Transitions page. View Button Click this button to open the transition type property view. Object Description Refer to the section on Viewing a Transition for more information. Refer to Section 1.3.10 - Worksheet Tab for more information.5-264 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-265 ww ThCombinations of the above functions may be used to produce the desired output. The combined transfer function is as follows: The input X(s) is multiplied by the transfer function to obtain the output. Notice that the input (or Process Variable Source) is optional; you can use a fixed value as the input. The transfer function is defined here in the Laplace Domain (using the Laplace Variables). When in the Laplace Domain, the overall transfer function is simply the product of the individual transfer functions. The Laplace Transfer Function must be converted to a real-time function in order to be meaningful for a dynamic simulation. For instance, the Laplace Transform for the sine function is: When converted to the time domain by taking the inverse Laplace, we obtain: (5.33) (5.34) (5.35) (5.36) G s( ) Lead1 s( )Lead2 s( )Lag1 s( )Lag2 s( )W s( )D s( )R s( )= Y s( ) G s( )X s( )= G ω s2 ω2+ -----------------= f t( ) ωtsin=5-265 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-266 Transfer Function ww Th5.12.1 Transfer Function Property View There are two ways that you can add a Transfer Function to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Logicals radio button. 3. From the list of available unit operations, select Transfer Function Block. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the Transfer Function icon. The Transfer Function property view appears. Figure 5.180 Transfer Function icon Click the Face Plate button to access the Transfer Function face plate property view. Select the G(s)Enabled checkbox to combine more than one specified functions in the Parameters tab.5-266 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-267 ww Th5.12.2 Connections Tab The following information is shown on the Connections tab: You can click the Equation Help button to view the Transfer Function equations. 5.12.3 Parameters Tab The Parameters tab allows you to define the entire transfer function G(s), by defining the integrator, delay, lag, lead, and 2nd order transfer functions. The Parameters tab contains the following pages: • Configuration • Integrator • Delay • Lag • Lead • 2nd Order • Ramp • Rate Limiter The last seven pages allow you to define the different transfer function terms. Each of these pages contains the Active Transfer Function group, which consists of a number of checkboxes corresponding to the available components of the Transfer Function. By selecting the appropriate checkbox, you can include that term in the overall Transfer Function. When you activate individual functions on the Integrator/Delay/Lag/Lead/ Input Required Description Name The name of the Transfer Function Block. Process Variable Source A stream or operation. You can select the PV Object and Variable by clicking the Select PV button. The Process Variable is optional. If you do not specify a PV, enter a constant PV on the Parameters tab. Transformed PV Target Object A stream or operation. Select the PV Object and Variable by clicking the Select PV’ button. The PV Target is not required to have the same variable type as the PV Source. Refer to Section 1.3.9 - Variable Navigator Property View for more information.5-267 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-268 Transfer Function ww Th2nd Order/Ramp/Rate Limiter pages, the appropriate checkboxes are then selected in this group. Configuration Page The Configuration page allows you to define the Process and Output Variable limits. Figure 5.181 Figure 5.1825-268 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-269 ww ThThe Operational Parameters group contains the following parameters: Selecting the Reset out of range PV value using the specified range checkbox tells HYSYS to reset the PV input value whenever the PV value deviates outside the specified range. The specified range can be entered in the Ranges group. The reset value is the value entered in the PV field from the Operational Parameters group. The Ranges group contains the following parameters: Parameter Description PV The value of the PV input (Process Variable or constant PV) is shown in this field. • If you did not define a PV source in the Connections tab, then you must specify a constant PV value in this field. Notice the text is blue in colour, indicating you can change this value. • If you defined a PV source on the Connections tab, then this field displays the PV Input. Notice the text is black in colour, indicating it is a HYSYS calculated value. OP Displays the calculated value of the PV Output. Output Variable Type Displays the OP variable type. The Reset out of range PV value using the specified range checkbox is not available if a PV source is defined on the Connections tab. Parameter Description PV Minimum and Maximum Enter the percent range of the Transfer Function Input. These percent values define the range of the input value; regardless of the varying input value from the source or Transfer Function parameters, the input value always stays in this range. This percent range affects the Noise and sine wave amplitude. OP Minimum and Maximum Enter the range of the Transfer Function Output. These values define the range of the output; regardless of the input or Transfer Function parameters, the output always stays in this range. This range affects the Noise and sine wave amplitude.5-269 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-270 Transfer Function ww ThThe Noise group contains the following parameters: Integrator Page The Integrator page consists of the Active Transfer Function group and Integrator Parameters group. The Integrator Transfer Function requires only one parameter, the T (Integrator Period) located in the Integrator Parameters group: The unit step response of the Integrator Transfer Function is Parameter Description PV (Std Dev %) Enter the Standard Deviation of the input noise as a percentage of the PV Range. OP (Std Dev %) Enter the Standard Deviation of the output noise as a percentage of the PV Range. The noise follows a normal distribution. Figure 5.183 (5.37) (5.38) You can change the integrator period value in this field. G 1 Ts -----= f t( ) t T --=5-270 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-271 ww ThDelay Page The Delay Page consists of the Active Transfer Function group and Delay Parameters group. The Delay Parameters group contains of two input fields the K (Gain) and T (Delay Period) that are two parameters of the Delay Equation. The Delay Equation is defined as: where: to = dead time The inverse Laplace Transform of the Delay Equation multiplied by the general function F(s) is equal to Kf(t-to). This is shown below: Figure 5.184 (5.39) (5.40) G Ke tos– = L 1– Ke tos– F s( )( ) Kf t to–( )=5-271 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-272 Transfer Function ww ThDelay can be used in combination with the other Transfer function terms, by selecting the Delay checkbox in the Active Transfer Function group. Lag Page The Lag page allows you to simulate the response of a first- order or second-order lag. A second order lag can be defined on the Lag page creating two first-order lags. The Lag page contains the Lag 1 Parameters group and Lag 2 Parameters group; with each group defining a single-order lag transfer function. The group contains two fields the K (Gain) and T (Time Constant). The Lag Equation is defined as follows: Figure 5.185 (5.41)G K Ts 1+ --------------=5-272 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-273 ww Thwhere: G = transfer function K = gain T = time constant (t) s = Laplace Transform variable The time constant is the time required for the response to reach 63.2% of its final value. The unit step response of the Lag Equation is: Lead Page The Lead page allows you to define either a first or second order Lead transfer function. This is done via the two groups the Lead 1 Parameters group and Lead 2 Parameters group. Both groups allow for the definition of the two terms of the Lead Equation K (5.42) A second-order Lag may also be defined on the 2nd Order page. This second-order Lag is defined using variables K, T, and . K 1 e– t T --– ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ Refer to the section on the 2nd Order Page for more information. ξ 5-273 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-274 Transfer Function ww Thand T. The Lead Equation is defined as: where: K = gain T = time constant The Inverse Laplace Transform of the Lead Equation multiplied by the general function F(s) is: A first or second-order Lead can be simulated by making one or both Lead Parameters active. You can make a set of K and T active by selecting the Lead checkbox in the Active Transfer Figure 5.186 (5.43) (5.44) G K Ts 1+( )= L 1– K Ts 1+( )F s( )[ ] K df t( ) dt -----------T f t( )+=5-274 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-275 ww ThFunctions group. The response is an exponential curve of the following form: where: K = process gain T = time constant The time constant is the time required for the response to reach 63.2% of its final value. In this case, the time constant is 600s (10 minutes), so the response should have a value of about 63 kgmole/h 10 minutes after the step change in Input is introduced. This is illustrated in the Strip Chart. (5.45)Flow t( ) K 1 e t T --– – ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ = 5-275 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-276 Transfer Function ww Th2nd Order Page The 2nd Order page allows you to define either the second order or sine wave function. Standard Second Order Select the Lag radio button in the 2nd Order Functionality Selection group, which is used to simulate the response of a standard Second Order process. The Second Order Lag is defined as: where: = damping factor (or damping ratio) The form of the Inverse Laplace Transform of this function depends on whether the Damping factor is less than, equal to, or greater than one. The Inverse Laplace Transform is relatively complex and is not shown here. Figure 5.187 (5.46)G K T 2s2 2Tξs 1+ + --------------------------------------= ξ ξ 5-276 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-277 ww ThA standard second-order Lead or Lag transfer function may or may not produce an oscillatory output, depending on the damping factor (“Xi”). If the damping factor is unity, the response is said to be critically damped. If >1, the process is overdamped, producing a slower response than the critically damped case. If <1, the process is underdamped, producing the faster response. However, the response overshoots the target value, and oscillates with a period T. Select the 2nd Order checkbox to simulate the Second Order Process. Sine Wave The Sine Wave Transfer function is defined as follows: where: = frequency of oscillation First Order, Delay, and Ramp Functions can also be active, in which case all equations are superimposed. Figure 5.188 (5.47) ξ ξ ξ G Kω s2 ω2+ -----------------= ω 5-277 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-278 Transfer Function ww ThK = amplitude The frequency is the inverse of the period ( = 1/T). The Inverse Laplace of the Sine Wave Transfer Function is: The K-value (transfer function gain) is the amplitude of the sine wave, in a percentage of the Signal range. The range is the difference between the Signal Minimum and Maximum values given on the Configuration page. As usual, select the Sine Wave radio button on the 2nd Order page to simulate the Sine Wave. You cannot activate both the Standard 2nd Order and the Sine Wave at the same time. Ramp Page The Ramp Page allows you to ramp the output value (OP) linearly in a transfer function. (5.48) Figure 5.189 ω f t( ) K ωtsin=5-278 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-279 ww ThThe Ramp Parameters group contains the following parameters: • Ramp Magnitude. Allows you to specify the amount of ramp either as a magnitude in the OP units, or as a percentage of the OP range. A positive ramp magnitude represents an increase in signal, whereas a negative value represents a decrease in signal. • Ramp Duration. Allows you to specify the total amount of time required for the ramp function to change the OP. • Current Offset. Displays the amount of deviation between the original OP, and the ramped OP. You can execute the Ramp by clicking on the Start Ramp button. The status of the ramp is shown in the ramp status bar. Once the ramp is running, the Start Ramp button automatically changes to a Stop Ramp button. You can stop the ramp at any given time by clicking on the Stop Ramp button. As the ramp is executing, the Ramp Magnitude, and Ramp Duration start approaching to zero. When the Ramp Duration reaches zero, the ramp stops. You can reset the OP to the original value (before ramped) by clicking on the Reset Ramp button. Rate Limiter Page The Rate Limiter page allows you to specify the maximum rate of change of the OP. Figure 5.190 Ramp status bar5-279 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-280 Transfer Function ww ThThe Rate Limiter analyzes the signal transformation in the transfer function, and limits the OP to change by a user- specified maximum. The OP is restricted to change faster than the preset maximum. Therefore, any abrupt changes in the input signals can be intercepted, and smoothed. To set the maximum rate of change of the OP, you can specify one of the following parameters in the Rate Limiter Parameters group: • Max Rate of Change (/min). Allows you to specify the magnitude of the maximum rate of change in the OP units. • Max Rate of Change (%/min). Allows you to specify the percentage of the maximum rate of change in the OP range. 5.12.4 Stripchart Tab The Stripchart tab allows you to select and create default strip charts containing various variable associated to the operation. 5.12.5 User Variables Tab The User Variables tab enables you to create and implement your own user variables for the current operation. Refer to Section 1.3.7 - Stripchart Page/Tab for more information. For more information refer to Section 1.3.8 - User Variables Page/ Tab.5-280 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-281 ww Th5.13 Common Options 5.13.1 ATV Tuning Technique The ATV (Auto Tune Variation) Technique is one of a number of techniques used to determine two important system constants known as the Ultimate Period, and the Ultimate Gain. From these constants, tuning values for proportional, integral, and derivative gains can be determined. A small limit-cycle disturbance is set up between the Control Output and the Controlled Variable, such that whenever the process variable crosses the set point, the controller output is changed. The ATV Tuning Method is as follows: • Determine a reasonable value for the valve change (OP). Let h represent this value. In HYSYS, h is 5%. • Move the valve +h%. • Wait until the process variable starts moving, then move valve -2h%. • When the PV crosses the set point, move the OP +2h%. • Continue this procedure until the limit-cycle is established. From the cycle, two key parameters can be observed: The Tuning option only sets up the limit cycle; it does not calculate the tuning parameters for you. To set up a Strip Chart to track the PV and OP do the following: 1. To open the Databook property view, press CTRL D. 2. On the Variables tab, add the PV and OP to the Variable List. 3. On the Strip Charts tab, add a Strip Chart and activate the PV and OP. 4. View the Strip Chart. Observed Parameter Description Amplitude (a) The amplitude of the PV curve, as a fraction of the PV span. Ultimate Period (PU) Peak-to-Peak period of the PV curve.5-281 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-282 Common Options ww ThThe Ultimate Gain can be calculated from the following relationship: where: KU = ultimate gain h = change in OP (0.05) a = amplitude Finally, the Controller Gain and Integral Time can be calculated as follows: Controller Gain = KU / 3.2 Controller Integral Time = 2.2*PU 5.13.2 Controller Face Plate There are two ways that you can access the controller Face Plate: 1. In the menu bar select Tools | Face Plates command, or press CTRL F. The Face Plates property view appears. 2. From the list of available flowsheets, select the flowsheet that contains the logical operation you want to view the face plate for. 3. From the list of available logical operations, select the logical operation you want to view the face plate for. 4. Click the Open button. The Face Plates property view closes and the face plate for the selected logical operation appears. OR (5.49) The ATV Tuning Method only works for systems with dead time. KU 4h πa -----= Refer to Section 11.8 - Face Plates in the HYSYS User Guide for more information.5-282 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-283 ww Th1. Open the property view of a Controller operation. 2. Click the Face Plate button located at the bottom of the Controller’s property view. Each controller’s Face Plate varies in appearance, however the functionality remains the same. This section provides a general description of how to use the controller Face Plate. The Face Plate provides all pertinent information about the controller when the simulation is running. The Setpoint is shown as a red pointer, and the actual value of the Process Variable appears in the current default unit. Output is always displayed as a percentage of the span you defined on the Valve tab. The Face Plate also displays the execution type and the setpoint source. Also, you can change the mode of the Controller by selecting the mode from the drop-down list at the bottom left of the Face Plate. The mode choices are identical to those on the Parameters tab. Clicking the Tuning button returns you to the Tuning tab of the Controller property view. Figure 5.191 Click the Parameters button to return to Parameters tab of the Ratio/Split Range Control property view. The drop-down list contains three controller mode options: Off, Manual, and Automatic. Click the up and down arrows to access the first and second variables. The execution type is shown as either Int (Internal) or Ext (external). The setpoint is shown as either L (local) or R (Remote). Setpoint The shaded bar indicates the value of the Process Variable/Controller Output in a percentage of the PV/OP range, and the number is the actual PV/OP.5-283 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-284 Common Options ww ThChanging the Setpoint and Output You can change the SP or OP of the Controller (depending on the current mode) at any time during the simulation without returning to the Parameters tab, by using the Face Plate. To change the SP while in Automatic mode, or to change the OP while in Manual mode, use any one of the following three methods: 1. Move to the field for the parameter you want to change. For this example, the Setpoint (top field) is changed. Start entering a new value for the SP, and HYSYS displays a field with a drop-down list containing the default units. Once you have entered the value, press ENTER and HYSYS accepts the new Setpoint. Figure 5.192 Figure 5.193 Setpoint This shaded bar and number indicate the value of the Controller Output (valve opening) in percent.Select this button to return to the Controller Tuning property view. The shaded bar indicates the value of the Process Variable in a percentage of the PV range, and the number is the actual PV. The current Controller mode. The execution type is shown as either Int (Internal) or Ext (external). The setpoint is shown as either L (local) or R (Remote).5-284 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Logical Operations 5-285 ww Th2. Place the mouse pointer near the red Setpoint indicator, and the cursor changes to a double-ended arrow. Click and hold, a fly-by appears below, showing the current value of the SP (in this case, 50%). 3. Click and drag the double-ended arrow to the new SP of 60%. The fly-by displays the SP value as you drag. Release the mouse button to accept the new SP. 4. Place the pointer at either end of the field, and the pointer changes to a single-ended arrow. Click once to increase or decrease the value by 1%. For example, switch to Manual mode and adjust the OP. To increase the OP, move the pointer to the right end of the field and the single-ended arrow pointing to the right appears. Click to increase the OP by 1%. If you select an alternate unit, your value appears in the face plate using HYSYS display units. Figure 5.194 You can click the button consecutively to repeatedly increase (or decrease) the OP. Position the pointer near the SP indicator, and the double-ended arrow appears. Click and hold, a fly-by appears, showing the current value of the SP. Click and drag the arrow to the new SP location. The fly-by shows the SP as it changes. Release the mouse button and the SP indicator moves to the new SP.5-285 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 5-286 Common Options ww ThObject Inspect Menu of Face Plates The Object Inspect menu for a Fixed Size Face Plate is shown in the figure below. The options associated with this menu are: The additional menu options in the Object Inspection menu for a Scalable Face Plate are: Figure 5.195 Command Description Turn Off Turns the Controller Mode to Off. Start Ramp Starts Setpoint Ramping Auto-Tune Puts the Controller into a cycling mode. This can be used for tuning the Controller. Tuning Returns you to the Tuning page of the Controller property view. Connections Returns you to the Connections page of the Controller property view. Parameters Returns you to the Parameters page of the Controller property view. Print Datasheet Allows you to print the Datasheet for the controller. Print Specsheet Allows you to print the controller Specsheet. Command Description Font Allows you to choose the Font for the text on the Face Plate. Hide Values/ Show Values Hides the values for SP, PV, and OP. When the values are hidden, the Show Values option appears. Choose this to display the values. Hide Units/Show Units Hides the units for SP and PV. When the units are hidden, the Show Units option appears in the menu. Choose this to display the units. Refer to Chapter 3 - Control Theory in the HYSYS Dynamic Modeling guide for information on the object inspection options.5-286 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-1 ww Th6 Piping Operationsw.cadfamily.com EMa e document is for study 6.1 Compressible Gas Pipe................................................................... 1 6.1.1 Compressible Gas Pipe Property View.......................................... 5 6.1.2 Design Tab .............................................................................. 6 6.1.3 Rating Tab............................................................................... 9 6.1.4 Worksheet Tab ....................................................................... 11 6.1.5 Performance Tab .................................................................... 12 6.1.6 Properties Tab........................................................................ 13 6.1.7 Dynamics Tab ........................................................................ 14 6.2 Liquid-liquid Hydrocyclone........................................................... 16 6.2.1 Liquid-liquid Hydrocyclone Property View................................... 23 6.2.2 Design Tab ............................................................................ 24 6.2.3 Worksheet Tab ....................................................................... 30 6.2.5 Dynamics Tab ........................................................................ 34 6.2.6 Nomenclature ......................................................................... 34 6.3 Mixer............................................................................................. 35 6.3.1 Mixer Property View................................................................ 36 6.3.2 Design Tab ............................................................................ 37 6.3.3 Rating Tab............................................................................. 40 6.3.4 Worksheet Tab ....................................................................... 40 6.3.5 Dynamics Tab ........................................................................ 40 6.4 Pipe Segment............................................................................... 43 6.4.1 Pipe Segment Property View .................................................... 50 6.4.2 Design Tab ............................................................................ 51 6.4.3 Rating Tab............................................................................. 66 6.4.4 Worksheet Tab ....................................................................... 83 6.4.5 Performance Tab .................................................................... 83 6.4.6 Dynamics Tab ........................................................................ 896-1 il:cadserv21@hotmail.com only,if tort to your rights,please inform us,we will delete 6-2 Piping Operations www.cadfamily.com EMa The document is for study 6.4.7 Deposition Tab........................................................................92 6.4.8 Profes Wax Method..................................................................95 6.4.9 Modifying the Fittings Database ..............................................105 6.5 Relief Valve.................................................................................110 6.5.1 Relief Valve Property View......................................................110 6.5.2 Design Tab ...........................................................................111 6.5.3 Rating tab............................................................................114 6.5.4 Worksheet Tab......................................................................118 6.5.5 Dynamics Tab.......................................................................118 6.6 Tee .............................................................................................122 6.6.1 Tee Property View .................................................................123 6.6.2 Design Tab ...........................................................................124 6.6.3 Rating tab............................................................................127 6.6.4 Worksheet Tab......................................................................128 6.6.5 Dynamics Tab.......................................................................128 6.7 Valve ..........................................................................................131 6.7.1 Valve Property View ..............................................................133 6.7.2 Design Tab ...........................................................................134 6.7.3 Rating Tab............................................................................135 6.7.4 Worksheet Tab......................................................................147 6.7.5 Dynamics Tab.......................................................................147 6.8 References..................................................................................1586-2 il:cadserv21@hotmail.com only,if tort to your rights,please inform us,we will delete Piping Operations 6-3 ww Th6.1 Compressible Gas Pipe The Compressible Gas Pipe (CGP) model uses an algorithm that solves a vector system using the Two-Step Lax-Wendroff method with Boris & Book anti-diffusion. The CGP unit operation is primarily designed for transient calculations with streams. Steady state calculations have been implemented primarily for initialization of the Pipe State prior to transient calculations. The following calculation modes are supported in steady sate mode: • Specify Inlet Pressure, Temperature, and Mass Flow • Specify Inlet Temperature, Mass Flow, and Outlet Pressure • Specify Inlet Pressure and Temperature, and Outlet Pressure. Alternatively the pressure drop may be used with either boundary pressure. Model for a Single Phase Compressible Flow The following equations are used in HYSYS to model a single phase compressible flow. Governing Equations • Mass: (6.1)Aρ( )∂ t∂ -------------- Aρu( )∂ x∂ -----------------+ 0=6-3 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-4 Compressible Gas Pipe ww Th• Momentum: • Energy: where: A= , pipe cross-sectional area E = , total internal energy H = , total enthalpy S = , the pipe perimeter D = pipe diameter e = internal energy f = friction factor g = acceleration due to gravity h = enthalpy k = heat transfer coefficient p = pressure t = time T = temperature Twall = wall temperature (6.2) (6.3) ρu( )∂ t∂ ------------- ρu2 p+( )∂ x∂ -------------------------+ ρgsinθ 1 2 --fρu u S A --– ρu2 1 A ---dA dx ------–= ρE( )∂ t∂ -------------- ρHu( )∂ x∂ ------------------+ k Twall T–( )S A --- ρ– gsinθ 1 2 --fρu2 u S A ---– ρHu 1 A -- dA dx ------–= 1 4 --πD2 e 1 2 --u2+ h 1 2 --u2+ πD6-4 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-5 ww Thu = velocity x = distance = pipe inclination = density Algorithm The algorithm solves the vector system by the Two-Step Lax- Wendroff method with Boris & Book anti-diffusion. 6.1.1 Compressible Gas Pipe Property View There are two ways that you can add a Compressible Gas Pipe to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Piping Equipment radio button. 3. From the list of available unit operations, select Compressible Gas Pipe. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the Compressible Gas Pipe icon. (6.4) θ ρ U∂ t∂ ------ D∂ x∂ ------+ G= Compressible Gas Pipe icon6-5 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-6 Compressible Gas Pipe ww ThThe Compressible Gas Pipe property view appears. 6.1.2 Design Tab The Design tab contains the following pages: • Connections • Parameters • User Variables • Notes Figure 6.16-6 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-7 ww ThConnections Page On the Connections page, you must specify the Feed and Product material streams. You can specify the streams by either typing the name of the new stream or selecting existing streams in the Inlet and Outlet drop-down lists. You can also edit the name of the operation on this page. Figure 6.2 The Compressible Gas Pipe does not support an energy stream.6-7 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-8 Compressible Gas Pipe ww ThParameters Page The Parameters page allows you to specify the pressure drop across the pipe as well as the name of the operation. There are also three calculated values that are displayed on the page. • Max. Mach Number. For steady state calculations this is always at the outflow from the pipe. During dynamic calculations this can be at any location within the pipe. • Max. Pressure. For steady state calculations this is always at the outflow from the pipe. During dynamic calculations this can be at any location within the pipe. • Max. Velocity. For steady state calculations this is always at the outflow from the pipe. During dynamic calculations this can be at any location within the pipe. User Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. Figure 6.3 For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.6-8 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-9 ww Th6.1.3 Rating Tab The Rating tab consists of two pages: • Sizing. you provide information regarding the dimensions of sections in the pipe segment • Heat Transfer. the heat loss of the pipe segment can either be specified or calculated from various heat transfer parameters. Sizing Page On the Sizing page, the length-elevation profile for the CGP is constructed. You can provide details for each fitting or pipe section that is contained in the CGP that you are modeling. An unlimited number of pipe sections or fittings can be added on this page. For a given length of pipe which is modelled in HYSYS, the parameters of each section is entered separately. To fully define the pipe section, you must also specify pipe schedule, diameters (nominal or inner and outer), a material, and a number of cells. There are two ways that you can add sections to the length- elevation profile: • Click the Add Section button, which allows you to add the new section after the currently selected section. • Click the Insert Section button, which allows you to add the new section before the currently selected section Figure 6.46-9 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-10 Compressible Gas Pipe ww ThFor each segment that you add, you must specify the following: • Length. The physical length of the pipe. Notice that it is not appropriate to enter an equivalent length and attempt to model fittings. • Elevation Change. The elevation change of the pipe. • Cells. Number of cells within the pipe (10 - 1000). When modeling multiple sections, faster and more stable convergence can be obtained if all cell sizes are similar. For a stable solution, the number of cells should be selected such that the following constraint is met: To delete a section, click the section you want to delete and click the Delete button. The Clear Profile button deletes all sections except for the first section. However, all data for the first section is cleared. The Overall Dimensions group manages the pipe diameter and material data. This works in the same fashion as the standard Pipe Segment unit operation. (6.5) The cells have to be sufficiently small to ensure that in any one time step there will be changes of sufficient magnitude in a sufficient number of cells to ensure that the solver used by the Compressible Gas pipe and the HYSYS dynamics pressure-flow solver interact correctly. The external diameter is not currently used by the calculations. It has been added so that the heat transfer models can be more easily enhanced in future versions. Cell Length Time Step --------------------------- 0.5 Sonic Velocity< Refer to Section 7.3 - Pipe Segment for more information.6-10 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-11 ww ThHeat Transfer Page A simplified heat transfer model is used that allows you to specify the ambient temperature and an overall heat transfer coefficient. 6.1.4 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. Figure 6.5 The Ambient Temperature is the bulk ambient temperature, and Overall HTC is the overall heat transfer coefficient based upon the outside diameter of the pipe. The PF Specs page is relevant to dynamics cases only. Refer to Section 1.3.10 - Worksheet Tab for more information.6-11 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-12 Compressible Gas Pipe ww Th6.1.5 Performance Tab This tab is functionally similar to the Performance tab on the standard Pipe Segment unit operation. You can view a complete profile by clicking on the View Profile button. The properties displayed on the Table tab of the Profile property view are listed below: • Axial Length • Pressure • Temperature • Mass Flow • Velocity • Mach Number • Mass Density • Internal Energy • Enthalpy • Speed Of Sound Figure 6.6 Refer to Section 7.3 - Pipe Segment for more information.6-12 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-13 ww Th6.1.6 Properties Tab Due to the number of physical property calculations, an acceptable calculation speed is not possible by directly calling the current property package for the flowsheet. Three alternative methods are available from the drop-down list: • Perfect Gas • Compressible Gas • Table Interpolation The methods are described in the sections below. Perfect Gas Compressible Gas Same as for perfect gas, but The compressibility factor, Z is calculated from the current property package for the flow sheet at the average conditions within the pipe. Table Interpolation A neural network calculates physical properties. This neural network uses a Radial Basis Function to train the network from physical properties, predicted from the current property package of the flowsheet. (6.6) (6.7) (6.8) H Cp TΔ= ρ PMW RT -------------= ρ PMW ZRT -------------=6-13 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-14 Compressible Gas Pipe ww ThPrior to calculations, you must train the neural network. The Table Generation group manages the extent of the training. 6.1.7 Dynamics Tab The Dynamics tab contains the following pages: • Specs • StripChart Specs Page For transient compressible flow calculations, the solution of pressure/flow equations is inappropriate since the boundary pressure is not directly related to flow. It is however critical that the compressible gas solve simultaneously with the other flowsheet equations. This is achieved by making perturbations at each end of the pipe for each time step and re-evaluating the change in state over the time step. These changes are then fit to an equation of the following form, which is passed to the Pressure Flow solver: Figure 6.7 Care must be taken to train over the full extent of the expected range of operating conditions since extrapolation always yield unpredictable results. (6.9)A.Pres BFlow2 CFlow D+ + + 0=6-14 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-15 ww ThThe Pressure Flow Equations group displays the values for the coefficients in the above equation, which are continuously updated at each time step. Stripchart Page The Stripchart page allows you to select and create default strip charts containing various variable associated to the operation. Figure 6.8 Refer to Section 1.3.7 - Stripchart Page/Tab for more information.6-15 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-16 Liquid-liquid Hydrocyclone ww Th6.2 Liquid-liquid Hydrocyclone The HYSYS Liquid-liquid Hydrocyclone predicts the performance of an oily water cleaning unit operation. The Liquid-liquid Hydrocyclone generates results based on the Migration Probability Theory. An oil droplet size distribution based on a sauter mean diameter is applied and the resulting volume of oil separated is calculated. The Liquid-liquid Hydrocyclone is designed to be easy to use with a single input tab giving liner details and the oil droplet distribution. Process details, Hydrocyclone liner dimensionless parameters, and separation performance are calculated. You have the option of modelling three different types of liner: • Vortoil G-liners • Serck Baker Oilspin liners • Custom liners The fundamental calculation methods are similar for all the liners. The hydraulic parameters however vary considerably. Theory The Liquid-liquid Hydrocyclone operation performs the following calculations to generate the results: • Oil Droplet Distribution • Hydrocyclone Liner Dimensions • Hydrocyclone Hydraulics • Oil Droplet Migration Probability • Hydrocyclone Separation Efficiency6-16 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-17 ww ThOil Droplet Distribution The Liquid-liquid Hydrocyclone uses a Rosin Rammler Oil Droplet Distribution to describe the dispersion at the Inlet. A two parameter Cumulative Distribution is defined. The Cumulative Distribution is defined by the following equation: where: F(d) = cumulative distribution d = droplet diameter drm = Rosin Rammler modal diameter n = exponential power index The Rosin Rammler modal diameter drm can be related to another mean diameter dM by the following equation. where: f(d) = fraction undersize at diameter dM (6.10) (6.11) F d( ) 1 d drm --------⎝ ⎠ ⎛ ⎞ n –⎝ ⎠ ⎛ ⎞exp–= dM drm 1 f d( )–( )ln–[ ]1 n⁄×=6-17 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-18 Liquid-liquid Hydrocyclone ww ThHydrocyclone Liner Dimensions The Hydrocyclone Dimensions are based on the following variables: • Dimensions Schematic • Characteristic Diameter (D). The Hydrocyclone characteristic diameter is defined by the user. • Inlet Diameter (DIN). The Inlet diameter is set at 0.35D. • Underflow Diameter (DW). The Underflow diameter is set at 0.50D. • Overflow Diameter (DO). The Overflow diameter is defined by the user. • Taper Angles. The Taper angles and define the Separation section geometry. Figure 6.9 L1 L2 L3 L4 2D D D/2 θ1 θ2 DIN DO DW θ1 θ26-18 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-19 ww Th• Lengths. The length of each taper section is calculated from the Taper angles ( and ) and the characteristic diameter (D). The length from the end of the taper section to the liner tip is taken as 20D. These lengths are then summed to give a total liner Length (L). Hydrocyclone Hydraulics The Hydrocyclone can be modelled Hydraulically in a dimensionless manner assuming geometrically similar criteria. A Reynolds number and Hydrocyclone number can be defined using dimensions, fluid parameters, and operating conditions. Split Ratio and Maximum flow are also determined from the operating data. • Reynolds Number. ReD is expressed as: where: QT = volumetric flow rate = continuous phase density DH = Hydrocyclone Characteristic Diameter = continuous phase viscosity • Hydrocyclone Number. Hy75 relating to an oil droplet diameter d'75 may be defined as: (6.12) (6.13) θ1 θ2 ReD QT ρc× 900 π DH μc××× --------------------------------------------= ρc μc Hy75 QT Δρ d′75 2×× 3600 DH 3 μc×× ----------------------------------------=6-19 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-20 Liquid-liquid Hydrocyclone ww Thwhere: QT = volumetric flow rate = oil and water density difference d'75 = 75% Migration Probability Droplet Diameter DH = Hydrocyclone Characteristic Diameter = continuous phase viscosity The Hydrocyclone Number can also be related to the Reynolds number for similar geometric units by means of the following general equation: Experimental or Production performance data can be used to establish the values of a and b. These constants are Liner specific. • Split Ratio. Split Ratio is calculated from the user defined Pressure Differential Ratio (PDR) by means of a quadratic expression: where: = parameter values established from a curve fit to operating data • Maximum Flowrate. Maximum flow rate for the system is related to the pressure differential between the Inlet and Reject streams: where: nL = number of Liners PIN = Inlet pressure PREJ = Overflow pressure k, n = constant values established from hydraulic data (6.14) (6.15) (6.16) Δρ μc Hy75 a ReD( )b= F α PDR( )2 β PDR( ) γ+ += α β γ,, QMAX nL k PIN PREJ–( )n×=6-20 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-21 ww ThOil Droplet Migration Probability The method of Dense Dispersion Hydrocyclones is applied to predict the volume of oil separated from the Inlet stream. A Migration Probability for the droplet distribution is derived from statistical theory and a Reduced Migration Probability. • Migration Probability. For a given Inlet oil droplet distribution the Migration Probability (MP) of a droplet of diameter d microns is defined as the chance that it will be separated in the oil overhead stream. The MP can be related to the Reduced Migration Probability (RMP) and the Split Ratio (F) by the following expression: • Reduced Migration Probability. An analytical function may be fitted to represent the centre of an envelope of experimental curves for a particular liner. This Reduced Migration Probability (RMP) can be represented generally in terms of a normalised droplet diameter as: where: a, b, c = constants determined by experiment dimensionless droplet diameter d'75 = determined from the Hydrocyclone Number d = droplet diameter from the Distribution (6.17) (6.18) MP d( ) RMP d( ) 1 F–( )× F+= Δ75 RMP 1 a Δ75 b–[ ]c( )exp–= Δ75 d d′75 ---------=6-21 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-22 Liquid-liquid Hydrocyclone ww Th• Graphical Representation. The Migration Probability for an Oil Droplet Distribution is represented graphically as: Hydrocyclone Separation Efficiency The Separation Efficiency ( ) of the Hydrocyclone vessel is calculated from the under flow oil concerntration and inlet stream oil concentrations: where: Ci = inlet stream oil concentration (ppm) = under flow oil concentration (ppm) vliq = inlet liquid oil volume flow rate vof = over flow oil volume flow rate vuf = under flow volume flow rate Figure 6.10 (6.19) ε ε 100 1 Cuf Ci -------–⎝ ⎠ ⎛ ⎞= Cuf 1000000 vliq vof– vuf --------------------×=6-22 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-23 ww Th6.2.1 Liquid-liquid Hydrocyclone Property View There are two methods to add a Liquid-liquid Hydrocyclone to your simulation: 3. From the Flowsheet menu, click Add Operation. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 4. Click the Upstream Ops radio button. 5. From the list of available unit operations, select Liquid- liquid Hydrocyclone. 6. Click the Add button. The Liquid-liquid Hydrocyclone property view appears. In the case when no oil is in the under flow, the separation efficiency is 100% Figure 6.116-23 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-24 Liquid-liquid Hydrocyclone ww Th• To delete the Liquid-liquid Hydrocyclone operation, click the Delete button. HYSYS will ask you to confirm the deletion. You can also delete a Liquid-liquid Hydrocyclone by clicking on the Liquid-liquid Hydrocyclone icon on the PFD and pressing DELETE. • To ignore the Liquid-liquid Hydrocyclone during calculations, select the Ignored checkbox. HYSYS completely disregards the operation (and cannot calculate the outlet stream) until you restore it to an active state by clearing the checkbox. 6.2.2 Design Tab The Design tab consists of the following pages: • Connections • Parameters • Liner Details • Droplet Distribution • User Variables • Notes Connections Page The Connections page is used to define all of the connections to the Liquid-liquid Hydrocyclone. You can specify the inlet stream, overflow outlet stream, and underflow outlet stream attached to the operation. The name of Figure 6.126-24 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-25 ww Ththe operation can be changed in the Name field. You can select a different fluid package associated to the Liquid- liquid Hydrocyclone using the Fluid Package drop-down list. Parameters Page The Parameters page allows you to specify the Liquid-liquid Hydrocyclone operation parameters. The following table lists and describes the parameters available in the Parameters page: Figure 6.13 Object Description Liner Type drop- down list Allows you to choose between three types of Vessel liner: • Vortoil G-Liners • Serck Baker Oil Spin • Custom Liners Hydraulic parameters and physical Dimensions change between the three types of Liner. Number of Liners cell Allows you to specify the number of active vessel liners. Min. Flowrate cell Displays the minimum flow rate per liner depending on the selected Liner type. • Vortoil recommends a minimum value of 2m3/hr for the G-Liner. • Serck Baker recommends a minimum value of 4m3/hr for the OilSpin Liner. • Custom liner remains unchanged. Min. Reject Pressure cell Allows you to specify the minimum Oil Overflow (Reject) downstream pressure.6-25 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-26 Liquid-liquid Hydrocyclone ww ThAdvanced Parameters You cannot modify the coefficients of Vortoil G-liner nor Serck Baker Oil Spin, but you can view them on the Advanced Parameters page. The Vortoil G-liner will display the coefficients for Vortoil G-liner, and Serck Baker Oil Spin will display the coefficients for Serck Baker Oil Spin. However, if you choose Custom Liner, you can modify some of the coefficients. The following table illustrates how the coefficients on the Liners Details page react to your input: PDR cell Allows you to specify the Pressure Differential Ratio. The PDR is the ratio of the following stream pressure drops: Split Ratio cell Allows you to specify the volume percent of the total inlet stream that passes to the overflow stream. Underflow DP cell Allows you to specify the pressure difference between the inlet stream and the underflow stream. Underflow Pressure cell Displays the pressure of the underflow stream. Advanced Parameters Allows you to view coefficients of selected liners as well as enter coefficients when Custom Liner is selected. Function Result If you choose Custom Liner, then all numbers will remain unchanged, but the Characteristic Diameter and the Overflow Diameter become blue, and the remaining numbers become red. If you change the Characteristic Diameter, then the red default numbers will update according to calculations. If you modify one of the red default numbers, then that value becomes blue and will no longer update according to the code. If you subsequently delete the blue number, then that number will be replaced by the calculated number and appear in red. If Upper Taper Angle and Lower Taper Angle are deleted, then they will automatically return to the default values, 20 and 1.5. Object Description PDR Inlet Pressure Overflow Pressure– Inlet Pressure Underflow Pressure– --------------------------------------------------------------------------------------=6-26 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-27 ww ThIf you delete the Characteristic Diameter on the overflow diameter, then the values will go empty as well as all red numbers because there in no way to calculate the default data. If you reselect one of the liners, Vortoil G-liner or Serck Baker Oil Spin liner, from the dropdown list, then any entries on the Liner Details and the Advanced Parameters page will be lost. If the parameter fields are empty, then the status bar of the unit op should state the parameters are missing. If the parameters are changed, then the newly entered coefficients will be recalculated. Red numbers indicate a default coefficient. Blue numbers indicate a coefficient specified by the user. Black numbers indicate a coefficient that is unchangeable. Function Result6-27 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-28 Liquid-liquid Hydrocyclone ww ThLiner Details Page The Liner Details page allows you to manipulate the selected Liner type. The following table lists and describes the parameters available for modification in the Liner Details page: Figure 6.14 Object Description Liner Type drop- down list Allows you to choose between two types of Vessel liner: • Vortoil G-Liners • Serck Baker Oil Spin • Custom Liners Hydraulic parameters and physical Dimensions change between the two types of Liner. Characteristic Diameter cell Allows you to specify the liner characteristic diameter, which is used to determine the diameter for the Inlet and Underflow. Inlet Diameter cell Displays the calculated inlet diameter value. Upper Taper cell Displays the upper taper angle. Lower Taper cell Displays the lower taper angle. Overflow Diameter cell Allows you to specify the Overflow diameter. Underflow Diameter cell Displays the calculated Underflow diameter based on the selected Liner type and the specified characteristic diameter. Total Length cell Displays the Liner overall length of the selected Liner type’s hydrocyclone geometry.6-28 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-29 ww ThDroplet Distribution Page The Droplet Distribution page allows you to manipulate the Liquid-liquid Hydrocyclone performance, by modifying the dispersed oil droplet distribution. The size distribution of oil droplets at the Hydrocyclone inlet is calculated using two parameters of the Rosin Rammler distribution. The Rosin Rammler distribution calculation is based on a mean droplet diameter and an exponential term power index. The following table lists and describes the distribution parameters: Choose one of the two radio buttons on the Design page to receive either volume-based results or number-based results. Figure 6.15 Parameter Description Droplet Sauter Mean This is the droplet diameter whose volume to surface area ratio is the same as that of the distribution as a whole and so represents the surface area mean diameter. Droplet d50 This is the diameter of droplet at the 50% undersize point on a cumulative volume distribution curve. Droplet d95 This is the diameter of droplet at the 95% undersize point on a cumulative volume distribution curve. Rosin Rammler Index This is the power term to which the exponential part of the Rosin-Rammler Distribution is raised. Usually the value is between 1 and 2.5.6-29 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-30 Liquid-liquid Hydrocyclone ww ThUser Variables Page The User Variables page allows you to create and implement variables in the HYSYS simulation case. Notes Page The Notes page provides a text editor that allows you to record any comments or information regarding the specific unit operation, or the simulation case in general. 6.2.3 Performance Tab The Performance tab displays the calculated performance results of the Liquid-liquid Hydrocyclone. General Page The General page displays the calculated general Liner performance results. • Inlet oil concentration in parts per million (ppm) by volume and mg/l • Maximum flow rate for the vessel. This value is calculated from the Liner hydraulic characteristics. • Droplet diameter separated with 75% efficiency at operating conditions Figure 6.16 For more information on implementing the User Variables, refer to Chapter 5 - User Variables in the HYSYS Customization For more information, refer to Section 7.19 - Notes Manager in the HYSYS User Guide.6-30 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-31 ww Th• Pressure drops at Overflow and Underflow relative to the Inlet • System Reject Ratio • System separation efficiency Geometric Page The Geometric page displays the calculated geometric Liner performance results. • Hydrocyclone Reynolds Number based on the Characteristic diameter • Hydrocyclone Number (Hy75) Overflow Page The Overflow page displays the calculated Overflow results. Figure 6.17 Figure 6.186-31 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-32 Liquid-liquid Hydrocyclone ww Th• Overflow pressure • Volumetric flowrate • Oil concentration in ppm Underflow Page The Underflow page displays the calculated Underflow results. • Underflow pressure • Volumetric flowrate • Oil concentration in ppm and mg/l Figure 6.196-32 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-33 ww ThTables Page The Tables page displays the tabulated results of the Oil Droplet Distribution or the Migration Probability. To view either results select the appropriate radio button. Plots Page The Plots page displays in graph format the results of the Oil Droplet Distribution or the Migration Probability. To view either plot select the appropriate radio button. Figure 6.20 Figure 6.216-33 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-34 Liquid-liquid Hydrocyclone ww Th6.2.4 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. 6.2.5 Dynamics Tab This unit operation is currently not available for dynamic simulation. 6.2.6 Nomenclature The following Nomenclature has been adopted for the Liquid- liquid Hydrocyclone calculations: Variable Symbol Units Volumetric Flowrate m3/hr Maximum Volumetric Flowrate m3/hr Inlet Pressure Bar Overflow Pressure Bar Underflow Pressure Bar Continuous Phase Density kg/m3 Oil Droplet Density kg/m3 Hydrocyclone Characteristic Diameter m Continuous Phase Viscosity Pa.s Droplet Diameter microns Sauter Mean Droplet Diameter microns 50% Droplet Diameter microns 75% Droplet Diameter microns 95% Droplet Diameter microns Refer to Section 1.3.10 - Worksheet Tab in the HYSYS Operations Guide for more information. QT QMAX PIN PREJ POUT ρc ρo D μc d d3 2, d50 d75 d956-34 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-35 ww Th6.3 Mixer The Mixer operation combines two or more inlet streams to produce a single outlet stream. A complete heat and material balance is performed with the Mixer. That is, the one unknown temperature among the inlet and outlet streams is always calculated rigorously. If the properties of all the inlet streams to the Mixer are known (temperature, pressure, and composition), the properties of the outlet stream is calculated automatically since the composition, pressure, and enthalpy is known for that stream. The mixture pressure and temperature are usually the unknowns to be determined. However, the Mixer also calculates backwards and determine the missing temperature for one of the inlet streams if the outlet is completely defined. In this latter case, the pressure must be known for all streams. 75% Migration Probability Droplet Diameter microns Dimensionless Droplet Diameter Pressure Differential Bar Separation Efficiency % Inlet Oil Concentration ppm Vol. Underflow Oil Concentration ppm Vol. Split Ratio Hydrocyclone Reynolds Number Hydrocyclone Number Number of Liners Total Liner Length m Upper Taper Angle degrees Lower Taper Angle degrees Variable Symbol Units d′75 Δ75 ΔP ε Ci Co F ReD Hy75 nL L θ1 θ26-35 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-36 Mixer ww ThThe Mixer flashes the outlet stream using the combined enthalpy. Notice that when the inlet streams are completely known, no additional information needs to be specified for the outlet stream. The problem is completely defined; no degrees of freedom remain. The dynamic Mixer operation functions very similarly to the steady state Mixer operation. However, the enhanced holdup model and the concept of nozzle efficiencies can be applied to the dynamic Mixer. Flow reversal is also possible in the Mixer depending on the pressure-flow conditions of the surrounding unit operations. 6.3.1 Mixer Property View There are two ways that you can add a Mixer to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Piping Equipment radio button. 3. From the list of available unit operations, select Mixer. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the Mixer icon. The resultant temperature of the mixed streams may be quite different than those of the feed streams due to mixing effects. Mixer icon6-36 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-37 ww ThThe Mixer property view appears. 6.3.2 Design Tab The Design tab provides access to the following pages: • Connections • Parameters • User Variables • Notes Figure 6.226-37 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-38 Mixer ww ThConnections Page On the Connections page, you can specify the following: • any number of inlet streams to the mixer • a single outlet stream • name for the mixer • fluid package associated to the mixer Parameters Page The Parameters page allows you to indicate the type of Automatic Pressure Assignment, HYSYS should use for the streams attached to the Mixer. Figure 6.23 Figure 6.246-38 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-39 ww ThThe default is Set Outlet to Lowest Inlet, in which case all but one attached stream pressure must be known. HYSYS assigns the lowest inlet pressure to the outlet stream pressure. If you specify Equalize All, HYSYS gives all attached streams the same pressure once one of the attached stream pressures are known. If you want to specify all of the inlet stream pressures, ensure first that all pressures have been specified before installing the Mixer, then choose Set Outlet to Lowest Inlet. In this case, there is no automatic pressure assignment since all the stream pressures are known. If you are uncertain of which pressure assignment to use, choose Set Outlet to Lowest Inlet. Only use Equalize All if you are completely sure that all the attached streams should have the same pressure. While the pressure assignment seems to be extraneous, it is of special importance when the Mixer is being used to simulate the junction of multiple pipe nodes. User Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. If you select Equalize All and two or more of the attached streams have different pressures, a pressure inconsistency message appears. In this case, you must either remove the pressure specifications for all but one of the attached streams, or select Set Outlet to Lowest Inlet. If you specify Set Outlet to Lowest Inlet, you can still set the pressures of all the streams. For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.6-39 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-40 Mixer ww Th6.3.3 Rating Tab You need HYSYS dynamics to specify any rating information for the Mixer operation. The Rating tab consists of the Nozzles page. Nozzles Page The Nozzles page contains information regarding the elevation and diameter of the nozzles. It is strongly recommended that the elevation of the inlet and exit nozzles are equal for this unit operation. If you want to model static head, the entire piece of equipment can be moved by modifying the Base Elevation relative to Ground Elevation field. 6.3.4 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. 6.3.5 Dynamics Tab The Dynamics tab contains the following pages: • Specs • Holdup • Stripchart In Dynamic mode, changes in inlet streams to the Mixer are seen instantaneously in the outlet stream because the Mixer is assumed to have no holdup. The PF Specs page is relevant to dynamics cases only. Refer to Section 1.3.6 - Nozzles Page for more information. Refer to Section 1.3.10 - Worksheet Tab for more information.6-40 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-41 ww ThSpecs Page The dynamic specifications of the Mixer can be specified on the Specs page. In dynamic mode, there are two possible dynamic specifications you can choose to characterize the Mixer operation: • If you select the Equalize All radio button, the pressure of the surrounding streams of the Mixer are equal if static head contributions are not considered. This is a realistic situation since the inlet stream pressures to a Mixer in an actual plant must be the same. With this specification, flow to and from the Mixer is determined by the pressure flow network. The “one PF specification per flowsheet boundary stream” rule applies to the Mixer operation if the Equalize All option is chosen. It is strongly recommended that you use the Equalize All option in order to realistically model flow behaviour in a dynamic simulation case. • If you select the Set Outlet to Lowest Inlet radio button, HYSYS sets the pressure of the exit stream of the Mixer to the lowest inlet stream pressure. This situation is not recommended since two or more streams can enter the Mixer at different pressures which is not realistic. With this specification, flow to and from the Mixer is determined from upstream flow specifications, and not from the surrounding pressure network of the simulation case. If this option is used, n more pressure- If you are working exclusively in Steady State mode, you are not required to change any information on the pages accessible through the Dynamics tab. Figure 6.256-41 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-42 Mixer ww Thflow specifications are required by the PF solver than if the Equalize All option is used. The variable, n, is the number of inlet streams to the Mixer. The Product Molar Flow Factor field enables you to scale the flow rate coming out of the mixer. For example, there are two parallel trains but you only want to model one train. You can accomplish modeling one train by changing the Product Molar Flow Factor value, so that the flow rate out of the mixer equals the flow rate value into the mixer multiplied by the Product Molar Flow Factor value. Holdup Page Each unit operation in HYSYS has the capacity to store material and energy. Typical Mixers in actual plants usually have significantly less holdup than other unit operations in a plant. Therefore, the volume of the Mixer operation in HYSYS cannot be specified and is assumed to be zero. Since there is no holdup associated with the Mixer operation, the holdup’s quantity and volume are shown as zero in the Holdup page. The Disable flashes checkbox enables you to turn on and off the rigorous flash calculation for the mixer. This feature is useful Reverse flow conditions can occur in the Mixer operation if the Equalize All radio button is not selected. If flow reverses in the Mixer, the Mixer essentially acts like a dynamic Tee with the Use Splits as Dynamic Specs checkbox inactive. In dynamics, these two unit operations are very similar. Figure 6.26 Refer to Section 1.3.3 - Holdup Page for more information. 6-42 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-43 ww Thif the PFD has a very large number of mixers, and you do not care whether the contents of the streams around them are fully up to date or not, or you prefer maximum speed in the simulation calculation. • To turn off the flash calculation, select the Disable flashes checkbox. If the flash calculations are turned off, the outlet stream will still update and propagate values, but the phase fractions and temperatures may not be correct. • To turn the flash calculation back on, clear the Disable flashes checkbox. The default selection is to leave the flash calculation on. Stripchart Page The Stripchart page allows you to select and create default strip charts containing various variable associated to the operation. 6.4 Pipe Segment The Pipe Segment is used to simulate a wide variety of piping situations ranging from single or multiphase plant piping with rigorous heat transfer estimation, to a large capacity looped pipeline problems. It offers several pressure drop correlations: • Aziz, Govier, and Fogarasi • Baxendell and Thomas • Beggs and Brill • Duns and Ros • Gregory Aziz Mandhane • Hagedorn and Brown • HTFS, Liquid Slip • HTFS, Homogeneous Flow HYSYS recommend that the flash calculations be left on, as in some cases disabled flash calculation can result in instabilities or unexpected outcomes, depending on what is downstream of the unit operation where the flash has been turned off. This feature should only be manipulated by advanced users. Refer to Section 1.3.7 - Stripchart Page/Tab for more information.6-43 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-44 Pipe Segment ww Th• OLGAS2000_2P • OLGAS2000_3P • Orkiszewski • Poettmann and Carpenter • Tulsa 99 Another option, OLGAS, is also available as a gradient method. Four levels of complexity in heat transfer estimation allow you to find a solution as rigorous as required while allowing for quick generalized solutions to well-known problems. The Pipe Segment offers four calculation modes. The appropriate mode is automatically selected depending on the information specified. In order to solve the pipe, you must specify enough information to completely define both the material balance and energy balance. Calculation Modes The Pipe Segment operation contains four calculation modes: • Pressure Drop • Length • Flow • Diameter The mode is automatically assigned depending on what information is specified. OLGAS is a third-party option which can be purchased through AspenTech or SCANDPOWER. HYSYS checks for sonic flow if indicated by the option in the Calculation page of the Design tab. Contact your AspenTech agent for more information, or e-mail us at info@aspentech.com.6-44 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-45 ww ThRegardless of which mode you use, you must specify the number of increments in the pipe. Calculations are performed in each increment; for example, to determine the pressure drop, the energy and mass balances calculations are performed in each increment, and the outlet pressure in that increment is used as the inlet pressure to the next increment. The calculation continues down the length of the pipe until the pipe outlet pressure is determined. The Pipe Segment can solve in either direction. The solution procedure generally starts at the end where the temperature is known (temperature is typically not known on both ends). HYSYS then begins stepping through the pipe from that point, using either the specified pressure, or estimating a starting value. If the starting point is the pipe outlet, HYSYS steps backwards through the pipe. At the other end of the pipe, HYSYS compares the calculated solution to other known information and specifications, and if necessary, restarts the procedure with a new set of starting estimates. Some specifics of each calculation mode are provided in the following sections. Pressure Drop Assuming that a feed, product, and energy stream are attached to the pipe, the following information is required: • Flow • Pipe length, diameter, and elevation change • Heat transfer information • At least one stream temperature and one pressure There are two different methods for calculating the pressure drop, which are discussed below:6-45 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-46 Pipe Segment ww ThMethod 1 If you specify the temperature and pressure at the same end of the pipe, then energy and mass balances are solved for each increment, and the temperature and pressure of the stream at the opposite end of the pipe are determined. Delta P Method 1: 1. At the end where temperature and pressure are specified, solve for the outlet temperature and pressure in the first segment. 2. Move to the next segment, using the outlet conditions of the previous segment as the new inlet conditions. 3. Continue down the pipe until the outlet pressure and temperature are solved. Method 2 If you specify temperature for one stream and pressure for the other, an iterative loop is required outside of the normal calculation procedure: • First, a pressure is estimated for the stream which has the temperature specified. • Second, the pressure and temperature for the stream at the opposite end of the pipe are determined from incremental energy and mass balances as in the first method. • If the calculated pressure and user-specified pressure are not the same (within a certain tolerance), a new pressure is estimated and the incremental energy and mass balances are re-solved. This continues until the absolute difference of the calculated and user-specified pressures are less than a certain tolerance. The calculated pressure drop accounts for fittings, frictional, and hydrostatic effects.6-46 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-47 ww ThDelta P Method 2: 1. Estimate a pressure for the stream which has a specified temperature. 2. At the end where the pressure is estimated, solve for the outlet temperature and pressure in the first segment. 3. Move to the next segment, using the outlet conditions of the previous segment as the new inlet conditions. 4. Continue down the pipe until the outlet pressure and temperature are solved. 5. If the calculated outlet pressure is not equal to the actual pressure, a new estimate is made for pressure (Return to 1). Length Assuming that the feed, product, and energy stream are attached, the following information is required: • Flow • Heat transfer information • Pipe diameter • Inlet and Outlet Pressure (or one stream Pressure and Pressure Drop) • One stream temperature • Initial estimate of Length For each segment, the Length estimate, along with the known stream specifications, are used to solve for the unknown stream temperature and pressure. If the calculated pressure is not equal to the actual pressure (within the user-specified tolerance), a new estimate is made for the length, and calculations continue. A good initial guess and step size decreases the solving time. The Pipe also solves for the length if you provide one pressure, two temperature specifications, and the duty.6-47 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-48 Pipe Segment ww ThLength Calculation: 1. Estimate a Length. At the end where temperature is specified, solve for the outlet temperature and pressure in the first segment. 2. Move to the next segment, using the outlet conditions of the previous segment as the new inlet conditions. 3. Continue down the pipe until the outlet pressure and temperature are solved. 4. If the calculated outlet pressure is not equal to the actual pressure, a new estimate is made for length. (Return to 1). Diameter Information required in the Diameter calculation mode is the same as Length, except HYSYS requires the length instead of the diameter of the pipe. Initial estimate of diameter can be given on the Calculation page of the Design tab. Flow Assuming that a feed, product, and energy stream are attached to the pipe, the following information is required: • Pipe length and diameter • Heat transfer information • Inlet and Outlet Pressure (or one stream Pressure and Pressure Drop) • One stream temperature • Initial estimate of Flow Using the flow estimate and known stream conditions (at the end with the known temperature), HYSYS calculates a pressure at the other end. If the calculated pressure is not equal to the actual pressure (within the user-specified tolerance), a new estimate is made for the flow, and calculations continue. Again, a good initial guess decreases the solving time significantly. Both length and diameter calculations can only be done for pipes with a single segment.6-48 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-49 ww ThFlow Calculation: 1. Estimate Flow. At the end where temperature is specified, solve for the outlet temperature and pressure in the first segment. 2. Move to the next segment, using the outlet conditions of the previous segment as the inlet conditions. 3. Continue down the pipe until the outlet pressure and temperature are solved. 4. If the calculated outlet pressure is not equal to the actual pressure, a new estimate is made for the flow. (Return to 1). Incremental Material and Energy Balances The overall algorithm consists of three nested loops. The outer loop iterates on the increments (Pressure, Length or Flow Mode), the middle loop solves for the temperature, and the inner loop solves for pressure. The middle and inner loops implement a secant method to speed convergence. The pressure and temperature are calculated as follows: 1. The inlet temperature and pressure are passed to the material/energy balance routine. 2. Using internal estimates for temperature and pressure gradients, the outlet temperature and pressure are calculated. 3. Average fluid properties are calculated based on the inlet and estimated outlet conditions. 4. These properties, along with the inlet pressure, are passed to the pressure gradient algorithm. 5. With the pressure gradient, the outlet pressure can be calculated. 6. The calculated pressure and estimate pressure are compared. If their difference exceeds the tolerance (default value 0.1 kPa), a new outlet pressure is estimated, and steps #3 to #6 are repeated. The tolerance is specified in the Calculation page of the Design tab. 7. Once the inner pressure loop has converged, the outlet temperature is calculated:6-49 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-50 Pipe Segment ww Th• If U and the ambient temperature are specified, then the outlet temperature is determined from the following equations: where: Q = amount of heat transferred U = overall heat transfer coefficient A = outer heat transfer area = log mean temperature difference Qin = heat flow of inlet stream Qout = heat flow of outlet stream • If both the inlet and outlet Pipe temperatures are known, the outlet temperature of the increment is calculated by linear interpolation. The attached duty stream then completes the energy balance. • If duty is known, the outlet temperature is calculated from a Pressure-Enthalpy flash. When the Increment outlet temperature is calculated, it is compared with the estimated outlet temperature. If their difference exceeds the tolerance (default value 0.01oC), a new outlet temperature is estimated, and new fluid properties are calculated (return to step #3). The tolerance is specified in the Calculation page of the Design tab. 8. When both the temperature and pressure converge, the outlet results are passed to the inlet of the next increment, where calculations continue. (6.20) (6.21) Q U A ΔTLM××= Q Qin Qout–= ΔTLM6-50 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-51 ww Th6.4.1 Pipe Segment Property View There are two methods to add a Pipe Segment to the simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Piping Equipment radio button. 3. From the list of available unit operations, select Pipe Segment. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the Pipe Segment icon. The Pipe Segment property view appears. Figure 6.27 Pipe Segment icon6-51 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-52 Pipe Segment ww Th6.4.2 Design Tab The Design tab contains the following pages: • Connections • Parameters • Calculation • User Variables • Notes Connections Page On the Connections page, you must specify the feed and product material streams. In addition to the material stream connections, you also have the option of attaching an energy stream to the Pipe Segment and selecting the fluid package for the Pipe Segment. You can also edit the Pipe Segment name on this page. In the Inlet, Outlet and Energy drop-down lists either type in the name of the stream or if you have pre-defined your stream select it from the drop-down list. Figure 6.286-52 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-53 ww ThParameters Page In the Pipe Flow Correlation group, you can select the correlation method used for Two Phase (VL) flow calculations. The options are: • Aziz, Govier, and Fogarasi • Baxendell and Thomas • Beggs and Brill • Duns and Ros • Gregory Aziz Mandhane • Hagedorn and Brown • HTFS, Liquid Slip • HTFS, Homogeneous Flow • OLGAS2000_2P • OLGAS2000_3P • Orkiszewski • Poettmann and Carpenter • Tulsa 99 Figure 6.29 OLGAS is a third-party option that can be purchased through AspenTech or SCANDPOWER.6-53 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-54 Pipe Segment ww ThSummary of Methods The methods above have all been developed for predicting two- phase pressure drops. Some methods were developed exclusively for flow in horizontal pipes, others exclusively for flow in vertical pipes while some can be used for either. Some of the methods define a flow regime map and can apply specific pressure drop correlations according to the type of flow predicted. Some of the methods calculate the expected liquid holdup in two-phase flow while others assume a homogeneous mixture. The table below summarizes the characteristics of each model. More detailed information on each model is presented later in this section. For Single Phase streams, the Darcy equation is used for pressure drop predictions. This equation is a modified form of the mechanical energy equation, which takes into account losses due to frictional effects as well as changes in potential energy. The total heat loss from the Pipe Segment is indicated in the Duty field. The total heat loss can be calculated using estimated heat transfer coefficients or specified on the Heat Transfer page of the Rating tab. Model Horizontal Flow Vertical Flow Liquid Holdup Flow Map Aziz, Govier & Fogarasi No Yes Yes Yes Baxendell & Thomas Use with Care Yes No No Beggs & Brill Yes Yes Yes Yes Duns & Ros No Yes Yes Yes Gregory, Aziz, Mandhane Yes No Yes Yes Hagedorn & Brown No Yes Yes No HTFS Homogeneous Yes Yes No No HTFS Liquid Slip Yes Yes Yes No Olgas2000 Yes Yes Yes Yes Orkisewski No Yes Yes Yes Poettman & Carpenter No Yes No No Tulsa No Yes Yes Yes6-54 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-55 ww ThYou can also specify the overall pressure drop for the operation. The pressure drop includes the losses due to friction, static head, and fittings. If the overall pressure drop is not specified on the Parameters page, it is calculated by HYSYS, provided all other required parameters are specified. The Gravitational Energy Change field displays the change in potential energy experienced by the fluid across the length of the pipe. It is determined for the overall elevation change, based on the sum of the elevation change specified for each segment on the Sizing page of the Rating tab. When the pressure drop is specified, the Pipe Segment can be used to calculate either the length of the Pipe Segment or the flow of the material through the length of pipe. Notice the calculation type (for example, pressure drop, length, flow) is not explicitly specified. HYSYS determines what is to be calculated by the information that you provide. The overall pressure drop, which can be specified or calculated by HYSYS, is the sum of the friction, static head, and fittings pressure drops. When two liquid phases are present, appropriate volume based empirical mixing rules are implemented to calculate a single pseudo liquid phase. Therefore, caution should be exercised in interpreting the calculated pressure drops for three-phase systems. Actual pressure drops can vary dramatically for different flow regimes, and for emulsion systems.6-55 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-56 Pipe Segment ww ThAziz, Govier & Fogarasi In developing their model2 Aziz, Govier & Fogarasi argue that flow regime is independent of phase viscosities and pipe diameters but is proportional to the gas density to the one third power ( ). From this, then the calculate modified superficial gas and liquid velocities on which they base the following flow regime map. Once the flow regime has been determined a range of correlations is used to determine the frictional pressure gradient and slip velocity or void fraction applicable to that regime. Figure 6.30 ρg 1 3⁄6-56 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-57 ww ThBaxendell & Thomas The Baxendell & Thomas model3 is an extension of the Poettman & Carpenter model to include higher flow rates. It is based on a homogeneous model using a two-phase friction factor obtained from correlation based on experimental results relating friction factor to the parameter . Baxendell & Thomas fitted a smooth curve for values of the parameter greater than 45 x103 cp. Below this value they propose that original correlation of Poettman & Carpenter be used. Baxendell & Thomas claim the correlation is suitable for use in calculating horizontal flow pressure gradients in addition to the vertical flow pressure gradients for which the original Poettman & Carpenter approach was developed although the correlation takes no account of the very different flow regimes that can occur. Like the Poettman & Carpenter model this model assumes that the pressure gradient is independent of viscosity. Beggs and Brill Pressure Gradient The Beggs and Brill4 method is based on work done with an air- water mixture at many different conditions, and is applicable for inclined flow. Dρυ Dρυ6-57 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-58 Pipe Segment ww ThIn the Beggs and Brill correlation, the flow regime is determined using the Froude number and inlet liquid content. The flow map used is based on horizontal flow and has four regimes: segregated, intermittent, distributed, and transition. The types of flow in the first three regime are listed as follows: • Segregated Flow: Stratified, Wavy, and Annular. • Intermittent Flow: Plug and Slug. • Distributed Flow: Bubble and Mist. Once the flow regime has been determined, the liquid holdup for a horizontal pipe is calculated, using the correlation applicable to that regime. A factor is applied to this holdup to account for pipe inclination. From the holdup, a two-phase friction factor is calculated and the pressure gradient determined. Figure 6.31 Beggs and Brill Flow Regimes 0.010.0001 0.001 0.1 1 Input Liquid Content Fr o u d e N u m b er 1 10 100 1000 Distributed Segregated Transition Intermittent6-58 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-59 ww ThDuns & Ros The Duns and Ros model8 is based on a large scale laboratory investigation of upward vertical flow of air / hydrocarbon liquid and air / water systems. The model identifies three flow regions, outlined below. • Region I. Where the liquid phase is continuous (in other words, bubble and plug flow, and part of froth flow regimes). • Region II. Where the phases of liquid and gas alternate (in other words, remainder of froth flow regime and slug flow regime). • Region III. Where gas phase is continuous (in other words, mist flow and annular flow regime). The flow region map is shown in the figure below: Figure 6.326-59 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-60 Pipe Segment ww ThThe regions are distinguished using functions of four dimensionless groups namely a gas velocity number, a liquid velocity number, a diameter number, and a liquid viscosity number. Separate frictional pressure drop correlations and liquid slip velocity (liquid holdup) correlations are defined for each region in terms of the same dimensionless groups. Gregory Aziz Mandhane Pressure Gradient For the Gregory Aziz Mandhane correlation10, an appropriate model is used for predicting the overall pressure drop in two- phase flow. Figure 6.33 Gregory Aziz Mandhane Flow Regimes Regime Model Slugflow Mandhane, et. al. modification #1 of Lockhart-Martinelli Dispersed Bubble Mandhane, et. al. modification #2 of Lockhart- Martinelli Annular Mist Lockhart-Martinelli Elongated Bubble Mandhane, et. al. modification #1 of Lockhart-Martinelli Superficial Gas Velocity (m/sec) S u p er fi ci a l Li q u id V el oc it y (m /s ec ) Bubble, Elongated Bubble Flow Stratified Flow Dispersed Flow Slug Flow Wave Flow Annular, Annular Mist Flow6-60 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-61 ww ThHagedorn & Brown Hagedorn & Brown based their model11 on experimental data on upward flow of air / water and air / oil mixtures. The frictional pressure drop is calculated using a friction factor derived from a single phase Moody curve using a two phase Reynolds number that reduces to the appropriate single phase Reynolds number when the flow becomes single phase. For the void fraction required to calculate the two phase Reynolds number and the static pressure loss, Hagedorn & Brown developed a single curve relating the void fraction to the same dimensionless parameters proposed by Duns & Ros. HTFS Models The two HTFS models12, 17 share a common method for calculating the frictional pressure gradient and acceleration pressure gradient while differing in the method used to calculate static pressure gradient. The frictional pressure gradient method is adapted from that of Claxton et. al. (1972). The method first calculates the frictional pressure drop for the gas and liquid phases assuming that they are flowing alone in the pipe based on Fanning friction factors for each phase that are again calculated by assuming the fluid is flowing alone in the pipe. The frictional pressure drop is then calculated from the formula: where: = frictional pressure drop = liquid phase pressure drop Stratified Lockhart-Martinelli Wave Lockhart-Martinelli (6.22) Regime Model pF pl Cc pl pgΔΔ( ) pgΔ+ +Δ=Δ pFΔ plΔ6-61 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-62 Pipe Segment ww ThCc = correction factor calculated from the properties of the liquid and gas phases and the superficial mass velocities of the phases = gas phase pressure drop The static pressure gradient is calculated from a separated model of two phase flow. In the HTFS Homogeneous model the void fraction required by this model is assumed to be the homogeneous void fraction. In the HTFS Liquid Slip model the void fraction is calculated using a method published by Whalley and Ward (1981). The accelerational gradient term is calculated from a homogeneous equation model. The HTFS models have been validated for horizontal, and both upward and downward vertical flow using a wide range of data held by the Harwell data bank. OLGAS2000 (2-Phase & 3-Phase) OLGAS2000 employs mechanistic models for each of the four major flow regimes: stratified, annular, slug, and dispersed bubble flow. It is based in large part on data from the SINTEF multiphase flow laboratory in Norway. Multiphase Flow is a dynamic physical process between the phases. It includes fluid properties, complex geometry and interaction between reservoir, well, flowline and process plant. OLGAS 2000 can handle 2-phase and 3-phase flow. For instance, the elements involved can consist of water droplets, oil, gas, sand, wax, and hydrates. OLGAS2000 predicts the pressure gradient, liquid holdup, and flow regime. It has been tested in one degree increments for all angles from horizontal to vertical. OLGAS2000 gives one of the best overall predictions of pressure drop and liquid holdup of any currently available method. Contact your AspenTech agent for more information on OLGAS2000 and the licensing on OLGAS2000 3-Phase. pgΔ6-62 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-63 ww ThOrkisewski Orkisewski15 composed a composite correlation for vertical upward flow based on a combination of methods developed by Griffith (1962), Griffith & Wallis(1961), and Duns & Ros (1963)8. Four flow regimes are defined and the methods proposed for each region are: • Bubble flow—Griffith correlation • Slug/Plug flow—Griffith & Wallis correlation modified by Orkisewski • Churn flow—Duns & Ros • Mist/Annular flow—Duns & Ros Orkisewski proposed that the method of Griffith and Wallis be used to determine the boundary between the bubble and plug flow regime and the methods of Duns & Ros be used to determine the remaining flow regime boundaries. Poettman & Carpenter The Poettman & Carpenter model16 assumes that the contribution of the acceleration term to the total pressure loss is small and that the frictional pressure drop can be calculated using a homogeneous model. The model further assumes that the static head loss can be calculated using a homogeneous two phase density. Poettman & Carpenter varies from a standard homogeneous method in its calculation of a two phase friction factor. The model proposes a correlation for the friction factor based on experimental results from 49 flowing and gas lift wells operating over a wide range of conditions. The two-phase friction factor is plotted against the parameter (D= diameter, = homogeneous density, and = homogeneous superficial velocity). Effectively therefore the model assumes that the pressure gradient is independent of viscosity. Dρυ ρ υ6-63 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-64 Pipe Segment ww ThTulsa The Tulsa model18 proposes a comprehensive mechanistic model formulated to predict flow patterns, pressure drop, and liquid holdup in vertical upward two-phase flow. The model identifies five flow patterns: bubble, dispersed bubble, slug, churn, and annular. The flow pattern prediction models used are Ansari et. al. (1994) for dispersed bubble and annular flows, Chokshi (1994) for bubbly flow and a new model for churn flow. The resulting flow pattern map is shown below. Separate hydrodynamic models for each flow pattern are used. A new hydrodynamic model is proposed for churn flow and a modified version of Chokshi’s model is proposed for slug flow. Chokshi and Ansari et. al. models are adopted for bubbly and annular flows respectively. The model has been evaluated using the Tulsa University Fluid Flow Projects well data back of 2052 wells covering a wide range of field data. The model has been compared with Ansari et. al. (1994), Chokshi (1994), Hasan & Kabir (1994), Aziz et. al. (1972), and Hagedorn and Brown (1964) methods, and is Figure 6.346-64 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-65 ww Thclaimed to offer superior results. Calculation Page You can specify any of the calculation parameters on this page. The table below describes the parameters. All methods account for static head losses, while Aziz, Beggs and Brill, and OLGAS methods account for hydrostatic recovery. Beggs and Brill calculate the hydrostatic recovery as a function of the flow parameters and pipe angle. Figure 6.35 Field Description Pressure Tolerance Tolerance used to compare pressures in the calculation loop. Temperature Tolerance Tolerance used to compare temperatures in the calculation loop. Heat Flow Tolerance Tolerance used to compare heat flow in the calculation loop. Length Initial Guess Used in the algorithm when length is to be calculated. Length Step Size Used in the algorithm when length is to be calculated. Flow Initial Guess Used in the algorithm when flow of material is to be calculated. Flow Step Size Used in the algorithm when flow of material is to be calculated Diameter Initial Guess Optional estimate when diameter is to be calculated.6-65 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-66 Pipe Segment ww ThUser Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. Default Increments The increment number which appears for each segment on the Dimensions page Always PH Flash Selecting this checkbox, force HYSYS’ calculations to be done using PH flashes rather than PT flashes. Slower but more reliable for pure component or narrow boiling range systems. Check Choked Flow When this checkbox is active, HYSYS checks for choked flow. The default setting is inactive because the command slows down calculations. This check is carried out only on pipe segments not on fitting or swage segments. Do Deposition Calcs When this checkbox is inactive, HYSYS turns off deposition calculations. This checkbox is a duplicate of the checkbox on the Deposition tab Do Slug Tool Calculations When this checkbox is active, HYSYS performs slug calculations. When calculating Flow or Length, good initial guesses and step sizes can greatly reduce solution time. Field Description For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.6-66 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-67 ww Th6.4.3 Rating Tab The Rating tab provides access to the following pages: • Sizing • Heat Transfer On the Sizing page, you can specify information regarding the dimensions of sections in the Pipe Segment. In the Heat Transfer page, the heat loss of the Pipe Segment can either be specified or calculated from various heat transfer parameters. Sizing Page On the Sizing page, the length-elevation profile for the Pipe Segment is constructed. You can provide details for each fitting or pipe section that is contained in the Pipe Segment that you are modeling. An unlimited number of pipe sections or fittings can be added on this page. For a given length of pipe which is modelled in HYSYS, the parameters of each segment is entered separately, as they are for each fitting. The procedure for modeling a length of pipe is illustrated using the diagram shown below. In the diagram, the pipe length AD is represented by segments A, B, C, D, and three fittings. The table shown below displays the fitting/pipe, length, and elevation input that you require to represent the pipe length AD. Figure 6.36 X1 X2 X3 Y1 Y2 F2 A C D B Example of Pipe Sections and Fittings Modelled in the Pipe Segment Operation Fittings F3 F16-67 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-68 Pipe Segment ww ThEach pipe section and fitting is labelled as a segment. To fully define the pipe section segments, you must also specify pipe schedule, diameters (nominal or inner and outer), a material, and a number of increments. The fittings require an inner diameter value. Adding Segments You can add segments to the length-elevation profile by clicking the Append Segment button. For each segment that you add, you must specify the following: Number 1 2 3 4 5 6 7 Represented by A F1 B F2 C F3 D Fitting/Pipe Pipe Fitting Pipe Fitting Pipe Fitting Pipe Length x1 N/A y1 N/A x2 N/A Elevation 0 N/A y1 N/A 0 N/A y2 x3 2 y2 2+ The horizontal pipe sections have an Elevation of 0. A positive elevation indicates that the outlet is higher than the inlet. When you have only one pipe segment HYSYS calculates the inner diameter of the pipe when a pressure difference and pipe length is specified. Field Description Pipe/Fitting/ Swage Select a pipe section, swage or one of the available fittings from the drop-down list. If the list does not contain the fitting required, you can modify the fittings and change its K-factor for these calculations. You can modify the Fittings Database, which is contained in file FITTING.DB. Length The actual length of the Pipe Segment. Not required for fittings. Elevation Change The change in vertical distance between the outlet and inlet of the pipe section. Positive values indicate that the outlet is higher than the inlet. Not required for fittings. Outer Diameter Outside diameter of the pipe or fitting. Inner Diameter Inside diameter of the pipe or fitting. For more information, refer to Section 7.3.9 - Modifying the Fittings Database.6-68 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-69 ww ThOnce you have selected the segment type (pipe, swage, or fitting), you can specify detailed information concerning the highlighted segment. With the cursor located on a segment, click the View Segment button. When you click the View Segment button, the Pipe Fittings, Pipe Swages, or Pipe Info property view appears. The property view that appears depends on the type of Fitting/Pipe option you selected from the drop- down list. Material Select one of the available default materials or choose User Specified for the pipe section. Not required for fittings. Roughness A default value is provided based on the Pipe Material. You can specify this value. Pipe Wall Conductivity Thermal conductivity of pipe material in W/m.K to allow calculation of heat transfer resistance of pipe wall. Defaults provided for standard pipe materials are as follows: • All steel and coated iron pipes: 45.0 • Cast iron: 48.0 • Concrete: 1.38 • Wood: 0.173 • PlasticTubing: 0.17 • RubberHose: 0.151 Increments The number of increments the pipe section is divided for calculation purposes. The pipe segment report has been updated to include dedicated detail sections for both fittings and swage fittings. These sections appear in the parameters datablock. Field Description6-69 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-70 Pipe Segment ww ThViewing Segments The Pipe Info property view appears for pipe sections. On this property view, the following information is shown:. Figure 6.37 Field Description Pipe Schedule Select one of the following: • Actual. The nominal diameter cannot be specified. The inner diameter can be specified. • Schedule 40 • Schedule 80 • Schedule 160 HYSYS contains a pipe database for three pipe schedules (40, 80, 160). If a schedule is specified, a popup menu appears indicating the possible nominal pipe diameters that can be specified. Nominal Diameter Provides the nominal diameter for the pipe section. Inner Diameter For Schedule 40, 80, or 160, this is referenced from the database. For Actual Pipe Schedule, this can be specified directly by the user. Pipe Material Select a pipe material or choose User Specified. The pipe material type can be selected from the drop-down list in the field. A table of pipe materials and corresponding Absolute Roughness factors is shown in the next table. The roughness factor is automatically specified for pipe material chosen from this list. You can also specify the roughness factor manually.6-70 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-71 ww ThFitting Pressure Loss The fittings pressure loss is characterised by a two constant equation as shown below. where: A = constant, also known as velocity head factor B = constant, also known as FT factor fT = fully turbulent friction factor Roughness A default value is provided based on the Pipe Material. You can specify a value if you want. Pipe Wall Conductivity Thermal conductivity of pipe material in W/m.K to allow calculation of heat transfer resistance of pipe wall. Defaults provided for standard pipe materials are as follows: • All steel and coated iron pipes: 45.0 • Cast iron: 48.0 • Concrete: 1.38 • Wood: 0.173 • PlasticTubing: 0.17 • RubberHose: 0.151 Pipe Material Type Absolute Roughness, m Drawn Tube 0.0000015 Mild Steel 0.0000457 Asphalted Iron 0.0001220 Galvanized Iron 0.0001520 Cast Iron 0.0002590 Smooth Concrete 0.0003050 Rough Concrete 0.0030500 Smooth Steel 0.0009140 Rough Steel 0.0091400 Smooth Wood Stave 0.0001830 Rough Wood Stave 0.0009140 (6.23) Field Description K A B fT×+=6-71 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-72 Pipe Segment ww ThNote that when defining the pressure drop characteristics for a fitting, either A or B are specified, but not both. The fittings pressure loss constant K is then used to obtain the pressure drop across the fitting from the equation shown below. where: = pressure drop = density = velocity Calculation of the fully turbulent friction factor (fT) needed in the method requires knowledge of the relative roughness of the fitting. This is calculated from user entered values for roughness and fitting diameter. The Pipe Segment’s standard friction factor equation (Churchill) is then called repeatedly with the calculated relative roughness at increasing Reynolds numbers until the limiting value of friction factor is found. The pressure drop is usually described as “head loss” represented by where is commonly referred to as the “velocity head.” Looking at this equation, you will note some similarity with the pressure drop equation 6.24. Since represents the pressure drop associated with the height of a liquid column with a known density, (6.24) (6.25) (6.26) ΔP Kρν 2 2 --------= PΔ ρ ν hL K v2 2 ----⎝ ⎠ ⎛ ⎞×= v2 2 ---- ρ g hL×× ΔP ρ g hL×× ρ K v2 2 ----×× ρ K velocity head××= = =6-72 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-73 ww ThFor this reason, HYSYS calls K in this expression the “VH factor” or “velocity head factor.” It is also commonly called a K-factor or piping K-factor. In the original expression , K is sometimes defined as where: = equivilent length of the fitting in pipe diameters In general a fitting is characterised by either a velocity head factor (A) or a FT factor (B) but not both. HYSYS does not enforce this restriction however and you are free to define both factors for a fitting if required. Pipe Fittings Property View You can customize the pipe in the Pipe Fitting property view. The above property view shows a standard fitting as it would be retrieved from the fittings database. If you customize a fitting by changing either the VH Factor or FT Factor, the word User is added to the fitting name to denote the fact that it is now user defined, and the Data Source field becomes modifiable to allow you to describe the source of the new data. (6.27) Figure 6.38 K A B fT×+= K ft Leq D ---------×= Leq D --------- Refer to Section 7.3.9 - Modifying the Fittings Database for more information.6-73 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-74 Pipe Segment ww ThDefault data for FT Factor and Data Source is provided for cases retrieved from earlier versions of HYSYS. Specifically the FT Factor is set to 0.0 and the Data Source is set to “HYSYS, pre V2.3”. The VH Factor is the same as the K Factor used in earlier versions. Swage Fittings A new capability has been added to the Pipe Segment to allow the pressure drop across reductions or enlargements in the pipe line to be calculated. The feature has been added as a new fitting type called a swage. The swage fitting automatically uses the upstream and downstream pipe/fitting diameters to calculate the K factor for the fitting. Once the K factor is known the pressure loss across the reducer/enlarger can be calculated. The equations used are as follows. where: = static pressure loss = density = velocity K = reducer/enlarger K factor (6.28)ΔP Kout ρoutνout 2 2 ---------------------- ρinνin 2 2 -----------------– ρoutνout 2 2 ----------------------+= ΔP ρ ν 6-74 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-75 ww ThThe K factor from the above equation is calculated from the following equations: in the equations above is known as swage angle. Swage angle is shown in the figure below: Equations for K above are taken from Crane, Flow of Fluids, Publication 410M, Appendix A-26. For reducers where: (6.29) For enlargers where: (6.30) Figure 6.39 Kout 0.8 θ 2 -- 1 β2–( ) for θ 45°≤( ) Kout 0.5 1 β2–( ) θ 2 --sin for 45( ° θ 180° )≤<= sin= β dout din ---------= Kout 2.6 θ 2 -- 1 β2–( ) 2 sin β4 ----------------------------------------- for θ 45°≤( ) Kout 1 β2–( ) 2 β4 --------------------- for 45° θ 180°≤<( )= = β din dout ---------= θ 6-75 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-76 Pipe Segment ww ThAs stated above a swage segment automatically considers the upstream (din) and downstream (dout) diameters to work out whether the swage is a reducer or an enlarger and calculate the appropriate K value. In addition the following special cases are detected and a fixed K value is used. • The swage is the first segment in the pipe and an entrance K value of 0.5 is used. • The swage is the last segment in the pipe and an exit K value of 1.0 is used. • din = dout the swage is a simple coupling and a K value of 0.04 is used. Pipe Swages Property View A new swage fitting property view has been created to allow you to update the swage angle for a swage fitting. It also displays the upstream and downstream diameters that are used in the calculation as shown in the figure below. The automatic detection of upstream and downstream diameters by the swage segment means that there cannot be two consecutive swage segments in a pipe. This restriction is enforced by HYSYS which prevents you from specifying two adjacent segments to be swages. In addition, if two adjacent swage segments would result from deletion of an intervening pipe or fitting segment, the second swage segment is automatically converted to a default Pipe Segment. An explanatory message appears in both cases. Figure 6.406-76 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-77 ww ThRemoving a Segment To remove a segment from the Length-Elevation Profile group, select one of its parameters and click the Delete Segment button. You can remove all input from the Length-Elevation Profile group by clicking the Clear Profile button. Heat Transfer Page The Heat Transfer page is used to enter data for defining the heat transfer. The Specify By group, at the top of the property view, contains four radio buttons. Selecting one of the radio buttons displays one of the four ways of defining heat transfer: • Specified heat loss • Overall Heat Transfer Coefficient (HTC) • HTC specified by segment • Estimated HTC No confirmation is given by HYSYS before segments are removed. The radio button does not force the pipe segment to use that method of calculation – it only provides access to the property views. HYSYS works out which method to use from the data provided.6-77 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-78 Pipe Segment ww ThHeat Loss HYSYS selects the Heat Loss radio button as the default setting, when you select the Heat Transfer page for the first time. The property view appears as shown in the figure below: If the Overall heat duty of the pipe is known, the energy balance can be calculated immediately. Each increment is assumed to have the same heat loss. You enter the heat loss for the pipe in the Heat Loss field. This assumption is valid when the temperature profile is flat, indicating low heat transfer rates compared to the heat flows of the streams. This is the fastest solution method. If both inlet and outlet temperatures are specified, a linear profile is assumed and HYSYS can calculate the overall heat duty. This method allows fast calculation when stream conditions are known. Select the Heat Loss radio button to see the calculated overall heat duty. Figure 6.41 The value in the Heat Loss field is black in colour, signifying that the value was generated by HYSYS.6-78 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-79 ww ThOverall HTC When you select the Overall HTC radio button, the Heat Transfer page changes to the property view shown in the figure below. If the overall HTC and a representative ambient temperature are known, rigorous heat transfer calculations are performed on each increment. Segment HTC When you select the Segment HTC radio button, the Heat Transfer page changes to the property view shown in the figure below. Figure 6.42 Overall HTC is the overall heat transfer coefficient based upon the outside diameter of the pipe Figure 6.436-79 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-80 Pipe Segment ww ThIf the heat transfer coefficient and a representative ambient temperature are known for each segment. You can specify the ambient temperature and HTC for each pipe segment that was created on the Sizing page. HYSYS performs rigorous heat transfer calculations on each increment. Estimate HTC When you select the Estimate HTC radio button, the Heat Transfer page changes to the property view shown in the figure below. If the pipe’s HTC is unknown, you can enter information in this property view and HYSYS calculates the HTC for the pipe. Segment HTC is based upon the outside diameter of the pipe. Figure 6.44 The Overall HTC and Estimate HTC can be used together to define the heat transfer information for the pipe. If you only know the Ambient Temperature, you can supply it in the Overall HTC section and have the Overall HTC value calculated by the Estimate HTC section. Likewise, you need to specify the Ambient Temperature in the Estimate HTC section for the pipe segment to have enough heat transfer information to solve. You can select whether the ambient temperature used in the heat transfer calculations is for the entire pipe or for each segment of the pipe.6-80 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-81 ww ThInside Film Convection You can prompt HYSYS to estimate the inside film heat transfer coefficient using one of the five correlations provided. The Petukov, Dittus, and Sieder methods for calculation of inner HTC are limited to single phase applications and essentially turbulent flow only. Two and three phase systems are modeled using the single phase equations with “averaged” fluid properties. A correction for laminar flow is applied but this is not particularly effective. It is recommended that these three methods be used only for single phase pipelines operating at high Reynolds numbers (> 10000). The Profes and HTFS methods should provide much better results for two and three phase systems, and in the laminar flow region at the cost of some increase in calculation time. In general the Profes option is recommended for most pipeline applications since it takes into full account the flow regime in the pipe and is reasonably efficient in calculation. The HTFS option is more calculation intensive, particularly in two phase applications where additional flash calculations are required. It is recommended for use in cases with a high heat flux with high delta temperatures between the pipe contents and ambient conditions. The five correlations provided are: • Petukov (1970) (6.31)h k d -- f 8⁄( )RedPr 1.07 12.7 f 8⁄( )1 2⁄ Pr2 3⁄ 1–( )+ -----------------------------------------------------------------------------=6-81 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-82 Pipe Segment ww Th• Dittus and Boelter (1930) • Sieder and Tate (1936) • Profes. Implements the methods used by the Profes Pipe Simulation program (formerly PLAC). The methods are based on the Profes flow maps for horizontal and vertical flow, and appropriate correlations are used to determine the HTC in each region of the flow map. • HTFS. Implements the methods used by HTFS programs. Separate correlations are used for boiling and condensing heat transfer, and for horizontal and vertical flow. The methods used are documented in the HTFS Handbook13. where: n = (6.32) For two-phase flow: (6.33) For single phase flow: where: (6.34) h k d --0.023Red 0.8Prn= 0.4 for heating→ 0.3 for cooling→ h2-phase k d --0.027Red 0.8Pr1 3⁄ μb μw ------⎝ ⎠ ⎛ ⎞ 0.14 = h1-phase hlam( )12 h2-phase( )12+[ ] 1 12 ----- = hlam 3.66 0.0668d L -- R× e Pr 1 0.04 d L -- RePr⎝ ⎠ ⎛ ⎞ 2 3 -- + ---------------------------------------------×+= Refer to the ProFES Reference Guide for more information.6-82 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-83 ww ThYou can choose to include the pipe’s thermal resistance in your HTC calculations by selecting the Include Pipe Wall checkbox. Activating this option requires that the thermal conductivity be defined for the pipe material on the detail property view of each Pipe Segment. Default values of thermal conductivity are provided for the standard materials that can be selected in the Pipe Segment. Outside Conduction/Convection Outside convection to either Air, Water, or Ground can be included by selecting the Include Outer HTC checkbox. For air and water, the velocity of the ambient medium is defaulted to 1 m/s and is user-modifiable. The outside convection heat transfer coefficient correlation is for flow past horizontal tubes (J.P. Holman, 1989): If Ground is selected as the ambient medium, the Ground type can then be selected. The thermal conductivity of this medium appears but is also modifiable by typing over the default value. The Ground types and their corresponding conductivities are tabulated below: (6.35) Ground Type Conductivity Ground Type Conductivity Dry Peat 0.17 W/mK Frozen Clay 2.50 W/mK Wet Peat 0.54 W/mK Gravel 1.10 W/mK Icy Peat 1.89 W/mK Sandy Gravel 2.50 W/mK Dry Sand 0.50 W/mK Limestone 1.30 W/mK Moist Sand 0.95 W/mK Sandy Stone 1.95 W/mK Wet Sand 2.20 W/mK Ice 2.20 W/mK Dry Clay 0.48 W/mK Cold Ice 2.66 W/mK Moist Clay 0.75 W/mK Loose Snow 0.15 W/mK Wet Clay 1.40 W/mK Hard Snow 0.80 W/mK h k d --0.25Re0.6Pr0.38=6-83 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-84 Pipe Segment ww ThIn HYSYS, the surrounding heat transfer coefficient value is based on the following heat transfer resistance equation: where: Hsurroundings = surrounding heat transfer coefficient Rsurroundings = surrounding heat transfer resistance Zb = depth of cover to centreline of pipe ks = thermal conductivity of pipe-surrounding material (Air, Water, Ground) Dot = outer diameter of pipe, including insulation Conduction Through Insulation Conduction through the insulation or any other pipe coating can also be specified. Several representative materials are provided, with their respective thermal conductivities. You must specify a thickness for this coating. (6.36) (6.37) Insulation / Pipe Conductivity Insulation / Pipe Conductivity Evacuated Annulus 0.005 W/mK Asphalt 0.700 W/mK Urethane Foam 0.018 W/mK Concrete 1.000 W/mK Glass Block 0.080 W/mK Concrete Insulated 0.500 W/mK Fiberglass Block 0.035 W/mK Neoprene 0.250 W/mK Fiber Blanket 0.070 W/mK PVC Foam 0.040 W/mK Fiber Blanket-Vap Barr 0.030 W/mK PVC Block 0.150 W/mK Plastic Block 0.036 W/mK PolyStyrene Foam 0.027 W/mK Hsurroundings 1 Rsurroundings --------------------------------= Rsurroundings Dot 2ks ------- 2Zb 4Zb 2 Dot 2–+ Dot -------------------------------------------ln=6-84 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-85 ww Th6.4.4 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. 6.4.5 Performance Tab The Performance tab consists of the following pages: • Profiles • Slug Options • Slug Results Profiles Page The Profiles page allows you to access information about the fluid stream conditions for each specified increment in the Pipe Segment. The PF Specs page is relevant to dynamics cases only. Figure 6.45 Refer to Section 1.3.10 - Worksheet Tab for more information.6-85 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-86 Pipe Segment ww ThThe page contains a summary table for the segments which make up the Pipe Segment. The distance (length), elevation, and number of increments appear for each segment. You cannot modify the values on this page. To view the Pipe Profile property view, click the View Profile button. This view consists of a Table tab and a Plot tab. The Table tab displays the following information for each increment along the Pipe Segment: • Length • Elevation • Pressure • Temperature • Vapour Fraction • Heat Transferred • Flow Regime • Liquid Holdup • Friction Gradient • Static Gradient • Accel Gradient • Liquid Reynolds Number • Vapour Reynolds Number • Liquid Velocity • Vapour Velocity • Deposit Thickness • Deposit Volume The Plot tab graphically displays the profile data that is listed on the Table page. Select one of the radio buttons to view a profile with Length as the x-axis variable. You can modify the plot by right-clicking on the plot area, and selecting Graph Control from the object inspect menu. Refer to Section 1.3.1 - Graph Control Property View for information regarding the customization of plots.6-86 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-87 ww ThSlug Tool The Slug Tool predicts slug properties for horizontal and inclined two-phase flows in each Pipe Segment. Travelling wave solutions of the one-dimensional averaged mass and momentum equations are found and analysed to obtain slug flow properties. Stratified flow is tested for instability to small disturbances and then analysed in the unstable region to find if slug flow is possible. If large amplitude waves can bridge the pipe then slug flow is deemed to be possible. In this slug flow region a range of frequencies is possible with a maximum slug frequency occurring for slugs of zero length. Up to this maximum there is a relationship between frequency and slug length with maximum lengths occurring for the lowest frequencies. The other slug properties such as bubble length, average film holdup, slug transitional velocity, average pressure gradient can all be found over the range of allowable slug frequencies. The detailed methodology used to predict slug formation and slug properties was developed within AspenTech and is described in the paper “The modelling of slug flow properties” by M Watson19. Slug Options Page Figure 6.466-87 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-88 Pipe Segment ww ThThe entries on the Slug Options page control the models and parameters used by the slug tool in its calculations as follows: • Translational Model. You can select the option to be used for calculating the translational velocity of the slugs in the pipeline. The general form of the translational velocity is of the form: You have the option to select the Bendikson (1984) model to predict values of C0 and U0 or to select User Specified to enter values manually. • Holdup Model. You can select the option to be used to calculate the liquid holdup in the pipe. Two options are available: Gregory et. al. uses the methods published by Gregory et. al. (1978) or User Specified to enter a user defined value for the holdup fraction. • Friction Factor. Two options are available to select the friction factor model to be used in the slug tool calculations: Smooth pipe or Colebrook equation. • Frequency Option. The slug tool evaluates slug flow characteristics at a particular slug frequency. This frequency can either be predicted by the Hill & Wood correlation or specified by the user. where: c = translation velocity of slug VM = superficial velocity of two phase mixture C0, U0 = constants (6.38) c C0VM U0+=6-88 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-89 ww ThSlug Results Page The Slug Results page presents the result from the slug tool analysis as a table with the following entries. Figure 6.47 Column Description Position Distance along the pipe. Status Result of the slug calculations. Possible results are Single Phase, Stable two phase, Slug flow, Annular flow, Bubble flow or Unknown. Any error in the calculation is also reported here. Frequency Slug frequency used to calculate the slug properties. This is normally the value calculated by the Hill & Wood correlation or the user specified slug frequency according to the settings on the Slug Options page. When the correlation or user specified frequency lies outside the predicted range of slug frequencies this field shows either the minimum or maximum slug frequency which is indicated by the entry in the next column. Slug Length Average length of a slug at the indicated frequency. Bubble Length Average length of a bubble at the indicated frequency. Film Holdup Film holdup as a fraction. Velocity Translational velocity of the slug. Pressure Gradient Pressure drop over the slug/bubble unit. Slug/Bubble ratio Ratio of lengths of slug and bubble.6-89 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-90 Pipe Segment ww ThCell Details When you click the View Cell Plot button on the Slug Results page, the Cell Details property view appears. The property view shows the slug properties for a single position in the pipe across the full range of possible slug frequencies in both tabular and graphical form. A further graph shows the flow regime map for the cell indicating the region of possible slug formation at different vapour and liquid flowrates. The Next button and Previous button on the property view allow you to move along the pipe to inspect the detailed results at any point. 6.4.6 Dynamics Tab The Dynamics tab contains basic pipe parameter options to configure the pipe for Dynamics mode. Figure 6.48 Pipe unit operation does not model choking or advanced effects such as shock waves, momentum balances, and so on. To model choking and other advanced effects, use ProFES, OLGA pipe extensions, or Aspen Hydraulics flowsheet.6-90 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-91 ww ThParameters Page The Parameters page allows you to specify the pipe flow model, holdup type, and base elevation for the Dynamics mode. The following table lists and describes the objects available in the Parameters page: Figure 6.49 Object Description Simple Pipe Friction Model Method radio button Allows you to select between turbulent and full range Churchill methods to simulate the pipe flow model in Dynamics mode. The Pipe Friction Model drop-down list is only available if you select the Simple Pipe Friction Model Method radio button. Pipe Model Correlations radio button Allows you to select the pipe flow model based on the available pipe flow correlation selection from the Parameters Page in the Design tab. The calculation time for this method is long and rigorous, however, the results are more accurate. one holdup in pipe radio button Allows you to calculate the overall holdup values of the entire pipe. This method calculates the results by lumping together all the volume. The calculation time is short, however, this method is not recommended if you want to track composition (or model lag) along the pipe. one holdup per segment radio button Allows you to calculate the holdup values for each segment in the entire pipe. This method calculates and models the composition and other changes through the pipe network rigorously. The calculation time is long, however, the results are more accurate. Refer to Friction Factor section for more information.6-91 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-92 Pipe Segment ww ThHoldup Page The Holdup page contains information regarding the properties, composition, and amount of the holdup. For each phase contained within the volume space of the unit operation, the following is specified: Model Holdup Volume checkbox Allows you to calculate pipe volumes based on the pipe lengths and diameter. Generally the pipe volumes are ignored or lumped together in one vessel for the calculation, unless a model of the composition lag is required. The lumped volume approach is a simpler more robust option, and often the pressure drop result is the main interest. Having to consider many holdups with small volumes may lead to instabilities. Base Elevation of Inlet Relative to Ground field Allows you to specify the elevation of the pipe relative to the ground for Dynamics mode. Figure 6.50 Holdup Details Description Holdup No. Displays the designated number of each segment in the pipe. Number 1 indicates the first segment, number 2 indicates the second segment, and so forth. Accumulation The accumulation refers to the rate of change of material in the holdup for each phase. Moles The amount of material in the holdup for each phase. Volume The holdup volume of each phase. Object Description6-92 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-93 ww ThStripchart Page The Stripchart page allows you to select and create default strip charts containing various variable associated to the operation. 6.4.7 Deposition Tab Deposition is a general capability that can be used to model deposition of material that affects pressure drop or heat transfer to or from the pipe. Possible deposits include wax, asphaltenes, hydrates, sand, and so forth. The Deposition tab contains the following pages: • Methods • Properties • Profile • Limits HYSYS provides a model for one type of deposit namely Wax deposition modeled using the Profes methods. Other third party methods can be added as plug-in extensions. Methods Page The Methods page displays the available deposition methods. Profes Wax is the only standard one at present. Figure 6.51 Refer to Section 1.3.7 - Stripchart Page/Tab for more information. For more information about the Profes Wax method, refer to Section 7.3.8 - Profes Wax Method.6-93 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-94 Pipe Segment ww ThRegistered third party plug-in methods also appear on this page. The Profes Wax model is installed by selecting it from the Deposition Correlation list. On installation the Pipe Segment is not able to solve until the initial deposition thickness is defined on the Profile page. Once the initial deposition thickness is defined the model solves using the default values provided for the other deposition data properties. The Max. Time field allows you to specify the maximum amount of time wax deposits on the pipe. The Timestep field allows you to specify the timestep that the deposition rate is integrated over. Properties Page The Properties page allows you to specify deposit properties required by the deposition calculations. The page consists of three properties: • Density of the deposit. • Thermal Conductivity of the deposit. • Yield Strength of the deposit. When solving with its default data, the model displays a warning message in the status bar of the Pipe Segment. Figure 6.526-94 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-95 ww ThProfile Page The Profile page consists of the Deposition Profile table. This table has two purposes: • Is used to specify the initial deposition thickness, required by the deposition calculations. • Displays the profile of the deposit on the pipe. Limits Page Figure 6.53 Figure 6.546-95 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-96 Pipe Segment ww ThThe Limits page allows you to specify the maximum limits for the following parameters. • Max. Deposit Thickness • Overall Pressure Drop • Total Deposit Volume • Plug Pressure Drop • Simulation Time 6.4.8 Profes Wax Method The deposition of the wax from the bulk oil onto the pipe wall is assumed to only be due to mass transfer; shear dispersion is not considered to be a significant factor. The rate of deposition is described by: where: m’ = deposition rate (kg/s) k = mass transfer coefficient (mole/m2 s mole Fraction) C = local concentration of wax forming components (mole fraction) Mwwax = molecular weight of wax (kg/mole) A = cross-sectional area (m2) The mass transfer coefficient is calculated using the following correlation: where: Sc = (6.39) (6.40) m' k Cwall Cbulk–( )AMwwax= Sh 0.015 Re0.88× Sc 1 3 -- = μl ρlD --------6-96 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-97 ww ThRe = Sh = D = diffusivity of wax in oil (m2/s) = liquid viscosity (kg/ms) = liquid density (kg/m2) k = mass transfer coefficient (mole/m2 s mole fraction) DH = hydraulic radius (m) Vl = liquid velocity (m/s) c = liquid molar density (mole/m3) The Reynolds number that is used in these calculations is based on the local liquid velocity and liquid hydraulic radius. Physical properties are taken as the single phase liquid values. The viscosity used is based on the fluid temperature and shear rate at the wall. The difference in concentration of wax forming species between the bulk fluid and the wall, which is the driving force for the deposition of wax is obtained from calculating the equilibrium wax quantities at the two relevant temperatures. These calculations provide a wax deposition rate which is integrated over each timestep to give the total quantity of wax laid down on the pipe wall. VlρlDH μl ----------------- kDH cD ---------- μ ρl6-97 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-98 Pipe Segment ww ThProfes Wax Property View When you click the View Method button, the Profes Wax property view appears. You can change the default data in the Profes Wax model, and tune it to your specific application in this property view. The Profes Wax property view consists of three tabs: • Wax Data • Tuning Data • Ref. Comp The Calculate wax formation temperature checkbox allows you to select whether the deposition model is to calculate the initial wax formation temperature or cloud point for each pipe element when performing the deposition calculations. If activated the results appear in the Profile page of the Deposition tab. The Tune button initiates the tuning calculations and is only active when there is sufficient data to allow tuning calculation to take place. In other words, cloud point is defined, at least one temperature or wax mass percent pair is defined and reference composition defined. Wax Data Tab The Wax Data tab allows you to select the wax model to be used 6-98 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-99 ww Thfor the wax equilibrium calculations. The Wax Model drop-down list provides you with four thermodynamic models for wax formation: • Chung • Pederson • Conoco • AEA (default) Figure 6.556-99 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-100 Pipe Segment ww ThAll models are based on the following equation for the equilibrium constant, Ki, which is the ratio of concentrations of a particular component in the solid and liquid phase: where: xi = mol fraction = activity coefficient f = standard state fugacity P = pressure V = molar volume T = temperature R = gas constant S, L = denote solid and liquid phases Once the equilibrium constant for each component has been calculated, they are used to determine the quantities and composition of each phase. The differences between the various thermodynamic models depend on how the terms in the equilibrium constant equation are evaluated. The four models available in the Profes method are described by the following equations: • AEA: (6.41) (6.42) Ki xi S xi L ---- ζi Lfi L ζi Sfi S --------- Vi L Vi S– RT ------------------ 0 P ∫⎝ ⎠ ⎜ ⎟ ⎛ ⎞ P∂exp= = ζi Kiln hi fΔ RT ------- 1 T Ti f ----– ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ CpΔ R --------- 1 Ti f T ----– Ti f T ----ln+ Vi L Vi– RT ----------------- P∂ 0 P ∫+ +=6-100 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-101 ww Th• Chung: • Conoco (Erikson): • Pederson: where: = enthalpy of melting Ti f = melting temperature V = molar volume T = temperature R = gas constant = solubility parameter = heat capacity difference between solid and liquid m = denotes mixture properties i = component (6.43) (6.44) (6.45) Kiln hi fΔ RT ------- 1 T Ti f ----– ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ Vi L RT ------ δm L δi L–( ) 2 Vi L Vm ------ 1 Vi L Vm ------–+ln+ += Kiln hi fΔ RT ------- 1 T Ti f ----– ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ = Kiln Vi L δm L δi L–( ) 2 Vi S δm S δi S–( ) 2 ------------------------------- hi fΔ RT -------+ 1 T Ti f ----– ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ CpΔ R --------- 1 Ti f T ----– Ti f T ----ln++= Δhi f δ ΔCp6-101 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-102 Pipe Segment ww ThAll the models require a detailed compositional analysis of the fluid in order to be used effectively. For the Conoco model, Erickson et al proposed that the hydrocarbon analysis should distinguish between normal and non-normal paraffin components, as there is a substantial difference in melting points between these two groups. The melting temperatures make a significant impact on the predicted cloud point for any given composition. In Pederson model, the Ki values depend on the composition of the liquid and solid phases, unlike normal equilibrium calculations where the Ki s are fixed for any temperature and pressure and can lead to unstable or incorrect numerical solutions. The AEA model is the only model which incorporates a term for the effect of pressure on the liquid-solid equilibrium. The result is to counteract the increased solubility of wax forming components at high pressures which is due to more light ends entering the liquid phase. Using this model, the predicted cloud point and wax quantities can both increase or decrease with increasing pressure, depending on the fluid composition. The table allows you to select which components in the system are able to form wax. The default criteria for the components in this table are as follows: • Components with a mole weight less than 140 or inorganic component types can never form wax. The checkbox for these components is set to a grey checkbox that cannot be modified. • Hydrocarbon component types form wax. The checkbox is automatically selected for these components, but you can clear the checkbox. Hypothetical components generally fall into this category. • Other organic component types do not form wax. The checkbox is clear but you can select it. The ability to select whether a particular component forms wax gives you additional control when defining the wax formation characteristics of a system. For example, you can define two hypothetical components with common properties, and by setting one as a wax former you could vary the quantity of wax produced in the boiling range covered by the hypotheticals by varying their proportions.6-102 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-103 ww ThTuning Data Tab The Tuning Data tab allows you to define the observed wax formation characteristics of a system to tune the wax model. The Cloud Point Input field allows you to specify the temperature at which the first wax appears. In other words, the phase transition temperature between single liquid phase and the two phase wax/liquid mixture. The table of Temperature vs. Wax Mass Percent allows you to define the quantity of wax deposit observed as a function of temperature. New points can be added to the table in any order; they are sorted by temperature when the tuning process is run. To run the tuning calculations a minimum of one pair of data points is required. Up to 10 pairs of data points can be specified. Figure 6.56 To remove a point from the table both the temperature and the wax mass percent values must be deleted. Calculated values for the Cloud Point and Wax Mass Percent appear in the calculated field and column after the tuning process is run.6-103 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-104 Pipe Segment ww ThRef Comp Tab The Ref Comp tab allows you to specify the reference composition of the fluid that is used for tuning calculations. Tuning Process The tuning process is a series of calculations that is initiated as a task by clicking the Tune button. The first step validates the tuning data specified as follows: • that there is at least one component identified as a wax former. • a valid reference composition has been entered. • sorting the pairs of temperature/wax mass percent in order of descending temperature. • ensure cloud point temperature is greater than any temperature in table of temperature/wax mass percent pairs. If any problem is found the tuning process stops, and an appropriate error message appears on the tuning status bar. If the tuning data is valid then the tuning process first does a VLE flash at 15°C and 100 kPa to calculate the liquid composition of the reference stream. This is used as the base Figure 6.57 The Normalise button allows you to normalise the composition entered and setting any unspecified fractions to zero. The composition is entered in a table as either a mole or mass fraction depending on which radio button is selected.6-104 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-105 ww Thcomposition for all subsequent tuning calculations. If a liquid phase cannot be found in the reference stream at these conditions the tuning calculations fail. The tuning process then continues using an iterative least squares solution method. Progress of the tuning process is output to the main HYSYS status bar. When complete the tuning process checks for convergence and displays the result on the tuning status bar. If the tuning process converged then the calculated results on the Tuning data tab are updated. If the tuning process failed to converge the tuning parameters are set to the best values that were obtained. Tuning parameters can be reset to their original values by re-selecting the wax model. There are three tuning parameters available for the Chung, Pederson, and Conoco wax models, and four tuning parameters for the AEA model. The tuning process only attempts to tune as many parameters as is possible from the specified data (for example, cloud point + one pair of temperature/wax percent data allows tuning of two parameters, more pairs of temperature/wax percent data points are required to tune additional parameters). In cases where an attempt to tune three or four parameters fails to converge, a second tuning attempt is made automatically for just two tuning parameters. The convergence of the tuning process is checked by looking at the cloud point result since this is the most critical parameter. Generally convergence is achieved when there are one or two pairs of temperature/wax percent data. Given the emphasis placed on achieving the cloud point the calculated results for wax percent can often show greater errors, particularly when there are multiple temperature/wax percent points. You should realise that the degree to which the tuning parameters can adjust the temperature/wax percent curve predicted by the models is limited, and that hand tuning by changing the number and proportion of wax forming components in the system may be required in some cases.6-105 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-106 Pipe Segment ww Th6.4.9 Modifying the Fittings Database The fittings data base contains VH Factor and FT Factor data taken from Perry. Some of the Factor data are taken from Crane. The following table details the values in the database. The Data Source column displays the source of the data values. Description VH Factor FT Factor Swage Angle Data Source Pipe 0 0 0 Swage: Abrupt 0 0 180 Swage: 45 degree 0 0 45 Elbow: 45 Std 0 16 0 Crane 410M, A-29 Elbow: 45 Long 0.2 0 0 Perry 5th ed, Table 5-19 Elbow: 90 Std 0 30 0 Crane 410M, A-29 Elbow: 90 Long 0.45 0 0 Perry 5th ed, Table 5-19 Bend: 90, r/d 1 0 20 0 Crane 410M, A-29 Bend: 90, r/d 1.5 0 14 0 Crane 410M, A-29 Bend: 90, r/d 2 0 12 0 Crane 410M, A-29 Bend: 90, r/d 3 0 12 0 Crane 410M, A-29 Bend: 90, r/d 4 0 14 0 Crane 410M, A-29 Bend: 90, r/d 6 0 17 0 Crane 410M, A-29 Bend: 90, r/d 8 0 24 0 Crane 410M, A-29 Bend: 90, r/d 10 0 30 0 Crane 410M, A-29 Bend: 90, r/d 12 0 34 0 Crane 410M, A-29 Bend: 90, r/d 14 0 38 0 Crane 410M, A-29 Bend: 90, r/d 16 0 42 0 Crane 410M, A-29 Bend: 90, r/d 20 0 50 0 Crane 410M, A-29 Elbow: 45 Mitre 0 60 0 Crane 410M, A-29 Elbow: 90 Mitre 0 60 0 Crane 410M, A-29 180 Degree Close Return 0 50 0 Crane 410M, A-29 Tee: Branch Blanked 0 20 0 Crane 410M, A-29 Tee: As Elbow 0 60 0 Crane 410M, A-29 Coupling/Union 0.04 0 0 Perry 5th ed, Table 5-19 Gate Valve: Open 0.17 0 0 Perry 5th ed, Table 5-19 Gate Valve: Three Quarter 0.9 0 0 Perry 5th ed, Table 5-19 Gate Valve: Half 4.5 0 0 Perry 5th ed, Table 5-19 Gate Valve: One Quarter 24 0 0 Perry 5th ed, Table 5-196-106 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-107 ww ThGate Valve, Crane: Open 0 8 0 Crane 410M, A-27 Diaphram Valve: Open 2.3 0 Perry 5th ed, Table 5-19 Diaphram Valve: Three Quarter 2.6 0 0 Perry 5th ed, Table 5-19 Diaphram Valve: Half 4.3 0 0 Perry 5th ed, Table 5-19 Diaphram Valve: One Quarter 21 0 0 Perry 5th ed, Table 5-19 Globe Valve: Open 6 0 0 Perry 5th ed, Table 5-19 Globe Valve: Half 9.5 0 0 Perry 5th ed, Table 5-19 Globe Valve, Crane: Open 0 340 0 Crane 410M, A-27 Angle Valve: Open 2 0 0 Perry 5th ed, Table 5-19 Angle Valve, 45 deg: Open 0 55 0 Perry 5th ed, Table 5-19 Angle Valve, 90 deg: Open 0 150 0 Crane 410M, A-27 Blowoff Valve: Open 3 0 0 Perry 5th ed, Table 5-19 Plug Cock: Angle 5 0.05 0 0 Perry 5th ed, Table 5-19 Plug Cock: Angle 10 0.29 0 0 Perry 5th ed, Table 5-19 Plug Cock: Angle 20 1.56 0 0 Perry 5th ed, Table 5-19 Plug Cock: Angle 40 17.3 0 0 Perry 5th ed, Table 5-19 Plug Cock: Angle 60 206 0 0 Perry 5th ed, Table 5-19 Plug Cock: Open 0 18 0 Crane 410M, A-29 Butterfly Valve: Angle 5 0.24 0 0 Perry 5th ed, Table 5-19 Butterfly Valve: Angle 10 0.52 0 0 Perry 5th ed, Table 5-19 Butterfly Valve: Angle 20 1.54 0 0 Perry 5th ed, Table 5-19 Butterfly Valve: Angle 40 10.8 0 0 Perry 5th ed, Table 5-19 Butterfly Valve: Angle 60 118 0 0 Perry 5th ed, Table 5-19 Butterfly Valve: 2-8in, Open 0 45 0 Crane 410M, A-28 Butterfly Valve: 10-14in, Open 0 35 0 Crane 410M, A-28 Butterfly Valve: 16-24in, Open 0 25 0 Crane 410M, A-28 Ball Valve: Open 0 3 0 Crane 410M, A-28 Check Valve: Swing 2 0 0 Perry 5th ed, Table 5-19 Check Valve: Disk 10 0 0 Perry 5th ed, Table 5-19 Check Valve: Ball 70 0 0 Perry 5th ed, Table 5-19 Check Valve: Lift 0 600 0 Crane 410M, A-27 Check Valve: 45 deg Lift 0 55 0 Crane 410M, A-27 Foot Valve 15 0 0 Perry 5th ed, Table 5-19 Foot Valve: Poppet disk 0 420 0 Crane 410M, A-28 Foot Valve: Hinged disk 0 75 0 Crane 410M, A-28 Water Meter: Disk 7 0 0 Perry 5th ed, Table 5-19 Description VH Factor FT Factor Swage Angle Data Source6-107 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-108 Pipe Segment ww ThA few sections from the “fittings.db” file are shown below: This can be broken down, line by line: 1. FittingType elbow45std What this does is define an object “elbow45std” of type “FittingType”. “FittingType” has three members (parameters): a VH Factor (K-Factor), FT factor or Swage angle, and a description. 2. VHFactor 0.0 This is the K-Factor for the fitting. When you add a fitting to the fittings list, this is the number that is put in the K-Factor column. 3. Desc “Elbow: 45 Std” Water Meter: Piston 15 0 0 Perry 5th ed, Table 5-19 Water Meter: Rotary 10 0 0 Perry 5th ed, Table 5-19 Water Meter: Turbine 6 0 0 Perry 5th ed, Table 5-19 User Defined 0 0 0 User specified Description VH Factor FT Factor Swage Angle Data Source FittingType elbow45std VHFactor 0.0 Desc “Elbow: 45 Std” FTFactor 16.0 Data Source “Crane 410M, A-29” end FittingType swage2 VHFactor 0.0 Desc “Wage: 45 degree” Sweating 45.0 end ... FittingTypeGroup FTG AddFitt elbow45std ... end The object name “elbow45std” is only an internal name; it doesn't appear in any lists or property views.6-108 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-109 ww ThThis assigns a label (description) to the fitting “elbow45std”. It is this label that is used in the fittings window to select fittings. 4. This line contains one of the following two possible command lines: • FTFactor 16.0 This is the FT factor for the fitting. When you add a fitting to the fittings list, this is the number that is put in the FT factor column. • Swage Angle 45 This command is used to assign the value for the swage angle fitting calculation method. 5. DataSource “Crane 410M, A-29” This tells you where the data source was taken from. 6. end This tells HYSYS that the description of “elbow45std” is done. So, you have a definition of a fitting. But, that's not quite enough. All the fittings are gathered into one group - a “FittingTypeGroup”- to make it easier for HYSYS to determine what should go where. 1. FittingTypeGroup FTG Same as line 1 above. This defines an object “FTG” of type “FittingTypeGroup”. “FTG” can have many parameters, but they must all be of the same type - FittingType. The FittingTypeGroup is like a container for all the pipe fittings. 2. AddFitt elbow45std This adds the previously defined fitting to the group. Notice that the fitting MUST be defined before it is added to the group. All new fittings should be added last in the database file. When the fittings appear in the drop-down list, they are sorted alphabetically by their Desc parameter. 3. end This tells HYSYS that you have added all the fittings you want to the fitting group. Notice that HYSYS does not automatically put fittings in the group just because they are defined beforehand. 6-109 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-110 Pipe Segment ww ThFor example, if we had defined “elbow45std” as above, but forgot to add it to the fittings group, there would be no way to access it in the fittings window. Also, the “end” command is very important. If you forget to put an “end” in somewhere in the middle of the fittings.db file, you can get errors that may or may not tell you what is actually wrong. Adding a Fitting So, now you can add your own fitting. Open the “fitting.db” file in an ASCII editor and move somewhere in the middle of the file (but make sure that you are above the definition of the fittings group). Now, add the following lines: FittingType loopdeloop VHFactor 10.0 Desc “Loop-de-loop!” FT Factor 0.0 DataSource “Add fitting demo” end You have now created a fitting. You don't have to indent the VHFactor, Desc, FTFactor, and DataSource lines, it just makes for neater and easier to read files. Next, the fitting needs to be added to the fittings group. Find the line in the file that says “FittingTypeGroup FTG”. Now, go anywhere between this line and the “end” line and type the following: AddFitt loopdeloop Now all you have to do is run HYSYS and make a Pipe Segment. The new fitting “Loop-de-loop!” appears in the fittings drop- down list, and if you add a “Loop-de-loop!” to the fittings list, it comes up with a K-Factor of 10.0. New fittings should be added as the last entry in the database.6-110 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-111 ww ThTo take out the fitting, just delete the lines that were previously added. 6.5 Relief Valve The Relief Valve unit operation can be used to model several types of spring loaded Relief Valves. Relief Valves are used quite frequently in many different industries in order to prevent dangerous situations occurring from pressure buildups in a system. Its purpose is to avert situations that occur in a dynamic environment. The flow through the Relief Valve can be vapour, liquid, liquid with precipitate, or any combination of the three. 6.5.1 Relief Valve Property View There are two ways that you can add a Relief Valve to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Piping Equipment radio button. 3. From the list of available unit operations, select Relief Valve. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing the F4. 2. Double-click the Relief Valve icon. Relief Valve icon6-111 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-112 Relief Valve ww ThThe Relief Valve property view appears. 6.5.2 Design Tab The Design tab of the Relief Valve property view contains the following pages: • Connections • Parameters • User Variables • Notes Figure 6.586-112 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-113 ww ThConnections Page The Connections page is where the inlet and outlet streams of the Relief Valve are specified. The page contains the following fields described in the table below: Figure 6.59 Field Description Name The name of the Relief Valve. HYSYS provides a default designation for the unit operation, however, you can edit this name at any time by entering a new name in this field. Inlet Stream entering Relief Valve. You can either select a pre- existing stream from the drop-down list associated with this field or you can create a new stream by selecting this field and typing the stream name. Outlet Relief Valve exit stream. Like the Inlet field, you can either select a pre-existing stream from the drop-down list associated with this field or you can create a new stream by selecting this field and typing the stream name. Fluid Package Displays the fluid package associated to the relief valve. If the simulation case contains multiple fluid packages, you can open the drop-down list and select a different fluid package.6-113 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-114 Relief Valve ww ThParameters Page The Parameters page contains only two fields, which are described in the table below: User Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. Object Description Set Pressure The pressure that the Relief Valve begins to open. Full Open Pressure The pressure that the Relief Valve is fully open. Figure 6.60 For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.6-114 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-115 ww Th6.5.3 Rating tab The Rating tab contains the following pages: • Sizing • Nozzles Sizing Page On the Sizing page, you can specify the Valve Type, and the Capacity Correction Factors and Parameters. Valve Type In HYSYS, you can specify three different valve characteristics for any Relief Valve in the simulation case. If you are working exclusively in Steady State mode, you are not required to change any information on the pages accessible through the Rating tab. Figure 6.61 Valve Type Description Quick Opening A Relief Valve with quick opening valve characteristics obtains larger flows initially at lower valve openings. As the valve opens further, the flow increases at a smaller rate.6-115 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-116 Relief Valve ww ThCapacity Correction Factors and Parameters The Capacity Correction Factors and Parameters group consists of five parameters of the flow equations. You can set: • Viscosity Coefficient (KV) • Discharge Coefficient (KD) • Back Pressure Coefficient (KB) • Valve Head Differential Coefficient • Orifice Area (A) For more information on the function of these parameters, consult the following section on flow through the Relief Valve. Flow Through Relief Valve The mass flowrate through the Relief Valve varies depending on the vapour fraction and the pressure ratio across the valve. For two phase flow, the flows are proportional to the vapour fraction and can be calculated separately and then combined for the total flow. Vapour Flow In Valve For gases and vapours, flow may be choked or non-choked. If the pressure ratio is greater than the critical, the flow is NOT Linear A Relief Valve with linear valve characteristics has a flow, which is directly proportional to the valve % opening. Equal Percentage A Relief Valve with equal percentage valve characteristics initially obtains very small flows at lower valve openings. However, the flow increases rapidly as the valve opens to its full position. In the following calculation for the Relief Valve, HYSYS uses the rigorous value for k. Valve Type Description6-116 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-117 ww Thchoked: where: P1 = upstream pressure P2 = downstream pressure K = ratio of Specific Heats For Choked vapour flow, the mass flowrate is given by the following relationship: where: W = mass flow rate A = relief valve orifice area KL = capacity correction factor for valve lift KD = coefficient of discharge KB = back pressure coefficient V1 = specific volume of the upstream fluid P1 = upstream pressure K = ratio of Specific Heats For non-Choked vapour flow, the mass flowrate is given by: (6.46) (6.47) (6.48) P2 P1 ----- 2 K 1+ ------------ K K 1– ------------ ≥ W AKLKDKB P1K V1 --------- 2 K 1+ ------------ K 1+ K 1– ------------ 1 2 -- = W AKLKD P1 V1 ----- 2K K 1– ------------⎝ ⎠ ⎛ ⎞ P2 P1 -----⎝ ⎠ ⎛ ⎞ 2 K --- P2 P1 -----⎝ ⎠ ⎛ ⎞ K 1+ K ------------ – ⎝ ⎠ ⎜ ⎟ ⎜ ⎟ ⎛ ⎞ 1 2 -- = 6-117 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-118 Relief Valve ww ThLiquid Flow In Valve Liquid Flow through the valve is calculated using the following equation: where: W = mass flow rate A = relief valve orifice area KL = capacity correction factor for valve lift KD = coefficient of discharge KV = viscosity correction factor P1 = upstream pressure P2 = downstream pressure K = ratio of Specific Heats = density of upstream fluid Capacity Correction Factor (KL) The Capacity Correction Factor for back pressure is typically linear with increasing back pressure. The correct value of the factor should be user-specified. It may be obtained from the valve manufacturer. The capacity correction factor for valve lift compensates for the conditions when the Relief Valve is not completely open. (6.49)W AKLKDKV 2 P1 P2–( )ρ1[ ] 1 2 -- = ρ16-118 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-119 ww ThIncreasing-sensitivity valves have the following flow characteristics: Linear and decreasing-sensitivity valves have the following flow characteristics: where: The valve head differential term allows for customization of the flow characteristics with respect to stem travel. Its value can range between 0 and 1. Nozzles Page The Nozzles page contains information regarding the elevation and diameter of the nozzles. (6.50) (6.51) (6.52) KL L2 a 1 a–( )L4+[ ] 1 2⁄ --------------------------------------------= KL L a 1 a–( )L2+[ ] 1 2⁄ --------------------------------------------= a valve head differential a maximum flow valve head differential at zero flow ----------------------------------------------------------------------------------------------= Refer to Section 1.3.6 - Nozzles Page for more information.6-119 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-120 Relief Valve ww Th6.5.4 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. 6.5.5 Dynamics Tab The Dynamics tab contains the following pages: • Specs • Holdup • Advanced • Stripchart Specs Page The PF Specs page is relevant to dynamics cases only. If you are working exclusively in Steady State mode, you are not required to change any information on the pages accessible through the Dynamics tab. Figure 6.62 Refer to Section 1.3.10 - Worksheet Tab for more information.6-120 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-121 ww ThThe Specs page consists of two groups: • Dynamic Parameters This group consists of three parameters. Parameter Descriptions Delta P Pressure drop across the valve. Valve Lift The Relief Valve lift. It is calculated using one of the two following formulas: If inlet pressure is increasing: (6.53) where: P1 = upstream pressure POPEN = set pressure PFULL = full open pressure If inlet pressure is decreasing: (6.54) where: P1 = upstream pressure PRESEAT = reseating pressure PCLOSE = closing pressure Percentage Open The Valve Lift in percentage. L P1 POPEN– PFULL POPEN– --------------------------------------= L P1 PRESEAT– PCLOSE POPEN– ------------------------------------------=6-121 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-122 Relief Valve ww Th• Hysteresis Parameters When the Enable Valve Hysteresis checkbox is selected, the Hysteresis Parameters group appears. This group contains two fields, which are described in the table below: Holdup Page The Holdup page contains information regarding the holdup properties, composition, and amount. Advanced Page The fail-safe function in Relief Valve is used to prevent pipeline and equipment from physical damages due to escalation in pressure. The plant operator can either apply this feature to relief the pressure built-up from affecting other parts of the plant or it can be used in their training to simulate valve stickiness or failure. Field Descriptions Closing Pressure Pressure that the valve begins to close after reaching the full lift pressure. In other words, the value entered in the full pressure field on the Parameters page of the Design tab. Reseating Pressure The pressure that the valve reseats after discharge. Each unit operation in HYSYS has the capacity to store material and energy. Typical Valves usually have significantly less holdup than other unit operations in a plant. Therefore, the volume of the Valve operation in HYSYS is defaulted to be zero. For more information, refer to the valve operation Holdup Page in the Dynamics tab.6-122 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-123 ww ThThe Relief Valve has five fail modes. The way that these fail modes interact with the relief valve is somewhat different from the ones of the control valve discussed in Chapter 1.6.3 - Control Valve Actuator of the HYSYS Dynamic Modeling guide. To activate the relief valve fail mode option, ensure that the Integrator is running with HYSYS Dynamics license. To set the Relief Valve in fail state, you can select the Valve has Failed checkbox on the Advanced page. You can now specify one of the following fail modes: • None. Relief valve operates as it is designed to be (same as the operating condition when the Valve has Failed checkbox is not active). • Fail Open. The valve lift completely opens. The valve lift remains at maximum opening position even when the inlet pressure is not longer above the opening (set) pressure. The Relief Valve continues to fully open until it is reset. • Fail Shut. The valve lift completely closes. The valve life stays shut even when the inlet pressure is above the opening (set) pressure. The Relief Valve remains fully shut until it is reset. • Fail Hold. Allows you to simulate the valve lift stickiness by holding the valve lift to the last failed position. The Relief Valve lift will not move even when the inlet pressure is no longer above the opening pressure. • Fail Specified. Allows you to manually specify the fail position when the Relief Valve has failed. The fail position is expressed in terms of percentage of the valve opening, and it is used to define the amount of valve lift. Figure 6.63 Refer to Chapter 1.6 - HYSYS Dynamics in the HYSYS Dynamic Modeling guide for more information. 6-123 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-124 Tee ww ThStripchart Page The Stripchart page allows you to select and create default strip charts containing various variable associated to the operation. 6.6 Tee The Tee operation splits one feed stream into multiple product streams with the same conditions and composition as the feed stream, and is used for simulating pipe tees and manifolds. The dynamic Tee operation functions very similarly to the steady state Tee operation. However, the enhanced holdup model and the concept of nozzle efficiencies can be applied to the dynamic Tee. Flow reversal is also possible in the Tee depending on the pressure-flow conditions of the surrounding unit operations. 6.6.1 Tee Property View There are two ways that you can add a Tee to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property views property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Piping Equipment radio button. 3. From the list of available unit operations, select Tee. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the Tee icon. Refer to Section 1.3.7 - Stripchart Page/Tab for more information. Tee icon6-124 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-125 ww ThThe Tee property view appears. 6.6.2 Design Tab The Design tab contains the following pages: • Connections • Parameters • User Variables • Notes Connections Page On the Connections page, you can specify the feed stream, any number of product streams (all of which are automatically assigned the conditions and composition of the feed stream), and the fluid package associated to the Tee operation. Figure 6.646-125 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-126 Tee ww ThThe only difference among the product streams is the flow rate, determined by the flow ratios, which you specify on the Parameters page (Steady State mode) or the outlet valve openings, which you specify on the Dynamics page (Dynamic mode). Parameters Page For steady state calculations, specify the desired flow ratio (the ratio of the outlet stream flow to the total inlet flow). You can toggle between ignoring or acknowledging when a negative flow occurs by selecting the Warn on Negative Flow checkbox. Figure 6.65 Figure 6.666-126 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-127 ww ThA flow ratio is generally between 0 and 1; however, a ratio greater than one can be given. In that case, at least one of the outlet streams have a negative flow ratio and a negative flow (backflow). For N outlet streams attached to the Tee, you must specify N-1 flow ratios. HYSYS then calculates the unknown stream flow ratio and the outlet flow rates. where: ri = flow ratio of the ith stream fi = outlet flow of the ith stream F = feed flow rate N = number of outlet streams Figure 6.67 (6.55) (6.56) With the Warn on Negative Flow checkbox selected, the status bar is yellow when negative flow occurs. With the Warn on Negative Flow checkbox clear, the status bar is green when negative flow occurs. ri 1 i= N ∑ 1.0= ri fi F ---=6-127 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-128 Tee ww ThFor example, if you have four outlet streams attached to the Tee, you must give three flow ratios and HYSYS calculates the fourth. If you switch to Dynamic mode, the flow ratio values do not change if the values are between 0 and 1 (they are equal to the dynamic flow fractions). User Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. Figure 6.68 F 1 3 2 . . . . . N f1 f2 f3 fN • Inlet flow F • N outlet streams • Specify N-1 flow ratios ri • Outlet stream flows f1 = r1F For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.6-128 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-129 ww Th6.6.3 Rating tab You need HYSYS dynamics to specify any rating information for the Tee operation. Nozzles Page The Nozzles page contains information regarding the elevation and diameter of the nozzles. It is strongly recommended that the elevation of the inlet and exit nozzles are equal for this unit operation. If you want to model static head, the entire piece of equipment can be moved by modifying the Base Elevation relative to the Ground Elevation field. 6.6.4 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. 6.6.5 Dynamics Tab The Dynamics tab contains the following pages: • Specs • Holdup • Stripchart The PF Specs page is relevant to dynamics cases only. If you are working exclusively in Steady State mode, you are not required to change any information on the pages accessible through the Dynamic tab. Refer to Section 1.3.6 - Nozzles Page for more information. Refer to Section 1.3.10 - Worksheet Tab for more information.6-129 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-130 Tee ww ThSpecs Page The dynamic specifications of the Tee can be specified on the Specs page: If the Use Splits as Dynamic Flow Specs checkbox is selected, the exit flows streams from the Tee are user-defined. You can define the molar flow for each exit stream by specifying the specific valve openings for each exit stream from the Tee. This situation is not recommended since the flow from the Tee is determined from split fractions and not from the surrounding pressure network of the simulation case. If this option is used, the valve opening fields should be specified all Tee exit streams. In addition a single pressure and single flow specification are required by the PF solver. Figure 6.69 In Dynamic mode, there are two specifications you can choose to characterize the Tee operation.6-130 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-131 ww ThIf the Use Splits as Dynamic Flow Specs checkbox is inactive, the flow rates of the exit streams are determined from the pressure network. If this option is set, the dynamic Tee acts similar to a Mixer set with the Equalize All option. The “one PF specification per flowsheet boundary stream” rule applies to the Tee operation if the Use Splits checkbox is inactive. It is strongly recommended that you clear the Use Splits checkbox in order to realistically model flow behaviour in your dynamic simulation case. Reverse flow conditions can occur in the Tee operation if the Use Splits checkbox is inactive. If flow reverses in the Tee, it acts essentially like a dynamic Mixer with the Equalize All option. In dynamics, these two unit operations are very similar. Holdup Page Each unit operation in HYSYS has the capacity to store material and energy. Typical Tees in actual plants usually have significantly less holdup than other unit operations in a plant. Therefore, the volume of the Tee operation in HYSYS cannot be specified and is assumed to be zero. Since there is no holdup associated with the Tee operation, the holdup’s quantity and volume are shown as zero in the Holdup page. Figure 6.70 Refer to Section 1.3.3 - Holdup Page for more information. 6-131 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-132 Tee ww ThThe Disable flashes checkbox enables you to turn on and off the rigorous flash calculation for the tee. This feature is useful if the PFD has a very large number of tees, and you do not care whether the contents of the streams around them are fully up to date or not, or you prefer maximum speed in the simulation calculation. • To turn off the flash calculation, select the Disable flashes checkbox. If the flash calculations are turned off, the outlet stream will still update and propagate values, but the phase fractions and temperatures may not be correct. • To turn the flash calculation back on, clear the Disable flashes checkbox. The default selection is to leave the flash calculation on. Stripchart Page The Stripchart page allows you to select and create default strip charts containing various variable associated to the operation. HYSYS recommend that the flash calculations be left on, as in some cases disabled flash calculation can result in instabilities or unexpected outcomes, depending on what is downstream of the unit operation where the flash has been turned off. This feature should only be manipulated by advanced users. Refer to Section 1.3.7 - Stripchart Page/Tab for more information.6-132 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-133 ww Th6.7 Valve HYSYS performs a material and energy balance on the inlet and exit streams of the Valve operation. HYSYS performs a flash calculation based on equal material and enthalpy between the two streams. It is assumed that the Valve operation is isenthalpic. The following is a list of variables that can be specified by the user in the Valve operation. • Inlet temperature • Inlet pressure • Outlet temperature • Outlet pressure • Valve Pressure Drop A total of three specifications are required before the Valve operation solves. At least one temperature specification and one pressure specification are required. HYSYS calculates the other two unknowns. There are also a number of new features that are available with the Valve operation. The Valve is a basic building block in HYSYS dynamic cases. The new Valve operation models control valves much more realistically. The direction of flow through a Valve is dependent on the pressures of the surrounding unit operations. Like the steady state Valve, the dynamics Valve operation is isenthalpic. Some of the new features in the Valve operation include: • A pressure-flow specification option that realistically models flow through the valve according to the pressure network of the plant. Possible flow reversal situations can therefore be modeled. • A pipe segment contribution that can model pressure losses caused by an attached pipe’s roughness and diameter. • A new valve equation that incorporates static head and frictional losses from the valve and/or pipe segment. • A model incorporating Valve dynamics such as the stickiness in the valve and dynamic behaviour in the actuator.6-133 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-134 Valve ww Th• Different valve types such as linear, equal percentage, and quick opening valves. • Built-in sizing features that determine valve parameters used in the valve equation. The total valve pressure drop refers to the total pressure difference between the inlet stream pressure and the exit stream pressure. The total pressure drop across the Valve is calculated from the frictional pressure loss of the Valve, and the pressure loss from static head contributions. 6.7.1 Valve Property View There are two ways that you can add a Valve to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Piping Equipment radio button. 3. From the list of available unit operations, select Valve. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the Valve icon. Valve icon6-134 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-135 ww ThThe Valve property view appears. 6.7.2 Design Tab The Design tab contains the following pages: • Connections • Parameters • User Variables • Notes Figure 6.716-135 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-136 Valve ww ThConnections Page The Connections page allows you to specify the name of the operation, as well as the inlet stream and outlet stream. Parameters Page The pressure drop of the Valve operation can be specified on the Parameters page. Figure 6.72 Figure 6.736-136 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-137 ww ThUser Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. 6.7.3 Rating Tab The Rating tab contains the following pages: • Sizing • Nozzles • Options Sizing (dynamics) Page The Sizing (dynamics) page contains the following elements: • Valve Manufacturer group • Valve Type group • Sizing Conditions group • Valve Operating Characteristics group • Sizing Methods group If you are working exclusively in Steady State mode, you are not required to change any information on the pages accessible through the Rating tab. For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.6-137 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-138 Valve ww Th• Size Valve button Valve Manufacturer Group The Valve Manufacturers group contains a drop-down list that allows you to select the valve manufacturer type/equation model. The figure on the left, displays all the manufacturers available in HYSYS. • Masoneilan • Mokveld • Fisher. This equation model is based on the test program results from Fisher Controls International, Inc. (developed the equation in 1963). This model accurately predicts the flow for either high or low recovery valves, for any gas and under any service conditions. • Introl • Valtek • CCI Drag • Universal Gas Sizing. This equation model is very similar to the Fisher equation. The difference between the two is the backwards compatibility when the valve has both vapour and liquid flowing through. The Universal Gas Sizing model uses the overall density for the vapour. Future versions of HYSYS will allow you to select the density model. Figure 6.746-138 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-139 ww Th• Simple resistance equation. This equation model treats the flow as always being proportional to the square root of the pressure drop. No choking is modelled. This equation is often used when a simple model is desired, or if you want to calculate and update the equation constant. Valve Type Group Some of the valve manufacturers also provide different types of valves for you to choose from. This group is only available if the selected valve manufacturer provides multiple valve types. The following table lists the currently supported valve manufacturers and their associated valve type: Valve Manufacturer Valve Type Masoneilan • DP Globe: V-Port • SP Globe: flow to open • Control Ball • Globe: contoured • Split Body: flow to open • Split Body: flow to close • 40000,41000 Series • Camflex: flow to close • Camflex: flow to open • Butterfly (Minitork) • Gobe: flow to close Mokveld • RZD-R • RZD-RES • RZD-RVX • RZD-REVX • RZD-RCX Introl • Series 60A • Series 60 • Series 10 HF • Series 20 H • Series 10 HFD • Series 20 HFD • Series 10 flow to open • Series 20 flow to open • Series 10 flow to close • Series 10 HFT • Series 20 HFT Valtek • Vector One 60 deg • Vector One 90 deg • Dragon Tooth • Mark One flow to open • Mark Two flow to open • Mark One flow to close • Mark Two flow to close Valve Type group6-139 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-140 Valve ww ThSizing Conditions Group HYSYS uses the stream conditions provided in the Sizing Conditions group to calculate valve parameters, which are used in the valve equation. This group contains two radio buttons and a table. • Current radio button. Allows you to view and modify the current variable values for the valve sizing conditions. The current variable values are calculated based on the stream flow rate and HYSYS default values provided in the table. • User Input radio button. Allows you to view and modify the variable values for the valve sizing conditions. The variable values are calculated based on the values you provide in the table. The table contains the following cells: Cell Description Inlet Pressure Displays the inlet pressure of the fluid flowing through the valve. This value cannot be modified. Molecular Weight Displays the molecular weight of the fluid flowing through the valve. This value cannot be modified. Valve Opening Allows you to modify the percentage opening of the valve. Delta P Allows you to specify the pressure difference in the valve. Flow Rate Allows you to modify the mass flow rate of the fluid flowing through the valve. You can only modify the mass flow rate, if you select the User Input radio button.6-140 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-141 ww ThValve Operating Characteristics Group The Valve Operating Characteristics group contains four radio buttons. To select the method to characterize the valve: 1. In the Valve Operating Characteristics group, select the method you want to use by clicking the appropriate radio button: Linear, Quick Opening, Equal Percentage, and User Table. If you select Linear, Quick Opening, or Equal Percentage: 2. In the Sizing Methods group, select Cv or Cg radio button and specify the parameter values in the appropriate cells. If you select User Table: 3. In the Valve Operating Characteristics group, click the View button. The valve Characteristics Curve property view appears. 4. In the Lift (% of max) column, specify the percentage of the valve opening. This percentage value is based on the maximum valve opening. 5. In the Flow (% of max) column, specify the flow rate percentage. This percentage value is based on the maximum fluid flow rate through the valve. Object Description Linear radio button Allows you to select Linear method to calculate the valve size. Quick Opening radio button Allow you to select Quick Opening method to calculate the valve size. Equal Percentage radio button Allows you to select Equal Percentage method to calculate the valve size. User Table radio button Allows you to specify the valve characteristics curve values used to calculate the valve size. When selected, a View button appears. The View button gives you access to the Characteristics Curve property view. Refer to Theory section for more information about each calculation method. Refer to Sizing Methods Group section for more information. Refer to Characteristics Curve Property View section for more information.6-141 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-142 Valve ww ThCharacteristics Curve Property View The Characteristics Curve property view contains a table, two buttons, and a plot: When you first open the Characteristics Curve property view, the Lift (% of max) and Flow (% of max) columns contain two mandatory values (0 and 1.0) and three default values (0.25, 0.5, and 0.75). Control Valve Calculation Theory In HYSYS there are four different methods to characterize the control valve. All four methods use the following parameters to calculate the control valve. The flow rate through a control valve depends on the actual valve position. If the flow can be expressed in terms of %Cv (e.g., 0% representing no flow conditions and 100% representing the maximum flow conditions), then the valve characteristics of a control valve are defined as the dependence of the quantity of %Cv on the actual valve percent opening. Object Description Lift (% of max) column Allows you to specify the valve stem position percentage value. The values are limited to a range of 0 to 100. Flow (% of max) column Allows you to specify the percentage flow rate associated to the valve stem position. The values are limited to a range of 0 to 100. Erase Selected button Allows you to erase the selected percentage stem position and percentage flow rate values. Erase All button Allows you to erase all the values in the Curve Information table. Plot Displays the characteristics curve based on the values specified in the Curve Information table. The table must contain at least three points to calculate the characteristics curve of the valve operation. If the values in the Curve Information table is not valid and the User Table method has been selected, then you will not be able to run the valve in dynamic mode.6-142 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-143 ww ThThree methods use equation models based on three different types of valves: Valve Type Description Linear A control valve with linear valve characteristics has a flow which is directly proportional to the valve % opening. The mathematical relationship of Cv (%) and Valve Position (%) for Linear valve is as follows: (6.57) Quick Opening A control valve with quick opening valve characteristics obtains larger flows initially at lower valve openings. As the valve opens further, the flow increases at a smaller rate. The mathematical relationship of Cv (%) and Valve Position (%) for Quick Opening valve is as follows: (6.58) Equal Percentage A control valve with equal percentage valve characteristics initially obtains very small flows at lower valve openings. However, the flow increases rapidly as the valve opens to its full position. The mathematical relationship of Cv (%) and Valve Position (%) for Equal Percentage valve is as follows: (6.59) %Cv %Valve Opening= %Cv 100 ------------ (%Valve Opening/100)0.5= %Cv 100 ------------ (%Valve Opening/100)3=6-143 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-144 Valve ww ThThe inherent valve characteristics are shown graphically in the figure below. The fourth method uses a table filled with values of the valve stem positions and the associated percentage flow capacity characteristic curves to calculate the operating characteristics. In other words, the fourth method does not rely on an equation to predict the control valve flow characteristics, instead it relies on values supplied by the user. The calculation is done by using simple quadratic interpolation from the three points in the table closest to the current stem position. Figure 6.75 0 20 40 60 80 100 0 20 40 60 80 100 Quick Opening Linear Equal Percentage % Valve Position % C v CONTROL VALVE FLOW CHARACTERISTICS6-144 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-145 ww ThSizing Methods Group The Sizing Methods group contains four radio buttons and a table. Two radio buttons pertain to parameter manipulation: Two radio buttons pertain to the sizing method: The table lists the available parameters: Object Description Cv radio button Allows you to select Cv as the parameter to manipulate the resistance equation in the flow calculation. Cg radio button Allows you to select Cg as the parameter to manipulate the resistance equation in the flow calculation. Object Description Fisher Universal Uses the pre-HYSYS 2006.5 sizing method for valve sizing. ANSI/ISA Uses the industry-standard ANSI/ISA S75.01 for valve sizing. The ANSI/ISA valve sizing option is not activated when the user selects either the Universal Gas Sizing or Simple Resistance Equation option from the Valve Manufacturers drop-down list. Object Description C1 Allows you to specify the ratio value of Cg/Cv. Km Allows you to specify the pressure recovery coefficient. This coefficient is used in choked liquid flow calculations. Cv Allows you to specify the fluid flow rate (Cv) value. This cell is only active if you select Cv radio button. Cg Allows you to specify the gas sizing coefficient. This cell is only active if you select Cg radio button. k Allows you to specify the k value for the Simple Resistance equation method. This cell is only available if you select Simple resistance equation in the Valve Manufacturer group. Fl Allows you to specify the liquid pressure recovery factor. This cell is only available if you select the ANSI/ISA sizing method.6-145 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-146 Valve ww ThSizing Theory HYSYS supports two sizing calculation methods - the old Fisher- based method, and the new ANSI/ISA sizing calculations. The essential difference (with the exception of the Simple Resistance Equation) in the old sizing method lies in the constants and equations that are employed in calculating the flow rate within the valve. The new ANSI/ISA procedure employs the same set of flow equations for all manufacturers and valve types. The difference between manufacturers, valve types, style and trim using the ANSI/ISA method is only reflected in the vendor- calibrated constants in the global sizing equations (Xt, Fl, and Fp). The difference between the manufacturers and types is the equations and constants used to calculate the flow rate within the valve. All valve manufacturers and types have Cv and Cg methods to calculate flow rate. Fisher Universal Sizing Method The following equations provide an example of the sizing method calculation for Fisher Sizing valve: • The Cv- and Cg-based flow equation calculates the vapor flow through the valve using the following equation: Fp Allows you to specify the piping geometry factor. This cell is only available if you select the ANSI/ISA sizing method. Xt Allows you to specify the terminal pressure drop. This cell is only available if you select the ANSI/ISA sizing method. Size Valve button Allows you to specify a single valve parameter, while HYSYS calculates the remaining parameter values based on the stream and valve conditions (the conditions are taken from the Sizing Conditions group). HYSYS provides a C1 default value of 25. (6.60) Object Description f lb hr⁄( ) υfracfac1.06Cg ρ lb ft⁄ 3( ) P1× 59.64 C1 ------------ 1 P2 P1 -----– cpfac× ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ sin×=6-146 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-147 ww Thwhere: P1 = pressure of the inlet stream P2 = pressure of the exit stream without static head contributions = 1, outlet molar vapour fraction vfrac > 0.1 = 0, outlet molar vapour fraction vfrac = 0 = vfrac/0.1, otherwise • For the liquid flow through the valve, the equation is as follows: HYSYS reports the full Cv (at 100% open, which remains fixed) plus the valve opening. If the Valve is 100% open, then you get a smaller Valve than if the Valve was only 50% open for the same conditions. This is just one way of sizing a Valve, as some sources report an effective Cv (varies with the valve opening) versus the value opening. (6.61) (6.62) (6.63) (6.64) (6.65) The above equations are not rigorous for two-phase flow. C1 Cg Cv -----= Km 0.001434C1= cpfac 0.4839 1 2 1 γ+ -----------⎝ ⎠ ⎛ ⎞ γ γ 1– ----------⎝ ⎠ ⎛ ⎞ – ---------------------------------------= γ Cp Cv⁄= υfracfac f lb hr⁄( ) 1 υ– fracfac〈 〉 63.338× C× v ρ lb ft⁄ 3( )× P1 P2–×=6-147 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-148 Valve ww ThANSI/ISA Sizing Method The ANSI/ISA sizing method implements the industry standard ANSI/ISA S75.01 for valve sizing. The ANSI/ISA is generally considered state-of-the-art in valve sizing and more accurate than the old Fisher-based sizing equations. The ANSI/ISA sizing procedure introduces three new vendor- specific parameters to size a valve for a given application: • Piping geometry factor, Fp • Terminal pressure drop ratio, XT • Liquid pressure recovery factor, Fl The Fl and XT parameters are functions of the valve type, trim style, and flow direction that are supplied by the valve manufacturer. The general flow equation for a two-phase flow is given by: where: Pu = the upstream pressure Pd = the downstream pressure vfrac = the weight fraction of vapor of total flow Cv = the flow coefficient f = the flow rate = the specific weight at inlet conditions in lb/ft3 Y = the gas expansion factor The ANSI/ISA valve sizing option is not activated when the user selects either the Universal Gas Sizing or Simple Resistance Equation option from the Valve Manufacturers drop-down list. (6.66) uuvp duvphrIb psiaPxYCFvfrac PPftIbCFvfracf γ ρ ).(.****338.63* *)/(***338.63*)0.1( 3 / +−−= γ 6-148 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-149 ww ThThe gas expansion factor Y is calculated using: where: x = the pressure drop ratio, The piping geometry factor (Fp) in the general flow equation is a dimensionless quantity that approximates the influence of pipe fittings, reducers, or increasers that are connected to the valve. For example, Fp is equal to 1 if the diameters of the inlet and outlet pipes are equal. The default value of Fp is 1.0 in HYSYS. In cases where the valve inlet and outlet diameters are different, obtain the Fp value from the valve manufacturer’s catalog. The liquid pressure recovery factor (Fl) corresponds to Km in the Fisher-based sizing method. It indicates the amount of pressure recovery between the valve’s vena-contracta and the outlet stream. Generally, the higher the value of the liquid pressure recovery factor, the greater the pressure drop that can be accommodated by the valve before the inception of choked flow condition. HYSYS sets the allowable pressure drop based on the calculated pressure drops at the choked and service conditions. The pressure drop at choked or critical flow for liquid flow is estimated using: where: FF = the liquid critical pressure ratio, (6.67) Note that for choked flow condition, FkXT is used in place of x in Equation (6.66) and Equation (6.67). (6.68) Y 1.0 x 3.0FkXT --------------------–= Pu Pd– Pu ----------------- PchokedΔ Fl 2 Pu FFPv–( )= 0.96 0.28 Pv Pc -----–6-149 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-150 Valve ww ThPv = the vapor pressure of the liquid at the flow temperature Pc = the liquid critical pressure The pressure drop at service condition is given by: The lower of and is employed as the allowable pressure drop for liquid flow valve sizing. XT is the equivalent of the Fl factor in valve sizing for compressible fluids, i.e., gas and steam flow. The pressure drop ratio for compressible flow at service condition is given by: Note that the allowable pressure drop ratio is limited to the terminal pressure drop ratio, XT, which is given by: where: Fk = k = the ratio of specific heats, In HYSYS, XT is set to a default value of 0.7. (6.69) (6.70) (6.71) Except for slight differences in nomenclature and procedures, the ANSI/ISA S75.01 is generally compatible with the formulations of IEC-534-2 (International Electrotechnical Commission) for valve sizing. PΔ Pu Pd–= PchokedΔ PΔ x Pu Pd– Pu -----------------= x FkXT= k 1.4 ------ cp cv ----6-150 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-151 ww ThValve Vapor Flow Models The dropdown box of Valve Manufacturers is only used for sizing vapor/gas flows. This section summarizes the major gas flow equations for 6 valve manufacturers • Masoneilan • Mokveld • Fisher • Introl • Valtek • CCI Drag plus the two phase flow calculations for the Handle multi- phase flows rigorously option. The following common variables are applied to all 6 valve manufacturers. Input: Pu = upstream pressure (bara) Pd = downstream pressure (bara) Cv = valve input coefficient - effective opening of the valve (metric) Output: Fv = vapor or gas mass flowrate (kg/hr) Valve Vapor/Gas Flow Equations Given upstream and downstream pressures and an effective valve Cv, HYSYS Dynamics calculates the vapor/gas mass flowrates using flow equations appropriate to the valve manufacturer. HYSYS Dynamics uses a general liquid flow equation (Fisher Liquid Flow Equation) to calculate the liquid phase applications for all valve types: (6.72)pcv %Cv 100 -----------=6-151 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-152 Valve ww ThIf pcv > 1.0, then set pcv = 1.0 Masoneilan The parameters: a, b, c, d, e will depend on the valve types. (6.73) (6.74) (6.75) Valve Type Parameters DP GLOBE : V-PORT a = 0.998 b = 0.1179 c = 0.2632 d = 0.2583 e = 0.09324 40000, 41000 SERIES a = 0.9989 b = 0.2620 c = 0.5573 d = 0.6765 e = 0.3059 SP GLOBE: FLOW-TO- OPEN a = 0.9986 b = 0.3776 c = 0.833 d = 0.9673 e = 0.4137 CAMFLEX: FLOW-TO- OPEN a = 0.9985 b = 0.5354 c = 0.9630 d = 0.9487 e = 0.3729 SPLIT BODY: FLOW-TO- OPEN a = 0.9917 b = 0.9523 c = 2.543 d = 3.474 e = 1.646 G Mw 28.96⁄= ΔP Pu Pd–= Cf a b pcv c pcv2 d pcv3 e pcv4×+×–×+×–=6-152 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-153 ww ThTo see if the valve has a critical flow: If Y < 1.5, then it is a non-critical flow. CAMFLEX: FLOW-TO- CLOSE a = 0.9982 b = 0.5302 c = 0.3471 d = 0.2068 e = 0.07264 BUTTERFLY (MINITORK) a = 0.9060 b = 0.5169 c = 0.3805 d = 0.1185 e = 0.00000298 CONTROL BALL a = 0.9187 b = 0.2269 c = -0.6245 d = -0.6672 e = -0.1311 SPLIT BODY: FLOW-TO- CLOSE a = 0.5439 b = 0.7677 c = 7.184 d = 12.14 e = 5.944 GLOBE: CONTOURED a = 0.6308 b = 0.5227 c = 6.545 d = 11.36 e = 5.626 GLOBE: FLOW-TO-CLOSE a = 0.5470 b = 0.9956 c = 8.523 d = 13.73 e = 6.526 (6.76) Valve Type Parameters Y 1.63 ΔP Pu⁄ Cf --------------------------------=6-153 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-154 Valve ww ThIf Y >= 1.5, it is a critical flow; set Y = 1.5. Mokveld The parameters: a, b, c, d, e will depend on the valve types. (6.77) (6.78) (6.79) Valve Type Parameter RZD-R a = 0.9929 b = 2.805 c = 6.916 d = 7.639 e = 3.030 RZD-RES a = 0.891 b = 1.427 c = 2.826 d = 2.785 e = 1.049 RZD-RVX a = 0.6918 b = 2.563 c = 9.101 d = 12.03 e = 5.244 temp 0.397771 27.32 C× v Cf Mw××× G t 273.15+( )× z× --------------------------------------------------------------------------------= Fv temp Pu Y 0.148Y3· –⎝ ⎠ ⎛ ⎞××= Cf a b pcv c pcv2 d pcv3 e pcv4×+×–×+×–=6-154 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-155 ww ThTo see if it is critical flow: If , then it is a non-critical flow. If , it is a critical flow; set Y = 1.5.. Fisher This method is based on the Fisher valve equation. RZD-REVX a = 0.9512 b = 1.212 c = 3.197 d = 3.661 e = 1.456 RZD-RCX a = 0.9275 b = -0.0001306 c = -0.4872 d = -0.3888 e = -0.04661 (6.80) (6.81) (6.82) (6.83) Valve Type Parameter Y 1.63 ΔP Pu⁄ Cf --------------------------------= Y 1.5< Y 1.5≥ temp 0.392666 27.32 C× v Cf×× Mw× G t 273.15+( )× z× --------------------------------------------------------------------------------= Fv temp Pu Y 0.148Y3· –⎝ ⎠ ⎛ ⎞××= vk1 0.0004444 Mw t 273.15+( )⁄ 1.0e 6–+ · = 6-155 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-156 Valve ww ThIf Pr > 1.0 – 1e-6, then Pr = 1.0 – 1e-6. If vk2 > 3.14159/2.0 (or ), then a sonic flow occurs (it is a critical flow), and vk2 is limited to /2. Introl The parameters: a, b, c, d, e will depend on the valve types. (6.84) (6.85) (6.86) (6.87) Valve Type Parameter 1. SERIES 10 FLOW-TO- OPEN a = 0.9993 b = 0.325 c = 0.5843 d = 0.5971 e = 0.2389 2. SERIES 20 FLOW-TO- OPEN&CLOSE a = 0.5331 b = -1.086 c = -0.03679 d = 2.082 e = 1.407 3. SERIES 10 FLOW-TO- CLOSE a = 0.5049 b = -0.1387 c = 4.115 d = 7.965 e = 4.076 Pr Pd Pu -----= vk2 59.6379 C1⁄( ) 1.0 Pr–= π 2⁄ π Fv vk1 Cv Pu vk2sin C1 3600×××××= Cf a b pcv c pcv2 d pcv3 e pcv4×+×–×+×–=6-156 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-157 ww Th4. SERIES 60A a = 0.9184 b = 0.1115 c = -0.5018 d = -0.1855) e = 0.1311 5. SERIES 60 a = 0.9194 b = 0.07341 c = -1.228 d = -1.403; e = -0.4458 6. SERIES 10 HF a = 1.0 b = 0.0 c = 0.0 d = 0.0 e = 0.0 7. SERIES 20 H a = 1.0 b = 0.0 c = 0.0 d = 0.0 e = 0.0 8. SERIES 10 HFD a = 1.0 b = 0.0 c = 0.0 d = 0.0 e = 0.0 9. SERIES 20 HFD a = 1.0 b = 0.0 c = 0.0 d = 0.0 e = 0.0 10. SERIES 10 HFT a = 1.0 b = 0.0 c = 0.0 d = 0.0 e = 0.0 11. SERIES 20 HFT a = 1.0 b = 0.0 c = 0.0 d = 0.0 e = 0.0 Valve Type Parameter6-157 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-158 Valve ww ThTo calculate pressure drop limit: To see if it is critical flow: If P > dPlimit, then it is a critical flow; set P = dPlimit. Otherwise, it is a non-critical flow. (6.88) (6.89) (6.90) (6.91) Fk cpcv 1.4 -----------= dPlimit bar_cf2 Fk introlR Pu×××= Δ Δ temp S2– Fk S2 ---------= Kx S1 1 ΔP Pubar_cf2 -----------------------– ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ temp = 6-158 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-159 ww ThIf Kx < 1.0, set Kx = 1.0 Finally, calculate the gas flow: Valtek The parameter Xt depends on the valve types. Valve Type Parameters For single stage trims from valve types of 1) to 7) bar_cf = 1.33 * Cf introlR = 0.47 S1 = 1.0 S2 = 0.65 S3 = 0.92 If Kx > 1.6, then set Kx = 1.6 VHfactor = 1.0 For two stage trims from valve types of 8) and 9) bar_cf = 1.18 * Cf introlR = 0.65 S1 = 0.97 S2 = 0.53 S3 = 0.90 If Kx > 1.8, then set Kx = 1.8 VHfactor = 1.0 + 0.33 * P / Pu For three stage trims from valve types of 10) and 11) bar_cf = 1.11 * Cf introlR = 0.75 S1 = 0.90 S2 = 0.60 S3 = 1.0 If Kx > 2.0, then set Kx = 2.0 VHfactor = 1.0 + 0.48 * P / Pu (6.92) Valve Type Value of Xt MARK ONE FLOW-TO- OPEN 0.75 MARK TWO FLOW-TO- OPEN 0.75 MARK ONE FLOW-TO- CLOSE 0.70 MARK TWO FLOW-TO- CLOSE 0.70 Δ Δ Fv 0.994053VHfactor Kx⁄ Cv× 27.32× ΔP Dvap× 1.0e 6–+×=6-159 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-160 Valve ww ThTo check for choked flow: If Pu > 1.0e-6: xp = P/Pu If < 1.0e-6, then xp =1 .0e-6 If , then xp = xt * Fk If xp > xt * Fk, then it is critical flow; set xp = xt * Fk. If Fk < 1.0e-6, set Fk = 1.0e-6. If xt < 1.0e-6, set xt = 1.0e-6. If z < 0.1, set z = 0.1. VECTOR ONE 60 DEG 0.38 VECTOR ONE 90 DEG 0.20 DRAGON TOOTH 1.0 (6.93) (6.94) (6.95) Valve Type Value of Xt Fk cpcv 1.4 -----------= Δ xp Pu 1.0e 6–≤ y 1.0 Xp 3FRXt ---------------–= Fv 3.464= C1× Cv× 27.32× Pu× Y× xp Mw× z t 273.15+( ) ------------------------------- 1.0e 6–+×6-160 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-161 ww ThCCI Drag If z < 0.1, set z = 0.1. Fk = cpcv / 1.4 If Fk < 1.0e-6, set Fk = 1.0e-6. If Pu > 1.0e-6 xp = P / Pu Y = 1.0 - Otherwise, xp = 0.0 and Y = 1.0. where: open% = Percent of valve opening pcv = Fraction of rated Cv Mw = Molecular weight of vapor phase from upstream G = Parameter = Mw / 28.96 P = Pressure drop Pu = Upstream pressure (bara) Pd = Downstream pressure (bara) Cf = Valve critical flow factor Y = Gas expansion factor temp, vk1, vk2 = Temporary variables Cv = Valve flow coefficient C1 = Cg/Cv , a parameter input which is a function of body size of valve and line size t = Vapor phase temperature from upstream (C) (6.96) Δ xp 3.0Fk ------------- Fv 3.453134= C1× Cv× 27.32× Mw t 273.15+( ) z 1.0e 6–+× ----------------------------------------------------------- Y Pu× xp××× Δ 6-161 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-162 Valve ww Thz = Upstream compressibility factor in vapor phase Fv = Vapor or gas flowrate (kg/hr) Pr = Pressure ratio of Pd/Pu Fk = cpcv/1.4 cpcv = Rigorous Cp/Cv, ratio of specific heats dPlimit = Pressure drop limit bar_cf, introlR, S1, S2, and S3 = Parameters used in valve equations Kx = Expansion correction factor VHfactor = Reheat factor, depending on the number of stage trim Dvap = Mass density in vapor phase (kg/m3) Xt = Pressure drop ratio factor (valve specific) xp = Ratio of pressure drop to inlet press “Handle multi-phase flows rigorously” option This process will iteratively be calculated until full convergence to final Ftotal. Fm = f (Vgas) is a function of Vgas, which is based on the following data: Vgas [15]= {0, 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, .85, 0.9, .925, 0.95, 0.99,1} Fm [15] = {0, 0.092, 0.184, 0.276, 0.371, 0.469, 0.576, 0.711, 0.876, 0.965, 1.0, 0.980, 0.91, 0.50, 0} Cvr = (Cvl + Cvg) * (1.+ Fm) = (Cv + Cg/C1) * (1. + Fm) αl Fl Cv⁄= αv Fv C1 Cg⁄×= Vmf Vf Mw v Vf Mw v× 1 Vf–( ) Mw l×+( )⁄×= Vgas Vmf Dvap⁄ Vmf Dvap⁄ 1 Vmf–( ) Dliq⁄+( )⁄=6-162 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-163 ww ThIf Vmf = 0, then Ftotal = * Cvr If Vmf = 1.0, then Ftotal = * Cvr Otherwise, where: Fl = Mass flow for liquid phase Fv = Mass flow for vapor phase, same as Fv above developed by different valve manufacturers Cv = Standard liquid sizing coefficient Cg = Cg for gas phase C1 = Cg/Cv ratio for valve Cvl = Cv for liquid phase, Cvl = Cv Cvg = Cv required for gas phase = Cg/C1 Cvr = Cv required for mixture flow Vmf = Vapor mass fraction Vf = Vapor molecular fraction Mw v = Vapor molecular weight Mw l = Liquid molecular weight , - Parameters Denom = Denominator of and Vgas = Gas volume ratio Fm = Cv correction factor, a function of the gas volume ratio Dvap = Mass density of vapor phase Dliq = Mass density of liquid phase Ftotal = Overall mass flowrate Denom αv 1 Vmf–( )× αl Vmf×+= αl αv Ftotal αv αl Cvr Denom 1 Fm+( )⁄⁄××= αl αv αl αv6-163 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-164 Valve ww ThSimple Resistance Equation If the Simple Resistance Equation is chosen, you can either: • Specify k value. • Have k calculated from the stream and valve conditions displayed in the Sizing Conditions group. To calculate k value, specify the required variable values and click the Size Valve button. The Simple Resistance Equation method calculates the flow through the Valve using the following equation: The general valve flow equation uses the pressure drop across the Valve without any static head contributions. The quantity, P1 - P2, is defined as the frictional pressure loss, which is used in the valve sizing calculation. The valve opening term is dependant on the type of Valve and the percentage that it is open. For a linear valve: The inverse relationship between the percentage of valve opening, and Cg can be shown as follows: When the valve size is fixed, the percentage of valve opening increases with the flow through the valve. However, when sizing a valve, the Cg is not fixed. The Cg is inversely dependent on the flow, and the percentage of valve opening. (6.97) (6.98) (6.99) f k density valveopening× P1 P2–( )×= valveopening % valve open 100 --------------------------------⎝ ⎠ ⎛ ⎞ 2 = % valve open( ) Cg× Flow=6-164 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-165 ww ThNozzles Page The Nozzles page contains information regarding the elevation and diameter of the nozzles. Options Page The Options page enables you to select the method to handle multiphase streams. • The Handle densities for multi-phase systems rigorously checkbox enables the valve to use the phase densities to calculate flow rate for the vapour and liquid. If the option was not selected the overall density is used. • The Handle multi-phase flows rigorously checkbox enables the valve to use rigorous calculation method and obtain better accuracy of the flow rates and pressure drop for both vapour and liquid flow. The calculations have been improved to be consistent with the Fisher calculations for multiphase systems. Figure 6.76 Refer to Section 1.3.6 - Nozzles Page for more information.6-165 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-166 Valve ww Th6.7.4 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. 6.7.5 Dynamics Tab The Dynamics tab contains the following pages: • Specs • Pipe • Holdup • Actuator • Flow Limits • Stripchart The PF Specs page is relevant to dynamics cases only. If you are working exclusively in Steady State mode, you are not required to change any information on the pages accessible through the Dynamics tab. Refer to Section 1.3.10 - Worksheet Tab for more information.6-166 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-167 ww ThSpecs Page The dynamic specifications and parameters of the Valve can be specified on the Specs page. Dynamic Specifications If the Total Delta P checkbox is selected, a set pressure drop is assumed across the Valve operation. With this specification, the flow and the pressure of either the inlet or exit stream must be specified or calculated from other operations in the flowsheet. The flow through the Valve is not dependent on the pressure drop across the Valve. If the Pressure Flow Relation checkbox is selected, two of the following pressure-flow specifications must either be specified or calculated by the other unit operations in the flowsheet: • Inlet Stream Pressure • Exit Stream Pressure • Flow through the Valve Figure 6.77 In Dynamic mode, there are two possible dynamic specifications you can choose to characterize the Valve operation.6-167 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-168 Valve ww ThThe flow rate through the Valve is calculated from the valve equation, and the pressure of the streams entering and exiting the Valve. In dynamics, the suggested mode of operation for the Valve is the Pressure Flow specification. The pressure drop option is provided for steady state compatibility mostly, and to allow difficult simulations to converge more easily. However, it usually is not a sensible specification since it allows a pressure drop to exist with zero flow. Dynamic Parameters The Dynamic Parameters group lists the same stream and valve conditions required to size the Valve as in the Sizing Conditions group. The Valve Opening % and the Conductance (Cv or k) appear and can be modified in the section. The conductance of the Valve can be calculated by clicking the Size Valve button. The Check Valve checkbox can be selected if you do not want flow reversal to occur in the Valve.6-168 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-169 ww ThPipe Page The Valve module supports a pipe contribution in the pressure flow equation. This can be used to model a pipe segment in the feed to the Valve, but it is also possible to disable the valve contribution and have the Valve unit operation act as a simple pipe segment only. The pressure flow specification has to be enabled in order for the pipe segment to be modeled. The following pipe modeling parameters appear in this section: Figure 6.78 A pipe contribution DOES NOT contribute to any holdup volume. You have to enter the holdup separately in the Holdup Page. The pipe calculations for a valve are not rigorous for multiphase flow and are only approximations. • Friction Factor Equation • Material • Roughness • Pipe length • Feed diameter • Darcy friction factor • Pipe k • Velocity • Reynolds number6-169 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-170 Valve ww ThFriction Factor The Friction Factor Equation option allows you to choose between two different equations: • Assume Complete Turbulence (f is fixed) Assume Complete Turbulence is the default equation, and the calculation is fast and simple. This method calculates the friction factor once and uses that value irrespective of the Reynolds number (the calculated friction factor value is not correct if the flow is laminar). • Full-Range Churchill (covers all flow regimes)1,7 The Full-Range Churchill method calculates the friction factor as a function of the Reynolds number. This method is slower but calculates a unique friction factor for the turbulent, lamiar, and transtitional regions. If the flow through the Valve is too low HYSYS uses a low limit of 10 for the Reynolds number. HYSYS suggests a typical pipe roughness if the pipe material is specified. The pipe roughness may also be directly specified. The feed diameter and pipe length must be specified as well. These specifications are used to determine the Darcy friction factor. The friction factor is calculated as follows: where: fDarcy = Darcy friction factor D = pipe diameter = pipe roughness Assume Complete Turbulence equation: (6.100) Full-Range Churchill equation: (6.101) (6.102) 1 ffriction --------------------- 2.457 3.707D ε -----------------⎝ ⎠ ⎛ ⎞ln= ffriction 8 Re ------⎝ ⎠ ⎛ ⎞ 12 1 A B+( )1.5 -----------------------+ 1 12⁄ = fDarcy 8 ffriction×= ε 6-170 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-171 ww ThA pipe k-value is calculated from the Darcy friction factor and the pipe diameter. The pipe k value is incorporated into the general valve equation. Notice that this pipe k is independent of the flow rate or pressure of the fluid in the Valve. Holdup Page The Holdup page contains information regarding the holdup properties, composition, and amount. The pipe segments only calculate frictional losses. They do not automatically calculate holdup volume. You must enter this on the Holdup page of the Dynamics tab. Figure 6.79 Each unit operation in HYSYS has the capacity to store material and energy. Typical Valves usually have significantly less holdup than other unit operations in a plant. Therefore, the volume of the Valve operation in HYSYS is defaulted to be zero. A 2.457 1 7 Re ------⎝ ⎠ ⎛ ⎞ 0.9 0.27 ε D ---⎝ ⎠ ⎛ ⎞+ ---------------------------------------------ln 16 = B 37530 Re --------------⎝ ⎠ ⎛ ⎞ 16 = Refer to Section 1.3.3 - Holdup Page for more information. 6-171 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-172 Valve ww ThThe Holdup page allows you to: • Specify a non-zero value (in the Holdup Volume field) for the holdup volume in the Valve. • Disable any flashes that may occur in the Valve. The Disable flashes checkbox enables you to turn on and off the rigorous flash calculation for the valve. This feature is useful if the PFD has a very large number of valves, and you do not care whether the contents of the streams around them are fully up to date or not, or you prefer maximum speed in the simulation calculation. • To turn off the flash calculation, select the Disable flashes checkbox. If the flash calculations are turned off, the outlet stream will still update and propagate values, but the phase fractions and temperatures may not be correct. • To turn the flash calculation back on, clear the Disable flashes checkbox. The default selection is to leave the flash calculation on. The HYSYS Dynamics license is required and the Access Fidelity license options checkbox selected in the Options tab of the Integrator property view, to set a non-zero holdup. Holdup occurs after the valve, whereas the pipe contribution occurs before the valve. HYSYS recommend that the flash calculations be left on, as in some cases disabled flash calculation can result in instabilities or unexpected outcomes, depending on what is downstream of the unit operation where the flash has been turned off. This feature should only be manipulated by advanced users. Refer to Section 2.4 - Integrator in the HYSYS Dynamic Modeling guide for more information.6-172 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-173 ww ThActuator Page The Actuator page allows you to model valve dynamics in the Valve operation. The HYSYS Dynamics license is required to use the Actuator features found on this page. Flow Limits Page The Flow Limits page allows you to monitor the status of the vapour and liquid flow passing through the valve. The page consists of two groups: • Vapour Choking • Liquid Choking Vapour Choking Group By default, the Vapour Choking status is always monitored whenever it is applicable. You can view the current condition of the vapour flow in the Vapour Choking Status group. The active status is shown in black whereas the inactive status is greyed out. The two statuses available are Critical Flow and No Choking. Critical flow or vapour choking refers to the crowding condition when the gas flowing through the valve has exceeded the designed limit and reaches the sonic velocity. Figure 6.80 Refer to Section 1.6.3 - Control Valve Actuator in the HYSYS Dynamic Modeling guide for more information.6-173 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-174 Valve ww ThCritical flow is calculated by the Fisher equation for gases. where: f = flow (lb/hr) Vfrac = vapour fraction Cg = Fisher’s valve vapour coefficient C1 = critical flow factor, Cg/Cv (between 33 - 38) Cpfac = theoretical correction factor for the ratio of specific heats = density (lb/ft3) P1 = pressure at valve inlet (psia) P2 = pressure at valve outlet (psia) As the Sine function approaches to 1, the flow through the valve becomes choked and under this condition, the vapour through the valve undergoes critical flow. (6.103)f Vfrac 1.06 Cg ρ P1 59.64 C1 ------------ 1 P2 P1 ------–× Cpfac × ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ sin×××××= ρ 6-174 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-175 ww ThLiquid Choking Group Liquid choked modeling is optional in HYSYS. You can turn it on or off for the associated valve by selecting the Model Liquid Choking checkbox. The Liquid Choking Status group contains three flow conditions: • No choking. Normal flow condition. An increase in pressure drop across the valve results in an increased flow. The No choking condition holds for a limited range. • Flashing. When the pressure of the valve outlet falls below the vapour pressure of the liquid. • Cavitating. When the pressure of valve outlet raises above the vapour pressure of the liquid. The presence of these flow conditions can significantly affect the valve performance and the overall process. During flashing, liquid starts to vapourize, and the change in phase from liquid to vapour causes bubbles to form. This creates congestion across the valve (liquid choking), and the flow is severely limited. At this point, increase in pressure drop will not result in increased flow. When cavitation occurs, the pressure of the liquid recovers and raises above its vapour pressure. This causes vapour bubbles to collapse and burst, producing a great amount of noise and vibrations that can damage the valve. Figure 6.81 You can also select the Model Liquid Choking checkbox on the Options tab of the Integrator property view.6-175 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-176 Valve ww ThSince the regular Fisher liquid flow equation does not predict liquid choked flow, a different equation is used to take into account the effects of flashing and cavitation. Km (the pressure recovery coefficient) predicts flashing and cavitation for a valve. By default, the pressure recovery coefficient is set at a conservative value of 0.9. You can specify the Km value to adjust the flow condition. The liquid choked-flow condition is shown in Figure 7.73. As pressure drop increases, the liquid flow becomes choked. The allowable pressure drop ( ) indicates when the liquid choked-flow occurs and it is defined as: where: Km = pressure recovery value rc = critical pressure ratio Pv = vapour pressure of liquid Figure 6.82 (6.104) q, g pm ΔP Flow equation prediction ΔPallowable ΔPmax Choked flow ΔPallowable ΔPallowable Km P1 rcPv–( )=6-176 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-177 ww ThThe values of these parameters are displayed in the table. The Frictional Delta P shows the current pressure drop across the valve. As you adjust the pressure recovery coefficient, the Frictional Delta P allowable changes according to Equation (7.60). The Liquid Vapour pressure and the Critical Pressure Ratio are also displayed for reference. No message is displayed when the flow consists of vapour and liquid. Figure 6.83 If the Frictional Delta P allowable is below the Frictional Delta P, then cavitation occurs. Figure 6.84 If the flow is vapour dominant, HYSYS displays this message even if the Model Liquid Choking checkbox is selected.6-177 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-178 References ww ThStripchart Page The Stripchart page allows you to select and create default strip charts containing various variable associated to the operation. 6.8 References 1 American Gas Association on the "Engineering Data Book SI Volume II", 11th edition, GPSA, 1998, page 17. 2 Aziz, K., Govier, G.A., and Fogarasi, M., Pressure Drop in Wells Producing Oil and Gas, Journal of Canadian Petroleum Technology, July-September 1972, pp 38-48. 3 Baxendell, P.B., and Thomas, R., The Calculation of Pressure Gradients in High-Rate Flowing Wells, J. Pet. Tech., October 1961, pp 1023-1028. 4 Beggs, H.D., and Brill, J.P., A Study of Two-Phase Flow in Inclined Pipes, J. Petrol. Technol., p. 607, May (1973). 5 Brill, J.P., and Beggs, H.D., Two Phase Flow in Pipes, Sixth Ed, July 1989. 6 Brill, J.P., and Mukherjee, H., Multiphase Flow in Wells, SPE Monograph, Volume 17. 7 Churchill, S. W., Chem. Eng., 84(24), (1977), 91. 8 Duns, H.Jr., and Ros, N.C.J., Vertical Flow of Gas and Liquid Mixtures in Wells, 6th World Petroleum Congress, Frankfurt, June 1963, pp 451-465. 9 Eckert, E.R.G. & Drake, R.M., “Analysis of heat and mass transfer”, HTFS Reference Number 60167, 1972. 10Gregory, G.A., Mandhane, J. and Aziz, K., Some Design Considerations for Two-Phase Flow in Pipes, J. Can. Petrol. Technol., Jan. - Mar. (1975). 11Hagedorn, A.R., and Brown, K.E., Experimental Study of Pressure Gradients Occurring During Continuous Two-Phase Flow in Small- Diameter Vertical Conduits, Journal of Petroleum Technology, April 1965, pp 475-484. 12HTFS Handbook, Volume 2, Methods TP3, TM4, TM5 13HTFS Handbook, Volume 2, Two Phase Flow. Refer to Section 1.3.7 - Stripchart Page/Tab for more information.6-178 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Piping Operations 6-179 ww Th 14Multiphase Flow and Subsea Separation. Special report by Smith Rea Energy Associates and UKAEA, April 1989. 15Orkisewski, J., Predicting Two-Phase Pressure Drops in Vertical Pipe, Journal of Petroleum Technology, June 1967, pp 829-839. 16Poettmann, F.H., and Carpenter, P.G., The Multiphase Flow of Gas, Oil and Water Through Vertical Flow Strings with Application to the Design of Gas-Lift Installations, Drill and Prod. Practice, API, pp. 257-317, March 1952. 17Smith, R.A. et al, Two Phase Pressure Drop, HTFS Design Report 28 (Revised), 1981 (8 parts, 2 Appendices). 18Tengesdal, J.Ø, Sarica, C., Schmidt, Z., and Doty, D., A Mechanistic Model for Predicting Pressure Drop in Vertical Upward Two-Phase Flow, Journal of Energy Resources Technology, March 1999, Vol 121. 19Watson, M., The modelling of slug flow properties, 10th International Conference Multiphase '01, Cannes, France, 13-15 June 2001.6-179 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 6-180 References ww Th6-180 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-1 ww Th7 Optimizer Operation7-1 7.1 Optimizer ....................................................................................... 2 7.1.1 General Optimizer Property View ................................................ 3 7.1.2 Configuration Tab ..................................................................... 4 7.2 Original Optimizer.......................................................................... 5 7.2.1 Variables Tab ........................................................................... 6 7.2.2 Functions Tab .......................................................................... 7 7.2.3 Parameters Tab ........................................................................ 9 7.2.4 Monitor Tab ........................................................................... 11 7.2.5 Optimization Schemes ............................................................ 12 7.2.6 Optimizer Tips ....................................................................... 17 7.3 Hyprotech SQP Optimizer............................................................. 18 7.3.1 Hyprotech SQP Tab................................................................. 19 7.4 MDC Optim................................................................................... 23 7.5 DataRecon ................................................................................... 24 7.6 Selection Optimization ................................................................. 24 7.6.1 Selection Optimization Tab....................................................... 24 7.6.2 Selection Optimization Tips...................................................... 34 7.7 Example: Original Optimizer ........................................................ 35 7.7.1 Optimizing Overall UA ............................................................. 40 7.8 Example: MNLP Optimization ....................................................... 44 7.8.1 NLP Setup ............................................................................. 50 7.8.2 MINLP Setup.......................................................................... 55 7.9 References................................................................................... 59 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-2 Optimizer ww Th7.1 Optimizer HYSYS contains a multi-variable steady state Optimizer. Once your flowsheet has been built and a converged solution has been obtained, you can use the Optimizer to find the operating conditions which minimize (or maximize) an Objective Function. The object-oriented design of HYSYS makes the Optimizer extremely powerful, since it has access to a wide range of process variables for your optimization study. The Optimizer owns its own Spreadsheet for defining the Objective Function, as well as any constraint expressions to be used. The flexibility of this approach allows you, for example, to construct Objective Functions which maximize profit, minimize utilities or minimize Exchanger UA. The following terminology is used in describing the Optimizer. The Optimizer is available for steady state calculations only. The operation does not run in Dynamic mode. Terms Definition Primary Variables These are the variables imported from the flowsheet whose values are manipulated in order to minimize (or maximize) the objective function. You set the upper and lower bounds for all of the primary variables, which are used to set the search range, as well as for normalization. Objective Function The function which is to be minimized or maximized. There is a great deal of flexibility in describing the Objective Function; primary variables can be imported and functions defined within the Optimizer Spreadsheet, which possesses the full capabilities of the main flowsheet spreadsheet. Constraint Functions Inequality and Equality Constraint functions can be defined in the Optimizer Spreadsheet. An example of a constraint is the product of two variables satisfying an inequality (for example, -A*B RHS, LHS < RHS, LHS = RHS) in the Cond column. The Constraint Function is multiplied by the Penalty Value in the Optimization calculations. If you find that a constraint is not being met, increase the Penalty Value; the higher the Penalty Value, the more weight that is given to that constraint. The Penalty Value is equal to 1 by default. The current values of the Objective Function and the left and right sides of the Constraint Function cells appear in their respective fields. The Functions tab is only available if you select the Original configuration. To open the Optimizer Spreadsheet, click the SpreadSheet button. The BOX, Mixed, and SQP Methods allow for Inequality Constraints. Only the SQP Method incorporates Equality Constraints. For information on using the Spreadsheet, refer to Chapter 5 - Logical Operations.7-8 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-9 ww Th7.2.3 Parameters Tab The Parameters tab is used for selecting the Optimization Scheme and defining associated parameters. The following table contains a description of each parameter available. Figure 7.5 The Parameters tab is only available if you select the Original configuration. Parameters Description Scheme You can select the scheme type from the drop-down list. Maximum Function Evaluation Sets the maximum number of function evaluations (not to be confused with the maximum number of iterations). During each iteration, the relevant portion of the flowsheet is solved several times, depending on factors such as the Optimization Scheme, and number of primary variables. Primary Variables are normalized. Tolerance HYSYS determines the change in the objective function between iterations, as well as the changes in the normalized primary variables. Using this information, HYSYS determines if the specified tolerance is met. Refer to Section 7.2.5 - Optimization Schemes for more information about the schemes. xnorm x xlow– xhigh xlow– ---------------------------=7-9 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-10 Original Optimizer ww ThMaximum Iteration The maximum number of iterations. Calculations stop if the maximum number of iterations is reached. All of the methods except the BOX method use derivatives. Maximum Change/ Iteration The maximum allowable change in the normalized primary variables between iterations. For instance, assume the maximum change per iteration is 0.3 (this is the default value). If you have specified molar flow as a primary variable with range 0 to 200 kgmole/hr, then the maximum change in one iteration would be (200)(0.3) or 60 kgmole/hr. Shift B ensures that the Shift interval xShift never be zero. Shift A/ Shift B Derivatives of the objective function and/or constraint functions with respect to the primary variables are generally required and are calculated using numerical differentiation. The numerical derivative is calculated from the following relationship: where: x = perturbed variable (normalized) xshift = shift interval (normalized) Derivatives are calculated using: where: y2 = value of the affected variable corresponding to x + xshift y1 = value of the affected variable corresponding to x Prior to each step, the Optimizer needs to determine the gradient of the optimization surface at the current location. The Optimizer moves each primary variable by a value of xshift (which due to the size of Shift A and Shift B be a very small step). The derivative is then evaluated for every function (Objective and Constraint) using the values for y at the two locations of x. From this information and the Optimizer history, the next step direction and size are chosen. In general, it should not be necessary to change Shift A and Shift B from their defaults. Some Schemes move all Primary variables simultaneously, while others move them sequentially. Parameters Description xshift ShiftA∗x ShiftB+= ∂y ∂x ----- y2 y1– xshift ---------------=7-10 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-11 ww Th7.2.4 Monitor Tab The Monitor tab displays the values of the objective function, primary variables, and constraint functions during the Optimizer calculations. New information is updated only when there is an improvement in the value of the Objective Function. The constraint values are positive if inequality constraints are satisfied and negative if inequality constraints are not satisfied. To determine each derivative, a variable evaluation must be made in addition to the main flowsheet evaluation which is done after each iteration (main step change). Therefore, if there are two primary variables, there are three function evaluations for every iteration. If you have selected the Mixed Optimizer Scheme, the BOX and SQP methods are used in sequence - this is the reason why the Function Evaluations are reset part way through the calculations. Figure 7.6 The Monitor tab is only available if you select the Original configuration. Parameters Description7-11 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-12 Original Optimizer ww Th7.2.5 Optimization Schemes The following sections describe the Optimization schemes for the Original Optimizer. Function Setup The Optimizer manipulates the values of a set of primary variables in order to minimize (or maximize) a user-defined objective function, constructed from any number of process variables. where: x1,x2,...,xn = process variables Each primary variable, x0, can be manipulated within a specified range: where: xi = a process variable used to define the Objective Function = a primary variable which is manipulated by the Optimizer yi = a variable used to define the Constraint Function (7.2) In general, the primary variables should not be part of the Objective Function. (7.3) min f x1 x2 x3 ... xn, , , ,( ) xi LowerBound 0 xi 0 xi UpperBound 0 with i< < 1 ... j, ,= xi 0 7-12 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-13 ww ThThe general equality and inequality constraints are: The constraint functions should generally not use the primary variables. All primary variables are normalized from the lower bound through the upper bound. Thus, reasonable lower and upper bounds must be specified. Exceedingly high or low variable bounds should obviously be avoided as they may result in numerical problems when scaling. An initial starting point must be specified, and it should be within the feasible region. Constraints are optional and are not supported by all of the Optimization Schemes. If HYSYS fails to evaluate the objective function or any of the constraint functions, the Optimizer reduces the incremental step of the last primary variable by a half. The flowsheet is then recalculated. If the function evaluation is still unsuccessful, the optimization stops. By default, the Optimizer is set up to minimize the objective function. A Maximize radio button is provided on the Functions tab if you want to maximize an objective function. Internally the Optimizer simply reverses the sign. (7.4) HYSYS recommends users to manually manipulate the primary variables to get a feel for the appropriate boundaries. Use the Data Recorder or Case Study tool for this purpose. ci y1 y2 y3 ... yn, , , ,( ) 0,= i 1 ... m1, ,= ci y1 y2 y3 ... yn, , , ,( ) 0,≤ with i m1 1 ... m2, ,+= ci y1 y2 y3 ... yn, , , ,( ) 0,≥ i m2 1 ... m, ,+= Refer to Section 11.7 - Databook in the HYSYS User Guide.7-13 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-14 Original Optimizer ww ThBOX Method The procedure is loosely based on the “Complex” method of BOX1; the Downhill Simplex algorithm of Press et al2 and the BOX algorithm of Kuester and Mize.3 The BOX method is a sequential search technique which solves problems with non-linear objective functions, subject to non- linear inequality constraints. No derivatives are required. It handles inequality constraints but not equality constraints. The BOX method is not very efficient in terms of the required number of function evaluations. It generally requires a large number of iterations to converge on the solution. However, if applicable, this method can be very robust. Procedure: 1. Given a feasible starting point, the program generates an original “complex” of n+1 points around the centre of the feasible region (where n is the number of variables). 2. The objective function is evaluated at each point. The point having the highest function value is replaced by a point obtained by extrapolating through the face of the complex across from the high point (reflection). 3. If the new point is successful in reducing the objective function, HYSYS tries an additional extrapolation. Otherwise, if the new point is worse than the second highest point, HYSYS does a one-dimensional contraction. 4. If a point persists in giving high values, all points are contracted around the lowest point. 5. The new point must satisfy both the variable bounds and the inequality constraints. If it violated the bounds, it is brought to the bound. If it violated the constraints, the point is moved progressively towards the centroid of the remaining points until the constraints are satisfied. 6. Steps #2 through #5 are repeated until convergence. The BOX Method only handles inequality constraints.7-14 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-15 ww ThSQP Method The Sequential Quadratic Programming (SQP) Method handles inequality and equality constraints. SQP is considered by many to be the most efficient method for minimization with general linear and non-linear constraints, provided a reasonable initial point is used and the number of primary variables is small. The implemented procedure is based entirely on the Harwell subroutines VF13 and VE174. The program follows closely the algorithm of Powell5. It minimizes a quadratic approximation of the Lagrangian function subjected to linear approximations of the constraints. The second derivative matrix of the Lagrangian function is estimated automatically. A line search procedure utilizing the “watchdog” technique (Chamberlain and Powell6) is used to force convergence. Mixed Method The Mixed method attempts to take advantage of the global convergence characteristics of the BOX method and the efficiency of the SQP method. It starts the minimization with the BOX method using a very loose convergence tolerance (50 times the desired tolerance). After convergence, the SQP method is then used to locate the final solution using the desired tolerance. The Mixed Method handles inequality constraints only.7-15 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-16 Original Optimizer ww ThFletcher Reeves Method The procedure implemented is the Polak-Ribiere modification of the Fletcher-Reeves conjugate gradient scheme. The approach closely follows that of Press et al2, with modifications to allow for lower and upper variable bounds. This method is efficient for general minimization with no constraints. The method used for the one-dimensional search can be found in reference 2, listed at the end of this chapter. Procedure: 1. Given a starting point evaluate the derivatives of the objective function with respect to the primary variables. 2. Evaluate the new search direction as the conjugate to the old gradient. 3. Perform one-dimensional search along the new direction until the local minimum has been reached. 4. If any variable exceeds its bound, bring it back to the bound. 5. Repeat steps #1 through #4 until convergence. Quasi-Newton Method The Quasi-Newton method of Broyden-Fletcher-Goldfarb- Shanno (BFGS) according to Press et al2 has been implemented. In terms of applicability and limitations, this method is similar to the of Fletcher-Reeves method. The Fletcher Reeves (Conjugate Gradient) Method does not handle constraints. The Quasi-Newton Method does not handle constraints.7-16 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-17 ww ThThe Quasi-Newton method calculates the new search directions from approximations of the inverse of the Hessian Matrix. 7.2.6 Optimizer Tips The following are setup tips for the Original Optimizer. 1. Reasonable upper and lower variable bounds are extremely important. This is necessary not only to prevent bad flowsheet conditions (for example temperature crossovers in Heat Exchangers), but also because variables are scaled between zero and one in the optimization algorithms using these bounds. 2. For the BOX and Mixed methods, the Maximum Change/ Iteration of the primary variables (set on the Parameters tab) should be reduced. A value of 0.05 or 0.1 is more appropriate. 3. The Mixed method generally requires the least number of function evaluations (in other words, is the most efficient). 4. If the BOX, Mixed or SQP Methods are not honouring your constraints, try increasing the Penalty Value on the Functions tab by 3 or 6 orders of magnitude (up to a value similar to the expected value of the objective function). In other words, it is helpful to attempt to get the magnitude of the objective function and penalty as similar as possible (especially when the BOX Method is used). 5. By default the Optimizer minimizes the objective function. You can maximize the objective function by selecting the Maximize radio button on the Functions tab. Method Unconstrained Problems Constrained Problems: Inequality Constrained Problems: Equality Calculates Derivatives BOX X X Mixed X X X SQP X X X X Fletcher-Reeves X X Quasi-Newton X X Internally, the Optimizer multiplies the objective function by minus one for maximization.7-17 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-18 Hyprotech SQP Optimizer ww Th7.3 Hyprotech SQP Optimizer The Hyprotech SQP is a rigorous sequential quadratic programming (SQP) optimization solver. This solver features step size restriction, decision variable and objective function scaling, and a problem-independent and scale-independent relative convergence test. The algorithm also ensures that the model is evaluated only at points feasible with respect to the variable bounds. To access the Hyprotech SQP Optimizer: 1. On the Configuration tab, select the Hyprotech SQP radio button in the Data Model group, as shown in the figure below: 2. The Hyprotech SQP Optimizer property view contains two tabs: • Configuration • Hyprotech SQP The Hyprotech SQP requires the use of Derivative Utilities. Figure 7.7 Refer to the Aspen RTO Reference Guide for details. Refer to Section 7.1.2 - Configuration Tab for more information.7-18 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-19 ww Th7.3.1 Hyprotech SQP Tab The Hyprotech SQP tab allows you to manipulate the configuration Setup and Flags. Setup Options To access the Setup options, select Setup from the Configuration group on the Hyprotech SQP tab. The tab appears as shown in the following figure. The Derivative Utilities group lists the derivative utilities that are run in the optimizer. To add or remove utilities from this list, click Select Utilities to Run and select the desired utilities. The Starting Objective display field at the bottom right of the tab gives the objective function value at the starting point, before carrying out any optimization. The value is unscaled and you cannot change the value. The parameters available in the Setup option are sorted into two groups: • Setup • Running Results Figure 7.87-19 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-20 Hyprotech SQP Optimizer ww ThSetup Group The Setup Group contains the following parameters: Variables Description Max. Iterations Specifies the maximum number of major iterations. A major iteration consists of a sequence of minor iterations that minimize a linearly constrained sub-problem. The default value is 50. Objective Scale Factor Specifies the factor used for scaling the objective function. Positive values are used as-is. Negative values use the factor abs(scale*F) (where F is the initial objective function value) and a factor is generated automatically for zero values. The default value is 1.0. Gradient Calculations Specifies what type of differences are being used when constructing gradient approximations. 1-sided causes forward differences to be used. 2-sided causes central differences to be used; it requires twice as many function evaluations at a given solution, but can provide a more accurate estimate of the constraint and objective gradients, particularly for highly non-linear problems or problems featuring large amounts of noise. Diagnostic Print Level Specifies the amount of information to include in the Optimizer diagnostic file. Options are None, Partial_1, Partial_2, Partial_3, Full, or Excessive. This file is created in the working Temp directory: C:\Documents and Settings\Username\Local Settings\Temp Accuracy Tolerance Specifies the relative accuracy tolerance used in the test for convergence. The following convergence test is used, where: The ConvergenceSum is a weighted sum of possible objective function improvement and constraint violations and has the same units as the objective function. This allows the same tolerance parameter to be used for different problems and makes the convergence test independent of objective function scaling. The default value is 10-4. Step Restriction Specifies the line search step-size restriction factor used during the first 3 iterations. Values greater than 1.0 result in no step restriction. Set the factor to 1.0, 10-1, 10-2, and so forth, to impose larger restrictions. The default value is 0.2. ConvergenceSum AccuracyTolerance max× F x( ) 1.0,( )≤ ConvergenceSum ∇F x( )rd ujCj x( ) j 1= M ∑+=7-20 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-21 ww ThRunning Results Group You cannot change the values of the parameters in the Running Results group. The group contains the following parameters: Perturbation Specifies the change in size of the scaled variables used in Gradient and Jacobian calculations. Individual variables are scaled according to the variable Minimum and Maximum properties The default value is 10-3. Max. Feasible Point Specifies the maximum number of iterations allowed in the line search procedure of Hyprotech SQP. When the maximum feasible point iterations are reached, the solver terminates and displays an error message of Step Convergence, meaning that the required optimization accuracy cannot be achieved. If this error occurs very early in the calculation, the initial values of the optimization variables might be inappropriate. Variables Description Objective Value Displays the current plant model objective function value as calculated by the Optimizer. Termination Reason Displays the termination status of the Optimizer. Values include Running, Step convergence, Unbounded, Impossible, Not run, and Stopped. Actual Optimizer Displays the number of major iterations. Feasible Point Iterations Displays the number of minor iterations since the last major iteration. Total CPU Time Reports the time taken to solve the optimization problem. Solution Phase Displays the current phase of the Optimizer algorithm. Values include Initialize, Setup, OPT Deriv, OPT Search, and Results. Gradient Evaluations Reports the number of gradient evaluations performed during the course of the optimization. Model Evaluations Reports the number of model evaluations performed during the course of the optimization. Code Version The version of Optimizer. Variables Description7-21 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-22 Hyprotech SQP Optimizer ww ThResults The results produced at the end of the optimization run are as follows: • Values of the Optimizer constraints, variables, and objective function. • Shadow prices for active constraints. • A termination reason. • Iterations and CPU time taken. Some of the above mentioned results can be seen in the Running Results group, and the other results are found in the Derivative utilities. Flags Option If you select the Flags radio button from the Configuration group, the Hyprotech SQP tab appears as shown in the figure below. Figure 7.97-22 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-23 ww ThThe following table explains the options available in Flags group: 7.4 MDC Optim This option gives you access to MDC Optim optimization solver. This option is only available with a HYSYS.RTO license. For more information on this solver, refer to the Optimizer section in the Aspen HYSYS.RTO Reference Guide. Options Description Omit. Tech Constraints Not used. Relax Violated Constraints Not used. Include Fixed Constraints If this checkbox is selected, then the Optimizer variables that have their Optimize Flag property checkbox selected are included in the optimization even if they have equal Minimum and Maximum values. Numerical Gradients Not used. Hyprotech SQP Calc Gradients If this flag is checked when the Hyprotech SQP solver is used, then the Hyprotech SQP algorithm itself carries out numerical calculation of any gradient elements needed. Include Variable Scales Includes the variable Range properties as scaling factors within the algorithm. Reset Perts. Used at the start of optimization to indicate that the gradient calculation process removes noise elements (activated) or not (deactivated). Use NN for Optimization Allows you to use any trained Neural Network in the flowsheet to replace the traditional HYSYS solver for optimization. This improves the robustness of the model, and reduces the calculation time thereby improving overall performance. However, the accuracy in the solution depends upon how the NN is trained and the data available. Upon solving the NN’s are unembedded and the flowsheet solves at the optimizer given values. Use NN for Jacobian Allows you to use any trained Neural Network to calculate the Jacobian. This is used to determine the next step in the Optimization process. This is slower than the above option but is more accurate. See Optimization above for more details. Refer to Section 14.14 - Parametric Utility for more details on NN’s.7-23 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-24 DataRecon ww Th7.5 DataRecon The DataRecon object access the Data Reconciliation Utility. For more information on this utility, refer to the Data Reconciliation Utility section of the Utilities chapter of this manual. 7.6 Selection Optimization The Selection Optimization consists of algorithms that solve Mixed Integer Non-Linear Programming (MINLP) problems, in which the objective function is minimized by adjusting both the real-valued decision variables, and binary-valued decision variables. These binary, or discrete state variables can be used to represent the state of the equipment (On, Off, Out of Service, and Always in Service) in the Derivative Utility. The algorithms attempts to select a combination of discrete states that both satisfy the constraints, and minimize the objective function. There are two MINLP methods available: Stochastic (also known as the simulated annealing method), and Branch and Bound. These methods use Non-Linear Programming (NLP) optimizers (Hyprotech SQP, and MDC Optim) to solve sub-problems. To access the Selection Optimization: 1. On the Configuration tab, select the Selection Optimization radio button in the Data Model group. 2. Click on the Selection Optimization tab. 7.6.1 Selection Optimization Tab The Selection Optimization tab allows you to select, and configure the type of discrete solver, and non-linear optimizer. Two base groups are available on the Selection Optimization tab:7-24 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-25 ww Th• Discrete Solver Options. You can select the Stochastic, or Branch and Bound solver by clicking on the appropriate radio button. Depending on the type of discrete solver you selected, additional groups appear on the Selection Optimization tab. • Non Linear Optimization Configuration. There are two non- linear optimizers available: Hyprotech SQP, and MDC Optim. You can select the type of non-linear optimizer by clicking on the appropriate radio button. Depending on the type of non-linear optimizer you selected, additional tabs appear on the Optimizer property view for further configuration. The following sections describe the Stochastic, and Branch and Bound discrete solving methods. Stochastic Method The Stochastic method is a simulated annealing algorithm, which is derived from the statistical mechanics for finding near globally optimum solutions in non-linear integer problems. The algorithm is based on the analogy between the annealing of solids, and combinatorial optimization. The analogies are as follows: • The states of the solids in annealing represent the feasible solutions of the optimization problem. • The energies of state in annealing correspond to the value of the objective function. • The minimum energy state in annealing corresponds to the optimum solution. • Rapid quenching (fast cooling) corresponds to local optimum in the optimization problem. At a given temperature, the probability distribution of the system energies is determined by the Boltzmann function: where: E = System energy (7.5) For more information, refer to Hyprotech SQP Optimizer (Section 7.3 - Hyprotech SQP Optimizer), and MDC Optimizer (Chapter 5 - DRU Overview in the Aspen RTO Reference Guide). P E( ) e E kT( )⁄–∝7-25 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-26 Selection Optimization ww Thk = Boltzmann constant T = Temperature P(E) = Probability of the system in a state with E energy The simulated annealing algorithm implemented in the Stochastic method uses a criterion similar to the Boltzmann probability function. The criterion states that if the difference between the objective function values of the current and the newly produced solution is equal to or larger than zero, a random number, ,with uniform distribution [0,1] is generated. If the random number satisfy the following condition: then the newly produced solution is accepted as the current solution; else the current solution is unchanged. Once a state (set of discrete variables) is selected based on the above criterion, the solution to the problem is obtained by using non-linear optimization. The Stochastic method consists of two groups: • Stochastic Parameters • Stochastic Optimization Output Stochastic Parameters Group The Stochastic Parameters consists of three parameters: (7.6) Figure 7.10 ∂ ∂ e EΔ T⁄–≤7-26 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-27 ww ThStochastic Optimization Output Group In the Stochastic Optimization Output group, you can view the Best Objective Function value in the optimization based on the parameters specified in the Stochastic Parameters group. Branch and Bound Method The Branch and Bound method first solves the original MINLP problem as a NLP problem by relaxing the integer restrictions, so that the calculations can converge with a less tight integer tolerance. The method continues by performing a systematic search of continuous solutions (called nodes), in which the integer variables are successively forced to take on integer values. This process is known as branching. The structure of this set of problems takes on the form of a tree. The procedure of branching, and solving a sequence of continuous problems is continued until a feasible integer solution is found. The value of the objective function becomes an upper bound of the objective Parameter Description No Of Iterations Allows you to specify the number of iteration in the simulated annealing algorithm. The number of iteration is a hard limit which means that the algorithm stops when the specified number of iteration is reached. By default, the No Of Iterations is set to 10. Time Limit Allows you to specify the algorithm time constraint (in minute). Once the Time Limit value is reached, the algorithm completes the move that it is solving. By default, the Time Limit is set at 2. Annealing Temperature Allows you to specify the temperature that is used to control the progression of the optimization problem toward an optimum solution. As a general rule, the Annealing Temperature should be the same order of magnitude of the Best Objective Function. By default, the Annealing Temperature is set to 1.000e- 003. Figure 7.117-27 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-28 Selection Optimization ww Thof the MINLP problem. At this point, all of the continuous solutions whose objective function values are higher than the upper bound are eliminated from consideration. This elimination process is known as fathomed. Nodes are fathomed when the continuous problem is infeasible or when it has a natural integer solution. The search for the optimal solution terminates when all nodes are fathomed. The Branch and Bound method contains two main groups: • Branch and Bound Parameters • Branch and Bound Output Branch and Bound Parameters The Branch and Bound Parameters group consists of five sub groups: • Branching • Node Selection • Convergence • Bluff • Search Figure 7.127-28 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-29 ww ThBranching The Branching group contains the following parameters: Node Selection A node is explicitly or implicitly fathomed when it satisfies one of the following conditions: • when the solution is an integer value • when the solution is infeasible • when the optimal value is higher than the current upper bound Figure 7.13 Parameters Description Order Allows you to specify the method for selecting the branching variable. You can select the type of Order from the Order drop-down list: • Fractional. Selects the most fractional binary variable. • Fixed. Selects the variable by using the binary variable parameter rank. By default, the Order is set to Fractional. Search Allows you to indicate whether a branch-and-bound search is to be performed after the solution of the relaxed problem is found. By default, the Search is set to Yes. Figure 7.147-29 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-30 Selection Optimization ww ThThe Node Selection group contains the following parameters: Convergence The Convergence group allows you to specify the integer restrictions and convergence conditions. The Convergence group contains the following parameters: Parameters Description Select Allows you to specify the method of node selection: • Best Bound. Selects the node with the lowest objective function value. • Dive. Selects the most recent node for branching. By default, Best Bound method is selected. Maximum Allows you to specify the maximum number of nodes to be searched (excluding relaxing and heuristic problems). The Maximum must be equal or larger than 1, and by default, it is set to 10. Figure 7.15 Parameters Description Absolute Allows you to specify the absolute convergence tolerance. The tolerance is compared with the absolute difference between the upper and lower bounds on the objective function. By default, the Absolute is set to 0.0. Relative Allows you to specify the relative convergence tolerance. The tolerance is compared with the relative difference between the upper and lower bounds on the objective function. The Relative value must be within the range of 0.0 to 1.0. By default, the Relative is set to 0.1. Integer Tolerance Allows you to specify the tolerance used when testing whether a relaxed binary variable is considered to be binary-valued (in other words, 0 or 1). The Integer Tolerance must be in between 0.0 to 0.5. By default, the Integer Tolerance is set to 1.0e-4.7-30 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-31 ww ThSearch The Search group contains the following parameters: Initialization Allows you to specify the method of initializing optimization variables prior to the solution of each sub-problem. You can select one of following options from the Initialization drop- down list: • Current. Does not perform any re-initialization. In other words, variable values start with the values they had at the end of the previous sub-problem. • Initial. Sets variables to the values that they had when the algorithm was started. • Relaxed. Sets the variables to the optimal values found for the relaxed sub-problems. By default, the Initialization option is set to Current. Time limit (min) Allows you to specify a time limit (in minutes) for the search procedure. The Time limit is used in addition to the maximum number of nodes to place a limit on the length of the search. The Time limit value must be greater than 0.0. By default, the Time limit field is . Figure 7.16 Parameters Description7-31 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-32 Selection Optimization ww ThBluff There are three parameters in the Bluff group: • Gap. Provides an estimate of the relative gap between the objective function values of the relaxed problem, and optimal integer solution. The algorithm computes an upper bound on the objective function value after the solution of the relaxed problem. This is used to eliminate nodes in the search tree whose objective functions are not better than the Incumbent. The Incumbent objective function FI is calculated from the fully relaxed objective FR, and the Gap is defined as: Parameters Description Quit Allows you to end (Yes) or continue (No) the search when an improved integer solution over the Incumbent is found. By default, the Quit option is set to No. Quit Tolerance The Quit Tolerance provides the relative amount of improvement required in an integer solution to end the search. This parameter only has an effect if the Quit option is selected as Yes. The relative improvement in the Incumbent is defined as: where: FI = Objective function of the incumbent fI = Objective function of the improved integer solution If the Quit Tolerance field is specified as 0.0 or left empty, finding any improvement will end the search. By default, the Quit Tolerance is . You can only specify the Quit Tolerance value equal to or greater than 0.0. Figure 7.17 (7.7) FI fI–( ) FI ------------------- FI FR Gap 1.0 FR+( )⋅+=7-32 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-33 ww ThThe branch-and-bound search will fail if the Gap value is too small. By default, the Gap field is . The Gap value must be greater than 0, and it is recommended to set it to 0.25. • Incumbent. The objective function value of the best binary-valued solution known so far. The value is used to eliminate nodes in the search that are not better than the Incumbent value. A value given for the Incumbent will override the value generated by using the Gap value. By default, the Incumbent field is . • Heuristic. Allows you to specify the type of heuristic algorithm for finding an initial integer-feasible solution that is used to update the objective function Incumbent value. There are two types of Heuristic: - Initial. Uses initial State Variable values. - Round. Round the values of the State Variables. Branch and Bound Output The Branch and Bound Output group contains the following fields for displaying the optimization results: By default, the Heuristic type is set to None. It is recommended that the type to be set to Initial. Figure 7.18 Parameters Description Relaxed Obj. Value of the objective function for the fully relaxed problem. Incumbent Obj. Value of the Incumbent objective function. The Incumbent is the lowest objective function of an integer-valued solution. This value is initialized by using the user-specified Incumbent and Gap parameters. The Incumbent Obj value is updated throughout the branch and bound search. Current Node The node of the branch and bound tree currently being solved. A number of 0 indicates that it is a fully relaxed problem.7-33 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-34 Selection Optimization ww Th7.6.2 Selection Optimization Tips The following are setup tips for the Selection Optimization: 1. Since the algorithm used in the Stochastic method moves all over the solution space, the higher the number of iterations that the algorithm performs, the higher the probability there will be for finding a global optimum solution. 2. In the Branch and Bound method, reasonable convergence criteria, for example, value of Relative is important. It is recommended that you should accept the solution if an integer-feasible solution can be found during the search that has an objective function close to that of the fully relaxed solution. 3. In the Branch and Bound method, use Gap or Incumbent to reduce the size of the search space. Be aware that too much bluffing (for example a small value of Gap) can eliminate large sections of the search tree, resulting in a failed or sub- optimal search. 4. It is important to specify a Heuristic type in Branch and Bound method, especially if the Gap or Incumbent have not been specified. If the Heuristic successfully finds an integer- feasible solution, the objective function value can be used to eliminate sections of the search region. The Heuristic can satisfy the convergence criteria.7-34 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-35 ww Th7.7 Example: Original Optimizer Create the following sample case of multiple heat exchangers to optimize the overall UA by using the Original Optimizer. PFD Using the Peng Robinson property package and the listed components specify the process streams outlined in the following table. Inlet Process Streams Figure 7.19 Material Streams Tab [Page] In this cell... Feed E-100 Cool In Valve In E-102 Cool In Worksheet [Conditions] Temperature (F) 20 -142 120 Pressure (psia) 1000 250 350 251 Molar Flow (lbmole/hr) 2745 1542 16407-35 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-36 Example: Original Optimizer ww ThProcess Operations A tee, mixer, valve, and three heat exchangers are required for this process. Enter the data as shown in the figures below. • TEE-100 Worksheet [Composition] Methane Mole Frac 0.7515 0.9073 0.0000 0.2828 Ethane Mole Frac 0.2004 0.0927 0.0000 0.2930 Propane Mole Frac 0.0401 0.0000 1.0000 0.1414 i-Butane Mole Frac 0.0040 0.0000 0.0000 0.1313 n-Butane Mole Frac 0.0040 0.0000 0.0000 0.1515 Material Streams Tab [Page] In this cell... Feed E-100 Cool In Valve In E-102 Cool In Figure 7.207-36 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-37 ww Th• MIX-100 • VLV-100 Figure 7.21 Figure 7.227-37 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-38 Example: Original Optimizer ww Th• Heat Exchanger E-100 • Heat Exchanger E-101 Figure 7.23 Heat Exchanger [E-100] Tab [Page] In this cell... Enter Design [Parameters] Tubeside Delta P 10 psi Shellside Delta P 10 psi UA 4.00e+04 Btu/F-hr Heat Leak/Loss None Heat Exchange Model Weighted Intervals (E-100 Feed) 10 Intervals (E-100 Cool In) 10 Dew/Bubble Pt (E-100 Cool In) Inactive Figure 7.247-38 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-39 ww Th• Heat Exchanger E-102 Heat Exchanger [E-101] Tab [Page] In this cell... Enter Design [Parameters] Tubeside Delta P 5 psi Shellside Delta P 1 psi UA 5.00e+04 Btu/F-hr Heat Leak/Loss None Heat Exchange Model Weighted Intervals (E-100 Feed) 10 Intervals (E-100 Cool In) 10 Figure 7.25 Heat Exchanger [E-102] Tab [Page] In this cell... Enter Design [Parameters] Tubeside Delta P 5 psi Shellside Delta P 5 psi UA 3.50e+04 Btu/F-hr Heat Leak/Loss None Heat Exchange Model Weighted Intervals (E-100 Feed) 10 Intervals (E-100 Cool In) 10 Dew/Bubble Pt (E-102 Cool In) Inactive7-39 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-40 Example: Original Optimizer ww ThStream Specifications • Temperature of stream E-102 Out, -40°F • Vapour Fraction stream E-101 Cool Out, 1.00 • Temperature of stream E-100 Out, -65°F • Pressure of E-101 Cool Out, 20 psia Results The calculated streams are shown in the figure below. 7.7.1 Optimizing Overall UA The Optimizer determines the optimum Tee flow ratio such that the Overall UA is minimized. Therefore, delete the individual heat exchanger UA specs and replace them with the following: • Temperature of E-102 Cool In = -85°F • Flowrate of Valve In = 495 lbmole/hr • Flowrate of E-101 Feed = Optimized variable (Initially set to the previous flow rate of 1,670 lbmole/hr) After replacing the specs, the flowsheet solves and UAs are calculated. Figure 7.267-40 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-41 ww ThOpening the Optimizer To open the Optimizer: 1. Click the Add button in the Variables tab to display the Variable Navigator. 2. Select the Molar Flow of the stream E-101 Feed. 3. Specify the Low and High Bounds as shown in the figure below. The search is now within a range of 1450 lbmole/hr - 1800 lbmole/hr to avoid a temperature cross. Import the Heat Exchanger To import the three Heat Exchanger UAs to the Optimizer spreadsheet: 1. Click the SpreadSheet button to display the Optimizer Spreadsheet property view. 2. Click the Connections tab and then click the Add Import button to display the Variable Navigator property view. 3. Import the UA value for the heat exchanger E-100. Figure 7.277-41 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-42 Example: Original Optimizer ww Th4. Repeat steps#2 and#3 for the Heat Exchangers E-101 and E-102. 5. Click the Spreadsheet tab. In cell A4, enter the formula, +a1+a2+a3. This sums the UAs. In cell A5, enter 0.0. This is used in the constraints. 6. Close the Optimizer Spreadsheet property view. Defining the Objective Function You must define the Objective Function and the Constraint Functions. The Objective Function is the expression being minimized, which in this case is the sum of the Heat Exchanger UAs. 1. Click the Functions tab in the Optimizer property view. 2. Click the Cell drop-down list and select A4. The value of the cell is displayed in the Current Value field. 3. Click the Minimize radio button. Figure 7.287-42 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-43 ww ThAdding Constraint Functions Enter constraint functions to ensure the solution is reasonable. Each Heat Exchanger UA must be greater than zero. 1. Click the Add button three times to add three constraints to the table. 2. In the LHS Cell drop-down list, select the cell A1, A2, and A3 for each of the respective constraints. 3. In the RHS Cell drop-down list, select the cell A5 for each of the constraints. 4. Click the Parameters tab. For this example, use the Mixed method leaving all the parameters at their defaults. 5. Click the Start button, and then click the Monitor tab to watch the progress of the Optimizer. An optimum molar flow of 1,800 lbmole/hr is obtained for the stream E-101 Feed, corresponding to an overall UA of about 1.43e5 Btu/F-hr. This compares to the specified value of 1.5e5 Btu/F-hr in the first part of this example. Figure 7.297-43 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-44 Example: MNLP Optimization ww Th7.8 Example: MNLP Optimization In this example, the Hyprotech SQP Optimizer is used with Selection Optimization to determine the most economical use of each boiler in a steam utility system to meet the steam demand. Create the following steam utility system in Steady-State. PFD The steam demand is supplied by using three parallel boilers connected to a common high-pressure header. The boilers are modeled as simple heaters, each with different capacity, fuel cost, overhead cost, and efficiency. The high-pressure header is modeled by using a tee unit operation. Figure 7.307-44 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-45 ww ThDefining the Simulation Basis 1. In the Simulation Basis Manager, define the property package as NBS Steam, and specify water (H2O) as the component. 2. Specify the Feed stream as follows: 3. Specify the mass flowrate for the following boiler inlet streams: The mass flowrate of B1 IN is 5,400 kg/h, which is automatically calculated by HYSYS after you have defined B2 IN and B3 IN. 4. Specify a temperature of 350°C (662°F) for all three boilers outlet streams (B1 OUT, B2 OUT, and B3 OUT). 5. Specify a pressure drop of 0 kPa for each boiler. The steam utility system is now fully defined. The results of each stream are summarized in the Workbook as shown below: In this cell... Enter... Temperature 21.3°C (70.3°F) Pressure 4,101.3 kPa (594.8 psia) Mass Flow 14,400 kg/h (31746 lb/hr) Mass Fraction (H2O) 1 Stream Mass Flowrate B2 IN 3,600 kg/h (7937 lb/hr) B3 IN 5,400 kg/h (11905 lb/hr) Figure 7.31 Refer to Section 5.2 - Simulation Basis Manager in the HYSYS User Guide for more information on selecting a property package, and adding components.7-45 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-46 Example: MNLP Optimization ww ThHeat Flow & Costs Calculations Before the case is converted into an optimization problem, the efficiency, actual heat flow, and operating cost for each boiler are calculated within the Spreadsheet operation. Add a Spreadsheet operation to the case and name it to Boilers Calculations. Efficiency The efficiency of the three boilers are locally characterized by the following relationship: where: Eff = Efficiency of the boiler EffMAX = Maximum efficiency of the boiler Flow = Inlet mass flowrate of the boiler FlowMAX = Inlet mass flowrate of the boiler at maximum efficiency FlowMAX-5% = Inlet mass flowrate at an efficiency 5% less than the maximum efficiency. The squared term in Equation (7.8) is a scaled deviation in flowrate with respect to the mass flow which gives the maximum efficiency. (7.8) The quadratic approximation between the steam mass flowrate, and boiler efficiency is valid only within a narrow range of operation, localized near the point of maximum efficiency. Refer to Section 5.10 - Spreadsheet for more information on the Spreadsheet operation. Eff EffMAX 5% Flow FlowMAX– FlowMAX 5%– FlowMAX– -------------------------------------------------------------⎝ ⎠ ⎛ ⎞ 2 ×–=7-46 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-47 ww ThThe following table lists the efficiency parameters associated with each boiler: Calculate the efficiency of each boiler in the Boilers Calculations spreadsheet. The following efficiency results should appear on the Spreadsheet: Actual Heat Flow The heat flow values calculated in HYSYS are the heat flow required by each boiler when the boiler is operating at the efficiency calculated from Equation (7.8). Therefore, the actual heat flow is calculated with the following equation: where: Heat Flow = Heat flow of the boiler calculated in HYSYS Eff = Efficiency of the boiler (see Equation (7.8)) Parameters B1 B2 B3 EffMAX 85% 87% 90% FlowMAX 1.8 kg/s 2.2 kg/2 1.6 kg/s FlowMAX-5% 3.0 kg/s 3.8 kg/s 2.5 kg/s Figure 7.32 (7.9)Actual Heat Flow Heat Flow 100 Eff --------×=7-47 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-48 Example: MNLP Optimization ww ThThe calculated efficiencies are used to calculate the Actual Heat Flow required by each boiler. The following results should appear on the Boilers Calculations spreadsheet: Cost Calculations The objective of this optimization problem is to minimize the total operating cost of the system, which is defined as the additive operating costs of each boiler: where: i = Boiler i The operating cost for each boiler is the sum of the fuel consumption cost, and overhead cost associated with the operation. The fuel cost, and the overhead cost of each boiler are listed in the following table: Figure 7.33 (7.10) Cost B1 B2 B3 Fuel ($/MJ) 0.008 0.0085 0.0088 Overhead ($/hr) 30 29 25 Total Operating Cost (Operating Cost)∑ i = 7-48 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-49 ww ThSince the overhead cost only applies when the boiler is operating, the overhead cost is multiplied to a binary state variable of 1 or 0; a value of 1 indicates an ‘on’ status, and 0 reflects a ‘off’ status. The operating cost for each boiler is defined as follows: where: Status = Binary state variable of the boiler (1 = on, 0 = off) To specify an ‘on’ status for all three boilers in the Boilers Calculations spreadsheet: 1. Create a new column called Status. 2. Specify a value of 1 in three spreadsheet cells under the Status column to represent the state of the three boilers. For now, it is assumed that all three boilers are in operation. Therefore the overhead cost applies to all three boilers. During optimization, the Status of each boiler changes accordingly to obtain the minimum objective function. The following operating cost for each boiler should appear on the Boilers Calculations spreadsheet: (7.11) Figure 7.34 Operating Cost Actual Heat Flow⎝ ⎠ ⎛ ⎞ Fuel Cost⎝ ⎠ ⎛ ⎞ Overhead Cost⎝ ⎠ ⎛ ⎞+× Status×=7-49 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-50 Example: MNLP Optimization ww Th7.8.1 NLP Setup Defining the Optimizer 1. Select Optimizer from the Simulation menu. The Optimizer property view appears. 2. In the Optimizer property view, select the Hyprotech SQP radio button on the Configuration tab. 3. Click on the Hyprotech SQP tab. 4. In the Configuration group, click on the Setup radio button. 5. In the Setup group, set the Accuracy Tolerance to 1.00e- 006, and set the Perturbation to 1.00e-004. 6. Close the Optimizer property view. Adding the Derivative Utility 1. Select Utilities from the Tools menu. 2. Select Derivative Utilities. 3. Click the Add Utility button to add a Derivative Utility. The Derivative Utility property view appears. Figure 7.35 Refer to Section 7.3 - Hyprotech SQP Optimizer for more information on Accuracy Tolerance and Perturbation. Refer to Section 7.26 - Utilities in the HYSYS User Guide for more information on Utilities.7-50 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-51 ww ThDefining the Object Filter 1. Click on the Configuration tab in the Derivative Utility property view. 2. In the Derivative Utility Configuration group, click on the Operation button. The Target Objects property view appears. Figure 7.36 Figure 7.377-51 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-52 Example: MNLP Optimization ww Th3. Click on the Flowsheet Wide radio button in the Object Filter Group. 4. Select FlowsheetWide in the Flowsheet Wide group. 5. Click the Transfer icon to transfer FlowsheetWide to the Scope Objects group. 6. Click the Accept List button in the Scope Objects group to save the setting. The Target Objects property view closes. Defining the Optimization Variables 1. In the Derivative Utility property view, click on the Variables tab. 2. In the Variables tree browser, select the Variables branch. 3. Click on the Plus icon to expand the Variables branch. 4. Select the Config. sub branch. 5. In the Derivative Utility Configuration group, select OptVars from the Add drop-down list. 6. Click on the Add button. The Select optimization variables and DCS Tags property view appears. 7. Select B2 IN from the Object list. 8. Select Mass Flow from the Variable list. 9. Click OK. The mass flowrate of B2 IN is added to the Variables Config table on the Variables tab in the Derivative Utility property view. Figure 7.38 Transfer icon Variables tree browser7-52 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-53 ww Th10.Rename the Object Name to B2 IN as shown below: 11.Click on the Input sub branch under the Variables branch in the Variables group. 12. In the Variables Input table, set the Minimum, and Maximum of B2 IN to 0, and 36,000 kg/h, respectively. 13.Repeat step 2 to 12 for B3 IN. Defining the Objective Function 1. In the Derivative Utility property view, click on the Constraints/Objective Functions tab. 2. In the Dependent tree browser, select the Objective Function branch. 3. In the Derivative Utility Configuration group, select ObjFunc from the Add drop-down list. 4. Click the Add button. The Select optimization variables and DCS Tags property view appears. 5. Select Boilers Calculations as the Object. 6. From the Variable list, select the cell where you calculated the total operating costs of all three boilers. 7. Click OK. The Total Operating Cost value appears in the Objective Function table on the Constraints/Objective Function tab. 8. Set the Price to 1. 9. Change the Object Name to Total Cost as shown below. Figure 7.39 Figure 7.40 Dependent tree browser7-53 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-54 Example: MNLP Optimization ww ThDefining the Process Constraints 1. In the Derivative Utility property view, click on the Constraints/Objective Function tab. 2. Expand the Process Constraints branch from the Dependent tree browser. 3. Select the Config. sub branch. 4. In the Derivative Utility Configuration group, select ProcCons from the Add drop-down list. 5. Click the Add button. 6. Select the Boilers Calculations spreadsheet from the Variable list. 7. From the Object List, select the cell where you calculated the actual heat flow for boiler 1. 8. Click OK. 9. In the Process Constraint Config table, change the Object Name of the newly added process constraint to Q1 as shown below: 10. In the Dependent group, select the Input sub branch under the Process Constraints branch. 11.Set the Scale to 1. 12.Specify a Minimum of 0 and Maximum of 12,500 kW as show below: 13.Select the Use Flag checkbox. The Use Flag checkbox allows you to eliminate evaluation of infeasible integer candidate. You can reduce the amount of time for the optimization calculation by selecting the appropriate variables. Figure 7.41 Figure 7.42 Dependent tree browser7-54 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-55 ww Th14.Add a series of process constraints as shown in the table below by repeating step 2 to 13 for each constraint. 7.8.2 MINLP Setup Defining Slack Variables Three slack variables are added to the Boilers Calculations spreadsheet to represent the maximum flow constraints on the inlet mass flowrate of each boiler. The slack variable is defined as follows: where: SlackMAX = Maximum slack value Flow = Inlet mass flowrate of the boiler FlowMAX = Maximum inlet mass flowrate of the boiler (36,000 kg/h) 1. Calculate the slack values for the three boilers. The following slack values should appear in the Boilers Calculations spreadsheet: Variable Object Object Name Minimum Maximum B2 Heat Flow Q2 0 kW 9,500 kW B3 Heat Flow Q3 0 kW 13,500 kW B1 IN Mass Flow B1 IN 0 kg/s 10 kg/s B2 IN Mass Flow B2 IN 0 kg/s 10 kg/s B3 IN Mass Flow B3 IN 0 kg/s 10 kg/s (7.12) Figure 7.43 SlackMAX Flow= FlowMAX– Status×7-55 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-56 Example: MNLP Optimization ww Th2. Add the slack values from the Boilers Calculations spreadsheet to the Derivative Utility as process constraints. 3. In the Derivative Utility, set the Maximum of each slack variable to 0. 4. Set the Minimum to a superfluous value of -1.00e+006. 5. Rename the slack values as Slack Max B1, Slack Max B2, and Slack Max B3 for the appropriate boiler 6. Select the Use Flag checkbox for all slack variables. The Process Constraints table should contain all the constraints as shown in the following figure: Defining the State Variables Define three state variables in the Derivative Utility to reference the three binary equipment states from the Boilers Calculations spreadsheet. To add the state variables in the Derivative Utility: 1. In the Derivative Utility property view, click on the Variables tab. 2. In the Variables group, select the State Variable branch. 3. Select StateVars from the Add drop-down list in the Derivative Utility Configuration group. 4. Click Add. 5. Select Boilers Calculations as the Object. 6. From the Object List, select the cell where you specified the binary state variable for Boiler 1. 7. Click OK. 8. Rename the newly added state variable to Use B1. Figure 7.44 Refer to the section on Defining the Process Constraints for more information on adding process constraints in the Derivative Utility.7-56 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-57 ww Th9. Repeat step 3 to 8 for Boiler 2, and Boiler 3. The State Variables table should appear as follows: 10.Click the Close button to close the Derivative Utility property view. Defining the Selection Optimization The final step is to define the Selection Optimization requirements. 1. Select Optimizer from the Simulation menu. 2. Click on the Selection Optimization radio button. 3. Click on the Selection Optimization tab. 4. Click on the Stochastic radio button in the Discrete Solver Options group. 5. In the Stochastic Parameters group, set the Time Limit (min) to 5. 6. Set the Annealing Temperature to 100. 7. Click the Start button. Optimization Results The lowest cost (best objective function value) is displayed in the Stochastic Optimization Output Group on the Selection Optimization tab of the Optimizer property view: Figure 7.45 Figure 7.467-57 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-58 Example: MNLP Optimization ww ThThe flow, and operating conditions of each boiler required to achieve the best objective function value are summarized in the Boilers Calculations spreadsheet as shown below: Figure 7.477-58 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Optimizer Operation 7-59 ww Th7.9 References 1 Box, M.J. “A New method of Constrained Optimization and a Comparison with other Methods,” Computer J., 8, 42-45, 1965. 2 Press, W.H., et al, “Numerical Recipes in C,” Cambridge university Press, 1988. 3 Kuester, J.L. and Mize, J.H., “Optimization Techniques with FORTRAN,” McGraw-Hill Book Co., 1973. 4 Harwell Subroutine Library, Release 10, Advanced Computing Dept., AEA Industrial Technology, Harwell laboratory, England, 1990. 5 Powell, M.J.D., “A Fast Algorithm for Non-Linearly Constrained Optimization Calculations,” Numerical Analysis, Dundee, 1977, Lecture Notes in Math. 630, Springer-Verlag, 1978. 6 Chamberlain R.M. and Powell, M.J.D., “The Watchdog Technique for Forcing Convergence in Algorithms for Constrained Optimization,” Mathematical Programming Study, 16, 1-17, 1982.7-59 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 7-60 References ww Th7-60 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-1 ww Th8 Reactor Operationsw.cadfamily.com EMa e document is for study 8.1 CSTR/General Reactors.................................................................. 3 8.1.1 Adding a CSTR/General Reactors ................................................ 4 8.2 CSTR/General Reactors Property View........................................... 5 8.2.1 Design Tab .............................................................................. 6 8.2.2 Conversion Reactor Reactions Tab............................................. 10 8.2.3 CSTR Reactions Tab ................................................................ 17 8.2.4 Equilibrium Reactor Reactions Tab ............................................ 22 8.2.5 Gibbs Reactor Reactions Tab .................................................... 28 8.2.6 Rating Tab............................................................................. 32 8.2.7 Worksheet Tab ....................................................................... 36 8.2.8 Dynamics Tab ........................................................................ 37 8.3 Yield Shift Reactor ....................................................................... 42 8.3.1 Yield Shift Reactor Property View.............................................. 45 8.3.2 Design Tab ............................................................................ 47 8.3.3 Model Config Tab.................................................................... 49 8.3.4 Composition Shift Tab ............................................................. 52 8.3.5 Property Shift Tab .................................................................. 65 8.3.6 Worksheet Tab ....................................................................... 73 8.3.7 Dynamics Tab ........................................................................ 73 8.4 Plug Flow Reactor ........................................................................ 74 8.4.1 Adding a Plug Flow Reactor (PFR) ............................................. 77 8.5 Plug Flow Reactor (PFR) Property View ....................................... 78 8.5.1 PFR Design Tab ...................................................................... 79 8.5.2 Reactions Tab ........................................................................ 87 8.5.3 Rating tab ............................................................................. 96 8.5.4 Work Sheet Tab...................................................................... 998-1 il:cadserv21@hotmail.com only,if tort to your rights,please inform us,we will delete 8-2 Reactor Operations www.cadfamily.com EMa The document is for study 8.5.5 Performance Tab .....................................................................99 8.5.6 Dynamics Tab.......................................................................1028-2 il:cadserv21@hotmail.com only,if tort to your rights,please inform us,we will delete Reactor Operations 8-3 ww Th8.1 CSTR/General Reactors With the exception of the Plug Flow Reactor (PFR), all of the reactor operations share the same basic property view. The primary differences are the functions of the reaction type (conversion, kinetic, equilibrium, heterogeneous catalytic or simple rate) associated with each reactor. As opposed to a separator or general reactor with an attached reaction set, specific reactor operations can only support one particular reaction type. For instance, a conversion reactor only functions properly with conversion reactions attached. If you try to attach an equilibrium or a kinetic reaction to a conversion reactor, an error message appears. The GIBBS reactor is unique in that it can function with or without a reaction set. You have a great deal of flexibility in defining and grouping reactions. You can: • Define the reactions inside the Basis Manager, group them into a set and then attach the set to your reactor. • Create reactions in the Reaction Package in the main flowsheet, group them into a set, and attach the set to the reactor. • Create reactions and reaction sets in the Basis Environment and make changes in the Main Environment's Reaction Package. Regardless of the approach, the reactions you define are visible to the entire flowsheet. In other words, a reaction set can be attached to more than one reactor. However, there are some subtleties of which you must be aware. When you make a modification to a reaction via a reactor, the change is only seen locally, in that particular reactor. Modifications made to a reaction in the Basis Environment or in the Reaction Package are automatically reflected in every reactor using the reaction set, provided you have not made changes locally. Local changes are always retained. Refer to Chapter 5 - Reactions of the HYSYS Simulation Basis guide or Section 5.3 - Reaction Package of the HYSYS User Guide for details on installing reactions and Reaction Sets.8-3 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-4 CSTR/General Reactors ww ThTo override local changes and return the global parameters to a reaction, you must press the DELETE key when the cursor is in the cell which contains the local change. To remove local changes, select the appropriate cell and press the DELETE key. The four reactors which share common property views include: • CSTR (Continuous-Stirred Tank Reactor) • GIBBS Reactor • Equilibrium Reactor • Conversion Reactor • Yield Shift Reactor The last four reactors are referred to as General Reactors. In order to avoid redundancy, CSTR, Gibbs, Equilibrium, and Conversion reactor operations are discussed co-currently. In areas of the property view where there are differences, such as the Reactions tab, the differences are clearly noted. The Yield Shift and PFR have a different property view from the other reactors. As a result it is discussed in Section 8.3 - Yield Shift Reactor and Section 8.4 - Plug Flow Reactor. 8.1.1 Adding a CSTR/General Reactors There are two ways that you can add a reactor operation to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Reactors radio button. 3. From the list of available unit operations, select the reactor type you want to add: Cont. Stirred Tank Reactor, Conversion Reactor, Equilibrium Reactor, Gibbs Reactor, or Yield Shift Reactor. 4. Click the Add button. 8-4 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-5 ww ThOR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Do one of the following: • For continuous-stirred tank reactor, double-click the CSTR icon. The CSTR property view appears. • For Conversion, Equilibrium, Gibbs, and Yield Shift reactors, click the General Reactors icon to open the General Reactors object palette. In the General Reactors object palette, double-click on the appropriate reactor operation icon. The property view for the selected Reactor operation appears. 8.2 CSTR/General Reactors Property View The CSTR and General Reactors property view contains the following tabs: • Design • Reactions • Rating • Worksheet • Dynamics Figure 8.1 CSTR icon General Reactors icon General Reactors object palette Conversion Reactors icon Equilibrium Reactors icon Gibbs Reactor icon Yield Shift Reactors icon8-5 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-6 CSTR/General Reactors Property ww Th8.2.1 Design Tab The Design tab contains several pages, which are briefly described in the table below. Connections Page The Connections page, is the same for both the CSTR and the General Reactors. Page Description Connections Connects the feed, product, and energy streams to the reactor. For more information, refer to the section below. Parameters Sets heat transfer and pressure drop parameters for the reactor. User Variables Enables you to create and implement your own user variables for the current operation. Notes Allows you to add relevant comments which are exclusively associated with the unit operation. Figure 8.2 For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information on the Notes page, refer to Section 1.3.5 - Notes Page/Tab.8-6 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-7 ww ThThe Connections page consists of the following objects described in the table below. Parameters Page The Parameters page allows you to specify the pressure drop, vessel volume, duty, and solving behaviour. Object Input Required Name Contains the name of the reactor. You can edit the name of the reactor at any time by typing in a new name in the Name field. Inlets / Feed Streams Connects a single feed or multiple feed streams to the reactor. You can either type in the name of the stream or if you have pre-defined your stream select it from the drop- down list. Vapour Outlet Connects the vapour product stream to the reactor. You can either type in the name of the stream or if you have pre- defined your stream select it from the drop-down list. At least one product stream is required. Liquid Outlet / Product Stream Connects the liquid product stream to the reactor. You can either type in the name of the stream or if you have pre- defined your stream select it from the drop-down list. Energy (Optional) Connects or creates an energy stream if one is required for the operation. Fluid Package Enables you to select a fluid package to be associated to the reactor. Figure 8.38-7 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-8 CSTR/General Reactors Property ww ThObject Description Delta P / Pressure Drop Contains the pressure drop across the vessel. The pressure drop is defined as: (8.1) where: P = vessel pressure Pv = pressure of vapour product stream Pl = pressure of liquid product stream Pfeed = pressure of feed stream (assumed to be the lowest pressure of all the feed streams) = pressure drop in vessel (Delta P) The default pressure drop across the vessel is zero. The vessel pressure is used in the reaction calculations. Duty If you have attached an energy stream, you can specify whether it is to be used for heating or for cooling by selecting the appropriate radio button. You also have a choice of specifying the applied duty, or having HYSYS calculate the duty. For the latter case, you must specify an outlet temperature for a reactor product stream. The steady state Reactor energy balance is defined below: (8.2) where: Duty = heating (+ve) or cooling (-ve) by the optional energy stream Hvapour = heat flow of the vapour product stream Hliquid = heat flow of the liquid product stream Hfeed = heat flow of the feed stream(s) The enthalpy basis used by HYSYS is equal to the ideal gas enthalpy of formation at 25°C and 1 atm. As a result, the heat of reaction calculation is amalgamated into any product/reactant enthalpy difference. ΔP Pfeed Pv– Pfeed Pl P Pv Pl== –= = ΔP Duty Hvapour Hliquid Hfeed–+=8-8 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-9 ww ThHeating /Cooling If you change from Heating to Cooling (or vice versa), the magnitude of the energy stream does not change. However, the sign changes in the energy balance. For Heating, the duty is added. For Cooling, the duty is subtracted. Volume The total volume of the vessel and is user specified. While not necessarily required for solving Conversion, GIBBS or Equilibrium reactors in Steady State mode, this value must be entered for CSTR. The vessel volume, together with the liquid level set point, define the amount of holdup in the vessel. The amount of liquid volume or holdup in the vessel at any time is given by the following expression: (8.3) where: PV(%Full) = liquid level in the vessel The vessel volume is necessary when modeling reactors in steady state, as it determines the residence time. Liquid Level Displays the liquid level of the reactor expressed as a percentage of the Full Vessel Volume. Liquid Volume Not set by the user, this value is calculated from the product of the volume (vessel volume) and liquid level fraction. It is only active when the Volume field contains a valid entry. Act as a Separator When Cannot Solve Only available for Conversion and Equilibrium reactors, this option allows you to operate the reactor as a simple 2 phase separator whenever the reactor does not solve. Single Phase Allows you to specify a single phase reaction. Otherwise HYSYS considers it a vapour-liquid reaction. Type Only available for the Gibbs reactor, you have two options for the type of reactor you want: • Separator. A two phase Gibbs Reactor. • Three Phase. A three phase Gibbs Reactor. Object Description Holdup Vessel Volume PV %Full( ) 100 ----------------------------×=8-9 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-10 CSTR/General Reactors Property ww Th8.2.2 Conversion Reactor Reactions Tab The Conversion Reactor is a vessel in which conversion reactions are performed. You can only attach reaction sets that contain conversion reactions. Each reaction in the set proceeds until the specified conversion is attained or until a limiting reactant is depleted. The Reactions tab, consists of the following pages: • Details • Results Details Page You can attach the reaction set to the operation and specify the conversion for each reaction in the set on the Details page. The reaction set can contain only conversion reactions. Figure 8.4 Conversion Reactor icon Refer to Section 5.3.2 - Conversion Reaction in the HYSYS Simulation Basis guide for details on creating Conversion Reaction Sets and Conversion Reactions.8-10 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-11 ww ThThe Details page consists of four objects as described in the table below. Stoichiometry Radio Button When you select the Stoichiometry radio button, the Stoichiometry Info group appears. The Stoichiometry Info group allows you to examine the components involved in the selected reaction, their molecular weights as well as their stoichiometric coefficients. Object Description Reaction Set Allows you to select the appropriate conversion reaction set. Reaction You must select the appropriate conversion reaction from the selected Reaction Set. View Reaction button Opens the Reaction property view for the reaction currently selected in the Reaction drop-down list. The Reaction property view allows you to edit the reaction. [Radio buttons] The three radio buttons on the Details page are: • Stoichiometry • Basis • Conversion The three radio buttons allow you to toggle between the Stoichiometry group, the Basis group or the Conversion group (each group is described in the following sections). Figure 8.5 The Balance Error (for the reaction stoichiometry) and the Reaction Heat (Heat of Reaction at 25°C) are also shown for the current reaction.8-11 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-12 CSTR/General Reactors Property ww ThBasis Radio Button When you select the Basis radio button, the Basis group appears. In the Basis group, you can view the base component, the conversion, and the reaction phase for each reaction in the reaction set. Conversion Radio Button When you select the Conversion radio button, the Fractional Conversion Equation group appears. The Fractional Conversion Equation group allows you to implement a conversion model based on the Conversion(%) equation listed. Figure 8.6 Figure 8.7 In the Fractional Conversion Equation group, parameters shown in red or blue colour indicate that the variable can be cloned.8-12 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-13 ww ThThe parameters for the attached conversion reaction(s) can be cloned as local variables belonging to the Conversion Reactor. Therefore, you can either use the parameters specified in the reaction(s) from the attached reaction set by clicking the Use Default checkbox or specifying locally the values within the Fractional Conversion Equation group. View Reaction Button When you click the View Reaction button, the Conversion Reaction property view of the reaction currently selected in the Reaction drop-down list appears. Any changes made to the Conversion Reaction property view are made globally to the selected Reaction and any Reaction Sets which contain the Reaction. For example, if any change is made to the reaction shown in the figure above, the change is carried over to every other instance in which this Reaction is used. It is therefore recommended that changes which are Reactor specific (in other words, changes which are only meant to affect one Reactor) are made within the Reactions tab. Figure 8.88-13 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-14 CSTR/General Reactors Property ww ThResults Page The Results page displays the results of a converged reactor. The page consists of the Reactor Results Summary group which contains two radio buttons: • Reaction Extents • Reaction Balance The type of results displayed on the Results page depend on the radio button selected. Reaction Extents Radio Button When the Reaction Extents radio button is selected, the Results page appears as shown in the figure below. You can change the specified conversion for a reaction directly on this page. Figure 8.98-14 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-15 ww ThThe Reactor Results Summary group displays the following results for a converged reactor: Notice that the actual conversion values do not match the specified conversion values. Rxn-3 proceeds first and is halted when a limiting reactant is exhausted. The sum of the specified conversions for Rxn-1 and Rxn-2 is 100%, so all of the remaining base component can be consumed, provided a limiting reactant is not fully consumed beforehand. All of the base component is consumed, and this is reflected in the actual conversion totalling 100%. Result Field Description Rank Displays the current rank of the reaction. For multiple reactions, lower ranked reactions occur first. When there are multiple reactions in a Reaction Set, HYSYS automatically ranks the reactions. A reaction with a lower ranking value occurs first. Each group of reactions of equal rank can have an overall specified conversion between 0% and 100%. Actual % Conversion Displays the percentage of the base component in the feed stream(s) which has been consumed in the reaction. Base Component The reactant to which the calculation conversion is based on. Rxn Extent Lists the molar rate consumption of the base component in the reaction divided by its stoichiometric coefficient appeared in the reaction. Any changes made to the global reaction affect all Reaction Sets to which the reaction is attached, provided local changes have not been made.8-15 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-16 CSTR/General Reactors Property ww ThReaction Balance Radio Button When the Reaction Balance radio button is selected, the Reaction Balance option provides an overall component summary for the Conversion Reactor. All components which appear in the fluid package are shown here. Values appear after the solution of the reactor has converged. The Total Inflow rate, the Total Reacted rate and the Total Outflow rate for each component are provided on a molar basis. Negative values indicate the consumption of a reactant, while positive values indicate the appearance of a product. Figure 8.108-16 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-17 ww Th8.2.3 CSTR Reactions Tab The CSTR is a vessel in which Kinetic, Heterogeneous Catalytic, and Simple Rate reactions can be performed. The conversion in the reactor depends on the rate expression of the reactions associated with the reaction type. The inlet stream is assumed to be perfectly (and instantaneously) mixed with the material already in the reactor, so that the outlet stream composition is identical to that of the reactor contents. Given the reactor volume, a consistent rate expression for each reaction and the reaction stoichiometry, the CSTR computes the conversion of each component entering the reactor. On the Reactions tab, you can select a reaction set for the operation. You can also view the results of the solved reactor including the actual conversion of the base component. The actual conversion is calculated as the percentage of the base component that was consumed in the reaction. where: X = actual % conversion NAin = base component flowrate into the reactor NAout = base component flowrate (same basis as the inlet rate) out of the reactor The Reactions tab contains the following pages: • Details • Results (8.4) For more information on Kinetic, Heterogeneous Catalytic and Simple Rate reactions, refer to Chapter 5 - Reactions in the HYSYS Simulation Basis guide. CSTR icon X NAin NAout – NAin --------------------------- 100%×=8-17 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-18 CSTR/General Reactors Property ww ThDetails Page The Details page allows you to attach the appropriate reaction set to the operation. As mentioned earlier in this section, the selected reaction set can contain only Kinetic, Heterogeneous Catalytic, and Simple Rate reactions. The page consists of four objects, which are described in the table below. Figure 8.11 Object Description Reaction Set Allows you to select the reaction set you want to use in the reactor. Reaction Allows you to select the reaction you want to use in the reactor. View Reaction Opens the Reaction property view for the selected Reaction. This allows you to edit the reaction globally. Specifics Toggles between the Stoichiometry group or the Basis group (the groups are described in the following sections).8-18 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-19 ww ThStoichiometry Radio Button When you select the Stoichiometry radio button, the Stoichiometry group appears. The Stoichiometry group allows you to examine the components involved in the currently selected reaction, their molecular weights as well as their stoichiometric coefficients. Basis Radio Button When you select the Basis radio button, the Basis group appears. In the Basis group, you can view the base component, the reaction rate parameters (for example A, E, ß, A’, E’, and ß’) and the reaction phase for each reaction in the attached set. Figure 8.12 The Balance Error (for the reaction stoichiometry) and the Reaction Heat (Heat of Reaction at 25°C) are also shown for the current reaction. Figure 8.138-19 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-20 CSTR/General Reactors Property ww ThYou can view the properties for a specific reaction by selecting the reaction from the Reaction drop-down list, and its data appears in the Basis group. Changes can be made to the reaction rate parameters (frequency factor, A, activation energy, E, and ß), but these changes are reflected only in the active reactor. The changes do not affect the global reaction. To return the global reaction values, select the appropriate Use Default checkbox. For instance, if you have made a change to the forward reaction activation energy (E), the Use Default E checkbox is inactive. Select this checkbox to return to the global E value. Results Page The Results page displays the results of a converged reactor. The page is made up of the Reaction Results Summary group which contains two radio buttons: • Reaction Extents • Reaction Balance Reaction Extents Radio Button When you select the Reaction Extents radio button, the Reaction Extents option displays the following results for a converged reactor: Result Field Description Actual % Conversion Displays the percentage of the base component in the feed stream(s) which has been consumed in the reaction. Base Component The reactant to which the conversion is applied. Rxn Extent Lists the molar rate consumption of the base component in the reaction divided by its stoichiometirc coefficient appeared in the reaction.8-20 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-21 ww ThReaction Balance Radio Button When you select the Reaction Balance radio button, the Reaction Balance option provides an overall component summary for the CSTR. All components which appear in the fluid package are shown here. Values appear after the solution of the reactor has converged. The Total Inflow rate, the Total Reacted rate and the Total Outflow rate for each component are provided on a molar basis. Negative values indicate the consumption of a reactant, while positive values indicate the appearance of a product. Figure 8.14 Figure 8.158-21 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-22 CSTR/General Reactors Property ww Th8.2.4 Equilibrium Reactor Reactions Tab The Equilibrium reactor is a vessel which models equilibrium reactions. The outlet streams of the reactor are in a state of chemical and physical equilibrium. The reaction set which you attach to the Equilibrium Reactor can contain an unlimited number of equilibrium reactions, which are simultaneously or sequentially solved. Neither the components nor the mixing process need be ideal, since HYSYS can compute the chemical activity of each component in the mixture based on mixture and pure component fugacities. You can also examine the actual conversion, the base component, the equilibrium constant, and the reaction extent for each reaction in the selected reaction set. The conversion, the equilibrium constant and the extent are all calculated based on the equilibrium reaction information which you provided when the reaction set was created. The Reactions tab contains the following pages: • Details • Results Details Page The Details page consists primarily of four radio buttons: • Stoichiometry • Basis • Ln[K] • Table Any changes made to the global reaction affect all reaction sets to which the reaction is attached, provided local changes have not been made. Refer to Section 5.3.3 - Equilibrium Reaction in the HYSYS Simulation Basis guide for details on creating and installing Equilibrium Reactions. Equilibrium Reactor icon8-22 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-23 ww ThStoichiometry Radio Button When you select the Stoichiometry radio button, the Stoichiometry Info group appears. The Stoichiometry group allows you to view the stoichiometric formula of the reaction currently selected in the Reaction drop-down list. The Balance Error (for the reaction stoichiometry) and the Reaction Heat (Heat of Reaction at 25°C) are also shown for the current reaction. Basis Radio Button When you select the Basis radio button, Basis group appears. Figure 8.16 Changes made to the global reaction affect all reaction sets which contain the reaction, and thus all operations to which the reaction set is attached. Figure 8.17 Refer to Section 5.3.3 - Equilibrium Reaction of the HYSYS Simulation Basis guide for details on Equilibrium Constant source.8-23 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-24 CSTR/General Reactors Property ww ThThe Basis group allows you to view or edit (locally) various information for each reaction in the reaction set including the: • Basis for the equilibrium calculations. • Phase in which the reaction occurs. • Temperature Approach of the equilibrium composition. The temperature range for the equilibrium constant, and the source for the calculation of the equilibrium constant is also shown. Keq Radio Button When you select the Keq radio button, the Ln(keq) group and K Table appears. The Ln(keq) group displays the Ln(Keq) relationship which may vary depending upon the Ln(K) Source value selected for the reaction. When you select the Ln(Keq) Equation radio button in the Ln(K) Source group, the parameters of the equilibrium constant equation appear. These values are either specified when the reaction was created or are calculated by HYSYS. If a fixed equilibrium constant was provided, it is shown here. Any of the parameters in the Ln(K) Equation group can be modified on this page. Changes made to the parameters only affect the selected reaction in the current reactor. After a change has been made, you can have HYSYS return the original calculated value by selecting the appropriate Use Default checkbox. Figure 8.18 Refer to Section 5.3.3 - Equilibrium Reaction of the HYSYS Simulation Basis guide for details on the Equilibrium Constant source. Refer to the section on the Basis Radio Button for more information.8-24 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-25 ww ThApproach Radio Button When you select the Approach radio button, the Fractional Approach group and the Temperature Approach group appear. For each reaction in the reaction set, a fractional approach equation as a function of temperature is provided. Any of the parameters in the Approach % equation can be modified on this page. Changes made to the parameters only affect the selected reaction in the current reactor. After a change has been made, you can have HYSYS return the original calculated value by selecting the appropriate Use Default checkbox. You can edit a reaction by clicking the View Reaction button. The property view for the highlighted reaction appears. Results Page The Results page displays the results of a converged reactor. The page is made up of the Results Summary group which contains two radio buttons: • Reaction Extents • Reaction Balance Figure 8.19 You can change the specified conversion for a reaction directly on this page. For more detailed information on equilibrium reactions, refer to Chapter 5 - Reactions in the HYSYS Simulation Basis guide.8-25 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-26 CSTR/General Reactors Property ww ThReaction Extents When you select the Reaction Extents radio button, the option displays the following results for a converged reactor: Figure 8.20 Result Field Description Actual % Conversion Displays the percentage of base component in the feed stream(s) which has been consumed in the reaction. The actual conversion is calculated as the percentage of the base component that was consumed in the reaction. (8.5) where: X = actual % conversion NAin = base component flowrate into the reactor NAout = base component flowrate (same basis as the inlet rate) out of the reactor Base Component The reactant to which the conversion is applied. X NAin NAout – NAin --------------------------- 100%×=8-26 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-27 ww ThReaction Balance When you select the Reaction Balance radio button, the Reaction Balance option provides an overall component summary for the Equilibrium Reactor. All components which appear in the component list related to the fluid package are shown here. Eqm Const. The equilibrium constant is calculated at the reactor temperature by the following: (8.6) where: T = reactor temperature, K A, B, C, D = equation parameters The four parameters in Equation (8.6) are calculated by HYSYS if they are not specified during the installation of the equilibrium reaction. The four parameters for each equilibrium equation are listed on the Rxn Ln(K) page. Rxn Extent Lists the molar rate consumption of the base component in the reaction divided by its stoichiometirc coefficient appeared in the reaction. Figure 8.21 Result Field Description Kln A B T -- C T DT+ln+ +=8-27 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-28 CSTR/General Reactors Property ww ThValues appear after the solution of reactor has converged. The Total Inflow rate, the Total Reacted rate, and the Total Outflow rate for each component are provided on a molar basis. Negative values indicate the consumption of a reactant, while positive values indicate the appearance of a product. 8.2.5 Gibbs Reactor Reactions Tab The Gibbs Reactor calculates the exiting compositions such that the phase and chemical equilibria of the outlet streams are attained. However, the Gibbs Reactor does not need to make use of a specified reaction stoichiometry to compute the outlet stream composition. The condition that the Gibbs free energy of the reacting system is at a minimum at equilibrium is used to calculate the product mixture composition. As with the Equilibrium Reactor, neither pure components nor the reaction mixture are assumed to behave ideally. The versatility of the Gibbs Reactor allows it to function solely as a separator, as a reactor which minimizes the Gibbs free energy without an attached reaction set or as a reactor which accepts equilibrium reactions. When a reaction set is attached, the Figure 8.22 Gibbs Reactor icon8-28 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-29 ww Thstoichiometry involved in the reactions is used in the Gibbs Reactor calculations. The Reactions tab contains the following pages: • Overall • Details Overall Page You must first select the reactor type on the Overall page. The objects that appear depend on the radio button you selected in the Reactor Type group. You can then attach a reaction set if necessary, and you can specify the vessel parameters on the Rating tab. Reactor Type Group In the Reactor Type group, select the radio button to define the method which HYSYS uses to solve the Gibbs Reactor. The table below describes the radio buttons. Radio Button Description Gibbs Reactions Only No reaction set is required as HYSYS solves the system by minimizing the Gibbs free energy while attaining phase and chemical equilibrium. You can also customize the maximum iteration number and equilibrium error tolerance in the Solving Option group. Specify Equilibrium Reactions Displays the Equilibrium Reaction Sets group. When a reaction set is attached, the Gibbs Reactor is solved using the stoichiometry of the reactions involved. The Gibbs minimization function uses the extents of the attached reactions while setting any unknowns to zero. NO Reactions (=Separator) The Gibbs Reactor is solved as a separator operation, concerned only with phase equilibrium in the outlet streams.8-29 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-30 CSTR/General Reactors Property ww ThDetails Page The Details page consists of one group, the Gibbs Reaction Details group. The group consists of two radio buttons: • Flow Specs • Atom Matrix The information that is viewable on the page depends on which of the two radio buttons is selected. Flow Specs Option When you select the Flow Specs radio button, a property view similar to the one in the figure below appears. You can view the component feed and product flowrates on a molar basis. You can also designate any of the components as inert or specify a rate of production for a component. Inert species are excluded from the Gibbs free energy minimization calculations. When the Inerts checkbox is selected for a component, values of 1 and 0 appear respectively in the associated Frac Spec and Fixed Spec cells, which indicates that the component feed flowrate equals the product flowrate. You may want to specify the rate of production of any component in your reactor as a constraint on the equilibrium composition. The component product flowrate is calculated as Figure 8.238-30 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-31 ww Thfollows, based on your input of a Frac Spec value and a Fixed Spec value: The Gibbs Reactor attempts to meet that flowrate in calculating the composition of the outlet stream. If the constraint cannot be met, a message appears alerting you to that effect. Atom Matrix Option When you select the Atom Matrix radio button, you can specify the atomic composition of any species for which the formula is unknown or unrecognized. The atomic matrix input form displays all components in the case with their atomic composition as understood by HYSYS. You have the option to enter the composition of an unrecognized compound or to correct the atomic composition of any compound. Total Prod = FracSpec x Total Feed + FixedSpec (8.7) Figure 8.248-31 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-32 CSTR/General Reactors Property ww Th8.2.6 Rating Tab The Rating tab includes the Sizing, Nozzles, and Heat Loss pages. Although most of the information on the three pages is not relevant when working in the Steady State mode, sizing a reactor plays an important role in calculating the holdup time. Sizing Page You can define the geometry of the unit operation on the Sizing page. Also, you can indicate whether or not the unit operation has a boot associated with it. If it does, then you can specify the boot dimensions. You are required to specify the rating information only when working with a dynamics simulation. Figure 8.25 For information on specifying information on the Sizing Page, refer to the HYSYS Dynamic Modeling guide.8-32 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-33 ww ThThe page consists of three main objects, which are described in the table below. Geometry Group The Geometry group contains five objects which are described in the table below. Object Description Geometry Allows you to specify the vessel geometry. This Reactor has a Boot When activated, the Boot Dimensions group appears. Boot Dimensions Allows you to specify the boot dimensions of the vessel. Object Description Cylinder / Sphere Toggles the shape of the vessel between Sphere and Cylinder. This affects the number of specifications required as well as the method of volume calculation. If you select the Cylinder, and you have specified the diameter and height; the vessel volume is calculated as: (8.8) If you select Sphere, and you have specified either the height or diameter; the vessel volume is calculated as: (8.9) where: Vreactor = volume of the reactor Vboot = volume of the boot Height, Diameter = values taken from the respective fields Orientation Allows you to select the orientation of the vessel. There are two options: • Horizontal. The ends of the vessels are horizontally orientated. • Vertical. The ends of the vessel are vertically orientated. Vreactor Diameter2 4 ---------------------------π Height×⎝ ⎠ ⎛ ⎞ Vboot+= Vreactor Height or Diameter( )3π 6 --------------------------------------------------------- Vboot+=8-33 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-34 CSTR/General Reactors Property ww ThThe Geometry group contains three fields: • Volume • Diameter • Height (or Length depending on orientation) Boot Dimensions If the reactor you are rating has a boot, you can include its volume in the total vessel volume by selecting the This Reactor has a Boot checkbox. The Boot Dimensions group appears. Volume Contains the total volume of the vessel. There are three possibilities for values in this field: • If the height and/or diameter have been entered, this field displays the value calculated using either Equation (8.8) or Equation (8.9). • If you enter a value into this field and either the height (length) or diameter is specified, HYSYS back calculates the other parameter using either Equation (8.8) or Equation (8.9). This is only possible with cylindrical vessels as spherical vessels have the height equal to the diameter. • If you enter a value into this field (and only this field) both the height (length) and diameter are calculated assuming a ratio of 3/2 (in other words, Height:Diameter ratio). Diameter Holds the diameter of the vessel. If the vessel is a Sphere, then it is the same value as the Height (Length). Height / Length Holds the height or length of the vessel depending on the vessels orientation (vertical or horizontal). If the vessel is a Sphere, then it is the same value as the diameter. If you specify the Volume then you are not required to specify the other two parameters as HYSYS calculates a Height (or Length) and Diameter assuming a ratio of Height to Diameter of 3/2. You can change the default ratio, by specifying one of the two dimensions (either Height or Diameter) and the third is automatically calculated using either Equation (8.8) or Equation (8.9). Object Description8-34 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-35 ww ThThe Boot Dimensions group consists of two fields, which are described in the table below. The volume of the boot is calculated using a simple cylindrical volume calculation: and the default boot volume is: The total Reactor volume can estimated using the boot diameter, boot height or the default boot volume. Nozzles Page The Nozzles page contains information regarding the elevation and diameter of the nozzles. Unlike steady state vessel operations, the placement of feed and product nozzles on a dynamic reactor operation has physical meaning. The composition of the exit stream depends on the exit stream nozzle’s location and diameter in relation to the physical holdup level in the vessel. • If the product nozzle is located below the liquid level in the vessel, the exit stream draws material from the liquid holdup. Field Description Boot Diameter The diameter of the boot. The default value is usually 1/3 the reactor diameter. Boot Height The height of the boot which is defaulted at 1/3 the reactor diameter (sphere) or 1/3 the reactor height or length (cylinder). (8.10) (8.11) VBoot π Boot Diameter 2 ----------------------------------⎝ ⎠ ⎛ ⎞ 2 Boot Height(× or Boot Length )= VBoot π Diameter 6 ------------------------⎝ ⎠ ⎛ ⎞ 2 Diameter 3 ------------------------×= π Diameter( )3 72 -----------------------------------= Refer to Section 1.3.6 - Nozzles Page for more information.8-35 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-36 CSTR/General Reactors Property ww Th• If the product nozzle is located above the liquid level, the exit stream draws material from the vapour holdup. • If the liquid level lies across a nozzle, the phase fraction of liquid in the product stream varies linearly with how far up the liquid is in the nozzle. Essentially, all vessel operations in HYSYS are treated similarly. The composition and phase fractions (in other words, fraction of each phase) of every product stream depends solely on the relative levels of each phase in the holdup and the location the product nozzles. Heat Loss Page The Heat Loss page allows you to specify which Heat Loss Model you want to implement, and to define the parameters associated with each model. 8.2.7 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. A vapour product nozzle does not necessarily produce pure vapour and a 3-phase separator may not produce two distinct liquid phase products from its product nozzles. The PF Specs page is relevant to dynamics cases only. For information refer to Heat Loss Page section in Chapter 10 - Separation Operations. Refer to Section 1.3.10 - Worksheet Tab for more information.8-36 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-37 ww Th8.2.8 Dynamics Tab If you are working exclusively in Steady State mode, you are not required to change any information on the pages accessible through this tab. Specs Page The Specs page contains information regarding initialization modes, vessel geometry, and vessel dynamic specifications. Model Details You can determine the composition and amount of each phase in the vessel holdup by specifying different initialization modes. HYSYS forces the simulation case to re-initialize whenever the initialization mode is changed. Figure 8.268-37 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-38 CSTR/General Reactors Property ww ThThe radio buttons in the Model Details group are described in the table below. The Enable Explicit Reaction Calculations is defaulted to be used for dynamic run reaction solver. The Lag Rxn Temperature is designed to speed up the dynamic run for the reaction solver when the run has to invoke the steady state reaction solver. Mathematically, when you select the Lag Rxn Temperature checkbox, the reaction solver flashes with the explicit Euler method. Otherwise, for a dynamic run, the steady state reaction solver always flashes with the implicit Euler methods which could be slow with many iterations. The Lag Rxn Temperature may cause some instability due to the nature of the explicit Euler method. But it must compromise with the dynamic step size. In the Model Details group, you can specify the vessel geometry parameters. • Vessel Volume • Vessel Diameter • Vessel Height (Length) • Vessel Geometry (Level Calculator) Initialization Mode Description Initialize from Products The composition of the holdup is calculated from a weighted average of all products exiting the holdup. A PT flash is performed to determine other holdup conditions. The liquid level is set to the value indicated in the Liq Volume Percent field. Dry Startup The composition of the holdup is calculated from a weighted average of all feeds entering the holdup. A PT flash is performed to determine other holdup conditions. The liquid level in the Liq Volume Percent field is set to zero. Initialize from User The composition of the liquid holdup in the vessel is user specified. The molar composition of the liquid holdup can be specified by clicking the Init Holdup button. The liquid level is set to the value indicated in the Liq Volume Percent field. The vessel geometry parameters can be specified in the same manner as those specified in the Geometry group for the Sizing page of the Rating tab.8-38 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-39 ww ThLiquid Volume Percent You can modify the level in the vessel at any time. HYSYS then uses that level as an initial value when the Integrator has started, depending on the initialization mode you selected. Fraction Calculator The Fraction Calculator determines how the level in the tank, and the elevation and diameter of the nozzle affects the product composition. The following is a description of the Fraction Calculator option: Use Levels and Nozzles.The nozzle location and vessel liquid level affect the product composition as detailed in the Nozzles Page of Section 8.2.6 - Rating Tab. Dynamic Specifications The frictional pressure loss at the feed nozzle is a dynamic specification in HYSYS. It can be specified in the Feed Delta P field. The frictional pressure losses at each product nozzle are automatically set to zero by HYSYS. If you want to model friction loss at the inlet and exit stream, it is suggested you add valve operations. In this case, flow into and out of the vessel is realistically modeled. The vessel pressure can also be specified. This specification can be made active by selecting the checkbox beside the Vessel Pressure field. This specification is typically not set since the The Fraction Calculator defaults to the correct mode for all unit operations and does not typically require any changing. It is recommended that you enter a value of zero in the Feed Delta P field because a fixed pressure drop in the vessel is not realistic for all flows.8-39 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-40 CSTR/General Reactors Property ww Thpressure of the vessel is usually a variable and determined from the surrounding pieces of equipment. Holdup Page The Holdup page contains information regarding the properties, composition, and amount of the holdup. The Vessel Levels group displays the following variables for each of the phases available in the vessel: • Level. Height location of the phase in the vessel. • Percent Level. Percentage value location of the phase in the vessel. • Volume. Amount of space occupied by the phase in the vessel. Stripchart Page The Stripchart page allows you to select and create default strip charts containing various variable associated to the operation. Figure 8.27 Refer to Section 1.3.3 - Holdup Page for more information. Refer to Section 1.3.7 - Stripchart Page/Tab for more information.8-40 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-41 ww ThHeat Exchanger Page The Heat Exchanger page allows you to select whether the reactor is heated, cooled, or left alone. You can also select the method used to heat or cool the reactor. The options available in the Heat Exchanger page depends on which radio button you select: • If you select the None radio button, this page is blank and you do not have to specify an energy stream in the Connections page (from the Design tab) for the reactor operation to solve. • If you select the Duty radio button, this page contains the standard heater or cooler parameters and you have to specify an energy stream in the Connections page (from the Design tab) for the reactor operation to solve. • The Tube Bundle radio button option is not available for the reactor operations. Figure 8.28 If you switch from Duty option to None option, HYSYS automatically disconnects the energy stream associated to the Duty options. Refer to Duty Radio Button for more information.8-41 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-42 Yield Shift Reactor ww Th8.3 Yield Shift Reactor The Yield Shift reactor unit operation supports efficient modeling of reactors by using data tables to perform shift calculations. The operation can be used for complex reactors where no model is available, or where models that are too computationally expensive. Theory There are two methods to configure the reaction in the Yield Shift reactor: Yield Only or Percent Conversion. Depending on what information you supply the reactor automatically use the appropriate equation to solve the reaction. Product Stream Mass Fractions The following equations are used to calculate the product stream mass fractions: • For Component Percent Conversion method: where: yk = mass fraction of component k in product stream xk = mass fraction of component k in feed stream convk = component type (reacting or non-reacting) for component k (8.12) The sum of the component mass fraction must equal one. yk xk 1 convk–( )× cur_yieldk convtotal×+=8-42 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-43 ww ThNC = number of components base_yieldk = base yield of component k NV = number of input variables NRi = number of ranges for each input variable i = base shift value for component k effi = efficiency for design variable i, the values are user- specified in the Efficiencies Page = minimum range value of dataset j of design variable i = maximum range value of dataset j of design variable i (8.13) (8.14) (8.15) (8.16) (8.17) The sum of the base shift values for all the components should equal zero. convtotal xk convk× k 0= NC ∑= cur_yieldk base_yieldk total_shiftk+= There are two methods to obtain the base yield value: • Calculate the value from raw data, see Design Data:Base Page. • Specify the value, see Base Yields Page. total_shiftk cur_adji j base_adji j–( ) base_shifti j( )k effi××[ ] j 0= NRi ∑ i 0= NV ∑= cur_adji j Max pi j min, Min pi j max, cur_valuei,( ),[ ]= base_adji j Max pi j min, Min pi j max, base_valuei,( ),[ ]= base_shifti j( )k pi j min, pi j max,8-43 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-44 Yield Shift Reactor ww Thcur_valuei = current value for design variable i base_valuei = base value for design variable i • For Yield Only Conversion method: where: yk = mass fraction of component k in product stream xk = mass fraction of component k in feed stream = total conversion value for the reaction base_yieldk = base yield of component k = total shift value, see Equation (8.15) If the range values are not specified, HYSYS assumes negative and positive infinity values for minimum and maximum range respectively. (8.18) The sum of the component mass fraction must equal one. (8.19) There are two methods to obtain the base yield value: • Calculate the value from raw data, see Design Data:Base Page. • Specify the value, see Base Yields Page. yk xk cur_yieldk conversiontotal×+= conversiontotal cur_yieldk base_yieldk total_shiftk+= total_shiftk8-44 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-45 ww Th8.3.1 Yield Shift Reactor Property View The Yield Shift Reactor property view contains the following tabs: • Design • Model Config • Composition Shift • Property Shift • Worksheet8-45 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-46 Yield Shift Reactor ww Th• Dynamics Figure 8.298-46 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-47 ww Th8.3.2 Design Tab The Design tab contains the options that enables you to configure the Yield Shift reactor. The options are grouped in the following pages: • Connections • Parameters • User Variables The User Variables page enables you to create and implement your own user variables for the current operation. • Notes The Notes page enables you to add relevant comments which are exclusively associated with the unit operation. Connections Page The Connections page enables you to configure the material and energy streams flowing in and out of the reactor. Figure 8.30 Object Description Name field Enables you to modify the name of the reactor. Fluid Pkg field Enables you to select the fluid package associated to the reactor. Feed Streams table Enables you to specify or select inlet streams flowing into the reactor. Product Stream field Enables you to specify or select an outlet stream flowing out of the reactor. For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information on the Notes page, refer to Section 1.3.5 - Notes Page/Tab.8-47 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-48 Yield Shift Reactor ww ThParameters Page The Parameters page allows you to specify the pressure drop of the reactor. The Pressure Drop field enables you to specify the pressure drop in the vessel of the reactor. The pressure drop is defined as: where: = pressure drop in vessel (Delta P) Pproduct = pressure of the product stream Pfeed = pressure of the feed stream, assumed to be the lowest pressure of all the feed streams The default pressure drop across the vessel is zero. Make-up Energy Stream (Optional) Enables you to connect or create a make-up energy stream if one is required for the operation. If you specify any heat adjustment for the reaction, HYSYS automatically creates a make-up energy stream to represent the heat transfer. Energy (Optional) Enables you to connect or create an energy stream if one is required for the operation. Figure 8.31 (8.20) Object Description ΔP Pfeed Pproduct–= ΔP8-48 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-49 ww Th8.3.3 Model Config Tab The Model Config tab contains the options for configuring the reactor. These options are split into the following pages: • Design Parameters • Design Variables • Heat of Reaction Design Parameters Page The Design Parameters page enables you to specify other design parameters that affect the reaction in the reactor. Figure 8.32 These parameters are optional and you do not have to supply any parameter information to get the reactor to solve. Object Description Name column Enables you to change the name of the selected design parameter. Value column Enables you to specify the design parameter value. Unit Type column Enables you to select the unit type for the design parameter. When a new parameter... checkbox Enables you to toggle between adding or not adding a new design variable every time a new design parameter is added.8-49 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-50 Yield Shift Reactor ww ThDesign Variables Page The Design Variable page enables you to insert, edit, and remove variables used in the reaction calculations for the reactor. Insert New Parameter button Enables you to add a new design parameter. Remove Selected Parameter button Enables you to remove the selected operation parameter in the Operating Parameters table. You can select multiple parameters by pressing and holding the CTRL or SHIFT key while selecting the parameters. Figure 8.33 Object Description Name column Enables you to modify the name of the design variable. Assoc Object column Displays the name of the object associated to the design variable. Variable column Displays the design variable type. Dataset No column Enables you to specify the number of data set/value is available for the design variable. On/Off checkbox Enables you to toggle between acknowledging or ignoring the design variable during calculation. A clear checkbox indicates you are ignoring the design variable. Insert Design Var button Enables you to add a design variable using the property view similar to the Variable Navigator property view. Object Description Refer to Section 1.3.9 - Variable Navigator Property View for more information.8-50 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-51 ww ThHeat of Reaction Page The Heat of Reaction page enables you to specify heat transfer that occurs during reaction. Edit Design Var button Enables you to change the selected design variable to a different variable. Remove Design Var button Enables you to remove the selected design variable from the reactor. Set Password button Enables you to set the password for the reactor. This button is only available if you have not set a password for the reactor. The password feature is available for users to protect the configuration data of the Yield Shift reactor. The password feature protects the proprietary property of the Yield Shift reactor configuration, while enables the reactor to be shared among other HYSYS users. Change Password button Enables you to change the password for the reactor. This button is only available if the reactor already contains a password. Figure 8.34 Object Description Adjusting Factor column Enables you to specify the heat transfer that occur for the associate component in the reactor. If you specify a value (other than zero) for the adjusting factor, HYSYS automatically creates a make- up energy stream to balance the heat transfer. Object Description8-51 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-52 Yield Shift Reactor ww Th8.3.4 Composition Shift Tab The Composition Shift tab contains options to specify the composition shift affected by the design variables. These options are split into the following pages: • Design Data: Base and Data • Base Yields • Base Shifts • Efficiencies • Results: Yields, Shift Extents, and Total Extents Design Data Page The Design Data page enables you to configure the yield of the reactor. The options are split into the following branches/pages: • Base • Data Amount of Reaction column Displays the rate of component that was consumed or generated during the reaction. Adjusted Duty Displays the amount of duty for the associate component. Figure 8.35 Object Description8-52 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-53 ww ThDesign Data:Base Page The Base page enables you to specify the design base values for the design variables, feed stream, and product stream. These values are use to calculate the base yield values of the components. Figure 8.36 You can calculate base yield values using the options in the Base page or specify the base yield values in the Base Yield page. Object Description Design Base Value column Enables you to specify the design base values for the associate design variables. Use percent conversion radio button Enables you to model the reactor based on percent conversion specifications. Use yield only radio button Enables you to model the reactor based on yield specifications. Feed column Displays the composition of the feed stream. You can edit the composition of the stream by entering an new value in any of the cells. Product column Displays the composition of the product stream. You can edit the composition of the stream by entering an new value in any of the cells. Base Conversion column Enables you to specify the base conversion value for each component in percent value.8-53 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-54 Yield Shift Reactor ww ThTo change the composition of a stream: 1. In the Component Base Compositions of Feed and Product group, select the stream you want to edit by clicking on a cell associated to the stream. 2. Click the Edit Compositions button. The component composition property view appears. 3. In the appropriate cell, enter the composition value for each component. • You can modify the composition basis of the stream by selecting the appropriate radio button in the Composition Basis group. • You can click the Erase button to remove all the composition values. • You can click the Normalize button to shift all the composition values so that the total value equals 1. • You can click the Cancel button to exit the component composition property view without accepting any of the changes made. 4. Click the OK button to accept the modified composition values. Edit Composition button Enables you to edit the composition of the selected stream. Change Comp Basis button Enables you to change the composition basis of the selected stream. Figure 8.37 Object Description8-54 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-55 ww ThTo change the composition basis of a stream: 1. In the Component Base Compositions of Feed and Product group, select the stream you want to edit by clicking on a cell associated to the stream. 2. Click the Change Comp Basis button. The composition basis property view appears. 3. Select the composition basis you want by clicking the appropriate radio button. You can click the Cancel button to exit the composition basis property view without accepting any of the changes made. 4. Click the Accept button to accept the new selection. Calculating Base Yield Values • Calculating the base yield values using percent conversion: where: = base yield value for component k of dataset j = product stream mass fraction for component k of dataset j Figure 8.38 (8.21) base_yieldk j yk j xk j 1 convk base–( )×– xk j convk base× k 0= NC ∑ --------------------------------------------------------= base_yieldk j yk j 8-55 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-56 Yield Shift Reactor ww Th = feed stream mass fraction for component k of dataset j = base conversion percentage value for component k NC = number of components • Calculating the base yield values using yield only: where: = base yield value for component k of dataset j = product stream mass fraction for component k of dataset j = feed stream mass fraction for component k of dataset j Design Data:Datasets Page The Datasets page enables you to specify the data set values for the design variables, feed stream, and product stream. These values are used to calculate the component shift for each data set of each design variable. (8.22) Figure 8.39 xk j convk base base_yieldk j yk j xk j–= base_yieldk j yk j xk j 8-56 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-57 ww ThTo change the stream composition of a data set: 1. In the Data Sets of Design Variables group, select the appropriate radio button to modify the feed or product stream. 2. In the Design Variables list, select the design variable associated to the stream you want to edit. 3. In the stream table, select the data set you want to modify. 4. Click the Edit Selected Dataset button. You can calculate base shift values using the options in the Dataset page or specify the base shift values in the Base Shifts page. Object Description Feed radio button Enables you to access and modify the composition of the feed stream. Product radio button Enables you to access and modify the composition of the product stream. Design Variables list Enables you to access and modify the data set values of the selected variable. Dataset columns Enables you to specify the selected design variable value for the associate data set. Feed Dataset column Enables you to specify the feed stream composition for the associate data set. This column is only available if the Feed radio button is selected. Product Dataset column Enables you to specify the product stream composition for the associate data set. This column is only available if the Product radio button is selected. Edit Selected Dataset button Enables you to edit the stream composition of the selected data set. Erase All Datasets button Deletes all the stream composition values for all data sets. Change Comp Base button Enables you to change the composition basis of the selected data set.8-57 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-58 Yield Shift Reactor ww ThThe component composition property view appears. 5. In the appropriate cell, enter the composition value for each component. • You can modify the composition basis of the stream by selecting the appropriate radio button in the Composition Basis group. • You can click the Erase button to remove all the composition values. • You can click the Normalize button to shift all the composition values so that the total value equals 1. • You can click the Cancel button to exit the component composition property view without accepting any of the changes made. 6. Click the OK button to accept the modified composition values. To change the composition basis of a data set: 1. In the Data Sets of Design Variables group, select the appropriate radio button to modify the feed or product stream. 2. In the Design Variables list, select the design variable associated to the stream you want to edit. 3. In the stream table, select the data set you want to modify. 4. Click the Change Comp Basis button. Figure 8.408-58 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-59 ww ThThe composition basis property view appears. 5. Select the composition basis you want by clicking the appropriate radio button. You can click the Cancel button to exit the composition basis property view without accepting any of the changes made. 6. Click the Accept button to accept the new selection. Calculating Component Shift The following equation is used to calculate the component shift value for the dataset of each variable. where: = component shift value for component k of dataset j = yield value for component k of dataset j+1 = yield value for component k of dataset j = maximum design variable value for dataset j+1 = minimum design variable value for dataset j Figure 8.41 (8.23)comp_shiftk j yieldk j 1+ yieldk j– input_varj 1+ input_varj– -------------------------------------------------------------= comp_shiftk j yieldk j 1+ yieldk j input_varj 1+ input_varj8-59 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-60 Yield Shift Reactor ww ThBase Yields Page The Base Yields page enables you to specify the base yield values of each component in the reactor. Figure 8.42 If you had already specify the yield values in the Design Data page, the base yield values in the Base Yield page will appear black and is write protected. You can calculate base yield values using the options in the Base page or specify the base yield values in the Base Yield page. Object Description Use percent conversion radio button Enables you to select the percent conversion yield type for the reactor calculation. Use yield only radio button Enables you to select the specify yield value type for the reactor calculation. Base Yield column Enables you to specify the base yield values for the components in the reactor. Conversion [%] column Enables you to specify the conversion percent value for the reactor. This column is only available is the Use percent conversion radio button is selected.8-60 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-61 ww ThBase Shifts Page The Base Shifts page enables you to specify the shift values for the design parameters. Total Conversion [%] Enables you to specify in percentage the amount of components in the feed stream was converted in the reactor. This column is only available is the Use yield only radio button is selected. Edit Base Yield button Enables you to edit the component base yield values for the reactor. This button is only active if you have not specified any yield values in the Design Data tab. Figure 8.43 The variables in this page cannot be modified if you have already specified the values in the Design Data page. You can calculate base shift values using the options in the Dataset page or specify the base shift values in the Base Shifts page. Object Description Min row Enables you to specify the minimum value for the associate design parameter data set. Max row Enables you to specify the maximum value for the associate design parameter data set. Current row Displays the current value for the associate design parameter data set. Object Description8-61 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-62 Yield Shift Reactor ww ThEfficiencies Page The Efficiencies page enables you to specify the percentage efficiency values of the selected design parameters. The efficiency value specified in this page is used in Equation (8.15) to calculate the total shift values. Base row Enables you to specify the base value for the associate design parameter data set. Cur_adj row Displays the adjusted current variable value, see Equation (8.16). Base_adj row Displays the adjusted base variable value, see Equation (8.17). Component rows Enables you to specify the component composition value for the associate design parameter data set. Edit Selected Base Shift button Enables you to edit the composition of the selected design parameter data set. Normalize All Base Shifts button Enables you to normalize the base shifts sum to 0. Erase All Base Shifts button Enables you to delete composition value for all the design parameter data sets. Figure 8.44 Object Description8-62 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-63 ww ThResults Page The Results page contains the calculated values from the specified parameters. The information is split into the following pages: • Yields • Shift Extents • Total Extents Results:Yields Page The Yields page displays the base yield, total shift, and current yield of all the components in the reactor. Figure 8.45 Figure 8.468-63 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-64 Yield Shift Reactor ww ThResults:Shift Extents Page The Shift Extents page displays the component composition shift values for each data set. Results:Total Extents Page The Total Extents page displays the component extent value for the base, design parameters, and total extent values. Figure 8.47 Figure 8.488-64 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-65 ww Th8.3.5 Property Shift Tab The Property Shift tab contains options to specify the property shift of the design variables. These options are split into the following pages: • Properties • Design Data: Base and Data • Base Shifts • Efficiencies • Results: Shift Extents and Total Extents Calculating Property Shift The following equation is used to calculate the property shift: where: cur_prop = current property shift value base_prop = base property value NV = number of input variables NRi = number of ranges for each input variable i effi = efficiency value for design variable i, the values are user-specified in the Efficiencies Page (8.24) (8.25) (8.26) (8.27) cur_prop base_prop total_shift+= total_shift cur_adji j base_adji j–( ) effi×[ ] j 0= NRi ∑ i 0= NV ∑= cur_adji j Max pi j min, Min pi j max, cur_valuei,( ),[ ]= base_adji j Max pi j min, Min pi j max, base_valuei,( ),[ ]=8-65 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-66 Yield Shift Reactor ww Th = minimum range value of each dataset j from design variable i = maximum range value of each dataset j from design variable i cur_valuei = current value for design variable i base_valuei = base value for design variable i Properties Page The Properties page enables you to insert or remove yield shift properties. If the range values are not specified, HYSYS assumes negative and positive infinity values for minimum and maximum range respectively. Figure 8.49 Object Description Name column Enables you to change the name of the selected property. Value column Enables you to specify the property value. Unit Type column Enables you to select the property unit type. pi j min, pi j max,8-66 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-67 ww ThDesign Data Page The Design Data page enables you to configure the selected design parameter and data set. The options are split into the following branches/pages: • Base • Datasets Insert New Property button Enables you to add a new property. Remove Selected Property button Enables you to remove the selected property in the table. You can select multiple properties by pressing and holding the CTRL or SHIFT key while selecting the properties. Figure 8.50 Object Description8-67 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-68 Yield Shift Reactor ww ThDesign Data: Base Page The Base page enables you to specify the base value for the design variables. Design Data:Datasets Page The Datasets page enables you to specify the raw data set values for the design variables and properties. These property values are used to calculate the base shift value. Figure 8.51 Figure 8.528-68 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-69 ww ThCalculating Property Shift Values The following equation is used to calculate the base shift for dataset j of each variable for property shift. where: = base shift value for component k of dataset j = property shift value for component k of dataset j+1 = property shift value for component k of dataset j = maximum design variable value for dataset j+1 = minimum design variable value for dataset j Object Description Design Variables list Enables you to access and modify the data set values of the selected variable. Dataset columns Enables you to specify the selected design variable value and the selected property values for the associate data set. You can calculate base shift values using the options in the Dataset page or specify the base shift values in the Base Shifts page. (8.28) The above equation is used when only raw data is supplied. base_shiftk j propk j 1+ propk j– design_varj 1+ design_varj– --------------------------------------------------------------------= base_shiftk j propk j 1+ propk j design_varj 1+ design_varj8-69 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-70 Yield Shift Reactor ww ThBase Shifts Page The Base Shifts page enables you to configure the shift range and shift property value for the reactor. Figure 8.53 You cannot modify the values in the Base Shifts page if you have already specified the values in the Properties and Design Data pages. You can calculate base shift values using the options in the Dataset page or specify the base shift values in the Base Shifts page. Object Description Min row Enables you to specify the minimum value for the associate design parameter data set. Max row Enables you to specify the maximum value for the associate design parameter data set. Current row Displays the current value for the associate design parameter data set. Base row Enables you to specify the base value for the associate design parameter data set. Cur_adj row Displays the adjusted current variable value, see Equation (8.26). Base_adj row Displays the adjusted base variable value, see Equation (8.27). Properties rows Enables you to specify the shift property value for the associate design parameter data set.8-70 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-71 ww ThEfficiencies Page The Efficiencies page enables you to specify the percentage efficiency values of the selected design parameters. The efficiency value specified in this page is used in Equation (8.25) to calculate the total shift values. Results Page The Results page contains the calculated values for the reactor. Figure 8.54 Figure 8.558-71 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-72 Yield Shift Reactor ww ThThe information is split into the following branches/pages: • Shift Extents • Total Extents Results:Shift Extents Page The Shift Extents page displays the property shift values associated to the design parameters. Results:Total Extents Page The Total Extents page displays the property values for the base, design parameter, and current. Figure 8.56 Figure 8.578-72 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-73 ww Th8.3.6 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. 8.3.7 Dynamics Tab If you are working exclusively in Steady State mode, you are not required to change any information on the pages accessible through this tab. The Dynamics tab for Yield Shift Reactor operation has only one page: Specs. Specs Page The Specs page contains the option to set the reactor vessel volume. The PF Specs page is relevant to dynamics cases only. Figure 8.58 Refer to Section 1.3.10 - Worksheet Tab for more information.8-73 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-74 Plug Flow Reactor ww Th8.4 Plug Flow Reactor The Plug Flow Reactor (PFR), also known as the Tubular Reactor, generally consists of a bank of cylindrical pipes or tubes. The flow field is modeled as plug flow, implying that the stream is radially isotropic (without mass or energy gradients). This also implies that axial mixing is negligible. As the reactants flow the length of the reactor, they are continually consumed, hence, there is an axial variation in concentration. Since reaction rate is a function of concentration, the reaction rate also varies axially (except for zero-order reactions). To obtain the solution for the PFR (axial profiles of compositions, temperature, and so forth), the reactor is divided into several subvolumes. Within each subvolume, the reaction rate is considered to be spatially uniform. A mole balance is done in each subvolume j: Figure 8.59 (8.29)Fj0 Fj– rj Vd V ∫+ Njd dt -------=8-74 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-75 ww ThBecause the reaction rate is considered spatially uniform in each subvolume, the third term reduces to rjV. At steady state, the right side of this balance equals zero, and the equation reduces to: Newton’s Method The default calculation process for solving the PFR is Newton’s method. In this method, the PFR is divided into segments (subvolumes) that behave like well-mixed, stirred tank reactors. For an adiabatic reactor in the solution step, the outer loop converges on enthalpy and temperature, and the inner loop converges on composition. To reduce the convergence time to solve the PFR, you can specify the reactor outlet stream temperature and reactor duty to eliminate the outer loop calculation. However, to model an adiabatic reactor, you must manually converge on the outlet stream temperature. In the inner loop, the program solves the outlet fluid composition for an assumed value of outlet fluid temperature using a Newton strategy. In this solution strategy, the component mass balances are solved using the following equation: where: Fk,i = kth component’s inlet flowrate Fk,o = outlet flowrate for the kth component rk,n = reaction rate of the kth component in nth reaction (8.30) (8.31) Fj Fj0 rjV+= ∑−= 0 ,,, N nkokjk rVFF for all k 8-75 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-76 Plug Flow Reactor ww ThV = volume containing the reactions; in the case of PFR, this is the reactor segment volume rk,n is typically a complex function of the composition of the outlet fluid, so the set of equations are non-linear. In the inner loop, a fixed tolerance of 1.0e-6 is used on the sum of residuals for the equations. The outer loop then converges on the enthalpy of the outlet fluid. The new temperature in the outer loop is computed using a line-search strategy. The temperature is first bracketed at points T1 and T2. where: Ho,spec = specified enthalpy of the outlet stream Ho,calc = calculated enthalpy of the outlet stream at temperature T Hi,spec = specified enthalpy of the inlet stream D = specified duty entering the reactor T = temperature • If T2 > Tnew > T1 and Tnew - T1 < T2 - Tnew, then Tnew becomes the next T1. • If T2 > Tnew > T1 and Tnew - T1 > T2 - Tnew, then Tnew becomes the next T2. • If Tnew < T1, then Tnew becomes the next T1. • If Tnew > T2, then Tnew becomes the next T2. (8.32) Tnew HT1 HT1 HT2+ ------------------------- T1 T2–( ) T1+= ( )1 , , 1T o spec o calc T H H H= − ( )2 , , 2T o spec o calc T H H H= − , ,o spec i specH H D= +8-76 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-77 ww ThThe convergence criteria for the outer loop is: where: = outer loop tolerance (default value is 1.0e-5) The outer loop tolerance can be changed in the Advanced property view of the Reaction set. Refer to the Reactions Set Property View in the Aspen HYSYS Simulation Basis Guide for more information. 8.4.1 Adding a Plug Flow Reactor (PFR) There are two ways that you can add a PFR to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Reactors radio button. 3. From the list of available unit operations, select Plug Flow Reactor. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the Plug Flow Reactor icon. (8.33), , , , o spec o calc o spec o calc H H H H δ − < + δ Plug Flow Reactor icon8-77 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-78 Plug Flow Reactor (PFR) Property ww ThThe PFR property view appears. 8.5 Plug Flow Reactor (PFR) Property View The Plug Flow Reactor (PFR) property view contains the following tabs: • Design • Reactions • Rating • Worksheet • Performance • Dynamics Figure 8.608-78 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-79 ww Th8.5.1 PFR Design Tab The Design tab of the PFR contains several pages, which are briefly described in the table below. Connections Page You can specify the name of the reactor, the feed(s) stream, product stream, and energy stream on the Connections page. Page Input Required Connections Attaches the feed and product streams to the reactor. Refer to the section below for more information. Parameters Allows you to specify the parameters for the pressure drops and energy streams. Heat Transfer Allows you to specify the heat transfer parameters. User Variables Allows you to create and implement User Variables. Notes Allows you to add relevant comments which are exclusively associated with the unit operation. Figure 8.61 If you do not provide an energy stream, the operation is considered to be adiabatic. 8-79 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-80 Plug Flow Reactor (PFR) Property ww ThThe table below describes the objects on the Connections page. Parameters Page You can instruct HYSYS on the calculations for the pressure drop and heat transfer, and also decide whether the operation is included in the calculation on the Parameters page. Pressure Drop Parameters Group In the Pressure Drop Parameters group, you can select one of the available radio buttons for the determination of the total pressure drop across the reactor. Object Input Required Inlets The reactor feed stream. Outlet The reactor product stream. Energy (Optional) You are not required to provide an energy stream, however under those circumstances HYSYS assumes that the operation is adiabatic. Figure 8.628-80 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-81 ww ThThe radio buttons are described in the table below. Radio Button Description User Specified Select this radio button to specify a pressure drop in the Delta P field. Ergun Equation HYSYS uses the Ergun equation to calculate the pressure drop across the PFR. The equation parameters include values which you specify for the PFR dimensions and feed streams: (8.34) where: = pressure drop across the reactor gc = Newton's-law proportionality factor for the gravitational force unit L = reactor length = particle sphericity Dp = particle (catalyst) diameter = fluid density = superficial or empty tower fluid velocity = void fraction = fluid viscosity If you select the Ergun Equation radio button for a PFR with no catalyst (solid), HYSYS sets = 0. When you select the Ergun Equation radio button, the Delta P field changes colour from blue to black, indicating a value calculated by HYSYS. ΔPgc L ------------ ϕsDp ρV2 ------------ ε3 1 ε– ----------- 150 1 ε–( ) ϕsDpVρ μ⁄ --------------------------- 1.75+= ΔP ϕs ρ V ε μ ΔP8-81 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-82 Plug Flow Reactor (PFR) Property ww ThDuty Parameters Group For the PFR heat transfer calculations, you can select one of the radio buttons described in the table below. You can specify whether the energy stream is Heating or Cooling by selecting the appropriate radio button. This does not affect the sign of the duty stream. Rather, if the energy stream is Heating, then the duty is added to the feed. If Cooling is chosen, the duty is subtracted. Heat Transfer Page The format of the Heat Transfer page depends on your selection in the SS Duty Calculation Option group. There are two radio buttons: • Formula • Direct Q Value Radio Button Description Formula HYSYS calculates the energy stream duty after you specify further heat transfer information on the Heat Transfer Page. The two fields below the radio buttons show the Energy Stream, which is attached on the Connections page, and the Calculated Duty value. Direct Q Value You can directly specify a duty value for the energy stream. Your selection in the SS Duty Calculation Option group is also transferred to the Heat Transfer group on the Parameters page.8-82 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-83 ww ThDirect Q Value Option When you select the Direct Q Value radio button, the Heat Transfer group appears. It consists of three objects, which are described in the table below. Formula Option When you select the Formula radio button, you instruct HYSYS to rigorously calculate the duty of each PFR subvolume using local heat transfer coefficients for the inside and the outside of each PFR tube using Equation (8.35) and Equation (8.36). Figure 8.63 Object Description Energy Stream The name of the duty stream. Duty The duty value to be specified in the energy stream. Heating \ Cooling Selecting one of these radio buttons does not affect the sign of the duty stream. Rather, if the energy stream is Heating, then the duty is added to the feed. If Cooling is chosen, the duty is subtracted. Figure 8.648-83 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-84 Plug Flow Reactor (PFR) Property ww Thwhere: Qj = heat transfer for subvolume j Uj = overall heat transfer coefficient for subvolume j A = surface area of the PFR tube Tbulkj = bulk temperature of the fluid Toutj = temperature outside of the PFR tube (utility fluid) where: U = overall heat transfer coefficient hout = local heat transfer coefficient for the outside (utility fluid) hw = local heat transfer coefficient inside the PFR tube = heat transfer term for the tube wall (ignored in calculations) For the Formula option, you must have an energy stream attached to the PFR. You cannot use this option while operating adiabatically. Qj = UjA(Tbulkj - Toutj) (8.35) Resistance of the tube wall to heat transfer is neglected. (8.36) The final term in Equation (8.36), which represents the thickness of the tube divided by the thermal conductivity of the tube material, is deemed negligible and is ignored in the PFR calculations. 1 U --- 1 hout --------- 1 hw ----- xw km -----+ += xw km -----8-84 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-85 ww ThIn each subvolume, heat is being transferred radially between the PFR fluid and the utility fluid. The two groups available on the Heat Transfer page allow you to specify parameters which are used in the determination of the duty. Heat Medium Side Heat Transfer Infos Group In the Heat Medium Side Heat Transfer Infos group, you can modify the parameters which are used to calculate the duty (Qj) for the outside of each PFR subvolume. The table below describes the parameters. The equation used to determine the temperature of the utility Figure 8.65 If you specify a heat flow on the Energy Stream property view and select the Formula radio button on the Heat Transfer page, inconsistencies appear in the solution. You cannot specify a duty and have HYSYS calculate the same duty. Parameter Formula Variable Input Required Wall Heat Transfer Coefficient hout Specify a value for the local heat transfer coefficient. Since the UA value, in this case the U being the local heat transfer coefficient, is constant, changes made to the specified length, diameter or number of tubes (on the Dimensions page) affects hout. Mole Flow m Molar flow of the energy stream utility fluid. Heat Capacity Cp Heat capacity of the energy stream utility fluid. Inlet Temperature T The temperature of the utility fluid entering the PFR. Calculated Duty Qj Duty calculated for each PFR subvolume.8-85 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-86 Plug Flow Reactor (PFR) Property ww Thfluid entering each subvolume j is: Tube Side Heat Transfer Info Group In the Tube Side Heat Transfer Info group, you can select the method for determining the inside local heat transfer coefficient (hw) by selecting one of the radio buttons and specifying the required parameters. The radio buttons are described in the table below. (8.37)Qj mCp Tj Tj 1+–( )= Radio Button Description View User Specify a value for the local heat transfer coefficient in the User Specified input field. Empirical Specify coefficients for the empirical equation which relates the heat transfer coefficient to the flowrate of the PFR fluid via the following equation: (8.38) You can also choose the basis for the equation as Molar, Mass or Volume. Standard Specify coefficients for the calculation of the Nusselt number, which is then used to calculate the local heat transfer coefficient: (8.39) (8.40) hw A FlowB×= Nu A ReB× PrC×= hw Nukg Dp -----------= HYSYS uses the following defaults: • A = 1.6 • B = 0.51 • C = 0.338-86 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-87 ww ThUser Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. 8.5.2 Reactions Tab You can add a reaction set to the PFR on the Reactions tab. Notice that only Kinetic, Heterogeneous Catalytic, and Simple Rate reactions are allowed in the PFR. The tab contains the following pages: • Overall • Details • Results Overall Page You can specify the reaction set and calculation information on For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.8-87 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-88 Plug Flow Reactor (PFR) Property ww Ththe Overall page. The Overall page consists of three groups: • Reaction Info • Integration Information • Catalyst Data Reaction Info Group In the Reaction Info group, you specify the following information: • The reaction set to be used. • The segment initialization method. Figure 8.66 Figure 8.678-88 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-89 ww ThFrom the Reaction Set drop-down list, select the reaction set you want to use for the PFR. As described earlier in this section, the PFR is split into segments by the reactor solver algorithm; HYSYS obtains a solution in each segment of the reactor. The segment reactions may be initialized using the following methods: Integration Information Group The Integration Information group consists of three fields: • Number of Segments • Minimum Step Fraction • Minimum Step Length The reaction set you want to use must be attached to the fluid package you are using in this environment. Initialization Option Description Current Initializes from the most recent solution of the current segment. Previous Initializes from the most recent solution of the previous segment. Re-init Re-initializes the current segment reaction calculations. Figure 8.688-89 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-90 Plug Flow Reactor (PFR) Property ww ThThe table below briefly describes the fields. During each segment calculation, HYSYS attempts to calculate a solution over the complete segment length. If a solution cannot be obtained, the current segment is halved, and HYSYS attempts to determine a solution over the first half of the segment. The segment continues to be halved until a solution is obtained, at which point the remaining portion of the segment is calculated. If the segment is divided to the point where its length is less than the minimum step length, calculations stop. Field Description Number of Segments The number of segments you want to split the PFR into. Minimum Step Fraction The minimum fraction an unresolved segment splits too. The length of each segment stays constant during the calculations. However, if a solution cannot be obtained for an individual segment, it is divided into smaller sections until a solution is reached. This does not affect the other segments. Minimum Step Length The product of the Reactor Length and the Minimum Step Fraction.8-90 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-91 ww ThCatalyst Data Group If you specified a void fraction less than one on the Rating tab, the Catalyst Data group appears. The following information must be specified: Figure 8.69 Field Description Particle Diameter The mean diameter of the catalyst particles. The default particle diameter is 0.001 m. Particle Sphericity This is defined as the surface area of a sphere having the same volume as the particle divided by the surface area of the particle. A perfectly spherical particle has a sphericity of 1.The Particle Diameter and Sphericity are used to calculate the pressure drop (in the Ergun pressure drop equation) if it is not specified. Solid Density The density of the solid portion of the particle, including the catalyst pore space (microparticle voidage).This is the mass of the particle divided by the overall volume of the particle, and therefore includes the pore space.The default is 2500 kg/m3. Bulk Density Equal to the solid density multiplied by one minus the void fraction. (8.41) where: = bulk density = solid density = macroparticle voidage (void fraction) Solid Heat Capacity Used to determine the solid enthalpy holdup in dynamics.The bulk density is also required in this calculation. ρb ρs 1 εma–( )= ρb ρs εma8-91 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-92 Plug Flow Reactor (PFR) Property ww ThDetails Page You can manipulate the reactions attached to the selected reactions set on the Details page. The Details page consists of three objects, which are briefly described in the table below. Stoichiometry Group When you select the Stoichiometry radio button, the Stoichiometry group appears. The Stoichiometry group allows you to examine the components involved in the currently selected reaction, their molecular weights as well as their stoichiometric coefficients. Figure 8.70 Object Description Reaction Allows you to select the reaction you want to use in the reactor. View Reaction Opens the Reaction property view for the selected reaction. This allows you to edit the reaction. Editing the Reaction propety view affects all other implementations of the selected reaction. Specifics Toggles between the Stoichiometry group or the Basis group (the groups are described in the following sections).8-92 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-93 ww Th The Balance Error (for the reaction stoichiometry) and the Reaction Heat (Heat of Reaction at 25°C) are also shown for the current reaction. Basis Group When you select the Basis radio button, the Basis group appears. In the Basis group, you can view the base component, and the rate expression parameters. You can make changes to these parameters, however these changes only affect the current implementation of the reaction and are not affected by other reactors using the reaction set or reaction. Figure 8.71 To affect change in the reaction over the entire simulation you must click the View Reaction button and make the changes in the Reaction property view. Figure 8.728-93 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-94 Plug Flow Reactor (PFR) Property ww ThView Reaction Button Click the View Reaction button to open the Reaction property view of the reaction currently selected in the Reaction drop- down list. Results Page The Results page displays the results of a converged reactor. The page consists of the Reaction Balance group which contains two radio buttons: • Reaction Extents • Reaction Balance The type of results displayed varies depending on the radio button selected. Any changes made to the Conversion Reaction property view are made globally to the selected reaction and any reaction sets which contain the reaction. You can change the specified conversion for a reaction directly on this page.8-94 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-95 ww ThReaction Extents When you select the Reaction Extents radio button, the Results page appears as shown in the figure below. The Reaction Balance group displays the following results for a converged reactor: Figure 8.73 Result Field Description Actual % Conversion Displays the percentage of the base component in the feed stream(s) which has been consumed in the reaction. Base Component The reactant to which the conversion is applied. Rxn Extent Lists the molar rate consumption of the base component in the reaction divided by its stoichiometirc coefficient appeared in the reaction.8-95 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-96 Plug Flow Reactor (PFR) Property ww ThReaction Balance When you select the Reaction Balance radio button, the option provides an overall component summary for the PFR. All components which appear in the connected component list are shown. Values appear after the solution of the reactor has converged. The Total Inflow rate, the Total Reacted rate and the Total Outflow rate for each component are provided on a molar basis. Negative values indicate the consumption of a reactant, while positive values indicate the appearance of a product. 8.5.3 Rating tab The Rating tab contains the following pages: • Sizing • Nozzles Figure 8.74 Any changes made to the global reaction affect all reaction sets to which the reaction is attached, provided local changes have not been made.8-96 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-97 ww ThSizing Page You can specify the tube dimensions and the tube packing information on the Sizing page. Tube Dimensions For the tube dimensions, you need to specify any three of the following four parameters: When three of these dimensions are specified, the fourth is automatically calculated. Notice that the Total Volume refers to the combined volumes of all tubes. By default, the number of tubes is set to 1. Although the number of tubes is generally specified, you can set this Figure 8.75 Tube Dimension Description Total Volume Total volume of the PFR. Length Total length of the individual tube. Diameter Diameter of an individual tube. Number of tubes. Total number of tubes required. This is always calculated to the nearest integer value.8-97 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-98 Plug Flow Reactor (PFR) Property ww Thparameter as a calculated value by selecting the Number of Tubes field and pressing the DELETE key. The number of tubes are always calculated as an integer value. It is possible to obtain a rounded value of 0 as the number of tubes, depending on what you specified for the tube dimensions. In this case, you have to re-specify the tube dimensions. The Tube Wall Thickness can also be specified. Tube Packing The Tube Packing group consists of two fields: • Void Fraction • Void Volume The Void Fraction is by default set to 1, in which case there is no catalyst present in the reactor. The resulting Void Volume is equal to the reactor volume. At Void Fractions less than 1, the Void Volume is the product of the Total Volume and Void Fraction. In this case, you are also required to provide information on the Overall page of the Reactions tab. This information is used to calculate pressure drop, reactor heat capacity and spatial velocity of the fluid travelling down the reactor. Nozzles Page The Nozzles page contains information regarding the elevation and diameter of the nozzles. The Void Volume is used to calculate the spatial velocity, which impacts the rate of reaction. Refer to Section 1.3.6 - Nozzles Page for more information.8-98 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-99 ww Th8.5.4 Work Sheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. 8.5.5 Performance Tab The Performance tab allows you to examine various axial profiles in the PFR. The tab contains the following pages, each page containing a general type of profile: • Conditions • Flows • Reaction Rates (Rxn Rates) • Transport • Compositions Each page consists of a table containing the relevant performance data and a Plot button which converts the data to a graphical form. The PF Specs page is relevant to dynamics cases only. Figure 8.76 Refer to Section 1.3.10 - Worksheet Tab for more information.8-99 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-100 Plug Flow Reactor (PFR) Property ww Th The data points are taken in the middle of each reactor segment, and correspond to the number of reactor segments you specified. Conditions Page The Conditions page allows you to view a table of the various physical parameters: Temperature, Pressure, Vapour Fraction, Duty, Enthalpy, Entropy, Inside HTC, and Outside HTC as a function of the Reactor Length. If you click the Plot button, a plot similar to the one shown in the figure below appears. It shows the selected Physical parameter as a function of the Reactor Length. The Reactor Length is always plotted on the x-axis. Figure 8.778-100 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-101 ww ThFlows Page There are four overall flow types which can be viewed in a table or plotted as a function of the Reactor Length: • Material Flow: Molar, Mass, or Volume • Energy: Heat If you click the Plot button, the table appears in a graphical form. Reaction Rates Page You can view either Reaction Rate or Component Production Rate data as a function of the Reactor Length on the Rxn Rates page. You can toggle between the two data sets by selecting the appropriate radio button. You can view the data in graphical form by clicking the Plot button. Transport Page The overall Transport properties appear in a tabular form as a function of the Reactor Length on the Transport page. Transport Properties: • Viscosity • Molar Weight • Mass Density • Heat Capacity • Surface Tension • Z Factor You can view the data in a graphical form by clicking the Plot button. Select the appropriate radio button to display the selected plot. Although only one reaction set can be attached to the PFR, it can contain multiple reactions.8-101 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-102 Plug Flow Reactor (PFR) Property ww ThCompositions Page You can view individual component profiles using one of six composition bases: • Molar Flow • Mass Flow • Liquid Volume Flow • Fraction: - Mole Fraction - Mass Fraction - Liquid Volume Fraction You can display the data in a plot form by clicking the Plot button. 8.5.6 Dynamics Tab The Dynamics tab contains the following pages: • Specs • Holdup • Duty • Stripchart If you are working exclusively in Steady State mode, you are not required to change any information on the pages accessible through the Dynamics tab.8-102 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-103 ww ThSpecs Page Dynamic Specifications Group The Dynamic Specifications group consists of eleven objects, which are described in the table below. Figure 8.78 Objects Description Initialize from Products radio button The composition of the holdup is calculated from a weighted average of all products exiting the holdup. A PT flash is performed to determine other holdup conditions. Initialize from First Feed radio button The composition of the holdup is calculated from the first feed entering the PFR reactor. Dry Startup radio button The calculations based on the holdup starts with no fluid in it. Steady State radio button Uses steady state results to initialize the holdup. Single Phase checkbox Allows you to specify a single phase reaction. Otherwise HYSYS considers it a vapour-liquid reaction. Laminar Flow checkbox Assumes laminar flow in the PFR.8-103 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-104 Plug Flow Reactor (PFR) Property ww ThPressure Flow Relation Group The Pressure Flow Relation group consists mainly of a table of the k values for each segment in the PFR. You can enter your own k values into this table or, while you are in Steady State mode, you can click the Calculate K’s button and HYSYS calculates the k values using the steady state data. Flow Equation checkbox Uses the flow equation to calculate the pressure gradient across the PFR. You are required to either estimate k values in steady state (by clicking the Calculate K’s button) or specifying your own values in the Pressure Flow Relation group. Fixed Delta P checkbox Assumes a constant pressure drop across the PFR. Does not require k values. PFR Elevation cell The height above ground that the PFR is currently positioned. Lag Rxn Temperature checkbox The option is designed to speed up the dynamic run for the reaction solver when the run has to invoke the steady state reaction solver. Mathematically, when you select the Lag Rxn Temperature checkbox, the reaction solver flashes with the explicit Euler method. Otherwise, for a dynamic run, the steady state reaction solver always flashes with the implicit Euler methods which could be slow with many iterations. The Lag Rxn Temperature may cause some instability due to the nature of the explicit Euler method. But it must compromise with the dynamic step size. Enable Explicit Reaction Calculation checkbox The Enable Explicit Reaction Calculations is defaulted to be used for dynamic run reaction solver. The explicit reaction solver is quick, but can introduce instability. You can deactivate this option. The implicit reaction solver is used instead. Objects Description8-104 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Reactor Operations 8-105 ww ThHoldup Page The Holdup page contains information regarding the properties, composition, and amount of the holdup in each phase in the PFR. The Holdup page consists of two groups: • Overall Holdup Details group displays the holdup data within the PFR operation. • Segment Holdup Details enables you to select and view individual holdup data of all the segments in the PFR operation. Figure 8.79 Refer to Section 1.3.3 - Holdup Page for more information.8-105 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 8-106 Plug Flow Reactor (PFR) Property ww ThDuty Page In the Source group, you can choose whether HYSYS calculates the duty applied to the vessel from a Direct Q or a Utility. If you select the Direct Q radio button, you can directly specify the duty applied to the holdup in the SP field. If you select the Utility radio button, you can specify the flow of the utility fluid. The duty is then calculated using the local overall heat transfer coefficient, the inlet fluid conditions, and the process conditions. The calculated duty is then displayed in the SP field or the Heat Flow field. If you select the Heating radio button, the duty shown in the SP field or Heat Flow field is added to the holdup. If you select the Cooling radio button, the duty is subtracted from the holdup. Stripchart Page The Stripchart page allows you to select and create default strip charts containing various variable associated to the operation. Figure 8.80 For more information regarding how the utility option calculates duty, refer to Chapter 5 - Logical Operations. Refer to Section 1.3.7 - Stripchart Page/Tab for more information.8-106 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-1 ww Th9 Rotating Operations9-1 9.1 Centrifugal Compressor or Expander.............................................. 2 9.1.1 Theory.................................................................................... 4 9.1.2 Compressor or Expander Property View..................................... 11 9.1.3 Design Tab ............................................................................ 12 9.1.4 Rating Tab............................................................................. 17 9.1.5 Worksheet Tab ....................................................................... 37 9.1.6 Performance Tab .................................................................... 37 9.1.7 Dynamics Tab ........................................................................ 38 9.2 Reciprocating Compressor ........................................................... 48 9.2.1 Theory.................................................................................. 49 9.2.2 Reciprocating Compressor Property View ................................... 55 9.2.3 Design Tab ............................................................................ 56 9.2.4 Rating Tab............................................................................. 61 9.2.5 Worksheet Tab ....................................................................... 62 9.2.6 Performance Tab .................................................................... 62 9.2.7 Dynamics Tab ........................................................................ 63 9.3 Pump ........................................................................................... 63 9.3.1 Theory.................................................................................. 64 9.3.2 Pump Property View ............................................................... 66 9.3.3 Design Tab ............................................................................ 68 9.3.4 Rating Tab............................................................................. 74 9.3.5 Worksheet Tab ....................................................................... 90 9.3.6 Performance Tab .................................................................... 90 9.3.7 Dynamics Tab ........................................................................ 91 9.4 References................................................................................... 95 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-2 Centrifugal Compressor or ww Th9.1 Centrifugal Compressor or Expander The Centrifugal Compressor operation is used to increase the pressure of an inlet gas stream with relative high capacities and low compression ratios. Depending on the information specified, the Centrifugal Compressor calculates either a stream property (pressure or temperature) or a compression efficiency. A Centrifugal Compressor can also be used to represent a Pump operation when a more rigorous pump calculation is required. The Pump operation in HYSYS assumes that the liquid is incompressible. Therefore, if you want to pump a fluid near its critical point (where it becomes compressible), you can do so by representing the Pump with a Centrifugal Compressor. The Centrifugal Compressor operation takes into account the compressibility of the liquid, thus performing a more rigorous calculation. The Expander operation is used to decrease the pressure of a high pressure inlet gas stream to produce an outlet stream with low pressure and high velocity. An expansion process involves converting the internal energy of the gas to kinetic energy and finally to shaft work. The Expander calculates either a stream property or an expansion efficiency. There are several methods for the Centrifugal Compressor or Expander to solve, depending on what information has been specified, and whether or not you are using the compressor’s characteristic curves. In general, the solution is a function of flow, pressure change, applied energy, and efficiency. The Centrifugal Compressor or Expander provides a great deal of flexibility with respect to what you can specify and what it then calculates. You must ensure that you do not enable too many of the solution options or inconsistencies may result.9-2 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-3 ww ThSome of the features in the dynamic Centrifugal Compressor and Expander operations include: • Dynamic modeling of friction loss and inertia in the Centrifugal Compressor or Expander. • Dynamic modeling which supports shutdown and startup behaviour. • Multiple head and efficiency curves. • Modeling of Stonewall and Surge conditions of the Centrifugal Compressor or Expander. • A dedicated surge controller which features quick opening capabilities. • Handling of phase changes that may occur in the unit operation (for example Expanders producing liquid). • Linking capabilities with other rotational equipment operating at the same speed with one total power. Typical Solution Methods The thermodynamic principles governing the Centrifugal Compressor and Expander operations are the same, but the direction of the energy stream flow is opposite. Compression requires energy, while expansion releases energy. The operating characteristics curves of a compressor is usually expressed as a set of polytropic head and efficiency curves made by manufacturers. Without Curves With Curves 1. Flow rate and inlet pressure are known. 2. Specify outlet pressure. 3. Specify either Adiabatic or Polytropic efficiency. 4. HYSYS calculates the required energy, outlet temperature, and other efficiency. 1. Flow rate and inlet pressure are known. 2. Specify operating speed. 3. HYSYS uses curves to determine efficiency and head. 4. HYSYS calculates outlet pressure, temperature, and applied duty. 1. Flow rate and inlet pressure are known. 2. Specify efficiency and duty. 3. HYSYS calculates outlet pressure, temperature, and other efficiency. 1. Flow rate, inlet pressure, and efficiency are known. 2. HYSYS interpolates curves to determine operating speed and head. 3. HYSYS calculates outlet pressure, temperature, and applied duty.9-3 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-4 Centrifugal Compressor or ww Th9.1.1 Theory Steady State For a Centrifugal Compressor, the isentropic efficiency is given as the ratio of the isentropic (ideal) power required for compression to the actual power required: For an Expander, the efficiency is given as the ratio of the actual power produced in the expansion process to the power produced for an isentropic expansion: For an adiabatic Centrifugal Compressor and Expander, HYSYS calculates the centrifugal compression (or expansion) rigorously by following the isentropic line from the inlet to outlet pressure. Using the enthalpy at that point, as well as the specified efficiency, HYSYS then determines the actual outlet enthalpy. From this value and the outlet pressure, the outlet temperature is determined. For a polytropic Centrifugal Compressor or Expander, the path of the fluid is neither adiabatic nor isothermal. For a 100% efficient process, there is only the condition of mechanical reversibility. For an irreversible process, the polytropic efficiency is less than 100%. Depending on whether the process is an expansion or compression, the work determined for the mechanically reversible process is multiplied or divided by an efficiency to (9.1) Throughout this chapter you will see “isentropic” and “adiabatic” used interchangeably. This is because they are the same. (9.2) Efficiency %( ) Power Requiredisentropic Power Requiredactual ----------------------------------------------------------------- 100%×= Efficiency %( ) Fluid Power Producedactual Fluid Power Producedisentropic ----------------------------------------------------------------------------------- 100%×=9-4 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-5 ww Thgive the actual work. The form of the polytropic efficiency equations are the same as Equation (9.1) and Equation (9.2). Notice that all intensive quantities are determined thermodynamically, using the specified Property Package. In general, the work for a mechanically reversible process can be determined from:. where: W = work V = volume dP = pressure difference As with any unit operation, the calculated information depends on the information which is specified by the user. In the case where the inlet and outlet pressures and temperatures of the gas are known, the ideal (isentropic) power of the Operation is calculated using one of the above equations, depending on the Centrifugal Compressor or Expander type. The actual power is equivalent to the heat flow (enthalpy) difference between the inlet and outlet streams. • For the Centrifugal Compressor: where the efficiency of the Centrifugal Compressor is then determined as the ratio of the isentropic power to the actual power required for compression. • For the Expander: The efficiency of the Expander is then determined as the ratio of the actual power produced by the gas to the isentropic power. (9.3) Power Requiredactual = Heat Flowoutlet - Heat Flowinlet (9.4) Power Producedactual = Heat Flowinlet - Heat Flowoutlet (9.5) W V Pd∫=9-5 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-6 Centrifugal Compressor or ww ThIn the case where the inlet pressure, the outlet pressure, the inlet temperature and the efficiency are known, the isentropic power is once again calculated using the appropriate equation. The actual power required by the Centrifugal Compressor (enthalpy difference between the inlet and outlet streams) is calculated by dividing the ideal power by the compressor efficiency. The outlet temperature is then rigorously determined from the outlet enthalpy of the gas using the enthalpy expression derived from the property method being used. For an isentropic compression or expansion (100% efficiency), the outlet temperature of the gas is always lower than the outlet temperature for a real compression or expansion. Dynamic An essential concept associated with the Centrifugal Compressor and Expander operations is the isentropic and polytropic power. The calculation of these parameters and other quantities are taken from “Compressors and Exhausters - Power Test Codes” from the American Society of Mechanical Engineers. The isentropic or polytropic power, W, can be calculated from: where: n = volume exponent CF = correction factor P1 =pressure of the inlet stream P2 = pressure of the exit stream = density of the inlet stream F1 =molar flow rate of the inlet stream MW = molecular weight of the gas (9.6)W F1 MW( ) n n 1– -----------⎝ ⎠ ⎛ ⎞CF P1 ρ1 -----⎝ ⎠ ⎛ ⎞ P2 P1 -----⎝ ⎠ ⎛ ⎞ n 1– n -----------⎝ ⎠ ⎛ ⎞ 1–×= ρ19-6 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-7 ww ThIsentropic power is calculated by defining the volume exponent as: where: = density of the exit stream corresponding to the inlet entropy Polytropic power is calculated by defining the volume exponent as: where: = density of the exit stream The correction factor is calculated as: where: = enthalpy of the exit stream corresponding to the inlet entropy h1 = enthalpy of the inlet stream An isentropic flash is performed to calculate the values of and . HYSYS calculates the compression (or expansion) rigorously by following the isentropic line from the inlet to the exit pressure. The path of a polytropic process is neither adiabatic nor isothermal. The only condition is that the polytropic process is reversible. (9.7) (9.8) (9.9) n P2 P1⁄( )ln ρ'2 ρ1⁄( )ln --------------------------= ρ′2 n P2 P1⁄( )ln ρ2 ρ1⁄( )ln --------------------------= ρ2 CF h'2 h1– n n 1– -----------⎝ ⎠ ⎛ ⎞ P2 ρ'2 ------ P1 ρ1 -----–⎝ ⎠ ⎛ ⎞ ------------------------------------------= h′2 h′2 ρ′29-7 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-8 Centrifugal Compressor or ww ThEquations Used The Centrifugal Compressor equations are used for the Centrifugal Compressor. The Expander equations are used for the Expander. Compressor Efficiencies The Adiabatic and Polytropic Efficiencies are included in the Centrifugal Compressor calculations. An isentropic flash (Pin and Entropyin) is performed internally to obtain the ideal (isentropic) properties. Expander Efficiencies For an Expander, the efficiencies are parts of the Expander calculations, and an isentropic flash is performed as well. The flash is done on the Expander fluid, and the results are not stored. Efficiencies Compressor Expander Adiabatic Polytropic where: where: Work Required ideal( ) Work Required actual( ) ---------------------------------------------------------- Hout Hin–( ) ideal( ) Hout Hin–( ) actual( ) -------------------------------------------------------= Work Produced actual( ) Work Produced ideal( ) ----------------------------------------------------------- Hout Hin–( ) actual( ) Hout Hin–( ) ideal( ) -------------------------------------------------------= Pout Pin ----------- ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ n 1– n -----------⎝ ⎠ ⎛ ⎞ 1– n n 1–( ) ----------------⎝ ⎠ ⎛ ⎞ k 1– k -----------⎝ ⎠ ⎛ ⎞×× Pout Pin ----------- ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ k 1– k -----------⎝ ⎠ ⎛ ⎞ 1– ----------------------------------------------------------------------------------------------------------- AdiabaticEff× n Pout Pin⁄( )log ρout actual, ρin⁄( )log ---------------------------------------------------------= k Pout Pin⁄( )log ρout ideal, ρin⁄( )log ------------------------------------------------------= Pout Pin ----------- ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ k 1– k -----------⎝ ⎠ ⎛ ⎞ 1– Pout Pin ----------- ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ n 1– n -----------⎝ ⎠ ⎛ ⎞ 1– n n 1–( ) ----------------⎝ ⎠ ⎛ ⎞ k 1– k -----------⎝ ⎠ ⎛ ⎞×× ----------------------------------------------------------------------------------------------------------- AdiabaticEff× n Pout Pin⁄( )log ρout actual, ρin⁄( )log ---------------------------------------------------------= k Pout Pin⁄( )log ρout ideal, ρin⁄( )log ------------------------------------------------------=9-8 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-9 ww ThCompressor Heads The Adiabatic and Polytropic Heads are performed after the Centrifugal Compressor calculations are completed, only when the Results page of the Centrifugal Compressor is selected. The Work Required (actual) is the compressor energy stream (heat flow). The Polytropic Head is calculated based on the ASME method (“The Polytropic Analysis of Centrifugal Compressors”, Journal of Engineering for Power, J.M. Schultz, January 1962, p. 69-82). where: H = mass enthalpy out = product discharge in = feed stream P = pressure = mass density n = polytropic exponent k = isentropic exponent Efficiencies Compressor Expander ρ 9-9 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-10 Centrifugal Compressor or ww ThExpander Heads The Adiabatic and Polytropic Heads are performed after the Expander calculations are completed, only when the Results page of the Expander is selected. The Work Produced (actual) is the Expander energy stream (heat flow). Head Compressor Expander Adiabatic Polytropic where: where: where: H = mass enthalpy out = product discharge in = feed stream P = pressure = mass density f = polytropic head factor n = polytropic exponent k = isentropic exponent Work Required actual( ) MassFlowRate ---------------------------------------------------------- AdiabaticEff 1 g gc⁄( ) -----------------×× Work Produced actual( ) MassFlowRate ----------------------------------------------------------- 1 AdiabaticEff ---------------------------------- 1 g gc⁄( ) -----------------×× f n n 1– -----------⎝ ⎠ ⎛ ⎞ Pout ρout actual, ------------------------------ ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ Pin ρin -------- ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ –×× 1 g gc⁄( ) -----------------× f Hout ideal, Hin– k k 1– -----------⎝ ⎠ ⎛ ⎞ Pout ρout ideal, --------------------------- ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ Pin ρin -------- ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ –× ----------------------------------------------------------------------------------= n Pout Pin⁄( )log ρout actual, ρin⁄( )log ---------------------------------------------------------= k Pout Pin⁄( )log ρout ideal, ρin⁄( )log ------------------------------------------------------= f n n 1– -----------⎝ ⎠ ⎛ ⎞ Pout ρout actual, ------------------------------ ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ Pin ρin -------- ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ –××– 1 g gc⁄( ) -----------------× f Hout ideal, Hin– k k 1– -----------⎝ ⎠ ⎛ ⎞ Pout ρout ideal, --------------------------- ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ Pin ρin -------- ⎝ ⎠ ⎜ ⎟ ⎛ ⎞ –× ----------------------------------------------------------------------------------= n Pout Pin⁄( )log ρout actual, ρin⁄( )log ---------------------------------------------------------= k Pout Pin⁄( )log ρout ideal, ρin⁄( )log ------------------------------------------------------= ρ 9-10 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-11 ww Th9.1.2 Compressor or Expander Property View There are two ways that you can add a Compressor or Expander to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Rotating Equipment radio button. 3. From the list of available unit operations, select Compressor or Expander. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the Compressor icon or Expander icon. The Compressor or Expander property view appears. Figure 9.1 Compressor icon Expander icon9-11 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-12 Centrifugal Compressor or ww Th9.1.3 Design Tab The Design tab contains the following pages: • Connections • Parameters • Links • User Variables • Notes Connections Page The figure below shows the Connections page for the Centrifugal Compressor property view. The Connections page allows you to specify the name of the operation, as well as the inlet stream, outlet stream, and energy stream. Figure 9.2 The information required on the Connections page of the Expander is identical; the only difference is that the Expander icon is shown rather than the Compressor icon.9-12 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-13 ww ThParameters Page You can specify the duty of the attached energy stream on the Parameters page, or allow HYSYS to calculate it. The adiabatic and polytropic efficiencies appear on this page as well. The Parameters page for the Compressor and the Expander are similar. However, the following items are not available for the Expander: • Operating Mode group • Multiple MW Curves in the Curve Input Option group In the Operating Mode group, you can switch between a Centrifugal and Reciprocating Compressor by selecting the corresponding radio button. If you choose the Centrifugal radio button, the radio buttons in the Curve Input Option group are enabled. Figure 9.3 You can specify only one efficiency, either adiabatic or polytropic. If you specify one efficiency and a solution is obtained, HYSYS back calculates the other efficiency, using the calculated duty and stream conditions.9-13 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-14 Centrifugal Compressor or ww ThIn the Curve Input Option group the following radio buttons are available: • Select the Single Curve radio button to model your compressor with a single pair of head vs. flow and efficiency vs. flow curves. • Select the Multiple MW Curves radio button if you have a set of curves that describe the compressor performance as a function of the flowing gas molecular weight (MW). • Select the Multiple IGV Curves radio button if you have a set of curves that describe the compressor performance as a function of inlet guide vane (IGV) position. Links Page Compressors and expanders modeled in HYSYS can have shafts that are physically connected to the unit operation. Linking compressors and expanders in HYSYS means the: • Speed of each linked unit operation is the same. • Sum of the duties of each linked Compressor or Expander and the total power loss equals zero. The Single Curve radio button still allows multiple curves as a function of speed, but not MW or IGV position. When you select Multiple IGV Curves radio button, the current inlet guide vane position is specified during the operation of the compressor. The rotational linker operates both in Steady State and Dynamic mode. It is not significant which order the Compressors or Expanders are linked. The notion of upstream and downstream links is arbitrary and determined by the user.9-14 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-15 ww ThA list of available compressors or expanders can be displayed by clicking the down arrow in the Downstream Link field. In most cases, one additional specification for any of the linked operations is required to allow the simulation case to completely solve. Ideally, you should specify one of the following for any of the linked unit operations. • Duty • Speed • Total Power Loss It is also possible to link an Expander to a Compressor, and use the Expander to generate kinetic energy to drive the Compressor. If this option is chosen, the total power loss is typically specified as zero. Figure 9.4 The Gear Ratio field displays the ratio of the speed from the next linked operation divided by the speed of the current pump. Select the Dynamic Specification checkbox to specify the total power loss (or power gain by entering a negative value) for the linked operation. You can ignore this option in Steady State mode.9-15 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-16 Centrifugal Compressor or ww ThDynamics Mode In Dynamics mode, at least one curve must be specified in the Curves page of the Rating tab for each linked unit operation. Ideally, a set of linked compressor or expanders should only have the Use Characteristic Curves checkbox selected in the Specs page of the Dynamics tab. In addition, the total power loss for the linked operations should be specified. Usually, total power input to the linked compressors or expanders is calculated in a Spreadsheet operation and specified by you in the Total Power Loss field. If you want to provide the total power input to a set of linked compressors or expanders, the total power input to the linked operations is defined in terms of a total power loss. The relationship is as follows: User Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. (9.10)Total Power Input - Total Power Loss= For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.9-16 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-17 ww Th9.1.4 Rating Tab The Rating tab contains following pages: • Curves • Flow Limits • Nozzles • Inertia Curves Page One or more Centrifugal Compressor or Expander curves can be specified on the Curves page. You can create adiabatic or polytropic plots for values of efficiency and head. The efficiency and head for a specified speed can be plotted against the capacity of the Centrifugal Compressor or Expander. Multiple curves can be plotted to show the dependence of efficiency and head on the speed of Centrifugal Compressors or Expanders. The Nozzles page is only visible if you have the HYSYS Dynamics license. Figure 9.59-17 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-18 Centrifugal Compressor or ww ThIf you do not use curves, specify four of the following variables; HYSYS will calculate the fifth variable and the duty: • Inlet Temperature • Inlet Pressure • Outlet Temperature • Outlet Pressure • Efficiency It is assumed that you have specified the composition and flow. Single MW (Molecular Weight) If you choose the Single Curve radio button on the Parameters page of the Design Tab, the only group visible on the Curves page is the Compressor Curves group. Figure 9.6 This option is only relevant for compressors and not expanders.9-18 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-19 ww ThEntering Curve Data The following are steps to add a curve to the compressor or expander: 1. Select either the Adiabatic or Polytropic radio button in the Efficiency group. This determines the basis of your input efficiency values. The efficiency type must be the same for all input curves. 2. Click the Add Curve button and the Curve property view appears. 3. You can specify the following data in the Curve property view. 4. Click the Close icon to return to the Curves page. 5. Select the corresponding Activate checkbox to use that curve in calculations. Figure 9.7 Curve Data Description Name Name of the curve. Speed The rotational speed of the Centrifugal Compressor or Expander. This is optional if you specify only one curve. HYSYS can interpolate values for the efficiency and head of the Centrifugal Compressor or Expander for speeds that are not plotted. Flow Units/Head Units Units for the flow and head. Flow/Head/% Efficiency One row of data is equivalent to one point on the curve. For better results, you should enter data for at least three (or more) points on the curve.9-19 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-20 Centrifugal Compressor or ww Th6. For each additional curve, repeat steps #2 to #5. 7. Click the Enable Curves checkbox. You can remove a specific curve from the calculation by clearing its Activate checkbox. HYSYS uses the curve(s) to determine the appropriate efficiency for your operational conditions. If you specify curves, ensure the efficiency values on the Parameters page are empty or a consistency error will be generated. Once a curve has been created, the following four buttons on the Curves page are enabled: • View Curve. Allows you to view or edit your input data in the Curve property view. • Delete Curve. Allows you to delete the selected curve from the simulation. • Clone Curve. Allows you to duplicate an existing curve. • Plot Curves. Allows you to view a graph of activated curves. You can access the Curve property view of an existing curve by clicking the View Curve button or by double-clicking the curve name. Deleting Curve Data The following are two ways you can delete information within a curve: 1. Double-click the curve name to open the Curve property view. 2. Highlight the data you want to delete and click the Erase Selected button. OR 1. Select the curve within the table and click the View Curve button. 2. Click the Erase All button to delete all of the information within the Curve property view.9-20 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-21 ww ThSingle Curve When you have a single curve, the following combinations of input allow the operation to completely solve (assuming the feed composition and temperature are known): • Inlet Pressure and Flow Rate • Inlet Pressure and Duty • Inlet Pressure and Outlet Pressure • Inlet Pressure and Efficiency corresponding to the Curve type (for example, if the Curve is Adiabatic you need to provide an Adiabatic Efficiency). Multiple Curves If multiple curves have been installed, an operating speed is specified on the Curves page, and one of the multiple curves’ speed equals the operating speed, then only the curve with the corresponding speed is used. For example, if you provide curves for two speeds (1000/min and 2000/min), and you specify an operating speed of 1000/min, then only the curve with the speed of 1000/min is used within the calculation. If multiple curves have been installed, an operating speed has been specified, and none of the multiple curves’ speed equals the operating speed, then all of the curves will be used within the calculation. For example, if you provide curves for two speeds (1000/min and 2000/min), and you specify an operating speed of 1500/min, HYSYS interpolates between the two curves to obtain the solution. Conversely, if you specify an operating speed outside the range of speeds provided by the curves, HYSYS uses an extrapolation method to obtain the solution. Currently, HYSYS supports both Linear and Quadratic extrapolation methods and the user has the option to pick which method to use for extrapolation. Linear extrapolation method is set as the default option and is highly encouraged since extrapolation in general will yield unpredictable results, especially when one does not know the actual form of the data. If multiple curves are used, you need to provide: • Feed Composition • Pressure9-21 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-22 Centrifugal Compressor or ww Th• Temperature • Inlet Flow Rate • Only one of the following variables: - Duty - Outlet Pressure - Operating Speed HYSYS then calculates the other two variables. Dynamics Mode In order to run a stable and realistic dynamics model, HYSYS requires you to input reasonable curves. If compressors or expanders are linked, it is a good idea to ensure that the curves plotted for each unit operation span a common speed and capacity range. Typical Compressor and Expander curves are plotted in Figure 9.8 and Figure 9.9. Figure 9.89-22 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-23 ww ThFor an Expander, the head is only zero when the speed and capacity are zero. Multiple MW (Molecular Weight) The Multiple MW (molecular weight) option is for more advanced users of HYSYS. This option allows the performance of the compressor to vary with the flowing gas molecular weight based upon the performance map you specified. When you choose the Multiple MW Curves radio button on the Parameters page of the Design tab, the MW Curve Collections group and the Plot All Collections checkbox are added to the Curves page. Figure 9.9 This option is only relevant for compressors and not expanders.9-23 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-24 Centrifugal Compressor or ww ThThe following is a brief description of the fields and buttons found within the MW Curve Collections group. Figure 9.10 Fields Description MW Curve Collections list Displays the list of curve collection available in the unit operation. Each curve collection contains a set of data curves at a particular molecular weight. Curve Collection name Allows you to rename the selected curve collection in the list. Design MW The Design MW is the design average molecular weight for the compressor. Its default value is the same as the value for the Actual MW. This value is only used as a reference point and does not affect the Compressor calculation. The Plot All Collections checkbox is useful if you want to see all the curves for all the curve collection (in the compressor) appear in one plot. This is particularly useful if all the curves data is based on one speed.9-24 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-25 ww ThCreating Multiple Curve Collections The following are methods on how you can create multiple curve collections: 1. Enter the data for the curve(s). All of these values will be stored under a curve collection named CurveCollection-1. 2. Click the Set Simple Curves button. 3. Two hypothetical curve collections will appear (named CurveCollection-2 and CurveCollection-3). These two new collections will provide you with rough data for curves generated with lighter or heavier components. These estimated values are based on the values entered for CurveCollection-1. Curve MW Each curve collection has its corresponding set of curves at a particular molecular weight. Actual MW This value is calculated by HYSYS. The field displays the actual MW of the stream within your case. The following are descriptions of three potential operating situations: • If the Actual MW is the same as the Design MW, it means the compressor is operating with components at your designed MW. • If the Actual MW is less than the Design MW value, it means the compressor is operating with lighter components. • If the Actual MW is more than the Design MW value, it means the compressor is operating with heavier components. Buttons Description Add Curve Collection Adds another empty curve collection to the MW Curve Collections list. Del. Curve Collection Deletes the selected curve collection in the MW Curve Collections list. Set Simple Curves Creates two more curve collections with curve data based on the selected curve collection in the MW Curve Collections list. The data values within the two new curve collections are estimated values for testing purposes only. You should modify this data accordingly to specify your actual curve values. Fields Description Refer to Entering Curve Data section for more information.9-25 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-26 Centrifugal Compressor or ww ThOR 1. Enter the data for the curve(s). All of these values will be stored under a curve collection. 2. Click the Add Curve Collection button. 3. Repeat step #1 to enter the data for the new curve collection. 4. Repeat steps #2 to #3 for each additional curve collection. Multiple IGV (Inlet Guide Vane) The Multiple IGV (inlet guide vane) Curves option allows you to model a compressor with adjustable guide vanes. The guide vanes are modulated to control the capacity of the compressor. When you choose the Multiple IGV Curves radio button on the Parameters page of the Design tab, the IGV Curve Collections group and the Plot All Collections checkbox are added to the Curves page. The values given in CurveCollection-2 and CurveCollection-3 are for testing purposes only. You need to modify the data accordingly in order to determine the definite curve values. To use the Multiple IGV Curves feature, you need a manufacturers performance map of curves at different IGV operating conditions. Refer to Entering Curve Data section for more information.9-26 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-27 ww ThThe following is a brief description of the fields and buttons found within the IGV Curve Collections group. Figure 9.11 Fields Description IGV Curve Collections list Displays the list of curve collection available in the unit operation. Each curve collection contains a set of data curves at a particular inlet guide vane. Curve Collection name Allows you to rename the selected curve collection in the list. Curve IGV Allows you to specify the inlet guide vane position that the entered curve set data is at (or for). Current IGV Allows you to specify the current position that the compressor is operating at. You can specify this value to different values during operation or specify this value in controllers during Dynamics mode. Buttons Description Add Curve Collection Adds another empty curve collection to the IGV Curve Collections list. The Plot All Collections checkbox is useful if you want to see all the curves for all the curve collection (in the compressor) appear in one plot. This feature is particularly useful if all the curves data is based on one speed.9-27 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-28 Centrifugal Compressor or ww ThCreating Multiple Curve Collections The following are methods on how you can create multiple curve collections: 1. Enter the data for the curve(s). All of these values will be stored under a curve collection named CurveCollection-1. 2. Click the Set Simple Curves button. 3. Two hypothetical curve collections will appear (named CurveCollection-2 and CurveCollection-3). These two new collections will provide you with rough data for curves generated with lighter or heavier components. These estimated values are based on the values entered for CurveCollection-1. OR 1. Enter the data for the curve(s). All of these values will be stored under a curve collection. 2. Click the Add Curve Collection button. 3. Repeat step #1 to enter the data for the new curve collection. 4. Repeat steps #2 to #3 for each additional curve collection. Del. Curve Collection Deletes the selected curve collection in the IGV Curve Collections list. Set Simple Curves Creates two more curve collections with curve data based on the curve collection in the IGV Curve Collections list. The data values within the two new curve collections are estimated values for testing purposes only. You should modify this data accordingly to specify your actual curve values. The values given in CurveCollection-2 and CurveCollection-3 are for testing purposes only. You need to modify the data accordingly in order to determine the definite curve values. Buttons Description Refer to Entering Curve Data section for more information. Refer to Entering Curve Data section for more information.9-28 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-29 ww ThFlow Limits Page There is a certain range that the dynamic Centrifugal Compressors or Expanders can operate in depending on its operating speed. The lower flow limit of a Centrifugal Compressor is called the surge limit, whereas the upper flow limit is called the stonewall limit. In HYSYS, you can specify the flow limits of a Centrifugal Compressor or Expander by plotting surge and stonewall curves. From the Flow Limits page, it is possible to add Surge or Stonewall curves for the Centrifugal Compressor. When a dynamic Centrifugal Compressor reaches its stonewall limit, HYSYS fixes the flow at that Centrifugal Compressor speed. When a Centrifugal Compressor reaches the surge limit, the flow reverses and cycles continuously causing damage to Figure 9.12 If you are working exclusively in Steady State mode, you are not required to change any information on the Flow Limits page. The procedure for adding or editing a Stonewall curve is similar to the procedure for adding or editing a Surge curve.9-29 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-30 Centrifugal Compressor or ww Ththe Centrifugal Compressor. This phenomenon is modeled in HYSYS by causing the flow rate through the Centrifugal Compressor to fluctuate randomly below the surge flow. Adding or Editing a Surge Curve To add or edit a Surge curve, follow this procedure: 1. Click the Surge Curve button. The Surge flow curve property view appears. 2. From the Speed Units drop-down list, select the units you want to use for the speed measurements. 3. From the Flow Units drop-down list, select the units you want to use for the flow measurements. 4. Specify the speed and flow data points for the curve. 5. Once you have entered all the data points, click the Close icon to return to the Compressor or Expander property view. 6. Select the Use Surge Curve checkbox to use the surge curve for the compressor or expander calculations. Figure 9.139-30 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-31 ww ThDeleting data of a Surge Curve To delete data within a surge curve, do the following: 1. Click the Surge Curve button. The Surge flow curve property view appears. 2. Do one of the following: • To remove a certain data point, select either the speed cell or flow cell, and click the Erase Selected button. • To remove all the data points, click the Erase All button. Nozzles Page The Nozzles page contains information regarding the elevation and diameter of the nozzles. For a Centrifugal Compressor or Expander unit operation it is strongly recommended that the elevation of the inlet and exit nozzles are equal. If you want to model static head, the entire piece of equipment can be moved by modifying the Base Elevation relative to Ground Elevation field. Inertia Page The inertia modeling parameters and the friction loss associated with the impeller in the Centrifugal Compressor can be specified on the Inertia page. If you are working exclusively in Steady State mode, you are not required to change any information on the Nozzles page. If you are working exclusively in Steady State mode, you are not required to change any information on the Inertia page. The HYSYS Dynamics license is required to use the Inertia features found on this page. Refer to Section 1.3.6 - Nozzles Page for more information. Refer to Section 1.6.4 - Inertia in the HYSYS Dynamic Modeling guide for more information.9-31 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-32 Centrifugal Compressor or ww ThElectric Motor Page The Electric Motor page allows you to drive your rotating unit operation through the designation of a motor torque versus speed curve. These torque vs. speed curves can either be obtained from the manufacturer for the electric motor being used or from a typical curve for the motor type. For most process industry applications, a NEMA type A or B electric motor is used. When you use the Electric Motor option the torque (and power) generated by the motor is balanced against the torque consumed by the rotating equipment. When you activate the Electric Motor option: • An On checkbox will appear at the bottom of the Compressor property view, which can be used to turn the motor on and off. • The Compressor operation icon in the PFD changes to include a motor. The Electric Motor functionality is only relevant in Dynamics mode. The Electric Motor option uses one degree of freedom in your dynamic specifications. The results of the Electric Motor option are presented on the Power Page in the Performance Tab of the rotating equipment operation. Figure 9.149-32 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-33 ww ThThe following table lists and describes the objects in the Electric Motor page: Object Description Synchronous Speed cell Allows you to specify the synchronous speed of the motor. Full Load Speed cell Allows you to specify the design speed of the motor. Full Load Torque cell Allows you to specify the design torque of the motor. Full Load Power cell Allows you to specify the design power of the motor. Gear Ratio cell Allows you to manipulate the gear ratio. The gear ratio is the rotating equipment’s speed divided by the motor speed. Motor Inertia cell Allows you to specify the motor inertia. Motor Friction Factor cell Allows you to specify the motor friction factor. User Electric Motor checkbox Allows you to toggle between using or ignoring the electric motor functionality. Speed vs Torque Curve button Allows you to view the plot and specify the data in the Speed vs. Torque Curve Property View. Size Inertia button Allows you to calculate the inertia based on the following equation3: where: I = inertia ( ) P = full load power of the motor (kW) N = full load speed of the motor (rpm/1000) Simple radio button Allows you to select the Simple model for the modelling option. Breakdown radio button Allows you to select the Breakdown model for the modelling option. Electric Brake checkbox Allows you to model the torque force on the rotating equipment simply by changing the sign of the produced torque value. Gearing checkbox Allows the gear ratio to be updated during integration. A zero value for the gear ratio indicates a decoupling of the equipment. I 0.0043 P N ---⎝ ⎠ ⎛ ⎞ 1.48 = kg m3⋅ Refer to Operation Model section for more information.9-33 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-34 Centrifugal Compressor or ww ThTheory The definition of torque is found from the following equation: where: P = power consumption (kW) T = torque (Nm) = synchronous speed (rpm) The synchronous electric motor speed can be found from: where: f = power supply frequency (Hz), typically either of 50 or 60 p = number of poles on the stator The number of poles is always an even number of 2, 4, 6, 8, 10, and so forth. In North America, common motor speeds are always 3600, 1800, 1200, 900, 720, and so forth. The relationships of inertia and friction loss in the total energy balance are the same as for the pump and compressor operations. Operation Model There are three ways to use the Electric Motor curve, each with progressing rigor. • Simple Model. The easiest calculation is the Simple modelling option (default). This model is useful if you just want to model the startup/shutdown transient and want to keep the equipment at the fixed full load speed once operating. In this mode, once the speed has accelerated enough to become larger than the last (9.11) (9.12) P T ω 2 π××× 1000 60× --------------------------------= ω ω 120f p ----------=9-34 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-35 ww Th(largest) curve speed value entered, the motor speed immediately is set to the full load speed and remains there until the motor is turned off. If the process invokes a larger torque than the motor curve suggests the motor can produce, the speed still remains synchronous and remains at its full load value. • Breakdown Model. The Breakdown modelling option allows the speed to reduce if the system torque or resistance gets too large. To use this option, the largest (last) curve speed value entered should be just less than the full load speed value. This provides for a smooth transition in operation. You can drop the curve to a lower torque than the breakdown torque if desired. • Simple Model Modified. The third modelling approach is to use the Simple model option, but enter the speed vs torque curve up to a speed value of 99.99% of the synchronous speed. In this case the full load speed entered is only used, if necessary, to calculate the full load torque and is not used otherwise. With this approach, the speed vs torque curve must ascend or drop from the breakdown torque to approach zero torque at 100% speed. For most motor types, this approach is nearly vertical (asymptotic). This modelling approach allows for the simulation of the slippage of the motor speed based upon the actual and current system resistance. The operating speed of the motor will then move based upon the process model operation. Use a near vertical curve to keep a constant speed or level it off more to allow greater slip. This performance should be predicted by using an accurate manufacturers torque vs speed curve. The speed and torque are not solved simultaneously with the pressure flow solution but instead is lagged by a time step. You may need to use a smaller time step to ensure accuracy and pressure flow solver convergence.9-35 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-36 Centrifugal Compressor or ww ThSpeed vs. Torque Curve Property View The Speed vs. Torque Curve property view displays the data curve of speed versus torque in both table and plot format. To access the Speed vs. Torque Curve property view, click the Speed vs Torque Curve button on the Electric Motor page of the Rating tab. The following table lists and describes the objects available in the Speed vs. Torque Curve property view: Figure 9.15 The values under the Speed and Torque columns are entered as a percent of the Full Load values. The Speed vs. Torque curve must always contain a 0% speed value. The maximum table speed cannot be greater than the value in the Maximum X value field. The Maximum X value is the ratio of the full load speed to the synchronous speed. During integration, the current operating point appears on the Torque vs. Speed curve. Object Description Maximum X value display field Displays the ratio of the full load speed to the synchronous speed. Speed column Allows you to specify speed percentage values you want to plot.9-36 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-37 ww Th9.1.5 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the Centrifugal Compressor or Expander. 9.1.6 Performance Tab The Performance page contains the calculated results of the compressor or expander. Results Page On the Results page, you can view a table of calculated values for the Centrifugal Compressor or Expander: Torque column Allows you to specify the torque percentage values associated with the speed. Erase Selected button Allows you to delete the row containing both speed and torque percentage values of the selected cell. Erase All button Allows you to delete all the values in the table. The PF Specs page is relevant to dynamics cases only. • Adiabatic Head • Polytropic Head • Adiabatic Fluid Head • Polytropic Fluid Head • Adiabatic Efficiency • Polytropic Efficiency • Power Produced • Power Consumed • Friction Loss • Rotational inertia • Fluid Power • Polytropic Head Factor • Polytropic Exponent • Isentropic Exponent • Speed Object Description Refer to Section 1.3.10 - Worksheet Tab for more information.9-37 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-38 Centrifugal Compressor or ww ThPower Page The Power page is only available for the compressor. The information displayed in this page is: • Compressor rotor power • Compressor rotor torque • Electric motor power • Electric motor torque • Electric motor speed 9.1.7 Dynamics Tab The Dynamics tab contains the following pages: • Specs • Holdup • Stripchart Specs Page The dynamic specifications of the Centrifugal Compressor or Expander can be specified on the Specs page. If you are working exclusively in Steady State mode, you are not required to change any information on the pages accessible through this tab. Figure 9.169-38 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-39 ww ThIn general, two specifications are required in the Dynamics Specifications group. You should be aware of specifications which may cause complications or singularity in the pressure flow matrix. Some examples of such cases are: • The Pressure Increase checkbox should not be selected if the inlet and exit stream pressures are specified. • The Speed checkbox should not be selected if the Use Characteristic Curves checkbox is not selected. The possible dynamic specifications are as follows: Duty The duty is defined, in the case of the Centrifugal Compressor operation, as the power required to rotate the shaft and provide energy to the fluid. The duty has three components: The duty in a Centrifugal Compressor should be specified only if there is a fixed power available to be used to drive the shaft. Efficiency (Adiabatic and Polytropic) For a dynamic Centrifugal Compressor, the efficiency is given as the ratio of the isentropic power required for compression to the actual energy imparted to the fluid. The efficiency, , is defined as: where: W = isentropic power F1 = molar flow rate of the inlet gas stream Duty = Power imparted to the fluid + Power required to change the rotational speed of the shaft + Power lost due to mechanical friction loss (9.13) (9.14) η η W to system( ) F1 MW( ) h2 h1–( ) -----------------------------------------=9-39 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-40 Centrifugal Compressor or ww ThMW = molecular weight of the gas h1 = inlet head h2 = outlet head For a dynamic Expander, the efficiency, , is defined as: If a polytropic efficiency definition is required, the polytropic work should be provided in Equation (9.14) or Equation (9.15). If an adiabatic efficiency definition is required, the isentropic work should be provided. The general definition of the efficiency does not include the losses due to the rotational acceleration of the shaft and seal losses. Therefore, the efficiency equations in dynamics are not different from the general efficiency equations defined in Section 9.1.1 - Theory. This is true since the actual work required by a steady state Centrifugal Compressor is the same as the energy imparted to the fluid. If the Centrifugal Compressor or Expander curves are specified in the Curves page of the Rating tab, the adiabatic or polytropic efficiency can be interpolated from the flow of gas and the speed of the Centrifugal Compressor or Expander. Pressure Increase A Pressure Increase specification can be selected if the pressure drop across the Centrifugal Compressor is constant. (9.15) η η F1 MW( ) h1 h2–( ) W from system( ) -----------------------------------------=9-40 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-41 ww ThHead The isentropic or polytropic head, h, can be defined as a function of the isentropic or polytropic work. The relationship is: where: W = isentropic or polytropic power MW = molecular weight of the gas CF = correction factor (For a compressor, this factor is the inverse value of the adiabatic/polytropic efficiency; for an expander, it is the adiabatic/polytropic efficiency.) F1 = molar flow rate of the inlet gas stream g = gravity acceleration If the Centrifugal Compressor or Expander curves are provided in the Curves page of the Rating tab, the isentropic or polytropic head can be interpolated from the flow of gas and the speed of the Centrifugal Compressor or Expander. Fluid Head The Fluid Head is the produced head in units of energy per unit mass. Capacity The capacity is defined as the actual volumetric flow rate entering the Centrifugal Compressor or Expander. A capacity specification can be selected if the volumetric flow to the unit operation is constant. (9.16)W MW( )F1 CF( )gh=9-41 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-42 Centrifugal Compressor or ww ThSpeed The rotational speed of the shaft, , driving the Centrifugal Compressor or being driven by the Expander can be specified. Shift to Reciprocating Compressor (Positive Displacement) Select the Reciprocating (Positive Displacement) checkbox if you want to change the Centrifugal Compressor to a Reciprocating Compressor. You can change the Centrifugal Compressor to a Reciprocating Compressor at any time. The reciprocating checkbox option is only available with the compressor unit operation. Use Characteristic Curves Select the Use Characteristic Curves checkbox, if you want to use the curve(s) specified in the Curves page of the Rating tab. If a single curve is specified in a dynamics Centrifugal Compressor, the speed of the Centrifugal Compressor is not automatically set to the speed of the curve (unlike the steady state Centrifugal Compressor or Expander unit operation). A different speed can be specified and HYSYS extrapolates values for head and efficiency. Linker Power Loss To specify the power loss (negative for a power gain) of the linked operations, select the Linker Power Loss checkbox. Electric Motor Select the Electric Motor checkbox if you want to use the electric motor functionality. ω Refer to Section 9.2 - Reciprocating Compressor for more information.9-42 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-43 ww ThSurge Controller The Create Surge Controller button on the Specs page of the Dynamics tab opens a Surge Controller property view (which is owned by the Centrifugal Compressor). If you decide to delete the Centrifugal Compressor, the surge controller associated with the Centrifugal Compressor is deleted as well. The surge controller also works exclusively with Centrifugal Compressor and Expander unit operations. As mentioned, a Centrifugal Compressor surges if its capacity falls below the surge limit. The surge controller determines a minimum volumetric flow rate that the Centrifugal Compressor should operate at without surging. This is called the surge flow. The surge controller then attempts to control the flow to the Centrifugal Compressor at some percent above the surge flow (this is typically 10%). The surge controller essentially acts like PID Controller operations. The control algorithms used to prevent Centrifugal Compressors from surging are extensions of the PID algorithm. Figure 9.179-43 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-44 Centrifugal Compressor or ww ThTwo major differences distinguish a surge from a regular controller: • The setpoint of the surge controller is calculated and not set. • More aggressive action is taken by the surge controller if the Centrifugal Compressor is close to surging. Connections Tab The Connections tab is very similar to a PID controller’s Connections tab. The inlet volumetric flow to the Centrifugal Compressor is automatically defaulted as the process variable (PV) to be measured. You must select a Control Valve operation as an operating variable (OP), which has a direct effect on the inlet flow to the Centrifugal Compressor. The Upstream Surge Controller Output field contains a list of the other surge controllers in the simulation flowsheet. If you select an upstream surge controller using the Upstream Surge Controller Output field, HYSYS ensures that the output signal of the Centrifugal Compressor’s surge controller is not lower than an upstream surge controller’s output signal. Consider a situation in which two compressors are connected in series. For more information on the individual parameters which make up the Connections tab, refer to Chapter 5 - Logical Operations Figure 9.189-44 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-45 ww ThAs shown in the previous figure, both surge controllers must use the same valve for surge control. If the surge controllers are connected in this manner HYSYS autoselects the largest controller output. This is done to ensure that surge control is adequately provided for both compressors. Parameters Tab The parameters tab consists of the following pages: • Configuration • Surge Control Configuration Page If the process variable (PV) is operating above a certain margin over the surge flow limit, the surge controller operates exactly as a PID Controller. Therefore, PID control parameters should be set on the Configuration page. The process variable range, the controller action, operation mode, and the tuning parameters of the controller can be set in this page. For more information on the individual fields in the Configuration page, refer to Section 5.4.4 - PID Controller.9-45 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-46 Centrifugal Compressor or ww ThSurge Control Page Various surge control parameters can be specified on the Surge Control page. A head versus quadratic flow expression relates the surge flow to the head of the Centrifugal Compressor. where: Fs = surge flow (m3/s) hm = head of the Centrifugal Compressor A, B, C, D = parameters used to characterize the relationship between surge flow and head You can enter surge flow parameters A, B, C, and D in order to characterize the relationship between the surge flow and head. Figure 9.19 (9.17)hm A B Fs( ) C Fs( )2 D Fs( )3+ + +=9-46 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-47 ww ThThe next three parameters in the Surge Control Parameters section are defined as follows: Monitor Tab The Monitor tab displays a chart that graphs the three variables (PV, SP, and OP) of the surge controller User Variables Tab The User Variables tab enables you to create and implement your own user variables for the current operation. Holdup Page Typical Centrifugal Compressors and Expanders in actual plants usually have significantly less holdup than most other unit operations in a plant. Therefore, the volume of the Centrifugal Compressor or Expander operation in HYSYS cannot be specified and is assumed to be zero on the Holdup page. Stripchart Page The Stripchart page allows you to select and create default strip charts containing various variable associated to the operation. Surge Control Parameter Description Control Line (%) The primary setpoint for the surge controller. This line is defaulted at 10% above the surge flow. If the flow is above the backup line then the surge controller acts as a normal PID controller. Backup Line (%) Set somewhere between the control line and the surge flow. This line is defaulted at 5% above the surge flow. If the flow to the Centrifugal Compressor falls below the backup line, more aggressive action is taken by the controller to prevent a surge condition. Quick Opening (%/sec) Aggressive action is taken by increasing the desired actuator opening at a rate specified in this field until the volumetric flow to the Centrifugal Compressor rises above the backup line. For more information refer to Section 1.3.8 - User Variables Page/ Tab. Refer to Section 1.3.3 - Holdup Page for more information. Refer to Section 1.3.7 - Stripchart Page/Tab for more information.9-47 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-48 Reciprocating Compressor ww Th9.2 Reciprocating Compressor In Section 9.1 - Centrifugal Compressor or Expander a Centrifugal Compressor type is presented. The following section discusses a Reciprocating Compressor. A Reciprocating Compressor is just another type of compressor used for applications where higher discharge pressures and lower flows are needed. It is known as a positive displacement type. Reciprocating Compressors have a constant volume and variable head characteristics, as compared to the Centrifugal Compressor that has a constant head and variable volume. In HYSYS, Centrifugal and Reciprocating Compressors are accessed via the same compressor unit operation. However, the solution methods differ slightly as a Reciprocating Compressor does not require a compressor curve and the required geometry data. The present capability of Reciprocating Compressors in HYSYS is focused on a single stage compressor with a single or double acting piston. A typical solution method for a Reciprocating Compressor is as follows: • Always start with a fully defined inlet stream, in other words, inlet pressure, temperature, flow rate, and compositional data are known. • Specify compressor geometry data, for example, number of cylinders, cylinder type, bore, stroke, and piston rod diameter. HYSYS provides default values too. • Compressor performance data, in other words, adiabatic efficiency or polytropic efficiency, and constant volumetric efficiency loss are specified. • HYSYS calculates the duty required, outlet temperature if the outlet pressure is specified. For Reciprocating Compressors there is no direct relationship between the head and flow capacity.9-48 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-49 ww ThSome of the features in the dynamic Reciprocating Compressor unit operation include: • Dynamic modeling of friction loss and inertia. • Dynamic modeling which supports shutdown and startup behaviour. • Dynamic modeling of the cylinder loading. • Linking capabilities with other rotational equipment operating at the same speed with one total power. 9.2.1 Theory In a single stage Reciprocating Compressor, it comprises of the basic components like the piston, the cylinder, head, connecting rod, crankshaft, intake valve, and exhaust valve. This is illustrated in Figure 9.20. HYSYS is capable of modeling a multi-cylinder in one Reciprocating Compressor with a single acting or double acting piston. A single acting compressor has a piston that is compressing the gas contained in the cylinder using one end of the piston only. A double acting compressor has a piston that is compressing the gas contained in the cylinder using both ends of the piston. The piston end that is close to the crank is called crank end, while the other is named as outer. The thermodynamic calculations for a Reciprocating Compressor are the same as a Centrifugal Compressor. Basically, there are two types of compression being considered: Figure 9.209-49 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-50 Reciprocating Compressor ww Th• Isentropic/adiabatic reversible path. A process during which there is no heat added to or removed from the system, and the entropy remains constant. PVk=constant, where k is the ratio of the specific heat (Cp/Cv). • Polytropic reversible path. A process in which changes in the gas characteristic during compression are considered. Details of the equation are found in Section 9.1.1 - Theory. Reference1 has the information about the operation of the Reciprocating Compressor. The performance of the Reciprocating Compressor is evaluated based on the volumetric efficiency, cylinder clearance, brake power, and duty. Cylinder clearance, C, is given as: where: PD = positive displacement volume The sum of all clearance volume for all cylinders includes both fixed and variable volume. C is normally expressed in a fractional or percentage form. The piston displacement, PD, is equal to the net piston area multiplied by the length of piston sweep in a given period of time. This displacement can be expressed as follows: • For a single-acting piston compressing on the outer end only: (9.18) (9.19) C Sum of all clearance volume for all cylinders PD -----------------------------------------------------------------------------------------------------------= PD π D2 stroke⋅ ⋅ 4 ---------------------------------=9-50 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-51 ww Th• For a single-acting piston compressing on the crank end only: • For double-acting piston (other than tail rod type): • For a double-acting piston (tail rod type): where: d = piston rod diameter D = piston diameter PD includes the contributions from all cylinders and both ends of any double acting. If a cylinder is unloaded then its contribution does not factor in. The volumetric efficiency is one of the important parameters used to evaluate the Reciprocating Compressor's performance. Volumetric efficiency, VE, is defined as the actual pumping capacity of a cylinder compared to the piston displacement volume. VE is given by: (9.20) (9.21) (9.22) (9.23) PD π D2 d2–( ) stroke⋅ ⋅ 4 -------------------------------------------------= PD π 2D2 d2–( ) stroke⋅ ⋅ 4 ----------------------------------------------------= PD π 2D2 2d2–( ) stroke⋅ ⋅ 4 --------------------------------------------------------= VE 1 L–( ) C Zs Zd ----- Pd Ps -----⎝ ⎠ ⎛ ⎞ 1 k -- 1––=9-51 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-52 Reciprocating Compressor ww Thwhere: Pd = discharge pressure Ps = suction pressure L = effects of variable such as internal leakage, gas friction, pressure drop through valves, and inlet gas preheating k = heat capacity ratio, Cp/Cv Zd = discharge compressibility factor Zs = suction compressibility factor C = clearance volume To account for losses at the suction and discharge valve, an arbitrary value about 4% VE loss is acceptable. For a non- lubricated compressor, an additional 5% loss is required to account for slippage of gas. If the compressor is in propane, or similar heavy gas service, an additional 4% should be subtracted from the volumetric efficiency. These deductions for non-lubricated and propane performance are both approximate, and if both apply, cumulative. Thus, the value of L varies from (0.04 to 0.15 or more) in general.9-52 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-53 ww ThRod Loading Rod loads are established to limit the static and inertial loads on the crankshaft, connecting rod, frame, piston rod, bolting, and projected bearing surfaces. It can be calculated as follows: Maximum Pressure The maximum pressure that the Reciprocating Compressor can achieve is: Where the maximum discharge pressure ratio, PRmax, is calculated from: Figure 9.21 Load in compression, Lc (9.24) Load in tension, Lt (9.25) (9.26) (9.27) Lc PdAp Ps Ap Ar–( )–= Lt Pd Ap Ar–( ) PsAp–= Pmax Ps PRmax⋅= PRmax Zd Zs C⋅ ------------- 1 L– VE– C+( ) k = 9-53 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-54 Reciprocating Compressor ww ThFlow Flow into the Reciprocating Compressor is governed by the speed of the compressor. If the speed of the compressor is larger than zero then the flow rate is zero or larger then zero (but never negative). The molar flow is then equal to: where: N = speed, rpm = gas density MW = gas molecular weight If the speed of the compressor is exactly zero, then the flow through the unit is governed by a typical pressure flow relationship, and you can specify the resistance in zero speed flow resistance, kzero speed. The flow equation is as follows: where: = frictional pressure drop across the compressor (9.28) (9.29) F 1 L 100 --------–⎝ ⎠ ⎛ ⎞ C Zs Zd ----- Pd Ps -----⎝ ⎠ ⎛ ⎞ 1 k -- 1–– N 60 ----- PD ρ⋅⋅ MW --------------------------= ρ F kzero speed ρ ΔPfriction⋅⋅= ΔPfriction9-54 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-55 ww Th9.2.2 Reciprocating Compressor Property View There are two ways that you can add a Compressor to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Rotating Equipment radio button. 3. From the list of available unit operations, select Compressor. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the Compressor icon. The Compressor property view appears. Figure 9.22 Compressor icon9-55 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-56 Reciprocating Compressor ww ThDo one of the following to complete the Reciprocating Compressor installation: • On the Design tab, click the Parameters page. Select the Reciprocating radio button in the Operating Mode group. • On the Dynamics tab, click on the Specs page. Select the Reciprocating (Positive Displacement) checkbox in the Dynamic Specifications group. 9.2.3 Design Tab The Design tab contains the following pages: • Connections • Parameters • Links • Settings • User Variables • Notes Connections Page The Connections page allows you to specify the inlet stream, outlet stream, and energy stream. Figure 9.23 The Connections page is identical to the Connections page for the Centrifugal Compressor property view. Refer to the section on the Centrifugal Compressor or Expanders Connections Page for more information.9-56 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-57 ww ThParameters Page The Parameters pages is identical to the Centrifugal Compressor as shown in the figure below. You can specify the duty of the attached energy stream on this page, or allow HYSYS to calculate it. The adiabatic and polytropic efficiencies appear as well. Figure 9.24 The difference between the Centrifugal and Reciprocating compressor is the missing Curve Input Option group. You can switch between Centrifugal and Reciprocating Compressor by selecting one of the radio buttons in the Operating Mode group. You can specify only one efficiency, either adiabatic or polytropic. If you specify one efficiency and a solution is obtained, HYSYS back calculates the other efficiency, using the calculated duty and stream conditions. The Reciprocating Compressor has a higher adiabatic efficiency than the Centrifugal Compressor, normally in the range of 85% - 95%. Maximum pressure ratio can be achieved at zero volume efficiency.9-57 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-58 Reciprocating Compressor ww ThLinks Page The Links page is identical to the Centrifugal Compressor as shown in the figure below. Settings Page The Settings page is used to size the Reciprocating Compressor. Figure 9.25 Figure 9.26 Refer to Links Page section for more information.9-58 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-59 ww ThA Reciprocating Compressor does not require a characteristic curve, however the following compressor geometry information is required: • Number of Cylinders • Cylinder Type • Bore • Stroke • Piston Rod Diameter • Constant Volumetric Efficiency Loss • Default Fixed Clearance Volume • Zero Speed Flow Resistance (k) - dynamics only • Typical Design Speed • Volumetric Efficiency • Speed Depending on the cylinder type selected, you have four parameters that can be specified. If the cylinder type is of double action, you need to specify the fixed clearance volume for the crank side and the outer side. • Fixed Clearance Volume • Variable Clearance Volume • Variable Volume Enabled • Cylinder is Unloaded - dynamics only The Settings page is only visible when you have activated the Reciprocating Compressor option either from the Parameters page on the Design tab or the Specs page on the Dynamics tab. Bore is the diameter of the cylinder. Stroke is the distance head of piston travels. Typical Design Speed is the estimated speed for the rotor. Speed is the actual speed of the rotor.9-59 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-60 Reciprocating Compressor ww ThIf the Variable Volume Enabled checkbox is selected, you need to specify a variable clearance volume. If the Cylinder is Unloaded checkbox is selected, the total displacement volume is not considered and is essentially zero. The Size k button allows you to access the Reciprocating Pressure-Flow Sizing property view, and specify a pressure drop and mass flow rate that is used to calculate the zero speed flow resistance of the Reciprocating Compressor. User Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. The variable clearance volume is used when additional clearance volume (external) is intentionally added to reduce cylinder capacity. Figure 9.27 For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.9-60 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-61 ww Th9.2.4 Rating Tab The Rating tab contains the following pages: • Nozzles • Inertia • Electric Motor Nozzles Page If you are working exclusively in Steady State mode, you are not required to change any information on the Nozzles page. The Nozzles page in the Reciprocating Compressor is identical to the Nozzles page in the Centrifugal Compressor. Inertia Page If you are working exclusively in Steady State mode, you are not required to change any information on this page. The Reciprocating Compressor Inertia page is identical to the one for the Centrifugal Compressor. Electric Motor If you are working exclusively in Steady State mode, you are not required to change any information on this page. The Reciprocating Compressor Electric Motor page is identical to the one for the Centrifugal Compressor. Refer to the section on the Nozzles Page for more information. Refer to the section on the Inertia Page for more information. Refer to the section on the Electric Motor Page for more information.9-61 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-62 Reciprocating Compressor ww Th9.2.5 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. 9.2.6 Performance Tab The Performance tab consists of the Results page. Results Page On the Results page, you can view a table of calculated values for the Compressor. In the Results group you will find the following fields: • Adiabatic Head • Polytropic Head • Adiabatic Efficiency • Polytropic Efficiency • Power Consumed • Friction Loss • Rational Inertia • Fluid Power • Polytropic Head Factor • Polytropic Exponent • Isentropic Exponent • Speed In the Reciprocating group you will find the following fields: • Total Effective Piston Displacement Volume • Total Effective Fractional Clearance Volume • Maximum Pressure Ratio • Load in Compression • Load in Tension The PF Specs page is relevant to dynamics cases only. Refer to Section 1.3.10 - Worksheet Tab for more information.9-62 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-63 ww Th9.2.7 Dynamics Tab The Dynamics tab is identical to the one for the Centrifugal Compressor. However, when using a Reciprocating Compressor you cannot use the Characteristic Curves specification or create a Surge Controller. 9.3 Pump The Pump operation is used to increase the pressure of an inlet liquid stream. Depending on the information specified, the Pump calculates either an unknown pressure, temperature or pump efficiency. The dynamics Pump operation is similar to the Compressor operation in that it increases the pressure of its inlet stream. The Pump operation assumes that the inlet fluid is incompressible. Some of the features in the dynamic Pump include: • Dynamic modeling of friction loss and inertia. • Dynamic modeling which supports shutdown and startup behaviour. • Multiple head and efficiency curves. • Modeling of cavitation if Net Positive Suction Head (NPSH) is less than a calculated NPSH limit. • Linking capabilities with other rotational equipment operating at the same speed with one total power. If you are working exclusively in Steady State mode, you are not required to change any information on the pages accessible through the Dynamics tab. Refer to Section 9.1.7 - Dynamics Tab for more information.9-63 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-64 Pump ww Th9.3.1 Theory HYSYS uses the following assumptions and equations in calculating the unknown Pump unit operation variables. • Calculating the ideal power of the pump required to raise the pressure of the liquid: The calculations are based on the standard pump equation for power, which uses the pressure rise, the liquid flow rate, and density: where: Pout = pump outlet pressure Pin = pump inlet pressure • Calculating the actual power of the pump: The actual power requirement of the Pump is defined in terms of the Pump Efficiency: When the efficiency is less than 100%, the excess energy goes into raising the temperature of the outlet stream. Combining the above equations leads to the following expression for the actual power requirement of the Pump: The actual power is also equal to the difference in heat flow between the outlet and inlet streams: (9.30) (9.31) (9.32) Power Requiredactual = (Heat Flowoutlet - Heat Flowinlet) (9.33) Power Requiredideal Pout Pin–( ) Flow Rate× Liquid Density --------------------------------------------------------------= Efficiency %( ) Power Requiredideal Power Requiredactual -------------------------------------------------------- 100%×= Power Requiredactual Pout Pin–( ) Flow Rate 100%×× Liquid Density Efficiency %( )× -----------------------------------------------------------------------------------=9-64 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-65 ww ThThe pump calculations that HYSYS performs assume that the liquid is incompressible. The density is constant, and the liquid volume is independent of pressure. This is the usual assumption for liquids well removed from the critical point, and the standard pump equation given above is generally accepted for calculating the power requirement. However, if you want to perform a more rigorous calculation for pumping a compressible liquid (for example, one near the critical point), you should install a compressor to represent the pump. If you choose to represent a Pump by installing a Compressor in HYSYS, the power requirement and temperature rise of the Compressor is always greater than those of the Pump (for the same fluid stream), because the compressor treats the liquid as a compressible fluid. When the pressure of a compressible fluid increases, the temperature also increases, and the specific volume decreases. More work is required to move the fluid than if it were incompressible, exhibiting little temperature rise, as is the case with a HYSYS Pump. The ideal power required, W, to increase the pressure of an incompressible fluid is: where: P1 = pressure of the inlet stream P2 = pressure of the exit stream = density of the inlet stream F = molar flow rate of the stream MW = molecular weight of the fluid (9.34) For a pump, an efficiency of 100% does not correspond to a true isentropic compression of the liquid. W P2 P1–( )F MW( ) ρ ------------------------------------------= ρ 9-65 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-66 Pump ww Th9.3.2 Pump Property View There are two ways that you can add a Pump to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Rotating Equipment radio button. 3. From the list of available unit operations, select Pump. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the Pump icon. The Pump property view appears. The On checkbox enables you activate or deactivate the pump. This checkbox has different meanings, depending on whether you are in steady state or dynamic operations. Figure 9.28 Pump icon9-66 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-67 ww ThIn Steady State mode: • Selected On checkbox indicates the Pump is on and works as normal. (Default setting) • Cleared On checkbox indicates the Pump is off and the inlet stream passes through the pump operation unchanged. In other words, the outlet stream is exactly the same as the inlet stream. In Dynamics mode: • Selected On checkbox indicates the Pump is on and works as normal. (Default setting) • Cleared On checkbox will set the Electric Motor torque and power to 0.0. In Steady State mode, the On checkbox is always available. In Dynamic mode, the On checkbox is only available for the following situations: • Pump speed is being used as a dynamic spec. (This requires that curves are used as a dynamic spec.) • Power is being used as a dynamic spec. • Electric motor is being used. If the pump speed and power are not specified and the electric motor is not being used, the On checkbox will be grayed out. When you use the On option in either Steady State or Dynamic modes, you should specify a pressure rise rather than specify the pressures of the inlet stream and outlet stream. If you specify a Delta P, this value is simply ignored when you turn the Pump off. If you specify the pressures of the inlet stream and outlet stream, you get a consistency error when you turn the Pump off, as HYSYS attempts to pass the inlet stream conditions to the outlet stream.9-67 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-68 Pump ww Th9.3.3 Design Tab The Design tab consists of the following pages: • Connections • Parameters • Curves • Links • User Variables • Notes Connections Page On the Connections page, you can specify the pump name, fluid package, and inlet, outlet, and energy streams of the Pump. Parameters Page The Parameters page enables you to specify the adiabatic efficiency, Delta P, and pump energy (power) parameters. However, if the inlet stream is fully defined, only two of the following variables need to be specified for the Pump to calculate all unknowns: • Outlet Pressure or Pressure Drop (pressure difference between inlet and outlet stream) • Efficiency (pump efficiency) • Pump Energy or Duty (actual power) Figure 9.299-68 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-69 ww ThHYSYS can also back-calculate the inlet pressure. Curves Page The Curves page allows you to configure the pump based on the pump curve. On the Curves page, you can create the pump curve using the equation provided by the pump manufacturer. Figure 9.30 Figure 9.319-69 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-70 Pump ww ThTo generate a pump curve: 1. On the Curves page, select the units for the Head, Flow Basis, and Flow Rate variables. 2. Enter the coefficients for the quadratic pump equation. The coefficient values come from the pump manufacture. 3. Select the Activate Curves checkbox. Based on the calculated pump curve results, HYSYS determines the pressure rise across the Pump for the given flowrate. Phasing out one method Currently HYSYS Pump operation provides two methods to generate pump curve data in Steady State: curve equation and curve characteristics. • The curve equation function was originally provided in older versions of HYSYS (before 2004 release). The function was limited to a pump curve data generated by the curve equation, which may not accurately reflect the actual pump operating behavior. • The curve characteristics function enables users to directly describe the pump operating behavior in terms of Flow, Head, Efficiency, and speed issues. By entering these variable values, a more accurate pump curve data is achieved. For the details of the curve characteristics concept, please refer to the Compressor section. The Activate Curves checkbox can only be selected if the Use Curves checkbox in the Curves page of the Rating tab is clear. To avoid a consistency error, ensure that you have not specified the pressure rise across the Pump, either in the attached streams or in the operation itself.9-70 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-71 ww ThIf an old case is loaded into HYSYS and the old case contained converged pumps that use curve equation to generate the pump curves, HYSYS automatically populates a curve characteristic set to generate a new pump curve similar to the old pump curve based on the curve equation specifications. A warning message also appears informing you about the new pump curve and suggesting that you switch to the curve characteristic method. To switch to the curve characteristic method: 1. Open the Pump property view. 2. Click on the Design tab and select the Curves page. 3. Clear the Activate Curves checkbox. 4. Click on the Rating tab and select the Curves page. 5. Click the Use Curves checkbox. 6. Click on the Design tab and select the Parameters page. 7. Delete any specified values in the Adiabatic Efficiency field or Duty field. HYSYS does not automatically replace the new pump curve with the old pump curve. HYSYS supports both methods, however the curve equation method will eventually be phased out.9-71 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-72 Pump ww ThLinks Page In HYSYS, Pumps can have shafts which are physically connected. The rotational equipment linker operates both in Steady State and Dynamic mode. The following table lists and describes the objects in the Links page: Figure 9.32 Object Description Previous Link field Displays the HYSYS rotating equipment operation connected on one side of the shaft. Next Link drop- down list Allows you to select a rotating equipment operation to connect on the other side of the shaft. Gear Ratio field Displays the ratio of the speed from the next linked operation divided by the speed of the current pump. Total Power Loss field Depending on the configuration of the pump and the information specified, you can either: • View the total power loss of the linked operation. • Specify the total power loss of the linked operation. Dynamic Specification checkbox Allows you to specify the total power loss (or power gain by entering a negative value) for the linked operation. You can ignore this option in Steady State mode. It is not significant which order the Pumps are linked. The notion of previous and next links is arbitrary and determined by the user.9-72 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-73 ww ThLinked Pump operations require curves. In Dynamics mode, to fully define a set of linked operations, you must select the Use the Characteristic Curves checkbox for each of the linked Pumps in the Specs page of the Dynamics tab. In Dynamics mode when you link rotating operation, the pressure flow equations are affected as follow: • An energy conservation equation is set such that the sum of the operation powers equals the total power. • Each pair of operation has their speeds set to equal. One additional dynamic specification is usually required for the set. The total power loss from the linked operations can be specified. For a series of linked Pumps, it is desired to input a total power: An electric motor connected to the current operation or a linked operation can also supply the total power. User Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. Total Power Input = - Total Power Loss (9.35) It is possible to link a Pump to a Compressor and use the Pump as a turbine to generate kinetic energy to drive the Compressor. If this option is selected, the total power loss is typically specified as zero. For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.9-73 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-74 Pump ww Th9.3.4 Rating Tab If you are working exclusively in Steady State mode, you are not required to change any information on most of the pages accessible through the Rating tab. The Rating tab consists of the following pages: • Curves • NPSH • Nozzles • Inertia • Electric Motor • Startup Curves Page The Curves page on the Rating tab allows you to configure the pump based on pump curve characteristics generated by the pump manufacturer. The curve characteristics consist of pump efficiency, pump head, pump flow rate, and pump speed variables. The pump can be configured based on multiple pump curves and speeds. The pump curve characteristics method works in both steady state and dynamic mode. Figure 9.339-74 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-75 ww ThThe following table lists and describes the objects in the Curves page: Depending on the type of pump curve you want to generate the following information needs to be supplied for the pump to solve: • For a performance curve (one curve), the feed temperature and pressure must be supplied along with one of flow, duty, outlet pressure or efficiency. • For normalized curves, the feed temperature and pressure must be specified along with two of flow, speed, duty, outlet pressure, and efficiency. Object Description Curve Name column Displays the names of the curve data for the pump. View Curve button Allows you to open the Curve Property View and modify the curve characteristic of the selected curve. This button is only available if there is a curve available in the Curve Name column. Add Curve button Opens the Curve Property View and allows you to create a curve. Delete Curve button Allows you to delete the selected curve in the Curve Name column. This button is only available if there is a curve available in the Curve Name column. Clone Curve button Allows you to duplicate an existing curve. Plot Curves button Allows you to generate a plot of all the curve in the Curves Profiles Property View. Generate Curves button Allows you to manipulate and generate the curve using the Generate Curve Options Property View. This option should be used only if the pump curve data is not provided by the manufacturer. Pump Speed field Enables you to specify a pump speed for all the curve data. Use Curves checkbox Enables you to accept the pump curve data generated by the curve characteristics. The Use Curves checkbox can only be selected if the Activate Curves checkbox is clear in the Curves page of the Design tab. For the two variables, either flow and/or speed must be specified. A pump with duty and efficiency specified can not be solved using the curve characteristic option.9-75 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-76 Pump ww ThIn addition, if outlet pressure or efficiency is supplied as one of the variables (for performance or normalized curves) and their corresponding curve is a parabola or has multiple flows for a given pressure or efficiency, then there may be multiple solutions. HYSYS will notify you of this possibility but will still solve to the first solution only. If iterations are required, basically any problems that do not have both flow and speed specified for a normalized problem or no flow for a performance problem, then HYSYS deploys the Secant method to converge to a solution. The number of maximum iterations is set at 10000 and is not modifiable. To specify data for a pump curve: 1. On the Curves page, click the Add Curve button, the Curve property view appears. 2. On the Curve property view, specify the pump speed in the Speed field. 3. Specify the flow, head, and %efficiency data points for a single curve in the appropriate cells. 4. For each additional curve, repeat step #1 and #2. • Click the Erase Selected button to delete the entire row (Flow, Head or Efficiency) of the selected cell. • Click the Erase All button to delete all Flow, Head, and Efficiency data for the curve. 5. After entering all your curve data, click the Close icon to return to the Pump property view. Figure 9.349-76 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-77 ww ThHYSYS uses the curve(s) to determine the appropriate efficiency for your operational conditions. If you specify curves, ensure the Efficiency values on the Parameters page of the Design tab are empty, or a consistency error will be generated. Curve Property View You can access the Curve property view by: • Clicking the Add Curve button. • Selecting a curve data and clicking the View Curve button. In the Curve property view, you can specify the following data: Figure 9.35 Object Description Name field Enables you to designate a name for particular curve characteristic data. Speed field Enables you to specify the rotation speed of the pump. This value is only required if you specify more than one set of curve characteristic data. Each set of curve characteristic data is associated to a specific pump rotation speed. Flow Units field Enables you to select the unit of the flow rate for the curve characteristic data. Head Units field Enables you to select the unit of the head for the curve characteristic data. Flow column Enables you to specify the flow rate data of the pump curve. The flow rate values appear along the x-axis of the pump curve plot. Head column Enables you to specify the head data of the pump curve. The head values appear along the y-axis of the pump curve plot.9-77 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-78 Pump ww ThIn order to run a stable and realistic dynamic model, HYSYS requires you to input reasonable curves. If Compressors or Expanders are linked, it is a good idea to ensure that the curves plotted for each unit operation span a common speed and capacity range. Typical curves are plotted in the figure below. where: h = pump head Efficiency column Enables you to specify the efficiency data of the pump curve. The pump efficiency values appear along the y-axis of the pump curve plot. Erase Selected button Enables you to select a cell and erase the data in the entire row associated to the selected cell. Erase All button Enables you to delete all the flow, head, and efficiency data of the curve. The curve characteristics data is normally provided by the pump manufacturer. HYSYS can interpolate values for the efficiency and head of the Compressor or Expander for speeds that are not plotted. Object Description Figure 9.369-78 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-79 ww Th= pump efficiency Capacity = pump flow rate Curves Profiles Property View The Curves Profiles property view allows you to see the plot of the curve data. To access the Curves Profiles property view, click the Plot Curves button on the Curves page in the Rating tab of the Pump property view. The following table lists and describes the objects available in the Curves Profiles property view: Figure 9.37 Object Description Plot Displays the selected curve data in plot format. Head radio button Allows you to view the Head vs. Flow curve data plot. Efficiency radio button Allows you to view the Efficiency vs. Flow curve data plot. Curve Name column Displays the names of the curve data available for the plot. Plot checkboxes Allows you to toggle between displaying and hiding the associate curve data in the plot. Show Operating Pt checkbox Allows you to toggle between displaying and hiding the curve data generated by the Pump’s current operating conditions and specifications. η 9-79 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-80 Pump ww ThGenerate Curve Options Property View The Generate Curve Options property view allows you to generate curve data based on the specified pump design parameters. HYSYS automatically generates three curves based on three different speeds: user specified speed, user specified speed multiplied by low speed %, and user specified speed multiplied by low low speed %. Each curve is generated using the following data point assumptions: • A point based on the Head of the pump, Capacity of the pump, and the assumption that shutoffhead (0 flow rate) occurs at 110% of the Design Head value (the 110% comes from the Design Head Factor variable). • A point based on the Head of the pump, Capacity of the pump, and the assumption that maximum flow (0 Head) occurs at 200% of the design capacity flow rate (the 200% comes from the Design Flow Factor variable). • A point based on the following expression: • A point based on the following expression: • A point based on the following expression: (9.36) (9.37) (9.38) capacity efficiency,( ) 0 design efficiency factor efficiency design×,( )= capacity efficiency,( ) design flow efficiency design,( )= capacity efficiency,( ) design flow factor design flow× efficiency design design efficiency factor× ,( ) = 9-80 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-81 ww ThTo access the Generate Curve Options property view, click the Generate Curves button on the Curves page in the Rating tab of the Pump property view. The following table lists and describes the objects available in the Generate Curve Options property view: Figure 9.38 Object Description Design Efficiency Factor cell Allows you to manipulate the pump design efficiency factor. Default value is 0.90. Design Efficiency cell Allows you to manipulate the design efficiency of the pump. HYSYS provides a default value of 70%. Design Flow Factor cell Allows you to manipulate the pump design flow factor. Default value is 2. Design Flow cell Allows you to manipulate the pump design flow. Default value is 10. Design Head Factor cell Allows you to manipulate the pump design Head factor. Default value is 1.10. Design Head cell Allows you to specify the design Head of the pump. Design Speed cell Allows you to specify the design speed of the pump. Low Speed cell Allows you to manipulate the pump low speed based on the percentage value of the pump design speed. Default value is 60%. Low Low Speed cell Allows you to manipulate the pump low low speed based on the percentage value of the pump design speed. Default value is 30%. Generate Curves button Allows you to generate the curve data based on the specified pump design. Any previous specified curve data in the Curves page of the Rating tab will be deleted, when you generate the new curve data. Cancel button Allows you to exit the Generate Curves Options property view without generating any curve data.9-81 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-82 Pump ww ThNPSH Page Net Positive Suction Head (NPSH) is an important factor to consider when choosing a Pump. Sufficient NPSH is required at the inlet of the Pump to prevent the formation of small bubbles in the pump casing which can damage the Pump. This is known as cavitation. For a given Pump, the net positive suction head required to prevent cavitation, NPSHrequired, is a function of the capacity (volumetric flowrate) and speed of the Pump. In HYSYS, NPSH curves can be specified like regular pump curves on the NPSH page. To add or edit a NPSH curve from the NPSH page: 1. Select the Enable NPSH curves checkbox. 2. Click the Add Curve button, the NPSH Curve property view appears. 3. Specify the speed for each curve. The default values in the Required Data table are provided as an example. The variable values must be changed to reflect the data of the pump the user wants to simulate. The user data is normally provided by the pump manufacturer or by the design specifics for the simulation. The default values in the Optional Curve Shape Data table are for a typical pump used in a plant. Figure 9.399-82 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-83 ww Th4. Enter a capacity and NPSH for two points on the curve. Only two points are required for the NPSH curves since: 5. To remove all the data points, click the Erase All button. 6. For each additional curve, repeat steps #2 to #4. The NPSHrequired value can either be taken from the NPSH curves or specified directly in the NPSH required field. To directly specify the NPSHrequired, you must first clear the Enable NPSH curves checkbox. NPSHavailable can be explicitly calculated from the flowsheet conditions by clicking the Calculate Head button. The NPSHavailable is calculated as follows: where: P1 = inlet stream pressure to the pump Pvap = vapour pressure of the inlet stream = density of the fluid V1 = velocity of the inlet stream g = gravity constant (9.39) Figure 9.40 (9.40) NPSHrequired( ) capacity( )log∝log NPSHavailable P1 Pvap– ρg ---------------------- V1 2g ----- 2 ⎝ ⎠ ⎛ ⎞+= ρ 9-83 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-84 Pump ww ThTo prevent pump cavitation the NPSHavailable must be above the NPSHrequired. If a pump cavitates in HYSYS, it is modeled by scaling the density of the fluid, , randomly between zero and one. Nozzles Page The Nozzles page contains information regarding the elevation and diameter of the nozzles. For a Pump unit operation it is strongly recommended that the elevation of the inlet and exit nozzles are equal. If you want to model static head, the entire piece of equipment can be moved by modifying the Base Elevation relative to Ground Elevation field. Inertia Page The inertia modeling parameters and the frictional loss associated with the impeller in the Pump can be specified on this page. The HYSYS Dynamics license is required to use the Inertia features. Electric Motor Page The Electric Motor page allows you to drive your rotating unit operation through the designation of a motor torque versus speed curve. These torque vs. speed curves can either be obtained from the manufacturer for the electric motor being used or from a typical curve for the motor type. For most process industry applications, a NEMA type A or B electric motor is used. When you use the Electric Motor option the torque (and power) generated by the motor is balanced against the torque consumed by the rotating equipment. ρ Refer to Section 1.3.6 - Nozzles Page for more information. Refer to Section 1.6.4 - Inertia in the HYSYS Dynamic Modeling guide for more information.9-84 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-85 ww Th The following table lists and describes the objects in the Electric Motor page: The Electric Motor functionality is only relevant in Dynamics mode. The Electric Motor option uses one degree of freedom in your dynamic specifications. The results of the Electric Motor option are presented on the Power Page in the Performance Tab of the rotating equipment operation. Figure 9.41 Object Description Synchronous Speed cell Allows you to specify the synchronous speed of the motor. Full Load Speed cell Allows you to specify the design speed of the motor. Full Load Torque cell Allows you to specify the design torque of the motor. Full Load Power cell Allows you to specify the design power of the motor. Gear Ratio cell Allows you to manipulate the gear ratio. The gear ratio is the rotating equipment’s speed divided by the motor speed. Motor Inertia cell Allows you to specify the motor inertia. Motor Friction Factor cell Allows you to specify the motor friction factor. User Electric Motor checkbox Allows you to toggle between using or ignoring the electric motor functionality.9-85 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-86 Pump ww ThTheory The definition of torque is found from the following equation: where: P = power consumption (kW) T = torque (Nm) = synchronous speed (rpm) Speed vs Torque Curve button Allows you to view the plot and specify the data in the Speed vs. Torque Curve Property View. Size Inertia button Allows you to calculate the inertia based on the following equation: where: I = inertia ( ) P = full load power of the motor (kW) N = full load speed of the motor (rpm/1000) Simple radio button Allows you to select the Simple model for the modelling option. Breakdown radio button Allows you to select the Breakdown model for the modelling option. Electric Brake checkbox Allows you to model the torque force on the rotating equipment simply by changing the sign of the produced torque value. Gearing checkbox Allows the gear ratio to be updated during integration. A zero value for the gear ratio indicates a decoupling of the equipment. (9.41) Object Description I 0.0043 P N ---⎝ ⎠ ⎛ ⎞ 1.48 = kg m3⋅ Refer to Operation Model section for more information. P T ω 2 π××× 1000 60× --------------------------------= ω 9-86 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-87 ww ThThe synchronous electric motor speed can be found from: where: f = power supply frequency (Hz), typically either of 50 or 60 p = number of poles on the stator The number of poles is always an even number of 2, 4, 6, 8, 10, and so forth. In North America, common motor speeds are always 3600, 1800, 1200, 900, 720, and so forth. The relationships of inertia and friction loss in the total energy balance are the same as for the pump and compressor operations. Operation Model There are three ways to use the Electric Motor curve, each with progressing rigor. • Simple Model. The easiest calculation is the Simple modelling option (default). This model is useful if you just want to model the startup/shutdown transient and want to keep the equipment at the fixed full load speed once operating. In this mode, once the speed has accelerated enough to become larger than the last (largest) curve speed value entered, the motor speed immediately is set to the full load speed and remains there until the motor is turned off. If the process invokes a larger torque than the motor curve suggests the motor can produce, the speed still remains synchronous and remains at its full load value. • Breakdown Model. The Breakdown modelling option allows the speed to reduce if the system torque or resistance gets too large. To use this option, the largest (last) curve speed value entered should be just less than the full load speed value. This provides for a smooth transition in operation. You can drop the curve to a lower torque than the breakdown torque if desired. • Simple Model Modified. The third modelling approach is to use the Simple model option, but enter the speed vs torque curve up to a speed value of 99.99% of the synchronous speed. In this case the full load speed (9.42)ω 120f p ----------=9-87 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-88 Pump ww Thentered is only used, if necessary, to calculate the full load torque and is not used otherwise. With this approach, the speed vs torque curve must ascend or drop from the breakdown torque to approach zero torque at 100% speed. For most motor types, this approach is nearly vertical (asymptotic). This modelling approach allows for the simulation of the slippage of the motor speed based upon the actual and current system resistance. The operating speed of the motor will then move based upon the process model operation. Use a near vertical curve to keep a constant speed or level it off more to allow greater slip. This performance should be predicted by using an accurate manufacturers torque vs speed curve. Speed vs. Torque Curve Property View The Speed vs. Torque Curve property view displays the data curve of speed versus torque in both table and plot format. To access the Speed vs. Torque Curve property view, click the Speed vs Torque Curve button on the Electric Motor page of the Rating tab. The speed and torque are not solved simultaneously with the pressure flow solution but instead is lagged by a time step. You may need to use a smaller time step to ensure accuracy and pressure flow solver convergence. Figure 9.429-88 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-89 ww ThThe following table lists and describes the objects available in the Speed vs. Torque Curve property view: Design Page The Design page allows you to specify the typical or design operating capacity, pump speed, and power consumption. • Typical operating capacity cell allows you to specify a value used to assist pump start up priming when vapor is present in the inlet stream. • Design Speed cell allows you to specify the speed value used for the Auto Pump Curve generation feature and the pump inertia sizing. • Design Power cell allows you to specify the power value used for the Auto Pump Curve generation feature and for pump inertia sizing. The values under the Speed and Torque columns are entered as a percent of the Full Load values. The Speed vs. Torque curve must always contain a 0% speed value. During integration, the current operating point appears on the Torque vs. Speed curve. The maximum table speed cannot be greater than the value in the Maximum X value field. The Maximum X value is the ratio of the full load speed to the synchronous speed. Object Description Maximum X value display field Displays the ratio of the full load speed to the synchronous speed. Speed column Allows you to specify speed percentage values you want to plot. Torque column Allows you to specify the torque percentage values associated with the speed. Erase Selected button Allows you to delete the row containing both speed and torque percentage values of the selected cell. Erase All button Allows you to delete all the values in the table. The HYSYS Dynamics license is required to use the options in the Design page. Refer to Section 1.6.6 - Design in the HYSYS Dynamic Modeling guide for more information.9-89 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-90 Pump ww Th9.3.5 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. 9.3.6 Performance Tab The Performance tab contains the calculated results of the pump. Results Page The Results page contains pump head information. The values for total head, pressure head, velocity head, Delta P excluding static head, total power, friction loss, rotational inertia, and fluid power are calculated values. The Total Head field is used only for dynamic simulation. Figure 9.43 The PF Specs page is relevant to dynamics cases only. Refer to Section 1.3.10 - Worksheet Tab for more information.9-90 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-91 ww ThPower Page The Power page displays the following calculated values: • pump rotor power variables • pump rotor torque variables • electric motor power variables (if applicable) • electric motor torque variables (if applicable) • other electric motor data (if applicable) 9.3.7 Dynamics Tab The Dynamics tab is used only for dynamic simulation. The Dynamic tab contains the following pages: • Specs • Holdup • Stripchart Specs Page The dynamic specifications of the Pump can be specified on the Specs page. If you are working exclusively in Steady State mode, you are not required to change any of the values on the pages accessible through the Dynamics tab. Figure 9.449-91 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-92 Pump ww ThIn general, two specifications should be selected in the Dynamics Specifications group in order for the Pump operation to fully solve. You should be aware of specifications, which may cause complications or singularity in the pressure flow matrix. Some examples of such cases are: • The Pressure rise checkbox should not be selected if the inlet and exit stream pressures are specified. • The Speed checkbox should not be selected if the Use Characteristic Curves checkbox is not selected. The possible dynamic specifications are as follows: Head The ideal head, h, can easily be defined as a function of the isentropic or polytropic work. The relationship is: where: W = ideal pump power MW = molecular weight of the gas F = molar flow rate of the inlet stream g = gravity acceleration or using Equation (9.34), the head is defined as: If pump curves are provided in the Curves page of the Rating tab, the ideal head can be interpolated from the flow of gas and the speed of the pump. (9.43) (9.44) W MW( )Fgh= h P2 P1– ρg -----------------=9-92 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-93 ww ThFluid Head The Fluid Head is the produced head in units of energy per unit mass. Speed The rotational speed of the shaft, , driving the Pump can be specified. Efficiency The efficiency is given as the ratio of the ideal power required by the pump to the actual energy imparted to the fluid. The efficiency, , is defined as: The ideal power required by the pump is provided in Equation (9.34). The general definition of the efficiency does not include the losses due to the rotational acceleration of the shaft and seal losses. Therefore, the efficiency equations in dynamics are not different at all from the general efficiency equations defined in Section 9.3.1 - Theory. If pump curves are provided in the Curves page of the Rating tab, the efficiency can be interpolated from the flow of gas and the speed of the Pump. Pressure Rise A Pressure Rise specification can be selected, if the pressure drop across the Pump is constant. (9.45) ω η η W F MW( ) h2 h1–( ) --------------------------------------=9-93 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-94 Pump ww ThPower The duty is defined as the power required to rotate the shaft and provide energy to the fluid. The duty has three components: The duty should be specified only if there is a fixed rate of energy available to be used to drive the shaft. Capacity The capacity is defined as the actual volumetric flow rate entering the Pump. Use Characteristic Curves Select the Use Characteristic Curves checkbox, if you want to use the curve(s) specified in the Curves page of the Rating tab. If a single curve is specified in a dynamics Pump, the speed of the Pump is not automatically set to the speed of the curve. A different speed can be specified, and HYSYS extrapolates values for head and efficiency. Pump is acting as turbine Select the Pump is acting as turbine checkbox, if you want the pump to act as a turbine with a pressure drop from inlet to outlet. Duty = Power supplied to the fluid + Power required to change the rotational speed of the shaft + Power lost due to mechanical friction loss (9.46)9-94 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Rotating Operations 9-95 ww ThLinker Power Loss Select the Linker Power Loss checkbox, if you want to specify the power loss (negative for a power gain) of the linked operations. Electric Motor Select the Electric Motor checkbox if you want to use the electric motor functionality. Holdup Page Typical pumps in actual plants usually have significantly less holdup than most other unit operations in a plant. Therefore, the volume of the Pump operation in HYSYS cannot be specified, and is assumed to be zero on the Holdup page. Stripchart Page The Stripchart page allows you to select and create default strip charts containing various variable associated to the operation. 9.4 References 1 Gas Processors Association. Gas Processors Suppliers Association (1998) p.13-1 to p13-20 2 Campbell M.John. Gas Conditioning and Processing (vol2) 7th edi. 1994, p213-221 3 Thorley A. R. D. Fluid Transients in Pipeline Systems. D & L George Ltd. England, 1991. Refer to Section 1.3.3 - Holdup Page for more information. Refer to Section 1.3.7 - Stripchart Page/Tab for more information.9-95 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 9-96 References ww Th9-96 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-1 ww Th10 Separation Operations10-1 10.1 Component Splitter ...................................................................... 2 10.1.1 Theory .................................................................................. 2 10.1.2 Component Splitter Property View ............................................ 3 10.1.3 Design Tab ............................................................................ 4 10.1.4 Rating Tab ........................................................................... 10 10.1.5 Worksheet Tab ..................................................................... 10 10.1.6 Dynamics Tab ...................................................................... 10 10.2 Separator, 3-Phase Separator, & Tank ....................................... 12 10.2.1 Theory ................................................................................ 14 10.2.2 Separator General Property View ............................................ 17 10.2.3 Design Tab .......................................................................... 18 10.2.4 Reactions Tab....................................................................... 21 10.2.5 Rating Tab ........................................................................... 22 10.2.6 Worksheet Tab ..................................................................... 45 10.2.7 Dynamics Tab ...................................................................... 45 10.3 Shortcut Column ........................................................................ 51 10.3.1 Shortcut Column Property View .............................................. 51 10.3.2 Design Tab .......................................................................... 52 10.3.3 Rating Tab ........................................................................... 55 10.3.4 Worksheet Tab ..................................................................... 55 10.3.5 Performance Tab .................................................................. 55 10.3.6 Dynamics Tab ...................................................................... 56 10.4 References................................................................................. 56 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-2 Component Splitter ww Th10.1 Component Splitter With a Component Splitter, a material feed stream is separated into two component streams based on the parameters and split fractions that you specify. You must specify the fraction of each feed component that exits the Component Splitter into the overhead product stream. Use it to approximate the separation for proprietary and non-standard separation processes that are not handled elsewhere in HYSYS. 10.1.1 Theory The Component Splitter satisfies the material balance for each component: where: fi = molar flow of the ith component in the feed ai = molar flow of the ith component in the overhead bi = molar flow in the ith component in the bottoms The molar flows going to the overhead and bottoms are calculated as: where: xi = split, or fraction of component i going to the overhead Once the composition, vapour fraction, and pressure of the outlet streams are know, a P-VF flash is performed to obtain the temperatures and heat flows. fi = ai + bi (10.1) ai = xi fi (10.2) bi = (1-xi ) fi (10.3)10-2 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-3 ww ThAn overall heat balance is performed to obtain the energy stream heat flow: where: hE = enthalpy of unknown energy stream hF = enthalpy of feed stream hO = enthalpy of overhead stream hB = enthalpy of bottoms stream 10.1.2 Component Splitter Property View There are two ways that you can add a Component Splitter to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Short Cut Columns radio button. 3. From the list of available unit operations, select the Component Splitter model. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the Component Splitter icon. hE = hF - hO - hB (10.4) Component Splitter icon10-3 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-4 Component Splitter ww ThThe Component Splitter property view appears. 10.1.3 Design Tab The Design tab contains the following pages: • Connections • Parameters • Splits • TBP Cut Point • User Variables • Notes Each of the pages are discussed in the following sections. Figure 10.110-4 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-5 ww ThConnections Page You can specify an unlimited number of inlet streams to the Component Splitter on the Connections page. You must specify the overhead outlet stream, bottoms outlet stream, and an unlimited number of energy streams. One of the attached energy streams should have an unspecified energy value to allow the operation to solve the energy balance. Parameters Page The Parameters page displays the stream parameters. You must specify the stream parameters, which include the vapour fraction, pressure of the overhead stream, and pressure of the bottoms stream. Figure 10.2 Figure 10.310-5 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-6 Component Splitter ww ThTo specify the Component Splitter parameters: 1. Click one of the following radio buttons to calculate the outlet stream parameters: - Calculate Equal Temperatures – HYSYS calculates equal temperatures for both the Overhead and Bottoms streams. You cannot select this option if you have multiple overhead streams. - Use Stream Flash Specifications – HYSYS uses the stream specifications to calculate the outlet stream conditions. 2. Click one of the following radio buttons to calculate the Overhead and Bottoms stream pressures: - Use Stream Pressure Specifications – You must supply the pressure for each of the outlet streams. - Equalize All Stream Pressures – HYSYS gives all the attached streams the same pressure after one of the attached streams is known. - Use Lowest Feed Pressure for All Products – HYSYS assigns the lowest inlet pressure to the outlet stream pressure. All but one outlet stream pressure must be known. To avoid consistency errors, remember to delete relevant specifications when chosing your Component Splitter parameters. Splits Page The Splits page allows you to specify the separation fraction of 10-6 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-7 ww Ththe outlet streams. The Splits, or separation fractions ranging from 0 to 1, must be specified for each component in the overhead stream exiting the Component Splitter. The quantity in the bottoms product is set once the overhead fraction is known. The two buttons on the Splits page, All 1 and All 0, allow you to specify overhead fractions of one (100%) or zero (0%), respectively, for all components. These buttons are useful if many components are leaving entirely in either the overhead stream or bottoms stream. For example, if the majority of your components are going overhead, simply click the All 1 button, rather than repeatedly entering fractions of 1. Then, correct the splits appropriately for the components not leaving entirely in the overhead. Figure 10.410-7 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-8 Component Splitter ww ThTBP Cut Point Page The TBP Cut Point page allows you to specify the compositions of the product streams by providing the TBP Cut Point between the streams, and assuming that there is sharp separation at the cut point. On the TBP Cut Point page, the upper table allows you to specify the initial TBP Cut Point on the Feed for each product stream except for the overhead. The Initial Cut Point values are expressed in temperature and they are listed in ascending order. Consecutive streams can have the same Initial Cut Point value, implying that the second or subsequent stream has zero flow. The bottom table allows you to specify the split fraction for each component in the stream. The split fraction values are also available on the Splits page of the Design tab. Pure components are distributed according to their NBP (Natural Boiling Point) while the TBP (True Boiling Point) of the pure Figure 10.5 You can specify a temperature cut point of 0 K and higher. The TBP Cut Point Page is designed for streams with hypothetical components.10-8 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-9 ww Thcomponents defines the boundaries of distribution. The NBP for each component is displayed in the NBP table for reference. The TBP Cut Point page is designed for handling streams that carry hypocomponents. The hypocomponents are treated as a continuum and they are distributed according to their FBP (Final Boiling Point). The FBP of each hypocomponent is first calculated by sorting the NBP of the hypocomponents in ascending order. Then with the sorted order, the FBP of the last hypocomponent is calculated as follows: The FBPs for other hypocomponents is calculated by: The hypocomponents are then distributed according to where the cut point lies. The boiling range for each hypocomponent is defined by the FBP of the previous component to the FBP of the current component. The boiling range for each product stream is from its Initial TBP Cut Point to the Initial TBP Cut Point of the next stream. User Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. (10.5) (10.6) FBPlast NBPlast NBPlast NBPlast 1––( )+= FBPi NBPi NBPi 1++ 2 -------------------------------------------= For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.10-9 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-10 Component Splitter ww Th10.1.4 Rating Tab You cannot provide any information for the Component Splitter on the Rating tab when in steady state. Nozzles Page The Nozzles page contains information regarding the elevation and diameter of the nozzles. 10.1.5 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. 10.1.6 Dynamics Tab Information available on this page is relevant only to cases in Dynamic mode. The Dynamics tab consists of the Specs page. The PF Specs page is relevant to dynamics cases only. For more information, refer to Section 1.3.6 - Nozzles Page. Refer to Section 1.3.10 - Worksheet Tab for more information.10-10 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-11 ww ThSpecs Page The Specs page contains information regarding pressure specifications of the streams. The Equal Pressures checkbox allows you to propagate the pressure from one stream to all others. If you want to equalize the pressures you have to free up the pressure specs on the streams that you want the pressure to be propagated to. The Vessel Volume is also specified on this page. This volume is only used to affect the compositional affects in this operation. The Pressure - Flow and hydraulics are not affected by this value. This volume is only a simplified and synthetic way of getting some lag in the compositional affects. The thermal state (temperature and enthalpy) of the outlet streams may or may not be affected by this value depending on the other specifications of this operation. For example, if you have specified the outlet stream temperatures directly, then this volume has no affect, on the other hand if the operation is doing some flash with an external duty (of value zero or otherwise), then this volume has an affect. Figure 10.610-11 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-12 Separator, 3-Phase Separator, & ww Th10.2 Separator, 3-Phase Separator, & Tank The property views for the Separator, 3-Phase Separator, and Tank are similar, therefore, the three unit operations are discussed together in this section. There is an Operation Type toggle option on the Parameters page of the Design tab that allows you to easily switch from one of these operations to another. For example, you may want to change a fully defined Separator to a 3-Phase Separator. Simply, select the appropriate radio button in the Operation Type toggle option. The only additional information required would be to identify the additional liquid stream. All of the original characteristics of the operation (Parameters, Reactions, and so forth) are retained. The key differences in the three separator operations are the stream connections (related to the feed separation), which are described in the table below. All information in this section applies to the Separator, the 3- Phase Separator, and the Tank operation, unless indicated otherwise. Unit Operation Description Separator Multiple feeds, one vapour and one liquid product stream. In Steady State mode, the Separator divides the vessel contents into its constituent vapour and liquid phases. 3-Phase Separator Multiple feeds, one vapour and two liquid product streams. The 3-Phase Separator operation divides the vessel contents into its constituent vapour, light liquid, and heavy liquid phases. Tank Multiple feeds, one liquid and one vapour product stream. The Tank is generally used to simulate liquid surge vessels.10-12 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-13 ww ThIn Dynamic mode, the following unit operations all use the holdup model and therefore, have many of the same properties. Vessel operations in HYSYS have the ability to store a significant amount of holdup. The key differences in the vessel operations are outlined in the table below. Every dynamic vessel operation in HYSYS has some common features including: • The geometry of the vessel and the placement and diameter of the attached feed and product nozzles have physical meaning. • A heat loss model which accounts for the convective and conductive heat transfer that occurs across the vessel wall. • Various initialization modes which allow you to initialize the vessel at user-specified holdup conditions before running the integrator. • Various Heater types which determine the way in which heat is transferred to the vessel operation. Unit Operation Description Separator The Separator can have multiple feeds. There are two product nozzles: • liquid • vapour. 3-Phase Separator The 3-Phase Separator can have multiple feeds. There are 3 product nozzles: • light liquid • heavy liquid • vapour. Tank The Tank can have multiple feeds. There are two product nozzles which normally removes liquid and vapour from the Tank. Condenser The condenser has one vapour inlet stream. The number and phase of each exit stream depends on the type of condenser. The condenser has a unique method of calculating the duty applied to its holdup. Reboiler The reboiler has one liquid inlet stream. The reboiler can have a number of liquid and vapour exit streams. Reactors Reactor operations can have multiple inlet and exit streams. Heat Exchanger (Simple Rating Model, Detailed) A shell or tube with a single pass in the heat exchanger unit operation can be modeled with a liquid level. Both the shell and tube sides of the heat exchanger have one inlet and one exit stream.10-13 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-14 Separator, 3-Phase Separator, & ww Th10.2.1 Theory A P-H flash is performed to determine the product conditions and phases. The pressure at which the flash is performed is the lowest feed pressure minus the pressure drop across the vessel. The enthalpy is the combined feed enthalpy plus or minus the duty (for heating, the duty is added; for cooling, the duty is subtracted). As well as standard forward applications, the Separator and 3- Phase Separator have the ability to back-calculate results. In addition to the standard application (completely defined feed stream(s) being separated at the vessel pressure and enthalpy), the Separator can also use a known product composition to determine the composition(s) of the other product stream(s), and by a balance the feed composition. In order to back-calculate with the Separator, the following information must be specified: • One product composition. • The temperature or pressure of a product stream. • Two (2-phase Separators) or three (3-phase Separators) flows. If you are using multiple feed streams, only one feed stream can have an unknown composition in order for HYSYS to back-calculate.10-14 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-15 ww ThEnergy Balance In Steady State mode Separator energy balance is defined below: where: Hfeed = heat flow of the feed stream(s) Hvapour = heat flow of the vapour product stream Hlight = heat flow of the light liquid product stream Hheavy = heat flow of the heavy liquid product stream Physical Parameters The Physical Parameters associated with this operation are the pressure drop across the vessel and the vessel volume. The pressure drop across the vessel is defined as: where: P = vessel pressure Pv = pressure of vapour product stream Pl = pressure of liquid product stream(s) Pfeed = pressure of feed stream the pressure is assumed to be the lowest pressure of all the feed streams = pressure drop in vessel Phead = pressure of the static head (10.7) The default pressure drop across the vessel is zero. (10.8) Hfeed Duty± Hvapour Hheavy Hlight+ += P Pl Pfeed ΔP– Phead Pv+= = = ΔP10-15 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-16 Separator, 3-Phase Separator, & ww ThThe vessel volume, together with the set point for liquid level/ flow, defines the amount of holdup in the vessel. The amount of liquid volume, or holdup, in the vessel at any time is given by the following expression where: PV(%Full) = liquid level in the vessel at time t Ideal vs. Real In ideal separators, complete/perfect separation between the gas and liquid phases is assumed. In real world separators, separation is not perfect: liquid can become entrained in the gas phase and each liquid phase may include entrained gas or entrained droplets of the other liquid phase. Recent years have seen increasing use of vessel internals (for example, mesh pads, vane packs, weirs) to reduce the carry over of entrained liquids or gases. By default the HYSYS separators are ideal separators, however, you can modify the separators to model imperfect separation by using the HYSYS Real Separator capabilities. The real separator offers you a number of advantages: • Carry Over options so that your model matches your process mass balance or separator design specifications. • Options to predict the effect of feed phase dispersion, feed conditions, vessel geometry, and inlet / exit devices on carry over. (10.9) The Vessel Volume is necessary in steady state when modeling a Reactor (CSTR), as it determines the residence time. Holdup Vessel Volume PV %Full( ) 100 ----------------------------×= Refer to Section 10.2.5 - Rating Tab for information on the options used to configure a real separator.10-16 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-17 ww Th10.2.2 Separator General Property View There are two ways that you can add a Separator, 3 -Phase Separator, or Tank to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Vessels radio button. 3. From the list of available unit operations, select the Separator, 3 Phase Separator, or Tank. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the Separator icon or 3 Phase Separator icon or Tank icon. The Separator or 3 Phase Separator or Tank property view appears. Figure 10.7 Separator icon 3-Phase Separator icon Tank icon10-17 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-18 Separator, 3-Phase Separator, & ww Th10.2.3 Design Tab The Design tab contains options for configuring the separator operation. Connections Page The Connections page allows you to specify the streams flowing into and out of the separator operation, the name of the separator operation, and the fluid package associated to the separator operation. Depending on the type of heat transfer you want to make available for the separator operation, the options available in the Connections page varies. You are required, however, to always specify the following variables: • Name of the separator operation • Name of the feed streams • Name of the vapor product stream • Name of the liquid product stream(s) • Name of the fluid package of the separator operation If you want to use the Separator as a reactor, you can either install a Separator or choose General Reactor from the UnitOps property view. Any of the HYSYS separator operations accept multiple feed streams, as well as an optional energy stream.10-18 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-19 ww ThThe figure below shows the Connections pages for the three separator operations: Figure 10.8 Three Phase Separator with energy stream attached. Separator with kettle reboiler or chiller attached. Tank with no energy stream attached.10-19 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-20 Separator, 3-Phase Separator, & ww ThParameters Page The Parameters page allows you to specify the pressure drop across the vessel. The following table lists and describes the options available in this page: Figure 10.9 Object Description Inlet cell Allows you to specify the pressure difference across the vessel. Vapour outlet cell Allows you to specify the static head pressure of the vessel. Volume Field Allows you to specify the volume of the vessel. The default vessel volume is 2 m3. Liquid Volume Display Field Not set by the user. The Liquid Volume is calculated from the product of the Vessel Volume and Liquid Level fraction. Liquid Level SP Field Allows you to specify the starting point of the liquid level in the vessel. This value is expressed as a percentage of the Full (Vessel) Volume. Type Group Allows you to toggle between the Separator, 3-Phase Separator, and Tank by clicking the appropriate radio button. If you toggle from a 3 Phase Separator operation to a Separator or Tank operation, you permanently lose the heavy liquid stream connection. If you change back to the 3 Phase Separator, you have to reconnect the heavy liquid stream.10-20 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-21 ww ThUser Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. 10.2.4 Reactions Tab The Reactions tab contains options for applying chemical reactions that can take place in the vessel. Results Page The Results page allows you to attach a reaction set to the Separator, 3-Phase Separator, or Tank Operations. If you select an alternate unit, your value appears in the face plate using HYSYS display units. Figure 10.10 For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.10-21 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-22 Separator, 3-Phase Separator, & ww ThIn the Reaction Set drop-down list, select the reaction set you want to use. Reaction and component information can also be examined in the Reaction Results group. Select the Reaction Balance radio button to view the total inflow, total reaction, and total outflow for all of the components in the reaction. Select the Reaction Extents radio button to view the Percent Conversion, Base Component, Equilibrium Constant, and Reaction Extent. You can also view information for specific reactions by clicking the View Global Rxn button. 10.2.5 Rating Tab The Rating tab includes options relevant in both Steady State and Dynamics modes. The options available are: • Configuring and calculating the separator’s vessel size. • Specifying and calculating heat loss. • Configuring level taps to observe relative levels of different liquid phases. • Specifying the PV work term contribution. • Configuring and calculating the Carry Over model. Sizing Page You can define the geometry of the unit operation on the Sizing page. Also, you can indicate whether or not the unit operation has a boot associated with it. If it does, then you can specify the boot dimensions. You must provide the following information for the separator operation when working in Dynamics mode: • vessel geometry • nozzle geometry • heat loss10-22 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-23 ww ThAfter you specified the vessel’s dimension information in the appropriate field, click the Quick Size button to initiate the HYSYS sizing calculation for the vessel. Vessel Geometry In the Geometry group, you can specify the vessel orientation, shape, and volume. The geometry of the vessel is important in determining the liquid height in the vessel. There are four possible vessel shapes as described in the table below. Figure 10.11 Vessel Shape Description Flat Cylinder A cylindrical shape vessel that is available for either horizontal or vertical oriented vessel. You can either specify the total volume or any two of the following for the vessel: • total volume • diameter • height (length) If only the total cylindrical volume of the vessel is specified, the height to diameter ratio is defaulted as 3:2. Sphere A sphere shape vessel that is available for either horizontal or vertical oriented vessel. You can either specify the total volume or the diameter of the sphere.10-23 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-24 Separator, 3-Phase Separator, & ww ThThe liquid height in a vertical cylindrical vessel varies linearly with the liquid volume. There is a nonlinear relationship between the liquid height, and the liquid volume in horizontal cylindrical and spherical vessels. Weir A weir can be specified for the horizontal flat cylinder separator by selecting the Enable Weir checkbox and clicking the Weir button. The Initial Holdup property view appears. Ellipsoidal Cylinder A ellipsoidal cylindrical shape vessel that is only available for horizontal oriented vessel. You can either specify the total volume or any three of the following for the vessel: • total volume • diameter • length • ellipsoidal head height If only the total cylindrical volume of the vessel is specified, the height to diameter ratio is defaulted as 3:2. If the diameter or length is already specified, the only other variable that can be specified is the Ellipsoidal Head Height. Hemispherical Cylinder A hemispherical cylindrical shape vessel that is only available for horizontal oriented vessel. You can either specify the total volume or any two of the following for the vessel: • total volume • diameter • length If only the total cylindrical volume of the vessel is specified, the height to diameter ratio is defaulted as 3:2. The Enable Weir checkbox is only available for Flat Cylinder vessel shape option. Vessel Shape Description10-24 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-25 ww ThThe Initial Holdup property view allows you to specify the weir height and position. The weir position is the distance the weir is from the vessel feed side. HYSYS calculates the Levels and Phase Moles in each chamber using the specified values for the weir height and position. When HYSYS simulates, the weir has two volumes inside the Separator, called chamber 1 and chamber 2; but there is still only one enhanced holdup volume and moles as far as the pressure flow solver is concerned. This means that the compositions and properties of the phases in the two volumes are the same. Figure 10.12 Figure 10.1310-25 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-26 Separator, 3-Phase Separator, & ww ThBoot Geometry Any vessel operation can be specified with a boot. A boot is typically added when two liquid phases are present in the holdup. Normally, the heavy liquid exits from the boot exit nozzle. The lighter liquid can exit from another exit nozzle attached to the vessel itself. In HYSYS, a boot can be added to the vessel geometry by selecting the This Separator has a Boot checkbox. The boot height is defaulted to one third the vessel height. The boot diameter is defaulted to one third the vessel diameter. Nozzles Page The Nozzles page contains information regarding the elevation and diameter of the nozzles. Unlike steady state vessel operations, the placement of feed and product nozzles on a dynamic vessel operation has physical Figure 10.14 The HYSYS Dynamics license is required to use the Nozzle features found on the Nozzles page.10-26 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-27 ww Thmeaning. The composition of the exit stream depends on the exit stream nozzle location and diameter in relation to the physical holdup level in the vessel. • If the product nozzle is located below the liquid level in the vessel, the exit stream draws material from the liquid holdup. • If the product nozzle is located above the liquid level, the exit stream draws material from the vapour holdup. • If the liquid level sits across a nozzle, the mole fraction of liquid in the product stream varies linearly with how far up the liquid is in the nozzle. Essentially, all vessel operations in HYSYS are treated the same. The compositions and phase fractions of each product stream depend solely on the relative levels of each phase in the holdup and the placement of the product nozzles. So, a vapour product nozzle does not necessarily produce pure vapour. A 3-Phase Separator may not produce two distinct liquid phase products from its product nozzles. Heat Loss Page The Heat Loss page contains heat loss parameters which characterize the amount of heat lost across the vessel wall. Figure 10.1510-27 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-28 Separator, 3-Phase Separator, & ww ThIn the Heat Loss Model group, you can select one of the radio buttons to use as a model: • Simple • Detailed • None (no heat loss through the vessel walls). The Simple and Detailed heat loss models are discussed in the following sections. Simple Model The Simple model allows you to either specify the heat loss directly or have the heat loss calculated from specified values: • Overall U value • Ambient Temperature The heat transfer area, A, and the fluid temperature, Tf, are calculated by HYSYS. The heat loss is calculated using: where: U = overall heat transfer coefficient A = heat transfer area TAmb = ambient temperature For a Separator, the parameters available for the Simple model Q = UA(Tf - Tamb) (10.10)10-28 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-29 ww Thare shown in the figure below: The simple heat loss parameters are: • Overall Heat Transfer Coefficient • Ambient Temperature • Overall Heat Transfer Area • Heat Flow The Heat Flow is calculated as follows: where: U = overall heat transfer coefficient A = heat transfer area TAmb = ambient temperature T = holdup temperature As shown, Heat Flow is defined as the heat flowing into the vessel. The heat transfer area is calculated from the vessel geometry. The ambient temperature, TAmb, and overall heat transfer coefficient, U, can be modified from their default values shown in red. Figure 10.16 Heat Flow = UA(TAmb - T) (10.11)10-29 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-30 Separator, 3-Phase Separator, & ww ThDetailed Model The Detailed model allows you to specify more detailed heat transfer parameters. The HYSYS Dynamics license is required to use the Detailed Heat Loss model found on the Heat Loss page. Level Taps Page Since the contents in a vessel can be distributed in different phases, the Level Taps page allows you to monitor the level of liquid and aqueous contents that coexist within a specified zone in a tank or separator. Level Taps Specifications (Dynamics) The Level Tap Specifications (Dynamics) group allows you to The information available on this page is relevant only to dynamics cases. You can also define Level Taps for the lowest stage of a distillation column, as long as it is a Sump type. In the column subflowsheet, column property view, use the rating tab, level taps page. Figure 10.17 Refer to Section 1.6.1 - Detailed Heat Model in the HYSYS Dynamic Modeling guide for more information.10-30 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-31 ww Thspecify the boundaries to be monitored within the vessel, and to normalize that section in a desired scale. A level tap can be specified for any horizontal or vertical vessel by clicking the New Level Tap button. To set the boundaries of the section concerned, specify the following fields: By default, a new level tap is set to the total height of the vessel, and the height is normalized in percentage (100-0). Calculated Level Taps Values (Dynamics) The level of liquid and aqueous are displayed in terms of the output normalization scale you specified. Whenever the level of a content exceeds PV High, HYSYS automatically outputs the OP High value as the level of that content. If the level is below the PV Low, HYSYS outputs the OP Low value. The levels displayed You can add/configure multiple level taps. Field Description Level Tap Name of the level tap. PV High (m) Upper limit of the section to be monitored. It is expressed in meters. PV Low (m) Lower limit of the section to be monitored. It is expressed in meters. OP High Upper limit of the output of the normalization scale. OP Low Lower limit of the output of the normalization scale. The normalization scale can be negative values. In some cases, the output normalization scale is manually set between -7% to 100% or -15%-100% so that there is a cushion range before the level of the content becomes unacceptable (in other words, too low or too high). All the upper limit specifications should not be smaller than or equal to the lower limit specifications and vice versa; otherwise no calculations will be performed.10-31 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-32 Separator, 3-Phase Separator, & ww Thare always entrained within the normalized zone. Option Page The Options page allows you to specify and enable the PV Work Term Contribution. The PV Work Term Contribution is expressed in percent. It is approximately the isentropic efficiency. A high PV work term contribution value results in lower pressures, and temperatures. The PV work term contribution value should be between 87% to 98%. C.Over Setup Page The C.Over Setup page allows you to modify the separator operation from an ideal model to a real model. To achieve a real model separator, the C. Over Setup page enables you to configure the carry over effect in real separator operations. Carry over refers to the conditions when the liquid gets entrained in the vapour phase and/or when the gas gets entrained in the liquid phase. The effect is mainly caused by the disturbances created as the inlet stream enters the vessel. In HYSYS, the carry over effect is modelled using the entrainment fraction in the feed or product stream, or using the Figure 10.1810-32 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-33 ww Thavailable correlations that calculate carry over based on the vessel configuration. On the C. Over Setup page, you can select the type of carry over calculation model by clicking one of the following four radio buttons: • None (indicates that there is currently no carry over model applied to the associated vessel). • Feed Basis • Product Basis • Correlation Based There are two checkboxes available at the bottom of the page: • Carry Over to Zero Flow Streams. When you select this checkbox, the calculated carry over will be added to the product stream even if it has no flow. • Use PH Flash for Product Streams. When you select this checkbox, you apply a PH flash calculation to the product streams. This option is slower but it may be required to eliminate inconsistencies when one product flow is much less than the others. These two checkboxes are available in the Feed Basis, Product Basis, and Correlation Based models. The Feed Basis, Product Basis, and Correlation Based models are discussed in the following sections. Feed Basis Model The Feed Basis Model allows you to specify the entrainment of each phase in each product as a fraction of the feed flow of the 10-33 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-34 Separator, 3-Phase Separator, & ww Thphase. There are six types of carry over flow (in the feed and product streams) available for you to specify: • Light liquid in gas • Heavy liquid in gas • Gas in light liquid • Heavy liquid in light liquid • Gas in heavy liquid • Light liquid in heavy liquid The fractions containing non-zero values indicates the product streams exiting the separator will have multiple liquid and gas phases. For example, if you specify Fraction of Feed as 0.1 for light liquid in gas, this means that 10 mol% of the light liquid phase in the feed will be carried over into the gas product leaving the separator. As a result the gas product vapour fraction will be less than 1.0 and contain a liquid phase. Figure 10.19 The terms light liquid and heavy liquid refer to oil and water, respectively. No assumptions are made as to the actual composition of the two liquid phases.10-34 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-35 ww ThProduct Basis Model The Product Basis model allows you to specify the carry over entrainment in the product streams on fraction or flow basis. You can select the desired basis by clicking on one of the following radio buttons in the Specification By group: • Fraction. Allows you to specify the entrainment in the product stream as a fraction. The fraction basis is selected from the Basis drop-down list and may be either Mole, Mass, Liq.Volume or Actual Volume. • Flow. Allows you to specify the entrainment in the product streams as a flow. The flow basis may be specified using the Flow Basis drop-down list. The options are Mole, Mass, Liq.Volume or Actual volume. There are six types of carry over flow (in the feed and product streams) available for you to specify: • Light liquid in gas • Heavy liquid in gas • Gas in light liquid • Heavy liquid in light liquid • Gas in heavy liquid Figure 10.2010-35 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-36 Separator, 3-Phase Separator, & ww Th• Light liquid in heavy liquid For example, if you specify Frac in Product (Mole Basis) as 0.1 for the light liquid in gas, this means that the gas product will contain 10 mol% light liquid. In Steady State mode, if a phase is missing from the feed stream, selecting the Use 0.0 as product spec if phase feed flow is zero allows the separator to continue to calculate the carry over effect (in this example, carry over model calculation ignores any product fraction or flow specification for that phase). In Dynamics mode, the Use 0.0 as product spec if phase feed flow is zero feature is automatically and always active. Correlation Based Model The Correlation Based model allows you to calculate the expected carry over based on the configuration of the vessel, the feed conditions, and the operating conditions. The options available in the Correlation Based model allows you to configure the type of the correlation, dimensions and geometry of vessel, pressure drop methods, and nozzle location. The terms light liquid and heavy liquid refer to oil and water, respectively. No assumptions are made as to the actual composition of the two liquid phases.10-36 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-37 ww ThCorrelation Setup The Correlation Setup group allows you to select the Correlation Calculation Type, and how you want to apply the correlation. • You can apply one correlation for all of the carry over calculations by clicking on the Overall Correlation radio button. • If you want to select a different correlation for each carry over calculation steps (Inlet Device, Gas/Liq Separation, Liq/Liq Separation, and Vapour Exit Device), you can select the Sub Calculations radio button to activate the appropriate options. Figure 10.2110-37 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-38 Separator, 3-Phase Separator, & ww ThA schematic of these steps is shown in the figure below: For example, if the Generic correlation is used for the Inlet device and ProSeparator is used for primary L-L and G-L separation calculations, then the user supplied data for the generic inlet calculations (in other words, inlet split and Rossin Rammler parameters) will be used to Figure 10.22 Feed Gas Product Light Liquid Product Heavy Liquid Product Oil/Gas Water/Gas Inlet Calculations Oil distribution in Gas Water distribution in Gas Gas distribution in Oil Water distribution in Oil Gas distribution in Water Oil distribution in Water Oil/Gas Water/Gas Primary Gas- Liquid Separation Gas/Oil Water/Oil Gas/Water Oil/Water Primary Liquid- Liquid Separation Gas distribution in Oil Water distribution in Oil Gas distribution in Water Oil distribution in Water Gas/Oil Water/Oil Gas/Water Oil/Water Oil distribution in Gas Water distribution in Gas Oil/Gas Water/Gas Secondary Gas- Liquid Separation Oil distribution in Gas Water distribution in Gas Only those parts of the correlation in use that apply to the particular sub-calculation will be used.10-38 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-39 ww Thgenerate the inlet droplet dispersion. The ProSeparation primary separation calculations will then be performed using this inlet dispersion. As ProSeparator correlations will not be used to calculate the inlet conditions, any ProSeparator inlet setup data is ignored. Likewise, any critical droplet sizes entered in the Generic correlation will be ignored as the ProSeparator is being used for the primary separation calculations. There are three correlations available: Generic, Horizontal Vessel, and ProSeparator. After you have selected the type of correlation, you can click on the View Correlation button to view its calculation parameters. • Generic The Generic correlation provides a general correlation for generating the phase dispersions in the feed and defining the separation criteria. It is a generic calculation that is independent of the vessel dimensions, geometry, and operating levels. For the Inlet Calculations, you must define the percentage of each feed phase dispersed in each other phase. You must also define the maximum droplet sizes and Rosin Rammler index for each dispersion. The dispersions are then calculated using Rosin Rammler methods to give the amount of each phase in each droplet size range. For the rest of the carry over calculation, all droplets smaller than a user-specified critical droplet size are assumed to be carried over. The Generic correlation can be used for gas-liquid, liquid- liquid, and gas exit separation calculations. You must define the critical droplet size for each type of separation. Any droplets that are smaller than the specified critical droplet size will be carried over; the droplets that are larger than the critical droplet size will be separated. • Horizontal Vessel1 2 3 The Horizontal Vessel correlations were developed for a horizontal three-phase separator. For the Inlet Calculations, the correlations calculate the six types of dispersions in the feed according to an assumed efficiency of a user-defined inlet device, and user-defined dispersion fractions (termed Inlet Hold up; these parameters are found on the General page in the Setup tab of the Horizontal Vessel Correlation property view). The droplet distribution of the dispersed phase(s) is then calculated using user-supplied Rosin- Rammler parameters just as for the Generic correlation.10-39 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-40 Separator, 3-Phase Separator, & ww ThThe Primary Gas-Liquid Separation is calculated from the settling velocities for each liquid (light and heavy) droplet size in the gas phase and the residence time for the gas in the vessel. A droplet is carried over if the vertical distance travelled during its residence in the vessel is less than the vertical distance required to rejoin its bulk phase. The Primary Liquid-Liquid Separation is also calculated using settling velocities for each droplet of liquid or gas in the liquid phases and residence time for each liquid phase. The settling velocities are calculated using the GPSA correlations for all dispersions, except for the water in oil dispersion for which the settling velocity is calculated by the method of Barnea and Mizrahi. A user defined liquid phase inversion point is used in the calculation of the appropriate liquid phase viscosities (in other words, water-in-oil and oil-in-water). A residence time correction factor can also be applied. A droplet is carried over if the vertical distance travelled during its residence in the vessel is less than the vertical distance required to rejoin its bulk phase. The Secondary Separation calculations for the gas phase are defined by a user-defined critical droplet size. The gas loading factor for each device is used to calculate the size of the exit device. • ProSeparator4 The ProSeparator correlations are rigorous but are limited to calculating liquid carry over into gas. There are no calculations of liquid-liquid separation or gas entrainment in the liquid phases (they are set to zero). Light liquid and heavy liquid entrainments are calculated separately and the total carry over is the sum of the separate light and heavy liquid carry over calculations. For Inlet Calculations, minimum and maximum droplet diameter are calculated based on inlet flow conditions (inlet gas flow rate and gas-liquid phase physical properties) and inlet pipe size. The droplet distribution of light and heavy liquids in the inlet gas is then calculated using a Rosin-Rammler type distribution. The droplet d95 of the liquid-liquid dispersions (in other words, heavy liquid in light liquid and light liquid in heavy liquid) is not specified but calculated using the inlet droplet d95 and the densities of the 2 liquid phases.10-40 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-41 ww ThPrimary Gas-Liquid Separation is based on critical droplet size; however, the critical droplet size is not user- specified but calculated using gas velocity through the vessel. Secondary Gas-Liquid Separation accomplished using exit devices (for example, demisting pad) are calculated by device specific correlations. The user can choose from vane pack or mesh pad devices. There are 2 different calculation methods available for each type of device. Dimensions Setup The Dimensions Setup group allows you to set the orientation, and the geometry of the vessel. You can also set the operating levels for the light and heavy liquid in the vessel. You have the option to model the horizontal vessel with weir or a boot by selecting the Has Weir checkbox and Has Boot checkbox, respectively. ProSeparator effectively calculates its own Rossin Rammler parameters5 (droplet diameters) and does not require the user to specify these parameters. The only user input in the inlet calculations is the ability to limit the amount of phase dispersion calculated. Figure 10.2310-41 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-42 Separator, 3-Phase Separator, & ww ThDP/Nozzle Setup The Pressure Drop/Nozzle Setup group allows you to model the method of DP (pressure drop), and the geometry of the nozzles. In the Pressure Drop table, after you have selected a DP method from the drop-down list, you can activate the Inlet Device DP Method, and the Vapour Exit DP Method by selecting the Active checkbox. You can click on the View Method button to view the parameters of the DP method you have selected. Figure 10.24 Since the dynamic pressure and the pressure drop of the feed stream and vessel are specified in the Specs page of the Dynamics tab, the Pressure Drop table is not available when the separator is operating in dynamics mode.10-42 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-43 ww ThIn the Nozzle Diameter/Location table, you can set the diameter, height, and location for all the streams connected to the vessel. If a Correlation Based carry over model is selected: • the options on the DP / Nozzles Setup page can be used to calculate the inlet and exit nozzle pressure drop. • the user-specified pressure drops on the Parameters page of the Design tab can be used instead. C. Over Results Page The C. Over Results page allows you to view the carry over results in the feed, and product streams based on what you specified in the C. Over Setup page. There are four columns of data in the Carry Over Results table: • Frac. of Feed • Frac. in Product • Product Flow • Prod. Mass/Vol The C. Over Results page information is also available in Dynamic mode. Figure 10.2510-43 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-44 Separator, 3-Phase Separator, & ww ThThe units for Frac. of Feed, and Prod. Mass/Vol are set by default. You can change the unit for the Frac. in Product and Product Flow column by selecting one of the four units from the Product Basis drop-down list (Mole, Mass, Liq. Volume, and Actual Volume). You can view the carry over dispersion results by clicking on the View Dispersion Results button. The Carry Over Dispersion Results property view has two tabs: • Table. Displays the dispersion results for a single phase at a given point in the vessel. The radio buttons allow you to select the results of the corresponding phase. You can select the unit to be displayed from the Dispersion Basis drop-down list. • Plot. Provides a graphically interpretation of the dispersed quantity against the droplet size for a single dispersion. The Select Plot checkboxes allow you to select one or more dispersions to be plotted. You can select the dispersion basis from the Dispersion Basis drop-down list. Figure 10.2610-44 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-45 ww Th10.2.6 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. 10.2.7 Dynamics Tab Most of the options available on this tab is relevant only to cases in Dynamics mode. There is one exception, the Heat Exchanger Page allows you to specify whether or not the separator operation contains an energy stream used to heat or cool the vessel. Figure 10.27 The PF Specs page is relevant to dynamics cases only. Refer to Section 1.3.10 - Worksheet Tab for more information.10-45 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-46 Separator, 3-Phase Separator, & ww ThSpecs Page The Specs page contains information regarding initialization modes, vessel geometry, and vessel dynamic specifications. Model Details You can determine the composition and amount of each phase in the vessel holdup by specifying different initialization modes. HYSYS forces the simulation case to re-initialize whenever the initialization mode is changed. The radio buttons in the Model Details group are briefly described in the table below. Figure 10.28 Initialization Mode Description Initialize from Products The composition of the holdup is calculated from a weighted average of all products exiting the holdup. A PT flash is performed to determine other holdup conditions. The liquid level is set to the value indicated in the Liq Volume Percent field.10-46 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-47 ww ThIn the Model Details group, you can specify the vessel geometry parameters: • Vessel Volume • Vessel Diameter • Vessel Height (Length) • Liq Volume Percent You can modify the level in the vessel at any time. HYSYS then uses that level as an initial value when the integrator is run. • Vessel Geometry (Level Calculator) • Fraction Calculator Fraction Calculator The Fraction Calculator determines how the levels in the tank, and the elevation and diameter of the nozzles affect the product composition. The following is a description of the Fraction Calculator options: • Use Levels and Nozzles. The nozzle location and vessel phase (liquid/vapour) level determines how much of each phase, inside the vessel, will exit through that nozzle. For example, if a vessel contained both liquid and vapour phases and the nozzle is below the liquid level, then Dry Startup The composition of the holdup is calculated from a weighted average of all feeds entering the holdup. A PT flash is performed to determine other holdup conditions. The liquid level in the Liq Volume Percent field is set to zero. Initialize from User The composition of the liquid holdup in the vessel is user specified. The molar composition of the liquid holdup can be specified by clicking the Init Holdup button. The liquid level is set to the value indicated in the Liq Volume Percent field. The vessel geometry parameters can be specified in the same manner as those specified in the Geometry group for the Sizing page of the Rating tab. The Fraction Calculator defaults to the correct mode for all unit operations and does not typically require any changing. Initialization Mode Description For more information, see the section on Nozzles Page.10-47 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-48 Separator, 3-Phase Separator, & ww Thliquid will flow out through it. If the nozzle is above the liquid level, then vapour will flow out through it. • Emulsion Liquids. This behaves like the Use Levels and Nozzles option, except it simulates a mixer inside the vessel that mixes two liquid phases together so they do not separate out. For example, if a nozzle is below the lighter liquid level and the vessel has two liquid phases, the product is a mixture of both liquid phases. Dynamic Specifications The frictional pressure loss at the feed nozzle is a dynamic specification in HYSYS. It can be specified in the Feed Delta P field. The frictional pressure losses at each product nozzle are automatically set to zero by HYSYS. If you want to model friction loss at the inlet and exit stream, it is suggested you add valve operations. In this case, flow into and out of the vessel is realistically modeled. The vessel pressure can also be specified. This specification can be made active by selecting the checkbox beside the Vessel Pressure field. This specification is typically not set since the pressure of the vessel is usually a variable and determined from the surrounding pieces of equipment. It is recommended that you enter a value of zero in the Feed Delta P field because a fixed pressure drop in the vessel is not realistic for all flows.10-48 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-49 ww ThHoldup Page The Holdup page contains information regarding the properties, composition, and amount of the holdup. The Vessel Levels group displays the following variables for each of the phases available in the vessel: • Level. Height location of the phase in the vessel. • Percent Level. Percentage value location of the phase in the vessel. • Volume. Amount of space occupied by the phase in the vessel. Stripchart Page The Stripchart page allows you to select a default strip chart containing various variable associated to the operation. Figure 10.29 Refer to Section 1.3.3 - Holdup Page for more information. Refer to Section 1.3.7 - Stripchart Page/Tab for more information.10-49 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-50 Separator, 3-Phase Separator, & ww ThHeat Exchanger Page The Heat Exchanger page allows you to select whether the unit operation is heated, cooled, or left alone. You can also select the method used to heat or cool the unit operation. The options available in the Heat Exchanger page depends on which radio button you select: • If you select the None radio button, this page is blank and you do not have to specify an energy stream in the Connections page (from the Design tab) for the separator operation to solve. • If you select the Duty radio button, this page contains the standard heater or cooler parameters and you have to specify an energy stream in the Connections page (from the Design tab) for the separator operation to solve. • If you select the Tube Bundle radio button, this page contains the parameters used to configure a heat exchanger and you have to specify material streams in the Connections page (from the Design tab) for the separator operation to solve. Figure 10.30 Refer to Duty Radio Button for more information. Refer to Tube Bundle Radio Button for more information.10-50 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-51 ww Th10.3 Shortcut Column The Shortcut Column performs Fenske-Underwood short cut calculations for simple refluxed towers. The Fenske minimum number of trays and the Underwood minimum reflux are calculated. A specified reflux ratio can then be used to calculate the vapour and liquid traffic rates in the enriching and stripping sections, the condenser duty and reboiler duty, the number of ideal trays, and the optimal feed location. The Shortcut Column is only an estimate of the Column performance and is restricted to simple refluxed Columns. For more realistic results the rigorous Column operation should be used. This operation can provide initial estimates for most simple Columns. 10.3.1 Shortcut Column Property View There are two ways that you can add a Shortcut Column to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Short Cut Columns radio button. 3. From the list of available unit operations, select the Shortcut Column model. 4. Click the Add button. The Tube Bundle options are only available in Dynamics mode and for Separator and Three Phase Separator. If you switch from Duty option or Tube Bundle option to None option, HYSYS automatically disconnects the energy or material streams associated to the Duty or Tube Bundle options.10-51 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-52 Shortcut Column ww ThOR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click the Short Cut Distillation icon. The Shortcut Column property view appears. 10.3.2 Design Tab The Design tab contains the following pages: • Connections • Parameters • User Variables • Notes Figure 10.31 Short Cut Distillation icon10-52 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-53 ww ThConnections Page You must specify the feed stream, overhead product, bottoms product, condenser, and reboiler duty name on the Connections page. The overhead product can either be an overhead vapour or a distillate stream, depending on the radio button selected in the Top Product Phase group. The operation name can also be changed on this page. Parameters Page The Shortcut Column requires the light key and heavy key components to be defined. The light key is the more volatile component of the two main components that are to be separated. The compositions of the keys are used to specify the distillation products. Figure 10.32 You can specify the top product to be either liquid or vapour using the radio buttons in the Top Product Phase group. The composition of the light key in the bottoms and the heavy key in the overhead are the only composition specifications required.10-53 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-54 Shortcut Column ww ThIn the Components group, select the light key in bottoms and heavy key in distillation component from the drop-down list in the component cell, and specify their corresponding mole fraction. The specification must be such that there is enough of both keys to be distributed in the bottoms and overhead. It is possible to specify a large value for the light key composition such that too much of the light key is in the bottoms, and the overhead heavy key composition spec cannot be met. If this problem occurs, one or both of the key specs must be changed. In the Pressures group, you can define the column pressure profile by specifying a value in the Condenser Pressure field and a Reboiler Pressure field. In the Reflux Ratios group, the calculated minimum reflux ratio appears once streams are attached on the Connections page, and the required parameters are specified in the Components group and Pressures group. You can then specify an external reflux ratio, which is used to calculate the tray traffic, the condenser and reboiler duties, the ideal number of trays, and the optimum tray location. The external reflux ratio must be greater than the minimum reflux ratio. Figure 10.3310-54 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Separation Operations 10-55 ww Th10.3.3 Rating Tab You currently cannot provide any rating information for the Shortcut Column. 10.3.4 Worksheet Tab The Worksheet tab displays a summary of the information contained in the stream property view for all the streams attached to the operation. 10.3.5 Performance Tab The Performance tab allows you to examine the results of the Shortcut Column calculations. The results correspond to the external reflux ratio value that you specified on the Parameters page. The following results are available on the: Figure 10.34 Column Result Description Minimum Number of Trays The Fenske minimum number of trays, which is not affected by the external reflux ratio specification. Actual Number of Trays Calculated using a using the Gilliland method. Refer to Section 1.3.10 - Worksheet Tab for more information.10-55 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 10-56 References ww Th10.3.6 Dynamics Tab The Shortcut Column currently runs only in Steady State mode. As such, there is no information available on the Dynamics tab. 10.4 References 1 GPSA, Vol 1, 10th Ed., January 1990. 2 Separation Mechanism of Liquid-Liquid Dispersions in a deep-layer Gravity, Settler, E. Barnea and J Mizrahi, Trans. Instn. Chem. Engrs, 1975, Vol 53. 3 Droplet size spectra generated in turbulent pipe flow of dilute liquid- liquid dispersions, A J Karabelas, AIChE, 1978, vol. 24, No. 2, pages 170-181. 4 Society of Petroleum Engineers papers: SPE36647 – Separator Design and Operation: Tools for Transferring "Best Practise" SPE21506 – Proseparator – a novel separator/scrubber design program 5 Aspen Process Manuals – Mini Manual 1: Gas & Particle Properties; Part 8 – Particle Size 6 Aspen Process Manuals – Gas Cleaning Manual: Vol 1 – Introduction Vol 2 – Demisting Vol 10 – Applied Technology Optimal Feed Stage Top down feed stage for optimal separation. Condenser and Reboiler Temperatures These temperatures are not affected by the external reflux ratio specification. Rectifying Section Vapour and Liquid traffic flow rates The estimated average flow rates above the feed location. Stripping Section Vapour and Liquid traffic flow rates The estimated average flow rates below the feed location. Condenser and Reboiler Duties The duties, as calculated by HYSYS. Column Result Description10-56 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Solid Separation Operations 11-1 ww Th11 Solid Separation Operationsw.cadfamily.com EMa e document is for study 11.1 Baghouse Filter............................................................................ 3 11.1.1 Baghouse Filter Property View .................................................. 3 11.1.2 Design Tab ............................................................................ 4 11.1.3 Rating Tab ............................................................................. 6 11.1.4 Worksheet Tab ....................................................................... 7 11.1.5 Performance Tab .................................................................... 7 11.1.6 Dynamics Tab ........................................................................ 8 11.2 Cyclone ........................................................................................ 8 11.2.1 Cyclone Property View............................................................. 8 11.2.2 Design Tab ............................................................................ 9 11.2.3 Rating tab ........................................................................... 12 11.2.4 Worksheet Tab ..................................................................... 15 11.2.5 Performance Tab .................................................................. 15 11.2.6 Dynamics Tab ...................................................................... 15 11.3 Hydrocyclone ............................................................................. 16 11.3.1 Hydrocyclone Property View................................................... 16 11.3.2 Design Tab .......................................................................... 17 11.3.3 Rating tab ........................................................................... 20 11.3.4 Worksheet Tab ..................................................................... 21 11.3.5 Performance Tab .................................................................. 22 11.3.6 Dynamics Tab ...................................................................... 22 11.4 Rotary Vacuum Filter ................................................................. 22 11.4.1 Rotary Vacuum Filter Property View ........................................ 23 11.4.2 Design Tab .......................................................................... 24 11.4.3 Rating tab ........................................................................... 26 11.4.4 Worksheet Tab ..................................................................... 28 11.4.5 Dynamics Tab ...................................................................... 2811-1 il:cadserv21@hotmail.com only,if tort to your rights,please inform us,we will delete 11-2 Solid Separation Operations www.cadfamily.com EMa The document is for study 11.5 Simple Solid Separator ...............................................................29 11.5.1 Simple Solid Separator Property View ......................................29 11.5.2 Design Tab ...........................................................................30 11.5.3 Rating Tab............................................................................33 11.5.4 Worksheet Tab ......................................................................33 11.5.5 Dynamics Tab .......................................................................3311-2 il:cadserv21@hotmail.com only,if tort to your rights,please inform us,we will delete Solid Separation Operations 11-3 ww Th11.1 Baghouse Filter The Baghouse Filter model is based on empirical equations. It contains an internal curve relating separation efficiency to particle size. Based on your particle diameter, the reported separation efficiency for your solids is determined from this curve. The solids being separated must be previously specified and installed as components in the stream attached to this operation. 11.1.1 Baghouse Filter Property View There are two ways that you can add a Baghouse Filter to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Solids Handling radio button. 3. From the list of available unit operations, select Baghouse Filter. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4.11-3 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 11-4 Baghouse Filter ww Th2. Click on the Solid Ops icon. The Solid Operations Palette appears. 3. Double-click the Baghouse Filter icon. The Baghouse Filter property view appears. 11.1.2 Design Tab The Design tab contains the following pages: • Connections • Parameters • User Variables • Notes Figure 11.1 Figure 11.2 Solid Ops icon Baghouse Filter icon11-4 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Solid Separation Operations 11-5 ww ThConnections Page On the Connections page, you can specify the name of the operation, as well as the feed, vapour product, and solid product streams. Parameters Page On the Parameters page, you must specify the following information: Figure 11.3 Figure 11.4 Parameter Description Configuration When you make a change to any of the parameters, the configuration changes to User Defined. Select Default to revert to the HYSYS defaults.11-5 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 11-6 Baghouse Filter ww ThUser Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. 11.1.3 Rating Tab The Rating tab consists of the Sizing page. Sizing Page On the Sizing page, the following parameters can be specified: Clean Bag Pressure Drop The pressure drop across a clean bag. Dirty Bag Pressure Drop The pressure drop across a dirty bag. This value must be greater than the Clean Bag Pressure Drop. Figure 11.5 Parameter Description For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.11-6 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Solid Separation Operations 11-7 ww Th11.1.4 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. 11.1.5 Performance Tab The Performance tab consists of the Results page. Results page The following Filtration results appear on this page: • Filtration Time • Number of Cells • Area/Cell • Total Cell Area • Particle Diameter Parameter Description Maximum Gas Velocity Maximum velocity of gas in the Baghouse Filter. Bag Filter Area Filter Area for each bag. Bag Diameter Bag Diameter. Bags per Cell Number of bags per filter cell. Bag Spacing Spacing between the bags. Figure 11.6 Refer to Section 1.3.10 - Worksheet Tab for more information.11-7 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 11-8 Cyclone ww Th11.1.6 Dynamics Tab This unit operation is currently not available for dynamic simulation. 11.2 Cyclone The Cyclone is used to separate solids from a gas stream and is recommended only for particle sizes greater than 5 microns. The Cyclone consists of a vertical cylinder with a conical bottom, a rectangular inlet near the top, and an outlet for solids at the bottom of the cone. It is the centrifugal force developed in the vortex which moves the particles toward the wall. Particles which reach the wall, slide down the cone, and so become separated from the gas stream. The solids being separated must be previously specified and installed as components in the stream attached to this operation. 11.2.1 Cyclone Property View There are two ways that you can add a Cyclone to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Solids Handling radio button. 3. From the list of available unit operations, select Cyclone. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4.11-8 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Solid Separation Operations 11-9 ww Th2. Click on the Solid Ops icon. The Solid Operations Palette appears. 3. Double-click the Cyclone icon. The Cyclone property view appears. 11.2.2 Design Tab The Design tab contains the following pages: • Connections • Parameters • Solids • User Variables • Notes Figure 11.7 Figure 11.8 Solid Ops icon Cyclone icon11-9 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 11-10 Cyclone ww ThConnections Page You can specify the name of the operation, as well as the feed, vapour product, and solid product streams on the Connections page. Parameters Page On the Parameters page, you can specify the following parameters: Figure 11.9 Figure 11.1011-10 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Solid Separation Operations 11-11 ww ThThe diameter provided, either from the selected component or from the particle characteristics, is used in the efficiency calculations. For example, if you select an 85% efficiency, 85% of the solids of the specified diameter is recovered. All other solids in the inlet stream are removed at an efficiency related to these parameters. Solids Page You can specify the solid characteristics on the Solids page. This page contains two different data, depending on the radio button you selected in the Efficiency Basis group. Parameter Description Configuration Select either High Efficiency, High Output or User Defined. Efficiency Method Select either the Lapple or the Leith/Licht method. The latter is a more rigorous calculation as it considers radial mixing effects. Particle Efficiency The percent recovery of the specified solid in the bottoms stream. Figure 11.1111-11 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 11-12 Cyclone ww ThWhen you select the Single Particle Diameter radio button, the following solids information can be specified: When you select the Particle Size Distribution radio button, the following solids information can be specified: User Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. 11.2.3 Rating tab The Rating tab contains the following pages: • Sizing • Constraints Parameter Description Solid Name You must provide either the name of a solid already installed in the case, or provide a particle diameter and density. Particle Diameter and Particle Density If you do not choose a solid component, provide the particle diameter and density. Parameter Description Solid Name You must provide either the name of a solid already installed in the case, or provide a particle diameter and density. Particle Density If you do not choose a solid component, provide the particle density. Particle Size Distribution If you do not choose a solid component, provide the minimum or maximum particle size. For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.11-12 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Solid Separation Operations 11-13 ww ThSizing Page The Sizing page contains two groups: • Design Mode. Contains two radio buttons: On and Off. The radio buttons enables you to toggle between turning on or turning off the Design Mode option. When you select the Off radio button, the Specify Number of Parallel Cyclones checkbox appears in the Sizing page. Select the checkbox if you want to specify the number of parallel Cyclones in the flowsheet. • Sizing Ratios. Contains a table. The table below describes the parameters available on the page: Figure 11.12 Parameter Description Configuration Select High Output, High Efficiency, or User Defined. This is also defined on the Parameters page. Inlet Width Ratio The ratio of the inlet width to the body diameter (must be between 0 and 1). The value must be less than the Total Height Ratio Inlet Height Ratio The ratio of the inlet height to the body diameter. Cyclone Height Ratio The ratio of the Cyclone height to the body diameter. The Cyclone is the conical section at the bottom of the entire operation. Gas Outlet Length Ratio The ratio of the gas outlet length to the body diameter. Gas Outlet Diameter Ratio The ratio of the gas outlet diameter to the body diameter (must be between 0 and 1). The value must be less than the Total Height Ratio11-13 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 11-14 Cyclone ww ThConstraints Page On the Constraints page, you can specify the minimum and maximum diameter for the Cyclone. The page is also applicable only when the On radio button is selected in the Design Mode group. The Maximum Pressure Drop and Maximum Number of Cyclones is set on this page. These are used in the calculations to determine the minimum number of Cyclones needed to complete the separation. Total Height Ratio The ratio of the total height of the apparatus to the body diameter. Solids Outlet Diameter Ratio The ratio of the solids outlet diameter to the body diameter. Body Diameter If Design Mode is on, this is automatically calculated, within the provided constraints. If Design Mode is off, then you can specify this value. # Parallel Cyclones If Design Mode is on, this field displays the number of parallel Cyclones (if any) attached to the unit operation. If Design Mode is off and the Specify Number of Parallel Cyclones checkbox is selected, you can specify this value. Figure 11.13 Parameter Description11-14 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Solid Separation Operations 11-15 ww Th11.2.4 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. 11.2.5 Performance Tab The Performance tab contains the Results page. Results Page The Results page displays the calculated pressure drop, overall efficiency, and the number of parallel Cyclones. 11.2.6 Dynamics Tab This unit operation is currently not available for dynamic simulation. Figure 11.14 Refer to Section 1.3.10 - Worksheet Tab for more information.11-15 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 11-16 Hydrocyclone ww Th11.3 Hydrocyclone The Hydrocyclone is essentially the same as the cyclone, the primary difference being that this operation separates the solid from a liquid phase, rather than a gas phase. The solids being separated must be previously specified and installed as components in the stream attached to this operation. 11.3.1 Hydrocyclone Property View There are two ways that you can add a Hydrocyclone to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitsOps property view by pressing F12. 2. Click the Solids Handling radio button. 3. From the list of available unit operations, select Hydrocyclone. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4.11-16 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Solid Separation Operations 11-17 ww Th2. Click on the Solid Ops icon. The Solid Operations Palette appears. 3. Double-click the Hydrocyclone icon. The Hydrocyclone property view appears. 11.3.2 Design Tab The Design tab contains the following pages: • Connections • Parameters • Solids • User Variables • Notes Figure 11.15 Figure 11.16 Solid Ops icon Hydrocyclone icon11-17 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 11-18 Hydrocyclone ww ThConnections Page On the Connections page, you can specify the name of the operation, as well as the feed, liquid product, and solid product streams. Parameters Page On the Parameters page, you can specify the following parameters: Figure 11.17 Parameter Description Configuration Select either Mode 1, Mode 2 or User Defined. Particle Efficiency The percent recovery of the specified solid in the bottoms stream. Figure 11.1811-18 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Solid Separation Operations 11-19 ww ThThe diameter provided, either from the selected component or from the particle characteristics, is used in the efficiency calculations. For example, if you select an 85% efficiency, 85% of the solids of the specified diameter are recovered. All other solids in the inlet stream are removed at an efficiency related to these parameters. Solids Page On the Solids page, the following solids information can be specified: User Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. Parameter Description Solid Name You must provide either the name of a solid already installed in the case, or provide a particle diameter and density. Particle Diameter and Particle Density If you do not specify a Solid Name, provide the particle diameter and density. Figure 11.19 For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.11-19 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 11-20 Hydrocyclone ww Th11.3.3 Rating tab The Rating tab contains the following pages: • Sizing • Constraints Sizing Page The Sizing page contains two groups: • Design Mode. Contains two radio buttons: On and Off. The radio buttons enable you to toggle between turning on or turning off the Design Mode option. • Sizing Ratio. Contains a table. The table below describes the parameters available on the page: Figure 11.20 Parameter Description Configuration Select Mode 1, Mode 2 or User Defined. This is also defined on the Parameters page. Inlet Diameter Ratio The ratio of the inlet diameter to the body diameter. Included Angle (Degrees) The angle of the cyclone slope to the vertical. Overflow Length Ratio The ratio of the overflow length to the body diameter. Overflow Diameter Ratio The ratio of the overflow diameter to the body diameter. Total Height Ratio The ratio of the total height of the apparatus to the body diameter.11-20 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Solid Separation Operations 11-21 ww ThConstraints Page You can specify the minimum and maximum diameter for the Cyclone, applicable only when the On radio button is selected in the Design Mode group. The Maximum Pressure Drop and Maximum Number of Cyclones can also be set on this page. 11.3.4 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. Underflow Diameter Ratio The ratio of the underflow diameter to the body diameter. Body Diameter If Design Mode is on, then this is automatically calculated, within the provided constraints. If Design Mode is off, then you can specify this value. Figure 11.21 Parameter Description Refer to Section 1.3.10 - Worksheet Tab for more information.11-21 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 11-22 Rotary Vacuum Filter ww Th11.3.5 Performance Tab The Performance tab consists of the Results page. Results Page The calculated pressure drop, overall efficiency, and the number of parallel cyclones appear on this page. 11.3.6 Dynamics Tab This unit operation is currently not available for dynamic simulation. 11.4 Rotary Vacuum Filter The Rotary Vacuum Filter assumes that there is 100% removal of the solid from the solvent stream. This operation determines the retention of solvent in the particle cake, based on the particle diameter and sphericity of your defined solid(s). The diameter and sphericity determines the capillary space in the cake and thus the solvent retention. The solids being separated must be previously specified and installed as components in the stream attached to this operation. Figure 11.2211-22 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Solid Separation Operations 11-23 ww Th11.4.1 Rotary Vacuum Filter Property View There are two ways that you can add a Rotary Vacuum Filter to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Solids Handling radio button. 3. From the list of available unit operations, select Rotary Vacuum Filter. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Click on the Solid Ops icon. The Solid Operations Palette appears. 3. Double-click the Rotary Vacuum Filter icon. Figure 11.23 Solid Ops icon Rotary Vacuum Filter icon11-23 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 11-24 Rotary Vacuum Filter ww ThThe Rotary Vacuum Filter property view appears. 11.4.2 Design Tab The Design tab contains the following pages: • Connections • Parameters • User Variables • Notes Figure 11.2411-24 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Solid Separation Operations 11-25 ww ThConnections Page On the Connections page, you can define the operation name, as well as the feed, liquid product, and solids product streams. Parameters Page The Rotary Vacuum Filter parameters are described in the table below: Figure 11.25 Figure 11.26 Parameter Description Cycle Time The complete time for a cycle (one complete revolution of the cylinder). Dewatering The portion of the cycle between the time the cake comes out of the liquid to the time it is scraped, expressed as a percentage of the overall cycle time.11-25 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 11-26 Rotary Vacuum Filter ww ThUser Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. 11.4.3 Rating tab The Rating tab contains the following pages: • Sizing • Cake Sizing Page You can specify the following filter size parameters: Submergence The percentage of the overall cycle for which the cake is submerged. Pressure Drop Pressure drop across the filter. Parameter Description Filter Radius The radius of the filter. This defines the circumference of the drum. Filter Width The horizontal filter dimension. Filter Area The area of the filter. Parameter Description For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.11-26 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Solid Separation Operations 11-27 ww ThCake Page The Cake page consists of two groups: • Cake Properties • Resistance You can define the cake properties in the Cake Properties group. Figure 11.27 Figure 11.28 Property Description Mass Fraction of Cake The final solid mass fraction. Thickness The thickness of the cake. Porosity The overall void space in the cake.11-27 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 11-28 Rotary Vacuum Filter ww ThYou can define the resistance or use a resistance equation in the Resistance group. Selecting the Use Resistance Equation checkbox, which allows HYSYS to calculate the resistance value based on the Filtration Resistance equation. The Filtration Resistance equation is as follows: where: a, s = constants dP = pressure drop 11.4.4 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. 11.4.5 Dynamics Tab This unit operation is currently not available for dynamic simulation. Irreducible Saturation The solvent retention at infinite pressure drop. Permeability If you do not provide a value, HYSYS calculates this from the sphericity and diameter of the solid. Resistance = a(dP)s (11.1) Property Description Refer to Section 1.3.10 - Worksheet Tab for more information.11-28 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Solid Separation Operations 11-29 ww Th11.5 Simple Solid Separator The Simple Solid Separator (Simple Filter) performs a non- equilibrium separation of a stream containing solids. This operation does not perform an energy balance, as the separation is based on your specified carry over of solids in the vapour and liquid streams, and liquid content in the solid product. It should be used when you have an existing operation with known carry over or entrainment in the product streams. The solids being separated must be previously specified and installed as components in the stream attached to this operation. 11.5.1 Simple Solid Separator Property View There are two ways that you can add a Simple Solid Separator to your simulation: 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Solids Handling radio button. 3. From the list of available unit operations, select Simple Solid Separator. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4.11-29 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 11-30 Simple Solid Separator ww Th2. Click on the Solid Ops icon. The Solid Operations Palette appears. 3. Double-click the Simple Solid Separator icon. The Simple Solid Separator property view appears. 11.5.2 Design Tab The Design tab contains the following pages: • Connections • Parameters • Splits • User Variables • Notes Figure 11.29 Figure 11.30 Solid Ops icon Simple Solid Separator icon11-30 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Solid Separation Operations 11-31 ww ThConnections Page You can specify the name of the operation, feed stream, and product streams (Vapour, Liquid, Solids) on the Connections page. Parameters Page You can specify the pressure drop on the Parameters page. Figure 11.31 Figure 11.3211-31 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 11-32 Simple Solid Separator ww ThSplits Page On the Splits page, you must choose the split method by defining a Type of Fraction. The types of fraction are described in the table below. In the flowsheet, the streams are not reported as single phase, due to the solid content in the vapour and liquid streams, and the liquid content in the solid product stream. User Variables Page The User Variables page enables you to create and implement your own user variables for the current operation. Figure 11.33 Object Definition Split Fractions Specify the fractional distribution of solids from the feed into the vapour and liquid product streams. The solids fraction in the bottoms are calculated by HYSYS. You must also specify the fraction of liquid in the bottoms (solid product). Stream Fractions Enter the mole, mass or liquid volume fraction specification for each of the following: • Total vapour product solids fraction on the specified basis. • Total liquid product solids fraction on the specified basis. • Liquid phase fraction in the bottom product. For more information refer to Section 1.3.8 - User Variables Page/ Tab.11-32 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Solid Separation Operations 11-33 ww ThNotes Page The Notes page provides a text editor where you can record any comments or information regarding the specific unit operation, or your simulation case in general. 11.5.3 Rating Tab This unit operation currently does not have rating features. 11.5.4 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. 11.5.5 Dynamics Tab This unit operation is currently not available for dynamic simulation. For more information, refer to Section 1.3.5 - Notes Page/Tab. Refer to Section 1.3.10 - Worksheet Tab for more information.11-33 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 11-34 Simple Solid Separator ww Th11-34 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Streams 12-1 ww Th12 Streams12-1 12.1 Energy Stream Property View ...................................................... 2 12.1.1 Stream Tab............................................................................ 3 12.1.2 Unit Ops Tab .......................................................................... 3 12.1.3 Dynamics Tab ........................................................................ 4 12.1.4 Stripchart Tab ........................................................................ 4 12.1.5 User Variables Tab .................................................................. 4 12.2 Material Stream Property View .................................................... 5 12.2.1 Worksheet Tab ....................................................................... 8 12.2.2 Attachments Tab .................................................................. 30 12.2.3 Dynamics Tab ...................................................................... 33 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 12-2 Energy Stream Property View ww Th12.1 Energy Stream Property View Energy streams are used to simulate the energy travelling in and out of the simulation boundaries and passing between unit operations. 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing the F4 hot key. 2. Double-click the Energy Stream icon. The Energy Stream property view appears. The Energy Stream property view contains the following tabs that allow you to define stream parameters, view objects to which the stream is attached, and specify dynamic information: • Streams • Unit Ops • Dynamics • Stripchart • User Variables As with the material streams, the energy stream property view has the View Upstream Operation icon and the View Downstream Operation icon that allow you to view the unit operation to which the stream is connected. Energy streams Figure 12.1 Energy Stream icon View Upstream Operation icon View Downstream Operation icon12-2 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Streams 12-3 ww Thdiffer from material streams in that if there is no upstream or downstream connection on the stream (which is often the case for the energy stream) the associated icon is not active. 12.1.1 Stream Tab The Stream tab allows you to specify the Stream Name and Heat Flow for the stream. The figure below shows the Stream tab of the Energy Stream property view. 12.1.2 Unit Ops Tab The Unit Ops tab displays the Names and Types of all objects to which the energy stream is attached. Both unit operations and logicals are listed. The Unit Ops tab either shows a unit operation in the Product From cell or in the Figure 12.2 When converting an energy stream to a material stream, all material stream properties are unspecified, except for the stream name. Figure 12.312-3 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 12-4 Energy Stream Property View ww ThFeed To cell, depending on whether the energy stream receives or provides energy respectively. 12.1.3 Dynamics Tab The options on the Dynamics tab allow you to set the dynamic specifications for a simulation in dynamic mode. In dynamic mode, two different heating methods can be chosen for an energy stream. When the Direct Q radio button is selected, you can specify a duty value. When the Utility Fluid radio button is selected, the duty is calculated from specified properties of a utility fluid. The Utility Valve button opens the Flow Control Valve (FCV) view for the energy stream. 12.1.4 Stripchart Tab The Stripchart tab currently does not have any functions. 12.1.5 User Variables Tab The User Variables tab enables you to create and implement your own user variables for all energy streams. You can double-click on either the Product From or Feed To cell to access the property view of the operation attached to the stream. Figure 12.4 For a detailed description of the Direct Q and Utility Fluid Heating methods, refer to Section 6.7 - Valve. For more information refer to Section 1.3.8 - User Variables Page/ Tab.12-4 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Streams 12-5 ww Th12.2 Material Stream Property View Material streams are used to simulate the material travelling in and out of the simulation boundaries and passing between unit operations. For the material stream you must define their properties and composition so HYSYS can solve the stream. There are three methods to add a Material stream: 1. Select Flowsheet | Add Stream command from the menu bar. OR 1. Pres the F11 hot key. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing the F4 hot key. 2. Double-click the Material Stream icon. Material Stream icon12-5 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 12-6 Material Stream Property View ww ThThe Material Stream property view appears. The Material Stream property view contains three tabs and associated pages that allow you to define parameters, view properties, add utilities, and specify dynamic information. If you want to copy properties or compositions from existing streams within the flowsheet, click the Define from Other Stream button. The Spec Stream As Property View appears, which allows you to select the stream properties and/or compositions you want to copy to your stream. The left green arrow is the View Upstream Operation icon, which indicates the upstream position. The right green arrow is the View Downstream Operation icon, which indicates the downstream position. If the stream you want is attached to an operation, clicking these icons opens the property view of the nearest upstream or downstream operation. If the stream is not connected to an operation at the upstream or downstream end, then these icons open a Feeder Block or a Product Block. Figure 12.5 View Upstream Operation icon View Downstream Operation icon12-6 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Streams 12-7 ww ThSpec Stream As Property View The Spec Stream As property view enables you to select properties/information from other streams and use that information to define a stream. • The Available Streams list enables you to select the stream containing the properties you want to copy. You can only select one stream. • In defining the basic stream properties, you can only select the checkboxes of two of the following stream properties for the new stream: vapour fraction, temperature, pressure, molar enthalpy, or molar entropy. • The Composition checkbox enables you to copy the composition fraction values of the selected stream into the new stream. • The Correlations checkbox enables you to copy the selected stream’s correlation configuration into the new stream. • The Flow checkbox enables you to copy the selected stream’s flow rate value into the new stream. You can select the flow rate basis you want to copy into the new stream by selecting the appropriate radio button on the Flow Basis group. • The Cost Parameters checkbox enables you to copy the cost parameters values of the selected stream into the new stream. Figure 12.612-7 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 12-8 Material Stream Property View ww Th• The Cancel button enables you to exit the property view without accepting any changes. • The OK button enables you to exit the property view and accepts any changes made. 12.2.1 Worksheet Tab The Worksheet tab has pages that display information relating to the stream properties: • Conditions • Properties • Compositions • K Value • Electrolytes • User Variables • Notes The figure below shows the Worksheet tab of a solved material stream within a simulation. The Electrolytes page is only available if the stream is in an electrolyte system. Figure 12.7 The green status bar containing OK indicates a completely solved stream.12-8 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Streams 12-9 ww ThConditions Page The Conditions page displays all of the default stream information as it is shown on the Material Streams tab of the Workbook property view. The names and current values for the following parameters appear below: • Stream Name • Vapour/Phase Fraction • Temperature • Pressure • Molar Flow • Mass Flow • Std Ideal LiqVol Flow • Molar Enthalpy • Molar Entropy • Heat Flow • LiqVol Flow @ Std Cond • Fluid Package HYSYS uses degrees of freedom in combination with built-in intelligence to automatically perform flash calculations. In order for a stream to “flash”, the following information must be specified, either from your specifications or as a result of other flowsheet calculations: • Stream Composition Two of the following properties must also be specified; at least one of the specifications must be temperature or pressure: • Temperature • Pressure • Vapour Fraction In the electrolyte system, the Conditions page contains an extra column. This column displays the property parameters of the stream after electrolyte flash calculations. At least one of the temperature or pressure properties must be specified for the material stream to solve.12-9 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 12-10 Material Stream Property View ww Th• Entropy • Enthalpy Depending on which of the state variables are known, HYSYS automatically performs the correct flash calculation. Once a stream has flashed, all other properties about the stream are calculated as well. You can examine these properties through the additional pages of the property view. A flowrate is required to calculate the Heat Flow. The stream parameters can be specified on the Conditions page or in the Workbook property view. Changes in one area are reflected throughout the flowsheet. While the Workbook displays the bulk conditions of the stream, the Conditions page, Properties page, and Compositions page also show the values for the individual phase conditions. HYSYS can display up to five different phases. • Overall • Vapour • Liquid. If there is only one hydrocarbon liquid phase, that phase is referred to as liquid. • Liquid 1. This phase refers to the lighter liquid phase. • Liquid 2. This phase refers to the heavier liquid phase. In the electrolyte system, the entropy (S) is always a calculated property. If you specify a vapour fraction of 0 or 1, the stream is assumed to be at the bubble point or dew point, respectively. You can also specify vapour fractions between 0 and 1. For an electrolyte material stream, HYSYS conducts a simultaneous phase and reaction equilibrium flash on the stream. For the reactions involved in the flash and the model used for the flash calculation, refer to Section 1.6.9 - Electrolyte Stream Flash in the HYSYS OLI Interface Reference Guide.12-10 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Streams 12-11 ww Th• Aqueous. In the absence of an aqueous phase, the heavier hydrocarbon liquid is treated as aqueous. When there is only one aqueous phase, that phase is labelled as aqueous. • Mixed Liquid. This phase combines the Liquid phases of all components in a specified stream, and calculates all liquid phase properties for the resulting fluid. For example, if you expand the width of the default material stream property view (as shown in the figure below), you can view the hidden phase properties. In HYSYS, the liquid phase, and aqueous phase are internally recognized as Liquid 1, and Liquid 2, respectively. Liquid 1 refers to the lighter phase whereas the heavier phase is recognized as Liquid 2. If there is only one hydrocarbon liquid phase, that phase is referred to as liquid. The Mixed Liquid phase does not add its composition or molar flow to the stream it is derived from. This phase is only another representation of existing liquid components. Figure 12.812-11 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 12-12 Material Stream Property View ww ThIn this case, the vapour phase and liquid phase properties appear beside the overall stream properties. If there were another liquid phase, it would appear as well. Dynamic Mode In Dynamic mode, the Manipulate Conditions button appears on the Conditions page of the Material Stream property view. The Manipulate Conditions button allows you to change the values in a stream if you want to provide a different set of values for when the integrator is started. Normally, you would not have to use this feature. The Manipulate Conditions button is an advanced troubleshooting feature that you can use when you encounter problems, and you want to change the stream values temporarily to affect a downstream operation. You can use this feature, for example, if you ran the simulation and you got really cold temperatures out of a heat exchanger that is causing problems downstream. If you click the Manipulate Conditions button, the stream values in the table appear in red. You can then enter in a new temperature (even if the stream had no specifications before). The Manipulate Conditions button is also replaced by the Accept Stream Conditions button. Rather than expanding the property view, you can use the horizontal scroll bar to view the hidden phase properties. When you are viewing a stream property view in the column subflowsheet, there is an additional Create Column Stream Spec button on the Conditions page. This feature can be used on streams that feed into the flowsheet (sits on the boundary) and those that connect operations together. If the stream being changed flows out of a unit operation, its contents are likely overwritten by the upstream operation as soon as you start the integrator. If the downstream operation is new or had problems solving, changing its feed stream may allow HYSYS to solve the downstream operation or initialize and solve a replacement unit operation. For more information on the functionality of the Create Column Stream Spec button, refer to Section 2.6 - Column Stream Specifications.12-12 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Streams 12-13 ww ThIf you click the Accept Stream Conditions button, HYSYS performs flash calculations again with the initial values you provided. The stream values in the table appear in black as before. Properties Page The Properties page displays the properties for each stream phase. The options in the Property Correlation Controls group enables you to manipulate the property correlations displayed on this page for an individual stream. By default the properties from the Conditions page are not available on this page. The Properties page contains a table, a Preference Option display field, and a group of icons. • The table displays the property correlations you select for the stream. • The Preference Option display field is Active if the Activate Property Correlations checkbox is selected. This checkbox can be found on the Options page, Simulation tab of the Session Preferences property view. You can also manipulate the property correlations displayed in the Properties page using the Correlation Manager. Figure 12.9 Refer to Section 11.18 - Correlation Manager in the HYSYS User Guide for more information.12-13 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 12-14 Material Stream Property View ww Th• The Property Correlation Controls group contains ten icons. These icons are used to manipulate the property correlations displayed in the table. You can modify and over-write any existing correlation set using the stream’s Property Correlation Controls. Name Icon Description View Correlation Set List Allows you to select a correlation set. Append New Correlation Allows you to add a property correlation to the end of the table. Move Selected Correlation Down Allows you to move the selected property correlation one row down the table. Move Selected Correlation Up Allows you to move the selected property correlation one row up the table. Sort Ascending Allows you to sort the property correlations in the table by ascending alphabetic order. Remove Selected Correlation Allows you to remove the selected property correlation from the table. Remove All Correlations Allows you to remove all the property correlations from the table. Save Correlation Set to File Allows you to save a set of property correlations. View Selected Correlation Allows you to view the parameters and status of the selected property correlation. View All Correlation Plots Allows you to view all correlation plots for the selected stream. Refer to Displaying a Correlation Set section for more information. Refer to Adding a Property Correlation section for more information. Refer to Removing a Property Correlation from the table section for more information. Refer to Creating a Correlation Set section for more information. Refer to Viewing a Property Correlation section for more information. Refer to Viewing All Correlation Plots section for more information.12-14 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Streams 12-15 ww ThAdding a Property Correlation To add a property correlation to the table: 1. Click the Append New Correlation icon. The Correlation Picker property view appears. 2. Select a property correlation that you want to view from the branch list. Click the Plus icon to expand the available correlations list. 3. Click the Apply button to append the selected property correlation to the stream. If the selected correlation cannot be calculated by that stream’s fluid, a message will be sent to the trace window informing the user that this property correlation cannot be added to the stream. 4. Repeat steps #2 to #3 to add another property correlation. 5. When you have completed appending property correlations to the stream, click the Close button to return to the stream property view. To select a different stream to append the property correlations to: 1. Click the Select Material Stream to Append icon. The Select Material Stream property view appears. 2. Select the appropriate stream from the object list. Figure 12.10 Append New Correlation icon HYSYS property correlations have been grouped into categories which target the specific reporting needs of the various process industries. This display field shows the name of the stream the property correlation will be appended to. Select Material Stream to Append icon12-15 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 12-16 Material Stream Property View ww Th3. Click the OK button to return to the Correlation Picker property view. You can now add a property correlation to the selected stream. The new selected stream’s name also appears in the display field located beside the Select Material Stream to Append icon. Removing a Property Correlation from the table To remove property correlations from the table: 1. Select the property correlation you want to remove in the table. 2. Click the Remove Selected Correlation icon. HYSYS removes the selected property correlation from the table. You can remove all property correlations in the table by clicking the Remove All Correlations icon. Creating a Correlation Set To save the property correlations in the table as a set: 1. Add all the property correlations you want to the table. 2. Click the Save Correlation Set to File icon. The Save Correlation Set Name property view appears. HYSYS automatically enters a name for the property list based on the stream name. 3. Enter the name you want for the property list in the Set Name (Global) field. Each correlation set name must be unique. Figure 12.11 Remove Selected Correlation icon Remove All Correlations icon Save Correlation Set to File icon For example, the stream called AGO, HYSYS automatically enters the default name AGO- CorrelationSet for the property list.12-16 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Streams 12-17 ww Th4. Click the Save button to save the property list. The saved correlation set can then be added to other streams using the View Correlation Set List icon displayed in each stream property view. You can also add the saved correlation set to all of the streams within the case by using the Correlation Manager. Displaying a Correlation Set To display a correlation set: 1. Click the View Correlation Set List icon. 2. The Correlation Set Picker property view appears. 3. Select the correlation set you want from the property view. If you are creating a correlation set for the first time, you are also creating the default file (Support\StreamCorrSets.xml) which will hold all these sets. You can change the name of the file on the Locations page, Files tab of the Session Preferences property view. Figure 12.12 If the xml file does not exist (you have never created a correlation set before) the window will display “File has not been created.” If the xml file does exist but all previous sets have been deleted, the window will display “File is empty.” View Correlation Set List icon View Correlation Set List icon The location and name of the file that contains the correlation set is shown in the File Path field. The xml path and file name can be changed using the Session Preferences property view. Refer to Section 12.5.2 - Locations Page from the HYSYS User Guide.12-17 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 12-18 Material Stream Property View ww ThTo see the list of correlations contained within the correlation set, click the associate Plue icon . 4. Click the Apply button. The Correlation Set Picker property view will close, and the property correlations contained in the selected correlation set will appear in that streams properties table. 5. Repeat steps #1 to #4 to apply additional correlation sets to your stream. You can expand the property view or use the scroll bar to view any property correlation phase values, as shown in the figure below. HYSYS will check each correlation’s type against the fluid type of the stream. If a problem occur while appending a correlation from the set, a warning will be sent to the Trace window. Figure 12.13 Refer to Section 1.3 - Object Status & Trace Windows in the HYSYS User Guide, for more information on Trace window.12-18 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Streams 12-19 ww ThDeleting a Correlation Set To delete a correlation set: 1. Click the View Correlation Set List icon. 2. The Correlation Set Picker property view appears. 3. Select the correlation set you want to delete. 4. Click the Delete button. A window will appear asking you if you are sure you want to delete the set because it cannot be undone. 5. Click the Yes button and the Correlation Set Picker property view appears with the chosen set deleted from the list. 6. Click the Close icon to close the Correlation Set Picker property view and return to the stream property view. Figure 12.14 View Correlation Set List icon12-19 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 12-20 Material Stream Property View ww ThViewing a Property Correlation When you select a property correlation from the table and click the View Selected Correlation icon, the following property view appears. The following table describes the status bars contained in the Status group. Figure 12.15 The values shown on the correlation property view cannot be edited. Any configuration parameters available to each property correlation can only be edited using the Correlation Manager property view. Status Bar Description Stream Indicates that the correlation can only be applied to material streams. Point/Plottable Indicates whether the property correlation is a point or plottable property. Black Oil/ Electrolyte/Gas/ Petroleum/RFG/ RVP/Solid/ Standard/User/ Clone Indicates which correlation type the property correlation resides within in the Available Correlations list. View Selected Correlation icon12-20 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Streams 12-21 ww ThIn the Parameters group, you can view the parameters used to calculate the property correlation. In the Stream Connections group, a list of all the material streams currently using the property correlation is displayed. Viewing All Correlation Plots The View All Correlation Plots icon opens the Correlation Plots property view which displays all plottable properties for the stream. Active/Inactive Indicates whether the property correlation has been activated by the correlation manager. If the status bar is green, any new stream added to the flowsheet with the same fluid type as the correlation will automatically have the property correlation added. In Use/Not in Use Indicates whether the property correlation is being used by a stream in the case. Available/ Unavailable Indicates whether the property correlation exists in the window registry of the system. To manipulate the parameter values, you have to access the Correlation Manager property view. Figure 12.16 Status Bar Description Refer to Section 11.18 - Correlation Manager in the HYSYS User Guide for more information. View All Correlation Plots icon12-21 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 12-22 Material Stream Property View ww ThOnly plottable properties appear on the plots property view, while both point and plot properties appear on the stream properties property view. The plot property view can show only one plot property at a time. Composition Page The Composition page enables you to specify and manipulate the stream composition. To specify or change the stream composition do one of the following: • Click the Edit button. The Input Composition property view appears. • Type a value in a component cell and press ENTER. The Input Composition property view appears. Blue or red colour text indicates the composition of streams is changeable. You cannot edit the compositions for a stream that is calculated by HYSYS. If the composition is calculated by HYSYS, the text colour of the composition value is black and the Edit button will be greyed out. A warning appears if negative mole fraction values occur. Refer to Input Composition Property View section for more information.12-22 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Streams 12-23 ww ThThe figure below shows the mole fractions for each component in the overall phase, vapour phase, and aqueous phase. You can view the composition in a different basis by clicking the Basis button, and selecting the basis you want on the Stream property view. Stream Property View The Stream property view contains several radio buttons. The basis type available in HYSYS is represented by each radio button. Figure 12.17 Figure 12.1812-23 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 12-24 Material Stream Property View ww ThTo choose a basis: 1. In the Stream property view, click one of the radio buttons to select a compositional basis. 2. Click the Close icon to return to the Composition page. HYSYS displays the stream compositions using the selected basis. Input Composition Property View The Input Composition property view allows you to edit the stream compositions. In the Composition Basis group, select the radio button that corresponds to the basis for your stream. In the list of available components, specify the composition of the stream. Figure 12.1912-24 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Streams 12-25 ww ThThe Composition Controls group has two buttons that can be used to manipulate the compositions. The OK button closes the Input Composition property view and accepts any specified changes to the stream composition. The Cancel button closes the property view without accepting any changes. Button Action Erase Clears all compositions. Normalize Allows you to enter any value for fractional compositions and have HYSYS normalize the values such that the total equals 1. This button is useful when many components are available, but you want to specify compositions for only a few. When you enter the compositions, click the Normalize button and HYSYS ensures the Total is 1.0, while also specifying any compositions as zero. If compositions are left as , HYSYS cannot perform the flash calculation on the stream. The Normalize button does not apply to flow compositional bases, since there is no restriction on the total flowrate. For fractional bases, clicking the OK button automatically normalizes the composition if all compositions contain a value.12-25 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 12-26 Material Stream Property View ww ThK Value Page The K Value page displays the K values or distribution coefficients for each component in the stream. A distribution coefficient is a ratio between the mole fraction of component i in the vapour phase and the mole fraction of component i in the liquid phase: where: Ki = distribution coefficient yi = mole fraction of component i in the vapour phase xi = mole fraction of component i in the liquid phase Figure 12.20 (12.1)Ki yi xi ---=12-26 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Streams 12-27 ww ThElectrolytes Page If the stream is associated with an OLI-Electrolyte property package, the Electrolytes page displays electrolytic information. You can view the electrolyte stream properties or the electrolyte stream composition for aqueous or solid phase. In the True Species Info group, select the appropriate radio button to view the electrolyte stream properties. The Properties radio button displays the stream fluid phase properties for an electrolyte system. Use the radio buttons in the Phase group to switch between the aqueous phase and the solid phase. When you click the Aqueous phase radio button, the following aqueous phase related properties appear: • pH value • Osmotic Pressure • Ionic Strength • Heat Capacity • Viscosity Figure 12.21 The Electrolytes page is available only if the stream is in an electrolyte system. Refer to Section 1.2.4 - Adding Electrolyte Components in the HYSYS Simulation Basis guide for more information on electrolytes. For more information, refer to Section 1.6 - HYSYS OLI_Electrolyte Property Package in the HYSYS OLI Interface Reference Guide.12-27 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 12-28 Material Stream Property View ww ThWhen you click the Solid phase radio button, you can include or exclude a particular solid in the current stream equilibrium flash calculation. The Composition radio button displays the component name, molar fraction, molar flow, or molality and molarity of all the components in the stream for aqueous or solid phase in a table. Figure 12.22 Figure 12.23 To globally include or exclude particular solids in all electrolyte streams, refer to OLI_Electrolyte Options section from Section 2.4.1 - Set Up Tab in the HYSYS Simulation Basis guide. The value of Scale Tendency Index as shown in the table is a measure of the tendency of a solid species forming at the specified conditions. Solid with a scaling tendency greater than one forms if the solid formation is governed by equilibrium (as opposed to kinetics), and if there are no other solids with a common cation or anion portion which also has a scaling tendency greater than one. If you select the Aqueous radio button, the component list including ionic component(s) appears in the table. If you select the Solid radio button, a component list including precipitate (PPT) and hydrated (-nH2O) solid appears with only mole fraction and mole flow.12-28 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Streams 12-29 ww ThUser Variables Page The User Variables page enables you to create and implement your own user variables for all material streams. Notes Page The Notes page provides a text editor that allows you to record any comments or information regarding the material stream or the simulation case in general. Cost Parameters Page You can enter a cost factor value for the stream in the Cost Parameters page. You can also choose the flow basis associated with the cost factor from the Flow Basis drop-down list. Figure 12.24 For more information refer to Section 1.3.8 - User Variables Page/ Tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.12-29 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 12-30 Material Stream Property View ww Th12.2.2 Attachments Tab Unit Ops Page The Unit Ops page allows you to view the names and types of unit operations and logicals to which the stream is attached. The property view uses three groups: • The units from which the stream is a product. • The units to which the stream is a feed. • The logicals to which the stream is connected. You can access the property view for a specific unit operation or logical by double-clicking in the Name cell or Type cell. Figure 12.2512-30 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Streams 12-31 ww ThUtilities Page The Utilities page allows you to view and manipulate the utilities attached to the stream. The Utilities page allows you to do the following: • Attach utilities to the current stream. • View existing utilities that are attached to the stream. • Delete existing utilities that are attached to the stream. Figure 12.26 Only the Create button is available all the time. The View and Delete buttons are greyed out until you select a utility from the list. Refer to Chapter 14 - Utilities for more information on the utilities available in HYSYS. Refer to Section 7.26 - Utilities in the HYSYS User Guide for more information on adding, viewing, and deleting utilities.12-31 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 12-32 Material Stream Property View ww ThDRU Stream Page The DRU stream facilitates running a given set of unit operations under different stream conditions. The information gathered from the run are stored within the DRU stream, and can be either user input or acquired from the RTO system directly. The DRU stream is used for data reconciliation to hold different states of streams. During data reconciliation, measured data of DCS tags can be obtained under different stream states (for example, temperature or pressure). The DRU stream can also perform flash calculations as other HYSYS streams do. If you want to use the DRU stream to hold data, the number of data sets needs to be equal to the number of data sets of DCS tags. You can create data sets for streams and set values to stream states. The Data Rec utility controls the updating of its associated streams with the correct data corresponding to the data set being evaluated at that point in time. Figure 12.27 The DRU stream is applicable for data reconciliation problems. Each data set behaves as a stream (for example, the data set contains automatic flash calculation and freedom control). When the Add Transfer Stream button is enabled, the Delete Transfer Stream button is disabled, and vice-versa.12-32 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Streams 12-33 ww ThThe Add Transfer Stream button and Delete Transfer Stream button are solely for On-Line applications. • Clicking the Add Transfer Stream button creates a DRU Stream (Data Reconciliation Stream) such that you can move the information for the stream as a block between HYSYS cases, or instances of HYSYS. • Clicking the Delete Transfer Stream button removes the DRU Stream. 12.2.3 Dynamics Tab The Dynamics tab displays the pressure and flow specifications for the material stream, and enables you to generate the strip chart for a set of variables. Specs Page The Specs page allows you to add a pressure and a flow specification for the stream. You must be in dynamic mode for any of these specifications to have an effect on the simulation. Figure 12.28 Feeder block or Product block button appears only when the stream is a flowsheet boundary stream.12-33 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 12-34 Material Stream Property View ww ThIf the Active checkbox is selected for a specification, the value of the specification appears in blue and you can modify the value. If the Active checkbox is cleared, the value is appears in black and is calculated by HYSYS. Default stream conditions are shown in red. Feed and Product Blocks A flowsheet boundary stream is a stream which has only one unit operation attached to it. If a material stream is a flowsheet boundary stream, a Feeder block button or Product block button appears in the Specs page of the Dynamics tab. A flowsheet boundary stream can be the feed or product of the model. Depending on whether the flowsheet boundary stream is a feed or a product, the Dynamics tab contains either a Feeder block button or a Product block button. The figure below shows a Product Block property view of a material stream. You can also access the Feeder Block property view by clicking the View Upstream Operation icon on the stream property view. Similarly, you can also access the Product Block property view by clicking the View Downstream Operation icon. Figure 12.29 To ignore the Feed or Product block operations, select the Ignored checkbox. View Upstream Operation icon View Downstream Operation icon12-34 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Streams 12-35 ww ThThe Product Block property view displays flow reversal conditions of the material stream which you can specify. If simulation conditions are such that the product stream flow becomes negative, HYSYS recalls the stream conditions stored in the Product block and performs a rigorous flash on the product stream to determine the other stream conditions. When process conditions in the simulation cause the feed flow to reverse, the feed stream conditions are calculated by the downstream operation. The Feeder Block property view is used to restore desired feed conditions and compositions if the feed stream reverses and then becomes feed again. The Feeder Block and Product Block have similar property views. You can specify the stream conditions as follows: Since the pressure of the stream remains the same after the product stream flow reverses, the pressure value does not need to be specified. With this information, the stream is able to perform flash calculations on the other stream properties. Both the Feeder Block property view and Product Block property view have three buttons that allow you to manipulate the direction of stream conditions between the material stream and the block. The table below briefly describes each button.: Required Feed and Product Block Specifications Conditions Tab Specify one of the following: • Temperature • Vapour Fraction • Entropy • Enthalpy Composition Tab Specify the stream composition. Block Button Action Export Conditions to Stream Copies stream conditions stored in the block to the material stream. Update From Stream Copies the current stream conditions from the material stream to the block. Update from Current Composition Copies only the stream composition from the material stream to the block.12-35 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 12-36 Material Stream Property View ww ThStripchart Page The Stripchart page allows you to select and create default strip charts containing various variable associated to the material stream. Refer to Section 1.3.7 - Stripchart Page/Tab for more information.12-36 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Subflowsheet Operations 13-1 ww Th13 Subflowsheet Operations13-1 13.1 Introduction................................................................................. 2 13.2 Subflowsheet Property View ........................................................ 3 13.2.1 Adding a Subflowsheet ............................................................ 4 13.2.2 Connections Tab ..................................................................... 6 13.2.3 Parameters Tab ...................................................................... 8 13.2.4 Transfer Basis Tab................................................................... 9 13.2.5 Transition Tab ...................................................................... 10 13.2.6 Variables Tab ....................................................................... 14 13.2.7 Notes Tab ............................................................................ 15 13.2.8 Lock Tab.............................................................................. 16 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 13-2 Introduction ww Th13.1 Introduction The subflowsheet operation uses the multi-level flowsheet architecture and provides a flexible, intuitive method for building the simulation. Suppose you are simulating a large processing facility with a number of individual process units and instead of installing all process streams and unit operations into a single flowsheet, you can simulate each process unit inside its own compact subflowsheet. Once a subflowsheet operation is installed in a flowsheet, its property view becomes available just like any other flowsheet object. Think of this property view as the “outside” property view of the “black box” that represents the subflowsheet. Some of the information contained on this property view is the same as that used to construct a Template type of Main flowsheet. Naturally this is due to the fact that once a Template is installed into another flowsheet, it becomes a subflowsheet in that simulation. Whether the flowsheet is the Main flowsheet of a simulation case, or it is contained in a subflowsheet operation, it possesses the following components: • Fluid Package. An independent fluid package, consisting of a Property Package, Components, and so forth. It is not necessary that every flowsheet in the simulation have its own separate fluid package. More than one flowsheet can share the same fluid package. • Flowsheet Objects. The inter-connected topology of the flowsheet. Unit operations, material and energy streams, utilities, and so forth. • A Dedicated PFD. A HYSYS property view presenting a graphical representation of the flowsheet, showing the inter-connections between flowsheet objects. • A Dedicated Workbook. A HYSYS property view of tabular information describing the various types of flowsheet objects. • A Dedicated Desktop. The PFD and Workbook are home property views for this Desktop, but also included are a menu bar and a toolbar specific to either regular or Column subflowsheets.13-2 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Subflowsheet Operations 13-3 ww Th13.2 Subflowsheet Property View The Subflowsheet property view consists of the following tabs: • Connections • Parameters • Transfer Basis • Mapping • Variables • Notes • Lock Figure 13.1 Click this button to enter the subflowsheet environment.13-3 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 13-4 Subflowsheet Property View ww Th13.2.1 Adding a Subflowsheet There are two ways you can add a subflowsheet to your simulation. 1. Select Flowsheet | Add Operation command from the menu bar. The UnitOps property view appears. You can also access the UnitOps property view by pressing F12. 2. Click the Sub-Flowsheets radio button. 3. From the list of available unit operations, select Standard Sub-Flowsheet. 4. Click the Add button. OR 1. Select Flowsheet | Palette command from the menu bar. The Object Palette appears. You can also open the Object Palette by pressing F4. 2. Double-click on the Sub-Flowsheet icon on the Object Palette. The Sub-Flowsheet Option property view appears. The Sub-Flowsheet Option property view contains the following options: • Read an Existing Template • Start with a Blank Flowsheet • Paste exported objects • Cancel Figure 13.2 Sub-Flowsheet icon13-4 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Subflowsheet Operations 13-5 ww ThRead an Existing Template If you want to use a previously constructed Template that has been saved on disk, click the Read an Existing Template button on the Sub-Flowsheet Option property view. Start with a Blank Flowsheet If you want to start with a blank subflowsheet, click the Start with a Blank Flowsheet button on the Sub-Flowsheet Option property view, HYSYS will install a subflowsheet operation containing no unit operations or streams. On the Connections tab of the property view of the blank subflowsheet, there will be no feed or product connections (boundary streams) to the subflowsheet. You can connect feed streams in the External Stream column by either typing in the name of the stream to create a new stream or selecting a pre- defined stream from a drop-down list. When an external feed connection is made by selecting a pre-defined stream from the drop-down list, a stream similar to the pre-defined stream is created inside the subflowsheet environment. In order to fully define the flowsheet, you have to enter the subflowsheet environment. Click the Sub-Flowsheet Environment button on the property view to transition to the subflowsheet environment and its dedicated Desktop. The subflowsheet is constructed using the same methods as the main flowsheet. When you return to the Parent environment, you can connect the subflowsheet boundary streams to streams in the Parent flowsheet. Paste Exported Objects If you want to import previously exported objects into a new subflowsheet, click the Paste Exported Objects button on the Sub-Flowsheet Option property view. For more information, refer to Section 3.5.2 - Creating a Template Style Flowsheet in the HYSYS User Guide.13-5 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 13-6 Subflowsheet Property View ww ThYou copy and paste selected objects inside the same subflowsheet or another subflowsheet. You can also copy and paste subflowsheets and column subflowsheets. Objects can also be moved into or out of a subflowsheet. 13.2.2 Connections Tab You can enter the name of the subflowsheet, as well as its Tag name, on the Connections tab. All feed and product connections appear on the Connections tab. Flowsheet Tags These short names are used by HYSYS to identify the flowsheet associated with a stream or operation when that flowsheet object is being viewed outside of its native flowsheet scope. The default Tag name for a subflowsheet operation is TPL1 (for Template). The objects that are selected and exported via the PFD can be imported back into a flowsheet without creating a new subflowsheet first. Figure 13.313-6 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Subflowsheet Operations 13-7 ww ThWhen more than one subflowsheet operation is installed, HYSYS ensures unique tag names by incrementing the numerical suffix; the subflowsheets are numbered sequentially in the order they were installed. For example, if the first subflowsheet added to a simulation contained a stream called Comp Duty, it would appear as Comp Duty@TPL1 when viewed from the Main flowsheet of the simulation. Feed and Product Connections Internal streams are the boundary streams within the subflowsheet that can be connected to external streams in the Parent flowsheet. Internal streams cannot be specified on this tab, they are automatically determined by HYSYS. Basically, any streams in the subflowsheet that are not completely connected (in other words,”open ended”) can serve as a feed or product. To connect the subflowsheet, specify the appropriate name of the external streams, which are in the Parent flowsheet, in the matrix opposite the corresponding internal streams, which are in the subflowsheet. The stream conditions are passed across the flowsheet boundary via these connections. Subflowsheet streams that are not connected to any unit operations in the subflowsheet appear in the property view as well (and are termed “dangling streams”). Figure 13.4 It is not necessary to specify an external stream for each internal stream.13-7 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 13-8 Subflowsheet Property View ww Th13.2.3 Parameters Tab You can view the exported subflowsheet variables on the Parameters tab, which allows you to keep track of several key variables without entering the subflowsheet environment or adding the variables to the global DataBook. It is also useful when dealing with a subflowsheet as a black box. The user who created the subflowsheet can set up an appropriate Parameters tab, and another user of the subflowsheet can be unaware of the complexities within the subflowsheet. These variables display values, which have been calculated or specified by the user. If changes to the specified values are made here, the subflowsheet is updated accordingly. For each variable, the description, value, and units are shown. • The Ignore checkbox is used to bypass the subflowsheet during calculations, just as with all HYSYS unit operations. • The Update Outlets checkbox enables you to toggle between transferring or not transferring updated values from the subflowsheet to the external streams. Figure 13.5 These variables are actually added on the Variables Tab of the property view, but are viewed in full detail on the Parameters tab.13-8 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Subflowsheet Operations 13-9 ww Th13.2.4 Transfer Basis Tab The transfer basis for each Feed and Product Stream is listed on the Transfer Basis tab. The transfer basis only becomes significant when the subflowsheet and Parent flowsheet's fluid packages consist of different property methods. The transfer basis is used to provide a consistent means of switching between the different basis of the various property methods. The table below list all the possible transfer basis provided by HYSYS: Figure 13.6 The Transfer Basis is also useful in controlling VF, T, or P calculations in column subflowsheet boundary streams with close boiling or nearly pure compositions. Transfer Basis Description T-P Flash The Pressure and Temperature of the Material stream are passed between flowsheets. A new Vapour Fraction is calculated. VF-T Flash The Vapour Fraction and Temperature of the Material stream are passed between flowsheets. A new Pressure is calculated. VF-P Flash The Vapour Fraction and Pressure of the Material stream are passed between flowsheets. A new Temperature is calculated.13-9 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 13-10 Subflowsheet Property View ww Th13.2.5 Transition Tab The Transition tab allows you to select and modify the stream transfer and map methods for the fluid component composition across fluid package boundaries. You may choose between three transition types: FluidPkg Transition, Basis Transition, and Black Oil Transition. Fluid Package Transition Composition values for individual components from one fluid package can be mapped to a different component in an alternate fluid package. Mapping is especially useful when dealing with hypothetical oil components where like components from one fluid package can be mapped across the subflowsheet P-H Flash The Pressure and Enthalpy of the Material stream are passed between flowsheets. User Specs You define the properties passed between flowsheets for a Material stream. None Required No calculation is required for an Energy stream. The heat flow is simply passed between flowsheets. No transfer basis has been selected. Figure 13.7 Transfer Basis Description13-10 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Subflowsheet Operations 13-11 ww Thboundary to another fluid package. Basic Transition The Basic Transition view outlines the value of each component within the Inlet Stream Molar Composition and the Outlet Stream Molar Composition. Component Maps can also be created and edited in the Basis environment. Figure 13.8 Refer to Section 6.2 - Component Maps Tab in the HYSYS Simulation Basis guide for more information.13-11 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 13-12 Subflowsheet Property View ww ThBlack Oil Transition The Black Oil Transition view allows you to: • Choose between three sperarate Black Oil Transition Methods: - Simple - Three Phase - Infochem Mulitflash • Select the Oil Phase Cut Options from the drop-down list. • View/Edit the Composition of the stream. • Erase the Compostion of the stream. • Normalize the Composition of the stream. For every pairing of different fluid packages, a collection of maps exists. Component maps can be added to each collection on the Component Maps tab in the Simulation Basis Manager property view. To select a transfer and map method for the inlet and outlet streams: 1. In the approriate cell under the Transition column, click the Figure 13.913-12 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Subflowsheet Operations 13-13 ww Thdown arrow icon to open the drop-down list. 2. In the drop-down list, select the transition type you want to apply to the stream. 3. Repeat the above steps for all the streams that require a transition method. To modify the type of transfer and map method for inlet and outlet streams: 1. Under the Stream column, click on the cell containing the stream you want to modify. 2. Click the appropriate View Transition button in the group. The Transition property view of the selected stream appears. 3. In the Transition property view, you can make the following changes: • modify the fluid package of the streams • edit, add, or delete a component map method • modify the transfer basis 4. Click the Imbalance button to view the component imbalance in the selected stream. To view overall component imbalance for streams flowing through the subflowsheet: 1. Click the Overall Imbalance Into Sub-Flowsheet button Some of the transition method require the RefSYS or Upstream license to run. Figure 13.1013-13 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 13-14 Subflowsheet Property View ww Thor Overall Imbalance Out of Sub-Flowsheet button to open the Untransferred Component Info property view. The Untransferred Component Info property view allows you to confirm that all of the components have been transferred into or out of the subflowsheet. 2. Click the appropriate radio button to view the imbalance in molar, mass, or liquid volume basis. 13.2.6 Variables Tab The Variables tab of the Main flowsheet property view allows you to create and maintain the list of externally accessible variables. Although you can access any information inside the subflowsheet using the Variable Navigator, the features on the Variables tab allow you to target key process variables inside the subflowsheet and display their values on the property view. Then, you can conveniently view this whole group of information directly on the subflowsheet property view in the Parent flowsheet. To add variables: 1. Click the Add button. The Variable Navigator property view Figure 13.11 Refer to Section 1.3.9 - Variable Navigator Property View for information on the Variable Navigator.13-14 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Subflowsheet Operations 13-15 ww Thappears. 2. On the Variable Navigator property view, select the flowsheet object and variable you want. You can also over-ride the default variable description displayed in the Variable Description field of the Variable Navigator property view. 13.2.7 Notes Tab The Notes tab provides a text editor where you can record any comments or information regarding the material stream or to your simulation case in general. Any subflowsheet variables added in the Variables tab will appear on the Parameters tab. For more information, refer to Section 1.3.5 - Notes Page/Tab.13-15 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 13-16 Subflowsheet Property View ww Th13.2.8 Lock Tab The Lock tab enables you to lock or unlock the subflowsheet and displays the lock status of the subflowsheet. When the flowsheet is locked, you cannot create or delete objects, or change the topology. You can add Set, Adjust, and Spreadsheet operations; manipulate variable values; or copy the contents of the flowsheet and create your own modifiable version. • To lock a subflowsheet, enter a password in the Lock Status field and press ENTER. • To unlock a subflowsheet, enter the correct password in the Lock Status field and press ENTER. Figure 13.12 Subflowsheets inside a locked subflowsheet have to be specifically locked.13-16 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-1 ww Th14 Utilitiesw.cadfamily.com EMa e document is for study 14.1 Introduction................................................................................. 4 14.2 Boiling Point Curves..................................................................... 7 14.2.1 Design Tab ............................................................................ 8 14.2.2 Performance Tab .................................................................. 10 14.2.3 Dynamics Tab ...................................................................... 13 14.3 CO2 Solids.................................................................................. 14 14.3.1 Design Tab .......................................................................... 15 14.3.2 Dynamics Tab ...................................................................... 16 14.4 Cold Properties .......................................................................... 17 14.4.1 Design Tab .......................................................................... 18 14.4.2 Performance Tab .................................................................. 21 14.4.3 Dynamics Tab ...................................................................... 22 14.5 Composite Curves Utility ............................................................ 23 14.5.1 Design Tab .......................................................................... 23 14.5.2 Performance Tab .................................................................. 25 14.6 Critical Properties ...................................................................... 29 14.6.1 Design Tab .......................................................................... 31 14.6.2 Dynamics Tab ...................................................................... 32 14.7 Data Reconciliation Utility.......................................................... 33 14.7.1 Data Reconciliation Utility Property View .................................. 35 14.7.2 Optimization Objects............................................................. 48 14.7.3 DRU Diagnostic File Output .................................................... 53 14.8 Derivative Utility........................................................................ 5914-1 il:cadserv21@hotmail.com only,if tort to your rights,please inform us,we will delete 14-2 Utilities www.cadfamily.com EMa The document is for study 14.9 Dynamic Depressuring................................................................60 14.9.1 Design Tab ...........................................................................64 14.9.2 Worksheet Tab ......................................................................84 14.9.3 Performance Tab ...................................................................85 14.10 Envelope Utility ........................................................................87 14.10.1 HYSYS Two-Phase Envelope ..................................................87 14.10.2 Three-phase Envelope Utility.................................................94 14.11 FRI Tray Rating Utility ............................................................110 14.11.1 Inputs Tab ........................................................................111 14.11.2 Results Tab.......................................................................118 14.11.3 Tray Properties Tab ............................................................124 14.12 Hydrate Formation Utility .......................................................126 14.12.1 Design Tab .......................................................................134 14.12.2 Performance Tab ...............................................................137 14.12.3 Dynamics Tab ...................................................................140 14.13 Master Phase Envelope Utility.................................................142 14.13.1 Design Tab .......................................................................142 14.13.2 Performance Tab ...............................................................143 14.14 Parametric Utility....................................................................145 14.14.1 Neural Networks................................................................146 14.14.2 Variables ..........................................................................148 14.14.3 PM Utility Property View .....................................................149 14.14.4 Neural Network (NN) Manager.............................................164 14.15 Pipe Sizing..............................................................................172 14.15.1 Design Tab .......................................................................172 14.15.2 Performance Tab ...............................................................175 14.16 Property Balance Utility ..........................................................176 14.16.1 Material Balance Tab ..........................................................178 14.16.2 Energy Balance Tab ...........................................................185 14.17 Property Table ........................................................................187 14.17.1 Design Tab .......................................................................188 14.17.2 Performance Tab ...............................................................19214-2 il:cadserv21@hotmail.com only,if tort to your rights,please inform us,we will delete 14-3 Utilities www.cadfamily.com EMa The document is for study 14.17.3 Dynamics Tab ...................................................................195 14.18 Tray Sizing..............................................................................196 14.18.1 Design Tab .......................................................................198 14.18.2 Performance Tab ...............................................................222 14.18.3 Dynamics Tab ...................................................................227 14.18.4 Auto Section .....................................................................227 14.19 User Properties.......................................................................231 14.19.1 Design Tab .......................................................................232 14.19.2 Performance Tab ...............................................................233 14.20 Vessel Sizing...........................................................................235 14.20.1 Design Tab .......................................................................235 14.20.2 Performance Tab ...............................................................240 14.21 References..............................................................................24114-3 il:cadserv21@hotmail.com only,if tort to your rights,please inform us,we will delete 14-4 Introduction ww Th14.1 Introduction The utility commands are a set of tools, which interact with a process by providing additional information or analysis of streams or operations. In HYSYS, utilities become a permanent part of the Flowsheet and are calculated automatically when appropriate. They can also be used as target objects for Adjust operations. Most utilities can also be added through the Utilities page on the Attachments tab of a stream's property view. A utility added through either route is automatically updated in the other location. For example, if you attach an Envelope utility to a stream using the Available Utilities property view, the Envelope utility automatically appears on the Utilities page of the Attachments tab in the property view of the stream to which it was attached. You can select any of the following utilities from the Available Utilities property view: Utilities Description Boiling Point Curves Obtains laboratory-style distillation results for streams. CO2 Freeze Out Determines stream CO2 freezing conditions. Cold Properties Calculates several stream Cold Properties, for example True and Reid Vapour Pressures, Flash Point, Pour Point, Refractive Index, and so forth. Composite Curves Optimizes the use of process heat exchange and utilities for heat exchangers, LNG's, coolers, and heaters. Critical Properties Calculates true and pseudo critical properties for streams. Data Recon Used by HYSYS.RTO optimization objects as a data holder that allows for multiple sets of stream data, each corresponding to a different set. Depressuring- Dynamics Models the pressure letdown of a single vessel or network of vessels under plant emergency conditions. Derivative Used by HYSYS.RTO to hold all the data used for defining the RTO optimizer constraints and variables. Envelope Shows critical values and phase diagrams for a stream. For information on adding the utilities using the Available Utilities property view, refer to the section on Adding a Utility. For further details, refer to Chapter 1 in the Aspen RTO Reference Guide. For further details, refer to Chapter 1 in the Aspen RTO Reference Guide.14-4 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-5 ww ThAdding a Utility 1. Select Tools | Utilities command from the menu bar. The Available Utilities property view appears. You can also access the Available Utilities property view by pressing CTRL U. 2. From the list of available utilities, in the right pane, select the utility you want to add. 3. Click the Add Utility button. The selected utility’s property view appears. Editing a Utility 1. Select Tools | Utilities command from the menu bar. The Available Utilities property view appears. 2. From the list of installed utilities, in the left pane, select the utility you want to view. 3. Click the View Utility button. The selected utility’s property view appears. From here, you can modify any of the utility’s properties. Hydrate Formation Determines stream hydrate formation conditions. Parametric The Parametric Utility integrates Neural Network (NN) technology into its framework. The major function of the utility is to approximate an existing HYSYS model with a parametric model. Pipe Sizing Performs design calculations on any of the case streams. Property Balance Performs balance calculations across any utilities. You can select individual utilities or the entire flowsheet. Property Table Examines stream property trends over a range of conditions. Tray Sizing Size or rate existing sections or full towers. User Property Defines new stream properties based on composition. Vessel Sizing Size and cost installed Separator Unit Operations. Utilities Description14-5 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-6 Introduction ww ThDeleting a Utility 1. Select Tools | Utilities command from the menu bar. The Available Utilities property view appears. 2. From the list of installed utilities, in the left pane, select the utility you want to delete. 3. Click the Delete Utility button. HYSYS will ask you to confirm the deletion. Ignoring a Utility To ignore a utility during simulation calculations: 1. Select Tools | Utilities command from the menu bar. The Available Utilities property view appears. 2. From the list of installed utilities, in the left pane, select the utility you want to view. 3. Click the View Utility button. The selected utility’s property view appears. 4. Select the Ignored checkbox, which is usually located on right bottom corner of the utility’s property view. HYSYS disregards the utility entirely until you restore the utility to an active state by clearing the Ignored checkbox. You can also delete a utility by clicking the Delete button on the utility’s property view.14-6 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-7 ww Th14.2 Boiling Point Curves The Boiling Point Curves utility, which generally is used in conjunction with characterized oils from the Oil Manager, allows you to obtain the results of a laboratory style analysis for your simulation streams. Simulated distillation data including TBP, ASTM D86, D86 (Corr.), D1160(Vac), D1160(Atm), and D2887 as well as critical property data for each cut point and cold property data are calculated. The data can be viewed in a tabular format or graphically. The object for the analysis can be a stream, a phase on any stage of a tray section, or one of the phases in a separator, in a condenser or in a reboiler. You select the basis for the calculations, and you can specify the boiling ranges for the simulated distillation data. Figure 14.1 Refer to Chapter 4 - HYSYS Oil Manager in the HYSYS Simulation Basis guide for details on the distillation data types. To add the Boiling Point Curves utility, refer to the section on Adding a Utility.14-7 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-8 Boiling Point Curves ww Th14.2.1 Design Tab The Design tab contains the following pages: • Connections • Notes Connections Page On the Connections page, you can select the parameters for the Boiling Point Curves utility. Setting the Utility Parameters 1. On the Connections page of the Design tab, change the Name of the utility, if desired. 2. From the Object Type drop-down list, select the object type you want. The options are Stream, Tray Section, Separator, Condenser, or Reboiler. For a tray section, the boiling point curves and critical property data can be accented on the Profiles tab of the Column Runner. Figure 14.214-8 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-9 ww Th3. Click the Select Object button, the Select (object type) view appears. The title of the Select (object type) view depends on the object type you selected. For example, if you select the condenser, the Select Condenser property view appears. 4. Choose the appropriate object from the Object list, and click the OK button to add the selected object to the utility. The Object list can be filtered by selecting one of the radio buttons in the Object Filter group. 5. From the Basis drop-down list, select the basis for the calculation of the distillation data. The options are Mole Frac, Mass Frac, Liquid Volume. 6. For all object types except the Stream selection, from the Phase drop-down list you can select the phase for the analysis as either Vapour or Liquid. 7. If the Object Type which you have selected is a Tray Section, from the Stage drop-down list select a stage. Notes Page The Notes page provides a text editor, where you can record any comments or information regarding the utility, or to your simulation case in general. Figure 14.3 For more information, refer to Section 1.3.5 - Notes Page/Tab.14-9 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-10 Boiling Point Curves ww Th14.2.2 Performance Tab The Performance tab contains the following pages: • Results • Critical Props • Cold Props • Plots Results Page You can view the results of the boiling point curve calculations in tabular format on the Results page. Simulated distillation profiles are provided for the following assay types: • TBP • ASTM D86 • D86 Corr. • ASTM D1160 (Vac.) • ASTM D1160 (Atm.) • ASTM D2887 Figure 14.414-10 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-11 ww ThThe ASTM D86 boiling point curve corresponds to the true boiling points of the oil, which assumes no cracking has occurred. When the oil is characterized by a ASTM D86 distillation assay with no cracking option, the D86 Corr boiling point curve corresponds to the assay input data. The ASTM D86 boiling point curve then corresponds to raw lab data, with no cracking correction applied. When the oil is characterized by a ASTM D86 distillation assay with cracking option, the ASTM D86 boiling point curve corresponds to the assay input data. The cracking correction factor is then applied to the D86 Corr boiling point curve. [American Society for Testing Materials, part 23, Philadelphia, PA (1982)] Critical Props Page The Critical Props page contains, for each cut point, the critical temperature, critical pressure, acentric factor, molecular weight, and liquid density. Figure 14.514-11 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-12 Boiling Point Curves ww ThCold Props Page You can view the bulk cold properties of the stream on the Cold Props page. Also listed is the ratio of paraffins to naphthas to aromatics. Plots Page The Plots page shows the Boiling Point Curves results and the Critical Properties results in graphical form. Examine the plot of your choice by making a selection from the Dependent Variable drop-down list: • Boiling Point Curves • Critical Temperature • Critical Pressure • Acentric Factor • Molecular Weight • Liquid Density You can customize a plot by right-clicking in the plot area, and selecting Graph Control command from the object inspect menu. Figure 14.6 Details of the methods used to determine the Cold Properties can be found in Section 14.4 - Cold Properties. Refer to Section 1.3.1 - Graph Control Property View for more information.14-12 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-13 ww ThThe figure below shows an example of the Plots page. 14.2.3 Dynamics Tab The Dynamics tab allows you to control how often the utility gets calculated when running in Dynamic mode. The Control Period field is used to specify the frequency that the utility is calculated. A value of 10 indicates that the utility be recalculated every 10th pressure flow step. This can help speed up your dynamic simulation since utilities can require some time to calculate. The Use Default Periods checkbox allows you to set the control period of one utility to equal the control period of any other utilities that you have in the simulation. For example, if you have five utilities, and require them all to have a control period of 5 and currently the value is 8, with this checkbox selected if you change the value in one utility all the other utilities change. Alternatively, if you want all the utilities to have different values you would clear this checkbox. The Enable in Dynamics checkbox is used to activate this feature for use in Dynamic mode. The Calculate Now button allows you to calculate in dynamics mode when the integrator is not running. Figure 14.714-13 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-14 CO2 Solids ww Th14.3 CO2 Solids An equation-of-state based approach is used to calculate the incipient solid formation point for mixtures containing Carbon Dioxide (CO2). The model can be used for predicting the initial solid formation point in equilibrium with either vapours or liquids. The fugacity of the resultant solid is obtained from the known vapour pressure of solid CO2. The fugacity of the corresponding phase (in equilibrium with the solid) is calculated from the equation of state. Figure 14.8 CO2 Solids prediction is restricted to the Peng Robinson (PR) and Soave Redlich Kwong (SRK) equations of state. To add the CO2 Freeze Out utility, refer to the section on Adding a Utility.14-14 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-15 ww Th14.3.1 Design Tab The Design tab contains the following pages: • Connections • Notes Connections Page You are required to specify the stream for which the calculations are made on the Connections page. You can select the stream from the Select Process Stream property view, which is accessed by clicking the Select Stream button. HYSYS determines the CO2 Freeze Temperature, and displays the formation status in the Formation Flag field: Figure 14.9 Formation Flag Flag Significance Undetermined No Stream has been chosen. NO CO2 in Stream There is no CO2 present in the Stream.14-15 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-16 CO2 Solids ww ThIn the Tolerance field, you can specify the tolerance used to calculate the incipient solid formation point. Notes Page The Notes page provides a text editor, where you can record any comments or information regarding the utility, or to your simulation case in general. 14.3.2 Dynamics Tab The Dynamics tab allows you to control how often the utility gets calculated when running in Dynamic mode. The Control Period field is used to specify the frequency that the utility is calculated. A value of 10 indicates that the utility be recalculated every 10th pressure flow step. This can help speed up your dynamic simulation since utilities can require some time to calculate. Does NOT Form Solid CO2 not form at the present conditions of the stream. The CO2 Freeze Temperature is shown in the corresponding field. Solid CO2 Present Solid CO2 is present at the current stream conditions. The CO2 Freeze Temperature is shown in the corresponding field. Figure 14.10 Formation Flag Flag Significance For more information, refer to Section 1.3.5 - Notes Page/Tab.14-16 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-17 ww ThThe Use Default Periods checkbox allows you to set the control period of one utility to equal the control period of any other utilities that you have in the simulation. For example, if you have five utilities, and require them all to have a control period of 5 and currently the value is 8, with this checkbox selected if you change the value in one utility all the other utilities change. Alternatively, if you want all the utilities to have different values you would clear this checkbox. The Enable in Dynamics checkbox enables the Use Default Periods feature for use in Dynamic mode. 14.4 Cold Properties The Cold Properties utility enables you to view the cold properties of a stream. The following list summarizes the cold properties which are available through the Cold Properties utility: Figure 14.11 To add the Cold Properties utility, refer to the section on Adding a Utility. Cold Property Calculations Range of Validity True Vapour Pressure @ 100°F (37.8°C) Vapour Pressure method of selected property package P>1.5 kPa Reid Vapour Pressure @ 100°F (37.8°C) Vapour pressure of system when vapour:liquid ratio by volume is 4:1 P>1.5 kPa14-17 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-18 Cold Properties ww Th14.4.1 Design Tab The Design tab contains the following pages: • Connections • Notes Flash Point As per API 2B7.1 150°F 70 Cold Property Calculations Range of Validity14-18 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-19 ww ThConnections Page You can attach a stream to the utility, view the streams properties, and select the calculation methods for certain property values on the Connections page. The View Picker offers two views: Values and Options. Values displays the following property values in the Properties group: • True Vapour Pressure • Reid Vapour Pressure • Flash Point • Pour Point • Refractive Index • Cetane Index • Research Octane Number • Viscosity at 100°F (37.8°C) and 210°F (98.6°C) Options allows you to view and choose the calculation methods Figure 14.1214-19 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-20 Cold Properties ww Thfor the property values. Notes Page The Notes page provides a text editor, where you can record any comments or information regarding the utility, or to your simulation case in general. Calculation Options Reid VP at 37.8 C • HYSYS RVP (default) • Aspen RVP-API Flash Point • HYSYS Flash Point API (default) • Aspen Pennsky-Martens • Aspen Tag Cetane Index • HYSYS Default (default) • Aspen Collins-Unzelman For more information, refer to Section 1.3.5 - Notes Page/Tab.14-20 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-21 ww Th14.4.2 Performance Tab The Performance tab contains a BP and a PNA page. BP Page The BP page displays the simulated distillation profiles for ASTM D86 and D86 Crack Reduced assay types at 10%, 30%, 50%, 70%, and 90%. You can change the calculation method for the D86 Distillation Curves by clicking the drop down arrow next to the ASTMD86 field in the Calculation Methods group. PNA Page The PNA page displays the ratio of paraffins to naphthenes to aromatics. The default calculation method for the D86 Distillation Curves is the method chosen in the Tools | Preferences window. If the method is changed to API 1987, any new Cold Properties Utility will have the HYSYS API 1987 method chosen for the D86 curves. Existing Cold Property Utilities will not be affected.14-21 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-22 Cold Properties ww Th14.4.3 Dynamics Tab The Dynamics tab allows you to control how often the utility gets calculated when running in Dynamic mode. The Control Period field is used to specify the frequency that the utility is calculated. A value of 10 indicates that the utility be recalculated every 10th pressure flow step. This can help speed up your dynamic simulation since utilities can require some time to calculate. The Use Default Periods checkbox allows you to set the control period of one utility to equal the control period of any other utilities that you have in the simulation. For example, if you have five utilities, and require them all to have a control period of 5 and currently the value is 8, with this checkbox selected if you change the value in one utility all the other utilities change. Alternatively, if you want all the utilities to have different values you would clear this checkbox. The Enable in Dynamics checkbox is used to activate this feature for use in Dynamic mode. Figure 14.1314-22 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-23 ww Th14.5 Composite Curves Utility Pinch technology is a methodology, which is used to optimize the use of process heat exchange and utilities in complicated processes. The HYSYS Composite Curves utility provides the necessary tools to apply the pinch principles in the design of efficient heat exchanger networks. For further pinch analysis information, refer to the text by Marsland1. You can attach any combination of heat exchangers, LNG operations, heaters or coolers to the Composite Curves utility. The only requirement being that each operation is solved so the Pinch calculations can be performed. 14.5.1 Design Tab The Design tab contains the following pages: • Connections • Notes Figure 14.14 To add the Composite Curves utility, refer to the section on Adding a Utility.14-23 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-24 Composite Curves Utility ww ThConnections Page On the Connections page, you can attach any combination of heat exchangers, LNG operations, heaters, and coolers to the utility. Adding a Heat Exchanger Object 1. On the Connections page of the Design tab, click the Select Heat Exchanger Object button. 2. The Select Heat Exchanger Object property view appears. 3. From the property view, select the heat exchanger, LNG, heater or cooler you want from the Object list. The Object list can be filtered by selecting one of the radio buttons in the Object Filter group. 4. Click the OK button to add the selected object to the utility. Figure 14.1514-24 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-25 ww ThRemoving a Heat Exchanger Object 1. On the Connections page of the Design tab, select the heat exchanger object you want to remove from the list. 2. Press the DELETE button. Notes Page The Notes page provides a text editor, where you can record any comments or information regarding the utility, or to your simulation case in general. 14.5.2 Performance Tab The Performance tab contains the following pages: • Side Results • Pinch Results • Table • Plots Figure 14.16 For more information, refer to Section 1.3.5 - Notes Page/Tab.14-25 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-26 Composite Curves Utility ww ThSide Results Page On the Side Results page, you can view the inlet temperature, outlet temperature, and molar flow of each pass attached to the Composite Curves utility. Pinch Results Page The various results of the Composite Curves utility can be examined on the Pinch Results page. The results which can be examined include the following: • Hot Pinch Temperature • Cold Pinch Temperature • Minimum Approach. Temperature difference between the Hot Pinch and Cold Pinch. • Average Temperature at Pinch • Enthalpy Change at Pinch Figure 14.17 Figure 14.1814-26 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-27 ww Th• Cold Utility • Hot Utility • Number of Points. The number of intervals used in the Composite Curves utility calculations. • Minimum Approach Target. Specifiable minimum approach temperature. • Cold Utility Target. Specifiable cold utility enthalpy value. • Hot Utility Target. Specifiable hot utility enthalpy value. Table Page The Table page shows a tabular report of what is seen on the Plots page. You can view temperatures of the Sink and Source, the LMTD and enthalpy change for each interval. Figure 14.1914-27 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-28 Composite Curves Utility ww ThPlots Page On the Plots page, you can view the Sink and Source Composite Curves or the Grand Composite Curve. Make your selection from the Graph Type drop-down list. The Composite Curves for the heat exchanger network is shown in the figure below. Notice the pinch also appears on this plot. You can edit the plot by right-clicking anywhere in the plot area, and selecting the Graph Control command from the object inspect menu. Figure 14.20 Refer to Section 1.3.1 - Graph Control Property View for more information about manipulating plots.14-28 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-29 ww Th14.6 Critical Properties The Critical Properties utility calculates both the true and pseudo critical temperature, pressure, volume, and compressibility factor for a fully defined stream. True & Pseudo Critical Properties The Critical Properties utility displays two sets of critical properties, true and pseudo critical properties. True Critical Properties are those properties calculated using the mixing rules associated with the property package chosen. Pseudo Critical Properties use simple linear models to estimate the critical properties of a mixture. They are often very different from the true critical points and have no real physical significance, but sometimes are used in empirical correlations. Mathematically, the pseudo critical temperature, pressure, and compressibility (Tpc, Ppc, and Zpc) are defined as: (14.1) (14.2) (14.3) To add the Critical Properties utility, refer to the section on Adding a Utility. Tpc yiTci i 1= n ∑= Ppc yiPci i 1= n ∑= Zpc yiZci i 1= n ∑=14-29 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-30 Critical Properties ww Thwhere: yi = mole fraction of component i n = total number of components in mixture Tci = critical temperature of component i Pci = critical pressure of component i Zci = critical compressibility of component i The remaining pseudo critical property, pseudo critical volume vpc, is calculated using the following relationship: (14.4) Figure 14.21 You must set up a fluid package using the Peng Robinson property method to use this utility. vpc ZpcTpcR Ppc --------------------=14-30 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-31 ww Th14.6.1 Design Tab The Design tab contains the following pages: • Connections • Notes Connections Page You can connect the utility to a stream, and change the name of the utility on this page. The following is the general procedure for connecting a stream to the Critical Properties utility: 1. On the Critical Properties property view, specify the name of the utility. 2. Click the Select Stream button. The Select Process Stream property view appears. 3. Select the stream you created from the Object list. The Object list can be filtered by selecting one of the radio buttons in the Object Filter group. 4. Click the OK button to add the selected stream to the utility. Figure 14.2214-31 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-32 Critical Properties ww ThCritical Property Analysis You can examine the critical property values for the selected stream in the Properties group. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the utility or your simulation case in general. 14.6.2 Dynamics Tab The Dynamics tab allows you to control how often the utility gets calculated when running in Dynamic mode. The Control Period field is used to specify the frequency that the utility is calculated. A value of 10 indicates that the utility be recalculated every 10th pressure flow step. This can help speed up your dynamic simulation since utilities can require some time to calculate. Figure 14.23 For more information, refer to Section 1.3.5 - Notes Page/Tab.14-32 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-33 ww ThThe Use Default Periods checkbox allows you to set the control period of one utility to equal the control period of any other utilities that you have in the simulation. For example, if you have five utilities, and require them all to have a control period of 5 and currently the value is 8, with this checkbox selected if you change the value in one utility all the other utilities change. Alternatively, if you want all the utilities to have different values you would clear this checkbox. The Enable in Dynamics checkbox is used to activate this feature for use in Dynamic mode. 14.7 Data Reconciliation Utility Modern instrumentation and distributed control and management information systems produce a wealth of plant data. The plant operator/manager has a problem making sense of all this data where: • It may be inconsistent or inaccurate. • It may not give a complete or understandable indication of plant performance. In addition, plant models can only be configured to a specific operational instance, whereas the performance of actual equipment varies as conditions change and equipment degrades. Thus, the model behaviour may start to diverge from actual plant behaviour. The Data Reconciliation Utility (DRU) addresses these issues and produces concise information to aid decision making and aid model tuning and off-line investigation. To add the Data Recon utility, refer to the section on Adding a Utility.14-33 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-34 Data Reconciliation Utility ww ThFirstly, it can perform data reconciliation. Measurements are subject to error and, therefore, provide inconsistent information. DRU can detect and correct measurement errors, thereby providing a consistent and accurate data set. Secondly, a model representing a specific item of plant can be updated whereby DRU is able to reconcile model and actual plant values, to ensure that the model continues to represent actual plant performance. The DRU brings real benefits by ensuring good representation of plant equipment, and providing indications of poor plant data as an aid to decision making in the following areas: • Identification of process unit performance, in particular condition monitoring. • Identification and quantification of instrument errors. This leads to improvements due to: • Better process operation in general. • More effective and efficient equipment maintenance and/ or replacement. • More effective and efficient instrument maintenance. • Improved plant model representation. Current applications of the DRU include: • Compressor model updating/condition monitoring • Catalyst performance monitoring/updating • Thermal cracker model updating • Steam system data reconciliation • Gas turbine model parameter updating • Heat exchanger fouling effect updating • Reactor model parameter updating • Boiler model updating and condition monitoring • General network reconciliation (e.g., oil & gas fields, steam systems, etc.) In fact, anywhere where plant measurements are available around process equipment, the DRU can be applied.14-34 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-35 ww ThThe DRU offers the following facilities: • Error Detection/Correction - No measurement is perfect, so by using a number of sets of data and statistical routines, the DRU sorts the good from the bad and only uses good data. This is a pre-requisite for model updating and the essence of data reconciliation. • Model Updating - The DRU can update the parameters of even the most complex model. • Utilities - The DRU invokes a number of statistical and optimization routines to perform the following tasks: - Parameter Estimation - Calculation of model parameters which may change with time, such as reaction rate coefficients, heat transfer coefficients, etc. - Data Reconciliation - Model based reconciliation of over-determined systems, such as steam system mass balancing, where there are many flow-meters, or estimation of power output of a turbine with both steam flow and driven load being measured. - Bad Data Elimination - Results of data reconciliation calculations can be examined statistically to determine whether bad data is present, and if so eliminate the bad data. 14.7.1 Data Reconciliation Utility Property View Four buttons are at the bottom of the DRU property view: • Delete - deletes the DRU • Data Set Analysis - brings up a property view that shows how well each variable behaves over up to 15 data sets, or how up to 15 variables perform against observed plant data for any particular data set. To show the stastical accuracy of the model, this view displays: - the absolute and percentage difference between the observed and predicted data - the arithmetic average and standard deviation of these differences • The property view includes both ‘Good’ and ‘Bad’ data. To run the analysis, select the data sets to be included in the analysis and either input tags or output tags. Click Run. • Fresh Attachments - Refreshes the attachments to the utility • Close - Closes the DRU14-35 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-36 Data Reconciliation Utility ww ThConfiguration Tab The Configuration tab of the Data Reconciliation Utility property view is comprised of the following three groups: • Problem Formulation • Solver Parameters and Tolerances • Data Set Configuration The DRU configuration tab is identical to the Optimizer DataRecon Configuration tab and is detailed below. In addition, the utility produces a diagnostic file: Diagnostic Print Level can be set to levels of None, through to Downpour (no diagnostic through to full diagnostics) using the drop-down list. Problem Formulation Group This group defines the main user-controls to be supplied with data to fit the parameter and/or measured data offsets. In the Fitting column, the parameter fitting can be switched off or on using the Mode cell. Problem Formulation Description Perform Calculations These checkboxes indicate which calculations are being performed. Mode The options for Fitting are Offset Only or Fit Params. The options for Gross Error Detection are Full or Shortcut. Run After A N counter that allows the DRU model to be exercised to only perform the fit calculations every N-th time. This allows the associated measurement data blocks to gather the historical data without full recalculation being performed for each new data set. If required, the counter can be set to 1. If the DRU model has a Run After N value set, it only runs every N-th time, allowing the data blocks to build up the historical data for the actual fitting calculations. This allows the historical data to be stored before the fitting calculations are performed. Current This indicates the current number of runs related to the Run After.14-36 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-37 ww ThGross Error Detection and Bad Data Elimination Bad data elimination is specified by selecting the Gross Error Detection:Perform Calculations flag. This selection assumes that the DRU is configured with the offset data blocks that correspond to the measurements that are available for elimination. The Mode indicates whether Full fitting is performed, or if a Shortcut (single) data set is used. The single data set mode uses the first good set, and does not fit parameters defined in the DRU Parameter Fit tab. The purpose of this mode is to provide a quick method of determining bad data within a single set based on the associated model. After the DRU is run with these settings, the results are displayed on the Results tab. No. of Eliminations shows how many data blocks are eliminated in the given problem, and Max Eliminations shows how many accepted eliminations are allowed before the fitting cannot be exercised further. The confidence is similar to that for the standard fitting, in that it is used to calculate the Maximum x2 to determine whether a good fit was achieved. The Fit Error (Total) is compared to the maximum tolerance to give the Goodness of Fit flag. The tolerance figure is based on a x2 distribution for the offsets only, expecting a good fit to have small offsets close to zero value. The fitting calculation is always performed when the elimination model is run. Confidence The Confidence can be set to determine the level of fit required for a good result. The higher the confidence, the closer the fit needs to be to a normalized curve for the fit to be deemed good. Maximum Allows you to enter a maximum number of iterations (error function gradient evaluations, i.e., optimizer moves) for calculating the optimal parameters. Problem Formulation Description14-37 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-38 Data Reconciliation Utility ww ThData Set Configuration Group The Data Set Configuration allows you to configure the minimum, maximum, and current Data Sets. Solver Parameters & Tolerances Group The DRU tolerances can be user defined using the Data Reconciliation Utility property view. If tolerances are not defined, default values (generated/set by the optimization algorithm) are used. You can select between the MDC and MSL solver methods. The MDC solver parameters and tolerances that are available are described below. Data Set Description Minimum Data Sets The minimum number of good data sets required for an DRU calculation. A good data set is one that is not excluded at the start of the DRU calculation. Maximum Data Sets The maximum number of historical data sets to be stored locally during the estimation, but not necessarily all used. You can set this to store as many time-slices of information, although the upper limit is 32. Current Data Sets The number of data sets in the parameter estimation problem.Eventually, after a sufficient number of DRU runs this number is equal to the Maximum Data Sets parameter. Horizon The measurement horizon for the data. This gives the number of most-recent data sets to be used in the DRU, out of the Maximum Data Sets stored. In order to use the MDC Estim solver, you must have a HYSYS.RTO license.14-38 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-39 ww ThParameters & Tolerances Description Central & Forward Differences Intervals that are used to determine the perturbation in the parameters / offset used for the calculation of the (error function) objective gradients with respect to the variables. If these values are not set, the optimization routine uses additional model evaluations to determine the values to be used. Optimality Tolerance The smallest relative change in the total error function during the error minimization below which the optimization is deemed to have converged by the algorithm. Linesearch Tolerance that is used by the optimization routine to determine the accuracy of the optimal step with respect to the gradient evaluations. The larger the Linesearch tolerance, the further along the optimal path the next optimal step will be. This number must be between zero and one. Maximum Step Determines how far each of the variables (parameters, offsets) can be moved in an optimal step. This prevents the optimizer from overstepping on each iteration, thus speeding up the solution. Objective Scaling Allows the emphasis between offset and parameter fitting to be varied when both offsets and parameters are fitted simultaneously. The emphasis is squared based on the given number; a function scale factor of 10 places 100 times more emphasis on the elimination of measured / model error than on fitting the offsets. Convergence Tolerance The smallest change to occur to every parameter/ offset below which the minimization is deemed to have converged. Default Responses If the checkbox is selected, the DRU automatically answers “Yes” if there are datasheets that need to be removed. It also answers “No” to the query about whether the DRU should start solving from the last parameter result value. It uses the Start value instead.14-39 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-40 Data Reconciliation Utility ww ThIf the MSL solver method is selected, the Gross Error Detection and Data Elimination options are not available for the Problem Formulation group. The following figure shows the parameters and tolerances that the MSL method uses for the DRU. The MSL solver parameters and tolerances are described below. Figure 14.24 MSL Parameters & Tol Description Forward Difference (FD) Interval used to calculate the perturbations for calculating the Jacobian matrix. FD high or FD low is used. If neither high or low methods are used, by default, they are set to 0.9*current value and 1.1*current value, respectively. Jacobian steps are always forward, for example, if the last step caused an increase in a variable then the jacobian calculation steps will also be in the same direction. Reset Perts It is recommended to have this option selected. All Jacobian perturbations are calculated from the same point ensuring a more accurate Jacobian. Although, this increases the solve time.14-40 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-41 ww ThThe Maximum Iteration Limit determines the maximum number of iterations allowed to the optimizer to generate its optimal solution. Generally, after approximately five iterations, the optimizer is close enough to the fitting solution to be terminated with confidence. This is because the optimization problem is unconstrained, the only limits are imposed from the parameters. LMDer Data Check The Data Check is only used when the LMDer Solver Method is selected. It assesses the data sets to see if any of them are out of sync (possibly a bad data set). DRU prompts the user if these sets need to be removed. The results of the sets that are removed are displayed on the Info page of the DCS tags tab. Solver Method The MSL solver allows you to select from the LMDer (used in Sim Adjusts) and the NS23 (HSL method) methods. • LMDer - The Levenberg-Marquardt algorithm that solves equations by minimizing the sum of squares of the residuals on the right hand side. Levenberg-Marquardt is thus a specialized optimization function for least squares. • NS13 - This solver is intended for large, sparse systems. It is recommended to use the LMDer, although the NS23 may prove to be better in some situations. MSL Parameters & Tol Description14-41 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-42 Data Reconciliation Utility ww ThResults Tab The updating routine produces a set of results that can be seen on the Results tab . The Results tab is displayed based on the MDC solver method. Figure 14.25 If the MSL solver is selected, only relevant parameters are displayed.14-42 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-43 ww ThThe Parameter Fitting results are described below. A summary of the user-supplied parameters is also supplied in the Number Of group. Parameter/Offsets These are the most important results obtained from the updating. They define the parameters which most accurately describe the actual plant for the data given in the model input and output blocks. The parameter results can be viewed on the Parameter Fit tab. Parameter Fitting Description Chi2 Maximum Chi2 The value of x2 gives the x2 calculation based on the sum of the data block errors scaled by the sigma, s, for each of the output data blocks. This value is then checked against the maximum x2 value (Maximum Chi2), which is calculated from the stated confidence and the calculated number of degrees of freedom (Degrees of Freedom) for the problem. If the calculated x2 value is less than the maximum value, the Fit flag is deemed good, and the parameters and offsets are updated. A bad fit leaves the parameters and offsets with their original values. Goodness of Fit The Goodness of Fit returns whether a good or bad fit was returned by the x2-test. Major Iterations indicates the number of parameter variation steps undertaken by the optimization algorithm with minimizing the total error. Fit Error (Total) The Fit Error (Total) gives the total sum of errors for all datablocks of each good historical data-set. The sum is between the measured values and the model calculated values, the error being calculated using the final value of the predicted parameters and measurement offsets. Starting Objective Final Objective The change in objective function can be seen by comparing the Starting Objective to Final Objective. The objective quoted is the actual objective seen by the optimization routine, and is based on the scaled offsets and error functions. Function Calls The value for Function Calls indicates how many times the plant model was executed by the updating algorithm in arriving at the fit answer. Major Iterations The value indicates how many times the objective function has been evaluated by the optimizer.14-43 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-44 Data Reconciliation Utility ww ThThe calculated offsets can be seen by examining the individual data blocks on the DCS Tags tab as shown in the next section. In most cases, successive updating over time should result in a progressively more accurate solution. Stream Initialization Tab Figure 14.26 shows the Stream Initialization tab. This indicates the connections from the estimated entries in the plant model to the measurement data list that contains the input and the output measurement data blocks. The screen identifies whether a measurement data block is a model input or calculated result. This form displays information concerning flowsheet model inlet / outlet streams, energy streams, and internal streams. An inlet stream is a stream in the model that is an inlet to a reconciled unit operation (targeted using the Target Objects button), but not an outlet. An outlet stream is an outlet to a reconciled unit operation, but not an inlet. Figure 14.2614-44 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-45 ww ThEnergy stream refers to the standard HYSYS energy streams. Internal streams are both inlet and outlet streams (i.e., are both feeds and products to unit operations), or are either feeds or products to a unit operation which is not reconciled. The initialization prior to carrying out a run of the estimation is done using DRU streams, streams created by you specially for the purpose of storing simulated plant data in flowsheet streams; the DRU streams are effectively storage mechanisms. The Multiple flag column indicates whether historical data is available for the flowsheet stream, data which is stored in the DRU object; if unchecked, any specified values of the corresponding flowsheet stream are held constant for the duration of the parameter estimation. The Data Sets column indicates the number of data sets available for each stream kind. The Comp Basis column represents the basis for the component calculation in each stream. Parameter Fit Tab The model parameters can be accessed from the Parameter Fit tab of the Data Reconciliation Utility property view. Figure 14.2714-45 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-46 Data Reconciliation Utility ww ThThese parameters are adjusted to give the best fit for the model to the data given in the output blocks. For example, the efficiency of a heat exchanger or the reaction coefficients of a reactor model. The Start and Current values show the values of the parameters before and after an update was carried out. After an update, and only if the fit is good, the new values are placed directly into the model. The Result Value stores the value of the parameter after the last run of the DRU. The Hooked Object/Variable refer to the object and property in the flowsheet model which is estimated. The Fit allows you to turn on/off the fitting parameters. The Minimum and Maximum values define the range over which the parameters are allowed to vary. These values should be considered carefully so as not to constrain the model to a region in which the model solution is greatly different from the actual plant. The range is also used in calculating the Jacobian set-size. DCS Tags Tab The DCS Tags tab is used for defining the transfer of measured data to the flowsheet model during the DRU calculations. Figure 14.2814-46 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-47 ww ThThe Tag Filter group has options to display model Input data, Output data, or All data (input and output), depending on the radio button selected. Input data consists of property values of streams that are read in the model, but are not reconciled. Output data, consisting of property values, are then reconciled to these (read) values by the parameter estimation algorithms in the DRU. If MSL is the solving method selected, the Low Limit parameter is added and all other non-applicable parameters are removed. The following table shows a quick outline on the parameters you may encounter when setting up the DCS Tag Set-up. These parameters are detailed in earlier sections. Parameters Description Property Allows you to enter a name for the tag. Click the tag name to view the DCS tag properties/connections. Current Value Value of the parameter in the flowsheet. Scale This scales errors for the Objective Function. Offset Bias/offset calculated by DRU or can be specified by the user. Limit The upper limit on the tag. Low Limit The lower limit on the tag. Total Error The error between the measured data and HYSYS data. Calculate Bias Calculates a bias for the tag. Use Bias Allows you to use a specified/calculated bias in the calculation. Input A tag that is used as an input variable.14-47 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-48 Data Reconciliation Utility ww Th14.7.2 Optimization Objects An DRU stream and DCS Tags are considered to be Optimization Objects. These optimization objects are input tags or output tags, corresponding to input or output data from the model. These objects can be accessed by selecting Optimization Objects from the Flowsheet menu on the desktop. A given optimization object can be edited by highlighting it and clicking the Edit button on the Select Optimization Object property view. The Optimization Object property view for the selected object displays. There are three tabs in this property view: • Connection • Properties • Transfer These tabs are described in the following sections. Figure 14.2914-48 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-49 ww ThConnection Tab The Connection tab gives the connections of an optimization object to the flowsheet Object name. The connection in this case is DCS tag to the Mass Flow of the Feed. Properties Tab The second tab lists the Properties of an optimization object. Figure 14.30 Figure 14.3114-49 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-50 Data Reconciliation Utility ww ThThe myvarval property (“my variable value”) stores the value of the connected object property. The scale value is used to scale the measured values, and hence the (measured - model) error, to ensure the optimizer objective function sees the errors with required weightings. Generally, the scaling should be selected so that the relative values for each of the errors on the model outputs is approximately equal. This ensures the optimizer selects a fair set of parameters and/or offsets to fit equally on the measured outputs. If an output is to be favoured, its scaling should be smaller so the relative error is larger, forcing the optimizer to correct that error over the other errors. For offset fitting, the scaling is important for both input and output blocks since the offset is scaled by this amount for the objective function. For output blocks the scaling is also used to calculate the relative error between the measured and model values, so offset is scaled the same as the error. To counter this, the DRU tolerances allow the overall offset portion of the objective function to be scaled differently to the error portion, thus enabling preference of fitting for either offsets or parameters. When parameter fitting only, the scaling is only relevant to the output blocks where it is used to scale the absolute error to a relative error. The offset value indicates the absolute offset to be applied to the measure values; this can be a fixed, known amount, or an offset calculated by the fitting algorithm. The exact use is determined by the set-up flags in the data block. For offset fitting, there are no minimum and maximum limits since the optimizer is attempting to minimize the value of the offsets, and thus be driving them to zero.14-50 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-51 ww ThThe error property stores the calculated error between the fitted model data and the actual measured data, for a given data set. The sigma property is an estimate of the true asymptotic standard deviations of the measured value from the plant. The estimate is updated at each run of the DRU in such a way it causes it to asymptotically approach the correct value for the instrument. The update takes account of the current value of sigma, and weighting which takes into account the previous estimate. The initial value of sigma selected is typically large (~1000), to provide a good initial fit. Sigma is only calculated for output data blocks (Output Tags). The value of sigma is used to calculate the goodness of fit; the scaled error between model calculated value and the measured value is divided by the sigma value to determine the effect of the data block in the overall x2 fit calculations. The smaller the value, the smaller the error allowed to maintain a good fit. Where the sigma is not reset on each run, the closer the measured value is to the model value, the smaller the calculated sigma is for use in the cumulative sigma update. As this is calculated cumulatively, it tends to its natural sigma value. It should be noted that the sigma value is only used for the goodness of fit calculations, and plays no part in the actual fitting optimization. The next_value property is the value most recently assigned to the given tag (i.e., as if it were read in from a DCS system). The remaining properties have no unit dependency on the connection: • Count. Number of measured value updates to the DCS Tag since the last estimation run. • Totcount. Total number of measured value updates. • Calc_bias. Used to tell the algorithm that the data block is to be included in the offset fitting set, and thus the offset is adjusted to attempt to minimize the measured/ model error. If the data-block is set to calculate offsets, then it is also included in the bad data elimination algorithm. • Over_data. Not currently used in the DRU. • Next_good. Stores whether the next value (obtained from the use in the offline case, or from a DCS system in the on-line case) is considered good or bad data.14-51 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-52 Data Reconciliation Utility ww Th• Input. Indicates if the variable is an input to the model or not. • Use_bias. Set by the user if you want to use the current biases during model runs, not the updated ones, if they are calculated. The flag tells the algorithm that a fixed, known offset is to be applied to each set of measured data for use in the generation of measure/model error. In this case, the offset value is not calculated, and the data block is not included for elimination in the bad data elimination algorithm. • Fill. Reserved for future use. • Eliminated. Returned as a result from the bad data elimination algorithm to indicate that the data set is deemed bad. In this case, the offset is removed from the objective function and allowed to “float”. The resultant model calculated value is then available from the myvarval field. The flag can also be used during normal offset fitting to determine a model calculated value without restricting the offset in the normal optimization objective function. • Curval, and curerror. Indicates the current value and error of the object in the calculation. Transfer Tab The Transfer tab lists the Transfer flags of an optimization object. These flag properties are not used in the offline situation. Figure 14.3214-52 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-53 ww Th14.7.3 DRU Diagnostic File Output The following section details the diagnostics available from DRU and the associated optimization routine. There are three sections produced in the diagnostic output from an DRU run. These sections are covered separately. In addition, several levels of output are available, based on the level selected within the DRU. The descriptions below deal with diagnostics produced when the Downpour diagnostic option is selected. All output produced is generated by the optimization routines; MDC Technology Ltd. do not currently supply additional output from the DRU routine. The name of the diagnostic file produced by the DRU is of the form .txt, where is the name of your DRU object in HYSYS. Initial Problem Parameters The first section of output produced by the optimization routine details the input parameters for the particular problem to be solved. These are either supplied as a result of the problem, or are defaults used by the algorithm. Since the application of the optimizer to the DRU task is an unconstrained problem, several of the parameters and variables produced as part of the output are not relevant to the task and should be ignored. • Linear constraints. Number of linear constraints in the problem. This is not applicable for DRU. • Linear feasibility. Maximum acceptable violation of linear constraints at a feasible point. This is not applicable for DRU. • Variables. Number of variables (parameters or offsets) to be optimized (fitted) in the current problem. • Crash tolerance. Used when COLD start is selected. Variables within this tolerance of their bounds are selected for the initial working set of the problem. • Infinite bound size. Any bound greater/less than this number is considered +/- .∞14-53 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-54 Data Reconciliation Utility ww Th• COLD start. Specifies the initial working set for the problem. This is selected from the initial value of the variables, including variables at, near, or just violating their bounds. • Infinite step size. Magnitude of a change in the variables that would indicate an unbounded problem (the objective is said to be unbounded in the feasible region). Since DRU variables are all bounded between -1 and +1, this parameter is not relevant to an DRU task. • EPS (machine precision). The machine precision, used to determine the default values for several other parameters. • Step limit. The maximum change in a variable on the first step of the linesearch. This prevents overflow situations from occurring. • Nonlinear constraints. The number of non-linear constraints. This is not applicable for DRU problems. • Nonlinear feasibility. The maximum acceptable violation of non-linear constraints at a feasible point. This is not applicable for DRU problems. • Nonlinear objective vars. Number of (non-linear) variables used to minimize the objective function. • Optimality tolerance. The accuracy of the final iterate to approximate a solution to the problem, i.e. a solution is deemed valid if the relative change in the objective function is less than this tolerance. In effect, this value indicates the number of correct figures required in the objective function at solution (i.e. if the tolerance is 10-6 and the optimization terminated successfully, approximately the first six figures of the objective function are correct. This is an indication of the “tightness” of the problem solution. • Nonlinear Jacobian vars. The number of variables used to evaluate the Jacobian matrix of the problem. • Linesearch tolerance. The accuracy of the step taken during each iteration to approximate a minimum of the merit function along the search direction. This determines how far along the search path the next point is to be taken. • Derivative level. This indicates how many of the objective (and constraint) gradients are supplied to the algorithm. DRU uses the algorithm with a level of 0, which indicates that all gradients are not supplied, and have to be calculated using difference approximations. • Function precision. The accuracy with which functions are assumed to be evaluated.14-54 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-55 ww Th• Verify level. A value of zero indicates that the optimization routine performs a 'cheap' finite-difference test on the objective gradient components of the problem. This is not applicable for DRU (where no gradients are supplied). • Major iterations limit. The maximum number of major iterations performed before the problem is terminated (unsuccessfully). • Major print level. Determines the output level on each major iteration. • Minor iterations limit. The maximum number of iterations used to calculate the optimality of the QP subproblem. • Minor print level. Determines the output level on each minor iteration. • Difference interval. The interval used in the forward difference approximation for the objective gradients in the Jacobian matrix. • Central difference interval. The interval used in the central difference approximation for the objective gradients in the Jacobian matrix. Central difference approximations are used if the forward difference approximations are found to be not accurate enough. • JTJ initial Hessian. Controls the initial value of the upper triangular matrix R (the estimate of the transformed and re-ordered Hessian of the Lagrangian). J is the objective Jacobian matrix. • Reset frequency. The number of major iterations after which the Hessian is reset to JTJ. In addition to the above parameters, the work arrays are checked for suitable sizing, and a summary of the Jacobian element estimations is given.14-55 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-56 Data Reconciliation Utility ww ThIteration Output On each major iteration, output is generated to detail the progress of the optimization algorithm in minimizing the DRU function. The output for each iteration is given under the iteration header, Major iteration n. The following list details the tabulated output produced; the heading is only produced for the first iteration. • Itn. The major iteration count. • ItQP. The sum of the iterations required by the feasibility and optimality phases of the QP problem (which generates the optimal step direction and length). Large values indicate difficulty in finding a new optimal point. • Step. The step, , taken along the computed search path. On a reasonably behaved problem, this tends to unity. • Nfun. The cumulative number of subfunctions needed for the linesearch (excluding finite difference calculations). This provides a guide on the amount of work performed in the linesearch. • Objective. This is the value of the objective function, which should decrease monotonically as the optimization progresses. This should not be confused with the objective function calculated upon termination of the DRU task. This value is also repeated after the table (with more significant figures). • Bnd. The number of simple bound constraints in the predicted active set. This is not applicable for the DRU task, and is always zero (after the first iteration). • Lin The number of linear constraints in the predicted active set. This is not applicable for the DRU task, and is always zero. • Nz. The number of variables less the number of constraints in the predicted active set. For an DRU task this is always the number of parameters or offsets being fitted. • Norm Gf. The Euclidean norm of the gradients of the objective function with respect to the free (unbounded) variables. • Norm Gz. The Euclidean norm of the projected gradient. This is approximately zero near the solution. • Cond H. The lower bound on the condition number of the Hessian approximation, H. • Cond Hz. The lower bound on the condition number of the projected Hessian approximation, Hz. The larger this number is, the more difficult the problem is to minimize. α 14-56 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-57 ww Th• Cond T. The lower bound on the condition number of the matrix of predicted active constraints. This is not relevant to the DRU application. • Conv. This is a three letter indication of the convergence test status. The letters indicate True or False. The letters detail the following points, in order: - sequence of iterates has converged - projected gradient (Norm Gz) is sufficiently small - constraint residual norm in the active set (Norm C) is sufficiently small (this is always true in the DRU application) The following letters may display at the end of an output line: For each major iteration, a section is produced detailing the “Values of the constraints and their predicted status”. The variables are listed in order, giving the value of the scaled variable (which is scaled internal to the optimization routine between -1 and +1), and its predicted status. For instance, if a parameter is allowed to vary in the model between 0 and 100, and lies at the model value of 25, the scaled value internal to the optimization routine would be -0.5. The predicted status is a binary number, zero indicating the variable is free, and one indicating the variable is at one of its bounds. Also produced are the diagonals of R, which are the triangulation factors of the transformed and re-ordered Hessian. Letter Description C Indicates the use of central difference approximation in the gradient evaluations. L Indicates that the linesearch produced a change in a variable greater than specified by STEP LIMIT. R Indicates that refactorization of the approximated Hessian is performed.14-57 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-58 Data Reconciliation Utility ww Th Final Output Upon termination of the optimization algorithm, whether successful or not, the final output is produced. The number of subfunction calls made by the optimization routine differs from that made by the DRU task, since DRU evaluates the subfunction outside of the optimization routine as part of its solution. The following details are written as final output from the optimization algorithm. • INFORM. This details the status of the algorithm solution. Zero indicates successful solution. • MAJITS. The number of major iterations performed. • NFUN. The total number of function evaluations performed during the optimization (excluding those needed for gradient estimations). • NGRAD. The number of function evaluations performed for gradient estimations. • Varbl. The name (V) and the index of the variable. • Value. The scaled value of variable V. • State. The status of the variable. FR indicates the variable is unbounded, LL indicates the variable is bounded at its lower limit, and UL indicates the variable is bounded at its upper limit. • Lower Bound. This is the value of the lower bound for the variable within the optimization routine. For DRU tasks this is always -1. • Upper Bound. This is the value of the upper bound for the variable within the optimization routine. For DRU tasks this is always +1. • Lagr Mult. This gives the Lagrangian multiplier of the variable, if the variable is bounded. The value is zero for a free variable, positive for a variable at its lower limit, and negative for a variable at its upper limit. • Residual. This is the difference between the variable and its NEAREST bound. The optimization routine termination code is printed and the final value of the (internal) objective function is displayed as the last output (this is not the same as displayed by DRU, since the optimization value is internally scaled).14-58 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-59 ww Th14.8 Derivative Utility The Derivative utility is a component of the HYSYS.RTO real- time optimization package available as a plug-in to the basic HYSYS software package. The Derivative utility is one of two utilities used by HYSYS.RTO to provide the primary interface between the flowsheet model and the solver. Their primary purpose is to collect appropriate optimization objects, which are then exposed to solvers to meet a defined solution criteria. Refer to the Aspen RTO Reference Guide for details concerning the use of this utility. This guide details all features and components related to the HYSYS real time optimization package. If your current HYSYS version does not support RTO, contact your local AspenTech representative for more details. To add the Derivative utility, refer to the section on Adding a Utility.14-59 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-60 Dynamic Depressuring ww Th14.9 Dynamic Depressuring In the process design of safe pressure relief systems9, a depressurization process reduces the pressure and the inventory of pressurized vessels. HYSYS Dynamic Depressuring Utility uses a rigorous dynamic model for the depressurizing process, allowing you to accurately capture the dynamic behavior of depressuring operations. To start the Dynamic Depressuring calculations, specify enough information in the utility, and click the Run button on the Dynamic Depressuring property view. If you want to stop the utility while it is calculating, click the Stop button. Figure 14.33 The dynamic depressuring utility does not require dynamics or other additional special licenses to run.14-60 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-61 ww ThThe entered data gets transferred to a subflowsheet of the depressuring system (one inlet stream and one vessel). It is this subflowsheet that is run in dynamics until the depressuring time is complete, and the system then returns to steady state. The results are retrieved from the strip charts, and displayed on the Performance tab. Dynamic Depressuring Subflowsheet The dynamic depressuring subflowsheet is not meant to be altered in any way. In fact, before the utility runs, HYSYS checks to see if the template has been changed (for example, if the number of streams and unit operations has change), and if it has been changed HYSYS deletes the altered subflowsheet and creates a new one. There are three spreadsheets in the subflowsheet: • vapour flow rate • liquid flow rate • duty Figure 14.34 The Dynamic Depressuring utility works with any fluid package, except for the electrolyte fluid package and where solids are present. To add the Dynamic Depressuring utility, refer to the section on Adding a Utility.14-61 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-62 Dynamic Depressuring ww ThThe three spreadsheets are used for the flow rate and heat flux equations. The calculated flows are exported from the spreadsheets to either the vapour, liquid, or duty stream flow. The Dynamic Depressuring utility provides an Use Spreadsheet option for both the liquid and vapour flow rate, and the heat flux equation. The Use Spreadsheet option gives unlimited possibilities of flow rate and heat flux equations. You can select the Use Spreadsheet option from the Operating Mode drop-down list on the Heat Flux page of the Design tab in the Dynamic Depressuring utility property view. When you select the Use Spreadsheet option, a View Spreadsheet button appears. By clicking the View Spreadsheet button, the corresponding spreadsheet opens to be modified. The flow rate spreadsheets are not always used. When a fisher valve or a relief valve is selected the standard unit operation is added to the subflowsheet. When the utility runs, the values of the variables for the selected equation are transferred to the spreadsheet. The spreadsheets are used to transfer data from the utility, which is manipulated and then sent to different unit operations. As a result the spreadsheet is being over written every time the utility runs. If you modify the spreadsheet and run the utility, your added information is lost. The only time a spreadsheet is not overwritten is when the Use Spreadsheet option/mode is selected. For more information regarding the equations that are used when either the fisher valve or relief valve is selected, refer to the section on Choosing the Valve Equation.14-62 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-63 ww ThOperation Modes The operation modes available in the Dynamic Depressuring operation are as follows: • Fire • Fire Stephan Boltzman • Fire API521 • Adiabatic • Use Spreadsheet You can view the results of the depressuring calculations in either tabular or graphical format. The four types of depressuring calculations available are as follows: The only time the values specified in a spreadsheet is not overwritten is when the Use Spreadsheet mode is selected. Calculation Description Fire Mode Used to simulate plant emergency conditions that occur during a plant fire. Pressure, temperature, and flow profiles are calculated for the application of an external heat source to a vessel, piping, or combination of items. Heat flux into the fluid is user defined. Do not specify a wetted area for this calculation. Fire Stephan Boltzman This mode includes radiation term, forced convection term, flame temperature, and ambient temperature term in the calculation. Fire API521 The same as Fire Mode except the heat flux into the fluid is calculated from the API equations for a fire to a liquid containing vessel. A wetted area for the vessel is required, and is used for heat transfer in the model.14-63 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-64 Dynamic Depressuring ww ThThe Dynamic Depressuring utility can be used to simulate the depressuring of gas, gas-liquid filled vessels, pipelines, and systems with depressuring through a single valve. References to “vessel” can also be “piping” or “combinations of the two.” 14.9.1 Design Tab The Design tab contains the following pages: • Connections • Config. Strip Charts • Heat Flux • Valve Parameters • Options • Operating Conditions • Notes Adiabatic Used to model the gas blow down of pressure vessels or piping. No external heat is applied. Heat flux between the vessel wall and the fluid is modeled as the fluid temperature drops due to the depressurization. The heat transfer coefficient is entered by the user, or can be calculated by HYSYS from the vessel fluid’s vapour properties. When estimated by HYSYS, the heat transfer coefficient is estimated from the “wetted” area and the vessel volume specified by the user. The “wetted area” specified should be equal to the total surface area of the vessel, not the area in contact with the liquid. Typical use of this mode is the depressuring of compressor loops on emergency shutdown. Use Spreadsheet If you change the mode from Use Spreadsheet to another mode, the spreadsheet is over written. Calculation Description Refer to Dynamic Depressuring Subflowsheet for more information on the Use Spreadsheet mode.14-64 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-65 ww ThConnections Page The Connections page allows you to specify the inlet stream, vessel volume, and initial liquid volume for the utility. • Name field enables you to change the name of the dynamic depressuring utility. • Inlets row enables you to enter or select up to four inlet streams for the utility. • In the Vessel Parameters group, you can select the vessel’s orientation using one of Orientation radio buttons (Horizontal or Vertical), and you can change the vessel surface area of the head for heat transfer calculations in the Heat Transfer Areas table. The parameters in the Correction Factors table are used to consider effects of the metal mass in contact with the liquid, and the metal mass in contact with the vapour. If you enter only one inlet stream in the Vessel Parameters group, you must enter a volume for the vessel, liquid volume, and the height or diameter of the vessel; or enter the liquid volume, height, and diameter of the vessel. HYSYS then calculates the missing information. Figure 14.35 Each stream has its own vessel volume and liquid volume.14-65 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-66 Dynamic Depressuring ww ThIf you enter more than one inlet stream, two rows appear underneath the Inlet row. The two rows are Vessel Volume and Liquid Volume. You can enter the vessel volume and the liquid volume for each stream in the associated Vessel Volume and Liquid Volume fields. Default values of the vessel parameters are calculated using a settle out calculation. The vessel/liquid volume fields are available for each inlet stream specified, and the fields are described in the section below. Vessel\Liquid Volume Fields For the stream selected for depressuring, HYSYS requires the vessel volume and the normal expected liquid volume of the vessel (in other words, at the normal liquid level). If the feed stream is two phase, the composition of the liquid is calculated from this. You must either specify the Height and Diameter, or the Flat End Vessel Volume. If you specify only the Flat End Vessel Volume, HYSYS automatically estimates the Height, Diameter, and Initial Liquid Volume. By specifying only the vessel volume, the liquid volume is calculated using Equation (14.5) and the remainder of the vessel is assumed to be filled with equilibrium vapour. For more than one stream, a settle out calculation is done. The results are approximate, because the settle out calculation is used in one vessel (like the Original Depressuring utility). Larger systems and more complex configurations can be studied in Dynamics mode, where the pipe networks and so forth, can be configured. (14.5) The Liquid Volume must be greater than 0 and less than the Flat End Vessel Volume. Liquid Volume Liquid Volume Flow of Liquid Phase 1× hour=14-66 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-67 ww ThIf you specify both the Initial Liquid Volume and Flat End Vessel Volume, then the head space is assumed to be filled with equilibrium vapour. Config. Strip Charts Page The Config. Strip Charts page allows you to add, modify, or delete strip charts, and select the variables you want to appear in each strip chart. Figure 14.36 You don’t have to create a strip chart, because the dynamic depressuring utility automatically creates a minimum required variable strip chart. When creating additional strip charts, ensure the select variables are from the correct depressuring subflowsheet.14-67 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-68 Dynamic Depressuring ww ThThe table below describes the objects available on the Config. Strip Charts page: Object Description Logger Name field The name of the selected strip chart on the list. You can change the name of the strip chart, by entering a new name in this field. Sample Interval field The length of time between data samples taken for the strip chart. The sample interval is set to equal the time step size specified on the Operating Conditions page of the Design tab. You have to run the Dynamic Depressuring utility calculations after the strip chart has been changed, or created in order to view the updated strip chart. List The list on the left side of the Logger Name field contains all the names of the strip charts associated with the current dynamic depressuring utility. You can manipulate the variables of strip charts by selecting the name of the strip chart on the list. Table Contains all the variables that can be stored in the strip chart. You can select, which variable you want to be stored in the strip chart during calculations by selecting the checkbox associated with the variable. Create Plot button Allows you to create a new strip chart. Click this button and a new strip chart appears in the list. The default name of the new strip chart is DataLogger. Delete Plot button Allows you to delete strip charts. Select the strip chart you want to delete from the list and click this button. This button is only available if there is a strip chart in the list. Add Variable button Allows you to enter a new variable in the strip chart. Select the strip chart you want the variable to appear in and click this button. The Variable Navigator property view appears, and you can select the variable you want to add from this property view. View Strip Chart button Allows you to view the strip chart. Select the strip chart you want to view from the list and click this button, the strip chart property view appears. Refer to Section 1.3.9 - Variable Navigator Property View for information.14-68 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-69 ww ThHeat Flux Page On the Heat Flux page, you can specify the depressuring mode and heat loss model for the utility. View Historical Data button Allows you to view the data points stored in the strip chart in table format. Select the strip chart you want to view from the list and click this button, the Historical Data property view appears. The Historical Data property view contains two buttons that allow you to save/export the results: • Save To CSV File • Save To DMP File Create Aspen Flare System Analyzer Plot button Allows you to create a strip chart that contains information you may want to export to Aspen Flare System Analyzer. Click this button to create the strip chart. The default name is the dynamic depressuring utility’s name followed by FLARENET. To add another FLARENET strip chart, change the default name of the previously created FLARENET strip chart before clicking the Create Aspen Flare System Analyzer Plot button again. You have to run the Dynamic Depressuring utility calculations after the strip chart has been changed, or created in order to view the updated strip chart. Figure 14.37 Object Description14-69 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-70 Dynamic Depressuring ww ThThe available choices for depressuring modes are as follows: • Fire Mode. When depressuring in Fire mode, five coefficients (C1 to C5) are required to set up the following generalized equation: where: t = Time, seconds T = Vessel temperature, °C Vt = Liquid volume at time = t Vo = Liquid volume at time = 0 As an example, you can model the standard heat transfer equation: By setting C1, C2, and C5 to zero. Set C3 to UA and C4 to the constant temperature in the term. • Fire API521 Mode. The Heat Flux Parameters page for depressuring in Fire API521mode is similar to the property view observed in Fire mode. Three coefficients C1 to C3 need to be specified to set up the following equation, which is an extension to the standard API equation for flux to a liquid-containing vessel. Depending on the version of HYSYS that you used to build the dynamic depressuring case, the heat flux is calculated differently. For HYSYS 3.1 or older version: (14.6) (14.7) The wetted area is required for the Fire API521. (14.8) Refer to Section - Operation Modes for a description of the available modes. Q C1 C2t C3 C4 T–( ) C5 Vt V0 -----⎝ ⎠ ⎛ ⎞+ + += Q UAΔT= ΔT Q C1 wetted area(time=t)[ ] C2⋅=14-70 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-71 ww ThFor current version of HYSYS: • Fire Stephan Boltzman Mode.The following equation is used for the Fire Stephan Boltzman mode. This equation includes a radiation term, forced convection term, flame temperature term, and ambient temperature term. where: Atotal = total surface area = flame emissivity where: (14.9) The units of the wetted area are controlled by the preferences, and not by the equation units. (14.10) Equation (14.10) uses a more rigorous method to calculate the wetted area by taking into account of the orientation of the depressuring vessel. In HYSYS 3.2 the depressuring utilities automatically use Equation (14.10) to calculate the heat flux. For cases that are built with HYSYS 3.1 or older version, when you re-run the depressuring utility in HYSYS 3.2 you have the option to calculate the heat flux using Equation (14.9) or Equation (14.10). However, once you selected Equation (14.10) and saved the case, you cannot re- calculate the heat flux using Equation (14.9). wetted area(time=t) wetted area(at time=0) 1 C3 1 LiqVol(time=t) LiqVol(time=0) ---------------------------------------–– ⎩ ⎭ ⎨ ⎬ ⎧ ⎫ ×= Q C1 C3 wetted area(time=t)⋅[ ] C2⋅= (14.11)Q Atotal k( εf Tf 273.15+( )4× εv Tv 273.15+( )4× ) OutsideU Tambient Tv–( )×+–( )××= εf14-71 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-72 Dynamic Depressuring ww Th = vessel emissivity k = Boltzman constant Tf = flame temperature Tv = vessel temperature OutsideU = convective heat transfer coefficient between vessel and surrounding air Tambient = ambient temperature • Adiabatic Mode. When Adiabatic mode is selected, heat flux information is not required. • Use Spreadsheet Mode. The Use Spreadsheet option refers to the duty spreadsheet of the Dynamic Depressuring utility used by the utility. This option allows you to edit the duty spreadsheet without the values in the spreadsheet getting overwritten when the utility runs. This option also allows the more advanced users the ability to use a different equation for the heat flux. When this option is selected, the View Spreadsheet button appears. Clicking the View Spreadsheet button opens the duty spreadsheet. Heat Loss Parameters Group The Heat Loss Model field contains a drop-down list, where you can select the heat loss model for the utility. There are three types of models: • None • Simple • Detailed εv14-72 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-73 ww ThSimple Model The Simple model allows you to either specify the heat loss directly, or have the heat loss calculated from specified values: • Overall U value • Ambient Temperature The heat transfer area, A, and the fluid temperature, Tf, are calculated by HYSYS. The heat loss is calculated using: The simple heat loss parameters are: • Overall Heat Transfer Coefficient • Ambient Temperature • Overall Heat Transfer Area • Heat Flow The Heat Flow is calculated as follows: where: U = overall heat transfer coefficient A = heat transfer area TAmb = ambient temperature T = holdup temperature As shown in Equation (14.13), Heat Flow is defined as the heat flowing into the vessel. The heat transfer area is calculated from the vessel geometry. Q = UA(Tf - Tamb) (14.12) Heat Flow = UA(TAmb - T) (14.13)14-73 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-74 Dynamic Depressuring ww ThThe overall heat transfer coefficient, U, and the ambient temperature, TAmb, can be modified from their default values (shown in blue and red in the figure below). Detailed Model The Detailed model allows you to specify more detailed heat transfer parameters. You can either apply the duty to the fluid inside the vessel or to the external surface of the vessel. When you select the Apply Duty Stream to Outside Wall checkbox, HYSYS applies the duty calculations to the external surface of the vessel. When you clear the Apply Duty Stream to Outside Wall checkbox, HYSYS applies the duty calculations to the fluid inside the vessel. When you select Detailed from the drop-down list, four radio buttons appear in the Heat Loss Parameters group. Figure 14.38 The value in the Heat Transfer Area display field is based on the vessel geometry you entered on the Connections page. Notice that the text is black, indicating the value in the field is calculated and cannot be changed on this page. Refer to Section 1.6 - HYSYS Dynamics in the HYSYS Dynamic Modeling guide for more information.14-74 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-75 ww ThRadio Button Description General Allows you to manipulate the Recycle efficiencies and Ambient temperature. In the Additional Heat Flux Injection field you can specify a heat flux value for the fluid contents in the vessel. The Recycle efficiency default values are 100%, which means that all phases are always in thermodynamic equilibrium, and hence all phases have the same temperature. If the efficiency values are reduced (to say 10%), then the vapor and liquid cannot reach equilibrium instantaneously and can have different temperatures. No single typical number can be suggested here, and you should try various scenarios for the possible temperature. Conduction Allows you to manipulate the conductive properties of the wall and insulation. In the Additional Heat Flux Injection field you can specify a heat flux value for the fluid contents in the vessel. You can specify the following properties: • Thickness of material. The insulation value thickness to be zero to model a vessel without insulation. The metal wall must have a finite thickness. • Specific Heat capacity of material • Density of material • Conductivity of material14-75 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-76 Dynamic Depressuring ww ThConvection Allows you to manipulate the heat transfer coefficient for inside and outside the vessel, and between vapour and liquid material inside the vessel. • Fixed U. Select this radio button if you want the U values, that you specified, to be used throughout the calculations. • Update U. Select this radio button if you want the U values calculated using the current conditions during the calculations (in other words, no user input.). The U values are updated while solving. Click the Estimate Coefficient button to estimate convective heat transfer coefficients (U value) using current conditions. Correlation Constants Allows you to manipulate the heat transfer correlation coefficients. • Auto Select Correlation Constants. Correlations constants are automatically selected based on the Grashof and Prandtl numbers. • Use Specified Constants. You can specify the C and m constants in Equation (14.14) for the outside heat transfer coefficient for air. The equation for outside heat transfer coefficient for air is: (14.14) All the other correlation are based on the equation below: where: Nu = Nusselt number Gr = Grashof number Pr = Prandtl number (14.15) Radio Button Description h C delta_Temperature length --------------------------------------------⎝ ⎠ ⎛ ⎞m ×= Nu C Gr Pr×( )m×=14-76 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-77 ww ThValve Parameters Page The Valve Parameters page allows you to select the type of valve equation you want to use for your vapour and liquid outlet streams. Click the Valve Equation Help button to open the Depressuring Valve Equation Help property view, which contains a summary of all the valve equations available for the Dynamic Depressuring utility. Choosing the Valve Equation You can select the Valve Equation from the Vapour/Liquid Flow Equation drop-down list. Figure 14.39 HYSYS recommends you use either the Fisher or Relief option to size the valve. The Fisher and Relief valve equations are more advanced than the other valve equations, and they can automatically handle choking conditions, and support various additional factors and options that can be accessed from the property views of the valve unit operation.14-77 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-78 Dynamic Depressuring ww ThYou have seven options for the valve equation, and they are listed in the following table: Use the Session Preferences property view to determine the units for the equation. Equation Description Fisher Uses a ‘Fisher’ valve (the standard valve in HYSYS). This option allows you to specify the Cv and % opening. You can calculate Cv for a given flow rate: 1. Click the Size Valve button located next to the Vapour Flow Equation field. Notice that the Size Valve button only appears if you select the Fisher option. The Vapour/Liquid Valve Sizing property view appears. 2. Enter valve sizing conditions, and select the valve type and solving method. 3. Click the Size Valve button in the Valve Type and Sizing Method group, and notice a new Sizing Flow Rate will be calculated. 4. Click the OK button to accept the new size and exit the property view, or click the Cancel button to exit the property view without changing the valve size. Refe to Section 6.7 - Valve for more information about valves. When sizing the valve, you have to enter a Sizing Valve Opening (%).14-78 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-79 ww ThRelief valve Uses the Relief valve operation in HYSYS. This option allows you to specify the orifice area, relief pressure, and full opening pressure. You have to enter the following variables: • Orifice Area/Orifice Diameter • Orifice Discharge Coefficient. As fluid exits a reservoir through a small hole and enters another one, or flows out to the open air, stream lines tend to contract itself, mostly because of inertia. The coefficient of discharge is used to include this effect. If you do not want to include the effect, enter C = 1. • Relief Pressure • Full Open Pressure. To have the relief valve open all the time, set the full open pressure lower than the final expected vessel pressure, and set its set (or relief) pressure slightly lower than the full open pressure. Supersonic (14.16) where: Cd = discharge coefficient (You can only enter values between 0 and 1 for the discharge coefficient.HYSYS recommends a value between 0.7 and 1 for the discharge coefficient.) A = area P1 = upstream pressure = upstream density Use the Supersonic equation for modeling systems when no detailed information is available on the valve. The flow through the valve is then proportional to A (area). Equation Description Refer to Section 6.5 - Relief Valve for more information about Relief valves. You can open the Relief Valve manually by clicking the Open Manually button. F CdA P1ρ1( )0.5= ρ114-79 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-80 Dynamic Depressuring ww ThSubsonic (14.17) where: Cd = discharge coefficient (You can only enter values between 0 and 1 for the discharge coefficient. HYSYS recommends a value between 0.7 and 1 for the discharge coefficient.) A = area P1 = upstream pressure Pback = back pressure or valve outlet pressure = upstream density If the pressure in the vessel is such that there is sub-critical flow (generally upstream pressure less than twice the backpressure), then you have no option but to use the Subsonic Equation. This equation is used in the same instances as the Supersonic equation except when you have subsonic flow. By applying this equation, you are required to specify Pback or the valve back pressure. By specifying Pback to be slightly less than the Relief Pressure, it is possible to have your depressuring analysis cycle between pressure build-up and relief. Ensure a reasonable pressure differential, and increase the number of pressure steps for the analysis. Masoneilan (14.18) where: C1 = 1.6663 (SI default) or 38.86 (Field default) You cannot change the value for C1. Cv = valve coefficient Cf = critical flow factor P1 = upstream pressure = upstream density Yf = y - 0.148 y3 (the max value of Yf is 1) y = expansion factor Taken from the Masoneilan catalogue, this equation can be used for general depressuring valves to flare. Often the Cv for a valve is known from vendor data so when Masoneilan is selected, the appropriate values for C1 and C2, are automatically set as well as the units. Equation Description F CdA P1 Pback+( ) P1 Pback–( ) P1 ------------------------------------------------------------- ρ1 0.5 = ρ1 F C1CvCfYf P1ρ1( )0.5= ρ114-80 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-81 ww ThOptions Page The Options page allows you to enter a value for the PV Work Term Contribution. The PV Work Term Contribution value is used to approximate the isentropic efficiency. Higher values result in lower pressures and temperatures, and the commonly used values range from 87% to 98%. General (14.19) where: Cd = discharge coefficient (You can only enter values between 0 and 1 for the discharge coefficient. HYSYS recommends a value between 0.7 and 1 for the discharge coefficient.) Av = valve orifice area gc = dimensionless constant = 1.0 kg.m/N.s2 (32.17 lb.ft/lbf.s 2) k = ratio of specific heats (Cp/Cv) P1 = upstream pressure = upstream density This equation is from Perry’s Chemical Engineering Handbook. Refer to it if you know the valve throat area. This equation makes certain limiting assumptions concerning the characteristics of the orifice. No Flow Indicates that there is no flow rate output in the valve. Use Spreadsheet The flow rate spreadsheet in the Dynamic Depressuring subflowsheet used by the utility. This option allows you to edit the spreadsheet without the changes made in the spreadsheet getting overwritten when the utility runs. This option also allows more advanced users to define a completely different equation for the flow. Figure 14.40 Equation Description F CdAvKterm gcP1ρ1k( )0.5= ρ114-81 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-82 Dynamic Depressuring ww ThOperating Conditions Page On the Operating Conditions page, you can specify what you want to solve (valve coefficient or pressure). The information required on this page varies, depending on the type of valve equation you selected for the vapour flow on the Valve Parameters page. The three specifications that apply to all valve equations are: HYSYS can solve either the valve coefficient or the pressure. Figure 14.41 Specification Description Operating Pressure Allows you to enter the initial vessel pressure. The default value is set to the pressure of the inlet stream. When the utility has multiple inlet streams, then only the operating pressure is calculated (settle out calculations). Time Step Size Allows you to specify the integration step size. The default value is 0.5 seconds. Helpful Tip: reduce the time step when you see a large flow rate compared to the volume. Depressuring Time The Depressuring Time is the time you want this operation to take. It is defaulted as 15 minutes (900 seconds) based on API 521, but you can alter this if required.14-82 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-83 ww ThThe table below describes the required specifications for each equation when you select the Calculate CV or Calculate Pressure radio button. The Dynamics Depressuring utility runs the dynamics integrator. The integrator uses a fixed integration step size with a default value of 0.5 seconds, and always runs for the total depressuring time specified. If your vessel depressurizes in relatively short time (for example 3 seconds), you may need to decrease the integration step size and depressuring time appropriately. The sampling frequency of the strip chart is automatically set to the value of the Time Step Size. Valve Equation Required Specification(s) Calculate CV Calculate Pressure Fisher/ Masonelian • Initial Cv Estimate • Max Cv Step Size • Pressure Tolerance • Maximum number of Iterations • Iteration Count • Final Pressure. Based on API, it is normal to depressure to 50% of the starting pressure or to 100 psig (6.89 barg). If the depressuring time is reached (for API 521, 15 minutes) before the final pressure is achieved, then calculations stop. The final pressure is used to calculate Cv for the vapour outlet stream. • Cv14-83 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-84 Dynamic Depressuring ww ThNotes Page The Notes page provides a text editor, where you can record any comments or information regarding the utility, or to your simulation case in general. 14.9.2 Worksheet Tab The Worksheet tab contains a summary of the information contained in the stream property view for all the streams attached to the operation. Relief • Initial Orifice Area Estimate • Max Area Step Size • Pressure Tolerance • Maximum number of Iterations • Iteration Count • Final Pressure. Based on API, it is normal to depressure to 50% of the starting pressure or to 100 psig (6.89 barg). If the depressuring time is reached (for API 521, 15 minutes) before the final pressure is achieved, then calculations stop. The final pressure is used to calculate the orifice area for the vapour outlet stream. • Orifice Area Supersonic/ Subsonic/ General • Initial Area Estimate • Max Area Step Size • Pressure Tolerance • Maximum number of Iterations • Iteration Count • Final Pressure. Based on API, it is normal to depressure to 50% of the starting pressure or to 100 psig (6.89 barg). If the depressuring time is reached (for API 521, 15 minutes) before the final pressure is achieved, then calculations stop. The final pressure is used to calculate area for the vapour outlet stream. • Area Valve Equation Required Specification(s) Calculate CV Calculate Pressure For more information, refer to Section 1.3.5 - Notes Page/Tab. Refer to the Section 1.3.10 - Worksheet Tab for more information.14-84 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-85 ww Th14.9.3 Performance Tab The Performance tab contains the following pages: • Summary • Strip Charts Summary Page The Summary page contains a summary of all the calculated results. Figure 14.4214-85 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-86 Dynamic Depressuring ww ThStrip Charts Page The Strip Charts page allows you to view the results in tabular or graphical format. The page contains five buttons: • Create Plot. Generates a strip chart. • Delete Plot. Allows you to delete a strip chart. • Add Variable. Allows you to add the strip chart variables. • View Strip Chart. Allows you to open and view the strip chart. • View Historical Data. Allows you to open and view the historical data. The Historical Data property view contains two buttons that allow you to save/export the results: Save To CSV File and Save To DMP File. • Create Aspen Flare System Analyzer Plot. Allows you to generate a Aspen Flare System Analyzer strip chart. Figure 14.43 The Strip Charts page allows you easy access to the strip charts and the historical data. Refer to Section 1.3.9 - Variable Navigator Property View for information.14-86 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-87 ww Th14.10 Envelope Utility The Envelope utility allows you to examine relationships between selected parameters for any two-phase or three-phase stream of known composition, including streams with only one component. 14.10.1 HYSYS Two-Phase Envelope The Vapour-Liquid Envelopes can be plotted for the following variables: • Pressure-Temperature • Pressure-Volume • Pressure-Enthalpy • Pressure-Entropy • Temperature-Volume • Temperature-Enthalpy • Temperature-Entropy For the Pressure-Temperature envelope, quality lines, and a hydrate curve can also be added to the plot. The remaining curves allow the inclusion of Isocurves (Isotherms or Isobars). Since the Envelope is calculated on a dry basis, you must be careful when applying the utility to multi-component mixtures that contain H2O or any other component which can form a second liquid phase. The Envelope utility is restricted to the Peng Robinson and Soave Redlich Kwong equations of state. To add the Envelope utility, refer to the section on Adding a Utility.14-87 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-88 Envelope Utility ww ThDesign Tab The Design tab contains the following pages: • Connections • Notes Connections Page On the Connections page, you can select the HYSYS Two-Phase envelope utility and attach it to a stream. The Connections page also displays, the calculated critical temperature and pressure, as well as the cricondentherm and cricondenbar. You can change the name of the envelope utility by typing in the Name field. The stream is chosen from the Select Process Stream property view, which is accessed by clicking the Select Stream button. Notes Page The Notes page provides a text editor, where you can record any comments or information regarding the utility, or to your simulation case in general. Figure 14.44 Select the HYSYS Two-Phase envelope utility from the drop- down list. For more information, refer to Section 1.3.5 - Notes Page/Tab.14-88 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-89 ww ThPerformance Tab The Performance tab contains the following pages: • Plots • Table Plots Page On the Plots page, you can display different types of envelope graphs depending on the selected radio button in the Envelope Type group. The following sections discuss the various available envelopes in more detail. Figure 14.45 You can clear all curves on the plot at any time by clicking the Clear button.14-89 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-90 Envelope Utility ww ThPressure-Temperature Envelope When you select the PT radio button in the Envelope Type group, the Vapour-Liquid Envelope for a quality of 1.0 automatically appears. This is actually represented by two curves; one with a vapour fraction of 1.0 and the other having a liquid fraction of 1.0. These curves meet at the stream critical point. You can plot additional envelopes for different qualities simply by typing the desired quality (between 0 and 1) in the Quality 1 and Quality 2 fields. Select the Hydrate checkbox to have HYSYS calculate and display the hydrate temperature curve for pressures up to the cricondenbar. When you select the Hydrate checkbox, you can select from the drop-down list the model (Assume Free Water, Asymmetric, Symmetric or Vapour Phase Only) to perform the Hydrate Formation calculations. Figure 14.46 The plot on the right, shows an envelope for a quality of 0.9. A quality of 0.9 is represented by two curves; one with a vapour fraction of 0.9 and the other having a liquid fraction of 0.9. For more information on the Hydrate calculation models, refer to Section 14.12 - Hydrate Formation Utility.14-90 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-91 ww ThPV-PH-PS Envelopes If you select the PV radio button, the Pressure-Volume Envelope appears. If you select the PH radio button, the Pressure- Enthalpy Envelope appears. If you select the PS radio button, the Pressure-Entropy Envelope appears. For each of these Envelopes, you can display a maximum of three Isotherms (constant temperature curves) by entering values in the Curves group. The figure below shows the Pressure-Enthalpy Envelope for a stream, with 106°C and 142°C Isotherms. TV-TH-TS Envelopes If you select the TV radio button, the Temperature-Volume Envelope appears. If you select the TH radio button, the Temperature-Enthalpy Envelope appears. If you select the TS radio button, the Temperature-Entropy Envelope appears. For each of these Envelopes, you can display up to three Isobars (constant pressure curves). Simply, enter the desired pressure(s) in the Curves group. Figure 14.4714-91 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-92 Envelope Utility ww ThThe figure below shows the Temperature-Entropy envelope for a stream, with a 2068 kPa Isobar. Table Page You can view the envelope results in tabular format on the Table page. To view the tabular results of different envelopes, from the Table Type drop-down list select the table type for the data. All Isocurves and Quality lines associated with the individual envelopes are transferred to the table. Figure 14.48 Just like the Clear button in the Plots page, you can clear all curves data at any time by clicking the Clear button in the Table page.14-92 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-93 ww ThDynamics Tab The Dynamics tab allows you to control how often the utility gets calculated when running in Dynamic mode. The Control Period field is used to specify the frequency that the utility is calculated. A value of 10 indicates that the utility be recalculated every 10th pressure flow step. This can help speed up your dynamic simulation since utilities can require some time to calculate. The Use Default Periods checkbox allows you to set the control period of one utility to equal the control period of any other utilities that you have in the simulation. For example, if you have five utilities and require them all to have a control period of 5 and currently the value is 8, with this checkbox selected if you change the value in one utility all the other utilities change. Alternatively, if you want all the utilities to have different values you would clear this checkbox. The Enable in Dynamics checkbox is used to activate this feature for use in Dynamic mode. Figure 14.4914-93 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-94 Envelope Utility ww Th14.10.2 Three-phase Envelope Utility The three-phase envelope utility allows you to examine the relationships between selected parameters, for any stream of known composition, including streams with components that can potentially form a second liquid phase (for example, water, methanol, H2S, and so forth). Vapour-Liquid, Liquid-Liquid, and Vapour-Liquid-Liquid envelopes can be plotted for the following variables: • Pressure-Temperature • Pressure-Volume • Pressure-Enthalpy • Pressure-Entropy • Temperature-Volume • Temperature-Enthalpy • Temperature-Entropy The three-phase envelope is designed for the use in the oil and gas industries, which deal primarily with water, alcohols, hydrocarbon and sour gas components, and use an equation-of- state to model their fluid systems. The three-phase envelope utility can be used for a wide variety of systems and property packages. It is recommended that you ignore the three-phase envelope utility during calculation, as the utility may be slow in calculating phase envelopes of streams containing a large number of components. You can select the Ignored checkbox on the utility’s property view to ignore this utility during calculations.14-94 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-95 ww ThDesign Tab The Design tab contains the following pages: • Connections • Notes You can select COMThermo Three-Phase from the drop-down list. Figure 14.50 Select the COMThermo Three-Phase utility from the drop- down list. Refer to Section 14.2.1 - Design Tab for more information on the Connections and Notes page.14-95 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-96 Envelope Utility ww ThPerformance Tab The Performance tab contains the following pages: • Plots • Table Plots Page The Plots page allows you to display different types of envelope graphs depending on the selected radio button in the Envelope Type group. Figure 14.5114-96 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-97 ww ThThe following types of points are supported in the three-phase envelope utility: The following sections discuss the various available envelopes in more detail. Pressure-Temperature Envelope When you select the PT radio button in the Envelope Type group, the Vapour-Liquid, Liquid-Liquid or Vapour-Liquid-Liquid envelopes automatically appears. The following are the various scenarios possible: Type of Point Description Two-phase Dew Line 1 Liquid 1 incipient Two-phase Dew Line 2 Liquid 2 incipient Two-phase Bubble Line Vapour incipient Two-phase Liquid-Liquid Line Liquid 1 or Liquid 2 incipient Two-phase Critical Point Vapour/Liquid critical on two-phase line Two-phase Cricondentherm Maximum Temperature Point Two-phase Cricondenbar Maximum Pressure Point Three-phase Point Vapour/Liquid or Liquid/Liquid incipient Three-phase Critical Point Vapour/Liquid or Liquid/Liquid incipient Three-phase Tri-Critical Point Vapour, Liquid 1 & Liquid 2 all critical Three-phase Bubble Line Vapour incipient Three-phase Incipient Liquid Line 1 Liquid 1 incipient Three-phase Incipient Liquid Line 2 Liquid 2 incipient The plots in this manual were created using the COMThermo HYSYSPR property package. Aspen Technology recommends this property package for use with three-phase envelope calculations.14-97 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-98 Envelope Utility ww ThInstability on the Two-phase Bubble Line This scenario results in envelopes that exhibit a two-phase dew line and a two-phase bubble line that intersect at a critical point. A three-phase point is found on the two-phase bubble line from which emerge three branches. These include the three-phase bubble line where the vapour phase is incipient, a three-phase incipient liquid line where the liquid phase is incipient and the two-phase liquid-liquid line where one of the liquid phases is incipient. This is common when a second liquid forming component such as H2O is present along with some heavy hydrocarbons (>C7). An equimolar mixture of o-xylene, p- xylene, H2S and H2O exhibit this behavior as shown below: Figure 14.5214-98 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-99 ww ThInstability on the Two-phase Dew Line This scenario results in envelopes, which exhibit two, two-phase dew lines which intersect at a three-phase point. From the three-phase point emerge two three-phase branches where each of the liquids is incipient. There is also a three-phase bubble line that intersects one of the incipient liquid lines at the three-phase critical point. An example of this scenario is shown in a methane, n-decane and water mixture shown below: Figure 14.5314-99 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-100 Envelope Utility ww ThInstability on both the Two-phase Dew and the Two- phase Bubble Lines This scenario results in envelopes, which exhibit two, two-phase dew lines which intersect at a three-phase point. From the three-phase point emerge two three-phase branches where each of the liquids is incipient. It also exhibits a two-phase dew line and a two-phase bubble line that intersect at a critical point. A three-phase point is found on the two-phase bubble line from which emerge three branches. These include the three-phase bubble line where the vapour phase is incipient, a three-phase incipient liquid line where the liquid phase is incipient and the two-phase liquid-liquid line where one of the liquid phases is incipient. This is common when the amount of second liquid forming component such as water is present in small amounts along with hydrocarbon components. An equimolar mixture of C1, C3 and CO2 with a small amount of H2O exhibit this behavior as shown below: Figure 14.5414-100 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-101 ww ThNon-Instability on the Two-phase Dew or the Two-phase Bubble Lines This results is several sub-scenarios as follows: • No three-phase region present. This scenario exhibits the regular two-phase envelope with no three-phase region. The two-phase bubble and two-phase dew lines intersect at a critical point. This is common where there is no second liquid forming components in the system. An equimolar mixture of C1, C2, C3, and n-C4 exhibit this behavior as show below: • Three-phase region present along with three- phase critical point but no two-phase critical point. This scenario exhibits a two-phase dew line without a critical point found on it. A three-phase region is present that is bounded by a three-phase bubble line and a three-phase incipient liquid line. The incipient vapour and incipient liquid are critical at the three-phase critical point. This is common when a second liquid forming component such as H2O is present along with light hydrocarbons ( . The message Ice Forms First indicates that ice will form before the formation of hydrates at that condition. Exceptions are for the two equilibrium points, where ice and hydrates coexist: • the quadruple point (ice-aqueous-vapour-hydrate equilibrium) • the quintuple point (ice-aqueous-vapour-liquid-hydrate equilibrium) When Aspen HYSYS cases containing Hydrate Formation utilities (without the override specification) are loaded from previous versions, the default calculation method is automatically selected and is used for hydrate predictions in the current version. If you want to have control over the model selection (namely Assume Free Water, Asymmetric Model, Symmetric Model, or Vapour Only Model), you can override the model by accessing the Model Override page and then selecting the desired model.14-133 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-134 Hydrate Formation Utility ww Th14.12.1 Design Tab The Design tab contains the following pages: • Connections • Model Override • Notes Connections Page On the Connections page, you can connect a stream to the Hydrate Formation utility and change the utility’s name. Click the Select Stream button to open the Select Process Stream property view. On the Select Process Stream property view, you can select the stream you want to be connected to the utility. Figure 14.7714-134 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-135 ww ThThe Hydrate Formation status at the current stream conditions are also shown on the Connections page. Hydrate Formation Status Description Hydrate Formation Flag Displays the status of hydrate formation. There are two possibilities: • Will Form • Will NOT Form Hydrate Type Formed Displays the types of Hydrate formed (Type I, Type II, Type I & II, Type H, Type I & H, Type II & H, or Type I & II & H). It is possible that Ice forms first, in which case HYSYS displays the message Ice Forms First in this field. If the stream temperature is higher than the formation temperature, then No Types is displayed in this field. Calculation Mode Possibilities are Use 2-Phase Model, Use 3-Phase Model, Use SH Model, and Assume Free Water. Inhibitor Calculation Possibilities are Included and Not Included.14-135 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-136 Hydrate Formation Utility ww ThModel Override Page The Model Override page allows you to gain control over a specific model for hydrate predictions. You can override the default model by selecting the Override Default Model checkbox and selecting an appropriate model for hydrate calculations as shown in the following figure. Notes Page The Notes page provides a text editor where you can record any comments or information regarding the utility or to your simulation case in general. Figure 14.78 For more information, refer to Section 1.3.5 - Notes Page/Tab.14-136 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-137 ww Th14.12.2 Performance Tab The Performance tab contains one page, Formation T/P. The Formation T/P page contains two groups: • Formation Temperature at Stream Pressure • Formation Pressure at Stream Temperature Formation Temperature at Stream Pressure Group The Formation Temperature at Stream Pressure group displays the formation temperature at which hydrates are formed at the stream pressure. The hydrate type formed at this formation temperature and the calculation mode are also shown. In addition, information on equilibrium phases that exist at the predicted formation temperature and notification of the inhibitor calculation are also displayed. The Equilibrium Phases field can be V-H, Aq-H, L-H, V-Aq-H, V-L- H, Aq-L-H, or V-Aq-L-H (where V, Aq, L, and H refer to vapour, aqueous, non-aqueous liquid, and hydrate phases, respectively). Refer to the Hydrate Inhibition section for a detailed description of the inhibitor calculation information. Figure 14.79 The hydrate types and calculation models are discussed in the Hydrate Calculation Models section.14-137 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-138 Hydrate Formation Utility ww ThFormation Pressure at Stream Temperature Group The Formation Pressure at Stream Temperature group displays the formation pressure at which hydrates are formed at the stream temperature. Similar to the Formation Temperature at Stream Pressure Group, this group shows • the hydrate type formed • the equilibrium phases at the predicted formation pressure • the calculation mode used • the notification of the inhibitor calculation Unlike the Performance tab, information on the equilibrium phases is not available in the Design tab. This is because the actual phase equilibrium at the given stream condition (with both stream pressure and temperature fixed) could be different from the phase equilibrium predicted at the condition where only the stream pressure or temperature is fixed. Information on the actual phase equilibrium at the given stream condition might be derived from the stream flash calculation. Hydrate Inhibition To avoid or inhibit the formation of hydrates, you can do one of the following: • Set the operating conditions to be outside the predicted equilibrium curve for hydrates (in other words, set the operating temperature to be higher than the hydrate formation temperature) • Inject inhibitors such as glycols (for example, EG, DEG, TEG) or alcohols (for example, methanol) to suppress the formation of hydrates. The inhibitors serve as antifreeze agents and depress the freezing conditions of hydrates. The hydrate types and calculation models are discussed in the Hydrate Calculation Models section.14-138 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-139 ww ThTo inhibit the formation of hydrates of a given stream in the flowsheet, you must install a stream containing the inhibitors. We recommend that you create an inhibitor stream which contains the inhibitor solution (for example, 30 weight% of methanol in water) and then use the Mixer operation to mix the inhibitor stream with the process stream to create a new stream which contains the desired amount of the inhibitor. You then can access the Hydrate Formation utility to find the new solid hydrate formation condition of the new stream. Due to the limitation of the models used, a high concentration of inhibitors is not recommended in the hydrate prediction (for example, the methanol concentration should not exceed 50 weight% with respect to water content when the given stream consists of methane11). The inhibitor model that Aspen HYSYS uses was developed using available experimental data obtained at the saturated water condition for the Structures I and II. At the saturated water condition, a free-water (aqueous) phase must exist. Therefore, Aspen HYSYS performs inhibition calculations only when there is an aqueous phase after an equilibrium flash. You must ensure that the stream of interest has sufficient amount of water to be at a saturated water condition. This inhibitor model is also applied to the Structure H hydrate. However, since there is no experimental data available for the inhibition using alcohols and glycols on the Structure H hydrate, the accuracy of this model cannot be ascertained. Use it with care and only to provide a rough estimate. Using the Assume Free Water model is not applicable here because the inhibitor calculation is not included in this calculation mode/model. Additionally, due to the limitation of the experimental data, the inhibitor calculation is not included when the 2-Phase model is used (either as determined by the Default model or specified using Model Override). Since three phase thermodynamics are used to perform the flash calculation, the phase distribution of the components, including water and the inhibitors, can be calculated rigorously. Therefore, inhibitor losses in the hydrocarbon liquid and vapour phases are properly taken into account.14-139 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-140 Hydrate Formation Utility ww ThThe Peng-Robinson (PR) equation of state was not originally designed for non-ideal components such as methanol and glycols. You should ensure the resulting distribution of the components in all phases is satisfactory, especially if three phases exist. The solubility of methanol in the hydrocarbon and aqueous phases is optimized with the PR equation of state for the methanol-HC-water VLE. Make further adjustment to the PR interaction parameters to meet your own specifications. Overall, this approach should be more accurate than using Hammerschmidt's equation which was developed specifically for dilute solutions of antifreeze agents. The Hammerschmidt equation applies only for typical natural gas mixtures and for solute concentrations less than 20 mole per cent. Although it is applied for cases beyond this region with reasonable success, this is attributed to a number of compensating factors. For validation of this model, refer to GPA Research Report RR-66. 14.12.3 Dynamics Tab The Dynamics tab allows you control how often the utility gets calculated when running in Dynamic mode. The Control Period field is used to specify the frequency that the utility is calculated. A value of 10 indicates that the utility is recalculated every 10th pressure flow step. This helps speed up your dynamic simulation since utilities could require some time to calculate. Figure 14.8014-140 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-141 ww ThThe Use Default Periods checkbox lets you set the control period of one utility to equal the control period of any other utilities that you have in the simulation. For example, if you have five utilities and require them all to have a control period of 5 and currently the value is 8, with this checkbox selected if you change the value in one utility all the other utilities change. Alternatively, if you want all the utilities to have different values, then clear this checkbox. The Enable in Dynamics checkbox is used to activate this feature for use in Dynamic mode.14-141 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-142 Master Phase Envelope Utility ww Th14.13 Master Phase Envelope Utility The Master Phase Envelope Utility allows you to calculate the three-phase envelope for multiples streams of known compositions, including streams with only one component. 14.13.1 Design Tab The Design tab contains the following pages: • Connections • Notes Connections Page The Connections page allows you to do the following: • Rename the utility by typing the new name in the Name field. • Add a stream by clicking the Add Stream button to open the Select Process Stream property view. • Remove a stream by selecting the stream and clicking the Remove Stream button. • Rearrange the order of the streams by clicking the Order Streams... button. In the Order Streams property view that appears, click the individual stream and then the Add or Remove button to arrange streams in the new list. Notes Page The Notes page provides a text editor, where you can record any comments or information regarding the utility, or to your simulation case in general. For more information, refer to Section 1.3.5 - Notes Page/Tab.14-142 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-143 ww Th14.13.2 Performance Tab The Performance tab contains the following pages: • Table • Plots Table Page You can view the envelope results in tabular format on the Table page. To view the tabular results of different envelopes for the desired stream, select a stream from the Stream drop-down list then select a table type from the Table Type drop-down list. All Isocurves and Quality lines associated with the individual envelopes are transferred to the table. Figure 14.81 The Table page allows you to display the envelope results for one stream at a time. Stream drop-down list Table Type drop-down list14-143 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-144 Master Phase Envelope Utility ww ThPlots Page The Plots page allows you to display different types of envelope graphs for multiple streams. You can plot the envelope graphs for the desired stream(s) by clicking the Select Streams To Plot radio button. All the streams that have been attached to the utility are listed in the table. Click the Plot radio button to plot the selected streams. Depending on the radio button selected, the vapour-liquid, liquid-liquid, and vapour-liquid-liquid envelopes can be plotted for the following variables: • Pressure-Temperature • Pressure-Volume • Pressure-Enthalpy • Pressure-Entropy • Temperature-Volume • Temperature-Enthalpy • Temperature-Entropy Figure 14.8214-144 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-145 ww Th14.14 Parametric Utility The Parametric Utility enables you to create neural networks to replace portions of the simulation flowsheet. You can now easily configure the utility to capture data from the flowsheet model. You can define a list of variables that you want to perturb (manipulated variables), and variables you want to record (observable variables). The utility allows you to quickly create lists of variables and to re-use variable lists. The data generated can be exported in a comma-delimited style in a number of different formats. The utility originated as a set of tools for building a Parametric model (PM) within the HYSYS environment. The utility integrates Neural Network (NN) technology into its framework. The major function of the Parametric utility is to approximate an existing HYSYS model with a Parametric model. Using a Parametric model with neural network capability to approximate a HYSYS model significantly improves the robustness of the model, and reduces its calculation time thereby improving overall performance. The accuracy of the model depends upon the data available, and the type of model being approximated. The object of analysis can be a collection of unit operations, an entire flowsheet, or a number of selected variables. Using input and output data sets as training data, the neural network algorithm determines the Parametric model parameters. This step is called training but can also be referred to as regression or identification. Steps one to four describe the general procedure for the Utility: 1. Select scope. 2. Select variables (manipulated and observable). 3. Define test datasets. 4. Generate data.14-145 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-146 Parametric Utility ww ThSteps five to six describe the general procedure to use for NN: 5. Train. 6. Validate. The Parametric Utility main purpose is to generate data and training for Neural Networks. This includes setting up the utility, and generating the data with some additional steps used in building the NN. 14.14.1 Neural Networks What is a Neural Network? A Neural Network (strictly ‘Artificial Neural Network’ as opposed to a ‘Biological Neural Network’) is a mathematical system with a structure based on the brains of mammals. The Artificial Neural Network is split into many basic elements (equivalent to neurons in biological systems), which are linked by synapses. Neural Networks model the relationship between input and output data. They are particularly suited to the kind of problems that are too complex for traditional algorithm based modeling techniques, for example pattern recognition and data forecasting. There are a number of types of Neural Networks, but HYSYS uses a Multi-Layer Perceptron (MLP) type model. The Neural Network is trained through a learning process where synaptic connections between neurons are constructed and weighted. The Neural Network is trained in an iterative manner. A set of input data and desired output data is repeatedly supplied, and based on the errors between the Neural Network calculated outputs and the desired outputs, the connections are adjusted for the next iteration.14-146 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-147 ww ThNeural Networks in HYSYS Neural Networks provide a performance and cost effective modeling tool, and can extend the capabilities of traditional statistics, modeling, and control. They can be applied in both linear and non-linear systems where first-principles modeling is too costly or difficult. Neural Networks provide flexible and powerful techniques for data analysis, and can be used for: • dynamic and static process modeling • nonlinear and adaptive control • inferential predictions • time series prediction • multivariate pattern recognition HYSYS includes a Neural Network calculation tool that can be used to approximate part (or all) of a HYSYS model. It can be trained to replace either the first principles calculations usually done by HYSYS, or to simulate a unit operation that cannot be modelled using the first principles. Using a Neural Network solver offers a number of advantages: • It is significantly faster that a first principles solution. • It offers increased robustness so that a result will always be possible. There are three parts to the HYSYS Neural Network implementation: • Parametric Utility. Where the Neural Network is configured and trained. • Parametric Unit Operation. Allows the Neural Network to appear as a unit operation on the flowsheet, and it is typically used when taking a “black box” approach. • Neural Network Manager. Allows you to switch Neural Network (NN) Objects into appropriately configured Parametric Utilities, and to generate simple Neural Network’s from external data. When using a Neural Network, always be aware that results are valid only within the range over which the Neural Network was trained. Refer to Section 14.14.4 - Neural Network (NN) Manager for more information on the Neural Network Manager.14-147 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-148 Parametric Utility ww Th14.14.2 Variables The parameters of the Parametric model are determined either through HYSYS simulation runs or based on historical plant data (the latter also requires the use of the Parametric unit operation). There are three types of variables: • Observable • Manipulated • Training The variables are discussed in the following sections. Observable Variables Observable variables can be either input or output variables within the HYSYS PFD model. When HYSYS is used to generate training datasets for the Parametric model, a number of simulation runs must be performed. During the simulation run, the simulation solution engine calculates each operation in the HYSYS PFD. The observable variables are the HYSYS variables whose values are known, and used as training data when calculating the Parametric model. Manipulated Variables Manipulated variables are the variables being modified in the Parametric utility, and are obtained from the HYSYS PFD model simulation. Observable input and output variables can each include both input and output stream variables. A HYSYS model parameter with a varying value can be either an observable input variable or an observable output variable within the Parametric model. Refer to Section 5.6 - Parametric Unit Operation for details on the Parametric unit operation.14-148 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-149 ww ThTraining Variables Training variables are a combination of both the observable and manipulated variables used to develop the Parametric model. The term “training” refers to the task of using the data sets available as a form of “learning” that, in effect, fits the model parameters to the specifications. The Parametric model approximates the HYSYS model in the sense that, given the same values for the training input variables, the values of the output variables from the Parametric model must be close to the values of the output variables from the HYSYS model. There are no methods for training neural networks that can “create” information that is not contained in the training data. The neural network model is only as good as its training data. 14.14.3 PM Utility Property View The PM Utility property view is composed of several tabs that are described in the following sections. The status bar at the bottom of the screen provides you with hints and descriptions of what the fields represent. To add the Parametric Utility, refer to the section on Adding a Utility.14-149 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-150 Parametric Utility ww ThConfiguration Tab The Configuration allows you to specify the name of the utility, calculation options, and select HYSYS objects to be included in the Parametric model. The Configuration tab defines the scope of the utility and lists the equipment from which you can select objects to configure. Once objects have been added to the final list, you must click the Accept List button and then click the Next button to proceed. Figure 14.8314-150 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-151 ww ThThere are two Calculation Options available which are described below: The Accept List button accepts the changes and obtains all variables known to the selected objects from the HYSYS flowsheet. Calculation Options Description Embedded into HYSYS Flowsheet This checkbox allows the trained neural network to replace the traditional HYSYS solver for the objects included in the NN. Advanced option mode This checkbox enables more flexibility in the selection of manipulated variable sets. If selected, the Embedding option checkboxes are displayed. • Intelligent Embed - For embedding, it is required that the stream variables selected are a flashable set. If checked, and the streams are over- specified, the utility does not query the user and selects a sub-set of variables that allows the streams to flash. If the streams are under- specified, the utility will not warn the user. • Initial Query Only - The above queries occur only once on the initial embedding unless the PMUtil configuration is changed. • Range Check - If the manipulated variable values are outside the range than the Neural Network in the Parametric Utility was trained upon, then the Parametric Utility is unembedded. You cannot advance to the next tab (Select Variables) unless you click the Accept List button.14-151 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-152 Parametric Utility ww ThSelect Variables Tab The Select Variables tab allows you to filter your objects so that you can add manipulated and observable variables. The various functions on this tab are described below. When you select the Manipulated radio button, a group of radio buttons become available for you to select a filter type from. This is to help you choose your manipulated and observable variables: • All. Shows all chosen variables of the selected type in the table. If you didn’t choose any, none will appear. • Object Filter. Shows a list of unit operations and objects in a tree browser for selection. • FlowSheet Filter. Shows a list of subflowsheets contained in the case and any related variables. • Variable Filter. Shows all flowsheet variables. Figure 14.84 The Property Filter radio button only appears if the Observable radio button is selected.14-152 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-153 ww ThThe table below describes the available objects on the Select Variables tab. The following buttons/radio buttons/fields are not always visible. Certain ones appear when the Manipulated or Observable radio buttons are selected, and others appear when you click the Change/Accept Configuration button. Object Description Build Streams button Builds variables based on the stream information in the utility scope. It selects all variables that can be modified in the streams as Manipulated variables and all stream variables as Observable Variables (often duplicating). If you have already created a set of variables, you must click the Change Configuration button to see this button. Remove All button Removes all variables from the table. If you have already created a set of variables, you must click the Change Configuration button to see this button. Build Flashable Streams button Selects all variables in the streams that can be modified and sets them as manipulated. For observable variables, it takes as many variables as necessary from the streams to flash without a inconsistency error. The flash used is a T/P/F flash. Display Mode group The group contains two radio buttons to choose from: • Configuration • All The radio buttons control how many columns appear in the variables table, and what type of data is displayed. Build Filter button Allows you to create a filter that adds all objects in the utilities scope that match your filter criteria. For example, if you want every stream temperature, pressure, and volume flow, you can build a filter to add all streams with these three variables. You can save and reuse these filters. If you have already created a set of variables, click the Change Configuration button to see this button. Apply Filter button Once a filter is built, click this button to add all variables that meet the filter criteria. Click the Change Configuration button to see this button.14-153 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-154 Parametric Utility ww ThWhen you are satisfied with your selection of observable and manipulated variables, click the Accept Configuration button. The current variable configuration is accepted, and you can now access the Data tab. Change/Accept Configuration buttons You must click the Change Configuration button when you want to change pre-selected variables. The Change Configuration button then becomes the Accept Configuration button. Any new changes will be updated when you click the Accept Configuration button. Range field If you change the Range, then the Low Limit/High Limit of the Manipulated Variables changes. For example, a value of 0.1 gives you a Low-High of . The Low Limit and High Limit are max/min used when generating random values for the manipulated variables on the Data tab. This is important when you want to randomly select the manipulated variables commonly applied with neural networks. This field is only visible when the Manipulated radio button is selected. Manipulated radio button Displays manipulated variable property view. Observable radio button Displays observable variable property view. Select All button With either the observable or manipulated variables in the table, this button selects all checkboxes in the active list. Click the Change Configuration button to see this button. Un-Select All button With either the observable or manipulated variables in the table, click this to unselect all checkboxes in the active list. Click the Change Configuration button to see this button. Remove Unselected button Removes all unselected variables from either the observable or manipulated tables. Click the Change Configuration button to see this button. Transitions Off/ On buttons The Transition On/Off buttons only appear when stream cutters are used, and you have selected the Advanced option mode. Stream cutters are inserted into the boundary streams when a subset of the flowsheets objects is selected. Object Description 10%± Refer to Section 5.11 - Stream Cutter for more information.14-154 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-155 ww ThData Tab The Data tab allows you to configure and generate input and output data sets for the Parametric model based on HYSYS simulations. Training data sets are generated by using stepwise changes to the manipulated input variables to produce varying output results. The table below describes the objects on the Output File Options group and Data Set Options group. Figure 14.85 Object Description Output File Options group Create as new radio button Create as new allows you to name and create a new file to store your data. This is a binary file that is used internally by the PM Utility and cannot be read in as a CSV file. When sharing a case in the PM utility, and the data has been generated, make sure the binary data file is also transferred, otherwise the data will have to be re- generated. Used to reset manipulated variables to their original values after data generation.14-155 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-156 Parametric Utility ww ThThe Manipulated Variable Set matrix is shown below with its corresponding buttons. The table below describes the objects on the Manipulated Variable set matrix. Append to existing radio button Append to existing saves your data to an existing *.dat file. This is useful when you want to append new data to previously generated data. Output File Browse button Click to browse for a *.dat file. View File Info button Displays a property view showing the *.dat file info, such as maximum file size, total number of records, and so forth. Output File Head Name field The path for the output file is specified here. Output File Extension field Specify the type of file you want to save the output file as. Data Set Options group Build Random Dataset button Picks random manipulated variables between high and low bounds for each variable. Read from CSV File button Click to browse for a *.csv file that you can import. It contains manipulated set points from a comma delimited file instead of entering data manually. In this file a line that begins with a * is taken as a comment line. Figure 14.86 Object Description Size column Enter the number of manipulated variable data sets you want to run. When you change this number, the number of data set columns associated with the variable list changes. Generate Data button Initiates the simulation engine to generate training data for the parametric model based on the HYSYS model. Object Description14-156 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-157 ww ThWhen setting up your Parametric model for the first time, click the Create as new radio button. This allows you to name and create a new file to store your data. Data is then written to an external file based on the default name and location (path) listed. Later, if you want to add to the number of data sets used for training (thereby increasing the accuracy of your Parametric model), choose the Append to existing radio button. Data is then written to an external file based on the default name and location listed (as shown in the previous figure). The Output File Options group displays information related to the training data file to be generated by the Parametric Utility. The Number of the Size field defines the number of data sets that are generated using the HYSYS model. Increasing this number increases the likelihood that the Parametric model is a “good fit” for the flowsheet model, however, the data takes longer to generate. Choosing the Number of Data Sets The number and range of your data sets should span the intrinsic dimension of your variable set. For example, completely span the range of your variables once all constant or linear relationships have been removed. Failure to do this may cause the Neural Network to fit a constant or linear relationship between two variables when a more complex one exists. Export to CSV... button Once data has been generated, you can save manipulated and observable data to a *.csv file; you can choose between a number of formats. View tables... button Views the manipulated and observable variables in the HYSYS environment. This is only available when the Advanced Option Mode is selected. If you have changed the model’s configuration, you should not append to existing data sets. Object Description14-157 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-158 Parametric Utility ww ThWhen the data has been generated, and the Init/reset button on the Training tab is pressed, the PM Utility displays a list of the MLP units, the number of inputs, the number of outputs, and the number of hidden units. A very rough rule of thumb, used by some researchers, is to count the number of weights in the network and multiply by 10. If you have an, n, input network with, k, hidden units and, m, outputs, then the number of weights (internal parameters adjusted during training) is: So if n = 13, m = 12, and k = 13, there will be 350 weights in the network. In practice, one can often manage with the fewest amount of data sets, but you should not have more weights than training examples. This number of input, output, and hidden training variables in the NN is only available once the data has been generated, and the relationships between the selected input and output variables are assessed. As such an incremental approach to generating data is recommended. Assume that there is only one hidden layer (in other words, in the above k = 1) and generate n + 1 + 2m data sets (48 data sets for this example). Proceed to the Training tab and press the Init/Reset button. The number of Input, Output, and hidden units in each MLP are displayed. Calculate the number of weights. If the number of weights are less than the number of data sets that have been generated, then you may consider training the NN. If the number of weights is greater than the number of data sets generated, return to the Data tab and click the Append to Existing radio button. Enter in a completely new set of data (using the same data does not help), and click Generate Data button again. Repeat this process until enough data sets have been generated, and appended to the original data file. This is only a rough rule of thumb. There is no substitute for understanding the system being modelled and looking at the data to check the regions where there are rapid changes between input and output, and then providing more examples in those regions. n 1+( )k k 1+( )m+14-158 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-159 ww ThTraining Tab The Training tab allows you to generate a Parametric model based on the HYSYS training data. Data sets generated on the Data tab are used as training variables. The training algorithm determines the parameter values of the neural network model based on the input and output data sets. The end result is a Parametric model which approximates its HYSYS model counterpart. The set of Training buttons are described below: Figure 14.87 Button Description Init/Reset Use this button before running the training algorithm or when you need to reset the Parametric model. Confirm Allows you to confirm the current training configuration. Train Initiates the training algorithm to train the neural network based on the data sets generated by the HYSYS model.14-159 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-160 Parametric Utility ww ThThe Sub-group models group allows filtering of neural network data using three radio buttons as described below: The Display Mode group displays model data in the table based on the radio button selected. You can also change the number of hidden layers in the MLP, and the number of cycles (in other words, number of times the data is presented to the nodes). Changing these may affect the efficiency of your model and is only recommended for the advanced user. View Table... Allows the viewing of training data in table format. Compares the HYSYS training data with Parametric model data. View Graph... Allows the viewing of training data in graphical format. Compares the HYSYS training data with Parametric model data. Radio Button Description All Displays both Simple and MLP combined. Simple Displays constant and linear variables. Those relationships that are not modeled by the MLP. MLP Displays Multilayer Perceptrons. Those relationships that are modeled by neural networks. Radio Button Description All All information associated with the model (type of model, number of inputs/outputs, and all variables associated with neural net trainer). MLP Model Displays the model type and information regarding NN representation parameters. Simple Model Displays the model type, number of inputs and outputs. Trainer Information that describes the training parameters for a given model. Button Description14-160 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-161 ww ThThe matrix group and the buttons below are described in the following table: In Advanced Mode, the following buttons are available on the Training tab: When in Advanced Mode, you can modify the following parameters: Object Description Blocks radio button Allows you to can examine the structure if data is put into multiple blocks or NN. Models radio button Allows you to examine the structure if data is put into model types. Model types available are: Manipulated, Constant, Ignored IntStr, and Simple Linear. PMBlock Number field Displays the PM block number. Button Description Load NN Allows you to load the Neural Network (*.nn file) into another Parametric Utility (of the same configuration), same Parametric Utility, or used with the Neural Network Manager. Save NN Allows you to save a trained Neural Network to a specific *.nn file. Parameter Description #Iters Maximum number of passes the training algorithm will take. Relative Tolerance Ratio of the change in error between two iterations to the actual error. If the value is below the tolerance training will stop. Abs Tolerance If the training error is below this value, training will stop. Refer to Section 14.14.4 - Neural Network (NN) Manager for more information.14-161 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-162 Parametric Utility ww ThValidation Tab The Validation tab is the final phase in developing a Parametric model. On this tab, validation of the model is performed by generating validation points using both the Parametric model and the HYSYS model and comparing the results. The Validation options are described below: Figure 14.88 Button Description Validation Setup Allows you to configure validation setup options which include the Number of Validation Points and the Random Speed used in generating the validation points. PM runs Runs the Parametric model to generate validation data based on the Parametric model. HYSYS runs Runs the HYSYS model to generate validation data based on the HYSYS model. View Tables... Allows the viewing of validation data in table format. Compares the HYSYS validation data with Parametric model data. View Graph... Allows the viewing of validation data in graphical format. Compares the HYSYS validation data with Parametric model data.14-162 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-163 ww ThThe Display Mode group has two radio buttons: The Filter group filters objects based on four radio button selections: After you have a trained NN, you can embed it into the HYSYS flowsheet to replace the objects you selected earlier by the trained NN; use the Embedded into HYSYS Flowsheet checkbox on the Configuration tab. If your streams are over specified, HYSYS filters the stream information for you to avoid consistency errors. Radio Button Description All Displays all the variable information. Validation Displays the validation range and error. Radio Button Description All Shows all variables. Objects are filtered differently depending upon whether they are manipulated or observable. Objects Shows the variables.filtered by the flowsheet objects. Simple Linear Shows the variables which have a constant or linear relationship. MLP Models Shows the variables which are used in the MLP model.14-163 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-164 Parametric Utility ww Th14.14.4 Neural Network (NN) Manager You can access the Neural Network Manager by clicking the NN Manager button on the Configuration tab of the Parametric Utility property view. Figure 14.89 The NN Manager button only appears when you select the Advanced option mode checkbox in the Calculation Options group of the Parametric Utility Configuration tab.14-164 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-165 ww ThThe Neural Network Manager allows you to switch Neural Network (NN) Objects into appropriately configured Parametric Utilities, and to generate simple Neural Network’s from external data. The Config Choose tab allows you to switch between the two NN Manager modes: • PMUtilities Manager • NN Creation PMUtilities Manager Mode There are four tabs available for the PMUtilities Manager mode: • Set Up • PMUtil Config • NN Config • Embedding Control Figure 14.9014-165 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-166 Parametric Utility ww ThSet Up Tab The Set Up tab displays the list of available Parametric Utilities and Neural Network Objects associated with the Parametric Utilities. The Set Up tab consists of the following fields: The following buttons allow you to load, remove or associate a Neural Network object with the Parametric Utilities. Figure 14.91 Field Description Selected PM Utility Displays the Parametric Utility that you have selected from the list of available PM Utilities Selected NN Displays the Neural Network (NN) object you have selected from the list of available NN’s. NN in PMUtil Displays the Neural Network (NN) object that is loaded in the Parametric Utility. Button Description Load NN From File Loads a Neural Network object into the Neural Network Manager and associates it with the Parametric Utility that you selected from the list of available PM Utilities. 14-166 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-167 ww ThParametric Utilities which have been trained are automatically added to the list of available PM Utilities. Neural Network objects have to be created from a trained Neural Network; on the Training tab of a Parametric Utility property view, in advanced mode, you can save or load a NN (.nn file) using the Save NN or Load NN buttons. Neural Network objects must have the same configuration as the Parametric Utility object they are being loaded into. Stream and unit operation names can be different, but the list of Manipulated and Observable variables must have the same type of variable in the same order. PMUtil Config Tab On the PMUtil Config tab you can view a list of the Manipulated and Observable variables for the Parametric Utility you selected from the list of available PM Utilities on the Set Up tab. Remove NN From List Removes the selected Neural Network object from the list of available NN’s and the Neural Network Manager. Load NN into PMUtil Loads the selected Neural Network object from the list of available NN’s into the selected Parametric Utility from the list of available PM Utilities. Figure 14.92 Button Description14-167 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-168 Parametric Utility ww ThYou can also view the Manipulated and Observable variables high and low values for the Parametric Utility you selected from the list of available PM Utilities on the Set Up tab. NN Config Tab On the NN Config tab you can view a list of the Manipulated and Observable variables for the Neural Network object you selected from the list of available NN’s on the Set Up tab. You can also view the Manipulated and Observable variables high and low values for the Neural Network object you selected from the list of available NN’s on the Set Up tab. Figure 14.9314-168 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-169 ww ThEmbedding Control Tab The Embedding Control tab allows you to control the different embedding options. The Embedding Control tab consists of three groups: • PMUtil Embedding Controls are described in the table below: • NN Manager Parameters. You can select the Deferred Embed checkbox, if the Neural Network Manager needs to switch a Neural Network into a Parametric Utility, but there is an adjust or recycle in the scope of the Parametric Utility, then the switch will be done after the adjusts and recycle have converged. Figure 14.94 Controls Description Embed Embeds the Parametric Utility into the flowsheet. Switch NN’s Switches the Neural Network’s into the Parametric Utility automatically to the one that fits the manipulated variable values most appropriately. Intel Embed The PMUtil makes choices to maximize a successful embedding, if they need to be made. Init Query If the you need to be queried on an embed, you will only be queried once. Range Check If the manipulated variable values are outside the range than the Neural Network in the Parametric Utility was trained upon, then the Parametric Utility is unembedded.14-169 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-170 Parametric Utility ww Th• Variable Weights. The weights used to determine the NN which fits the manipulated variable values most appropriately. The higher the values of the weight, the greater effect that variable bound has on selecting the NN. A weight of 0 shows the variable bound will have no effect. NN Creation Mode There are two tabs available for the NN Creation mode: • NN Generation • NN Utilization NN Generation Tab There are three groups on the NN Generation tab: • CSV File Configuration. Allows you to specify the row or column format for the data file, browse for the data file, and load the data file into the Neural Network Manager by clicking the Load Data button. • Data View. Displays the data loaded from the CSV file. • NN Training. Allows you to modify training parameters (#Iterations, Abs Tolerance, Relative Tolerance, #Hidden Layers, Scaling), and displays the Error of the trained Neural Network. When you click the Train NN button, it starts the training algorithm. Figure 14.95 Refer to Data File Format Group section from Section 5.6.2 - Design Tab in the HYSYS User Guide, for more information on specifying the row or column format for a data file.14-170 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-171 ww ThNN Utilization Tab The NN Utilization tab allows you to save or load trained Neural Network’s (.mlp files), and utilizes the *.mlp files for displaying the Inputs and Outputs in the table. Figure 14.96 The Neural Network’s stored here are in a different format from those used in the PMUtil Manager mode as they do not contain variable type information. The two formats are currently not compatible.14-171 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-172 Pipe Sizing ww Th14.15 Pipe Sizing With the Pipe Sizing utility you can perform design calculations on any of the case streams. Results include pipe schedule, pipe diameter, Reynolds number, friction factor, and so forth. 14.15.1 Design Tab The Design tab contains the following pages: • Connections • Notes Figure 14.97 To add the Pipe Sizing utility, refer to the section on Adding a Utility.14-172 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-173 ww ThConnections Page On the Connections page, you can select the stream that represents the pipe you want to size, the calculation type and characteristics of the pipe. You can also remove or change the streams to be used by clicking the Select Stream button, and changing the selection in the Select Process Stream property view. General Procedure The following are the steps to pipe size a selected stream. 1. On the Design tab, click the Connections page. 2. Click the Select Stream button. The Select Process Stream property view appears. 3. Select a stream for the analysis from the Object list. 4. Click the OK button to return to the Pipe Sizing property view. 5. You must select a calculation type from the Calculation Type drop-down list. The options available are: • Max. Diameter. The input required includes the pipe schedule, and the pressure drop in the pipe. • Pressure Drop. The input required includes the pipe schedule, and the pipe diameter. Figure 14.9814-173 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-174 Pipe Sizing ww ThThe following fields are available for each stream chosen. Notes Page The Notes page provides a text editor, where you can record any comments or information regarding the utility, or to your simulation case in general. Figure 14.99 Object Description Calculation Type Allows you to choose between two calculation types: • Max. Diameter • Pressure Drop Schedule Allows you to select a pipe schedule. You have four choices: • None • Schedule 40 • Schedule 80 • Schedule 160 If you selected Pressure Drop as your calculation type, the pipe schedule is automatically set as None. Diameter If you selected Pressure Drop as your calculation type, then you have to enter a value for the pipe’s actual inner diameter. HYSYS then calculates the pressure drop. Pressure Drop If you selected Max. Diameter as your calculation type, then you have to enter a value for the pressure drop. HYSYS then calculates the pipe’s actual inner diameter. For more information, refer to Section 1.3.5 - Notes Page/Tab.14-174 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-175 ww Th14.15.2 Performance Tab You can examine the results of the pipe sizing utility on the Results page of the Performance tab. Figure 14.10014-175 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-176 Property Balance Utility ww Th14.16 Property Balance Utility The Property Balance Utility allows you to inspect material and energy balances across the entire flowsheet or across selected operations. The Property Balance utility property view contains a Name field, a Scope Object button, a Delete button, a Refresh Scope Objects button, a Close button, and two tabs: Material Balance and Energy Balance. When you open the Property Balance Utility, the values are automatically calculated. However, when you make topology changes to the flowsheet, this utility is not automatically updated. To update this page, use the Refresh Scope Objects button. Selecting Scope for Balance Calculations Click the Scope Object button to select what operations you want to perform your material or energy balance calculation over. The Target Objects property view appears. The Target Objects property view contains two groups and three Figure 14.101 To add the Property Balance utility, refer to the section on Adding a Utility.14-176 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-177 ww Thsub groups. The Objects Available group contains tools to help you select the objects you want to perform the balance calculation over. Generalized Procedure for Selecting Objects 1. Select the flowsheet containing the objects you want from the FlowSheets group. Use the Object Filter radio buttons to help narrow your search. 2. Select the objects you want from the object list in the Objects Available group. Use the SHIFT or CTRL keys to select more than one object from the list. 3. Click the button to move the selected objects from the Objects Available group to the Scope Objects group. You can remove objects from the Scope Objects group by selecting the objects you do not want from the list, and clicking the button. To perform a material or energy balance over the entire flowsheet, you have to select all the operations in the flowsheet. You can also perform a material or energy balance over the entire main flowsheet by selecting the FlowSheet Wide radio button in the Object Filter group, and adding the FlowSheet Wide variable from the FlowSheet Wide group. Figure 14.10214-177 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-178 Property Balance Utility ww Th4. Once you have added all the objects you want in the Scope Objects group, click the Accept List button. Click the Cancel Changes button to exit the Target Objects property view without making any changes. 5. After clicking the Accept List or Cancel Changes button, you return to the Property Balance utility property view. 6. If you selected one object for balance calculation, the field beside the Scope Objects button displays the name of the object. If you had selected more than one object, the field displays the words Multi Hook. This indicates that more than one object was selected. 14.16.1 Material Balance Tab The Material Balance Tab contains two radio buttons that control the property view in the tab: • Setup • Balance Results Setup Radio Button The utility generates a balance on any stream property or combination of stream properties you select. You can set up multiple balances and view results of each balance in turn. On the Setup property view, you define the stream properties of interest (the variables), and the relationships between them Figure 14.10314-178 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-179 ww Th(the formulas). Figure 14.10414-179 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-180 Property Balance Utility ww ThThe following table contains the description of the objects in the Setup property view. Objects Description Insert Variable Allows you to insert a variable to the balance calculation. The variable you selected appears in the Variable column. Remove Variable Allows you to remove a variable from the table, select the variable you want to remove and click this button Variable column Displays the name of the variable you added to the balance calculation. The name is based off the text entered in the Description field from the Variable Navigator property view. Alias column Displays the name designated to the variable by HYSYS. The designated name is used to represent the variable when entering a formula equation. Insert Formula Allows you to insert a space for a formula in the formula table. Remove Formula Allows you to remove a formula from the table, select the formula you want to delete and click this button. Formula column Allows you to enter a formula equation. Alias column The column displays the name designated to the created formula by HYSYS. The designated name is used to represent the formula when entering a formula equation. Description column Allows you to enter a description about the formula. Variable Type column You can select the variable unit type for the calculated result of the formula in this column. The variable types available are contained in the drop-down list. HYSYS automatically assigns variable unit types to simple formula. An example is a formula with a temperature variable being multiplied by 2, HYSYS assigns Temperature as the formula’s variable unit type.14-180 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-181 ww ThAdding a Variable To add a variable: 1. In the Property Balance Utility view, click Insert Variable or double-click the < > cell. The Variable Navigator property view appears. 2. Select the Variable and Variable Specifics from the lists. You cannot add the following variables from the Variable list: 3. Click OK to return to the Property Balance Utility view. Notice that the variable you added appears in the variable table. Changing a variable To change an existing variable: 1. In the Property Balance Utility view, double-click the variable cell you want to change. The Variable Navigator appears. 2. Select the new Variable and Variable Specifics from the lists. Variable Specifics might not be available for every Variable. 3. To change the description of the variable, type the new description in the Description field. 4. Click OK. Adding a Formula To add a formula: 1. Click the Insert Formula button, an empty row for the • Heat Flow • Molar Enthalpy • Mass Enthalpy • Molar Entropy • Mass Entropy • Phase Enthalpy • Phase Entropy • Phase Heat Flow14-181 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-182 Property Balance Utility ww Thformula appears in the formula table. You can also enter a new formula by entering the formula in the < > cell. The Insert Formula button can be used to insert a formula in between a list of formulas. 2. Enter a formula equation in the Formula cell. To manipulate any of the variables from the variable list, you have to use the names of the variables from the Alias column. To view the syntax available in HYSYS, add a spreadsheet to the PFD, open the spreadsheet property view, and click the Function Help button. 3. You can change the Description of the formula by entering a new description in the Description cell. HYSYS sets a default description of the word Formula and the number designated to the formula. You can also select a variable type for the formula results. HYSYS default selection for the variable type is Unitless. You can also enter a formula containing another formula. An example is the table containing both formulas, f0 = v0-1 and Figure 14.105 Figure 14.106 The formulae follow the same syntax as the spreadsheet.14-182 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-183 ww Thf1 = f0*10. So formula f1 contains another formula f0. Setting up a Property Balance Suppose you want to look at the sulfur balance across a group of objects, and you are using refinery assays. You can do the following: 1. Add a Mass Flow variable (v0). 2. Add a Sulfur Content variable (v1). This variable is located by selecting Calculator in the Variable list and Sulfur Content in the Variable Specifics list from the Variable Navigator property view. 3. Add a formula of v0*v1/100 to get the mass flow of sulfur. 4. View the results of this formula by selecting the Balance Results radio button, and selecting the formula from the Balance Type drop-down list. Figure 14.107 Figure 14.10814-183 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-184 Property Balance Utility ww ThBalance Results Radio Button You can view the results of the selected variables and formula by selecting the Balance Results radio button. The following table contains the description of each object on the tab when you select the Balance Results radio button. Figure 14.109 Object Description Balance Type You can select the type of balance you want to see from the drop-down list. The type of balance comes from the variables you added and formulas you created when the Setup radio button was selected. Inlet Material Stream column Displays all the inlet streams considered for the balance calculation. If you selected one operation, then the inlet streams for that particular operation is considered. If you selected all the operations in the flowsheet, only the Feed Block streams are considered. Outlet Material Stream column Displays all the outlet streams considered for the balance calculation. If you selected one operation, then the outlet streams for that particular operation is considered. If you selected all the operations in the flowsheet, only the Product Block streams are considered. Refer to Section 12.2.3 - Dynamics Tab for more information regarding Feed Block and Product Block streams.14-184 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-185 ww Th14.16.2 Energy Balance Tab The Energy Balance tab displays the energy balance results across the operations you selected in the Targets Object property view. Counted column You can indicate which stream you do not want in the balance calculation by clearing the checkbox of the associated stream in this column. The default setting for the checkbox is active. Values column Displays the value of the variable for the associated stream. The variable is the selected variable from the Balance Type drop-down list. Total of Inlet Stream Displays the sum of the values in the Value column for the inlet streams. Total of Outlet Stream Displays the sum of the values in the Value column for the outlet streams. Imbalance Displays the result of subtracting the total inlet stream value from the total outlet stream value. Relative Imbalance Displays the percentage result of dividing the imbalance value by the total inlet stream value and multiplying that value by 100. Figure 14.110 Object Description14-185 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-186 Property Balance Utility ww ThThe table below contains the description of the objects on the Energy Balance tab. Object Description Inlet Stream column Displays all the inlet streams considered for the balance calculation. If you selected one operation, then the inlet streams for that particular operation is considered. If you selected all the operations in the flowsheet, only the Feed Block streams are considered. Outlet Stream column Displays all the outlet streams considered for the balance calculation. If you selected one operation, then the outlet streams for that particular operation is considered. If you selected all the operations in the flowsheet, only the Product Block streams are considered. Counted column You can indicate which stream you do not want in the balance calculation by clearing the checkbox of the associated stream in this column. The default setting for the checkbox of all the stream is active. Values column Displays the heat flow value of the associated stream. Total of Inlet Stream Displays the sum of the values in the Value column for the inlet streams. Total of Outlet Stream Displays the sum of the values in the Value column for the outlet streams. Imbalance Displays the result of subtracting the total inlet stream value from the total outlet stream value. Relative Imbalance Displays the percentage result of dividing the imbalance value by the total inlet stream value and multiplying that value by 100. Refer to Section 12.2.3 - Dynamics Tab for more information regarding Feed Block and Product Block streams.14-186 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-187 ww Th14.17 Property Table The Property Table utility allows you to examine property trends over a range of conditions in both tabular and graphical formats. Using a stream of known composition, you can target two independent variables and their respective ranges of interest. The range of each independent variable is distinct, and can be set as either an incremental range or a selection of specific values. Next, you can relate which dependent variables are to be displayed at each combination of the independent variables. Figure 14.111 To add the Property Table utility, refer to the section on Adding a Utility.14-187 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-188 Property Table ww Th14.17.1 Design Tab The Design tab contains the following pages: • Connections • Dep. Prop • Notes Connections Page On the Connections page, you can select the stream, the two independent properties, the range of values, and increments you want the utility to display. Independent Variables The following are the general steps required to set the independent variables. 1. On the Design page, click the Connections page. 2. Click the Select Stream button, and the Select Process Stream property view appears. 3. Select a stream for the analysis from the Object list. 4. Click the OK button to return to the Connections page. Figure 14.11214-188 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-189 ww Th5. On the Connections page, identify one or two independent variables in the Variable 1 and Variable 2 (if desired) input cells. The options include: • Pressure • Temperature • Vapour Fraction • Enthalpy • Entropy 6. Next, you can select the Mode for the independent variable(s). There are two options: • Incremental. The input required includes the number of increments, and values for the upper and lower bounds. The dependent variable(s) are calculated at each increment within the range. • State. You can input an unlimited number of specific values for the independent variable in the State Values matrix. For the incremental variable(s), specify an upper bound, a lower bound, and the number of increments. One of the independent variables must be either Pressure or Temperature. If the first variable selected is not Temperature or Pressure, the drop-down list for the second variable can be limited to Temperature, Pressure and Not Set. Figure 14.11314-189 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-190 Property Table ww ThNext, you need to specify the dependent property as stated in the red status bar. Dep. Prop Page On the Dep. Prop page, you can select the dependent variable. Dependent Variables The following are the general steps required to set the dependent variables. 1. On the Design page, click the Dep. Prop page. 2. Click the Add button, and the Variable Navigator property view appears. 3. Select a stream for the analysis from the Object list. Figure 14.11414-190 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-191 ww Th4. Click the OK button to return to the Dep. Prop page. 5. Repeat steps #2 to #4 to add more dependent variables. 6. Click the Calculate button once you’ve added all your variables. Figure 14.115 You can change the dependent variable by selecting the variable from the list and clicking the Edit button. You can remove the dependent variable from the list by selecting the variable, and clicking the Delete button. Figure 14.11614-191 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-192 Property Table ww ThThe Calculate button is located at the bottom of the property view. The Calculate button is only available when: • HYSYS has not calculated the values for the Property Table. • You have selected a stream, independent variable and dependent variable. Notes Page The Notes page provides a text editor, where you can record any comments or information regarding the utility, or to your simulation case in general. 14.17.2 Performance Tab You can examine the results of the property table utility in the pages on the Performance tab. The Performance tab contains the following pages: • Table • Plots Table Page A table listing the results of the property table calculations can be viewed on the Table page. This page lists the independent variables, the dependent variables, and the phases present at the given conditions. The phase column indicates the phases, which have been detected at each pair of independent property values. The V indicates vapour, L indicates a light liquid (hydrocarbon rich) phase, and H indicates the presence of a heavy liquid (aqueous) phase. For more information, refer to Section 1.3.5 - Notes Page/Tab.14-192 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-193 ww ThPlots Page The Plots page allows you to display the results of the Property Table utility calculations in a graphical format. You can select which dependent variable you want to display on the y-variable by selecting it in the Y Variable group. Figure 14.117 Figure 14.11814-193 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-194 Property Table ww ThClick the View Plot button to display the plot. To make changes to the plot appearance, right-click in the plot area and select Graph Control command from the object inspect menu to access the Graph Control Property View. Figure 14.11914-194 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-195 ww Th14.17.3 Dynamics Tab The Dynamics tab allows you to control how often the utility gets calculated when running in Dynamic mode. The Control Period field is used to specify the frequency that the utility is calculated. A value of 10 indicates that the utility be recalculated every 10th pressure flow step. This can help speed up your dynamic simulation since utilities can require some time to calculate. The Use Default Periods checkbox allows you to set the control period of one utility to equal the control period of any other utilities that you have in the simulation. For example, if you have five utilities and require them all to have a control period of 5 and currently the value is 8, with this checkbox selected if you change the value in one utility all the other utilities change. Alternatively, if you want all the utilities to have different values you would clear this checkbox. The Enable in Dynamics checkbox is used to activate this feature for use in Dynamic mode. Figure 14.12014-195 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-196 Tray Sizing ww Th14.18 Tray Sizing With the Tray Sizing utility you can perform design mode or rating mode calculations on part or all of a converged column. Packing or tray information can be specified relating to specific tower internals such as tray dimensions or packing sizes, design flooding, and pressure drop specifications. Results include column diameter, pressure drop, flooding, tray dimensions, and so forth. In Design mode, HYSYS allows you to perform a design sizing Figure 14.121 The Tray Sizing utility is only available for columns with vapour-liquid flows. This utility cannot be used to size the Liquid-Liquid Extractor. The Tray Sizing utility must correspond to a single column flowsheet tray section. You can set the default parameters for the Tray Sizing utility from the Session Preferences property view (from the Tools menu, select Preferences). On the Tray Sizing tab, the defaults for auto section parameters, trayed section, and packed section setups can be set. To add the Tray Sizing utility, refer to the section on Adding a Utility.14-196 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-197 ww Thbased on the vapour and liquid traffic in the column. Available design specifications in Design mode include: • For trayed and packed type sections: - Type of column internal parameters - Maximum allowable pressure drop - Maximum allowable flooding • For trayed type sections: - Maximum allowable downcomer backup - Maximum allowable weir loading - Various other tray parameters In Rating mode, HYSYS allows you to perform rating calculations based on a specified column diameter and fixed tray configuration. If desired, some of the tray dimensions can be left unspecified and HYSYS automatically calculate design values for them. Available design specifications in Rating mode include: • For trayed sections: - Number of flow paths (NFPs) - Column diameter - Downcomer widths • For packed sections: - Section diameter - Tray for Properties If you modify the variables in the Main Flowsheet or Column subflowsheet, the tray sizing utility redesigns and rerates all of the sections based on the current configuration using the new stage by stage traffic, physical, and transport property information from the Column subflowsheet.14-197 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-198 Tray Sizing ww Th14.18.1 Design Tab The Design tab contains the following pages: • Setup. Manages the column sizing sections. • Specs. Calculation mode and common tower sizing parameters. • Tray Interval. Detailed internal specifications. • Notes. A text editor within the utility for you to enter notes. Setup Page On the Setup page, you can select which column you want the tray sizing utility to calculate. This page contains several fields and a group. HYSYS allows you to create multiple stage sections so that you can compare column configurations with different internal types. Figure 14.122 You can change the name of the utility on the Setup page, by entering a new name in the Name field.14-198 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-199 ww ThTherefore, a given span of tray section stages can be sized more than once within a single Tray Sizing utility. However, a give stage cannot be included in more than one active section. Selecting the Column Trays To select the column trays for sizing: 1. On the Design tab, click the Setup page. 2. Click the Select TS button. The Select Tray Section property view appears. 3. Select the column and trays from the Flowsheet list and Object list. 4. Click OK. You return to the Setup page. Next, the tray section for which the sizing is desired has to be specified before starting any calculations. HYSYS automatically groups the column trays into sections, or you can add and define your own sections for the column. You can make a section active by selecting the Active checkbox for the selected section. Figure 14.12314-199 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-200 Tray Sizing ww ThSetup Sections Group The Setup Sections group contains the options you need to generate tray sections. There is a table and four buttons in the group. The table contains options for you to use in manipulating the tray section and the calculation method. The four buttons at the bottom of the table allow you to manipulate the number of tray sections attached to the utility. The following table contains a description of each option in the Setup Sections table. The buttons on the Setup Sections group remain greyed-out until a column is attached to the utility. Row Description Section Name Displays the name HYSYS designates to each tray section generated. You can change the tray section name in this field. Start Displays the starting stage of the tray section. You can change the tray/stage using the drop-down list. End Displays the stage where the tray section ends. You can change the tray/stage using the drop-down list. Internals You can select one of the following tray types for each tray section: • Sieve • Valve • Packed • Bubble Cap14-200 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-201 ww ThPacked Sections For the Packed type sections, Robbins or Sherwood-Leva- Eckert (SLE) design correlations are used in the calculation for predicting pressure drop and liquid hold-up in the trays. On the Specs page, you can select Robbins or SLE for the Packing Correlation (Perry’s Chemical Engineer’s Handbook, 4, Seventh Edition, 1977). The rest of the section internal parameters can be specified on the Specs and Tray Internals pages of the Design tab. Trayed Sections For the Trayed types sections (sieve, valve, or bubble cap), some of the tray configuration parameters are common to all tray types, and some are unique for each individual tray type. The internal parameters can be specified on the Specs and Tray Internals pages of the Design tab. Each of the tray types uses a different calculation method: • Valve tray calculations are based on the Glitsch, Koch, and Nutter valve tray design manuals (Handbook of Chemical Engineering Calculations, by Nicholas P. Chopey, McGraw Hill). • Sieve tray calculations are based on the valve tray manuals for tray layout, and Mass-Transfer Operations by Treybal (McGraw-Hill) for pressure drop, weeping, and entrainment calculations. • Bubble tray calculations are based on the method described in Design of Equilibrium Stage Processes by Bufford D. Smith (Wiley & Sons). Mode The tray sizing utility has two calculation modes: • Design • Rating You can only change the calculation mode on the Specs page of the Design tab. On the Setup page, the mode is view-only. Row Description14-201 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-202 Tray Sizing ww ThActive When this checkbox is selected for the tray section, the values calculated in the tray sizing utility are applied to the column calculations in the simulation case. More than one section can be active in a tray sizing utility. However, the same stage cannot be included in more than one active section. Before updating the column flowsheet with the information from the tray sizing utility, you must change the default arrangement of the pressure profile information in the Column subflowsheet. 1. In the Column Runner property view, on the Parameters tab, click the Profiles page. 2. The top and bottom stage pressures must be specified instead of the condenser and reboiler pressures. The condenser and reboiler delta P specifications do not need to be changed. 3. Run the column and then return to the utility. 4. In the Tray Sizing Utility property view, on the Design tab, click the Setup page. 5. Activate those calculated column sections that you want to use in your simulation. 6. Proceed to the Performance tab, and click on the Results page. 7. Click the Export Pressures button, which export the pressure information to the column runner. If your column is in a recycle, there is no automatic update of the pressure profile, it must be done manually. Status Indicates the status of the tray sizing calculation. The status read either Complete or Incomplete on a section by section basis. Design Limit Indicates the design specification that was the last to be satisfied. The five design specifications are: • Minimum diameter • Pressure drop • Flooding • Weir loading (trayed types only) • Downcomer backup (trayed types only) The design specification that is listed in the Design Limit specification field is the critical design specification that is closest to being exceeded if the column is sized any smaller. For trayed types, HYSYS uses individual design limits for the required active area and the required downcomer area design calculations. Limiting Stage Indicates the stage in the sizing section on which the design hinges. It is the stage that is closest to exceeding the design specifications limits. For trayed towers, there are two limiting trays: the tray that is closest to exceeding the design specification while satisfying the section’s active area needs, and the tray that satisfies the downcomer area. Row Description14-202 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-203 ww ThThe option buttons below the table below are: • Add Section • Copy Section • Auto Section • Remove Section Procedures for using these buttons are described in the following sections. Adding Tray Sections When using the Add Section button, HYSYS adds a new tray section covering the entire span of the column as the default size. This can be changed to a shorter span, if desired, by changing the start and end stages. A preliminary design calculation is automatically performed using all HYSYS default sizing parameters. To manually add tray sections: 1. Select the column trays you want to size. 2. Click the Add Section button. You can add more than one section by clicking the Add Section button again. Depending on the type of column you have, HYSYS displays warning property views that recommend what type of tray you should use for the column. 3. A section appears in the Setup Sections group. Figure 14.12414-203 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-204 Tray Sizing ww Th4. The information displayed in the Setup Sections group are default values HYSYS provides. You can change the information to suit your scenario. Using Auto Section The Auto Section feature in HYSYS provides a good starting point for the tray section analysis. The feature creates tower sections of constant diameter based on the parameters you specified. The following steps shows you how to attach the main tray section to the utility and use the Auto Section functionality to divide the column into sections: 1. Select the column trays you want to size. 2. Click the Auto Section button. The Auto Section Information property view appears. 3. In the Internal Type group, select the type of tray the column contains using the radio buttons. 4. In the Area Tolerance and NFP Diameter Factor group, HYSYS provides default values for area tolerance and NFP diameter factor. You can also enter the value you want in the field provided. Figure 14.125 Refer to Section 14.18.4 - Auto Section for more information about the Auto Section feature.14-204 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-205 ww Th5. Click the Next button. The Auto Section Information property view closes, and the Tray Section Information property view appears. 6. You can specify more details about the tray type in the group below the radio buttons. The group’s name depends on which tray type your select. 7. In the Common Tray Properties group, you can specify the values for tray spacing, tray thickness, tray foaming factor, maximum tray dP, and maximum tray flooding. 8. In the DC/Weir Info group, you can specify the information for weir height, maximum weir loading, downcomer type, downcomer clearance, and maximum DC backup. 9. Click the Complete AutoSection button, when you are done editing the tray section information. HYSYS proceeds with the Auto Section calculations. Figure 14.12614-205 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-206 Tray Sizing ww Th10.The Tray Section Information property view automatically closes, and you return to the Setup page of the Tray Sizing utility property view. Copying a Tray Section To copy a section perform the following steps: 1. Select the section you want to copy from the Setup Sections group. 2. Click the Copy Section button. 3. A copy of the selected section appears in the table. Removing a Tray Section To remove a section perform the following steps: 1. Select the section you want to remove from the Setup Sections group. 2. Click the Remove Section button. 3. HYSYS removes the selected section from the Setup Sections group. Figure 14.12714-206 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-207 ww ThSpecifying % Liquid Draw and Tray Vapour Sizing At the bottom of the Setup page, there are two fields: • % Liquid Draw. The % Liquid Draw field allows you to specify the percentage of side liquid draws to be used in the tray sizing calculations. When you specify a liquid percent, HYSYS assumes that your specified draw percentage is sitting on the tray. - The default value of 0% means that no additional liquid is assumed to be on the tray. - If you enter 100%, flooding increases because you have an additional volume of liquid equal to the draw rate sitting on the tray. The percentage value can be equivalent for all trays with draws. You cannot specify different percentages for different draws on different trays. • Use Tray Vapour to Size. If you have vapour feed(s) attached to your column, HYSYS can size the particular tray (which is attached to the vapour feed) using the vapour feed flowing into the tray section or the vapour flow leaving the tray. The Use Tray Vapour to Size field contains a drop-down list of the methods available in HYSYS: - Always Yes. HYSYS uses the vapour flow leaving the tray section to size the tray for all calculations. The effect of the feed on the tray sizing is considered in the calculation. This method generates results that closely represent reality. If you have a vapour feed to your column, you can choose which tray the feed vapour is taken into account in the sizing/flooding calculations. For example, if you have a vapour feed to tray 22 and you select Always Yes, HYSYS takes the vapour feed and assumes that it is in equilibrium with the vapour underneath tray 22. The vapour feed plus the vapour from tray 23 are used in sizing tray 22. - Always No. HYSYS uses the vapour feed to the section to size the tray for all calculations. The effect of the feed is not considered for this method. For example, if you have a vapour feed to tray 22 and you select Always No, HYSYS assumes that the vapour feed is in equilibrium with the vapour leaving tray 22. The assumed vapour feed is used in the sizing calculations from Tray 21. - Ask Each Time. Prior to calculating the Tray Sizing utility, HYSYS asks you to specify whether to use feed to the tray or vapour flow from the tray as a basis. A 14-207 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-208 Tray Sizing ww Thmessage appears for each vapour feed to your column prior to the calculations, as shown the in the figure below: T Specs Page The Specs page allows you to specify the column internals for each section.The options are arranged in a tabular format. Figure 14.128 The selection of method in the Use Tray Vapour to Size drop- down list affects all trays, regardless of whether they have a vapour feed or even any feed at all. The difference in method is its selection of the vapour that comes from the tray below or the vapour that leaves the tray as a basis for sizing calculations. Figure 14.12914-208 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-209 ww ThThe following tables outline the available design and tray configuration parameters applicable to the Trayed or Packed type column for the sizing calculation: Design Parameters Tray Configuration Parameters Parameter Trayed Packed Design Correlation X Foaming Factor X X Flooding X X Pressure Drop X X Downcomer Backup X Weir Loading X Parameter Valve Sieve Bubble Number of Flow Paths X X X Tray Spacing X X X Tray Thickness X X X Weir Height X X X Downcomer Type X X X Downcomer Clearance X X X Design Manual X Hole Area X X Hole Diameter X Hole Spacing X Hole Pitch X Valve Density X Valve Thickness X Orifice Type X Bubble Cap Slot Height X14-209 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-210 Tray Sizing ww ThGeneral Parameters The Section Name, Start Tray, End Trays, Internals, and Mode from the table on the Specs page are the same parameters as in the Setup page. However, you are only able to change the calculation mode for the section on the Specs page. The Sieve Tray Flooding Method drop-down list enables you to select the model used to simulate flooding in a Sieve type tray. HYSYS provides the following models: • Minimum Csb • Original Csb • Fair’s Modified Csb The Section Property Mode drop-down list enables you to select the start tray for the Property Mode calculations. HYSYS provides two selections: • The First Tray in Section option applies to a column with multiple sections and each section has different Property Mode calculations. • The First Tray in Column option applies to a column with single or multiple sections and only one type of Property Mode calculation is applied to the whole column. The following sections describe in detail the parameters available in the Tray Sizing utility and the default values that HYSYS provides. Number of Flow Paths The Number of Flow Paths (NFP) value represents the number of independent flow paths per tray. Usually a smaller tower diameter can be obtained by using multi-pass trays. However, with more flow paths, there is a reduction in the number of valves or sieve holes that can be placed on the tray. This can result in an increase in the pressure drop, an increase in downcomer backup, and a loss in tray efficiency. In Design mode, the NFP value is calculated if you do not specify the value. In Rating mode, you must specify the NFP value.14-210 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-211 ww ThThe following are general guidelines relating the number of flow paths and the tower diameter: If the NFP is not specified, HYSYS starts at one pass and increases the number of passes until the minimum diameter for that NFP is reached. If a smaller NFP is required, a new value can be entered that overrides the calculated NFP. A new solution is calculated as soon as the new NFP is entered. The figure below summarizes the basic physical layouts of the flow paths available. Number of Passes Min. Diameter (ft) Pref. Diameter (ft) 2 5 6 3 8 9 4 10 12 5 13 15 Figure 14.13014-211 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-212 Tray Sizing ww ThSection Diameter The Section Diameter value is the diameter of the tray section based on the NFP calculated or specified. Tray for Properties The Tray for Properties variable enables you to select the tray upon which the property calculation for the column will be based. Tray Spacing The tray spacing is the vertical distance between trays. Some general guidelines for tray spacing follow: The default value is 24 inches. In Design mode, the Section Diameter is calculated. In Rating mode, you must specify the Section Diameter value. The Tray for Properties variable is only applicable for Packed type columns. The variable can only be manipulated in Rating mode. Expected Tower Diameter (ft) Suggested tray Spacing (in) --- 12 (minimum) Up to 4 18 - 20 4 - 10 24 10 - 12 30 12 -24 3614-212 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-213 ww ThValve and Tray Material Thickness Since material thickness is often described in terms of gauge, the following table is provided for quick conversions between gauge and thickness in inches: The default tray thickness is 0.125 inches. Foaming Factor Foaming refers to the expansion of liquid due to passage of vapour or gas. Foaming Factor is a measure of the foaming tendency of the system. In general, a lower foaming factor results in a lower overall tray efficiency and requirements for a larger column diameter. The default foaming factor value is 1. Foaming factors typically seen in some common systems include the following: Gauge Thickness (in) 20 0.037 18 0.050 16 0.060 14 0.074 12 0.104 10 0.134 General Foaming Classification Foaming Factor Non Foaming Systems 1.00 Low Foaming Tendencies 0.90 Moderate Foaming Tendencies 0.75 High Foaming Tendencies 0.6 Absorbers Foaming Factor Ambient Oil (T > 0°F) 0.85 Low Temp Oil (T < 0°F) 0.95 DGA/DEA/MEA Contactor 0.75 Glycol Contactor 0.65 Sulfinol Contactor 1.014-213 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-214 Tray Sizing ww ThMax Delta P (Maximum Pressure Drop) The maximum allowable pressure drop per tray can be entered as a height of liquid. If the variable value is not specified: • For trayed type section, a default maximum of 4 inches of liquid is used. • For packed type section, a default specification is 0.5 inches of water per foot of packing is used. In packed type section, the specified variable value is applied on a pressure drop per height of packing basis. Maximum Flooding Flooding is brought about by excessive vapour flow, causing liquid to be extrained in the vapour flowing up the column. HYSYS will size the column so that for the given vapour and liquid traffic, the tower flooding does not exceed the specified Max Flooding variable on any stage. Crude/Vacuum Tower Foaming Factor Crude or Vacuum Fractionation 1.00 Fractionators Foaming Factor Hydrocarbon 1.00 Low MW Alcohols 1.00 Rich Oil DeC1 or DeC2 (top) 0.85 Rich Oil DeC1 or DeC2 (Btm) 1.0 Refrigerated DeC1 or DeC2 (top) 0.80 Refrigerated DeC1 or DeC2 (btm) 1.00 General Hydrocarbon Distillation 1.00 MEA/DEA Still 0.85 Glycol/DGA Still 0.80 Sulfinol Still 1.00 H2S Stripper 0.90 Sour Water Stripper 0.50 - 0.70 O2 Stripper 1.0014-214 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-215 ww ThThe maximum recommended value is 85% for normal service and 77% for vacuum or low pressure drop applications. The recommended percentage values yield approximately 10% entrainment. For column diameters under 36 inches, a reduced flooding specification of 65-75% should be used. A lower value can be specified to allow for contingencies, such as increased capacity.. Packing Correlation Packing Correlation specification has two options. • The Robbins correlation is valid only at loading factors < 20000 (liquid loading < 9200 lb/hr.ft2). This correlation, which is the default selection, is noted to be better at predicting pressure drop and liquid holdup, particularly with newer packing materials. • The SLE (Sherwood-Leva-Eckert) correlation is valid for towers operating above the loading factors of 20000 (liquid loading > 9200 lb/hr.ft2). HETP The height factor HETP relates to packed towers. The value refers to the height of packing that is equivalent to a theoretical plate. For design purposes, the most accurate HETP factors are those published by packing manufacturers. If not specified, a maximum flooding factor of 82% is used for flat orifice trays and 77% for venturi orifice trays. The default values are provided for all packing parameters with the exception of the packing type and the packed column diameter.14-215 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-216 Tray Sizing ww ThPacking Type The Packing Type variable refers to the material used in the packing towers. A list of the available packing types is shown in the following table. Packing Type Material Packing Type Material Ballast Rings M,P Jaeger_VSP_SS M Ballast Plus Rings M Koch-Sulzer(BX) Structured S Ballast Saddles P Lessing Experimental M Berl Saddles C Levapacking P Cascade MiniRing M,P,C Maspak P Chempak M Montz A-2 Structured S Flexipac Mellapac S Neo-Kloss Structured S Flexirings M Norton Intalox Metal Tower Packing M Gempak S Nutter Rings M Glitsch Grid S Pall Rings M,P Goodloe S Protruded M Wire Coil Packing M Raschig Rings 1/32 in wall CSteel Hy-Pak Rings M Raschig Rings 1/16 in wall CSteel Hyperfil S Raschig Rings C, Carbon Intalox Saddles C Super Intalox Saddles P Jaeger MaxPack SS M Tellerettes P Jaeger Tripacks P Cross-Partition Rings C The materials used for the different packings (unless otherwise noted) are: Metal(M), Plastic(P), Ceramic(C), and Metal Structured(S).14-216 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-217 ww ThTray Internals Page If the sizing section is specified as having trayed internals (Sieve, Valve, or Bubble Cap), then the internals can be further specified on the Tray Internals page. There are certain column parameters that are common to all trayed columns. You can specify these parameters or leave them at their default values. Sieve Tray Parameters In addition to the general Trayed type parameters, the Sieve tray has the following parameters: • Sieve Hole Pitch. Hole pitch refers to the distance between the centers of two adjacent holes. HYSYS requires the hole pitch to be within 1.5 to 5 times the hole diameter. The default hole pitch is 0.5 inches for a 0.187 inch diameter hole. • Sieve Hole Diameter. The default value for the hole diameter is 0.187 inches. Valve Tray Parameters The valve tray is the default tray type for trayed columns in design mode. This section defines the design parameters specific to valve trays. Figure 14.13114-217 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-218 Tray Sizing ww Th• Valve Material Density. The following table lists typical materials used for valves and their associated densities. • Hole Area (% of Active Area). The hole area variable is the percentage of the active area that is occupied by the valve holes with respect to the total tray area. The default value is 15.3%, which corresponds to 12 valve holes (each having a diameter of 1 17/32 inches) per square foot. • Valve Orifice Type. The Valve Orifice is the shape of the hole that is punched in the plate for the valve. As shown in the figure, there are two types of orifices: - Venturi. Used for low pressure drop applications. - Straight. Used for normal service. • Design Manual for Flooding Calculations. Results are presented for flooding calculations from three industry standard design manuals: Glitsch, Koch, or Nutter. Any one of the three methods can be selected as the basis for comparison with the maximum allowable % of flood design specification. The default design manual is Glitsch. Valve Material Density (lb/ft3) Carbon Steel 480 Stainless Steel 510 Nickel 553 Monel 550 Titanium 283 Hastelloy 560 The Hole Area can also be specified for Bubble Cap trays. Figure 14.13214-218 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-219 ww ThBubble Cap Trays • Bubble Cap Slot Height. This value represents the height of the slots around the base of the bubble caps, through which the gas and liquid are allowed to flow. The default slot height is 1.0 inch. • Hole Area (% of Active Area). The hole area variable is the percentage of the active area that is occupied by the bubble cap holes with respect to the total tray area. The default hole area is 15.3%, which corresponds to 12 bubble caps (each having a diameter of 1 17/32 inches) per square foot. Common Tray Parameters • Side Weir Type. A weir on the tray ensures that the liquid (holdup) on the tray is at a suitable height. This parameter is used to specify the side weir type only. There are two types of weirs available: straight and relief. - A relief weir lengthens the side weir without increasing the downcomer area. The relief weir sweeps back, then across the tray, enclosing some active area, as shown in the figure. A relief weir is used for high liquid loads or where a low pressure drop is required. Figure 14.13314-219 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-220 Tray Sizing ww Th- A straight weir follows the edge of the downcomer and is used for normal service. HYSYS uses a straight weir as the default. However, if the weir loading is above the maximum, a relief weir can be included to alleviate the problem. • Weir Height. The weir height is the distance from the tray to the top of the weir. A weir height of 2 inches is used in most applications. However, a smaller height can be used for low pressure drop or vacuum services. A larger weir height is used to obtain longer residence times (for example, chemical reaction services). The default value for weir height is 2 inches. In general, you can use the following standard values: • Maximum Allowable Weir Loading. The weir loading is a measure of the liquid loading on the weirs. Values of 60 - 120 USGPM/ft are typical. Weir loading may be reduced by increasing the number of flow paths or installing a relief weir. A weir loading as high as 240 USGPM/ft can sometimes be tolerated. If the weir loading is not specified, a default value of 96 USGPM/ft is used. • Downcomer Type. In the column, liquid falls from a tray to the one below it through the downcomers. There are two types of downcomers available: - Vertical. Due to cost considerations, a vertical downcomer is used for normal service and is the default in HYSYS. - Sloped. A sloped downcomer has a narrower width at the bottom. This structure allows more active area and more valves per tray, and it also results in a lower pressure drop. • Downcomer Clearance. The downcomer clearance is the distance between the bottom of the downcomer and the tray. The area available for liquid flow under the downcomer is dependent upon this height. A minimum seal of 0.5 inches is normally recommended. For high liquid velocities and the resulting high pressure drop, this can be reduced. If the downcomer clearance is not specified, a height of 0.5 inches less than the weir height If HYSYS installs a relief weir but you want a straight weir, re-specify a straight weir and rerun the tray in rating mode. Tray Spacing (in) Weir Height (in) 12 1.5 12 - 24 2 >24 2.514-220 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-221 ww This used. If the weir height and downcomer clearance are not specified, HYSYS provides a default weir height of 2 inches and a downcomer clearance of 1.5 inches. • Maximum Allowable Downcomer Backup. The allowable downcomer backup is measured as the percentage of the tray spacing that the liquid level in the downcomer is allowed to reach. This variable value represents the average for all the downcomers on the tray. If not specified, the following default values are provided by HYSYS: - 40% for services with a vapour density greater than 3 lb/ft3 - 50% for normal densities with a vapour density between 1 lb/ft3 and 3 lb/ft3 - 60% for densities less than 1 lb/ft3 Common Parameters for Rating Mode The following tray parameters are applicable in Rating mode: • Side DC Top Width. The top width of the downcomer side value is required in Rating mode calculation of the section’s performance. • Side DC Bottom Width. The bottom width of the downcomer side value can be specified if the downcomer is sloped and you want a more realistic value in the Rating calculations. • Centre DC Top Width. The top width of the downcomer centre value is required in Rating mode calculation of the section’s performance. • Centre DC Bottom Width. The bottom width of the downcomer centre value can be specified if the downcomer is sloped and you want a more realistic value in the Rating calculations. • O.C. DC Top Width. The top width of the downcomer off-centre value is required in Rating mode calculation of the section’s performance. • O.C. DC Bottom Width. The bottom width of the downcomer off-centre value can be specified if the downcomer is sloped and you want a more realistic value in the Rating calculations. • O.S. DC Top Width. The top width of the downcomer off-side value is required in Rating mode calculation of the section’s performance. Refer to Column Rating for more information.14-221 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-222 Tray Sizing ww Th• O.S. DC Bottom Width. The bottom width of the downcomer off-side value can be specified if the downcomer is sloped and you want a more realistic value in the Rating calculations. Notes Page The Notes page provides a text editor, where you can record any comments or information regarding the utility, or to your simulation case in general. 14.18.2 Performance Tab The Performance tab contains the following pages: • Results. Overall comparative section results and detailed tray sizing information. • Trayed. Pressure Drop, Downcomer, and Flooding results across the column. • Table. Tray section physical property profiles in the tabular form. • Plots. Tray section physical property profiles in the graphical form. Downcomer widths that are not specified can be calculated at optimal design values for the given number of flow paths. When calculated widths are applied to a vertical downcomer, no slope is assumed. For more information, refer to Section 1.3.5 - Notes Page/Tab.14-222 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-223 ww ThResults Page The Results page displays the specified and calculated details of variables and outputs in the tray section. You can also modify the specified tray variable values in the Results page. Any changes will automatically be reflected in the appropriate pages of the Design tab. The Section Results group has two radio buttons: • Trayed. Selecting this radio button tells HYSYS to calculate the tray size for a tray column/tower. • Packed. Selecting this radio button tells HYSYS to calculate the tray size for a packed column/tower. Clicking the Export Pressure button signals HYSYS to take the calculated pressure profile and export it to the active tray section, thus causing the column to reconverge to the pressure profile predicted by the tray sizing utility. A section in the utility must be made active, before this option can be used. Figure 14.13414-223 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-224 Tray Sizing ww ThClick the View Warnings button to see any problems HYSYS detects in the tray section. The figure below shows two possible warning messages if the incorrect tray type is selected. Trayed Page On the Trayed page, HYSYS displays tray-by-tray information for the selected section. To display information on Pressure Drop, Downcomer, or Flooding, select the corresponding radio button. To view the tray information of a different section, use the drop down menu. Figure 14.135 Figure 14.13614-224 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-225 ww ThTable Page The Table page contains two radio buttons (Vapour (to Tray) and Liquid (from Tray)) and a table that displays the values of six of column variables for each tray. The column variables are: • Mass Flow • Gas/Liquid Flow • Molecular Weight • Temperature • Density • Viscosity Select the Vapour (to Tray) radio button to view the column variable information for the vapour fluid in each tray. Select the Liquid (from Tray) radio button to view the column variable information for the liquid fluid in each tray. Figure 14.13714-225 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-226 Tray Sizing ww ThPlot Page The Plot page displays the following column variable values in a plot format for each tray: • Delta P (pressure difference) • Mole Wt (molecular weight) • Density • Pressure • Flow (mass flow rate) • Temp (temperature) • Viscosity • Surf Ten (surface tension) The plot contains one set of data for the vapour phase and one set of data for the liquid phase in each tray. Select the column variable radio buttons in the Plot group to view the vapour and liquid data for each tray. Figure 14.13814-226 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-227 ww Th14.18.3 Dynamics Tab The Dynamics tab contains the Calculation page. The Calculation page contains only one option, Calculate Now. By default, the Tray Sizing utility does not perform any calculations in Dynamic mode. To see the calculated sizing results in Dynamic mode, click Calculate Now. 14.18.4 Auto Section The Auto Section function is an optional method in design mode. When using Auto Section, HYSYS automatically calculates the sections for a column. The calculated variables are then transferred onto the main utility Setup tab where you can edit, copy, or delete the auto-generated sections. The Auto Section option gives you an excellent starting point in the design of a tower by performing a summary sizing of the tray section and splitting the column into sections of constant diameter. Figure 14.13914-227 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-228 Tray Sizing ww ThWhen using the Auto Section option to generate sections, HYSYS allows you to specify the internal type and values for the criteria that are used to generate a new section. The two criteria that you can specify to establish tower sections are: • Area Tolerance The Area Tolerance defines the magnitude of change in the calculated area that causes the start of a new section. HYSYS first performs a design for stage i (using the current parameters for the chosen internals) and the number of flow path (NFP) for the current section (valve, sieve, and bubble trays only) to determine the required area. This area is compared to the minimum and maximum areas for the current section, which HYSYS retains. If the magnitude of difference for either comparison exceeds the Area Tolerance variable, a new section is started beginning at stage i. The previous section can be assigned the maximum diameter for that section. If the calculated area for stage i is outside the range defined by the minimum and maximum for the section but does not exceed the tolerance, the calculated area for stage i replaces the appropriate stored value. • NFP Diameter Factor When the comparison of areas is complete, HYSYS recalculates the required area of each stage using a different NFPs. This area is compared with the previously calculated area for each stage. If the magnitude of the change is greater than the NFP Diameter Factor variable, The Auto Section option is not available until a tray section has been selected on the Setup tab of the tray sizing utility.14-228 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-229 ww Tha new section is generated. The entire column is stepped off in the above manner according to the Area and NFP guidelines. The calculated sections of constant diameter, NFPs, active area, and downcomer area are defined for the tower. When this initial sizing is complete, HYSYS re-rates each tray based on a diameter calculated from the maximum downcomer and active area required for trays in that section. This value is available on the Results page of the Performance tab of the utility property view. The limiting factor(s) for each section appear on the Setup tab. When using the Auto Section option, you are required to specify the tray internal type, either Sieve, Valve, Bubble Cap or Packed. In addition, you have the option of specifying the parameters for the chosen configuration. If no parameters are specified, HYSYS uses values from its default set. Figure 14.14014-229 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-230 Tray Sizing ww ThColumn Rating Column sections can be rated using the Rating calculation mode on the Specs page. From the Mode drop-down list, select Rating, as shown in the figure below. If you modify the Main Flowsheet or Column subflowsheet, the tray sizing utility redesigns and rerates all of the sections based on the current configuration using the new stage by stage traffic, physical, and transport property information from the Column subflowsheet. Trayed Section Rating For trayed sections, the minimum required information for HYSYS to calculate the section performance includes the number of flow paths and the column diameter. If desired, you can specify the following downcomer widths on the Tray Internals page: • Side top and optional bottom • Centre top and optional bottom • Off-side top and optional bottom • Off-centre top and optional bottom The optional bottom width allows for the specification of sloped downcomers. Downcomer widths that are not specified can be calculated at optimal design values for the given number of flow paths. The remaining tray configuration parameters can be specified as discussed in the Specs Page section. Once rating parameters have been set, HYSYS completes the rating calculations. Figure 14.14114-230 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-231 ww ThPacked Section Rating For packed sections, the required information for HYSYS to calculate the section performance includes both the Section Diameter and the Tray for Properties on the Tray Internals page. The remaining tray configuration parameters can be specified as discussed in the Specs Page section. Once rating parameters have been set, HYSYS completes the rating calculations. If HYSYS is unable to complete the calculations, this will be indicated on the property view’s status bar. To view the warnings generated, click on the Results page of the Performance tab and click the View Warnings button. 14.19 User Properties The User Property utility allows you to view User Properties (that you have defined) based on the composition of a stream. You can only add User Properties in the Basis environment. Possible uses of the User Property include as a specification in a distillation column or as a target variable in an Adjust operation. Figure 14.142 Refer to Chapter 7 - User Properties of the HYSYS Simulation Basis guide for detailed information concerning User Properties.14-231 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-232 User Properties ww Th14.19.1 Design Tab The Design tab contains the following pages: • Connections • Notes Connections Page You can specify the stream you want to attach to the utility, and add the properties you want on the Connections page. You can also change the name of the utility on this page, if desired. Figure 14.143 To add the User Properties utility, refer to the section on Adding a Utility. Click the View Formulae button to view the selected Mixing Rule formula.14-232 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-233 ww ThAdding a Stream to User Properties 1. On the Design tab, click on the Connections page. 2. Click the Select Stream button. The Select Process Stream property view appears. 3. Select a stream from the Object list, and click the OK button. You return to the Connections page. You can disconnect a stream by clicking the Disconnect button in the Select Process Stream property view. Notes Page The Notes page provides a text editor, where you can record any comments or information regarding the utility, or to your simulation case in general. 14.19.2 Performance Tab The Performance tab contains the Property Values page. Figure 14.144 For more information, refer to Section 1.3.5 - Notes Page/Tab.14-233 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-234 User Properties ww ThProperty Values The Property Values page contains two tables. The top table contains a list of all the components in the stream. The bottom table contains the parameter values for the equations to use on the Connections page. You can only change the parameter values of the property in the Basis Environment. Figure 14.145 It is recommended that you leave the mixing rule equation parameters at their default values. Refer to Section 7.3.1 - Data Tab in the HYSYS Simulation Basis guide, for information about the parameter values available for you to manipulate.14-234 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-235 ww Th14.20 Vessel Sizing The Vessel Sizing utility allows you to size and cost installed separator, tank, and reactor unit operations. You can select a vertical or horizontal orientation for the separator. To obtain a more effective analysis for your vessel, changes can be made to the default parameters provided by HYSYS. 14.20.1 Design Tab The Design tab allows you to select the vessel that is to be sized, the dimensions of the vessel, the vessel material, and the cost of the vessel. The tab consists of the following pages: • Connections • Sizing • Construction • Costing • Notes Figure 14.146 For a comprehensive costing and sizing software package for your entire case, Economix is available. Contact your nearest AspenTech office or agent for details. To add the Vessel Sizing utility, refer to the section on Adding a Utility.14-235 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-236 Vessel Sizing ww ThConnections Page On the Connections page, you select the vessel you want to size and the vessel’s orientation. You can also change the name of the utility on this page. To select a vessel: 1. On the Design tab, click on the Connections page. 2. Click the Select Separator button. The Select Separator property view appears. 3. Select the vessel you want to size from the Object list, and click the OK button. Figure 14.147 Figure 14.148 Clicking the Set Defaults button returns all of the original data provided by HYSYS.14-236 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-237 ww Th4. You automatically return to the Connections page. Now select the orientation of the vessel using the Vertical or Horizontal radio button. Sizing Page The Sizing page allows you to set the specification variables that are used to size the vessel. To select the specification variable: 1. Select the specification variable from the Available Specification group. 2. Click the Add Spec button. The specification variable is moved into the Active Specification group. 3. HYSYS provides default values for the specification, but you can change the values. Enter the value you want for the specification variable in the cell provided. The following is the list of available specifications that are specific to the orientation of the separator: • Max. Vapour Velocity • Diameter • L/D Ratio • Vapour Space Height Figure 14.149 If the diameter value is not specified, HYSYS automatically changes this value when the vessel orientation is switched.14-237 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-238 Vessel Sizing ww Th• Demister Thickness • Liquid Residence Time • Liquid Surge Height • Total Length - Height • Nozzle to Demister • Demister to Top • LLSD (Low Level Shut Down) • Total Separator Height To remove the specification variable: 1. Select the specification variable you want to remove from the Active Specification group. 2. Click the Remove Spec button. The specification variable is moved back into the Available Specification group. Construction Page On the Construction page, you can specify any of the following information for the vessel: • Chemical Engineering Index • Material Type: Carbon Steel, SS 304, SS 316, Aluminium • Mass Density • FMC (material of fabrication factor) • Allowable Stress • Shell Thickness • Corrosion Allowance Figure 14.15014-238 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-239 ww ThCosting Page You can modify the factors used in the sizing and cost equations on the Costing page. These factors deal with the Base Cost, Shell Thickness, Accessories Cost, and Shell Mass. You can also view the results of the cost analysis on this page in the Costing Results group. The Base Cost, Ladders and Platform Cost, and Total Cost are listed in $US. Notes Page The Notes page provides a text editor, where you can record any comments or information regarding the utility, or to your simulation case in general. HYSYS recalculates after each change is made on the Construction page. Blue text is entered by the user, and red text is entered by HYSYS. You can modify the blue and red text. Figure 14.151 View the various equations by clicking the Cost Equation Help button. For more information, refer to Section 1.3.5 - Notes Page/Tab.14-239 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-240 Vessel Sizing ww Th14.20.2 Performance Tab The Performance tab contains the following pages: • Sizing Results • Vapour Space A summary of the sizing results and vapour space are provided on the each page respectively. Figure 14.15214-240 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete Utilities 14-241 ww Th14.21 References 1 Marsland, R.H., “A User Guide on Process Integration for the Efficient Use of Energy”, Insitution of Chemical Engineers, England, 1982. 2 Ng, H.J., Robinson, D.B., Ind Eng Chem Fund., 15, 293 (1976) 3 Ng, H.J., Robinson, D.B., "The Measurement and Prediction of Hydrate Formation in Liquid Hydrocarbon-Water Systems", Ind. Eng. Chem. Fund.,15, 293 (1976) 4 Ng, H.J., Robinson, D.B., AIChE J., 23, 477 (1977) 5 Ng, H.J., Robinson, D.B., Ind Eng Chem Fundam, 19, 33 (1980). 6 Ng, H.J., Robinson, D.B., "A Method for Predicting the Equilibrium Gas Phase Water Content in Gas-Hydrate Equilibrium", Ind. Eng. Chem. Fund.,19, 33 (1980) 7 Overa, Sverre O., & Stange, Ellen, & Salater, “Per, Determination of Temperatures and Flow Rates During Depressurization and Fire”, presented at the 72 Annual GPA Convention, March 15-17, 1993, San Antonio, Texas. 8 Parrish, W.R., Prausnitz, J.M., I.E.C. Proc Des Dev, 11, 26 (1972). 9 Roberts, T.A., Medonos, S., Shirvill, L.C., “Review of the Response of Pressurised Process Vessels and Equipment to Fire Attack”, Offshore Technology Report - OTO 2000 051, June 2000. 10Sloan, E.D., Khoury, F., Kobayashi, R., I.E.C. Fundam, 15, 318 (1976). 11Sloan,Jr.,E.D.,Clathate Hydrates of Natural Gases, Macel Dekker, Inc., New York, 1989. 12van der Waals, J.H., Platteuw, J.C., Advan Chem Phys, 2, 1 (1959).14-241 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete 14-242 References ww Th14-242 w.cadfamily.com EMail:cadserv21@hotmail.com e document is for study only,if tort to your rights,please inform us,we will delete www The I-1 Index A Absorber See Column Absorber Template (Column) 2-31 Actuator 6-173 Adiabatic Efficiency 9-37, 9-62 Adjust 5-4 individual 5-19 maximum iterations 5-14 multiple 5-19 solving methods 5-9 start 5-18 step size 5-13 tolerance 5-13 Air Cooler 4-3 duty 4-4 dynamic 4-4 dynamic specifications 4-5 holdup 4-16 pressure drop 4-5 steady state 4-3 theory 4-3 Annular Mist 6-60 Assay curves 2-100 Assay Curves (Column) 2-100 ATV Tuning 5-282 Auto Section. See Column Sizing Utility. B Baghouse Filter 11-3 parameters 11-5 sizing 11-6 Balance 5-20 general 5-26 heat 5-25 mass 5-24 mass and heat 5-26 mole 5-24 mole and heat 5-25 types 5-21 Beggs and Brill Correlation 6-57 Bnd See also ESTIM DRU iteration output Boiling Point Curve Utility 14-7 BOX Method (Optimizer Operation) 7-14 Broyden Method (Adjust) 5-9 C Central difference interval See also ESTIM DRU initial problem parameters Col Dynamic Estimates 2-73 Cold Properties Utility 14-17 Cold Property Specifications (Column) 2-121 COLD start See also ESTIM DRU initial problem parameters Column 2-4 3-phase detection 2-15 absorber 2-20 acceleration 2-69 advanced solving options 2-49 build environment 2-9–2-11 composition estimates 2-56–2-58 conflicting specifications 2-200 conventions 2-29 convergence 2-43 damping 2-70 design tab 2-38 dynamics tab 2-118 equilibrium error 2-62, 2-201 flowsheet tab 2-104 flowsheet variables 2-106 fluid package 2-6 heat and spec error 2-62–2-63, 2-197, 2- 200 impossible specifications 2-199 initial estimates 2-16 inner loop errors 2-194 input errors 2-198 installation 2-25 k value 2-13 operations 2-136 packed section rating 14-231 parameters tab 2-54 partial condenser 2-24 performance tab 2-91 plots 2-94 poor initial estimates 2-197 property view 2-8 rating tab 2-87 reactions tab 2-110 reboiled absorber 2-22 refluxed absorber 2-21.c doadfamily.com EMail:cadserv21@hotmail.com cument is for study only,if tort to your rights,please inform us,we will delete I-2 www The I-2 run / reset buttons 2-38 runner 2-37 running 2-193–2-195 See also Tray Section side ops tab 2-82 solver 2-5 solver tolerance 2-51 specification types 2-121 specifications 2-121–2-134 stream specification 2-135 tee 2-191 theory 2-11 transfer basis 2-37, 2-105 trayed section rating 14-230 troubleshooting 2-196 worksheet tab 2-90 Column Runner 2-37–2-119 Column Sizing Utility auto section 14-227 design 14-198 material thickness 14-220 NFP factor 14-228 packed section input 14-215 packed sections 14-201 tray spacing 14-212 Trayed Sections 14-201 trayed sections 14-201 Column Subflowsheet 2-4 relationship with main flowsheet 2-9–2- 11 Component Flow Rate Specification (Column) 2-122 Fractions Specification (Column) 2-122 Ratio Specification (Column) 2-123 Recovery Specification (Column) 2-123 Component Curves Utility 14-23 results 14-26 Component Map 13-10 Component Splitter 10-2 splits page 10-6 theory 10-2 Compressor, Centrifugal 9-2 curves 9-17 isentropic efficiency 9-4 solution methods 9-3 theory 9-4 Compressor, Reciprocating 9-48 maximum pressure 9-53 piston displacement 9-50 rod loading 9-53 theory 9-49 Compressor/Expander capacity 9-41 duty 9-39 efficiency 9-39 features 9-3 head 9-41 holdup 9-47 speed 9-42 surge control 9-43 Cond H See also ESTIM DRU iteration output Cond Hz See also ESTIM DRU iteration output Cond T See also ESTIM DRU iteration output Condenser fully-condensed 2-24 fully-refluxed 2-24 partial 2-24 See Vessels Condenser (Column) 2-138 duty 2-142 pressure drop 2-141 subcooling 2-142 Conduction through insulation/pipe 6-84 Control Valve 5-175 See Valve 5-175 Controller See PID Controller or Digital Point Conv See also ESTIM DRU iteration output Cooler 4-45 duty 4-50 pressure drop 4-49 theory 4-45 zones 4-53 Cooler/Heater dynamic specifications 4-58 holdup 4-61 pressure drop 4-46 zones 4-57, 4-59 Crash tolerance See also ESTIM DRU.c doadfamily.com EMail:cadserv21@hotmail.com cument is for study only,if tort to your rights,please inform us,we will delete www The I-3 I-3 initial problem parameters Create Column Stream Spec Button 12-12 Critical Properties Utility analysis 14-32 quick start 14-29 true and pseudo 14-29 CSTR 8-5 reactions 8-17 Cut Point Specification 2-124 Cyclone 11-8 constraints 11-14 parameters 11-10 sizing 11-13 solids information 11-11 D Damping Factors recycle 5-209 Darcy friction factor 6-170 Data Recon Utility property view DCS Tags tab 14-46 Parameter Fit tab 14-45 Results tab 14-42 Stream Initialization tab 14-44 Data Set Configuration See also Data Recon Utility Configuration tab Delta Temp Specification column 2-125 heat exchanger 4-107 LNG exchanger 4-177 Depressuring Utility types 14-63 Derivative level See also ESTIM DRU initial problem parameters Difference interval See also ESTIM DRU initial problem parameters Digital Point connections 5-181 parameters 5-182 Direct Action 5-110 direct energy stream 1-16 Distillation Column See Column Distillation Column Template 2-33 Dittus and Boelter Correlation 6-82 Draw Rate Specification (Column) 2-124 Duty Ratio Specification (Column) 2-126 Duty Specification column 2-125 heat exchanger 4-107 Dynamic Depressuring 14-60 connections 14-65 detailed heat loss 14-74 heat flux 14-69 operating conditions 14-82 operation modes 14-63 performance 14-85 pv work term contribution 14-81 simple heat loss 14-73 strip charts 14-67, 14-86 subflowsheet 14-61 valve equations 14-77 valve parameters 14-77 Dynamic Estimates Integrator 2-73 dynamics mode license 1-4 E Energy Stream 12-2 convert to material stream 12-3 Envelope Utility 14-87 connections 14-88 PF-PH-PS 14-91 plots 14-89, 14-144 pressure-temperature 14-90 TV-TH-TS 14-91 EPS (machine precision) See also ESTIM DRU initial problem parameters Equilibrium Reactor 8-22 Ergun Equation 8-81 ESTIM DRU diagnostic file output final output 14-58 initial problem parameters 14-53 iteration output 14-56 error detection/correction 14-35 gross error detection 14-37 model updating 14-35 utilities 14-35 utilizing 14-35 Examples pipe segment 6-106 Expander 9-2.c doadfamily.com EMail:cadserv21@hotmail.com cument is for study only,if tort to your rights,please inform us,we will delete www The I-4 I-4 curves 9-17 isentropic efficiency 9-4 solution methods 9-3 theory 9-4 F Face Plate 5-285 Face Plates object inspection 5-287 Feed Ratio Specification (Column) 2-126 Feeder Block 12-34 Filters baghouse 11-3 rotary vacuum 11-22 Fired Heater (Furnace) combustion reaction 4-64 conductive heat transfer 4-69 convective heat transfer 4-68 duty 4-83 dynamic specifications 4-70 features 4-63 flue gas 4-86 flue gas pf 4-88 heat transfer 4-65, 4-79 holdup 4-89 nozzles 4-79 process fluid 4-85 radiant heat transfer 4-67 sizing 4-75 theory 4-64 tube side pf 4-87 Fittings Database modifying 6-106 Fletcher Reeves Method (Optimizer Operation) 7-16 Flow Control Valve (FCV) 5-175 Flowsheet tags 13-6 Flowsheet Menu notes manager 1-28 Function precision See also ESTIM DRU initial problem parameters G Gap Cut Point Specification 2-127 General Balance 5-26 ratios 5-26 Gibbs Reactor 8-28 Gregory Aziz Mandhane Correlation 6-60 H Heat Balance 5-25 Heat Exchanger 4-89 basic model (dynamic rating) 4-102, 4- 114 delta pressure 4-118 detailed model (dynamic rating) 4-102, 4- 116 dynamic rating 4-102 dynamic specifications 4-93 end point design model 4-97, 4-101–4- 102 heat balance 4-105 heat loss 4-124 holdup 4-136 models 4-97 plots 4-128 pressure drop 4-92 See also Vessels steady state rating model 4-101 theory 4-90 weighted design model 4-99, 4-102 Heat Exchangers zones 4-116 Heat Loss Model detailed 10-30 heat exchanger 4-124 simple 4-51, 10-28 Heat Transfer coefficients 4-117 conductive elements 4-121 convective elements 4-121 duty parameters 1-16 kettle chiller 1-20 kettle heat exchanger 1-20 kettle reboiler 1-20 PFR 8-82 reactors 8-41 separator 10-15, 10-50 tank 10-15, 10-50 three-phase separator 10-15, 10-50 Heater 4-45 duty 4-50 pressure drop 4-49 theory 4-45 zones 4-53 Heavy Key (Shortcut Column) 10-53.c doadfamily.com EMail:cadserv21@hotmail.com cument is for study only,if tort to your rights,please inform us,we will delete www The I-5 I-5 Hydrate Calculation Models 14-126 assume free water 14-131 asymmetric 14-132 symmetric 14-132 vapour only 14-132 Hydrate Formation Utility 14-126 calculation models 14-126 formation pressure 14-138 formation temperature 14-137 hydrate inhibition 14-138 ice formation 14-133 stream conditions 14-135 Hydrocyclone 11-16 constraints 11-21 parameters 11-18 sizing 11-20 solids information 11-19 Hysteresis 6-122 HYSYS Dynamics License 1-4 I If/Then/Else Statements 5-235 Infinite bound size See also ESTIM DRU initial problem parameters Infinite step size See also ESTIM DRU initial problem parameters Inform See also ESTIM DRU final output Input Experts 2-27 Inside Film Convection 6-81 Isentropic Power 9-7 Iteration Count recycle 5-206, 5-209 Itn See also ESTIM DRU iteration output ItQP See also ESTIM DRU iteration output J JJ initial Hessian See also ESTIM DRU initial problem parameters K k Values See also specific Unit Operations L Lag Function second order 5-277 Lagr Mult See also ESTIM DRU final output Lapple Efficiency Method (Cyclone) 11-11 Leith/Licht Efficiency Method (Cyclone) 11-11 Light Key (Shortcut Column) 10-53 Lin See also ESTIM DRU iteration output Linear constraints See also ESTIM DRU initial problem parameters Linear feasibility See also ESTIM DRU initial problem parameters Liner parameters 6-28 Linesearch tolerance See also ESTIM DRU initial problem parameters Liquid Flow Specification (Column) 2-128 Liquid Heater 1-17 Liquid-liquid Hydrocyclone add 6-23 attach streams 6-24 characteristic diameter 6-18 configure Liner type 6-28 configure parameters 6-25 Connections page 6-24 create 6-23 cummulative distribution 6-17 delete 6-24 dense dispersion 6-21 Design tab 6-24 dimensions schematic 6-18 Droplet Distribution page 6-29 Dynamics tab 6-34 General page 6-30 general results 6-30 Geometric page 6-31 geometric results 6-31 graphical representation 6-22.c doadfamily.com EMail:cadserv21@hotmail.com cument is for study only,if tort to your rights,please inform us,we will delete www The I-6 I-6 hydraulics 6-19 Hydrocyclone Number 6-19 ignore 6-24 inlet diameter 6-18 Liner Details page 6-28 Liner dimensions 6-18 Migration Probability 6-21 Migration Probability results 6-33 MP 6-21 nomenclature 6-34 Notes page 6-30 oil droplet distribution 6-17 Oil Droplet Distribution results 6-33 overflow diameter 6-18 Overflow page 6-31 overflow results 6-31 Parameters page 6-25 Performance tab 6-30 Plots page 6-33 property view 6-23 Reduced Migration Probability 6-21 Reynolds Number 6-19 RMP 6-21 Rosin Rammler distribution 6-29 Rosin Rammler modal diameter 6-17 Rossin Rammler 6-17 separation efficiency 6-22 Serck Baker OilSpin 6-28 split ratio 6-20 Tabular page 6-33 Taper angles 6-18 theory 6-16 underflow diameter 6-18 Underflow page 6-32 underflow results 6-32 User Variables page 6-30 Vortoil G-liners 6-28 Worsheet tab 6-34 LMTD air cooler 4-4, 4-13 heat exchanger 4-91 LNG exchanger 4-178, 4-187 LNG counter current flow 4-195 cross flow 4-195 dynamic specifications 4-196 features 4-163 heat transfer 4-182 holdup 4-198 k values 4-197 laminar flow 4-197 layers 4-180–4-181, 4-191 parallel flow 4-195 pressure drop 4-165, 4-196 zones 4-180 LNG Exchanger 4-163 heat balance 4-175 plots 4-189 Logical Operations See Digital Point, PID Controller, Selector Block, Set, Spreadsheet and Transfer Function Lower Bound See also ESTIM DRU final output M Main Flowsheet relationship with column subflowsheet 2-4 Majits See also ESTIM DRU final output Major iterations limit See also ESTIM DRU initial problem parameters Major print level See also ESTIM DRU initial problem parameters Manipulated Variables 5-197 Mapping 13-10 Mass Balance 5-24 Material Stream 12-5 Minor iterations limit See also ESTIM DRU initial problem parameters Minor print level See also ESTIM DRU initial problem parameters Mixed Method (Optimizer Operation) 7-15 Mixer 6-35 holdup 6-42 nozzles 6-40 Mole and Heat Balance 5-25 Mole Balance 5-24 MPC Controller output target object 5-138.c doadfamily.com EMail:cadserv21@hotmail.com cument is for study only,if tort to your rights,please inform us,we will delete www The I-7 I-7 N Net Positive Suction Head (NPSH) 9-82 Neural Networks See Parametric Unit Operation Neural Networks See Parametric Utility. NFP Factor See Column Sizing Utility. Ngrad See also ESTIM DRU final output Nonlinear constraints See also ESTIM DRU initial problem parameters Nonlinear feasibility See also ESTIM DRU initial problem parameters Nonlinear Jacobian vars See also ESTIM DRU initial problem parameters Nonlinear objective vars See also ESTIM DRU initial problem parameters Norm Gz See also ESTIM DRU iteration output Normalizing Compositions 12-25 NormGf See also ESTIM DRU iteration output Notes Manager 1-28 Nz See also ESTIM DRU iteration output O object inspect menu 1-11 Objective See also ESTIM DRU iteration output Observarable Variables 5-198 OLGAS Correlation 6-62 Operation(s) installing 1-6 property view 1-9 Optimality tolerance See also ESTIM DRU initial problem parameters Optimization Objects 14-48 property view Connection tab 14-49 Properties tab 14-49 Transfer tab 14-52 Optimizer 7-2 BOX method 7-14 configuration tab 7-4 constrant function 7-8 example 7-35 fletcher reeves method 7-16 function setup 7-12 hyprotech sqp 7-18 mdc optim 7-4 mixed method 7-15 optimizing overall UA 7-40 original 7-5 property view 7-3 quasi-newton method 7-16 schemes 7-12 SQP method 7-15 tips 7-17 types 7-4 Outside Conduction/Convection 6-83 P Packed Towers See Column Sizing Utility. Parameter/Offsets See also Data Recon Utility Results tab Parametric 14-145 Parametric Unit Operation 5-190 connections 5-191 inputs from data file 5-193 manipulated variables 5-197 observable variables 5-198 setup 5-195 training 5-198 training pairs 5-197 utility data 5-192 Parametric Utility 14-145 Paste Exported Objects 13-5 Percent Heat Applied 1-17 Petukov Correlation 6-81 PFR. See Plug Flow Reactor Physical Property Specification (Column) 2- 128 PID Controller ATV tuning 5-282.c doadfamily.com EMail:cadserv21@hotmail.com cument is for study only,if tort to your rights,please inform us,we will delete www The I-8 I-8 configuration 5-107, 5-141 connections 5-102 control valve 5-175 controller action 5-110 Faceplate 5-180 flow control valve 5-175 modes 5-108 output target object 5-105 process variable source 5-103, 5-138 set point ramping 5-112 tuning 5-109 Pipe Contribution 6-169 Pipe Material Type 6-71 Pipe Segment 6-43 adding 6-68 calculation modes 6-44 example 6-106 flow calculation 6-48 heat transfer 6-77 length calculation 6-47 material and energy balances 6-49 pressure drop calculation 6-45 removing 6-77 roughness factor 6-70 sizing 6-67 Pipe Sizing Utility 14-172 Pipe. See Pipe Segment Plug Flow Reactor 8-74 catalyst data 8-91 duty 8-82 heat transfer 8-82 physical parameters 8-100 pressure drop 8-80 reaction balance 8-96 reaction extents 8-95 reactions 8-87 sizing 8-97 Plug Flow Reactors (PFR) duty 8-106 k values 8-104 segment holdup 8-105 Polytropic Efficiency 9-19, 9-37, 9-62 Polytropic Power 9-7 Power Requirement pump 9-64 Pressure Flow pipe contribution 6-169 Pressure Profile LNG exchanger 4-173 Product Block 12-34 Property Table Utility 14-187 dependent variables 14-190 independent variables 14-188 plots 14-193 tables 14-192 Pump 9-63 capacity 9-94 curve data 9-77 curve profiles 9-79 curves 9-69 dynamic specifications 9-91 efficiency 9-93 features 9-63 generate curve options 9-80 head 9-92 holdup 9-95 inertia 9-84 linked 9-73 nozzles 9-84 NPSH 9-82 power 9-94 pressure rise 9-93 pump efficiency 9-64 pump switch 9-66 speed 9-93 theory 9-64 Pump Around 2-85 column specifications 2-128 Q Quasi-Newton Method (Optimizer Operation) 7-16 R Reactor 8-3 CSTR 8-5 equilibrium 8-22 general 8-5 gibbs 8-28 parameters 8-7 PFR 8-74 Reactors duty parameters 8-41 heat transfer 8-41 holdup 8-40 nozzles 8-35 See also Vessels Reboiled Absorber.c doadfamily.com EMail:cadserv21@hotmail.com cument is for study only,if tort to your rights,please inform us,we will delete www The I-9 I-9 See Column Reboiled Absorber Template (Column) 2-32 Reboiler 2-25 See Vessels Reboiler (Column) 2-157 duty 2-159 pressure drop 2-159 Reciprocating Compressor features 9-49 Recycle 5-199 calculations 5-213 damping factors 5-209 maximum iterations 5-208 types 5-207 Reflux Ratio Specification (Column) 2-131 Refluxed Absorber See Column Refluxed Absorber Template (Column) 2-32 Relief Valve 6-111 capacity correction 6-116 flow equations 6-116 holdup 6-122 nozzles 6-119 types 6-115 valve lift 6-121 Reset frequency See also ESTIM DRU initial problem parameters Residual See also ESTIM DRU final output Resistance Equation rotary vacuum filter 11-28 Reverse Action 5-110 Rosin Rammler distribution 6-29 Rotary Vacuum Filter 11-22 cake properties 11-27 parameters 11-25 resistance equation 11-28 sizing 11-26 Roughness Factor (Pipe) 6-70 S Secant Method (Adjust) 5-9 Selector Block 5-219 connections 5-220 Separator 10-12 duty parameters 2-153, 2-168, 10-50 heat exchanger 10-50 kettle heat exchanger 2-153, 2-168 physical parameters 10-15 reaction sets 10-21 See Vessels theory 10-14 Sequential Quadratic Programming (Optimizer Operation) 7-15 Serck Baker Oilspin liners 6-16 Set 5-226 Set Point Ramping 5-112 Shells baffles 4-113 diameter 4-112 fouling 4-112 in parallel 4-110 in series 4-110 shell and tube bundle data 4-112 Shortcut Column 10-51 Side Operations Input Expert 2-82 Side Rectifier 2-84 Side Stripper 2-82 Sieder and Tate Correlation 6-82 Simple Filter. See Simple Solid Separator Simple Solid Separator 11-29 splits page 11-32 Solid Operations baghouse filter 11-3 cyclone 11-8 hydrocyclone 11-16 rotray vacuum filter 11-22 simple solid separator 11-29 Solver Parameters and Tolerances See also Data Recon Utility Configuration tab Specifications active 2-44, 4-106 advanced solving options 2-49 alternate 2-45 completely inactive 4-106 current 2-45 estimate 2-44, 4-106 fixed and ranged 2-50 heat exchanger ??–4-744-105–4-107 LNG Exchanger 4-175 primary and alternate 2-50 property view 2-48 types 2-121 Splits component splitter 10-6.c doadfamily.com EMail:cadserv21@hotmail.com cument is for study only,if tort to your rights,please inform us,we will delete www The I-10 I-10 Simple Solid Separator 11-32 Spreadsheet 5-229 exporting variables 5-230, 5-236, 5-239 general math functions 5-232 importing variables 5-230, 5-236, 5-239 logarithmic functions 5-233 logical operations 5-235 trigonometric functions 5-234 SQP Method. See Sequential Quadratic Programming State See also ESTIM DRU final output Steady State Mode terminology 1-4 Step See also ESTIM DRU iteration output Step limit See also ESTIM DRU initial problem parameters Stopping/Resetting Column Calculations 2- 195 Stream Column Specifications 2-135 Streams energy (See Energy Stream) material (See Material Stream) Strip Chart 1-30 Subflowsheet 13-3 blank flowsheets 13-5 connections 13-6 feed and product connections 13-7 installing 13-4 mapping 13-10 parameters 13-8 transfer basis 13-9 variables 13-14 Subflowsheets parameters 13-8 Surge Control 9-43 T Tank 10-12 duty parameters 2-153, 2-168, 10-50 kettle heat exchanger 2-153, 2-168 physical parameters 10-15 reaction sets 10-21 See Vessels TBP Envelope 2-103 Tear Location (Recycle) 5-214 Tee 6-124 holdup 6-131 splits 6-126 Tee (Column) 2-191 Tee Split Fraction Specification (Column) 2- 132 Templates 3 sidestripper crude column 2-26 4 sidestripper crude column 2-26 absorber 2-31 column 2-28–2-37 distillation 2-33 FCCU main fractionator 2-26 liquid-liquid extractor 2-25 reading existing 13-5 reboiled absorber 2-32 refluxed absorber 2-32 vacuum reside tower 2-26 Three Phase Distillation detection of three phases 2-15 three phase theory 2-15 Three Phase Separator duty parameters 2-153, 2-168, 10-50 heat exchanger 10-50 kettle heat exchanger 2-153, 2-168 Three-Phase Separator 10-12 physical parameters 10-15 reaction sets 10-21 See Vessels theory 10-14 Training 5-198 Training Pairs 5-197 Transfer Function 5-265 integrator 5-271 lag function 5-273 lead function 5-274 sine wave function 5-278 Transport Property Specifications (Column) 2- 133 Tray Section efficiencies 2-185 heat loss 2-182 holdup 2-190 nozzles 2-182 Tray Section (Column) 2-173 connections page 2-174 parameters page 2-175.c doadfamily.com EMail:cadserv21@hotmail.com cument is for study only,if tort to your rights,please inform us,we will delete www The I-11 I-11 performance page 2-186 pressures page 2-178 side draws page 2-175 Tray Sizing % Liquid Draw 14-204 Use Tray Vapour to Size 14-207 Tray Temperature Specification (Column) 2- 132 Trayed Sections See Column Sizing Utility. True and Pseudo Critical Properties See Critical Properties Utility. Tubes (Heat Exchanger) dimensions 4-113 heat transfer length 4-113 U UA LNG exchanger 4-178, 4-187 Upper bound See also ESTIM DRU final output User Properties Utility 14-231 User Property Specification (Column) 2-133 Utilities available utilities 14-4 Bad Data Elimination 14-35 boiling point curves 14-7 cold properties 14-17 column sizing 14-196 component curves 14-23 critical property 14-29 Data Reconciliation 14-35 dynamic depressuring See also Dynamic Depressuring 14-60 envelope 14-87 hydrate formation 14-126 Parameter Estimation 14-35 parametric 14-145 pipe sizing 14-172 property table 14-187 tray sizing 14-196 user properties 14-231 vessel sizing 14-235 Utility Data 5-192 V Value See also ESTIM DRU final output Valve 6-133 actuator 6-173 friction factor 6-170 holdup 6-171 manufacturer 6-138 nozzles 6-165 pipe contribution 6-169 sizing 6-137 sizing method 6-145 types 6-142 Vapor Flow Specification (Column) 2-134 Vapour Fraction Specification (Column) 2-134 Vapour Pressure Specifications (Column) 2- 134 Varbl See also ESTIM DRU final output variable navigator 1-35 Verify level See also ESTIM DRU initial problem parameters Vessel duty parameters 1-16 kettle chiller 1-20 kettle heat exchanger 1-20 kettle reboiler 1-20 Vessel Heater 1-17 Vessel Sizing Utility quick start 14-235 Vessels boot 10-26 features 10-13 geometry 10-23 heater type 1-16 holdup 10-49 liquid heater 1-17 nozzles 10-26 Vortoil G-liners 6-16 W Wave Flow (Pipe Segment) 6-60 Z zone 4-57 Zones cooler/heater 4-53 heat exchanger 4-116.c doadfamily.com EMail:cadserv21@hotmail.com cument is for study only,if tort to your rights,please inform us,we will delete www The I-12 I-12.c doadfamily.com EMail:cadserv21@hotmail.com cument is for study only,if tort to your rights,please inform us,we will delete





点击后进入安全下载页,再进行实际下载。下载链接有效期 24 小时,过期会自动刷新。